Source properties that are not errata

The errata registry also records properties of the published sources that look like defects and are not: a difference the source discloses itself, a rounding it shares with its family, a value that is right for a form of the material the other books do not describe. They are kept here so that a future reader does not “fix” the library to match them.

Section titled “Related source properties that are not errata”

Recorded here to prevent future “fixes” that would break agreement with the published sources:

  • Norton & Karczub 2e (2003), Appendix 4 A, the densities of polystyrene, polyurethane and PVC: the appendix prints , and kg/m, where Mechel and Bies print , and for the same names. The difference is not a lost digit. Each Norton & Karczub row also prints a Young’s modulus and a bulk speed, and the three satisfy to within a per cent, which describes the expanded or cellular form of the polymer; the other books describe the solid one. Neither page qualifies the bare name. Verified on PDF page 625 (printed p. 605). Registered here, and in ACCEPTED in scripts/check_solid_agreement.py, so that the low densities are not “corrected” to the solid polymer’s.

  • Norton & Karczub 2e (2003), Appendix 4 C, hydrogen and oxygen at 0 and 20 °C: each gas is printed with the same density at both temperatures, and kg/m, while its speed changes as it should and air, in the same table, drops from to over the same interval. It is not registered as an erratum because the table’s own columns do not settle it: puts these rows between and kPa, no further from an atmosphere than the carbon dioxide and steam rows. Verified on PDF page 626 (printed p. 606). The four states say so in their validity in PUBLISHED_FLUIDS, and the published catalogues page shows it on their density.

  • ISO 11546-1:1995 Annex A and Annex B: Figure B.1 is captioned “Source spectrum for an artificial sound source constructed according to the guidelines given in annex A”, while Annex A, which asks for a steel plate of 4 mm by 800 mm (approx.) by 300 mm (approx.), adds in its own last paragraph that “the length of the steel plate used for this measurement was 600 mm” and that a source built to the annex may give a different spectrum. The figure is therefore an illustration of a source a quarter shorter than the approximate length the annex prescribes, and the annex says so. Verified on PDF page 17 (printed p. 10) and PDF page 19 (printed p. 12) of ISO 11546-1:1995 as published in BS EN ISO 11546-1:2009. Not registered as an erratum because the standard discloses the difference itself; registered here so that ARTIFICIAL_SOURCE_EXAMPLE_LWA is not read as a property of an Annex A source.

  • ISO 7235:2003, Equations (10), (21) and (22): the ideal gas law is printed with and the absolute temperature written as . Neither is the accurate value (287.05 and 273.15). The offset alone puts a density 0.051 % high at 20 °C and the gas constant adds 0.017 % to that, for 0.069 % in all. This is a simplification and not a defect: the density it produces is used only in the dynamic pressure of Equations (16), (19) and (20), and both series of the pressure loss coefficient carry the same factor, so Equations (17) and (18) come out scaled by it rather than shifted, 0.069 % low, which is far under the uncertainty of a pressure-loss test and is what a result computed to the standard shows. The library keeps both printed constants, as ISO7235_AIR_GAS_CONSTANT_J_KG_K and ISO7235_ABSOLUTE_ZERO_OFFSET_K, so that a worked result can be reproduced as the standard gives it, and the conformance row “Normal air density (Eqs. (10), (21), (22))” records the size of the gap.

  • ISO 12354-1:2017 Table L.8 / ISO 12354-2:2017 Table G.8, first row: the row labelled “Int. wall 1/2 – Ext. wall 1/2” prints and (Part 2: ) , which is the assignment for a path leaving the external wall, the opposite of the direction the row’s own label gives. Read in the row’s direction the element carrying the path is the internal wall, so should be 360.0 and the perpendicular mass 219.0. It is a labelling slip and nothing else: the branch is the rigid-T corner branch , where only enters, so both assignments return the same 5.965 → 6.0 dB. The second row of each table, “Ext. wall 1/2 – Ext. wall 1/2”, is the through branch , where the sign of does matter, and it is labelled and populated consistently ( gives 9.006 → the printed 9.0). Verified on PDF page 89 (printed p. 83) of ISO 12354-1:2017 and PDF page 46 (printed p. 40) of ISO 12354-2:2017. Not registered as an erratum because no number depends on it; registered here so that a future reader does not “correct” the library’s per-path convention to match the printed row.

