# Time Weighting

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/signals/levels/time-weighting/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/signals/levels/time-weighting/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-05
Updated: 2026-11-16T21:36:12Z
Standards: IEC 61672-1:2013; ANSI S1.4-1983
Verified: 51 conformance checks (IEC 61672-1:2013; ANSI S1.4-1983) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: IEC 61672-1:2013 exponential detector: Fast and Slow, the dropped Impulse ballistics, tone-burst verification (Table 4), initial state and streaming.

---

A displayed sound level is always a *time-weighted* level: before anything
reaches the readout, the squared, frequency-weighted pressure passes
through an exponential detector whose time constant sets how quickly the
level follows the signal. This page is that detector, implemented as a
sample-exact recursive filter: the Fast and Slow characteristics of
IEC 61672-1:2013 (clause 5.8), the legacy asymmetric Impulse ballistics,
streaming state for block processing, and the toneburst verification
against the standard's Table 4.

The names are older than the mathematics. FAST and SLOW were literal
descriptions of a needle movement, standardized for analog meters in
ANSI S1.4-1983 and IEC 60651 and carried into IEC 61672-1 as the F and S
exponential constants; IMPULSE was added in the same era for impact noise
and has since been dropped from the requirements, surviving in instruments
only for legacy procedures (the [choosing guidance](#choosing-f-s-or-i)
below says when each is defensible; Bies, Hansen & Howard 2017, §3.6
covers the instrument practice).

Two sibling pages complete the chain. The detector output is the level
track that the percentile levels $L_N$ of
[Integrated and Statistical Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) are
defined on, while the integrated
metrics ($L_\mathrm{eq}$, SEL) bypass the detector entirely; and the full
IEC 61672-1 instrument chain that wraps this detector (weighting, ranges,
periodic tests) is the subject of
[Build a sound level meter](https://docs.jmrp.io/phonometry/signals/sound-level-meter/).

## 1. The exponential detector

A sound level meter's needle cannot follow the pressure waveform: it shows a
running *mean square* with an exponential memory. Formally (IEC 61672-1, 3.8):

$$
\tau\ \frac{dy}{dt} + y = x^2(t)
\quad\Longleftrightarrow\quad
y(t) = \frac{1}{\tau} \int_{-\infty}^{t} x^2(\xi)\ \mathrm{e}^{-(t-\xi)/\tau}\ d\xi
$$

a first-order low-pass on the squared signal. The time constant $\tau$ sets the
trade-off: **Fast** (125 ms) follows speech-like fluctuations, **Slow** (1 s)
steadies the readout for quasi-stationary noise. After a step onset the
envelope reaches 63 % of its final value in one $\tau$ and ~99.97 % after
$8\tau$;
that is why level analyses discard the first instants of a recording.

![The exponential-detector chain: the band pressure is squared, smoothed by a one-pole RC low-pass with time constant tau, and converted to decibels, with the Fast, Slow and Impulse time constants listed](https://docs.jmrp.io/phonometry/media/diagram_time_weighting.svg)

## 2. The three time weightings

* **Fast (`fast`):** $\tau = 125\ \text{ms}$. Standard for noise fluctuations.
* **Slow (`slow`):** $\tau = 1000\ \text{ms}$. Standard for steady noise.
* **Impulse (`impulse`):** **Asymmetric** ballistics, 35 ms attack and 1.5 s
  decay. Both numbers are specified, not tuned: ANSI S1.4-1983 clause 2.7
  defines the impulse sound level as 35 ms exponential time averaging for
  increasing portions of the signal and a 1500 ms time constant for decreasing
  portions.

**Video:** [The Fast, Slow and Impulse detector ballistics](https://docs.jmrp.io/phonometry/media/anim_time_weighting.webm): A tone burst drives the RC exponential detector: the capacitor charges and drains while the Fast, Slow and Impulse meter needles follow their own ballistics, and the three level traces build up below to show the fast attack, the slow average and the asymmetric impulse hold.

