# Calibrated spectral analysis

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/signals/spectra/spectral-analysis/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-17
Updated: 2026-10-21T12:42:48Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Welch spectra (Bendat & Piersol) with random errors, confidence intervals, coherent output, smoothing, colored noise and multitaper.

---

A spectrum without its uncertainty is half a measurement. This page covers the
Welch spectral estimators of `phonometry.signals` that report, next to the
spectrum itself, the statistical quality of the estimate following Bendat &
Piersol, *Random Data: Analysis and Measurement Procedures* (4th ed., 2010):
the **power spectral density** and **cross-spectral density** with the
effective number of averages, the normalized random error and chi-square
confidence intervals; the **coherent output spectrum** that splits a measured
output into the part linearly explained by the input and the noise remainder,
with the spectral signal-to-noise ratio; a **fractional-octave smoother** with
a constant-power kernel; and **colored-noise generators** with an exact
power-law slope for exercising all of the above. A **Thomson multitaper
estimator** (Percival & Walden, 1993) completes the family for records too
short to segment. Every error formula is a closed form from the sources,
verified by seeded Monte Carlo in the test suite.

## 1. Power spectral density with its statistical error

`power_spectral_density` estimates the one-sided autospectral density
$G_{xx}(f)$ by Welch's method: the record is split into tapered (Hann by
default), 50 %-overlapped segments whose periodograms are averaged. No
detrending is applied, so absolute calibration is preserved: a signal in
pascals yields Pa²/Hz. Two scalings are available: `'density'` (units²/Hz,
integrates to the signal power) and `'spectrum'` (units², reads the power of
discrete tones directly).

The price of preserving the calibration is that any DC offset or slow drift
stays in the record and leaks. The offset lands in the DC bin, and the Hann
taper's sidelobes spread a fraction of it over the first few bins, so an
uncorrected offset appears as a spurious low-frequency rise that no amount of
averaging removes. When the lowest bins matter, subtract the mean or high-pass
the record explicitly before the call (that is a change to the *signal*, not a
setting on the estimator), and note that the same offset is invisible in a
fractional-octave display, because no band reaches DC. The same condition
returns in
[Data qualification](https://docs.jmrp.io/phonometry/signals/metrology/data-qualification/), whose
level-crossing and peak statistics are written for a zero-mean process.

The estimator is a fixed pipeline: the window sets the resolution bandwidth,
and the effective averages follow from the record length (the raw segment
count) together with the window and overlap. Once those are fixed every
quality figure follows from the main design choice, the segment length. The
diagram traces it with the numbers of this page's example.

![Block diagram of the Welch PSD pipeline: a 20 second pink noise record at 48 kilohertz is split into 50 percent overlapped segments of 4096 samples giving 467 segments and an 11.7 hertz bin spacing, each segment is Hann tapered for a resolution bandwidth of 17.6 hertz, the one-sided squared FFT periodograms are averaged into 442 effective averages, and the result is Gxx of f with a chi-square confidence interval, a random error of 1 over the square root of n d equal to 4.8 percent and about 885 degrees of freedom; a final note states the trade-off that longer segments buy resolution but spend averages](https://docs.jmrp.io/phonometry/media/diagram_spectral_analysis.svg)

Averaging $n_\mathrm{d}$ independent segments gives the estimate $2 n_\mathrm{d}$ chi-square
degrees of freedom (Eq. 8.162), from which everything else follows:

$$
\varepsilon_\mathrm{r}[\hat{G}_{xx}] = \frac{1}{\sqrt{n_\mathrm{d}}}, \qquad
\frac{n\,\hat{G}_{xx}}{\chi^2_{n;\,\alpha/2}} \le G_{xx} \le
\frac{n\,\hat{G}_{xx}}{\chi^2_{n;\,1-\alpha/2}}, \quad n = 2 n_\mathrm{d} .
$$

With overlapped, tapered segments the averages are correlated, so the result
reports both the raw segment count (`n_segments`) and the **effective**
number of independent averages (`n_averages`), computed with the
window-correlation formula of Welch (1967) that Bendat & Piersol reference in
Section 11.5.2.2; for a Hann taper at 50 % overlap it is roughly 0.95 of the raw
count. The random error and the confidence interval use the effective value.
At DC, and at Nyquist for an even segment length, the one-sided spectrum
has a single real Fourier component, so those bins carry half the degrees of
freedom and a correspondingly wider interval.

```python
from phonometry import signals

# record: one channel of a calibrated capture, in pascals (see the Calibration
#   guide below); in dBFS work it is the raw [-1, 1] array and the result is
#   FS^2/Hz.
fs = 48000.0                                      # its sample rate in Hz
res = signals.power_spectral_density(record, fs)          # Hann, 50 % overlap, 95 % CI
print(res.n_averages, res.random_error)           # nd and 1/sqrt(nd)
print(res.confidence_lower[10], res.psd[10], res.confidence_upper[10])
res.plot()                                        # PSD in dB with the CI band
```

The **resolution bias** is the other half of the error budget: a finite
analysis bandwidth $B_\mathrm{e}$ (reported as `resolution_bandwidth`, the effective
noise bandwidth of the taper) smooths sharp spectral features, always in the
direction of reduced dynamic range (Eq. 8.139). For a resonance peak of
half-power bandwidth $B_\mathrm{r}$, the first-order normalized bias is the closed form
of Eq. 8.141, exposed as `resolution_bias_error`:

$$
\varepsilon_\mathrm{b}[\hat{G}_{xx}(f_\mathrm{r})] \approx -\frac{1}{3}\left(\frac{B_\mathrm{e}}{B_\mathrm{r}}\right)^2 .
$$

```python
from phonometry import signals

eps_b = signals.resolution_bias_error(res.resolution_bandwidth, 25.0)  # Br = 25 Hz peak
```

Narrow $B_\mathrm{e}$ (long segments) suppresses the bias but leaves fewer averages and
a larger random error; the two requirements on segment length pull in
opposite directions, which is exactly the trade-off the reported numbers make
visible.

