# Multiple-shock whole-body vibration (ISO 2631-5)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/vibration/human/multiple-shock-vibration/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/vibration/human/multiple-shock-vibration/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-09
Updated: 2026-11-16T21:36:10Z
Standards: ISO 2631-5:2018
Verified: 6 conformance checks (ISO 2631-5:2018) https://docs.jmrp.io/phonometry/reference/conformance/#multiple-shock-whole-body-vibration-iso-2631-5
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Multiple shocks by ISO 2631-5:2018: the spinal model, seat-to-spine transfer, acceleration dose, compressive stress, R and lumbar-injury risk.

---

Vibration that contains repeated **mechanical shocks** (off-road vehicles,
high-speed marine craft, earth-moving machinery) loads the lumbar spine far
more than its equivalent r.m.s. level suggests. **ISO 2631-5:2018** predicts the
resulting spinal response and the risk of lumbar injury from the measured
vertical seat acceleration. phonometry implements the normative **Clause 5**
spinal-response model and the **Annex C** health-effect assessment. (The
Annex A / Annex E finite-element model is distributed by ISO as separate
software and is out of scope here.)

The boundary with the basic method is explicit. ISO 2631-1 declares its r.m.s.
evaluation normally sufficient up to a crest factor of 9, and offers the
running r.m.s./MTVV and the VDV beyond it; ISO 2631-5 is the additional method
for the regime past those, where the record contains repeated shocks. Its
clause 4 then splits that regime in two: *severe* conditions with possible
free fall or loss of contact with the seat and a dominant z-axis (military
off-road vehicles, high-speed marine craft) use the clause 5 model implemented
here, while *less severe* conditions in which the occupant stays seated
throughout (tractors, forestry and earth-moving machinery on rough ground)
belong to the Annex A finite-element model. In case of doubt the delineation
is quantitative: when the band-limited vertical peak acceleration exceeds
9.81 m/s² (1 g, the free-fall threshold), clause 5 and Annex C apply.

![Flow from the vertical seat acceleration az(t), conditioned as clause 5.1.3 requires with a second-order 0.01 Hz high pass and a fourth-order 80 Hz low pass and not with the ISO 2631-1 0.4 to 100 Hz filters, through the spinal response, the acceleration dose Dz and daily dose Dzd, the compressive stress Sd, the age-cumulated stress variable R, and the Weibull probability of lumbar injury](https://docs.jmrp.io/phonometry/media/diagram_iso2631_5.svg)

## 1. Getting the record (clauses 5.1.2 and 5.1.4)

Everything below starts from a measured $a_\mathrm{z}(t)$, and ISO 2631-5 adds four
acquisition requirements on top of the ISO 2631-1 ones, each of them specific to
shock exposure.

![Left: the seat pan in section with a seated occupant's ischial tuberosities resting on the ISO 10326-1 semi-rigid mounting disc of 250 plus or minus 50 mm diameter and at most 12 mm height, carrying a 75 plus or minus 5 mm by 1.5 mm metal disc for the accelerometers, taped to the cushion, with a contact switch beside it and the z axis positive to cranial, on a suspension seat. Right: a recorded acceleration with two shaded windows where contact is lost, excluded from the exposure, splitting the record into three contact segments that are conditioned separately. Below: the hardware requirements of clause 5.1.2 and the duration requirement of clause 5.1.4](https://docs.jmrp.io/phonometry/media/diagram_iso2631_5_setup.svg)

**Where (5.1.2).** $a_\mathrm{z}(t)$ is measured at the interface between the seat and
the **ischial tuberosities**. The measurement location on the seat and the
design of the accelerometer disc on the seat pad follow **ISO 10326-1**: a
semi-rigid moulded disc of 250 ± 50 mm diameter and at most 12 mm height, 80 to
90 durometer (A-scale), with a centre cavity holding a 75 ± 5 mm diameter,
1.5 mm thick metal disc that the accelerometers are attached to, taped to the
cushion so that the transducers sit midway between the tuberosities (5.2.3 of
that standard). The subject stays seated throughout data collection and does not
rise from the seat.

**Loss of contact (5.1.2).** Contact switches, video recordings or another
method detect loss of contact between the subject and the seat surface.
Accelerations measured while contact is lost **shall not be counted as
exposure**, and the loss of contact shall be detected and reported; the impact
on landing after a free fall (the motion of the person *and* of the seat)
shall be fully taken into account. This is the instrumentation that the
*severe* regime of clause 4 above actually requires, and it is what makes an
ISO 2631-5 record different from an ISO 2631-1 one.