  • Francois-Garrison pure-water term: the two published cubics do not meet exactly at the 20 °C switch (a step of , 0.1 dB/km at 1 MHz). Inherent in the published coefficients.

  • Ainslie-McColm simplification: the paper’s “within 10 % of Francois-Garrison” claim is marginally exceeded at the extreme corners of its stated domain (10.4 % at −6 °C / 1 MHz; 12.3 % at 7 km depth). A property of the published fit; both transcriptions verified digit-for-digit.

  • CNOSSOS-EU Annex II 2.3, missing equation number: the railway section numbers its formulae (2.3.1), (2.3.2), (2.3.4), (2.3.5)…, with no (2.3.3) anywhere in Annex II. Verified on PDF page 17 (printed p. L 168/17) of Directive (EU) 2015/996:2015, where (2.3.2) and (2.3.4) sit one above the other. Nothing is missing from the method; only the numbering skips.

  • CNOSSOS-EU corrigendum of 2018, Table G-3 column codes: the corrigendum is reported to head the seven columns “B/S B/M B/H B/S B/M B/H B/H”, where the first three should read “M/S M/M M/H” and the last “W”, and Commission Delegated Directive (EU) 2021/1226 Annex point (20)(c) does replace that header with the corrected codes plus a new column D. It is left unregistered because the corrigendum itself is published only as HTML on EUR-Lex, so no printed page of it could be obtained here, and this registry does not record a claim about a printed symbol that has not been read off the page. The 2015 print of the same table, which was read, carries descriptive headers (“Mono-block sleeper on soft rail pad” and so on) and no defect.

  • Long, Architectural Acoustics 2e, Chapter 17, adjacent-table level: the restaurant example states that “at an adjacent table 3 m (10 ft) away, the direct field level from our conversation is about 54 dB”, where his own Eq. (17.50) with the and that yield his 60 dB at 1.2 m gives 52.5 dB. It is left unregistered because the intended reading cannot be established from the book: 54 dB is also what the same equation gives at 2.5 m (54.1 dB, and 2.5 m is the table spacing the next paragraph derives), and what a single 6 dB distance doubling from the rounded 60 dB would give, while the printed “3 m (10 ft)” is self-consistent in both units and is repeated in the preceding paragraph. speech_direct_level evaluates Eq. (17.50) as printed, so it returns 52.5 dB there; do not “correct” it toward 54 dB.

  • ICAO Annex 16 EPNL constant: the Annex’s rounded constant 13 for uniform 0.5 s records differs from the exact form by 0.0103 dB; the library uses the exact form, which the ETM’s integrated reference reproduces to five decimals.

  • Long Table 14.9 element rows: the worked duct-borne sheet of Chapter 14 was produced by a commercial program, as the text introducing it states, and several of its element rows do not follow from the tables printed beside them: the fan row (90/86/82/79/77/75/71/61 dB) is not what Eq. 13.1 gives with the Table 13.5 forward-curved constants at that duty (99/99/89/84/82/77/72/67 dB, and not a level shift of it), and the flexible-duct row (14/14/16/15/17/22/16/13 dB) is not the Table 14.4 entry for 12 in by 6 ft (3/5/10/15/17/16/9 dB). The library implements the printed equations and tables, and uses the sheet only for what it genuinely pins, the cascade arithmetic; its element rows are fed in as published in tests/noise_control/test_duct_path.py. The sheet’s own rounding is likewise not always self-consistent (supply row 3 prints a Sum of 49 dB at 500 Hz where , then a Combined consistent with 48), which is why the comparison runs at the 1 dB the printed sheet carries.