### Choosing the segment length, and then the record length

The bias formula is more useful read backwards. Keeping a resonance peak's bias
under 1 dB means $\varepsilon_\mathrm{b} \ge -0.2$, hence $B_\mathrm{e} \le 0.775\,B_\mathrm{r}$; keeping
it under a tenth of a decibel means $B_\mathrm{e} \le 0.263\,B_\mathrm{r}$. The familiar rule of
thumb (three or four analysis bandwidths across the half-power width of the
narrowest feature that matters) is exactly this formula, and now it has a
number attached to it.

Work forward from the measurement rather than from a habitual `nperseg`. A mode
at 100 Hz with $Q = 50$ has $B_\mathrm{r} = f/Q = 2$ Hz. Holding its bias under 2 %
(0.09 dB) needs $B_\mathrm{e} \le B_\mathrm{r}\sqrt{3 \times 0.02} = 0.49$ Hz, and for the Hann
taper $B_\mathrm{e} = 1.5\,f_\mathrm{s}/\texttt{nperseg}$, so at 48 kHz that is
`nperseg` $\ge 147\,000$, i.e. segments of at least **3.1 s**. Asking for a 10 %
random error then needs $n_\mathrm{d} = 100$ effective averages, which at 50 % overlap
means a record of about **150 s**:

```python
target_bias = 0.02                     # 2 % on the peak, about 0.09 dB
b_r, q = 100.0 / 50.0, 100             # a 100 Hz mode with Q = 50
b_e = b_r * (3 * target_bias) ** 0.5   # the analysis bandwidth it allows
nperseg = 1.5 * 48000 / b_e            # Hann: Be = 1.5 fs / nperseg
record_s = q * 0.5 * nperseg / 48000   # nd = 100 averages at 50 % overlap
print(round(b_e, 2), int(nperseg), round(record_s))     # 0.49 146969 153
```

![Left: the Welch estimate of a 25 hertz wide resonance at 1 kilohertz computed with segment lengths of 512, 1024, 4096 and 16384 samples; the short segments clip and broaden the peak while the long ones resolve it. Right: the resolution bias and the random error in decibels against segment length on a logarithmic axis, the bias falling steeply and the random error rising slowly, crossing near 7400 samples, with the measured peak deficit following the bias](https://docs.jmrp.io/phonometry/media/psd_segment_tradeoff.svg)

*The same 25 Hz-wide resonance seen at four segment lengths. At
`nperseg = 512` the analysis bandwidth is 140.6 Hz, five times the resonance
width, and the peak reads about 8 dB low and far too broad; by 4096 the
bandwidth is 17.6 Hz and the peak is essentially resolved. The right panel puts
the two errors on one axis: the bias falls as $B_\mathrm{e}^2$ and the random error rises
as $n_\mathrm{d}^{-1/2}$, and they are equal near `nperseg = 7400` for this resonance,
which is the segment length to choose if there is no reason to favour one error
over the other.*

The two decisions are independent: **the segment length is set by the sharpest
feature that matters, the record length by the precision you want.** Lengthening
the segments without lengthening the record trades one error for the other and
buys nothing. And 150 s of record is 150 s over which the process has to stay
stationary, which is a claim, not an assumption, and the one
[Data qualification](https://docs.jmrp.io/phonometry/signals/metrology/data-qualification/) decides.
When the record simply cannot be that long, the multitaper estimator of section
7 is the escape.

### From digital units to dB SPL

`power_spectral_density` scales whatever it is given and applies no calibration
of its own, so the sensitivity factor goes on the *record*, before the estimate:

```python
calibration_factor = 1.002             # Pa per digital unit, from the calibrator
pressure = calibration_factor * record
psd = signals.power_spectral_density(pressure, fs)      # now in Pa^2/Hz
```

The ordinate is then $10\log_{10}(G_{xx}/p_0^2)$ dB re (20 µPa)²/Hz, and with
`scaling="spectrum"` the same call reads a discrete tone's level directly as
$10\log_{10}(P/p_0^2)$ dB. To get from there to the band level an acoustic
report contains, integrate the density over the band, sum the bins and multiply
by the bin spacing, and divide by $p_0^2$; `fractional_octave_smoothing` in
section 4 is a display smoother and not a substitute for that integration, as
that section spells out. The factor itself comes from
[Calibration and dBFS](https://docs.jmrp.io/phonometry/signals/metrology/calibration/).

![Welch power spectral density of pink noise in dB per Hz over 20 Hz to 20 kHz, with the 95 percent chi-square confidence band shaded around the estimate, the 1/3-octave smoothed curve on top and the exact -3.01 dB per octave power law as a dashed reference line](https://docs.jmrp.io/phonometry/media/psd_confidence_smoothing.svg)

