Errata in IEC 60268
These are the 15 entries of the errata registry on IEC 60268-1:1985, IEC 60268-3:2013, IEC 60268-16:2011 and IEC 60268-7:2010, in the order the registry lists them. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.
IEC 60268-1:1985, Appendix A, Figure A1 (last shunt capacitor printed as 41.47 nF)
Section titled “IEC 60268-1:1985, Appendix A, Figure A1 (last shunt capacitor printed as 41.47 nF)”- Location: Appendix A, “Noise weighting network and quasi-peak meter”, Figure A1 “Weighting network” (printed p. 29), drawing 0641/85. The French print of the same artwork (printed p. 28) carries the same value as “41,47 nF”.
- The print: the last shunt capacitor of the ladder, the one across the 600 Ω amplifier input, is labelled 41.47 nF.
- The problem: it should be 31.47 nF, which is what ITU-R BS.468-4 Figure 1a prints for the same network. Every other element of Figure A1 matches BS.468-4 Figure 1a exactly: 600 Ω source, 13.85 nF, 12.88 mH, 26.82 nF, 33.06 nF, 9.21 nF, 26.49 mH and Z = 600 Ω. The intended reading is not in doubt, because the document contradicts itself: evaluated against Table AI, printed two pages earlier in the same annex, the 31.47 nF ladder reproduces all 21 rows to a maximum of 0.050 dB and violates no tolerance, while the 41.47 nF ladder is out by up to 2.252 dB (at 31 500 Hz) with a root-mean-square error of 1.055 dB and breaks Table AI’s own tolerance column at seven frequencies, every one from 8 000 Hz to 20 000 Hz: −0.40 dB against ±0.40 at 8 kHz, −0.74 against ±0.60 at 9 kHz, −1.16 against ±0.80 at 10 kHz, −1.85 against ±1.20 at 12.5 kHz, −1.98 against ±1.40 at 14 kHz, −2.05 against ±1.60 at 16 kHz and −2.12 against ±2.00 at 20 kHz. Sweeping the capacitor to minimise the error against Table AI lands on 31.4798 nF.
- Evidence: the two ladders evaluated independently by an ABCD chain product over the seven printed reactive elements between the printed 600 Ω source and load, normalised at 1 kHz, and compared row by row with Table AI and its tolerance column. Neither Amendment 1:1988 (which replaces Table AII only) nor Amendment 2:1988 (which replaces sub-clause 12.1, on producing a uniform alternating magnetic field) touches Figure A1, so the misprint stands in the current document as amended. Verified on PDF page 31 (printed p. 29) and PDF page 29 (printed p. 27), which carries Table AI, of IEC 60268-1:1985, and on PDF page 1 (printed p. 1) of Recommendation ITU-R BS.468-4.
- Library behaviour: unaffected. The weighting network is built from the
BS.468-4 Figure 1a component values in
filters/weighting.py, with 31.47 nF, and the Table 1 rows are the oracle. The entry matters because IEC 60268-3:2013 sub-clause 14.12.11 sends a reader to “a weighting network complying with Appendix A of IEC 60268-1”, so a clean-room implementation started from IEC 60268-3 lands on the wrong capacitor. - Status: unreported.
IEC 60268-1:1985, Appendix A, Table AII (lower-limit row slipped one column)
Section titled “IEC 60268-1:1985, Appendix A, Table AII (lower-limit row slipped one column)”- Location: Appendix A, Table AII, the tone-burst dynamic characteristic of the quasi-peak meter, “Limited values — lower limit” row (printed p. 31).
- The print: the lower limit (%) row reads
13.5 | 22.4 | 34 | 41 | 44 | 44 | 50 | 68for the 1, 2, 5, 10, 20, 50, 100 and 200 ms columns, while the (dB) row printed immediately beneath it reads−17.4 | −13.0 | −9.3 | −7.7 | −7.1 | −6.0 | −4.7 | −3.3. - The problem: the 50 ms and 100 ms cells contradict their own dB cells.
