# System measurement: Golay, shaped sweeps, inversion

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/signals/spectra/system-measurement/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/signals/spectra/system-measurement/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-21
Updated: 2026-11-16T21:36:13Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Impulse responses from Golay pairs with exactly noise-free deconvolution, sweeps shaped to a target spectrum, and Kirkeby-regularized inversion.

---

The [room-acoustics guide](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) recovers
impulse responses with the two ISO 18233 work-horses - the exponential sweep
and the MLS. This page adds the measurement-engineering layer around them,
from the transfer-function literature rather than a standard: **complementary
Golay pairs** (a third excitation whose deconvolution is *exactly* free of
correlation noise), **shaped sweeps** whose magnitude spectrum follows any
prescribed target while keeping a swept sine's crest factor, and the
**regularized inversion** of a measured response - the tool that turns a
measured loudspeaker or microphone response into a safe equalizer, and the
bridge between the two: the inverse of a measured response is the natural
target spectrum for the next measurement's sweep.

The two acquisition tools recover the response through their own
deconvolution: correlation with the pair for Golay, spectral division by the
sweep's spectrum for shaped sweeps. All three tools on this page sit in the same
two-channel frame the diagram draws: a generator drives the loudspeaker under
test, with one channel carrying the electrical reference and one the microphone.
They differ only in the excitation and the deconvolution. The Golay pair of
section 1 recovers the response by correlation with the codes; the shaped sweep
of section 2 by spectral division; and the broadband-noise route the diagram
itself annotates, which belongs to the
[electroacoustics guide](https://docs.jmrp.io/phonometry/devices/electroacoustics/electroacoustics/),
by the $H_1 = G_{xy}/G_{xx}$ estimator with a coherence that polices it. The
regularized inversion of section 3 then works on whichever measured response
comes out.

![Two-channel frequency-response measurement chain: a signal generator producing broadband noise or a sweep feeds a power amplifier and the loudspeaker under test, a measurement microphone picks up the acoustic output, channel 1 carries the electrical reference x(t) and channel 2 the microphone response y(t), dual-channel FFT analysis with Welch-averaged Hann segments at 50 percent overlap yields the spectra Gxx, Gyy and Gxy, and two result boxes give the H1 estimator Gxy over Gxx, unbiased with output noise, and the coherence gamma squared equal to the squared magnitude of Gxy over Gxx times Gyy, which is one for a noiseless linear path and drops with noise, distortion or a drifting, misaligned delay](https://docs.jmrp.io/phonometry/media/diagram_system_measurement.svg)

## 1. Complementary Golay pairs

A Golay pair is two binary sequences $a$ and $b$ of length $L = 2^n$, built by a
two-line recursion (Havelock Part I Ch. 6, Eq. (1)): starting from
$a_1 = (+1, +1)$ and $b_1 = (+1, -1)$, each step sets
$a_{k+1} = [\,a_k \mid b_k\,]$ and $b_{k+1} = [\,a_k \mid -b_k\,]$, doubling
the length every time; thus `golay_pair(14)` returns two codes of
$2^{14} = 16384$ samples. Their defining property is *algebraic*, not
approximate: the two periodic autocorrelations sum to

$$
\sum_j a_j a_{j+k} + b_j b_{j+k} \;=\;
\begin{cases} 2L & k = 0\\ 0 & k \ne 0, \end{cases}
$$

an exact delta (Eq. (2)). An MLS autocorrelation has a $-1$ residue at every
nonzero lag; the Golay sidelobes cancel identically. The measurement runs
each code in turn - play $a$ periodically, record one steady-state period,
then the same with $b$ - and sums the two circular cross-correlations
(Eq. (4)): for a noiseless linear time-invariant system the impulse response
comes back to machine precision, a closed-form identity the tests and the
[conformance report](https://docs.jmrp.io/phonometry/reference/conformance/) pin at `1e-13`.

```python
import numpy as np
from scipy import signal
from phonometry import room

fs = 48000
pair = room.golay_pair(14)                       # two 16384-sample codes

# Simulated measurement: play each code periodically and record one
# steady-state period of a room-like band-pass system.
b, a = signal.butter(2, [80.0, 12000.0], btype="bandpass", fs=fs)
length = pair[0].size
rec_a = signal.lfilter(b, a, np.tile(pair[0], 3))[2 * length:]
rec_b = signal.lfilter(b, a, np.tile(pair[1], 3))[2 * length:]

ir = room.golay_impulse_response(rec_a, rec_b, pair, fs=fs)
print(ir.method, ir.size)                   # golay 16384
ir.plot()
```