*What 20 s of record buys, read off the figure. 467 segments of 4096 samples
give 442 equivalent averages, a normalized random error of 0.047 and a 95 %
chi-square band 0.81 dB wide, so the ragged estimate is never more than about
0.8 dB from the smoothed curve anywhere in the decade, and the shaded band, not
the ripple, is the honest statement of what is known. Both curves fit
−3.007 dB/octave against the exact −3.01 dB/octave of pink noise. Smoothing
narrows nothing: it redraws the same estimate, and the interval below it still
applies.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import signals

fs = 48000.0
x = signals.noise_signal(fs, duration_s=20.0, color="pink", seed=11)
res = signals.power_spectral_density(x, fs, nperseg=4096)
band = (res.frequencies >= 20.0) & (res.frequencies <= 20000.0)
freqs = res.frequencies[band]
smooth = signals.fractional_octave_smoothing(res.psd, frequencies=res.frequencies, fraction=3.0)[band]

fig, ax = plt.subplots(figsize=(10, 6))
ax.fill_between(freqs, 10 * np.log10(res.confidence_lower[band]),
                10 * np.log10(res.confidence_upper[band]), alpha=0.3,
                label="95 % chi-square confidence interval")
ax.semilogx(freqs, 10 * np.log10(res.psd[band]), lw=1.0,
            label="Welch PSD estimate")
ax.semilogx(freqs, 10 * np.log10(smooth), lw=2.2,
            label="1/3-octave smoothed")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("PSD [dB re 1/Hz]")
ax.legend()
plt.show()
```

## 2. Cross-spectral density

`cross_spectral_density` estimates the complex $G_{xy}(f)$ between two channels
with the same Welch core, and reports the ordinary coherence
$\gamma^2_{xy} = |G_{xy}|^2/(G_{xx}\,G_{yy})$ together with the Bendat & Piersol random errors of
the magnitude and phase (Eqs. 9.33 and 9.52, with the measured coherence in
place of the unknown true value, as the book recommends for measured data):

$$
\varepsilon_\mathrm{r}[|\hat{G}_{xy}|] = \frac{1}{|\gamma_{xy}|\sqrt{n_\mathrm{d}}}, \qquad
\mathrm{s.d.}[\hat{\theta}_{xy}] =
\frac{\left(1-\gamma^2_{xy}\right)^{1/2}}{|\gamma_{xy}|\sqrt{2 n_\mathrm{d}}} .
$$

Both shrink as the coherence approaches one: a strongly coherent pair needs
far fewer averages for the same confidence. The phase is unwrapped, so its
slope against frequency is the group delay
$\tau_\mathrm{g} = -\mathrm{d}\varphi/(2\pi\,\mathrm{d}f)$; for a pure
delay path the phase is linear and that slope reads the propagation delay
directly.

```python
import numpy as np
from phonometry import signals

delay = int(0.002 * fs)                                     # a 2 ms delay path
noise = signals.noise_signal(fs, duration_s=20.0, rms=0.3, seed=9)     # uncorrelated noise
y = 0.9 * np.concatenate([np.zeros(delay), x[:-delay]]) + noise
res = signals.cross_spectral_density(x, y, fs)
print(res.magnitude_random_error[100], res.phase_standard_deviation_rad[100])  # bin 100 errors
res.plot()   # magnitude, phase with ±sigma band, coherence
```

![Two panels for the cross-spectral density of a two-sensor path with a 2 millisecond delay: the Welch magnitude estimate fluctuating around a flat level, and below it the unwrapped cross-spectrum phase falling as a straight line on a logarithmic frequency axis, lying exactly on the dashed minus two pi f tau reference with a narrow one-sigma band around it](https://docs.jmrp.io/phonometry/media/cross_spectral_density.svg)

*The cross-spectral density of a 2 ms delay path: the unwrapped phase is
exactly the line $-2\pi f\tau$, so its slope reads the propagation delay
directly,
and the ±1 s.d. band of Eq. 9.52 quantifies how far to trust it per
frequency.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import signals

fs = 8000.0
tau = 0.002                                   # 2 ms = 16 samples
delay = int(tau * fs)
x = signals.noise_signal(fs, duration_s=8.0, seed=8)
noise = signals.noise_signal(fs, duration_s=8.0, rms=0.3, seed=9)
y = 0.9 * np.concatenate([np.zeros(delay), x[:-delay]]) + noise

res = signals.cross_spectral_density(x, y, fs)

# One line — magnitude, phase with its ±sigma band and coherence:
res.plot()
plt.show()

# By hand, from the fields the result carries:
band = (res.frequencies >= 20) & (res.frequencies <= 3500)
freqs = res.frequencies[band]
fig, (ax_m, ax_p) = plt.subplots(2, 1, sharex=True)
ax_m.semilogx(freqs, 10 * np.log10(res.magnitude[band]),
              label="|Gxy| (Welch estimate)")
ax_m.set_ylabel("Magnitude [dB]")
ax_p.semilogx(freqs, res.phase_rad[band], label="Unwrapped phase")
ax_p.fill_between(freqs, res.phase_rad[band] - res.phase_standard_deviation_rad[band],
                  res.phase_rad[band] + res.phase_standard_deviation_rad[band], alpha=0.25,
                  label="±1 s.d. (Eq. 9.52)")
ax_p.semilogx(freqs, -2 * np.pi * freqs * tau, "r--",
              label="slope -2·pi·f·tau")
ax_p.set(xlabel="Frequency [Hz]", ylabel="Phase [rad]")
for ax in (ax_m, ax_p):
    ax.legend()
plt.show()
```

## 3. Coherent output spectrum and spectral SNR

In the single-input/single-output model the measured output autospectrum
splits exactly into the part linearly explained by the input and the
uncorrelated remainder (Eqs. 9.55–9.57):

$$
G_{vv} = \gamma^2_{xy}\,G_{yy}, \qquad
G_{nn} = \left(1-\gamma^2_{xy}\right) G_{yy}, \qquad
\mathrm{SNR}(f) = \frac{\gamma^2_{xy}}{1-\gamma^2_{xy}} .
$$

`coherent_output_spectrum` returns all three spectra, the spectral
signal-to-noise ratio (linear and in dB) and the random error of the coherent
output estimate (Eq. 9.73), plus the first-order propagation of the coherence
error through the SNR:

$$
\varepsilon_\mathrm{r}[\hat{G}_{vv}] =
\frac{\left(2-\gamma^2_{xy}\right)^{1/2}}{|\gamma_{xy}|\sqrt{n_\mathrm{d}}}, \qquad
\varepsilon_\mathrm{r}[\widehat{\mathrm{SNR}}] = \frac{\sqrt{2}}{|\gamma_{xy}|\sqrt{n_\mathrm{d}}} .
$$