−6.0 dB is 50.1 %, not 44 %, and −4.7 dB is 58.2 %, not 50 %. The percentage
row has slipped one column to the right from 50 ms onwards, carrying the
20 ms and 50 ms values into the two cells after them; the dB row and the
200 ms cell stayed where they belong. ITU-R BS.468-4 Table 2 prints
... | 44 | 50 | 58 | 68for the same four columns. - Evidence: the two rows of the same table read against each other, and
against the corresponding row of ITU-R BS.468-4 Table 2. Corrected by
Amendment 1:1988-01, whose English sheet is headed “Page 31 / Replace
Table AII by the following:” and prints the lower limit row as
13.5 | 22.4 | 34 | 41 | 44 | 50 | 58 | 68, matching BS.468-4; every other cell of the replacement table is identical to the base print, so this row is the entire substantive content of the amendment. Verified on PDF page 33 (printed p. 31) of IEC 60268-1:1985, on PDF page 3 (printed p. 3) of IEC 60268-1:1985 Amendment 1:1988, and on PDF page 4 (printed p. 4) of Recommendation ITU-R BS.468-4. - Library behaviour: unaffected. The eleven acceptance windows are
transcribed from BS.468-4 Tables 2 and 3 in
tests/reference_data/, which agree with the amended IEC table. Recorded because the unamended base document is the one a reader is likely to hold, and it widens the 50 ms and 100 ms acceptance windows by 1.1 dB and 1.3 dB at the bottom. - Status: unreported (corrected by the issuing body in 1988).
IEC 60268-1:1985, Appendix A, Table AI (16 000 Hz tolerance printed as ±1.65)
Section titled “IEC 60268-1:1985, Appendix A, Table AI (16 000 Hz tolerance printed as ±1.65)”- Location: Appendix A, Table AI, the tolerance column, 16 000 Hz row (printed p. 27; the French Tableau AI on printed p. 26 prints the same value).
- The print:
±1.65 1). - The problem: ITU-R BS.468-4 Table 1 and AES17-2015 Table 1 both print ±1.6 for the same row, and the table’s own footnote 1) is what settles it: the marked tolerances “are obtained by a linear interpolation on a logarithmic graph on the basis of values specified for the frequencies used to define the mask, i.e. 31.5 Hz, 100 Hz, 1 000 Hz, 5 000 Hz, 6 300 Hz, and 20 000 Hz”. Interpolated on that rule between (6 300 Hz, 0 dB) and (20 000 Hz, ±2.0 dB), 16 000 Hz gives 1.6137 dB, which rounds to 1.6 at one decimal and to 1.61 at two. No rounding of the rule produces 1.65, and no alternative anchor pair does either: taking the 6 300 Hz to 31 500 Hz line instead gives 1.6216 dB. The value is also anomalous within its own column, which is quoted to one decimal everywhere else.
- Evidence: the footnote rule applied to all 14 marked rows of the same column, which reproduces every one of them (63 Hz 1.400, 200 Hz 0.8495, 400 Hz 0.6990, 800 Hz 0.5485, 3 150 and 4 000 Hz 0.5000, 7 100 Hz 0.2070, 8 000 Hz 0.4136, 9 000 Hz 0.6175, 10 000 Hz 0.7999, 12 500 Hz 1.1863, 14 000 Hz 1.3825, 31 500 Hz 2.7865) and 16 000 Hz alone disagrees with what is printed. Not corrected by Amendment 1:1988 or Amendment 2:1988. Verified on PDF page 29 (printed p. 27) of IEC 60268-1:1985 and on PDF page 2 (printed p. 2) of Recommendation ITU-R BS.468-4.
- Library behaviour: none needed. The tolerance mask is taken from BS.468-4 Table 1, and the realised digital curve is held to a far tighter bound than the mask anyway: the mask governs a measuring instrument comprising the amplifier and the network, not a filter’s departure from the nominal curve.
- Status: unreported.