**The chain (5.1.2).** The accelerometers and measuring equipment shall be
appropriate for the highest amplitudes anticipated over the measurement period.
The digitised record should have a flat acceleration response from 0.01 Hz to at
least 80 Hz, and a sampling rate of 256 samples per second or greater can be
necessary depending on the anti-aliasing method used, which is where the
`fs = 256.0` of the worked example below comes from. Details of the measurement
equipment, including the calibration method used, shall be provided.

**How long (5.1.4).** The record shall be long enough for the measured multiple
shocks to be typical of the exposure being assessed. Shock events may be
infrequent, so the duration has to be estimated from how variable the impacts
are: where a few severe shocks sit among many small ones, a longer record is
needed to have a reasonable probability of capturing them. A complete work cycle
is representative for a repeatable task such as a mine haul truck; for
non-repeatable ones (off-road travel, military transport) the sufficient
duration depends on the variability of the terrain. Trials that expose people to
repeated shock are likely to need a careful risk assessment, and shorter
measurements first may be appropriate to gain confidence that the exposure will
not be excessive.

## 2. Conditioning the record (clause 5.1.3)

The conditioning is six ordered steps, and two of them contradict the advice a
reader would otherwise give themselves.

1. **Check the sign.** The whole method is about *compressive* spinal loading,
   so the z axis must be positive to cranial: upward positive, in the
   basicentric system for seated persons. A sign error inverts which peaks are
   counted.
2. **Cut out the parts with no contact** between the accelerometer disc on the
   seat pad and the subject. This splits the record into separate parts, and the
   remaining steps are applied to each part **separately**.
3. **Check the anti-aliasing** if the data were resampled after acquisition.
   NOTE 1 warns that common data-processing packages apply suitable filters
   automatically, but that it is important to verify that they did.
4. **Offset-correct** so that the recorded acceleration reads (0 ± 0.1) m/s²
   with the accelerometer at rest (or with a symmetric signal). The clause then
   adds the warning: subtraction of the mean **may not be appropriate** if the
   recorded acceleration is asymmetric, and a shock record is asymmetric by
   construction, which is exactly the case a mean subtraction gets wrong.
5. **Consider a taper** if the accelerometer was in motion at the start or the
   end of the recording: the clause says that tapering the signal, with a cosine
   taper over several seconds for instance, may be appropriate before the band
   limiting. A record that starts and ends at rest is band-limited as it is.
6. **Band-limit** with a second-order Butterworth high pass at 0.01 Hz and a
   fourth-order Butterworth low pass at 80 Hz. The band-limiting and weighting
   filters of ISO 2631-1 should **not** be applied.

The last step is where the number is won or lost. NOTE 2 gives the reason in
numbers: free-fall periods above 0.5 s have been observed on fast naval craft,
and a 0.5 Hz high pass drags the −1 g of the free fall back to zero before the
impact arrives, so the impact peak is offset by up to +1 g and the calculated
dose is wrong by of order 10 %. Abrupt changes in terrain contour can do the
same. The 0.01 Hz corner exists to keep the free fall in the record.

```python
import numpy as np
from scipy.signal import butter, filtfilt

# The clause 5.1.3 band limiting, on a record already offset-corrected and
# split at the loss-of-contact boundaries.
fs = 256.0
high = butter(2, 0.01, "high", fs=fs, output="sos")   # 2nd order, 0.01 Hz
low = butter(4, 80.0, "low", fs=fs, output="sos")     # 4th order, 80 Hz
print(high.shape, low.shape)                          # (1, 6) (2, 6)
```

## 3. Spinal response (clause 5.2)

A seat-to-spine transfer function $H(f)$ (one complex zero and six complex
poles, unity transmissibility at 0 Hz and a resonance near 5 Hz) maps the
conditioned seat acceleration to the vertical spinal response $A_\mathrm{z}(t)$
(Formula 1/2):

$$
A_\mathrm{z}(t) = \mathcal{F}^{-1}\!\left[H(f)\,\mathcal{F}[a_\mathrm{z}(t)]\right].
$$