For additive uncorrelated output noise of known level the coherence has the
closed form $\gamma^2 = \mathrm{SNR}/(1+\mathrm{SNR})$, which makes the whole chain verifiable with a
synthetic signal:

```python
import numpy as np
from phonometry import signals

fs = 48000.0
x = signals.noise_signal(fs, duration_s=8.0, color="white", seed=1)
noise = signals.noise_signal(fs, duration_s=8.0, color="white", rms=0.5, seed=2)
y = 0.8 * x + noise                      # SNR = 0.64/0.25 at every frequency

res = signals.coherent_output_spectrum(x, y, fs)
print(np.median(res.coherence))          # -> SNR/(1+SNR) = 0.719
print(np.median(res.snr_db))             # -> 10·lg(2.56) = 4.1 dB
res.plot()                               # Gyy, Gvv, Gnn and the SNR panel
```

![Two panels for the coherent output spectrum of a white noise system with additive noise: the measured output spectrum with the coherent part about 1.5 decibels below it and the uncorrelated noise floor about 6 decibels lower still, and below them the spectral signal-to-noise ratio fluctuating around the dashed closed-form line at 4.1 decibels](https://docs.jmrp.io/phonometry/media/coherent_output_snr.svg)

*The exact split of the snippet's model: $G_{vv} = \gamma^2 G_{yy}$ explains the output
except for the flat noise remainder $G_{nn}$, and the spectral SNR scatters
around its closed form $10\log_{10}(0.64/0.25) = 4.1$ dB at every frequency.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import signals

fs = 48000.0
x = signals.noise_signal(fs, duration_s=8.0, color="white", seed=1)
noise = signals.noise_signal(fs, duration_s=8.0, color="white", rms=0.5, seed=2)
y = 0.8 * x + noise                      # SNR = 0.64/0.25 per band

res = signals.coherent_output_spectrum(x, y, fs, nperseg=2048)

# One line — the three spectra and the SNR panel:
res.plot()
plt.show()

# By hand, from the fields the result carries:
band = (res.frequencies >= 20) & (res.frequencies <= 20000)
freqs = res.frequencies[band]
fig, (ax_g, ax_s) = plt.subplots(2, 1, sharex=True)
for values, style, label in ((res.output_psd, "-", "Gyy (measured)"),
                             (res.coherent_psd, "--", "Gvv (coherent)"),
                             (res.noise_psd, ":", "Gnn (noise)")):
    ax_g.semilogx(freqs, 10 * np.log10(values[band]), style, label=label)
ax_g.set_ylabel("Spectral density [dB re 1/Hz]")
ax_s.semilogx(freqs, res.snr_db[band], label="Spectral SNR [dB]")
ax_s.axhline(10 * np.log10(0.64 / 0.25), color="r", linestyle="--",
             label="closed form 4.1 dB")
ax_s.set(xlabel="Frequency [Hz]", ylabel="SNR [dB]")
for ax in (ax_g, ax_s):
    ax.legend()
plt.show()
```

The `coherence_bias` field reports the small positive bias of the coherence
estimate, $b[\hat{\gamma}^2] \approx (1-\gamma^2)^2/n_\mathrm{d}$ (Eq. 9.75),
negligible once $n_\mathrm{d}$ reaches a
few hundred, and another reason to average generously before trusting a low
coherence.

## Two channels in practice

Sections 2 and 3 both start from a pair of records, and everything they report
is only as good as the pair. Two halves: how to acquire it, and how to read a
coherence that comes back below one.

**Acquisition.** Use one interface with *simultaneously sampled* inputs, or
measure the inter-channel skew and remove it. A converter that sequences its
channels puts a fixed skew straight into the cross-spectrum phase and therefore
into every group delay read off it: one sample of skew at 48 kHz is 20.8 µs,
which is 15° of phase at 2 kHz and a flat 20.8 µs error on any delay estimate.
Set both gains before the run and do not touch them, because the coherent output
split of section 3 assumes the two channels share a fixed scale. Validate the
pair once with a **zero-baseline run**: feed both channels the same signal (the
generator split into both inputs, or the two microphones side by side) and
confirm that the measured delay is a small fraction of a sample and the
coherence is unity across the band. That one run separates a chain problem from
a physics problem for every measurement afterwards.

**Reading a coherence below one.** It is not automatically an SNR problem, and
Bendat & Piersol name five causes with different fixes:

| What you see | The cause | The fix |
| :--- | :--- | :--- |
| Coherence flat across the band, consistent with $\gamma^2 = \mathrm{SNR}/(1+\mathrm{SNR})$ | uncorrelated noise at either sensor (the modelled case of section 3) | average more, raise the level, get closer |
| Coherence falling progressively with frequency, worse as the record is segmented shorter | a bulk propagation delay comparable with the segment length | align the records first, or raise `nperseg` well above the delay; see [Correlation and delay](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/) |
| Sharp dips exactly at the resonances | resolution bias: the analysis bandwidth smears the peak differently in the two channels | lengthen the segment; the $\varepsilon_\mathrm{b}$ formula of section 1 says by how much |
| Low at the harmonics of a strong tone while broadband coherence stays high | non-linearity, a rattle or a clipped channel | fix the path, or work below the level at which it appears |
| Low over a band with no obvious structure | a second, uncorrelated source is also driving the output | the [MISO page](https://docs.jmrp.io/phonometry/signals/spectra/miso-coherence/): one input cannot explain two sources |

Two closing cautions. The coherence estimate is biased **high** by
$(1-\gamma^2)^2/n_\mathrm{d}$, so a low coherence read from a handful of averages is even
lower than it looks. And read the other way, a coherence near one *is* the
acceptance criterion that makes the whole estimate reportable: quote it band by
band beside the transfer function, because the bands where it falls are exactly
the bands where the numbers above it mean nothing.

## 4. Fractional-octave smoothing

`fractional_octave_smoothing` averages a spectrum over a rectangular window
of constant relative width: 1/n octave, $[f\cdot 2^{-1/2n},\ f\cdot 2^{+1/2n}]$
around each frequency. This is the constant-percentage resolution bandwidth that
Bendat & Piersol recommend for the spectra of resonant systems
(Section 8.5.3), and the de facto standard for presenting loudspeaker and
room responses. The average is always computed on **power** (amplitudes are
squared first, dB levels converted and back), so band power is conserved
rather than amplitude, and a flat spectrum passes through exactly unchanged.

The three `domain=` values name what the ordinate you hand it *is*, because the
averaging is always done on power and the conversion back has to know where it
started: a density or a power spectrum (`"power"`, the default), a linear
magnitude such as a frequency-response $|H|$ (`"amplitude"`, squared first), or
a curve already in decibels (`"db"`, converted and converted back).

