Skip to content

vibration.machinery.evaluation

Evaluation of machine vibration by measurement (ISO 20816-1:2016).

Condition monitoring answers two questions, and they are not the same one. diagnostics answers where a fault would show, by turning the geometry of a bearing or a gear pair into the frequencies it excites. This module answers the prior question a plant actually asks: is this machine acceptable at all, from one broad-band magnitude measured at a bearing.

ISO 20816-1 is the basis document of the series, merging what used to be ISO 10816-1 and ISO 7919-1. It fixes the shape of the answer and leaves the numbers to the machine-specific parts.

Four evaluation zones (6.3.2.3) grade a machine rather than pass or fail it. Zone A is where newly commissioned machines normally fall; zone B is acceptable for unrestricted long-term operation; zone C is unsatisfactory for long-term continuous running, though the machine may run a limited period until remedial action can be arranged; zone D is severe enough to cause damage. Three boundaries separate them, and evaluation_zone is the comparison itself, blind to the quantity: the specific parts set boundaries on shaft displacement, housing velocity or housing acceleration, and the grading is the same in all three.

Criterion I (6.3.2) is that comparison applied to the vibration severity, the largest broad-band magnitude measured at any bearing at rated speed. Velocity carries it over a wide speed range, but a single velocity limit regardless of frequency allows unacceptable displacement at low frequency and unacceptable acceleration at high frequency. So the criterion is a curve, flat between two corner frequencies and sloped outside them (Figure 9, Formula (C.1)):

with below the lower corner and above it, and above the upper corner and below it, so both bracketed factors are unity between the corners. moves the one curve onto the three boundaries, and Annex C.2 prints the factors it takes: 1 for the limit of zone A, 2.56 for zone B and 6.4 for zone C.

Criterion II (6.3.3) judges a change from an established baseline, and a change is a vector. Annex D makes the point with a machine whose magnitude fell from 3 mm/s to 2.5 mm/s while its phase swung from 40° to 180°: the magnitude moved by half a millimetre per second, and the vibration itself moved by 5.2 mm/s, ten times as much. vibration_vector_change is that subtraction.

Where no part of the series covers a machine and no experience is available, Annex C.1 offers Table C.1: a ladder of preferred magnitudes and the range each boundary is typically drawn from, with small machines at the low end and large flexibly supported ones at the high end. They are a starting point for agreement between supplier and customer, not an acceptance specification.

Auto-generated from the source docstrings by scripts/generate_api_docs.py (make api-docs). Do not edit by hand.

alarm_limit(baseline: float, zone_b_upper: float) -> float

The ALARM setting a baseline and a zone B/C boundary imply (5.4.1).

The recommendation is two rules at once: set the ALARM a quarter of the upper limit of zone B above the established baseline, and do not normally let it exceed 1.25 times that limit. A machine with a low baseline therefore alarms below zone C, which the clause says in as many words, and one with a high baseline is capped rather than allowed to drift up with it.

Parameters

Name Description
baseline The steady-state baseline for that measurement position and direction, in the unit the boundaries are in.
zone_b_upper The upper limit of zone B, which is the B/C boundary.

Returns: The ALARM setting.

Raises

Exception When
ValueError If the baseline is negative or the limit is not positive.
TypeError if baseline or zone_b_upper is not a single number.
allowable_velocity(
frequency: float | np.floating[Any] | np.integer[Any],
*,
constant_velocity_mm_s: float,
zone_factor: float = 1.0,
corner_low_hz: float,
corner_high_hz: float,
exponent_low: float = 1.0,
exponent_high: float = 1.0,
) -> float
allowable_velocity(
frequency: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
*,
constant_velocity_mm_s: float,
zone_factor: float = 1.0,
corner_low_hz: float,
corner_high_hz: float,
exponent_low: float = 1.0,
exponent_high: float = 1.0,
) -> NDArray[np.float64]
allowable_velocity(
frequency: NumericArrayLike,
*,
constant_velocity_mm_s: float,
zone_factor: float = 1.0,
corner_low_hz: float,
corner_high_hz: float,
exponent_low: float = 1.0,
exponent_high: float = 1.0,
) -> float | NDArray[np.float64]

Frequency-shaped velocity criterion of Figure 9 (Formula (C.1)).

