# Data qualification: stationarity and peaks

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/signals/metrology/data-qualification/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/signals/metrology/data-qualification/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-21
Updated: 2026-11-11T17:49:27Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Qualification of a random record before analysis: Bendat & Piersol stationarity (reverse arrangements, runs) and Rice peak statistics.

---

Every average in this documentation - a [PSD](https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/), a
[Leq](https://docs.jmrp.io/phonometry/signals/levels/levels/), a
[GUM budget](https://docs.jmrp.io/phonometry/signals/metrology/gum-uncertainty/) - assumes the record is
**stationary**: that the process generating it did not drift while it was
being measured. Bendat & Piersol devote Section 10.3 of *Random Data* to
qualifying records before analysis, and `phonometry.metrology` implements its
quantitative core: distribution-free **trend and stationarity tests** with
the book's own acceptance regions, and the **Rice statistics** - level
crossings, apparent frequency, peak rates and heights - that summarize what
a qualified Gaussian record looks like and flag one that is not.

Qualification is a decision, not a statistic, so it reads best as a flow:
segment the record, count reverse arrangements, and let the Table A.6 region
say whether averaging is allowed.

![Decision flow diagram of data qualification: a time record, before trusting any PSD, Leq or GUM average, is split into 20 equal segments whose mean square values form a sequence, the reverse arrangement count A with trend-free mean 95 is compared against the Table A.6 acceptance region, above 64 and at most 125, at the 5 percent level, and the diamond branches to a green stationary box, steady noise with A equal to 91 accepted so the chi-square intervals and error formulas hold, or to a red nonstationary box, a 20 percent gain ramp with A equal to 7 rejected, advising to split at the change or move to short-time analysis; footnotes name the runs test companion and the mean-square blind spot for frequency glides](https://docs.jmrp.io/phonometry/media/diagram_data_qualification.svg)

## 0. Before the tests: validating the record

Bendat & Piersol's Section 10.3 covers three activities and this module
implements one of them. *Qualification*, the tests below, asks whether a
record is stationary. *Validation* asks whether it is a record of the thing at
all, and it comes first, because every defect in the list below either fails the
stationarity test for the wrong reason or, worse, passes it. Validation stays
manual, as the book describes it, but it is six lines of numpy and a decision
each:

```python
import numpy as np

rng = np.random.default_rng(0)
x = 0.15 * rng.standard_normal(1 << 16)   # your record, in digital units

full_scale = 1.0                          # 1.0 for float audio, 32768 for int16
clipped = int(np.count_nonzero(np.abs(x) >= 0.999 * full_scale))
dead = int(np.max(np.diff(np.flatnonzero(np.diff(x) != 0.0), prepend=0)))
offset = float(np.mean(x) / np.std(x))
spikes = int(np.count_nonzero(np.abs(x - np.mean(x)) > 5 * np.std(x)))
kurtosis = float(np.mean((x - np.mean(x)) ** 4) / np.std(x) ** 4)
print(clipped, dead, round(offset, 4), spikes, round(kurtosis, 2))
```

| Defect | The check | The decision |
| :--- | :--- | :--- |
| Clipping | samples at or above 0.999 of full scale | more than a handful and the record is edited or rejected: clipping deflates the high-level crossings of section 4 and inflates every mean square |
| Dropouts, dead channel | the longest run of identical consecutive samples | any run longer than a few milliseconds is a transmission fault, not a signal |
| DC offset, infrasonic drift | the record mean against its standard deviation, and the sub-20 Hz share of the PSD against the band of interest | remove the mean and high-pass before section 4, whose formulas assume a zero-mean process |
| Spikes, transient contamination | samples beyond 5σ, or a kurtosis far above 3 on a supposedly Gaussian record | edit them out and say so, or qualify the record in pieces |
| Mains hum | peaks at 50 or 60 Hz and their harmonics in a [Welch PSD](https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/) | a fault in the chain, not in the source; fix the grounding rather than the data |

The synthetic record above prints `0 1 0.0024 0 3.02`, which is what clean looks
like: no clipped samples, no repeated sample, an offset of 0.002σ, not one
excursion beyond 5σ in 65 536 Gaussian samples, and a kurtosis of 3.0 as a
Gaussian record must have.

Alongside the numbers, the acquisition metadata has to travel with the file or
none of this is reconstructible later: sample rate, bit depth, gain setting,
the [calibration factor](https://docs.jmrp.io/phonometry/signals/metrology/calibration/) and the take
it came from, microphone and windscreen, and (outdoors) wind speed and
temperature. The rule is simply that validation precedes qualification: edit or
reject first, then test for stationarity.