```python
import numpy as np
from phonometry import signals

res = signals.power_spectral_density(record, fs)   # the section 1 estimate
freqs = res.frequencies
smooth_psd = signals.fractional_octave_smoothing(res.psd, frequencies=freqs, fraction=3.0)
magnitude = np.sqrt(res.psd)               # any linear |H| would do here
smooth_mag = signals.fractional_octave_smoothing(magnitude, frequencies=freqs, fraction=6.0,
                                                 domain="amplitude")  # an FRF |H|
levels = 10.0 * np.log10(res.psd)          # any dB curve would do here
smooth_db = signals.fractional_octave_smoothing(levels, frequencies=freqs, fraction=3.0, domain="db")
```

A single spectral line with PSD ordinate $P$ (units²/Hz) in a bin of width
$\Delta f$ smooths to the closed-form level
$P\,\Delta f / (f_0(2^{1/2n} - 2^{-1/2n}))$
over one kernel width, the oracle pinned in the tests.

### A smoothed density is still a density

Smoothing changes the *resolution* of the estimate, never its units. The output
of `fractional_octave_smoothing` is a density in units²/Hz, exactly as the input
was; flat white noise smooths to the same flat density, whereas the
one-third-octave **band levels** of that same white noise rise 3 dB per band.
Overlay a smoothed PSD on a filter-bank spectrum without converting and the two
disagree by 20 to 30 dB, and neither is wrong.

The conversion is one term. A fractional-octave band of centre frequency $f_\mathrm{c}$
has bandwidth $B_n = f_\mathrm{c}\,(2^{1/2n} - 2^{-1/2n})$, that is $0.2316\,f_\mathrm{c}$ in one
third of an octave and $0.7071\,f_\mathrm{c}$ in a full octave, so

$$
L_\text{band} = 10\log_{10}\!\left(\frac{G(f_\mathrm{c})\,B_n}{p_0^2}\right),
$$

which at 1 kHz in one-third octave adds $10\log_{10}(0.2316 \times 1000) =
23.65$ dB to the density level, and 3 dB more for every octave upward. Summing
the PSD bins across the band and multiplying by the bin spacing is the exact
form; the expression above is its flat-within-the-band approximation.

Which presentation belongs where: the **smoothed density** for comparing
loudspeaker and room magnitude responses, where the eye wants a curve at
constant relative resolution; the **band level** for anything that faces a
criterion, or that has to agree with `octave_filter` and `OctaveFilterBank`:
see [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/).

## 5. Colored-noise generators

`noise_signal` produces Gaussian noise whose PSD follows
$G_{xx}(f) \propto f^\alpha$ exactly in expectation: seeded white noise is
shaped in the frequency domain by the exact magnitude response
$(f/f_\text{ref})^{\alpha/2}$ bin by bin (a zero-phase filter applied
circularly), so a measured slope deviates from the power law
only by the random error of the spectral estimate, not by the piecewise or
few-pole pink approximations whose slope ripples by fractions of a dB. The
record is zero-mean and rescaled to the requested RMS exactly, and the same
seed reproduces the same record bit for bit.

| color | $\alpha$ | PSD slope |
|---|---|---|
| `white` | 0 | 0 dB/octave |
| `pink` | -1 | -3.01 dB/octave |
| `red` (Brownian) | -2 | -6.02 dB/octave |
| `blue` | +1 | +3.01 dB/octave |
| `violet` | +2 | +6.02 dB/octave |