The conditioning of section 2 is not optional here: because $H$ is unity at
0 Hz by design, a DC offset (the 1 g gravity component of a DC-coupled
accelerometer, say) passes straight into $A_\mathrm{z}(t)$ and corrupts the positive
response peaks the dose is built from.

```python
from phonometry import vibration

# The transmissibility peaks near the ~5 Hz spinal resonance.
print(round(abs(vibration.seat_to_spine_transfer([2.0])[0]), 2))  # 1.06
print(round(abs(vibration.seat_to_spine_transfer([5.0])[0]), 2))  # 1.54
```

## 4. Acceleration dose (clause 5.3)

The **acceleration dose** combines the positive response peaks $A_{\mathrm{z},i}$
(each the maximum between two consecutive zero crossings) with a sixth-power
law, so the largest shocks dominate (Formula 3):

$$
D_\mathrm{z} = 1.07\left(\sum_i A_{\mathrm{z},i}^{\,6}\right)^{1/6}.
$$

The 1.07 is not a calibration fudge: NOTE 1 to clause 5.3 says that Formula (1)
represents the frequency response of the spine as a filter, and that the spine
also has an *amplitude* response function, which is what the 1.07 carries. Only
positive peaks are counted, and the sixth power has an operational corollary the
standard states outright: acceleration peaks lower than the highest by a factor
of three or more do not contribute significantly to Formula (3). A day's dose is
therefore decided by a handful of impacts, which is also why the peak count is
robust to how the zero-crossing rule treats the small stuff.

A daily dose scales the measured dose to the daily exposure time $t_\mathrm{d}$ over
the measurement time $t_\mathrm{m}$ (Formula 4): $D_\mathrm{zd} = D_\mathrm{z}\,(t_\mathrm{d}/t_\mathrm{m})^{1/6}$. To
compare different exposures the standard recommends $t_\mathrm{d}$ = 8 h.

```python
from phonometry import vibration

# Five 40 m/s2 response peaks in a day (the Annex C worked example).
print(round(vibration.dose_from_peaks([40.0] * 5), 2))  # 55.97  m/s2
```

![Two stacked panels over the same 8 s off-road seat record at 256 samples per second. Top: the conditioned seat acceleration and the spinal response overlaid, with each impact turned into a ringing response, and a 0.4 s free fall clamped at minus 9.81 metres per second squared before the largest impact. Bottom: the same spinal response with its 28 counted positive peaks marked, a dashed line at a third of the largest peak, and the three largest peaks annotated with their share of the sixth-power sum: 30.3 gives 98.6 percent, 14.7 gives 1.3 percent and 9.2 gives 0.1 percent, for an acceleration dose of 32.5 metres per second squared](https://docs.jmrp.io/phonometry/media/spinal_response_peaks.svg)

*What clause 5 does to a record, in the domain it does it in. The seat-to-spine
filter is resonant, so a sharp seat impact becomes a ringing spinal response
whose peak arrives later and looks nothing like the input; the zero-crossing
rule then counts 28 positive peaks; and the sixth power hands 98.6 % of the dose
to one of them. Everything below a third of the largest peak (the dashed line)
is contributing hundredths of a percent, which is the rule of clause 5.3 made
visible. `MultipleShockResult.peaks` holds exactly the marked values.*

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
# `vibration` is the namespace imported in the snippet of section 3.

fs_rec, duration = 256.0, 8.0
time = np.arange(int(duration * fs_rec)) / fs_rec
rng = np.random.default_rng(11)
seat = 1.5 * np.sin(2 * np.pi * 3.6 * time) + 0.45 * rng.standard_normal(time.size)
for start, amplitude in ((1.15, 26.0), (3.05, 8.0), (5.60, 55.0), (6.95, 15.0)):
    hit = time >= start
    seat[hit] += amplitude * np.exp(-20.0 * (time[hit] - start)) * np.sin(
        2 * np.pi * 5.5 * (time[hit] - start))
seat[(time >= 5.18) & (time < 5.58)] = -9.81      # 0.4 s of free fall

response = np.asarray(vibration.spinal_response(seat, fs_rec))
peaks = np.asarray(vibration.response_peaks(response))
shares = 100.0 * peaks**6 / float(np.sum(peaks**6))
print(peaks.size, round(float(peaks.max()), 1), round(float(shares.max()), 1))
# 28 30.3 98.6