## 1. The reverse arrangement test

Given a sequence of $N$ observations $x_1, \dots, x_N$ - parameter estimates,
segment levels, anything - count the pairs $i < j$ with $x_i > x_j$. Each
such pair is a **reverse arrangement**, and for independent observations of
one random variable their total $A$ has (B&P Eqs. (4.54)-(4.55))

$$
\mu_A = \frac{N(N-1)}{4}, \qquad
\sigma_A^2 = \frac{N(2N+5)(N-1)}{72},
$$

with no assumption about the distribution of the $x_i$. A monotonic trend
pushes $A$ to an extreme (0 for a rising sequence, $N(N-1)/2$ for a falling
one), so the hypothesis of *no trend* is accepted at significance $\alpha$
when $A$ falls inside a two-sided region - B&P Table A.6, whose
$\alpha = 0.05$ rows `trend_test` reproduces exactly and the conformance
suite pins. The book's Example 4.4 (twenty observations, $A = 86$, accepted in
$(64, 125]$) runs verbatim:

```python
from phonometry import metrology

values = [5.2, 6.2, 3.7, 6.4, 3.9, 4.0, 3.9, 5.3, 4.0, 4.6,
          5.9, 6.5, 4.3, 5.7, 3.1, 5.6, 5.2, 3.9, 6.2, 5.0]

res = metrology.trend_test(values)                  # B&P Example 4.4
print(res.statistic, res.bounds)          # 86, (64, 125] — half-open
print(res.trend_free, round(res.p_value, 3))   # True, 0.586
res.plot()
```

![Two sequences of twenty observations plotted against the sample index: Bendat and Piersol Example 4.4, which fluctuates around five with eighty-six reverse arrangements and is accepted as trend free, and the same fluctuations with an added rising drift climbing from about five to nine, whose thirty-eight reverse arrangements fall below the lower acceptance bound of sixty-four and are rejected as trended at the five percent level](https://docs.jmrp.io/phonometry/media/trend_test.svg)

*The test never looks at the fitted slope, only at the order of the values. On
the left, Bendat & Piersol's own Example 4.4: $A = 86$, comfortably inside the
$(64, 125]$ acceptance region, $p = 0.586$. On the right, the same twenty
fluctuations with a drift added that carries them from 5.2 to 9.0: the
fluctuations are unchanged, but the ordering is not, and $A$ falls to 38, below
the lower bound, at $p = 0.0001$. A monotonic drift is what pushes $A$ towards
zero, which is why the counting works without knowing the distribution.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import metrology

example = np.array([5.2, 6.2, 3.7, 6.4, 3.9, 4.0, 3.9, 5.3, 4.0, 4.6,
                    5.9, 6.5, 4.3, 5.7, 3.1, 5.6, 5.2, 3.9, 6.2, 5.0])
drifting = example + np.linspace(0.0, 4.0, example.size)   # rising drift

res_flat = metrology.trend_test(example)
res_drift = metrology.trend_test(drifting)

fig, ax = plt.subplots(figsize=(10, 6))
index = np.arange(1, example.size + 1)
ax.plot(index, res_flat.values, "o-",
        label=f"Example 4.4: A = {res_flat.statistic}, accepted")
ax.plot(index, res_drift.values, "s-",
        label=f"Rising drift: A = {res_drift.statistic}, rejected")
ax.set_xlabel("Sample index")
ax.set_ylabel("Sequence value")
ax.legend()
plt.show()
```

`bounds` is **half-open**: the hypothesis of no trend is accepted when
`lower < A <= upper`, so $A = 125$ passes and $A = 64$ does not. The runs test
of section 3 uses the same convention, and so does the stationarity verdict of
section 2.

The p-value comes from the exact null distribution of $A$ (the inversion
counts of a random permutation), computed up to $N = 100$ - the range of
Table A.6 - and from the book's normal approximation beyond; the verdict
follows the book's tabulated region. `.plot()` draws the tested sequence
against its sample index with the count, the acceptance region and the
verdict in the legend (for `method="runs"` it also marks the sequence
median that classifies each value).

**How to read the verdict.** It is a hypothesis test, not a measurement.
`trend_free = True` means the data give *no evidence* of a trend at the chosen
level, which is a much weaker statement than "the record is stationary";
$p = 0.586$ says the observed count is entirely ordinary for a trend-free
sequence, and a $p$ just above 0.05 says almost nothing either way. The
consequence that bites in practice is multiplicity: at $\alpha = 0.05$ one
stationary record in twenty is rejected by construction, so screening the 31
one-third-octave bands of a perfectly stationary record produces one or two
rejections as the *expected* outcome. A single failing band is therefore not
evidence of anything; a run of adjacent failing bands, or a failure of the
broadband record, is. `alpha=` is the knob: tighten it when many bands are
screened, loosen it when one record must be qualified conservatively. The
acceptance bounds move with it, because they come from the exact null
distribution rather than from a table lookup.

## 2. Stationarity of a record

The B&P Sec. 10.3.1.1 procedure turns the trend test into a stationarity
test for a single time history: divide the record into $N$ equal intervals
long enough to be independent, compute a **mean square value per interval**,
and test that sequence. Nothing needs to be known about the record's
bandwidth, averaging distribution or units, and the test works on mean
values, rms values or variances just as well (`statistic=`). A running
20 % gain drift - the book's Example 10.3 scenario - is caught immediately,
while the same noise without the drift passes:

```python
import numpy as np
from phonometry import metrology

fs = 8192.0
n = 1 << 16
noise = np.random.default_rng(42).standard_normal(n)

res = metrology.stationarity_test(noise, fs)        # 20 segments, mean squares
print(res.stationary, res.trend_statistic, res.bounds)   # True, 91, (64, 125)

drifting = noise * np.linspace(1.0, 1.2, n)    # +20 % gain ramp
res = metrology.stationarity_test(drifting, fs)
print(res.stationary, res.trend_statistic)          # False, 7  (upward trend -> low A)
res.plot()
```

![Twenty segment mean square values for two noise records: a steady record whose values fluctuate around one with a reverse arrangement count of ninety-one, accepted as stationary, and the same noise with a twenty percent gain ramp whose segment mean squares climb steadily to one point five, giving only seven reverse arrangements, rejected as nonstationary at the five percent level](https://docs.jmrp.io/phonometry/media/stationarity_test.svg)

*The same twenty-segment sequence tells a stationarity story with the same
arithmetic. The steady record's segment mean squares stay between 0.982 and
1.034 and give $A = 91$, inside $(64, 125]$. The 20 % gain ramp lifts them from
1.016 to 1.476 (a change of a factor 1.45, which no eye would call dramatic on
a time trace) and $A$ collapses to 7. Twenty numbers and a pair counted
against a table are enough; nothing about the record's bandwidth or units
enters.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import metrology

fs = 8192.0
n = 1 << 16
steady = np.random.default_rng(42).standard_normal(n)
ramp = np.random.default_rng(42).standard_normal(n) * np.linspace(1.0, 1.2, n)

res_steady = metrology.stationarity_test(steady, fs)
res_ramp = metrology.stationarity_test(ramp, fs)

fig, ax = plt.subplots(figsize=(10, 6))
index = np.arange(1, res_steady.n_segments + 1)
ax.plot(index, res_steady.segment_values, "o-",
        label=f"Steady noise: A = {res_steady.trend_statistic}, accepted")
ax.plot(index, res_ramp.segment_values, "s-",
        label=f"+20 % gain ramp: A = {res_ramp.trend_statistic}, rejected")
ax.set_xlabel("Segment index")
ax.set_ylabel("Segment mean square")
ax.legend()
plt.show()
```

The result records the per-segment sequence (`segment_values`,
`segment_times`), the count, the Table A.6 `bounds`, the exact `p_value`
and the `stationary` verdict; `.plot()` draws the sequence with the verdict
in the legend. Note that the same reverse-arrangement count answers to two
different attribute names in the two result classes, because only one of them
has a per-segment sequence to carry:

| | `trend_test` → `TrendTestResult` | `stationarity_test` → `StationarityTestResult` |
| :--- | :--- | :--- |
| the count $A$ | `statistic` | `trend_statistic` |
| the verdict | `trend_free` | `stationary` |
| acceptance region | `bounds` (half-open) | `bounds` (half-open) |
| exact p-value | `p_value` | `p_value` |
| the sequence | `values` | `segment_values`, `segment_times`, `n_segments` |

The default of 20 segments matches the book's worked examples - more segments
resolve faster drifts but each interval must stay long against the record's
lowest frequencies for the values to be independent.