IEC 60268-3:2013, clause 14.12.9.2 f) (DIM denominator)
Section titled “IEC 60268-3:2013, clause 14.12.9.2 f) (DIM denominator)”- Location: clause 14.12.9.2, item f) (printed p. 39), the formula for the dynamic intermodulation distortion .
- The print: .
- The problem: the denominator is one of the nine terms of its own numerator. Table 2 of the same clause (printed p. 38) defines as the intermodulation component at , and item d) defines as exactly those components, so the sum runs over and includes . Meanwhile the defining clause 14.12.9.1 states the ratio of the r.m.s. sum of the Table 2 intermodulation product voltages “to the amplitude of the output voltage at the frequency f_s”, i.e. the 15 kHz sine component , the Otala convention, and item d) measures “the amplitudes of the sinusoidal signal ” precisely so that it can be used, which the f) formula then never does. The denominator should be . An earlier revision of this entry said that “U2 is used throughout 14.12 for the total output voltage”; that is false, in both the English and the French print.
- Evidence: Table 2, item d) and item f) read together in both language columns of the bilingual edition; the historical DIM literature (Otala) defines the ratio to the sine amplitude. Verified on PDF page 41 (printed p. 39), PDF page 40 (printed p. 38), which carries Table 2, and PDF page 102 (printed p. 100), which carries the same item f) in the French column, of IEC 60268-3:2013.
- Library behaviour: follows the 14.12.9.1 definition (reference = the
output amplitude at ), with a code comment at the reference measurement
in
distortion.py. - Status: unreported.
IEC 60268-16:2011, Table M.1 (the beta row states the wrong redundancy term)
Section titled “IEC 60268-16:2011, Table M.1 (the beta row states the wrong redundancy term)”- Location: Annex M, Table M.1 “Example calculation”, step 4, the row labelled “Sum of beta* = beta weighting” (printed p. 67), directly below the matching alpha row.
- The print: the label reads , and the seven cells of the row read 0,059 | 0,052 | 0,045 | 0,008 | 0,037 | 0,081 | 0,000, summed on the next page as .
- The problem: the label and the cells state different quantities, and the label is the one that is wrong. Clause A.5.6 of the same edition (printed p. 47) defines the index as : the redundancy term is the geometric mean of two adjacent bands, not the band’s own . Read against the table’s own MTI row, gives 0.062 | 0.051 | 0.044 | 0.008 | 0.036 | 0.076, summing to 0.277, which disagrees with five of the six printed cells and with the printed total. reproduces all six cells and the 0.282 total. The seventh cell is not part of either reading: the redundancy sum stops at because the 8 kHz band has no band above it to pair with, so its 0.000 is the placeholder of a column with no redundancy partner, not a term. The alpha row above it, labelled the same way, is correct, because there the label and A.5.6 do agree.
- Evidence: both readings recomputed from the table’s own step 4c MTI row and compared cell by cell with the printed row and with its printed total; A.5.6 read against the label. The defect does not move this example’s answer, since and both print as the STI 0.76 the table ends on, which is how a label contradicting the normative formula survives a worked example. Verified on PDF page 69 (printed p. 67) and PDF page 49 (printed p. 47) of IEC 60268-16:2011.
- Library behaviour: implements A.5.6 with the redundancy term as printed
there, in
_index_from_corrected_mtf; the pairwise weighting-factor test of A.2.2 pins it independently, and the conformance rows “IEC 60268-16:2020 A.2.2” and “IEC 60268-16:2011 Annex M” both read the index it produces. - Status: unreported.
IEC 60268-16:2011, Table M.1 (I_k tabulated a million times its neighbours)
Section titled “IEC 60268-16:2011, Table M.1 (I_k tabulated a million times its neighbours)”- Location: Annex M, Table M.1, the row “Combined squared sound pressure , MPa” of step 2 (printed p. 64) and of step 3 (printed p. 65), read with the and rows below it.
- The print: for the 77,9 dB signal of the 125 Hz band, step 2 prints = 61,7, and four rows below it prints = 40 000 for the 46 dB reception threshold of the same band.