Flat between the two corner frequencies and sloped outside them. The default exponents of 1 are the physical reading of that shape: below the lower corner the criterion holds displacement constant, so the allowable velocity rises with frequency at 6 dB per octave, and above the upper corner it holds acceleration constant, so it falls at the same rate. The curve is therefore lowest where the machine is slowest and where it is fastest, and flat in between. A machine-specific part that states its own k and m overrides them.

Parameters

Name Description
frequency Frequency f, in hertz (scalar or array).
constant_velocity_mm_s The constant r.m.s. velocity vA that applies between the corners for zone A, in millimetres per second.
zone_factor Zbound, the factor that moves the curve onto a zone limit; see ZONE_LIMIT_FACTORS for the 1 / 2.56 / 6.4 of Annex C.2.
corner_low_hz The lower corner fx, in hertz.
corner_high_hz The upper corner fy, in hertz; must exceed corner_low_hz.
exponent_low k, the slope below the lower corner.
exponent_high m, the slope above the upper corner.

Returns: The allowable r.m.s. velocity, in millimetres per second; a float for a number; an array for a sequence or an array, a zero-dimensional one included.

Raises

Exception When
ValueError If a frequency is not positive, a velocity or corner is not positive and finite, or the corners are not in order.
TypeError if constant_velocity_mm_s, corner_high_hz, corner_low_hz or zone_factor is not a single number, or frequency holds a text or a value that is not a real number.
assess_operational_change(
change: float,
zone_b_upper: float,
) -> OperationalChange

Is a change from the baseline significant? (5.3).

A change exceeding a quarter of the upper limit of zone B, in either direction, is one that 5.3 asks to be investigated even when zone C of Criterion I has not been reached: the machine can go wrong well inside zone B, and the criterion that catches it is the change rather than the magnitude.

Parameters

Name Description
change The change from the established baseline, in the unit the boundaries are in; the sign is ignored.
zone_b_upper The upper limit of zone B, which is the B/C boundary.

Returns: The answer, as an OperationalChange.

Raises

Exception When
ValueError If the change is not finite or the limit is not positive.
TypeError if change or zone_b_upper is not a single number.
evaluation_zone(
magnitude: float | np.floating[Any] | np.integer[Any],
boundaries: ZoneBoundaries,
) -> Literal['A', 'B', 'C', 'D']
evaluation_zone(
magnitude: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
boundaries: ZoneBoundaries,
) -> NDArray[np.str_]
evaluation_zone(
magnitude: NumericArrayLike,
boundaries: ZoneBoundaries,
) -> Literal['A', 'B', 'C', 'D'] | NDArray[np.str_]

Grade a vibration magnitude into zone A, B, C or D (6.3.2.3).

The boundaries belong to a zone each: a magnitude exactly on the A/B boundary is the limit of zone A and is graded "A", which is how a limit reads in the tables of the machine-specific parts.

Parameters

Name Description
magnitude The vibration severity, in the same quantity and unit as boundaries (scalar or array).
boundaries The three zone boundaries of the applicable part of ISO 20816.

Returns: "A", "B", "C" or "D": a string for a number; an array of them for a sequence or an array, a zero-dimensional one included.

Raises

Exception When
ValueError If a magnitude is negative or not finite.
TypeError if magnitude holds a text or a value that is not a real number.

Constant (float).

GEAR_ACCEPTANCE_HEADROOM = 1.25

Constant (float).

GEAR_DISPLACEMENT_CORNER_HZ = 50.0

Constant (float).

GEAR_DISPLACEMENT_SLOPE_DB_PER_DECADE = 10.0
gear_housing_velocity_limit(
frequency: float | np.floating[Any] | np.integer[Any],
*,
rating: float,
) -> float
gear_housing_velocity_limit(
frequency: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
*,
rating: float,
) -> NDArray[np.float64]
gear_housing_velocity_limit(
frequency: NumericArrayLike,
*,
rating: float,
) -> float | NDArray[np.float64]

The housing velocity rating curve of Figure A.2.