**How small a drift can it see?** Each segment mean square is itself a random
variable: for a band of width $B$ observed for $T_\text{seg}$ seconds its
normalized random error is $1/\sqrt{B\,T_\text{seg}}$. Take the default 20
segments over a 10 s record of the 1 kHz one-third-octave band
($B = 231$ Hz, $T_\text{seg} = 0.5$ s): $BT = 116$, so each segment value
scatters by about 9 %, which is 0.4 dB. A drift much smaller than that cannot be
separated from the scatter, while a monotonic drift of a couple of segment
standard deviations across the record is rejected almost every time.

Two design consequences follow, and they point in opposite directions to the
obvious move. To see a *smaller* drift, lengthen the **record**, not the segment
count: the scatter falls as $1/\sqrt{T_\text{seg}}$ while the trend stays put,
so splitting the same record into more segments makes each one noisier. And keep
$T_\text{seg}$ well above $1/B$: at least $BT = 5$ per interval, and no fewer
than ten cycles of the lowest frequency of interest. Otherwise, the segment
values stop being independent and the tabulated acceptance region no longer
applies. A
20-segment test of a record band-limited to 20 Hz and above therefore needs
intervals of at least 0.5 s, and so a record of at least 10 s.

One shape of nonstationarity escapes this test by construction: a source that
alternates between two steady states (a machine that loads and unloads, traffic
in platoons) produces a non-monotonic segment sequence that the reverse
arrangement test can happily accept while the record is plainly not stationary.
That is what `method="runs"` in section 3 is for, and the honest answer is
usually to split the record by state (`segment_times` shows where) and qualify
each part on its own.

Two caveats from the book are worth repeating. A record can be
nonstationary with a stationary mean square (a frequency glide, for
instance), so pass `statistic="mean"` or test band-filtered versions when
that matters; and the test needs the *trend* to be slow against the segment
length, or it dissolves into the random fluctuation of the segment values.

The first caveat is the one that costs a reader a wrong result, because it makes
the test *accept* a record it should reject. It is worth seeing:

![Three stacked panels. Top: the instantaneous frequency of a constant-amplitude glide rising linearly from 200 Hz to 2 kHz over eight seconds, with the 200 to 400 Hz band shaded. Middle: the twenty segment mean squares of the full-band record, flat at 0.5 with a reverse arrangement count of 96 inside the acceptance region, accepted. Bottom: the same record band-limited to 200 to 400 Hz, whose segment mean squares collapse to zero after the third segment, giving a count of 173 above the upper bound, rejected](https://docs.jmrp.io/phonometry/media/stationarity_glide_blind_spot.svg)

*A constant-amplitude glide from 200 Hz to 2 kHz is as nonstationary as a record
gets, and the full-band mean square cannot see it: the twenty segment values span
0.4998 to 0.5002 and the count $A = 96$ sits comfortably inside $(64, 125]$.
Band-limit the same record to 200-400 Hz first and the segment values collapse
once the glide leaves the band, giving $A = 173$, above the upper bound, and
rejected. The remedy in the caveat above is not a formality: what the test sees
depends entirely on the statistic and the band you hand it.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import signal

# stationarity_test is the one imported in section 2 above.
fs = 8192.0
t = np.arange(1 << 16) / fs
glide = np.sin(2 * np.pi * (200 * t + (2000 - 200) / (2 * t[-1]) * t ** 2))
sos = signal.butter(6, [200 / (fs / 2), 400 / (fs / 2)], btype="band",
                    output="sos")

full = metrology.stationarity_test(glide, fs)
banded = metrology.stationarity_test(signal.sosfiltfilt(sos, glide), fs)
print(full.trend_statistic, full.stationary)       # 96 True   -- blind
print(banded.trend_statistic, banded.stationary)   # 173 False -- caught

fig, (ax1, ax2) = plt.subplots(2, 1, figsize=(10, 7))
for ax, res, label in ((ax1, full, "full band"),
                       (ax2, banded, "200-400 Hz")):
    ax.plot(np.arange(1, res.n_segments + 1), res.segment_values, "o-")
    ax.set_ylim(-0.03, 0.58)
    ax.set_title(f"{label}: A = {res.trend_statistic}, accept {res.bounds}")
    ax.set_xlabel("Segment index")
    ax.set_ylabel("Segment mean square")
plt.show()
```

## 3. The runs test

The classical companion (tabulated in the third edition of *Random Data*;
the exact distribution is Wald & Wolfowitz 1940) classifies each value as
above or below the sequence median and counts **runs** of like
classification. A trend or slow drift produces few long runs; rapid
alternation produces too many. `method="runs"` applies it with the exact
conditional distribution at any $N$ - for twenty values split 10/10 the
acceptance region at $\alpha = 0.05$ is the classical $(6, 15]$:

```python
import numpy as np
from phonometry import metrology

rng = np.random.default_rng(3)
res = metrology.trend_test(rng.standard_normal(40), method="runs")
print(res.statistic, res.bounds, res.trend_free)
res.plot()   # the sequence about its median with the runs verdict

alternating = np.tile([1.0, -1.0], 10)   # 20 runs: rejected the other way
print(metrology.trend_test(alternating, method="runs").trend_free)   # False
```

![Two panels of sequences classified about their median, points above in blue and below in red. Left: forty Gaussian observations with twenty runs inside the acceptance region from fourteen to twenty-seven, verdict trend-free. Right: a strictly alternating twenty-value sequence also giving twenty runs, but against the acceptance region from six to fifteen for twenty values, verdict rejected for too-rapid alternation](https://docs.jmrp.io/phonometry/media/runs_test.svg)

*The two-sided verdict of the runs test: 20 runs is unremarkable for 40
Gaussian observations (left, accepted), but the same count from a strictly
alternating 20-value sequence exceeds its upper bound (right, rejected):
too **many** runs is as non-random as too few.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import metrology

rng = np.random.default_rng(3)
sequences = [rng.standard_normal(40), np.tile([1.0, -1.0], 10)]

# One line per sequence — the tested values with the verdict:
metrology.trend_test(sequences[0], method="runs").plot()
plt.show()

# Both verdicts side by side, classified about the median:
fig, axes = plt.subplots(1, 2, figsize=(11, 4.5))
for ax, seq in zip(axes, sequences):
    res = metrology.trend_test(seq, method="runs")
    idx = np.arange(1, seq.size + 1)
    median = np.median(seq)
    above = seq > median
    ax.plot(idx, seq, "0.7", lw=0.7)
    ax.scatter(idx[above], seq[above], label="above the median")
    ax.scatter(idx[~above], seq[~above], color="r",
               label="below the median")
    ax.axhline(median, color="k", linestyle="--")
    lo, hi = res.bounds
    verdict = "trend-free" if res.trend_free else "rejected"
    ax.set_title(f"r = {res.statistic} runs, accept ({lo}, {hi}]: {verdict}")
    ax.set(xlabel="Sample index", ylabel="Sequence value")
    ax.legend()
plt.show()
```

The reverse arrangement test is the more powerful of the two against the
monotonic trends that dominate practice (B&P Sec. 4.5.2), which is why it
is the default everywhere; the runs test adds sensitivity to non-monotonic
clustering.

## 4. Level crossings and the apparent frequency

For a zero-mean Gaussian record with one-sided autospectrum $G(f)$, Rice's
classical results give the expected rate of zero crossings (both slopes,
B&P Eq. (5.195)) from the plain frequency moments
$m_k = \int f^k\,G(f)\,\mathrm{d}f$:

$$
N_0 = \frac{1}{\pi}\frac{\sigma_v}{\sigma_x} = 2\sqrt{\frac{m_2}{m_0}},
\qquad
N_a = N_0\, \mathrm{e}^{-a^2/2\sigma_x^2},
$$

where $N_a$ is the crossing rate of level $a$ (Eq. (5.196)). $N_0/2$ is the
record's **apparent frequency**: a 60 Hz sine crosses zero 120 times per
second, low-pass noise of bandwidth $B$ gives $N_0 = 2B/\sqrt{3}$ (an
apparent frequency of $0.58B$, Example 5.12) and a band centred on $f_\mathrm{c}$
gives $N_0 = 2\sqrt{f_\mathrm{c}^2 + B^2/12}$ (Example 5.13).
`level_crossing_rate` counts the actual crossings of each level and puts
the Rice curve next to them, taking the moments from the record's own
[Welch autospectrum](https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/):

```python
import numpy as np
from phonometry import metrology

fs = 8192.0
t = np.arange(1 << 16) / fs
x = np.sin(2 * np.pi * 60.0 * t)          # a 60 Hz sine ...

res = metrology.level_crossing_rate(x, fs)
print(round(res.zero_crossing_rate, 1))   # ... has 120 zeros per second
print(round(res.apparent_frequency, 1))   # 60.0
res.plot()
```