fig, (ax_t, ax_p) = plt.subplots(2, 1, sharex=True, figsize=(11, 7.6))
ax_t.plot(time, seat, lw=0.9, color="#9e9e9e", label=r"$a_\mathrm{z}(t)$")
ax_t.plot(time, response, lw=1.5, color="#1f77b4", label=r"$A_\mathrm{z}(t)$")
ax_p.plot(time, response, lw=1.2, color="#1f77b4")
ax_p.axhline(peaks.max() / 3.0, ls="--", color="#2ca02c")
ax_t.legend(loc="upper left")
ax_p.set_xlabel("Time [s]")
plt.show()
```

## 5. Injury risk (Annex C)

The daily dose becomes a daily **compressive stress** $S_\mathrm{d} = m_\mathrm{z}\,D_\mathrm{zd}$
(Formula C.1), where $m_\mathrm{z}$ (0.029 MPa per m/s² for an 82 kg male, 0.025 for a
64 kg female) converts acceleration to vertebral stress. The stress accumulates
over the exposure years against the ageing spine's reducing ultimate strength
$S_\mathrm{u} = 6.75\ \mathrm{MPa} - S_{\mathrm{age}}\,(b+i)$ (Formulae C.3/C.4):

$$
R = \left[\sum_{i=0}^{n-1}
\left(\frac{S_\mathrm{d}\,N^{1/6}}{S_{\mathrm{u},i} - S_{\mathrm{stat}}}\right)^{6}\right]^{1/6},
$$

where $b$ is the age at which the exposure started, $n$ the number of exposure
years, $i$ the year counter $0 \le i \le n-1$ (so $S_{\mathrm{u},i}$ is the ultimate
strength at age $b+i$), and $N$ the number of exposure days per year.
$S_{\mathrm{stat}} = m_\mathrm{z} \times 9.81\ \mathrm{m/s^2}$ is the static compressive
stress the spine already carries under gravity: 0.284 MPa for the male $m_\mathrm{z}$,
0.245 MPa for the female one (`vibration.static_stress`), and
$S_{\mathrm{age}}$ is the annual loss of ultimate strength, 0.052 MPa/year for
males and 0.039 MPa/year for females (`vibration.ultimate_strength`, which
returns 5.71 MPa at age 20 and 4.67 MPa at age 40 for a male). The denominator
is therefore a *margin*: $R$ grows both because the dose accumulates day after
day and because that margin shrinks by $S_{\mathrm{age}}$ every year, so the
same daily dose is more damaging to an older spine.

A Weibull model turns $R$ into the probability of lumbar injury (Formula C.5):

$$
\Pi(R) = 1 - \exp\!\left[-\left(\frac{R}{\alpha}\right)^{\beta}\right].
$$

```python
from phonometry import vibration

# Annex C worked example: 5 x 40 m/s2/day, 82 kg male, age 20 for 20 years,
# 120 days/year.
dz = vibration.dose_from_peaks([40.0] * 5)
sd = vibration.compression_dose(dz)                     # 1.62 MPa
r = vibration.injury_risk(sd, start_age=20, exposure_duration_years=20, days_per_year=120)
print(round(r, 2))                               # 1.22
print(round(100 * vibration.injury_probability(r)))     # 37  % risk of injury
```

### Reading $R$ (Table C.2)

$R$ has no units and no meaning until it is put on the Table C.2 scale, which
gives the value associated with a 10 %, 50 % and 90 % risk of injury for each
sex:

| Risk of injury | 10 % | 50 % | 90 % |
| :--- | :--- | :--- | :--- |
| Male | 0.72 | 1.42 | 2.17 |
| Female | 0.52 | 0.87 | 1.20 |

The four bands those thresholds cut out are the ones the fiche of section 6
prints: below the 10 % value a **low** probability of an adverse health effect,
between 10 % and 50 % a **moderate** one, between 50 % and 90 % a **high** one,
and above the 90 % value a **very high** one. The male example above, $R$ = 1.22,
sits in the moderate band, which is what the standard's own worked example
concludes.

**The default matters.** `compression_dose` takes `mz` and `injury_risk` takes
`sex`, and both default to the male values. Running the *same exposure* for a
64 kg female subject does not merely change the number, it changes the verdict:

```python
for sex, mz in (("male", 0.029), ("female", 0.025)):
    sd_sex = vibration.compression_dose(dz, mz=mz)
    r_sex = vibration.injury_risk(sd_sex, start_age=20, exposure_duration_years=20,
                                  days_per_year=120, sex=sex)
    print(sex, round(sd_sex, 2), round(r_sex, 2),
          round(100 * float(vibration.injury_probability(r_sex, sex=sex))))
# male   1.62 1.22 37   -> moderate  (10 % < risk < 50 %)
# female 1.40 0.96 64   -> high      (50 % < risk < 90 %)
```

The lower compressive stress lands in the higher band, because the female
thresholds of Table C.2 are lower still. NOTE 5 of Annex C records the same
result for this exposure and quotes $R$ = 0.97 against the 0.96 computed here.
Its printed $S_\mathrm{d}$ is the 1.40 MPa computed here too, so the slip is the
last digit of the printed $R$, as the
[errata registry](https://docs.jmrp.io/phonometry/reference/errata/) records; the band, and
therefore the verdict, is the same. The $\alpha$ and $\beta$ coefficients of Formula (C.5) and the Table C.2
thresholds for female subjects rest on a smaller data set, as the standard
footnotes both tables.

From a measured time history the whole chain is one call:

```python
import numpy as np
from phonometry import vibration

# A synthetic 10 s seat record at 256 Hz with five 60 m/s2 shocks (stand-in
# for a measured az(t)).
fs = 256.0
az = np.zeros(2560)
az[256::512] = 60.0
result = vibration.multiple_shock_assessment(
    az, fs, start_age=20, exposure_duration_years=20, days_per_year=120, sex="male",
    measurement_time=10.0,      # t_m: the record is 10 s long
    exposure_time=4 * 3600.0,   # t_d: 4 h a day in this vehicle
)
print(round(result.acceleration_dose, 2))  # 20.94  m/s2, over the 10 s record
print(round(result.daily_dose, 2))         # 70.35  m/s2, Formula 4 scaled to td
print(round(result.risk, 2))               # 1.53
print(round(result.probability, 2))        # 0.58

result.plot()   # the injury-probability curve with this assessment's R marked (needs matplotlib)
```

`exposure_time` and `measurement_time` are what implement Formula 4 here.
Omitted, the measured dose is taken unchanged as the daily dose, which is only
correct when the record already covers the whole daily exposure: for this 10 s
record and a 4 h day that shortcut divides the dose by
$(t_\mathrm{d}/t_\mathrm{m})^{1/6} = 3.36$ and reports $R = 0.46$ instead of $1.53$, a 3 %
probability of injury where the exposure gives 58 %.

![Left: the seat-to-spine transmissibility rising to about 1.6 near a 5 Hz resonance then rolling off to near zero by 80 Hz. Right: the Weibull probability of lumbar injury versus the stress variable R for male and female, with the 10, 50 and 90 percent risk levels and the Annex C male example at R = 1.22, about 37 percent](https://docs.jmrp.io/phonometry/media/multiple_shock.svg)

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from phonometry import vibration

fig, (ax_h, ax_r) = plt.subplots(1, 2, figsize=(12.5, 5.4))

# Left: the seat-to-spine transfer function magnitude (Formula 1).
f = np.logspace(np.log10(0.5), np.log10(80.0), 400)
ax_h.plot(f, np.abs(vibration.seat_to_spine_transfer(f)), label="|H(f)|")
ax_h.set_xscale("log")
ax_h.set_xlabel("Frequency [Hz]")
ax_h.set_ylabel("Transmissibility  seat -> spine")
ax_h.legend()

# Right: the Weibull injury probability for both sexes, with the Annex C
# male example (five 40 m/s2 response peaks a day) marked, which is the R
# the figure prints - not the R of the 10 s synthetic record above.
grid = np.linspace(0.0, 3.0, 300)
for sex in ("male", "female"):
    ax_r.plot(grid, 100.0 * vibration.injury_probability(grid, sex=sex), label=sex)
sd = vibration.compression_dose(vibration.dose_from_peaks([40.0] * 5))
r = vibration.injury_risk(sd, start_age=20, exposure_duration_years=20, days_per_year=120)
for level, r_level in zip((10, 50, 90), (0.72, 1.42, 2.17)):  # Table C.2, male
    ax_r.axhline(level, color="#7f7f7f", linestyle=":", lw=0.8)
    ax_r.plot([r_level, r_level], [0.0, level], color="#7f7f7f", linestyle=":", lw=0.8)
ax_r.scatter([r], [100.0 * vibration.injury_probability(r)], marker="*", s=160,
             label=f"Example  R = {r:.2f}")
ax_r.set_xlabel("Stress variable R")
ax_r.set_ylabel("Probability of lumbar injury [%]")
ax_r.legend()
plt.show()
```