Flat between 45 Hz and 1590 Hz and falling outside both corners at 14 dB per decade, which is the shape allowable_velocity already draws for ISO 20816-1 Formula (C.1); this is that formula with the corners and the exponents Part 9 states, so the two parts of the series share one curve rather than two implementations of it.

Parameters

Name Description
frequency Frequency f, in hertz (scalar or array).
rating The velocity rating VR, in millimetres per second.

Returns: The allowable r.m.s. velocity, in millimetres per second; a float for a number; an array for a sequence or an array, a zero-dimensional one included.

Raises

Exception When
ValueError If a frequency or the rating is not positive.
TypeError if rating is not a single number.
gear_shaft_displacement_limit(
frequency: float | np.floating[Any] | np.integer[Any],
*,
rating: float,
) -> float
gear_shaft_displacement_limit(
frequency: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
*,
rating: float,
) -> NDArray[np.float64]
gear_shaft_displacement_limit(
frequency: NumericArrayLike,
*,
rating: float,
) -> float | NDArray[np.float64]

The shaft displacement rating curve of Figure A.1.

The note under the figure states both halves: the rating number is the displacement of the curve up to 50 Hz, and above 50 Hz the curves decrease by 10 dB per decade, which on an amplitude is an exponent of one half.

Parameters

Name Description
frequency Frequency f, in hertz (scalar or array).
rating The displacement rating DR, in micrometres.

Returns: The allowable peak-to-peak displacement, in micrometres; a float for a number; an array for a sequence or an array, a zero-dimensional one included.

Raises

Exception When
ValueError If a frequency or the rating is not positive.
TypeError if rating is not a single number, or frequency holds a text or a value that is not a real number.

Constant (mapping).

GEAR_UNIT_CLASSES = {('I', 'a'): GearUnitRatings(displacement=31.5, velocity=3.15, acceleration=50.0), ('I', 'b_low'): GearUnitRatings(displacement=31.5, velocity=3.15, acceleration=None), ('I', 'b_high'): GearUnitRatings(displacement=50.0, velocity=5.0, acceleration=None), ('II', 'a'): GearUnitRatings(displacement=50.0, velocity=5.0, acceleration=80.0), ('II', 'b_low'): GearUnitRatings(displacement=50.0, velocity=5.0, acceleration=None), ('II', 'b_high'): GearUnitRatings(displacement=80.0, velocity=8.0, acceleration=None), ('III', 'a'): GearUnitRatings(displacement=80.0, velocity=8.0, acceleration=125.0), ('III', 'b_low'): GearUnitRatings(displacement=80.0, velocity=8.0, acceleration=None), ('III', 'b_high'): GearUnitRatings(displacement=125.0, velocity=12.5, acceleration=None), ('IV', 'a'): GearUnitRatings(displacement=125.0, velocity=20.0, acceleration=125.0), ('IV', 'b_low'): GearUnitRatings(displacement=125.0, velocity=12.5, acceleration=None), ('IV', 'b_high'): GearUnitRatings(displacement=200.0, velocity=20.0, acceleration=None)}
gear_unit_zone_boundaries(
quantity: Literal['displacement', 'velocity', 'acceleration'],
rating: float,
) -> ZoneBoundaries

The three boundaries Table 2, 3 or 4 prints for one rating.

The tables are printed for the rating numbers they list and for no others, so a rating between two rows is refused rather than interpolated: the ladder is a choice made with the manufacturer, not a continuum. The comparison is a relative one to a part in a thousand million, so a rating that arrived through a computation and carries floating-point noise still finds its row; nothing a reader would call a different rating does.

Parameters

Name Description
quantity "displacement" (Table 2, shaft relative peak-to-peak, µm), "velocity" (Table 3, housing r.m.s., mm/s) or "acceleration" (Table 4, housing true peak, m/s²).
rating The rating number, DR, VR or AR.