- The problem: two defects in one row. The unit is impossible: at 77.9 dB re 20 µPa the squared sound pressure is , so the cell cannot be 61.7 MPa under any reading of the prefix. What the row actually tabulates is the dimensionless intensity ratio divided by . And that divisor is not applied to the two quantities the standard adds to in the very next rows: and are tabulated as the plain ratio, 40 000 being rounded, undivided. A reader who forms from the cells as printed understates its first term by . The printed “adjustment to remove masking and threshold” row is the check: 1.019 at 500 Hz is only once is restored to 26 305 192; formed from the cells as printed the same expression reads 19 279.
- Evidence: every cell of both rows recomputed as from the combined levels printed above them, and every cell of the and rows recomputed as and ; the first set reproduces at of the computed value and the second two at . Verified on PDF page 66 (printed p. 64) and PDF page 67 (printed p. 65) of IEC 60268-16:2011.
- Library behaviour: carries all three quantities on one scale, the plain
ratio to , in the correction of
sti.py; the transcription intests/reference_data/keeps the printed cells verbatim and names the it rescales them by, and the conformance row “IEC 60268-16:2011 Annex M” reads the adjustment they feed. - Status: unreported.
IEC 60268-16:2011, Table M.1 (step 3 I_am,k at 250 Hz)
Section titled “IEC 60268-16:2011, Table M.1 (step 3 I_am,k at 250 Hz)”- Location: Annex M, Table M.1, step 3, the row, 250 Hz column (printed p. 65).
- The print: 2 850 000, the same value as the 500 Hz cell beside it.
- The problem: the cell does not round from the quantity it names. With the operational levels printed two rows above, at 250 Hz is the auditory masking factor of the 125 Hz band times that band’s combined intensity, , which at the three significant figures the row is printed to reads 2 860 000. The 500 Hz cell is correct: its 2 852 252 does print as 2 850 000. The two cells are reproduced together only by carrying the rounded of the row above instead of the factor itself, and step 2 shows that is not what the table does, since its two corresponding cells are printed apart, as 508 000 and 507 000, which only the unrounded factor gives.
- Evidence: both cells recomputed from the printed operational speech and noise levels, and the step 2 pair recomputed the same way as a control. The defect changes nothing downstream: the masking and threshold correction of the band is 0.985552 with the correct value against 0.985596 with the printed one, and the row prints 0.986 either way. Verified on PDF page 67 (printed p. 65) and PDF page 66 (printed p. 64) of IEC 60268-16:2011.
- Library behaviour: computes from the unrounded masking factor.
The transcription in
tests/reference_data/keeps the printed cell and the testtest_annex_m_step3_masking_intensity_at_250_hz_is_the_printed_erratumasserts the computed value against 2 858 804 and against the print, so the one cell of the table that is not an oracle cannot quietly become one. - Status: unreported.
IEC 60268-7:2010, 8.7.3.3, Formula (3) ( for the product at 460 Hz)
Section titled “IEC 60268-7:2010, 8.7.3.3, Formula (3) (U470 for the product at 460 Hz)”- Location: 8.7.3.3 c), Formula (3), printed p. 28.
- The print: "", one paragraph after item b), which reads “the third-order components are at 460 Hz and 740 Hz”.
- The problem: the test signal of 8.7.3.2 is the pair 70 Hz and 600 Hz, so the third-order modulation products are at Hz, 460 Hz and 740 Hz, as item b) says. No product of the two tones falls at 470 Hz: the subscript of the first voltage should read 460.
- Evidence: item b) and Formula (3) on PDF page 30 (printed p. 28) of IEC 60268-7:2010, Edition 3.0.
- Library behaviour:
headphone_modulation_signalgenerates the 70 Hz and 600 Hz pair, andmodulation_distortionreads the third-order products at 460 Hz and 740 Hz; the conformance row of 8.7.3.3 b) pins the four product frequencies. - Status: unreported.
