Errata in Long (2014)

These are the 4 entries of the errata registry on Long (2014), in the order the registry lists them. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.

Long, Architectural Acoustics 2e (2014), Eq. (18.24) (sign of the microphone directivity)

Section titled “Long, Architectural Acoustics 2e (2014), Eq. (18.24) (sign of the microphone directivity)”
  • Location: Chapter 18, “Multiple Open Microphones”, Eq. (18.24) (printed p. 699), the gain-before-feedback stability criterion generalised to several open microphones.
  • The print: , with the microphone directivity index entering the right-hand side with a plus sign.
  • The problem: Eq. (18.24) is the number-of-open-microphones generalisation of Eq. (18.20) (printed p. 698), which reads and which follows in turn from the oscillation condition Eq. (18.19), , obtained by substituting the feedback-loop gain (Eq. (18.18)) into (Eq. (18.16)). Setting makes , so Eq. (18.24) must reduce to Eq. (18.20) and does not. The sign matters physically: is “usually negative” in Long’s own definition (about to -3 dB for a cardioid pointed at the talker), so as printed a directional microphone would cost gain before feedback instead of buying it, inverting the chapter’s own conclusion that “it is prudent to incorporate a cardioid or hypercardioid microphone into a system”.
  • Evidence: the printed equation reads , against two pages earlier, where the same position holds a minus. (An earlier revision of this entry quoted the pdftotext extraction, Z S þ L HM þ DL nom L HL þ D M ðqÞ 10, in which þ is the ligature this PDF uses for ”+” and every minus sign has been dropped entirely; that extraction cannot distinguish a plus from a minus and should never have been the evidence.) Verified on PDF page 697 (printed p. 699) and PDF page 696 (printed p. 698) of Long, Architectural Acoustics 2e (2014). The minus sign is the one that reproduces Long’s own worked special cases at : with , Eq. (18.21) gives (an omnidirectional microphone 4 dB below the average audience level), and Eq. (18.22) gives for a cardioid at . Neither special case is recoverable from the printed Eq. (18.24).
  • Library behaviour: feedback_stability in sound_reinforcement.py implements the sign of Eq. (18.20), with a note at the criterion. Both of Long’s special cases are pinned by regression tests (tests/electroacoustics/test_sound_reinforcement.py) and by the conformance checks “Long, Architectural Acoustics 2e, Eq. (18.21)” and “Eq. (18.22)”.
  • Status: unreported (textbook rather than a standard, so non-normative).

Long, Architectural Acoustics 2e (2014), Eq. (17.53) (constant of the communication bound)

Section titled “Long, Architectural Acoustics 2e (2014), Eq. (17.53) (constant of the communication bound)”
  • Location: Chapter 17, “Restaurant Design”, Eq. (17.53) (printed p. 666), the minimum absorption per occupied table for adequate cross-table communication.
  • The print: .
  • The problem: the bound is Eq. (17.52), , solved for at the stated threshold , which gives . With the the chapter uses for a talker, that constant is 6.3130, not 6.33. The gap is , i.e. the last printed digit: 6.33 is what returns if is carried coarsely as 0.252 instead of 0.251 19. This is graded as a rounding-level discrepancy rather than a structural error of the formula, since the formula itself is confirmed by its companion (below) and no consistent alternative assumption reproduces 6.33 (it would require ).
  • Evidence: the immediately following Eq. (17.54) is the same closed form at the privacy threshold , and its printed constant 3.16 is exactly what gives, confirming both the formula and . Only the -6 dB constant is off. What does not discriminate is Long’s prose one paragraph later, “at least 6.3 or more square meters (68 sq ft) of absorption per table”: is and is , so both print as 68 sq ft, and both round to . An earlier revision of this entry offered that conversion as corroboration. Verified on PDF page 665 (printed p. 666) of Long, Architectural Acoustics 2e (2014).
  • Library behaviour: absorption_per_table in _crowd_noise.py computes the bound from Eq. (17.52) rather than hardcoding either constant, so both bounds stay mutually consistent; the 6.313 value and the printed 3.16 are pinned by regression tests (tests/room/test_crowd_noise.py) and the 3.16 constant by the conformance check “Long, Architectural Acoustics 2e, Eq. (17.54)”.
  • Status: unreported (textbook rather than a standard, so non-normative); graded as a rounding discrepancy rather than a structural defect.