Returns: The A/B, B/C and C/D boundaries of that row.

Raises

Exception When
ValueError If the quantity is unknown or the table prints no row for that rating.
TypeError if quantity is not a text, or rating is not a single number.

Constant (mapping).

GEAR_UNIT_ZONES = {'displacement': {31.5: ZoneBoundaries(a_b=20.0, b_c=31.5, c_d=50.0), 50.0: ZoneBoundaries(a_b=31.5, b_c=50.0, c_d=80.0), 80.0: ZoneBoundaries(a_b=50.0, b_c=80.0, c_d=125.0), 125.0: ZoneBoundaries(a_b=80.0, b_c=125.0, c_d=200.0), 200.0: ZoneBoundaries(a_b=125.0, b_c=200.0, c_d=315.0)}, 'velocity': {3.15: ZoneBoundaries(a_b=2.0, b_c=3.15, c_d=5.0), 5.0: ZoneBoundaries(a_b=3.15, b_c=5.0, c_d=8.0), 8.0: ZoneBoundaries(a_b=5.0, b_c=8.0, c_d=12.5), 12.5: ZoneBoundaries(a_b=8.0, b_c=12.5, c_d=20.0), 20.0: ZoneBoundaries(a_b=12.5, b_c=20.0, c_d=31.5)}, 'acceleration': {5.0: ZoneBoundaries(a_b=3.15, b_c=5.0, c_d=8.0), 8.0: ZoneBoundaries(a_b=5.0, b_c=8.0, c_d=12.5), 12.5: ZoneBoundaries(a_b=8.0, b_c=12.5, c_d=20.0), 20.0: ZoneBoundaries(a_b=12.5, b_c=20.0, c_d=31.5), 31.5: ZoneBoundaries(a_b=20.0, b_c=31.5, c_d=50.0), 50.0: ZoneBoundaries(a_b=31.5, b_c=50.0, c_d=80.0), 80.0: ZoneBoundaries(a_b=50.0, b_c=80.0, c_d=125.0), 125.0: ZoneBoundaries(a_b=80.0, b_c=125.0, c_d=200.0), 200.0: ZoneBoundaries(a_b=125.0, b_c=200.0, c_d=315.0)}}

Constant (tuple).

GEAR_VELOCITY_CORNERS_HZ = (45.0, 1590.0)

Constant (float).

GEAR_VELOCITY_SLOPE_DB_PER_DECADE = 14.0
GearUnitRatings(
displacement: float,
velocity: float,
acceleration: float | None,
)

The three rating numbers Table 5 gives one class of gear unit.

Attributes

Name Description
displacement The displacement rating DR, which indexes Table 2.
velocity The velocity rating VR, which indexes Table 3.
acceleration The acceleration rating AR, which indexes Table 4, or None where the table prints “no information available at this time”, which it does for every subclass b) row.
industrial_machine_zone(
group: Literal['group_1', 'group_2'],
support: Literal['rigid', 'flexible'],
*,
displacement_um: float | np.floating[Any] | np.integer[Any] | None = None,
velocity_mm_s: float | np.floating[Any] | np.integer[Any] | None = None,
) -> Literal['A', 'B', 'C', 'D']
industrial_machine_zone(
group: Literal['group_1', 'group_2'],
support: Literal['rigid', 'flexible'],
*,
displacement_um: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
velocity_mm_s: NumericArrayLike | None = None,
) -> NDArray[np.str_]
industrial_machine_zone(
group: Literal['group_1', 'group_2'],
support: Literal['rigid', 'flexible'],
*,
displacement_um: float | np.floating[Any] | np.integer[Any] | None = None,
velocity_mm_s: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
) -> NDArray[np.str_]
industrial_machine_zone(
group: Literal['group_1', 'group_2'],
support: Literal['rigid', 'flexible'],
*,
displacement_um: NumericArrayLike | None = None,
velocity_mm_s: NumericArrayLike | None = None,
) -> Literal['A', 'B', 'C', 'D'] | NDArray[np.str_]

Grade an industrial machine against Table A.1 or A.2.

