# What a seat does to the vibration

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/vibration/human/seat-vibration/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/vibration/human/seat-vibration/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-08
Updated: 2026-11-16T21:36:14Z
Standards: ISO 10326-1:2016
Verified: 7 conformance checks (ISO 10326-1:2016) https://docs.jmrp.io/phonometry/reference/conformance/#seat-vibration-transmission-iso-10326-1
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: ISO 10326-1 laboratory seat test: SEAT factor, three runs within 5 %, input correction and transmissibility at resonance.

---

A driver does not sit on the floor of the machine. The seat is in between, and
whether it helps is not obvious: a suspension seat is a spring and a damper,
and a spring has a resonance. Feed it the wrong spectrum and it amplifies
exactly what it was bought to attenuate.

[Human vibration exposure](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/)
measures what reaches the person. This page is the laboratory method that
measures what the seat did to it, and it answers with one number.

## 1. The SEAT factor

Mount the seat on a vibration simulator, drive the platform with the input
spectrum the application standard prescribes, sit a test person in it, and
measure the frequency-weighted r.m.s. acceleration in two places. The ratio is
the seat effective amplitude transmissibility, which everybody calls the SEAT
factor (10.2.2):

$$
\mathrm{SEAT} = \frac{a_\mathrm{wS}}{a_\mathrm{wP}}
$$

Below 1 the seat is doing its job. At 1 the two measurements are equal, so
the seat passed the vibration through unchanged, which is what a rigid plank
would do and also what a seat does when its attenuation over part of the
spectrum is cancelled by amplification over the rest. Above 1 it is making the
ride worse than no seat at all, which is not a hypothetical: it is
what a suspension does when the machine's dominant frequency lands on its
resonance.

$a_\mathrm{wS}$ is the arithmetic mean of **three consecutive runs whose seat
values lie within ± 5 % of that mean**, and $a_\mathrm{wP}$ the mean of the
platform values from those same runs, which have to stay inside the input
tolerances rather than inside the 5 % (10.2.1). The library treats the
agreement as a condition rather than a footnote: `mean_of_test_runs` refuses a
set that does not meet the spread, because a mean of runs that disagree by more
is not a measurement this standard recognises. `seat_transmission` puts both
sets through it, so on the platform side it is stricter than the clause.

![Two panels. The left panel gives three test runs as paired bars, the platform near 1.00 and the seat near 0.71 metres per second squared, with the mean of each set drawn as a dashed line and a double arrow between the two means labelled SEAT = 0.71. The right panel gives four bars for the correction of clause 10.2.3: the input delivered at 1.00, the input intended at 1.10, the magnitude measured on the seat at 0.71 and the corrected magnitude at 0.78, over the formula a\*wS = SEAT times a\*wP.](https://docs.jmrp.io/phonometry/media/seat_vibration_test.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import vibration

# Three runs at the platform and three at the seat, in m/s2.
test = vibration.seat_transmission(
    [0.72, 0.70, 0.71], [1.02, 1.00, 0.99]
)
print(round(test.seat_factor, 3), test.attenuates)     # 0.708 True
test.plot()
plt.show()

# Runs that do not agree within 5 % are not a measurement:
try:
    vibration.mean_of_test_runs([1.0, 1.2, 1.0])
except ValueError as error:
    print(error)
# The runs differ from their mean by 12.5 %, more than the 5 % this test allows.
```

*One test, and the ratio it exists to produce. The three runs agree to well
inside the tolerance, so their means are the two numbers the SEAT factor is
built from.*

### How the measurement goes

![Laboratory arrangement for testing a vehicle seat. On the left, from the side: a suspension seat with a spring and a damper on the platform of a vibration simulator that drives it vertically from below, its backrest leaning back ten degrees plus or minus five, and a test person sitting on it with the feet on a separate support and the thighs clear of the front of the cushion. The mounting disc lies on the cushion under the person's pelvis and carries the seat accelerometer S; a dash-dot line drops from S to the platform, where the platform accelerometer P stands no more than 100 millimetres from it. On the right, the disc in section, 250 plus or minus 50 millimetres across and no more than 12 millimetres high, with the accelerometers in a central cavity on a metal disc of 75 plus or minus 5 millimetres and 1.5 plus or minus 0.2 millimetres thick, a rim of 3 plus or minus 1 millimetres, in rubber or plastics of 80 to 90 durometer. Below it, P and S go through the same weighted r.m.s. chain to ISO 8041: a_wP is the mean of the runs with the input within tolerance, and a_wS the mean of three runs, each within 5 percent of it. Four notes give the platform circle, the disc position with its 15 degree axis tolerance, the 75 kilogram run-in and the warm-up, and the two test persons with the feet support. A box at the foot carries SEAT equals a_wS over a_wP, and the corrected magnitude a\*\_wS equals SEAT times a\*\_wP](https://docs.jmrp.io/phonometry/media/diagram_seat_test_rig.svg)

Use a measuring chain that meets ISO 8041, alike at the platform and at the
seat, and calibrate it to ISO 16063-1 before and after each test series. Mount
the seat, check the safety requirements of ISO 13090-1, and, if the seat has a
suspension, run it in: a 75 kg inert mass on the cushion, the seat adjusted for
a 100 kg operator, and a sine near the natural frequency of the suspension at
75 % of its full amplitude, until the seat settles. Set the ride height as 8.1.3
describes and an adjustable backrest to about 10° back. Fix the platform
accelerometer inside a 200 mm circle centred directly below the seat
accelerometer, and tape the disc to the cushion so its accelerometers lie
midway between the ischial tuberosities. Train the test persons in preliminary
runs until they hold a normal, still posture throughout. Weigh each of them
just before their series, set the feet support so the thighs do not press on
the front of the cushion, and drive the prescribed input without a break
through each run; a warm-up of up to 10 min helps. Repeat until three
consecutive runs give seat values within ± 5 % of their mean, with the platform
inside its input tolerances. The mean of those seat values is $a_\mathrm{wS}$
and the mean of the platform values from the same runs is $a_\mathrm{wP}$, one
pair per test person, since Clause 11 asks each of them to pass. Report the
run-in duration, the disc, the masses of the test persons and the SEAT factor
or the corrected magnitude.

## 2. Correcting to the input that was intended

A simulator does not reproduce its target spectrum exactly. Clause 10.2.3
scales the magnitude measured on the seat by the ratio between the input the
test intended and the input it actually delivered:

$$
a^{*}_\mathrm{wS} = \frac{a_\mathrm{wS}\, a^{*}_\mathrm{wP}}{a_\mathrm{wP}}
= \mathrm{SEAT} \cdot a^{*}_\mathrm{wP}
$$

