Errata in ISO 17208
This is the entry of the errata registry on ISO 17208-2:2019. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.
ISO 17208-2:2019, Clause 5 uncertainty band coverage
Section titled “ISO 17208-2:2019, Clause 5 uncertainty band coverage”- Location: Clause 5 (representative expanded uncertainties), printed p. 4.
- The print: “5 dB for the low frequency (10 Hz to 100 Hz) bands, 3 dB for the mid frequency (125 Hz to 16 000 Hz) bands, and 4 dB for the high frequency (>20 000 Hz) bands”.
- The problem: the 20 kHz one-third-octave band itself is left unassigned: the mid range ends at 16 kHz inclusive and the high range starts strictly above 20 kHz. ISO 17208-1:2016, from which clause 5 says the values are taken, prints the same three ranges with “≥20 000 Hz”, which closes the gap; Part 2 degraded the to a . The 20 kHz band is not a corner case for this document: ISO 17208-1 Table 1 requires the measurement to cover “20 000 Hz (minimum)” as its upper one-third-octave band. An earlier revision of this entry said “nothing covers 16 kHz to 20 kHz inclusive”, which is wrong at the lower end: 16 kHz is covered.
- Evidence: the two clauses side by side. Verified on PDF page 10 (printed p. 4) of ISO 17208-2:2019 and PDF page 22 (printed p. 16) of ISO 17208-1:2016.
- Library behaviour: applies the conservative 4 dB high-band value from the 20 kHz band upwards, following Part 1, with the gap documented.
- Status: unreported.
Created and maintained by José Manuel Requena PlensORCIDAbout the maintainerRelease notesChangelogAll projects