Give whichever quantities were measured. With both, 5.2.3 applies and the result is the more restrictive of the two gradings, which is the whole reason the tables state each class twice.

Parameters

Name Description
group "group_1" (above 300 kW, or an electrical machine of shaft height 315 mm or more) or "group_2" (above 15 kW up to and including 300 kW, or shaft height from 160 mm up to but not including 315 mm), from 4.2. Table A.1 caps group 1 at 50 MW in its title.
support "rigid" or "flexible"; rigid means the lowest natural frequency of the support in the measuring direction is at least 25 % above the main excitation frequency (4.3).
displacement_um Measured broad-band r.m.s. displacement of the bearing, pedestal or housing, in micrometres (scalar or array).
velocity_mm_s Measured broad-band r.m.s. velocity, in millimetres per second (scalar or array).

Returns: "A", "B", "C" or "D": a string when every measurement given is a number; an array of them, broadcast over the two, when one is a sequence or an array, a zero-dimensional one included.

Raises

Exception When
ValueError If the group or support class is unknown, or neither measured quantity is given.
TypeError if group or support is not a text.

Constant (mapping).

INDUSTRIAL_MACHINE_ZONES = {('group_1', 'rigid'): MachineZoneLimits(displacement_um=ZoneBoundaries(a_b=29.0, b_c=57.0, c_d=90.0), velocity_mm_s=ZoneBoundaries(a_b=2.3, b_c=4.5, c_d=7.1)), ('group_1', 'flexible'): MachineZoneLimits(displacement_um=ZoneBoundaries(a_b=45.0, b_c=90.0, c_d=140.0), velocity_mm_s=ZoneBoundaries(a_b=3.5, b_c=7.1, c_d=11.0)), ('group_2', 'rigid'): MachineZoneLimits(displacement_um=ZoneBoundaries(a_b=22.0, b_c=45.0, c_d=71.0), velocity_mm_s=ZoneBoundaries(a_b=1.4, b_c=2.8, c_d=4.5)), ('group_2', 'flexible'): MachineZoneLimits(displacement_um=ZoneBoundaries(a_b=37.0, b_c=71.0, c_d=113.0), velocity_mm_s=ZoneBoundaries(a_b=2.3, b_c=4.5, c_d=7.1))}
MachineZoneLimits(
displacement_um: ZoneBoundaries,
velocity_mm_s: ZoneBoundaries,
)

The two boundary sets one machine class is judged on at once.

ISO 10816-3:2009 states each class twice, once in displacement and once in velocity, and 5.2.3 says which wins when they disagree: the more restrictive zone applies. Both are read on the same non-rotating part, and Annex A says velocity alone is enough in most cases and that a spectrum expected to carry low-frequency components should be judged on both.

Attributes

Name Description
displacement_um The three boundaries in r.m.s. displacement, micrometres.
velocity_mm_s The three boundaries in r.m.s. velocity, millimetres per second.

Constant (float).

OPERATIONAL_LIMIT_HEADROOM = 1.25
OperationalChange(change: float, zone_b_upper: float)

A change from the baseline against what 5.3 calls significant.

The threshold and the answer are read from the change and the boundary, so they are not fields: a record cannot be built to call a change significant that the clause does not.

Attributes

Name Description
change The change from the established baseline, in the unit the boundaries are in; signed, and judged by its size.
zone_b_upper The upper limit of zone B, which is the B/C boundary.

property

Whether the change, in either direction, exceeds threshold.

A significant change is a reason to investigate, not a failure: the machine may still be inside zone B.

property

A quarter of the upper limit of zone B, the size 5.3 asks to investigate.

Constant (float).

SIGNIFICANT_CHANGE_FRACTION = 0.25
trip_limit(zone_c_upper: float) -> float

The largest TRIP setting 5.4.2 recommends.