The `MultipleShockResult` carries the dose $D_\mathrm{z}$, the daily dose $D_\mathrm{zd}$, the
compressive stress $S_\mathrm{d}$, the stress variable $R$, the injury probability and
the response peaks, and its `.plot()` draws the injury-probability curve with
the 10/50/90 % risk thresholds of Table C.2. The model is vertical-axis only:
clause 4 neglects the horizontal contributions to spinal compression by design,
and the horizontal spinal model of the withdrawn 2004 edition is not reinstated,
so horizontal whole-body exposure is assessed instead with the r.m.s.,
running-r.m.s./MTVV and VDV metrics of
[Human Vibration](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/) (ISO 2631-1).

## 6. The health-risk report

The dose chain exists to be written down and read against the Annex C guidance.
`MultipleShockResult.report()` writes a one-page PDF health-risk assessment
sheet: the standard-basis line (Clause 5 spinal response and the Annex C risk
model), an optional metadata header (client, subject, workplace/vehicle,
instrumentation, calibration), the exposure-scenario grid (subject sex, the age
$b$ at which the exposure started, the number of exposure years $n$, the number
of exposure days per year $N$ and the number of counted response shocks), and
the dose-and-stress analysis table with the acceleration dose $D_\mathrm{z}$ (Formula 3),
the daily dose $D_\mathrm{zd}$ (Formula 4), the daily compressive stress $S_\mathrm{d}$
(Formula C.1), the cumulative stress variable $R$ (Formula C.3) and the
probability of lumbar injury $\Pi$ (Formula C.5).

Because ISO 2631-5:2018 defines no exposure limit, the fiche carries a
risk-band **zone row** rather than a PASS/FAIL verdict: the boxed $R$ and $\Pi$
name the Annex C risk classification, and a classification table places $R$
among the Table C.2 stress variables for $10$ / $50$ / $90$ % risk of injury
(low / moderate / high / very high probability of an adverse health effect),
with the injury-probability chart above it. `language="es"` renders the Spanish
fiche (comma decimals).

The `metadata` argument accepts a `ReportMetadata` whose relevant fields for a
multiple-shock report are `client`, `specimen` (the subject), `test_room` (the
workplace or vehicle), `test_date`, `instrumentation`, `calibration`, and the
footer identity `laboratory`, `operator`, `report_id` and `notes`.

```python
import numpy as np
from phonometry import vibration, ReportMetadata

# The Annex C worked example: five 40 m/s2 spinal-response shocks per day,
# 82 kg male, exposed from age 20 for 20 years at 120 days/year. The record is
# rebuilt from those response peaks (the standard states the example in terms
# of the peaks), so the fiche prints the published Annex C values. The five
# peaks are the whole day, so td = tm and daily_dose is dz unscaled.
peaks = np.array([40.0] * 5)
dz = vibration.dose_from_peaks(peaks)
sd = vibration.compression_dose(dz)
r = vibration.injury_risk(sd, start_age=20, exposure_duration_years=20, days_per_year=120)
result = vibration.MultipleShockResult(
    sex="male",
    acceleration_dose=dz,
    daily_dose=dz,
    compression_dose=sd,
    risk=r,
    probability=float(vibration.injury_probability(r)),
    start_age=20.0,
    exposure_duration_years=20,
    days_per_year=120.0,
    peaks=peaks,
    risk_thresholds=(0.72, 1.42, 2.17),   # Table C.2, male: 10 / 50 / 90 % risk
)

result.report(
    "multiple_shock.pdf",
    metadata=ReportMetadata(
        client="Example transport operator",
        specimen="82 kg male operator (seated)",
        test_room="Off-road vehicle, driver's seat",
        report_id="EXAMPLE-2631-5",
    ),
)   # R = 1.22, Pi = 37 % -> moderate probability of an adverse health effect
```

Rendering needs reportlab and, for the figure the fiche embeds, matplotlib
(`pip install "phonometry[report,plot]"`). The example fiche is regenerated with `make reports` and kept rendered in the repository; click the
preview to open the PDF.