  • ISO 3747:2010 Table E.1, the accuracy-grade labels: the informative table of worked examples labels its three rows “0,5 (accuracy grade 1)”, “1,5 (accuracy grade 2)” and “3 (accuracy grade 3)”, while the normative Table 2 of this part gives = 4.0 dB for survey grade 3 and the scope of ISO 3747 covers grades 2 and 3 only. It is the ISO 3740 family’s shared illustration, not a statement about this method: ISO 3744:2010 Table H.1 prints the identical table, rows, labels and cells alike, and ISO 3744 covers grade 2 only. Verified on PDF page 42 (printed p. 33) and PDF page 27 (printed p. 18) of BS EN ISO 3747:2010. The library reads from the normative Table 2 (1.5 dB and 4.0 dB, conformance check “ISO 3747:2010 Table 2 / Eq. 22”) and uses Table E.1 only for its = 1.6 / 2.5 / 4.3 row against = 1.5 dB, where the two tables agree. Do not “correct” the 3 dB row to 4.0 dB: it belongs to the family’s illustration, not to this part’s Table 2.

  • ISO 3747:2010 Annex C, = 296 K: the annex prints the reference temperature of the radiation-impedance correction as 296 K beside a reference condition of 23.0 °C, which is 296.15 K, so at exactly the reference conditions dB rather than zero. ISO 3741:2010 clause 9.1.4 and ISO 3744:2010 print the same = 296 K, so it is the family’s rounding and not a misprint of one part; the library keeps 296 K in the shared C2 of _sound_power_reverberation.py and pins the residual (conformance check “ISO 3747:2010 Annex C”). Do not “correct” it to 296.15 K.

  • ISO 3747:2010 Eq. (14), the single-event background margin: subtracts a time-averaged background level from a time-integrated single event level, asking only that both be measured over the same integration time . The difference is a true margin for = 1 s; for a longer the background holds dB more energy over the event’s interval (clause 3.4, NOTE 1). ISO 3741:2010 Eq. (25) and ISO 3744:2010 clause 8.3.4 print the same line, verified on PDF page 23 (printed p. 14) of BS EN ISO 3747:2010 and on the corresponding pages of the two siblings, so it is the family’s convention and is not registered against one part. The library applies Eq. (14) as printed by default and offers integration_time on sound_energy_in_situ to carry the background to the event’s interval first.

  • ISO 5136:2003, clause 5.3.4.3, the sign of Equation (8): the clause says the corrections of the nose cone and the foam ball “are estimated to be negative and of small magnitude”, and then prints dB, which is positive whenever : at the 20 m/s the nose cone is allowed, with = 340 m/s, dB on the outlet side and dB on the inlet side. The equation’s sign is the one the convected plane wave gives, the energy flux of a wave travelling with the flow being times , so for a given pressure the power is higher downstream and lower upstream. It is not registered as an erratum because the closing sentence of the same paragraph reconciles the two: “With this simplification, the sound power level obtained by using the nose cone or foam ball is expected to be higher than the true sound power level.” The negative correction is the modal one, which is unavailable and is dropped; Equation (8) is the convective part that is kept, and the standard says in the same breath that what is left biases high. Read on PDF page 29 (printed p. 19) of ISO 5136:2003. Registered here so that nobody “corrects” the sign of Equation (8), which flow_modal_correction implements as printed and test_eq8_omnidirectional_shields in tests/emission/test_sound_power_in_duct.py pins.

  • ISO 11820:1996 Table 1 and ISO 10847:1997 Table 3, two background corrections that disagree: both tables take a margin between the level with the source and the level without it and answer with a correction in decibels, and they answer differently. ISO 11820 refuses under 3 dB and then takes off 3, 2, 2, 1, 1, 1, 0.5 and 0.5 dB up to a margin of 10 dB; ISO 10847 refuses under 4 dB and then takes off 2, 2, 1, 1, 1 and 1 dB up to the same margin. At a margin of 9 dB the first takes off 0.5 dB and the second 1 dB. The signs differ as well, because the ISO 11820 column reads “corrections to be subtracted from sound pressure level measured with sound source operating” and prints its values positive, while the ISO 10847 column reads “correction to be made to the measured sound pressure level” and prints them negative. Neither is an erratum: they are two committees’ tabulations of the same physical subtraction, rounded differently and written from opposite ends. Read on PDF page 13 (printed p. 5) of EN ISO 11820:1996 and on PDF page 11 (printed p. 7) of ISO 10847:1997. The library keeps them apart as silencer_background_correction and barrier_background_correction, each with its own sign convention and its own refusal, and a conformance check holds them against each other at the margin where they part. Do not merge them into one helper.