```python
from phonometry import signals

pink = signals.noise_signal(48000, duration_s=10.0, color="pink", seed=7)     # deterministic
white = signals.noise_signal(48000, duration_s=10.0, color="white", rms=0.5, seed=7)
```

Measured over three decades (20 Hz – 20 kHz) with the estimator of section 1,
the regression slope of each color lands within a few thousandths of a
dB/octave of the exact value; the conformance suite pins the pink slope at
-3.0116 against the exact -3.0103.

Those slopes are density slopes, and they are not what a fractional-octave
display of the same signal shows. A band's width grows in proportion to its
centre frequency, so a band level is the density plus $10\log_{10} B_n$ with
$B_n \propto f_\mathrm{c}$: **every colour reads 3 dB per octave higher in a band display
than its density slope suggests.** White noise, whose density is flat, therefore
rises 3 dB per octave through an octave-band filter bank, and pink noise, at
−3 dB/octave, comes out flat, which is why pink is the reference stimulus for
room and loudspeaker work, and why an octave-band spectrum of white noise
sloping upward is not a bug. Red noise falls 3 dB per octave in a band display
and blue rises 6. The same +3 dB per octave applies to any density-versus-band
comparison in this library; section 4 above gives the exact conversion, and
[Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) is where the band side lives.

![Welch spectral densities of the five noise colours over 20 hertz to 20 kilohertz, each normalised to its own 1 kilohertz level so the five straight lines fan out from a single point: violet rising at 6 dB per octave, blue at 3, white flat, pink falling at 3 and red at 6, each with its exact power law dashed underneath and the measured regression slope in the legend](https://docs.jmrp.io/phonometry/media/noise_colors.svg)

*The five generators over three decades, each normalised to its own 1 kHz level
so the slopes fan out from one point, with the exact power law dashed
underneath. The measured regression slopes land within four thousandths of a
decibel per octave of the exact values, and the residual is the random error of
the *estimator*, not of the generator: the same seed reproduces the record bit
for bit.*

## 6. Choosing the window

Every estimator on this page accepts any window
`scipy.signal.get_window` knows, but the choice is a quantified
trade-off, not a preference. `window_metrics` computes the figures of merit
Harris (1978) tabulated, for any taper and length, sampled DFT-even exactly
as the Welch estimators apply it:

- **ENBW** (equivalent noise bandwidth, in bins): how much wider than one
  bin the effective analysis bandwidth is. This is the same number the PSD
  result reports as `resolution_bandwidth` (`ENBW·fs/nperseg` in Hz), and
  it enters directly in the tone/noise trade: a broadband noise floor read
  from a windowed spectrum sits $10\log_{10}(\mathrm{ENBW})$ dB above the true
  density.
- **Coherent gain**: the DC gain $\sum w/N$ a bin-centered tone is scaled by.
- **Scalloping loss**: the worst-case attenuation of a tone that falls
  midway between two bins (3.92 dB for rectangular, 1.42 dB for Hann).
- **Worst-case processing loss**: scalloping plus $10\log_{10}(\mathrm{ENBW})$, the
  worst-case reduction in output SNR for tone detection in white noise.
- **Highest sidelobe** and **main-lobe -3 dB width**: leakage floor versus
  resolution.

```python
from phonometry import signals

m = signals.window_metrics("hann", 2048)
print(m.enbw_bins)              # 1.5, exactly
print(m.scalloping_loss)     # 1.42 dB
print(m.highest_sidelobe_level)    # -31.5 dB
m.plot()                        # window + spectrum with metrics marked
```

The closed forms anchor the tests: ENBW is exactly 1 for rectangular, 3/2
for Hann, 1987/1458 for Hamming and 1523/882 for Blackman (DFT-even
sampling), and the rectangular scalloping loss is $20\log_{10}(N\sin(\pi/2N))$,
the Dirichlet kernel evaluated half a bin off center.

![Spectra of the rectangular, Hann, Hamming and Blackman windows over 16 DFT bins, showing the trade-off between main-lobe width and sidelobe level, with each window's equivalent noise bandwidth and highest sidelobe level in the legend](https://docs.jmrp.io/phonometry/media/window_functions_tradeoff.svg)

*The trade in one picture, and it costs 44.8 dB of leakage floor to buy 0.73 of
a bin. Going from rectangular to Blackman drops the highest sidelobe from
−13.3 dB to −58.1 dB while the ENBW widens from 1.000 to 1.727 bins and the
−3 dB main lobe from 0.886 to 1.644 bins. Hann sits where the module's default
sits: −31.5 dB for 1.500 bins. Read the two axes together, a narrow main lobe
separates two tones of similar level, a low sidelobe floor finds a weak tone
beside a strong one, and no window does both.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import signals

n, oversample = 1024, 256
fig, ax = plt.subplots(figsize=(10, 6.2))
for name in ("boxcar", "hann", "hamming", "blackman"):
    res = signals.window_metrics(name, n)
    spectrum = np.abs(np.fft.rfft(res.taps, n=n * oversample))
    level = 20.0 * np.log10(spectrum / spectrum[0])
    bins = np.arange(level.size) / oversample
    shown = bins <= 16.0
    ax.plot(bins[shown], level[shown],
            label=(f"{name}: ENBW {res.enbw_bins:.2f} bins, "
                   f"sidelobe {res.highest_sidelobe_level:.1f} dB"))
ax.set_xlim(0.0, 16.0)
ax.set_ylim(-100.0, 5.0)
ax.set_xlabel("Frequency offset [DFT bins]")
ax.set_ylabel("Level re main lobe [dB]")
ax.legend(loc="upper right")
plt.tight_layout()
plt.show()
```

The Hann default of this module is the balanced choice: fast sidelobe
falloff (-18 dB/octave) protects noise spectra from leakage, ENBW 1.5 costs
only 1.76 dB against the rectangular window, and its overlap correlation at
50 % keeps nearly all segment information in the effective average count.
Reach for a lower-sidelobe taper (Blackman, Kaiser with a high beta) when a
weak tone must be found next to a strong one, and accept the wider main
lobe; reach for the rectangular window only for self-windowing records
(transients that decay inside the segment) or bin-centered synthesis.