![The impulse response of a band-pass system recovered from a Golay pair over the first six milliseconds, drawn on top of the dashed true system response with no visible difference, and a note reading max recovered minus true equals 2.1e-14, noise-free closed-form identity](https://docs.jmrp.io/phonometry/media/golay_ir.svg)

*The Golay recovery of a band-pass system's impulse response: the summed
complementary correlations land on the true response to machine precision
(max error $2\cdot10^{-14}$ here), the closed-form identity the tests pin.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import signal
from phonometry import room

fs = 48000
pair = room.golay_pair(14)                       # two 16384-sample codes
b, a = signal.butter(2, [200.0, 2000.0], btype="bandpass", fs=fs)
length = pair[0].size
rec_a = signal.lfilter(b, a, np.tile(pair[0], 3))[2 * length:]
rec_b = signal.lfilter(b, a, np.tile(pair[1], 3))[2 * length:]

ir = room.golay_impulse_response(rec_a, rec_b, pair, fs=fs)

# One line — the recovered impulse response:
ir.plot()
plt.show()

# By hand, against the true system response:
impulse = np.zeros(length)
impulse[0] = 1.0
true_ir = signal.lfilter(b, a, impulse)
err = np.max(np.abs(np.asarray(ir) - true_ir))

t_ms = 1e3 * np.arange(length) / fs
view = t_ms <= 6.0
fig, ax = plt.subplots()
ax.plot(t_ms[view], np.asarray(ir)[view], label="Recovered IR")
ax.plot(t_ms[view], true_ir[view], "r--", label="True system response")
ax.set(xlabel="Time [ms]", ylabel="Amplitude",
       title=f"max |recovered - true| = {err:.1e}")
ax.legend()
plt.show()
```

The result is the same
[`ImpulseResponseResult`](https://docs.jmrp.io/phonometry/reference/api/rooms/impulse-response/) the sweep
and MLS front ends return, so everything downstream -
[room parameters](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/), decay curves,
[STI](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/) - consumes it unchanged.
Recordings spanning several periods are synchronously averaged, so
uncorrelated background noise falls by 3 dB per doubling while the
deterministic part stays exact. The trade-offs mirror the MLS: the recovery
is circular (the system must decay within one code period, or an
`ImpulseResponseWarning` flags the aliased tail), distortion products smear
across the period instead of separating like a sweep's, and the two
sequential steady states make the pair the most exposed of the family to time
variance (Xiang's Sec. 2) - the price of the exact complementarity.

### Running the pair

The snippet above fakes the acquisition with `lfilter`, which quietly assumes a
sample-accurate, zero-latency loop. A real run has four decisions.

**Emission.** Play each code back to back and **discard at least one whole
period** before keeping anything, so the system reaches the periodic steady
state the circular correlation assumes (the same condition the aliasing warning
enforces, seen from the other side). Then keep a whole number of periods, and
repeat for the second code without touching gain or geometry.

**Alignment, which is the one that fails silently.** The recovery is a circular
cross-correlation, so any latency between the emitted and recorded streams
appears as a *rotation* of the impulse response: annoying but recoverable. The
real damage is that **both recordings must be cut at the same offset**: the
exact complementarity only survives if the $a$ and $b$ records are aligned with
each other to the sample, and a one-sample discrepancy destroys the sidelobe
cancellation the whole method rests on, leaving a raised floor that looks like
noise. Get the offset once with a loopback channel: record the electrical drive
alongside the microphone and measure it with `time_delay` from the
[delay estimation](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/) page, then
apply the same cut to both.

**Level and background.** Set the amplifier so the code's peak leaves headroom
at both the loudspeaker and the converter: Golay codes are binary, so their
crest factor is the worst of the family, and clipping shows up as a raised noise
floor rather than as an obvious artefact. Record a period of silence first and
check that the response sits well above it, because the pair rejects noise only
by averaging periods.

**Time invariance,** which the page already names: keep the room closed, the
temperature steady, and run the two codes back to back rather than an hour
apart.

## 2. Sweeps with an arbitrary target spectrum

A sweep's energy at a given frequency can be set two ways: by its amplitude,
or by *how long it dwells there*. Müller & Massarani's frequency-domain
synthesis (Secs. 4.2-4.3) uses the second lever: define the target magnitude
$|H(f)|$, make the group delay grow in proportion to the target's power,

$$
\tau_\mathrm{G}(f) = \tau_\mathrm{G}(f - df) + C\,|H(f)|^2,\qquad
C = \frac{\tau_\mathrm{G}(f_\mathrm{end}) - \tau_\mathrm{G}(f_\mathrm{start})}{\sum |H(f)|^2},
$$

(Eqs. (11)-(12)), integrate the group delay into a phase, and inverse-FFT.
The sweep then follows *any* spectral shape with a nearly constant envelope,
keeping the crest factor close to a swept sine's ideal 3.01 dB - unlike a
noise signal with the same spectrum, which sits ~6 dB higher. `shaped_sweep_signal`
implements the construction with the paper's band-limiting and Nyquist-phase
details; `target` is `"pink"` (the classical room-measurement emphasis,
default), `"white"`, or any `(frequencies, magnitude_db)` pair:

```python
from phonometry import room

fs = 48000
sweep = room.shaped_sweep_signal(fs, 50.0, 5000.0, 2.0, target="pink")
print(round(sweep.crest_factor_db, 1))      # 4.2 (dB; the ideal is 3.02)
sweep.plot()
```

![Two panels for a pink shaped sweep from 50 hertz to 5 kilohertz: the time-domain waveform with a nearly constant envelope over two seconds, and below it the Welch spectrum of the sweep falling three decibels per octave exactly on top of the dashed pink target line inside the shaded sweep band](https://docs.jmrp.io/phonometry/media/shaped_sweep.svg)

*The two panels are the same statement seen twice. The envelope is flat because
the shape was bought with dwell time rather than amplitude, which is why the
crest factor is 4.22 dB, 1.2 dB above the swept sine's ideal 3.01 and about
6 dB below shaped noise of the same spectrum. The measured Welch spectrum fits
−3.013 dB/octave and stays within 0.74 dB of the pink target across the whole
50 Hz-5 kHz band, so what the amplifier sees is the target and not an
approximation of it.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import signal as sp_signal
from phonometry import room

fs = 48000
res = room.shaped_sweep_signal(fs, 50.0, 5000.0, 2.0, target="pink")
x = np.asarray(res)

nperseg = 8192   # 75 % overlap: 50 % would ripple ~2 dB on a sweep
freqs, psd = sp_signal.welch(x, fs=fs, nperseg=nperseg,
                             noverlap=3 * nperseg // 4)
welch_db = 10.0 * np.log10(psd)
welch_db -= welch_db[(freqs >= 50.0) & (freqs <= 5000.0)].max()
target_db = 20.0 * np.log10(np.maximum(res.magnitude, 1e-300))
target_db -= target_db[(res.frequencies >= 50.0)
                       & (res.frequencies <= 5000.0)].max()

fig, axes = plt.subplots(2, 1, figsize=(10, 7))
axes[0].plot(np.arange(x.size) / fs, x, lw=0.5)
axes[0].set_xlabel("Time [s]")
axes[0].set_ylabel("Amplitude")
axes[1].semilogx(freqs[1:], welch_db[1:], lw=1.3, label="Welch spectrum")
axes[1].semilogx(res.frequencies[1:], target_db[1:], "r--",
                 label="Pink target (-3 dB per octave)")
axes[1].axvspan(50.0, 5000.0, alpha=0.08, label="Sweep band")
axes[1].set_xlabel("Frequency [Hz]")
axes[1].set_ylabel("Level re in-band max [dB]")
axes[1].set_ylim(-60.0, 8.0)
axes[1].legend()
plt.tight_layout()
plt.show()
```

The synthesis metadata travels with the result: `frequencies` and `magnitude`
are the exact band-limited magnitude imposed on the spectrum, `group_delay`
is the sweep's time-frequency trajectory, and `crest_factor_db` the achieved
peak-to-RMS ratio. The purpose of the shaping is signal-to-noise engineering:
matching the emitted spectrum to the ambient noise floor (or to a
loudspeaker's power-handling limits) buys a frequency-independent SNR that no
post-processing can recover (Müller & Massarani Sec. 3).