IEC 60268-7:2010, 8.7.4.2 c), Formula (5) (a closing parenthesis with no opening one)
Section titled “IEC 60268-7:2010, 8.7.4.2 c), Formula (5) (a closing parenthesis with no opening one)”- Location: 8.7.4.2 c), Formula (5), printed p. 29.
- The print: "".
- The problem: a brace opens before and a parenthesis closes after that was never opened, so the print leaves open whether divides both products or only the second. The characteristic 8.7.4.1 refers to is the one of IEC 60268-3:2013, 14.12.8.1 b): “the ratio of the arithmetic sum of the output voltages at frequencies and to the reference voltage which is equal to twice the output voltage ”, that is .
- Evidence: Formula (5) on PDF page 31 (printed p. 29) of IEC 60268-7:2010, Edition 3.0, read against 14.12.8.1 b) on PDF page 38 (printed p. 36) of IEC 60268-3:2013.
- Library behaviour:
difference_frequency_distortiondivides the arithmetic sum of both third-order products by the sum of the two tones’ amplitudes, which is for the equal tones ofheadphone_difference_frequency_signal. No change was required. - Status: unreported.
IEC 60268-7:2010, 8.7.4.2 a) (the test signal sent to 8.7.3.1)
Section titled “IEC 60268-7:2010, 8.7.4.2 a) (the test signal sent to 8.7.3.1)”- Location: 8.7.4.2 a), printed p. 28.
- The print: “The headphone is brought under standard measuring conditions, and then the input signal is changed to that required for the measurement (see 8.7.3.1).”
- The problem: 8.7.3.1 is the general subclause of modulation distortion, one sentence that refers to IEC 60268-2. The signal the difference-frequency measurement requires, two sinusoids 80 Hz apart, each giving half the rated input voltage, is specified in 8.7.4.1, a few lines above the item.
- Evidence: 8.7.3.1, 8.7.4.1 and 8.7.4.2 a) on PDF page 30 (printed p. 28) of IEC 60268-7:2010, Edition 3.0.
- Library behaviour: none needed.
headphone_difference_frequency_signalgenerates the signal of 8.7.4.1. - Status: unreported (cross-reference defect, no numerical consequence).
IEC 60268-7:2010, Figure 3, NOTE (the head and torso simulator cited as IEC 60969)
Section titled “IEC 60268-7:2010, Figure 3, NOTE (the head and torso simulator cited as IEC 60969)”- Location: the NOTE under Figure 3, “Illustrated measurement diagram by simulated programme signal”, printed p. 16.
- The print: “Power summation of the 1/3-octave-analized data multiplied by filtering coefficients given by IEC 61672-1 and/or IEC 60969 gives the corrected voltage.”
- The problem: the filtering coefficients the NOTE means are those of the two filters 7.4 lists above the figure, the A-weighting of IEC 61672-1 and the “free field compensating filter, that is the filter with inverse response of the free field response of the manikin specified in IEC 60959”. The figure itself labels the manikin “HATS (IEC 60959)”, and Clause 2 lists IEC TR 60959 among the normative references; it lists no IEC 60969. The digits are transposed.
- Evidence: 7.4 and Figure 3 on PDF pages 17 and 18 (printed pp. 15 and 16), and Clause 2 on PDF page 9 (printed p. 7), of IEC 60268-7:2010, Edition 3.0.
- Library behaviour: none needed.
program_signal_leveltakes the free-field response of the head and torso simulator as an input and compensates it. - Status: unreported (cross-reference defect, no numerical consequence).
IEC 60268-7:2010, 8.6.3 to 8.6.5 (cross-references that miss their subclause)
Section titled “IEC 60268-7:2010, 8.6.3 to 8.6.5 (cross-references that miss their subclause)”- Location: 8.6.3.2 a) and b), 8.6.3.3, 8.6.4.2 a) and b), 8.6.4.3, 8.6.5.2 a) and b) and 8.6.5.3, printed pp. 24 to 27.