Unlike an ALARM, a TRIP is not set from a baseline: it relates to the mechanical integrity of the machine and is the same for every machine of a design. The clause declines to give absolute values and gives a ceiling instead, 1.25 times the upper limit of zone C.

Parameters

Name Description
zone_c_upper The upper limit of zone C, which is the C/D boundary.

Returns: The recommended maximum TRIP setting.

Raises

Exception When
ValueError If the limit is not positive.
TypeError if zone_c_upper is not a single number.

Constant (tuple).

TYPICAL_BOUNDARY_LADDER_MM_S = (0.28, 0.45, 0.71, 1.12, 1.8, 2.8, 4.5, 7.1, 9.3, 11.2, 14.7, 18.0, 28.0, 45.0)

Constant (mapping).

TYPICAL_ZONE_BOUNDARY_RANGES_MM_S = {'A/B': (0.71, 4.5), 'B/C': (1.8, 9.3), 'C/D': (4.5, 14.7)}
VectorChangeResult(
magnitude: float,
phase_deg: float,
initial: tuple[float, float],
final: tuple[float, float],
)

A change in vibration between two states, as a vector (Annex D).

Attributes

Name Description
magnitude The magnitude of the change, in the unit of the two states it was built from.
phase_deg The direction of the change, in degrees within [0, 360).
initial The magnitude and phase of the initial state.
final The magnitude and phase of the final state.

property

What a magnitude-only comparison would have reported.

The difference of the two magnitudes, signed. Annex D exists because this number and magnitude can disagree by an order of magnitude, and only the second is the change in the vibration.

VectorChangeResult.plot(
ax: PolarAxes | None = None,
*,
language: Literal['en', 'es'] = 'en',
**kwargs: Any,
) -> PolarAxes

Draw the polar diagram of Figure D.1.

The two states as vectors from the origin and the change as the vector joining their tips, which is the picture that makes the point.

Requires matplotlib (the [plot] extra); returns the polar axes it drew on.

Parameters

Name Description
ax Existing polar axes, or None to create a figure.
language Label language, "en" (default) or "es".
kwargs unit, the name of the unit the two states were given in, and anything forwarded to the change chord; see phonometry._plot.vibration.plot_vector_change.

Returns: The polar axes.

Raises

Exception When
ValueError If ax is not a polar axes.
vibration_vector_change(
initial_magnitude: float,
initial_phase_deg: float,
final_magnitude: float,
final_phase_deg: float,
) -> VectorChangeResult

The vector change in vibration between two steady states (Annex D).

Criterion II is written on a change from an established baseline, and a broad-band magnitude cannot express one: a component that swings in phase changes the vibration even as the magnitude it contributes falls. Annex D prints the case, 3 mm/s at 40 degrees becoming 2.5 mm/s at 180 degrees, where the magnitude drops by half a millimetre per second and the vibration moves by 5.2.

Parameters

Name Description
initial_magnitude Magnitude of the reference state, in any unit; the result carries the same one.
initial_phase_deg Phase of the reference state, in degrees.
final_magnitude Magnitude of the later state, in the same unit.
final_phase_deg Phase of the later state, in degrees.

Returns: The VectorChangeResult.

Raises

Exception When
ValueError If a magnitude is negative or a value is not finite.
TypeError if final_magnitude, final_phase_deg, initial_magnitude or initial_phase_deg is not a single number.

Constant (mapping).

ZONE_LIMIT_FACTORS = {'A': 1.0, 'B': 2.56, 'C': 6.4}
ZoneBoundaries(*, a_b: float, b_c: float, c_d: float)

The three magnitudes that separate the four evaluation zones.

The unit is whichever the machine-specific part states: micrometres of shaft displacement, millimetres per second of housing velocity or metres per second squared of housing acceleration. Nothing here converts between them, and the boundaries and the magnitude judged against them have to be the same quantity.

Attributes

Name Description
a_b The zone A/B boundary, below which a newly commissioned machine normally sits.
b_c The zone B/C boundary, the limit of unrestricted long-term operation.
c_d The zone C/D boundary, above which the vibration is severe enough to damage the machine.

property