![Measured level-crossing rates of a bandlimited Gaussian noise record between eight hundred and twelve hundred hertz, plotted as dots against the crossing level from minus three point five to plus three point five signal units on a logarithmic rate axis, falling from about two thousand crossings per second at level zero to a few per second at three sigma, with the Rice exponential curve passing through every measured point](https://docs.jmrp.io/phonometry/media/rice_level_crossings.svg)

*Two moments of the spectrum predict a curve spanning nearly three decades of
rate. The measured zero-crossing rate of this 800-1200 Hz record is
2012.7 crossings per second against Example 5.13's closed form
$2\sqrt{f_\mathrm{c}^2 + B^2/12} = 2013.3$, an apparent frequency of 1007 Hz; from there
the Rice exponential $N_a = N_0 \mathrm{e}^{-a^2/2\sigma_x^2}$ tracks the counts to
within 2 % out to $2\sigma$, where the rate has already fallen to 268/s. Past
$3\sigma$ the count is a handful of events per second and the scatter is the
statistics of the record, not a failure of the model.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import metrology

fs = 20480.0
n = 1 << 19
rng = np.random.default_rng(0)
freqs = np.fft.rfftfreq(n, 1 / fs)        # bandlimited Gaussian noise:
spec = rng.standard_normal(freqs.size) + 1j * rng.standard_normal(freqs.size)
spec[(freqs < 800.0) | (freqs > 1200.0)] = 0.0
x = np.fft.irfft(spec, n)

res = metrology.level_crossing_rate(x, fs, levels=np.linspace(-3.5, 3.5, 29) * np.std(x))

fig, ax = plt.subplots(figsize=(10, 6))
ax.plot(res.levels, res.rice_rates, label="Rice (Eq. 5.196)")
ax.plot(res.levels, res.rates, "o", label="Measured")
ax.set_yscale("log")
ax.set_xlabel("Level a [signal units]")
ax.set_ylabel("Crossings per second [1/s]")
ax.legend()
plt.show()
```

The Rice curve holds for Gaussian records, and that is precisely its second
use: measured rates that fall systematically off the curve are a quick
non-Gaussianity screen (B&P Sec. 5.5.1.1) - clipping shows up as missing
high-level crossings, impulsive contamination as an excess. Count-based
rates need the record comfortably oversampled: a crossing between two
samples of the same sign goes uncounted.

![Left: level-crossing rates of three records of the same variance and bandwidth against crossing level in units of sigma, each with its own Rice curve. The Gaussian reference lies on its curve, the record hard-clipped at 2.5 sigma has no crossings at all beyond the clip level, and the record with sparse six-sigma spikes lies above its curve in both tails. Right: the irregularity factor of a two-kilohertz low-pass record with a noise floor 50 decibels down, plotted against the analysis upper cut-off, flat at the closed-form 0.745 near the physical band and falling to 0.47 at 22 kilohertz](https://docs.jmrp.io/phonometry/media/rice_nongaussian_screen.svg)

*Left: what the screen actually looks like. Three records with the same variance
and the same 800-1200 Hz band, each drawn with its own Rice curve so the
deviation is a model mismatch and not a scaling artefact. The Gaussian reference
sits on the curve at every level. Hard clipping at 2.5σ leaves the rates
untouched below the clip level and removes them entirely above it: the signature
is a cliff, not a slope. Sparse 6σ spikes lift both tails above the curve beyond
about 2.5σ while barely moving the centre. Right: the companion warning of
section 5, measured. A record that is ideal low-pass noise to 2 kHz plus a flat
floor 50 dB down keeps $r$ at its closed-form 0.745 while the analysis band stays
near the physical one, and loses it as the band opens: 0.74 at 6 kHz, 0.71 at
13 kHz, 0.47 at 22 kHz. A noise floor you would never notice on a spectrum plot
costs a third of the irregularity factor once the analysis band is ten times too
wide.*

Finally, the low-frequency half of the same argument, which section 4 opened with
and never returned to: **the Rice formulas are written for a zero-mean process**.
Subtract the record mean and high-pass away everything below the physically
meaningful band before counting: 20 Hz for an audio-band acoustic record, the
transducer's own lower cut-off for a vibration record. Wind and building rumble
sit almost entirely in $m_0$ and contribute almost nothing to $m_2$, so they
inflate $\sigma_x$ while leaving $\sigma_v$ alone and bias $N_0$ and every
level-crossing rate low; a slow DC drift can suppress the crossings of the low
levels altogether, and a record that never returns to zero has no zero crossings
at all. The rule is symmetric: band-limit at both ends, the low end for $m_0$ and
the high end for $m_4$, and quote the band you used whenever you report an
apparent frequency or an irregularity factor, because neither number means
anything without it.

## 5. Peaks: rates, the irregularity factor and heights

The same moments fix the expected rate of local maxima
$M = (1/2\pi)(\sigma_a/\sigma_v) = \sqrt{m_4/m_2}$ (Eq. (5.211)) and with
it the dimensionless **irregularity factor**

$$
r = \frac{N_0}{2M} = \frac{m_2}{\sqrt{m_0\, m_4}} \in (0, 1],
$$

the single number that fixes the distribution of peak heights
(B&P Sec. 5.5.4). At $r = 1$ - narrow bandwidth data, one maximum per
zero-crossing cycle - peaks are **Rayleigh** distributed:
$\mathrm{Prob}[\text{peak} > a] = \mathrm{e}^{-a^2/2\sigma_x^2}$ (Eq. (5.206)), which
is the one-in-3000 chance of a peak beyond $4\sigma$ of B&P Example 5.14.
As $r \to 0$ ever more ripples ride on each cycle, negative maxima appear,
and the peak heights approach the plain **Gaussian** amplitude distribution.
In between, Rice's mixture (Eqs. (5.217)/(5.223)) interpolates the two,
available as `peak_exceedance()` / `peak_density()` on the result:

```python
import numpy as np
from phonometry import metrology

fs = 8192.0
t = np.arange(1 << 16) / fs
x = np.sin(2 * np.pi * 60.0 * t)          # narrowband: r is essentially 1

res = metrology.peak_statistics(x, fs)
print(round(res.irregularity_factor, 3))       # 0.997
print(round(res.peak_exceedance(4.0), 8))      # exp(-8): about 1 in 3000
res.plot()   # empirical exceedance against the Rice mixture (figure below)
```

![Peak-height exceedance probability of low-pass Gaussian noise on a logarithmic axis against the standardized peak height from minus two point five to four point five: the empirical staircase from half a million samples follows the Rice mixture curve for irregularity factor zero point seven four six, clearly below the dashed Rayleigh limit and above the dotted Gaussian limit, with a visible fraction of negative maxima](https://docs.jmrp.io/phonometry/media/rice_peak_distribution.svg)

*One number decides which curve the peaks follow. Ideal low-pass noise has the
closed-form $r = \sqrt5/3 = 0.745$, and the record measures 0.746, which is
also why 12.6 % of its 39 534 maxima are **negative**, an impossibility underRayleigh. The empirical staircase sits on the Rice mixture for that $r$ and
between the two limits everywhere: the chance of a peak beyond $4\sigma$ is
$2.5\times10^{-4}$, a quarter below the Rayleigh $\mathrm{e}^{-8} = 3.4\times10^{-4}$.
Assuming the Rayleigh limit on a record that is not narrowband over-predicts the
extremes.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import metrology
from phonometry.metrology.data_qualification import _rice_peak_exceedance

fs = 20480.0
n = 1 << 19
rng = np.random.default_rng(3)
freqs = np.fft.rfftfreq(n, 1 / fs)        # low-pass noise: r = sqrt(5)/3
spec = rng.standard_normal(freqs.size) + 1j * rng.standard_normal(freqs.size)
spec[freqs > 2000.0] = 0.0
x = np.fft.irfft(spec, n)

res = metrology.peak_statistics(x, fs)
peaks = res.peak_values
empirical = 1.0 - np.arange(1, peaks.size + 1) / peaks.size
z = np.linspace(-2.5, 4.5, 400)

fig, ax = plt.subplots(figsize=(10, 6))
ax.plot(z, _rice_peak_exceedance(z, 1.0), "--", label="Rayleigh (r = 1)")
ax.plot(z, _rice_peak_exceedance(z, 0.0), ":", label="Gaussian (r = 0)")
ax.plot(z, res.peak_exceedance(z),
        label=f"Rice (r = {res.irregularity_factor:.3f})")
ax.plot(peaks, empirical, drawstyle="steps-post", label="Empirical")
ax.set_yscale("log")
ax.set_ylim(1e-5, 1.5)
ax.set_xlabel(r"Standardized peak height $z = a/\sigma_x$")
ax.set_ylabel("Prob[peak > z]")
ax.legend()
plt.show()
```

For an ideal low-pass band the closed forms give $r = \sqrt{5}/3 = 0.745$,
and the measured value lands on it. The irregularity factor is the standard
bridge to fatigue and vibro-acoustic damage estimation, where it selects
the cycle-counting correction between the narrow-band Rayleigh assumption
and broad-band rainflow corrections. One practical warning: $m_4$ weights
the spectrum by $f^4$, so wideband instrumentation noise far above the
physical band silently inflates $M$ and deflates $r$ - band-limit the
record to the physically meaningful range first.