- The print: the free-field and diffuse-field comparison measurements bring the headphone under comparison conditions “(see 7.4 and Annex C)” and “(see 7.4 and Annex D)”, and cover “at least the rated frequency range (see 8.6.5)”; 8.6.3.3 uses a headphone “measured as described in 8.6.2.2” and 8.6.4.3 one “measured as described in 8.6.3.2”, with its results “calculated as described in 8.6.3.2”; 8.6.5.2 a) refers to “8.6.2.2 or 8.6.3.2 and Annex E” for the conditions, b) to 8.6.5 for the rated frequency range and reads the probe microphone “through a 1/3 octave filter with appropriate centre frequency (see 7.5 and Annex B)”; 8.6.5.3 is “the same as given in 8.6.4.2, except that the sound field is replaced by a headphone, previously calibrated by the method of 8.6.4.2, using at least 16 test persons”.
- The problem: 7.4 is the measurement conditions for the simulated programme signal; the free-field and diffuse-field comparison conditions are 7.5.2 and 7.5.3, and the ear canal measurement conditions, with “A very small microphone, in accordance with the requirements in Annex B”, are 7.6, not 7.5, the loudness comparison conditions. The rated frequency range is 8.6.6, which 8.6.2.2 b) cites correctly. The direct measurement a substitution reference has to come from, and the one whose results it calculates like, is 8.6.3.2 for the free field and 8.6.4.2 for the diffuse field; the conditions 8.6.5.2 a) borrows are those of the same two methods, 8.6.3.2 and 8.6.4.2; and the direct ear-canal method 8.6.5.3 repeats is 8.6.5.2. Each reference lands one subclause short of the one its text describes. The second 8.6.4.2 of 8.6.5.3 follows the same pattern: the headphone that replaces the sound field of an ear canal measurement has to be calibrated by the ear canal method, 8.6.5.2, since 8.6.4.2 is a loudness comparison against the diffuse field alone and cannot calibrate the free-field ear canal response that 8.6.5.1 a) also covers.
- Evidence: the references read against the subclauses they name, on PDF pages 26 to 29 (printed pp. 24 to 27), with 7.4 to 7.6 on PDF pages 17 to 19 (printed pp. 15 to 17), of IEC 60268-7:2010, Edition 3.0.
- Library behaviour:
field_comparison_responseandear_canal_frequency_responsefollow the text of each method; the 16-person panel of a substitution reference is the one of 8.6.3.3 and 8.6.4.3 (FieldComparisonResponse.qualifies_as_reference), and the one of 8.6.5.3 is read as a panel of the direct ear canal method (EarCanalFrequencyResponse.qualifies_as_reference). The conformance row “IEC 60268-7:2010 8.6.5.3 with 8.6.5.2 h)” pins the 8 and 16 persons. - Status: unreported (cross-reference defect).
IEC 60268-7:2010, Table 1 (six clause numbers that name another subclause)
Section titled “IEC 60268-7:2010, Table 1 (six clause numbers that name another subclause)”- Location: Table 1, “Classification of characteristics”, printed p. 32.
- The print: the rows “8.3.4 Rated characteristics of protective devices”, “8.5.1 Rated maximum or working sound pressure level”, “8.6.5 Rated frequency range”, “8.7.1 Rated harmonic distortion”, “8.7.2 Rated modulation distortion” and “8.7.3 Rated difference-frequency distortion”.
- The problem: in this edition the protective devices are 8.3.6 (8.3.4 is the simulated programme signal characteristic voltage), the maximum and working sound pressure levels are specified in 8.5.2 (8.5.1 is the general subclause), the rated frequency range is 8.6.6, and the harmonic, modulation and difference-frequency distortions are 8.7.2, 8.7.3 and 8.7.4 (8.7.1 is the general subclause).
- Evidence: Table 1 on PDF page 34 (printed p. 32) read against the contents list on PDF pages 4 and 5 (printed pp. 2 and 3) of IEC 60268-7:2010, Edition 3.0.
