Skip to content

Errata in ISO 3095

These are the 3 entries of the errata registry on ISO 3095:2013, in the order the registry lists them. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.

ISO 3095:2013, Table G.1 (the standard uncertainty of the 25 m microphone distance printed as 0.004 dB)

Section titled “ISO 3095:2013, Table G.1 (the standard uncertainty of the 25 m microphone distance printed as 0.004 dB)”
  • Location: Annex G (informative), Table G.1, the row, printed p. 49.
  • The print: “for a microphone distance of 25 m: ±0,07 dB” in the Uncertainty interval column and “for a microphone distance of 25 m: 0,004 dB” in the Standard uncertainty column; the 7,5 m line of the same row prints ±0,23 dB and 0,13 dB.
  • The problem: G.3 derives every standard uncertainty of the table from its interval as (Formula G.2), and so does every other row: ±0.25 dB gives 0.14 dB, ±0.44 dB gives 0.25 dB, and the 7.5 m line of this row gives dB, as printed. For ±0.07 dB the formula gives dB. The printed 0.004 dB is ten times smaller, a digit zero too many after the decimal comma; the cell should read 0.04 dB.
  • Evidence: Table G.1 read on PDF page 55 (printed p. 49) and Formula G.2 on PDF page 54 (printed p. 48) of ISO 3095:2013 (third edition, 2013-08-01).
  • Library behaviour: Table G.1 is not published by the library; pass_by_uncertainty takes each input as a value and its standard uncertainty, and metrology.rectangular(0.0, 0.07) gives the 0.040 dB of Formula G.2. The conformance check “ISO 3095:2013 Table G.1” holds the eighteen rectangular rows whose print Formula G.2 reproduces and leaves this cell out. No change was required.
  • Status: unreported.

ISO 3095:2013, Table G.1 against Table G.2 (the ground-level uncertainty at 7.5 m printed as 0.55 dB in one and 0.30 dB in the other)

Section titled “ISO 3095:2013, Table G.1 against Table G.2 (the ground-level uncertainty at 7.5 m printed as 0.55 dB in one and 0.30 dB in the other)”
  • Location: Annex G (informative), the row of Table G.1, printed p. 49, and the row of Table G.2, printed p. 51.
  • The print: Table G.1 gives the interval “[0 dB; 1,03 dB]” and the standard uncertainty “0,55 dB” with ” = 0,515 dB” for a microphone at 7,5 m. Table G.2, the example of G.6 for a standstill measurement whose ground “over a distance of 7,5 m varies between 0 and 2 m below to the top of the rail”, uses the same correction 0,515 dB with a standard uncertainty of 0,30 dB.
  • The problem: footnote a of Table G.1 treats an unsymmetrical range as a symmetric one about its mean, which is where the correction dB comes from, and Formula G.2 then gives the half width over : dB, the 0.30 dB of Table G.2. The 25 m line of the same quantity follows that arithmetic, dB as printed. The 0.55 dB of Table G.1 is neither the half width nor the whole width over (0.59 dB); the cell should read 0.30 dB. The two tables also differ on the distance at 7.5 m, where Table G.1 prints 0.13 dB and Table G.2 carries 0.06 dB without saying where that value comes from; the combined 0.83 dB of Table G.2 needs its 0.06 dB (0.13 dB would give 0.84 dB), so that difference is recorded here and not corrected.
  • Evidence: Table G.1 read on PDF page 55 (printed p. 49), Formula G.2 and footnote a on PDF page 54 (printed p. 48), and Table G.2 on PDF pages 56 and 57 (printed pp. 50 and 51) of ISO 3095:2013 (third edition, 2013-08-01).
  • Library behaviour: the conformance checks “ISO 3095:2013 Table G.2” feed pass_by_uncertainty the thirteen rows of Table G.2 as printed, 0.30 dB and 0.06 dB included, and reproduce its 55.68 dB, 0.83 dB and 1.66 dB. No change was required.
  • Status: unreported.

ISO 3095:2013, Table G.1 (the wind screen interval printed with its bounds out of order)

Section titled “ISO 3095:2013, Table G.1 (the wind screen interval printed with its bounds out of order)”
  • Location: Annex G (informative), Table G.1, the row, printed p. 49.
  • The print: “Damping of the wind screen”, interval “[0,12 dB; 0 dB]”, standard uncertainty “0,03 dB” and ” = 0,06 dB”.
  • The problem: footnote a writes an unsymmetrical range as , and the four other rows that use one write the lower bound first: ”[−0,21 dB; 0 dB]” for the distortion factor of the calibrator, ”[−1,5 dB; 1 dB]” for impulses, and “[0 dB; 1,03 dB]” and “[0 dB; 0,33 dB]” for the ground level at 7.5 m and at 25 m. Printed as it is, the wind screen interval has its lower bound above its upper one, and is empty. It should read either [−0.12 dB; 0 dB], a range that lowers the reading written the way the distortion row writes its own, whose mean value correction footnote a says “increases the average sound level”, or [0 dB; 0.12 dB], written the way the ground-level rows write theirs. Both readings give the printed 0.03 dB and 0.06 dB, so the table does not say which one was meant.
  • Evidence: Table G.1 and its footnote a read on PDF page 55 (printed p. 49) and on PDF page 54 (printed p. 48) of ISO 3095:2013 (third edition, 2013-08-01).
  • Library behaviour: the library reads no interval of Table G.1; the conformance check “ISO 3095:2013 Table G.1” uses the half width 0.06 dB and the Table G.2 checks the correction and uncertainty as printed. No change was required.
  • Status: unreported.
Edit page

Published , updated