Deconvolution needs nothing new - the result acts as its own reference array
for the [spectral method](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) of
`impulse_response`, which divides the sweep's coloration out again:

```python
import numpy as np
from scipy import signal
from phonometry import room

fs = 48000
freqs = np.array([50.0, 200.0, 1000.0, 8000.0])
emphasis = np.array([12.0, 6.0, 0.0, 0.0])   # LF boost against rumble
sweep = room.shaped_sweep_signal(fs, 50.0, 8000.0, 3.0,
                                 target=(freqs, emphasis))

# Simulated measurement of a known system (replace with play/record):
b, a = signal.butter(2, [200.0, 4000.0], btype="bandpass", fs=fs)
excitation = np.concatenate([np.asarray(sweep), np.zeros(fs)])
recorded = signal.lfilter(b, a, excitation)

ir = room.impulse_response(recorded, excitation, fs, length=fs)
ir.plot()
```

The emphasis re-weights the measurement's noise floor, not the recovered
response. One subtlety inherited from the hard band-limiting: the
deconvolution's band-limiting kernel is zero-phase, so a small anticausal
tail sits at the very end of the full deconvolution buffer - keep
`return_full=True` when hunting for tenth-of-a-dB accuracy at the band edges.

### Choosing the target, the level and the duration

`emphasis = np.array([12.0, 6.0, 0.0, 0.0])` above is an assertion, not a
measurement. Five decisions turn it into one.

- **The target comes from the background.** Measure the background at the
  microphone position first with `power_spectral_density`, smooth it to third
  octaves, and use its *shape* plus the margin you want as the sweep target. The
  emitted spectrum then tracks the noise and the deconvolved response has a flat
  signal-to-noise ratio, instead of a good midrange and a useless bottom octave.
- **The duration follows from the margin you are short of.** Doubling the sweep
  length buys about 3 dB of SNR in the deconvolved response, so the duration is
  arithmetic, bounded above by the time-invariance of the system: a room with
  moving air, or a loudspeaker heating up, sets the ceiling long before the
  arithmetic does.
- **The record needs a tail.** The excitation must carry a silence at least as
  long as the system's decay after the sweep, which is what the `np.zeros(fs)`
  in the snippets above is for.
- **The low-frequency emphasis has a physical cap.** Driver excursion and
  amplifier headroom stop you long before the synthesis does. Raise the level
  until the response stops being linear and then back off: compare two runs 6 dB
  apart, and if the deconvolved responses differ, you were already past it.
- **Shaping does not cost the distortion separation.** That separation is a
  property of the sweep's *group delay*, not of its magnitude: the $k$-th
  harmonic of an instantaneous frequency $f$ arrives at the time the sweep
  passes $kf$, so as long as the group delay is monotonic (which the recursion
  guarantees for any non-zero target), the distortion products still deconvolve
  to times before the linear response. Shaping only changes how far before,
  because a target that dwells longer at low frequencies spreads the harmonic
  packets differently from the exponential sweep's constant per-octave dwell.
  [Swept-sine distortion](https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/)
  is where those separated packets are read.

## 3. Regularized spectral inversion

### Measuring the response you are going to invert

The inversion is only as good as its input, and a measured loudspeaker response
is not a synthetic band-pass. Measure on the reference axis at a stated distance
(1 m is the IEC 60268-5 convention the
[loudspeakers guide](https://docs.jmrp.io/phonometry/devices/electroacoustics/loudspeakers/) uses)
with a measurement microphone, in an anechoic room if you have one. If you do
not, put source and microphone as far from every surface as the room allows and
**time-gate the impulse response before the first reflection**. That gate sets
the lowest valid frequency: for a source and microphone 1.2 m above a hard floor
and 1 m apart, the floor reflection arrives 4.7 ms after the direct sound, so
the gated response is only valid above roughly $1/4.7\ \text{ms} \approx
210$ Hz. Set `f_range` inside the band the gate actually validated and let the
regularization cap everything outside it, because equalizing an ungated in-room
response builds the room's modes into the filter, and they move with the
microphone. Below the gate's limit, a ground-plane measurement is the usual
alternative.