  • Beranek & Mellow 2e Table 7.1, the Delany and Bazley column: the table prints to = 0.0511, 0.0768, 0.0858, 0.175 where DELANY_BAZLEY_COEFFICIENTS holds , , , = 0.0571, 0.087, 0.0978, 0.189 from Bies 5e Table D.1. The four amplitudes are 8 % to 14 % apart and the ratios are not constant (1.117, 1.133, 1.140, 1.080), so no single scale factor relates them. The reason is the variable. Beranek’s Equation (7.11), printed above the table on the same page, is written in with positive exponents, while Delany and Bazley, and Bies after them, write with negative ones. The two forms differ by exactly , and solving row by row gives = 1.16, 1.19, 1.21, , which is the density of air in every row; carrying the conversion the other way with = reproduces the four printed amplitudes to 1.4 %, 0.4 %, 1.5 % and 2.1 %. The exponents agree independently: Beranek prints to = 0.75, 0.73, 0.70, 0.59 against , , , = 0.754, 0.732, 0.700, 0.595, the same numbers to two decimals. The control is the table’s other column: Miki’s variable is and carries no density, and Beranek’s Miki column, 0.070, 0.107, 0.109, 0.160 with 0.632, 0.632, 0.618, 0.618, agrees digit for digit with the constants miki is written from. Verified on PDF page 352 (printed p. 349) of Beranek & Mellow, Acoustics: Sound Fields, Transducers and Vibration 2e (2019), and on PDF page 757 (printed p. 728) of Bies, Hansen & Howard, Engineering Noise Control 5e (2017). Neither book is in error: they print one regression in two variables. The library follows Delany and Bazley through Bies, in , so its amplitudes must not be “corrected” towards Beranek’s, which would apply the air density a second time.

  • IEC 60268-7:2010, “the standard reference frequency” beside the standard measuring frequency of 500 Hz: 7.2 b) sets “the standard measuring frequency” at 500 Hz, and the NOTE of 8.3.3.1 gives the reason for the coupler, “to avoid the effects of diaphragm resonance, leakage and standing waves”. The part also names “the standard reference frequency” (8.3.6.2 b), 8.6.3.1, 8.6.4.1, 8.7.2.1, 8.9.1 a)) and never defines it; IEC 60268-1:1985, which Clause 2 cites, does, in Clause 3: “If a measurement relates to a reference frequency, then, in the absence of a clear reason to the contrary, this shall be the standard reference frequency of 1 000 Hz”. The comparison methods begin and end their test sequence on “the band centred on 1 kHz” (8.6.3.2 c), 8.6.4.2 c)), while Formula (1) of the ear canal method prints its own reference band, 500 Hz. The two terms are not always kept apart: 8.7.2.1 specifies the harmonic distortion “at the standard reference frequency” and 8.7.2.2 b) applies the voltage “at the standard measuring frequency”. It is not registered as an erratum because each clause can be read as printed. Read on PDF page 11 (printed p. 9) of IEC 60268-1:1985 and on PDF pages 17, 21, 23, 26 to 29 and 31 (printed pp. 15, 19, 21, 24 to 27 and 29) of IEC 60268-7:2010. The library refers the comparison responses of field_comparison_response to 1 000 Hz by default, and the ear canal response and the coupler’s relative response to 500 Hz; the conformance row “IEC 60268-7:2010 8.6.3.1 with IEC 60268-1:1985 Clause 3” pins the default. Do not move the comparison responses to 500 Hz for uniformity.