- Library behaviour: none needed; the library does not read Table 1.
- Status: unreported (cross-reference defect, no numerical consequence).
IEC 60268-7:2010, 8.3.4.2 NOTE 1 (a crest factor credited to IEC 60268-1)
Section titled “IEC 60268-7:2010, 8.3.4.2 NOTE 1 (a crest factor credited to IEC 60268-1)”- Location: 8.3.4.2, NOTE 1, printed p. 20.
- The print: “IEC 60268-1 specifies the spectrum, filtering circuit and crest factor of the simulated programme signal.”
- The problem: IEC 60268-1:1985, which Clause 2 cites undated, specifies the spectrum (Table II, Figure 1) and the filtering circuit (Figure 2) and no crest factor: Clause 7 defines the signal as “stationary weighted Gaussian noise without amplitude limiting”. Neither amendment of 1988 adds one; Amendment 1 replaces Table AII and Amendment 2 replaces 12.1. The only crest factor the two parts print is the “peak-to-r.m.s ratio between 1,8 and 2,2” of IEC 60268-7 8.3.2.2 b) itself, for the clipped signal of the limiting voltages.
- Evidence: NOTE 1 on PDF page 22 (printed p. 20) and 8.3.2.2 b) on PDF page 21 (printed p. 19) of IEC 60268-7:2010, Edition 3.0; Clause 7 on PDF page 15 (printed p. 13), Table II on PDF page 23 (printed p. 21) and Figures 1 and 2 on PDF page 24 (printed p. 22) of IEC 60268-1:1985.
- Library behaviour: none needed.
simulated_program_signalis unclipped by default, as Clause 7 asks, and clips to a peak-to-RMS ratio only whenpeak_to_rmsis given, which the library credits to 8.3.2.2 b). - Status: unreported (cross-reference defect, no numerical consequence).
IEC 60268-7:2010, 8.5.2 b) and 8.5.3 c) (two settings of the e.m.f. of 1 mW)
Section titled “IEC 60268-7:2010, 8.5.2 b) and 8.5.3 c) (two settings of the e.m.f. of 1 mW)”- Location: 8.5.2 b), printed p. 22; 8.5.3 c) and d), printed p. 23.
- The print: 8.5.2 b) defines the working sound pressure level at “a sinusoidal voltage at 500 Hz, in series with the rated source impedance, of such value that 1 mW would be dissipated in a pure resistance equal to the rated impedance of the headphone, connected in place of it”. The method, 8.5.3 c): “The source e.m.f. is then adjusted so that the voltage across the input connector of the headphone is such that it would cause 1 mW to be dissipated in a pure resistance equal to the rated impedance of the headphone”, and d) states the level “as the result b) in 8.5.2”.
- The problem: the two set different e.m.f.s. With a rated impedance , a rated source impedance and 1 mW, the definition asks for , the e.m.f. that drives 1 mW into in place of the headphone; the method asks for the e.m.f. that puts across the headphone itself, whose impedance at 500 Hz takes its own share, . They agree only when is the rated impedance or is zero. A 32 Ω headphone of 40 Ω at 500 Hz on the 120 Ω source of IEC 61938 reads dB lower by the method than by the definition, and the rated impedance of 8.2.1 b) allows the modulus to sit anywhere above 80 % of .
- Evidence: 8.5.2 b) on PDF page 24 (printed p. 22) and 8.5.3 c) and d) on PDF page 25 (printed p. 23) of IEC 60268-7:2010, Edition 3.0.
- Library behaviour:
working_sound_pressure_levelfollows the definition of 8.5.2 b) to d) by default, and the method of 8.5.3 c) when it is given the headphone’s measured impedance at 500 Hz asheadphone_impedance_ohm; the conformance row “IEC 60268-7:2010 8.5.2 b) and 8.5.3 c)” pins the 1.49 dB. - Status: unreported.
Created and maintained by José Manuel Requena PlensORCIDAbout the maintainerRelease notesChangelogAll projects