Long, Architectural Acoustics 2e (2014), Table 14.7 (round elbow rows)

Section titled “Long, Architectural Acoustics 2e (2014), Table 14.7 (round elbow rows)”
  • Location: Chapter 14, Table 14.7, “Insertion Loss of Round Elbows” (printed p. 541), indexed by the frequency-width product (kHz times inches).
  • The print: four rows only: → 0 dB; → 1 dB; → 2 dB; → 3 dB.
  • The problem: the band has no row at all, so the table jumps from straight to . A duct-borne calculation lands in that band routinely: a elbow at 500 Hz has .
  • Evidence: the same data adapted from the same ASHRAE source appear in Bies, Hansen & Howard, Engineering Noise Control 5e, Table 8.11, indexed by (). Its round-elbow column has six rows, 0/1/2/3/3/3, and gives 3 dB for , which is exactly the band Long omits. Long’s four rows map onto Bies’ six as follows: the first three agree entry for entry, the fourth (, 3 dB) legitimately merges Bies’ two identical top rows, and the band with no row is Bies’ fourth. An earlier revision of this entry said that “Tables 14.5 and 14.6 both carry six rows” and that “the other five rows of the two tables agree entry for entry”; on the page, Table 14.5 carries six rows and Table 14.6 five (it merges the same two identical top bands, legitimately), and Table 14.7 prints four, so neither count is right. Verified on PDF page 542 (printed p. 541) and PDF page 541 (printed p. 540) of Long, Architectural Acoustics 2e (2014).
  • Library behaviour: elbow_insertion_loss in hvac.py carries the six-row round column with 3 dB in the missing band, pinned by test_elbow_tables_by_frequency_width_product (tests/noise_control/test_hvac_long.py).
  • Status: unreported (textbook rather than a standard).

Long, Architectural Acoustics 2e (2014), Eq. 13.28 (units of U_G)

Section titled “Long, Architectural Acoustics 2e (2014), Eq. 13.28 (units of U_G)”
  • Location: Chapter 13, Eq. 13.28 (printed p. 521), the normalised pressure-drop coefficient of the diffuser sound-power model.
  • The print: the nomenclature under the equation gives “U_G = flow velocity prior to the diffuser (ft/min)” and, on the next line, ”= Q/(60·S_G) (for Q in cfm)”.
  • The problem: the two statements contradict each other. in divided by is a velocity in ft/s, not ft/min, and only the ft/s reading makes the constant right: with is , which is the standard velocity-pressure relation only when is converted from ft/s. Read as ft/min the coefficient comes out 3600 times too small. Eq. 13.27 itself declares in ft/s, so the “(ft/min)” label under Eq. 13.28 is the odd one out.
  • Evidence: dimensional check of ; reconstruction of the constant from the velocity-pressure relation; and the peak frequency. What does not discriminate is the overall level: Eq. 13.27 carries , and substituting Eq. 13.28 makes the velocity cancel identically, . For the Table 14.9 supply diffuser (, cfm, in w.g.) both readings therefore return the same . An earlier revision of this entry claimed that the ft/min reading “misses it by 100 dB”, which is arithmetically impossible for a quantity that does not depend on the velocity at all. What does discriminate is Eq. 13.32, , which is the only other place enters: read in ft/s the approach velocity is and the peak falls at 63.4 Hz, i.e. in the 63 Hz octave, so the Eq. 13.31 shape puts 33.4 dB in that band against the printed 33; read in ft/min it is , the peak moves to 3 806 Hz, and the same shape puts -8.2 dB in the 63 Hz band. Verified on PDF page 522 (printed p. 521) of Long, Architectural Acoustics 2e (2014).
  • Library behaviour: diffuser_sound_power in hvac.py reads in ft/s internally (SI at the interface), with the Table 14.9 row pinned by test_diffuser_sound_power_reproduces_the_table_14_9_row (tests/noise_control/test_hvac_long.py) and the conformance check “Long 2e Eqs. 13.27-13.33”.
  • Status: unreported (textbook rather than a standard).