## 7. Multitaper estimation for short records

Welch's method buys stability with record length: each independent segment
adds two degrees of freedom, so a record that only fits a couple of segments
leaves an estimate barely better than a periodogram. `multitaper_psd`
implements the alternative of Thomson (1982), as developed by Percival &
Walden (1993, Chapter 7): the *whole* record is multiplied by $K$ orthogonal
discrete prolate spheroidal (Slepian) tapers - the sequences that concentrate
the most spectral-window energy inside a chosen design band $[-W, W]$ - and
the $K$ resulting *eigenspectra* are averaged:

$$
\hat{S}^{(mt)}(f) = \frac{1}{K}\sum_{k=0}^{K-1} \hat{S}_k(f), \qquad
\hat{S}_k(f) = \Delta t\,\Bigl|\sum_{t=1}^{N} h_{t,k}\,x_t\,
\mathrm{e}^{-i 2\pi f t \Delta t}\Bigr|^2 .
$$

Because the tapers are orthogonal the eigenspectra are nearly uncorrelated,
so the average carries about $2K$ chi-square degrees of freedom from a
single record - the same statistical machinery as the Welch result (random
error, chi-square confidence interval), without segmenting. The
design parameter is the dimensionless duration-times-half-bandwidth product
$p = NW$ (default 4), and for a record of $N_\mathrm{r}$ samples at $f_\mathrm{s}$ it fixes the
half-bandwidth $W = p\,f_\mathrm{s}/N_\mathrm{r}$ in hertz. $2W$ is the resolution of the estimate
(reported as `resolution_bandwidth`), and only the tapers below the Shannon
number $2p$ keep their spectral-window energy inside the design band - their
concentrations $\lambda_k$ are reported as `eigenvalues`, and the default
taper count is $K = 2p - 1$, all tapers with near-unity concentration.
Larger $p$ admits more tapers (lower variance) at the cost of resolution.

```python
from phonometry import signals

res = signals.multitaper_psd(record, fs)                 # p = NW = 4, K = 7, adaptive
print(res.degrees_of_freedom.mean())             # ~2K from one record
print(res.eigenvalues)                           # taper concentrations
res.plot()                                       # density with the CI band
```

By default the eigenspectra are combined with Thomson's **adaptive weights**
(P&W Eqs. 368a/370a, iterated to convergence). Each taper's weight at each
frequency balances the local spectrum against the broad-band leakage the
taper could carry:

$$
b_k(f) = \frac{S(f)}{\lambda_k S(f) + (1-\lambda_k)\,\sigma^2 \Delta t},
\qquad
\hat{S}^{(amt)}(f) =
\frac{\sum_k b_k^2(f)\,\lambda_k\,\hat{S}_k(f)}
     {\sum_k b_k^2(f)\,\lambda_k},
$$

so the leakier high-order tapers are downweighted exactly where the spectrum
is locally weak, and nothing is lost where it is locally white (for white
noise the weights are uniform). The price is bookkept honestly: the
equivalent degrees of freedom become frequency dependent,
$\nu(f) = 2\left(\sum_k d_k\right)^2/\sum_k d_k^2$ with
$d_k = b_k^2\lambda_k$ (P&W Eq. 370b), and the
confidence interval widens wherever leakage protection spent them.
`adaptive=False` selects the plain eigenvalue-weighted average instead.

Calibration matches the Welch estimators exactly: no detrending,
`'density'` integrates to the signal power, and `'spectrum'` reads $A^2/2$ at
the peak of a sinusoid of amplitude $A$ (a tone's power in `'density'`
scaling spreads over the $2W$ band). The Slepian tapers themselves come from
`scipy.signal.windows.dpss`; their concentrations reproduce the
quadruple-precision table of Percival & Walden (Table 382) to machine
precision, which is the anchor oracle of the test suite.

![Left: the multitaper spectral density of a 171 millisecond pink noise record with its 95 percent confidence band, against a Welch estimate with only 6.7 effective averages and a visibly wider band, a single-taper estimate as a jagged grey line and the exact minus 3.01 dB per octave law dashed. Right: a 60 dB tone over a pink floor, where the Hann-windowed Welch estimate leaves a wider skirt around the tone than the adaptive multitaper, and the equivalent degrees of freedom drop from about nine to five where the adaptive weights spend them](https://docs.jmrp.io/phonometry/media/multitaper_psd_confidence.svg)

*Left, the case the text claims multitaper wins: a 171 ms record. Welch with a
2048-sample segment fits only $n_\mathrm{d} = 6.7$ effective averages into it, so its
confidence band is visibly the wider of the two and its curve the rougher, while
the 7-taper adaptive estimate carries 13.7 equivalent degrees of freedom from
the same record. Right, the other reason to reach for it: a 60 dB tone over a
pink floor. The Hann taper leaves a broader skirt around the tone than the
adaptive weights do, and the price is printed on the right-hand axis, the
equivalent degrees of freedom fall wherever the weights bought that protection,
which is exactly what widens the confidence interval there.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import signals

fs = 48000.0
x = signals.noise_signal(fs, duration_s=8192 / fs, color="pink", seed=11)   # 171 ms record
single = signals.multitaper_psd(x, fs, n_tapers=1, adaptive=False)
res = signals.multitaper_psd(x, fs)                              # NW = 4, K = 7
band = (res.frequencies >= 20.0) & (res.frequencies <= 20000.0)
freqs = res.frequencies[band]