## Where this fits

Qualification comes *before* the statistics this section's other pages
compute: the chi-square confidence interval of a
[Welch PSD](https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/) and the random-error
formulas of the [correlation estimators](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/)
all assume the record is stationary, as does the very idea of *the* $L_\mathrm{eq}$ of
a measurement in [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/). When a record fails
the test, split it at the change (the `segment_values` sequence shows
where), analyse the pieces, or move to the short-time views - the
[calibrated spectrogram](https://docs.jmrp.io/phonometry/signals/spectra/time-frequency/) - that do not
assume stationarity. And when it passes, the
[GUM machinery](https://docs.jmrp.io/phonometry/signals/metrology/gum-uncertainty/) can propagate the
*remaining* random error of every averaged estimate with a clean
conscience.

## What this guide covers

- **Covered.** Bendat & Piersol Section 4.5.2 with Table A.6 (the reverse arrangement trend
  test, `trend_test`, its exact and normal-approximation p-value and Example
  4.4), the Wald & Wolfowitz (1940) runs test (`trend_test(method="runs")`), the
  Section 10.3.1.1 segment mean-square stationarity procedure with Example 10.3
  (`stationarity_test`), and the Rice (1945) level-crossing and peak statistics
  of Section 5.5 (`level_crossing_rate`, `peak_statistics`, the irregularity
  factor and its Rayleigh/Gaussian peak-height limits).

- **Not covered.** Section 10.3 of the book is titled "data qualification" more broadly and also
  covers classification, validation and editing procedures;
  `phonometry.metrology` implements only its quantitative core, the segment
  mean-square stationarity test. Classifying a record's type, validating it
  against physical limits, or editing out glitches stay manual steps the way the
  book describes them, outside this module.

## See also

- [Spectral analysis](https://docs.jmrp.io/phonometry/signals/spectra/spectral-analysis/): the chi-square confidence interval that assumes the stationarity this page tests.
- [Time-frequency analysis](https://docs.jmrp.io/phonometry/signals/spectra/time-frequency/): the short-time view for records that fail the test, and for the glides its mean square cannot see.
- [GUM uncertainty](https://docs.jmrp.io/phonometry/signals/metrology/gum-uncertainty/): propagating the remaining random error of a qualified average.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): the $L_\mathrm{eq}$ whose definition assumes one stationary measurement.
- API reference: [`metrology.data_qualification`](https://docs.jmrp.io/phonometry/reference/api/metrology/data-qualification/).
- Theory: [Measurement uncertainty (GUM)](https://docs.jmrp.io/phonometry/reference/theory/signal-analysis/#measurement-uncertainty-isoiec-guide-98-3-gum-and-supplement-1): the uncertainty framework the qualification criteria of this page feed.

## References

- **Bendat, J. S., & Piersol, A. G. (2010).** *Random data: Analysis and measurement procedures* (4th ed.). Wiley. https://doi.org/10.1002/9781118032428
  Section 4.5.2 with Table A.6 (the nonparametric reverse arrangement trend test, its mean and variance, the tabulated percentage points and Example 4.4), Section 10.3 (data qualification: classification, validation, editing; the segment mean-square stationarity procedure of 10.3.1.1 and Example 10.3) and Section 5.5 (level crossings and peak values: Eqs. (5.195)-(5.196), (5.206), (5.211), (5.217)-(5.223) and Examples 5.12-5.15). ISBN 978-0-470-24877-5. The runs companion appeared in the third edition's percentage points of the run distribution.
- **Rice, S. O. (1945).** Mathematical analysis of random noise. *The Bell System Technical Journal*, *24*(1), 46-156. https://doi.org/10.1002/j.1538-7305.1945.tb00453.x
  The original derivations of the expected level-crossing and maxima rates and the peak distribution of Gaussian noise that Bendat & Piersol Section 5.5 presents (their Ref. 6; Parts I-II are in volume 23, 1944).
- **Wald, A., & Wolfowitz, J. (1940).** On a test whether two samples are from the same population. *The Annals of Mathematical Statistics*, *11*(2), 147-162. https://doi.org/10.1214/aoms/1177731909
  The exact conditional distribution of the number of runs, from which the runs-about-the-median acceptance regions are computed.