**Report:** [Whole-body multiple-shock health-risk example report (PDF)](https://docs.jmrp.io/phonometry/media/iso2631_5_multiple_shock_example.pdf): One-page whole-body multiple-shock health-risk assessment fiche: a header with the transport operator, the subject and the off-road vehicle, the exposure-scenario grid (82 kg male, age 20, 20 years, 120 days per year, five counted shocks), the dose-and-stress analysis table with the acceleration dose Dz = 55.97 m/s2, the daily compressive stress Sd = 1.62 MPa, the cumulative stress variable R = 1.22 and the probability of lumbar injury 37 percent, the injury-probability curve with the Table C.2 risk levels and this assessment marked, the boxed R = 1.22 and 37 percent classed as a moderate probability of an adverse health effect, and the Annex C classification table where the moderate band (10 to 50 percent risk of injury) is the assessment's band.

Whole-body multiple-shock health-risk fiche (MultipleShockResult.report), the ISO 2631-5:2018 Annex C worked example with the dose-and-stress analysis and the Table C.2 risk classification.

## What this guide covers

- **Covered.** ISO 2631-5:2018 clause 5 and Annex C. The acquisition and conditioning
  requirements of clauses 5.1.2 to 5.1.4 as guidance; the clause 5.2
  seat-to-spine transfer function (`seat_to_spine_transfer`, `spinal_response`,
  `response_peaks`); the clause 5.3 acceleration dose and the Formula 4 daily
  dose (`dose_from_peaks`, `acceleration_dose`, `daily_dose`, and the
  `measurement_time` / `exposure_time` pair of `multiple_shock_assessment`); and
  the Annex C compressive stress, cumulative stress variable and Weibull
  probability with their Table C.1 coefficients and Table C.2 thresholds
  (`compression_dose`, `static_stress`, `ultimate_strength`, `injury_risk`,
  `injury_probability`, `multiple_shock_assessment`,
  `MultipleShockResult.report`).

- **Not covered.** The Annex A / Annex E finite-element model for the *less severe* exposures of
  clause 4 (occupants who stay seated throughout, which is most agricultural
  and earth-moving work) is distributed by ISO as separate software and is not
  implemented here; a record from that regime has no route through this page.
  Neither is the horizontal spinal model of the withdrawn 2004 edition, so
  horizontal whole-body exposure goes to the r.m.s., running-r.m.s./MTVV and VDV
  metrics of [Human Vibration](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/).
  The conditioning chain of section 2 is the caller's: `spinal_response` assumes
  a record that has already been sign-checked, split at the loss-of-contact
  boundaries, offset-corrected, tapered if its accelerometer was moving at its
  start or end and a taper was judged appropriate, and band-limited.

## See also

- [Human Vibration](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/): the ISO 2631-1 chain this page hands back to for the horizontal axes, and the crest factor and clause 6.3.3 ratios that decide whether a record belongs here at all.
- API reference: [`vibration.human.multiple_shock`](https://docs.jmrp.io/phonometry/reference/api/vibration/multiple-shock/).
- Theory: [Multiple shocks (ISO 2631-5)](https://docs.jmrp.io/phonometry/reference/theory/vibration/#multiple-shocks-iso-2631-5): the ISO 2631-5 response model, the acceleration dose and the Weibull risk law.

## References

- **Griffin, M. J. (1996).** [*Handbook of human vibration*](https://shop.elsevier.com/books/handbook-of-human-vibration/griffin/978-0-12-303041-2). Academic Press.
  ISBN 978-0-12-303041-2. Background on whole-body shock exposure, spinal biodynamics and the lumbar health effects that the ISO 2631-5 dose model quantifies.
- **International Organization for Standardization. (2016).** [*Mechanical vibration — Laboratory method for evaluating vehicle seat vibration — Part 1: Basic requirements*](https://www.iso.org/standard/67659.html) (ISO 10326-1:2016).
  The accelerometer disc on the seat pad that clause 5.1.2 requires: its diameter, height and hardness, and the metal disc that carries the transducers (5.2.3).
- **International Organization for Standardization. (2018).** [*Mechanical vibration and shock — Evaluation of human exposure to whole-body vibration — Part 5: Method for evaluation of vibration containing multiple shocks*](https://www.iso.org/standard/50905.html) (ISO 2631-5:2018).
  The acquisition and conditioning of the record (clauses 5.1.2 to 5.1.4), the seat-to-spine transfer function (clause 5.2, Formula 1), the acceleration and daily dose (clause 5.3, Formulae 3-5) and the Annex C assessment of adverse health effects (Formulae C.1, C.3-C.5, Tables C.1/C.2).