![Two benches for a sweep measurement: panel (a) an audio interface driving an electrical device under test with a second interface channel wired straight back from the output as a loopback reference that fixes t equal to zero; panel (b) a loudspeaker and a measurement microphone both 1.20 m over a hard floor and 1.00 m apart, with the reflected path of 2.60 m dashed and the resulting reflection-free time of 4.7 ms stated; below both, the sweep's own time axis with the linear arrival at t equal to zero, the second and third harmonic pre-arrivals at minus 0.49 and minus 0.77 seconds, the per-order window of 8192 samples and the closest arrival spacing L ln(3/2) equal to 0.28 s](https://docs.jmrp.io/phonometry/media/diagram_sweep_bench.svg)

*Panel (b) is the bench of this section: source and microphone 1.20 m above a
hard floor and 1.00 m apart, so the reflected path is
$\sqrt{1.00^2 + 2.40^2} = 2.60$ m, 1.60 m longer than the direct one, and the
floor arrives $1.60/343 = 4.7$ ms late. The gate has to close before that, and a
4.7 ms window resolves nothing below about 210 Hz. Panel (a) is the electrical
counterpart, where a loopback channel fixes $t = 0$; the strip under both is the
harmonic time budget of the sweep that
[swept-sine distortion](https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/)
plays, and takes no part in the inversion.*

Equalizing with a measured response means inverting it, and a plain
reciprocal $1/H(f)$ explodes wherever the system radiates little energy (a
notch in-band, everything out-of-band), turning an equalizer into a noise
amplifier. Müller & Massarani confine the inversion with a band-pass
(Secs. 3.1, 4.5); the general form of that confinement is Kirkeby & Nelson's
frequency-dependent Tikhonov regularization,

$$
H_\mathrm{inv}(f) = \frac{H^*(f)}{|H(f)|^2 + \varepsilon(f)},
$$

with $\varepsilon(f)$ small inside the band to be equalized and large outside.
In-band the equalized magnitude $|H \cdot H_\mathrm{inv}|$ deviates from unity by
exactly $\varepsilon/(|H|^2 + \varepsilon)$ - a closed form the conformance
suite checks bin by bin - and out-of-band the filter gain can never exceed
$1/(2\sqrt{\varepsilon})$, the analytic maximum of $x/(x^2 + \varepsilon)$. A
modeling delay of half the filter block makes the generally anticausal inverse
of a mixed-phase response causal
(Kirkeby & Nelson Sec. 2.4).

```python
import numpy as np
from scipy import signal
from phonometry import signals

fs = 48000.0
# A loudspeaker-like measured response (replace with a measured IR).
b, a = signal.butter(2, [100.0, 8000.0], btype="bandpass", fs=fs)
imp = np.zeros(2048)
imp[0] = 1.0
h = signal.lfilter(b, a, imp)

inv = signals.regularized_inverse_filter(h, fs, f_range=(200.0, 4000.0))
print(round(inv.flatness_db, 5))    # 1e-05 (dB: in-band deviation from 0 dB)
print(round(inv.max_gain_db, 1))    # -6.0 (dB: capped out-of-band boost)
inv.plot()
```

![Magnitudes over log frequency for a regularized inversion of a band-pass response: the measured response in blue, the inverse filter in red mirroring it inside the shaded equalized band from 200 hertz to 4 kilohertz, and the equalized product in green reading exactly zero decibels across the band and rolling off outside it where the regularization caps the gain](https://docs.jmrp.io/phonometry/media/regularized_inversion.svg)

*The green curve is the whole test: inside the equalized band it departs from
0 dB by at most 9×10⁻⁶ dB, which is $\varepsilon/(|H|^2+\varepsilon)$ evaluated
bin by bin and not a fitted result. Outside it the red inverse stops rather than
climbing: the boost is capped at −6.03 dB relative to the in-band unity, the
analytic $1/(2\sqrt\varepsilon)$ maximum. A plain $1/H$ would run off the top of
this axis in the same two regions where the blue response runs off the bottom.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import signal
from phonometry import signals

fs = 48000.0
b, a = signal.butter(2, [100.0, 8000.0], btype="bandpass", fs=fs)
imp = np.zeros(2048)
imp[0] = 1.0
h = signal.lfilter(b, a, imp)

res = signals.regularized_inverse_filter(h, fs, f_range=(200.0, 4000.0))
f = res.frequencies[1:]
h_mag = np.abs(res.response_spectrum)[1:]
inv_mag = np.abs(res.spectrum)[1:]
peak = h_mag.max()