```python
from phonometry import vibration

test = vibration.seat_transmission([0.72, 0.70, 0.71], [1.02, 1.00, 0.99])

# The platform delivered 1.003 m/s2 where 1.10 was intended.
print(round(test.corrected_acceleration(1.10), 3))     # 0.778

# The correction does nothing when the simulator hit its target:
print(round(test.corrected_acceleration(test.platform_acceleration), 3))
# 0.71
```

The standard prints that correction twice and only one printing is right.
Formula (4), the one shown above, is correct. Formula (3) beside it carries an
asterisk on all four of its symbols and so reduces to
$a^{*}_\mathrm{wS} = a^{*}_\mathrm{wS}$, which corrects nothing; the reading
the library implements is the one the clause's own prose asks for. It is
recorded in the [errata](https://docs.jmrp.io/phonometry/reference/errata/).

## 3. The damping test

The other test in Clause 10 does not involve a person. Load the seat with an
inert mass of 75 kg ± 1 %, drive the base at the resonance frequency
$f_\mathrm{r}$ of the suspension, and take the ratio there (10.3):

$$
T = \frac{a_\mathrm{S}(f_\mathrm{r})}{a_\mathrm{P}(f_\mathrm{r})}
$$

```python
from phonometry import vibration

# A suspension that doubles what it is given, at its own frequency.
print(vibration.resonance_transmissibility(2.4, 1.2))   # 2.0
print(vibration.DAMPING_TEST_MASS_KG)                   # 75.0
```

The arithmetic is the SEAT arithmetic and the meaning is not. The SEAT factor
is a verdict over a whole spectrum with a person in the seat; $T$ is what the
seat does at the one frequency where it does the most, with an inert mass in
it. Clause 9.5.1 notes that the test may not suit a suspension with active
damping, and that a reduced mass of 60 kg has been found appropriate.

## 4. What the numbers are not

Clause 11 is short and worth reading before quoting any figure from this page
as a pass or a fail. This standard fixes the method and states **no acceptance
value at all**: the application standard written for the machine states them,
either as a maximum SEAT factor or as a maximum corrected magnitude on the
seat, and separately as a maximum transmissibility at resonance. `attenuates`
is therefore a statement about the seat, not a verdict about the machine.

## What this guide covers

- **Covered.** The **SEAT factor** of Formula (2), from the runs of one test, with the ± 5 %
  agreement 10.2.1 requires of three consecutive runs enforced rather than
  assumed.

- **Covered.** The **correction to an intended input** of 10.2.3, as Formula (4) with the
  SEAT factor substituted, which is what the clause's prose asks for and what
  its printed Formula (3) fails to say.

- **Covered.** The **transmissibility at resonance** of Formula (5), and the test masses of
  10.3 and 9.5.1.

- **Not covered.** **No acceptance values**, because the standard states none: Clause 11 leaves
  them to the application standard for the machine, and nothing here supplies a
  default. The input spectral classes those standards prescribe, such as the
  earth-moving machinery classes of ISO 7096, are not implemented either.

- **Not covered.** **Nothing weights a signal here.** The accelerations this page divides are
  already frequency-weighted; the weightings themselves, and the r.m.s.
  integration behind them, are in [human vibration
  exposure](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/).

- **Not covered.** **No laboratory.** The simulator tolerances of Clause 9, the transducer
  mounting of 5.2, the semi-rigid disc, the test persons and posture of 8.2, the
  run-in periods of 8.1.2 and the test report of Clause 12 are described in the
  standard and none of them is implemented: this page is the arithmetic that
  follows a test, not the test.

## See also

- [Human vibration exposure (ISO 2631, ISO 5349)](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/):
  the weightings and the daily exposure the seat is measured in service of.
- [Vibration with repeated shocks (ISO 2631-5)](https://docs.jmrp.io/phonometry/vibration/human/multiple-shock-vibration/):
  what a seat that bottoms out delivers to the spine.
- [Transfer stiffness of resilient elements (ISO 10846)](https://docs.jmrp.io/phonometry/vibration/structural/transfer-stiffness/):
  the same idea of a measured transmission ratio, applied to the isolator
  rather than to the seat.

## References

- **International Organization for Standardization. (2016).** [*Mechanical vibration — Laboratory method for evaluating vehicle seat vibration — Part 1: Basic requirements*](https://www.iso.org/standard/67659.html) (ISO 10326-1:2016).
  Clause 10: the SEAT factor of Formula (2), the three consecutive runs within ± 5 % of 10.2.1, the correction of 10.2.3 with Formulae (3) and (4), and the damping test of 10.3 with Formula (5) and its 75 kg inert mass. Clause 11 leaves the acceptance values to the application standard. The printed Formula (3) is an identity; see the errata.