fig, ax = plt.subplots(figsize=(10, 6))
ax.semilogx(freqs, 10 * np.log10(single.psd[band]), color="gray",
            alpha=0.45, lw=0.7, label="Single Slepian taper (K = 1)")
ax.fill_between(freqs, 10 * np.log10(res.confidence_lower[band]),
                10 * np.log10(res.confidence_upper[band]), alpha=0.3,
                label="95 % chi-square confidence interval")
ax.semilogx(freqs, 10 * np.log10(res.psd[band]), lw=1.2,
            label="Multitaper estimate (K = 7, adaptive)")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("PSD [dB re 1/Hz]")
ax.legend()
plt.show()
```

Reach for `multitaper_psd` when the record is too short to segment (room
impulse response tails, transient captures, single machine cycles) or when
a high-dynamic-range spectrum needs leakage protection that a Hann-windowed
Welch average cannot give; stay with `power_spectral_density` for long
records, where segment averaging is cheaper than $K$ full-length FFTs and
the two estimators agree.

## Consistency with the frequency-response and intensity estimators

The [frequency-response estimators](https://docs.jmrp.io/phonometry/devices/electroacoustics/electroacoustics/)
form the same cross-spectra into transfer functions: $H_1 = G_{xy}/G_{xx}$,
unbiased when the noise is on the output, and $H_2 = G_{yy}/G_{yx}$, unbiased
when it is on the input. The two-microphone
[sound intensity](https://docs.jmrp.io/phonometry/devices/emission/intensity/) probe forms the
imaginary part of $G_{xy}$. Those estimators,
`transfer_function` and `coherence`, the intensity probe and these estimators
all share one Welch core (same taper, overlap policy and detrend-off
calibration), so a PSD, a coherence and an $H_1$ computed with the same segment
length are mutually consistent bin by bin. The same cross-spectral matrix
underlies [multiple and partial coherence](https://docs.jmrp.io/phonometry/signals/spectra/miso-coherence/),
which extends the ordinary coherence to several correlated inputs and one
output.

## What this guide covers

- **Covered.** Bendat & Piersol's Welch estimators (*Random Data*, 4th ed., 2010, Sections
  5.2, 8.5, 9.1-9.2 and 11.5): `power_spectral_density` and
  `cross_spectral_density` with the effective number of averages, chi-square
  confidence intervals and the resolution-bias error; the coherent output
  spectrum and spectral SNR; the Harris (1978) window figures of merit of
  `window_metrics`; and the Thomson (1982) multitaper estimator of
  `multitaper_psd`, following Percival & Walden's Chapters 7-8.
  `fractional_octave_smoothing` and `noise_signal` complete the toolbox.

- **Not covered.** The frequency-response estimators `transfer_function` and `coherence`, and the
  sound-intensity probe, share this page's Welch core but are documented on the
  [electroacoustics](https://docs.jmrp.io/phonometry/devices/electroacoustics/electroacoustics/) and
  [sound intensity](https://docs.jmrp.io/phonometry/devices/emission/intensity/) pages, not here. So
  is multiple and partial coherence, on the [MISO
  coherence](https://docs.jmrp.io/phonometry/signals/spectra/miso-coherence/) page. This page
  implements Bendat & Piersol's textbook estimators, not a certification
  standard, so it carries no clause numbers or compliance limits to check
  against.

## See also

- [Data qualification](https://docs.jmrp.io/phonometry/signals/metrology/data-qualification/): the stationarity every chi-square interval on this page assumes.
- [Calibration and dBFS](https://docs.jmrp.io/phonometry/signals/metrology/calibration/): where the factor that turns this page's densities into Pa²/Hz comes from.
- [MISO coherence](https://docs.jmrp.io/phonometry/signals/spectra/miso-coherence/): the same cross-spectral matrix with several correlated inputs.
- [Time-frequency analysis](https://docs.jmrp.io/phonometry/signals/spectra/time-frequency/): the same Welch segmentation displayed instead of averaged.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): the band-level side of the density/band conversion of section 4.
- API reference: [`signals.spectra`](https://docs.jmrp.io/phonometry/reference/api/signals/spectra/), [`signals.windows`](https://docs.jmrp.io/phonometry/reference/api/signals/windows/) and [`signals.multitaper`](https://docs.jmrp.io/phonometry/reference/api/signals/multitaper/).
- Theory: [Frequency Resolution vs FFT Bin Spacing](https://docs.jmrp.io/phonometry/reference/theory/signal-analysis/#frequency-resolution-vs-fft-bin-spacing): why the bin spacing of an FFT is not the resolution of the estimate, and what the window does to both.

## References

- **Bendat, J. S., & Piersol, A. G. (2010).** *Random data: Analysis and measurement procedures* (4th ed.). Wiley. https://doi.org/10.1002/9781118032428
  Sections 5.2 and 8.5 (autospectra and their random/bias errors, chi-square intervals), 9.1-9.2 (cross-spectra, coherent output spectrum and their errors) and 11.5 (Welch processing, tapering and overlap). ISBN 978-0-470-24877-5.
- **Harris, F. J. (1978).** On the use of windows for harmonic analysis with the discrete Fourier transform. *Proceedings of the IEEE*, *66*(1), 51-83. https://doi.org/10.1109/PROC.1978.10837
  The window figures of merit (Table 1): equivalent noise bandwidth, coherent gain, scalloping loss, worst-case processing loss, highest sidelobe level and main-lobe width, computed by window_metrics for any scipy taper.
- **Percival, D. B., & Walden, A. T. (1993).** *Spectral analysis for physical applications: Multitaper and conventional univariate techniques*. Cambridge University Press. https://doi.org/10.1017/CBO9780511622762
  Chapter 7 (multitaper estimation: eigenspectra, adaptive weighting, equivalent degrees of freedom) and Chapter 8 (computing the Slepian sequences); the Table 382 eigenvalues anchor the taper oracle in the test suite. ISBN 978-0-521-43541-3.
- **Thomson, D. J. (1982).** Spectrum estimation and harmonic analysis. *Proceedings of the IEEE*, *70*(9), 1055-1096. https://doi.org/10.1109/PROC.1982.12433
  The multitaper method: Slepian tapers, eigenspectra and the adaptive weights implemented by multitaper_psd.
- **Welch, P. D. (1967).** The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. *IEEE Transactions on Audio and Electroacoustics*, *15*(2), 70-73. https://doi.org/10.1109/TAU.1967.1161901
  The overlapped-segment variance formula behind the effective number of averages (Bendat & Piersol Section 11.5.2.2, Ref. 11).