fig, ax = plt.subplots(figsize=(10, 6))
ax.semilogx(f, 20 * np.log10(h_mag / peak), label="Measured $|H|$")
ax.semilogx(f, 20 * np.log10(inv_mag * peak),
            label=r"Inverse $|H_{\mathrm{inv}}|$")
ax.semilogx(f, 20 * np.log10(h_mag * inv_mag), lw=1.8,
            label=r"Equalized $|H \cdot H_{\mathrm{inv}}|$")
ax.axvspan(200.0, 4000.0, alpha=0.08, label="Equalized band")
ax.set_ylim(-50.0, 15.0)
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Magnitude [dB]")
ax.legend()
plt.show()
```

Both regularization levels are fractions of the peak of $|H|^2$, generalising
the scalar `regularization` of `impulse_response`: `regularization_inside`
(default `1e-6`) sets how exactly the band is flattened,
`regularization_outside` (default `1.0`) caps the out-of-band boost 6 dB
*below* the in-band unity, and a geometric cross-fade over
`transition_octaves` (default 1/3) connects the two smoothly. The result's
`apply()` equalizes any recording with the modeling delay already removed,
and the function accepts an `ImpulseResponseResult` directly - its sample
rate rides along:

```python
import numpy as np
from scipy import signal
from phonometry import room, signals

fs = 48000
sweep = room.sweep_signal(fs, 50.0, 20000.0, 1.0)
excitation = np.concatenate([sweep, np.zeros(fs // 2)])
b, a = signal.butter(2, [100.0, 8000.0], btype="bandpass", fs=fs)
recorded = signal.lfilter(b, a, excitation)     # play/record in reality

ir = room.impulse_response(recorded, excitation, fs)  # any front end works
inv = signals.regularized_inverse_filter(ir, f_range=(200.0, 10000.0))
flat_recording = inv.apply(recorded)             # delay already removed
inv.plot()   # measured, inverse and equalized magnitudes (figure above)
```

### Inverting a measured response

Two habits separate a working equalizer from a noise amplifier.

**Smooth the magnitude first.** A sixth- to third-octave
`fractional_octave_smoothing` is the usual choice, so that the inverse targets
the trend rather than the nulls. A null is a local interference pattern: it
moves with the microphone, so it cannot be equalized anywhere except at that
point, and boosting it spends headroom to amplify noise.

**Regularize like a measurement, not like a synthetic.** On a measured response
`regularization_inside` belongs in the range 1e-3 to 1e-2, which limits the
in-band flattening to a few tenths of a decibel and caps the boost; the 1e-6
default that yields the 1e-5 dB flatness above only makes sense on a noiseless
synthetic response, and expecting that number from a real measurement is the
mistake. Read the two reported numbers accordingly: `flatness_db` is how flat
the band comes out, `max_gain_db` the worst-case boost the filter can ever
apply: the number to check against the amplifier's headroom before playing
anything through it.

The asymmetry practitioners rely on is worth stating outright: **cut deep and
boost shyly.** A peak is a resonance and exists everywhere; a dip is usually
interference and exists only at the microphone.

### Closing the loop: pre-emphasis from a measured response

The two halves of this page compose into Müller & Massarani's own workflow
(their Fig. 18): measure the loudspeaker, invert its response in the
transmission band, and hand the inverse magnitude to the sweep synthesis as
the target - the next measurement then radiates a *flat* acoustic spectrum,
with the equalization done by the excitation instead of by noise-amplifying
post-processing:

```python
import numpy as np
from scipy import signal
from phonometry import room, signals

fs = 48000.0
b, a = signal.butter(2, [100.0, 8000.0], btype="bandpass", fs=fs)
imp = np.zeros(2048)
imp[0] = 1.0
h = signal.lfilter(b, a, imp)                    # the measured response

inv = signals.regularized_inverse_filter(h, fs, f_range=(200.0, 4000.0))
target_db = 20.0 * np.log10(
    np.abs(inv.spectrum[1:]) * np.abs(inv.response_spectrum).max()
)
sweep = room.shaped_sweep_signal(int(fs), 200.0, 4000.0, 3.0,
                                 target=(inv.frequencies[1:], target_db))
sweep.plot()   # waveform and spectrum against the inverted-response target
```

## Relation to the other tools

The Golay pair joins `sweep_signal` and `mls_signal` in the
[ISO 18233 acquisition family](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/), and
the three differ on four axes that decide a real measurement:

| | Golay pair | Exponential sweep | MLS |
| :--- | :--- | :--- | :--- |
| SNR per unit time | all three are deterministic and gain 3 dB per doubling of measurement time, but the pair spends half its time on each code and so pays **3 dB** against a single sweep of the same total length | reference | as the pair, minus the second code |
| Distortion | smeared over the period as a noise-like floor | separated into a region *before* the linear response, where it can be read or discarded | smeared, as the pair |
| Time variance | the most fragile: two identical steady states are required, and drift raises the noise floor rather than producing an obvious error | a single pass, so only the pass has to be stationary | one periodic pass |
| Truncation | a decay longer than one period wraps onto the start (the aliasing warning above) | only needs enough silence appended | wraps, as the pair |

So: the sweep for distortion rejection, the MLS for legacy hardware, and the
pair when exact, correlation-noise-free deconvolution of a *stationary fixture*
matters (HRTF rigs, calibration fixtures): where 3 dB of signal-to-noise ratio
is cheap and the last decimal of the impulse response is what you came for. Harmonic analysis of what sweeps *discard* lives in
[swept-sine distortion](https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/). The Welch
machinery used to verify the shaped sweep is the
[calibrated spectral analysis](https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/) page,
and the equalized responses feed the same downstream chain as every
[impulse response](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/).

## What this guide covers

- **Covered.** The complementary Golay pair (Golay 1961; Havelock, Kuwano & Vorländer eds.,
  2008, Part I Ch. 6 by Xiang): the append recursion, the exact
  complementary-autocorrelation identity and the summed-correlation recovery,
  implemented by `golay_pair` and `golay_impulse_response`. The group-delay
  sweep synthesis of Müller & Massarani (2001, Secs. 4.2-4.3), implemented by
  `shaped_sweep_signal`. The frequency-dependent Tikhonov regularization of
  Kirkeby & Nelson (1999, Eq. 17 and Sec. 2.4), implemented by
  `regularized_inverse_filter`.

- **Not covered.** These are measurement-engineering methods from the transfer-function
  literature, not a certification standard, so there is no compliance clause to
  check against. Kirkeby & Nelson's original inversion targets multi-loudspeaker
  sound reproduction, with a matrix regularization for crosstalk cancellation
  between several channels. `regularized_inverse_filter` implements only the
  single-channel, scalar case of their Eq. 17.

## See also

- [Room acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the ISO 18233 sweep and MLS excitations the Golay pair sits beside.
- [Swept-sine distortion](https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/): reading the harmonic packets a sweep separates out.
- [Loudspeakers](https://docs.jmrp.io/phonometry/devices/electroacoustics/loudspeakers/): the reference axis, distance and free-field conditions the measured response needs.
- [Calibrated spectral analysis](https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/): the Welch machinery that verifies the shaped sweep, and the smoothing the inversion wants first.
- [Correlation and delay](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/): the loopback measurement that aligns the two Golay records.
- API reference: [`signals.inversion`](https://docs.jmrp.io/phonometry/reference/api/signals/inversion/).

## References

- **Golay, M. J. E. (1961).** Complementary series. *IRE Transactions on Information Theory*, *7*(2), 82-87. https://doi.org/10.1109/TIT.1961.1057620
  The original construction of the complementary pairs of §1.
- **Havelock, D., Kuwano, S., & Vorländer, M. (Eds.). (2008).** *Handbook of signal processing in acoustics*. Springer. https://doi.org/10.1007/978-0-387-30441-0
  Part I Chapter 6 (Xiang, Digital Sequences): the Golay recursion of §1, the complementary-autocorrelation identity of Eq. (2) and the frequency-domain recovery procedure of Eq. (4) and Fig. 2. ISBN 978-0-387-77698-9.
- **Kirkeby, O., & Nelson, P. A. (1999).** [Digital filter design for inversion problems in sound reproduction](https://aes.org/publications/elibrary-page/?id=12098). *Journal of the Audio Engineering Society*, *47*(7/8), 583-595.
  The frequency-dependent Tikhonov regularization of §3 (their Eq. (17)) and the modeling delay that makes the mixed-phase inverse causal (Sec. 2.4).
- **Müller, S., & Massarani, P. (2001).** [Transfer-function measurement with sweeps](https://aes.org/publications/elibrary-page/?id=10189). *Journal of the Audio Engineering Society*, *49*(6), 443-471.
  The sweep-synthesis chapter behind §2: frequency-domain construction from magnitude and group delay (Sec. 4.2), the group-delay recursion for arbitrary magnitude spectra (Sec. 4.3, Eqs. (11)-(12)) and the band-limited inversion discussion of Secs. 3.1 and 4.5. The extended "Director's Cut" edition was consulted.