![Fast, Slow and Impulse time weighting responses to a noise burst](https://docs.jmrp.io/phonometry/media/time_weighting_analysis.svg)

*The three detectors on one 0.5 s noise burst: Fast rises and falls with it,
Slow never reaches its level, and Impulse rises with Fast and then holds.*

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from phonometry import filters

fs = 48000
t = np.arange(int(fs * 4)) / fs
burst = np.zeros_like(t)  # 0.5 s noise burst (Pa) starting at t = 1 s
rng = np.random.default_rng(42)
burst[fs:int(1.5 * fs)] = 0.2 * rng.standard_normal(int(0.5 * fs))

p0 = 2e-5
plt.figure()
for mode in ('fast', 'slow', 'impulse'):
    envelope = filters.time_weighting(burst, fs, mode=mode)
    plt.plot(t, 10 * np.log10(np.maximum(envelope, 1e-12) / p0**2), label=mode)
plt.xlabel('Time [s]')
plt.ylabel('Level [dB SPL]')
plt.legend()
plt.show()
```

```python
import numpy as np
from phonometry import filters

# recording: a calibrated microphone capture (Pa) — recorded through your measurement chain. Synthesized here so the guide runs standalone.
fs = 48000
recording = 0.2 * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs)

# Calculate energy envelope (Mean Square)
energy_envelope = filters.time_weighting(recording, fs, mode='fast')
# dB SPL relative to 20 μPa
spl_t = 10 * np.log10(energy_envelope / (2e-5)**2)

print(f"Steady-state Fast level: {spl_t[-1]:.1f} dB SPL")
# Steady-state Fast level: 77.0 dB SPL
```

The asymmetric Impulse ballistics use two constants, a fast attack and a slow
decay, switching per sample on the sign of the change:

$$
y[n] = y[n-1] + \alpha \ (x^2[n] - y[n-1]), \qquad
\alpha = \begin{cases}1 - \mathrm{e}^{-1/(f_\mathrm{s} \cdot 0.035)} & x^2[n] > y[n-1]\\[2pt] 1 - \mathrm{e}^{-1/(f_\mathrm{s} \cdot 1.5)} & \text{otherwise}\end{cases}
$$

A time constant and a decay rate are the same statement. An exponentially
decaying mean square falls at a constant $10/(\tau \ln 10)$ decibels per
second, which is why IEC 61672-1 clause 5.8.1 can specify F and S twice over:
as design-goal constants of 0.125 s and 1 s, and as design-goal decay rates of
34.7 dB/s and 4.3 dB/s. The same arithmetic turns the 1.5 s decreasing-portion
constant of the analog IMPULSE characteristic into 2.9 dB/s, the fall an
operator was meant to be able to read off a moving needle.

The asymmetry has a consequence worth stating: unlike F and S, Impulse is not a
filter. Its coefficient depends on the signal, so an I-weighted level is not
additive; the I-weighted level of two sources running together cannot be
derived from the two measured separately, while their $L_\mathrm{eq}$ values can.

### Choosing F, S or I

- **Fast** is the default of nearly every modern method: percentile levels,
  impulsive-event detection, community noise, the general "level vs time"
  plot. Its 125 ms constant is of the same order as the ear's own loudness
  integration time, so an $L_\mathrm{AF}$ trace roughly tracks what a listener notices.
- **Slow** suits quasi-stationary sources and any procedure that needs a
  steady readout: it averages away the flicker of a fluctuating source at
  the price of missing short events (a 100 ms burst peaks 7.6 dB lower
  on S than on F). Some legacy methods prescribe it outright, most famously
  aircraft-certification levels, which are built from Slow-weighted samples.
- **Impulse** is legacy, and deprecated for rating. It was a 1960s attempt
  to make a meter needle track the perceived loudness of impacts; it does
  not (the 35 ms attack still misses very short impulses, and the 1.5 s decay
  exaggerates duration). It entered the international standards with
  IEC 60651 and was dropped from the requirements of its successor
  IEC 61672-1, whose first edition (2002) explains why: I-weighted levels
  are not suitable for rating impulsive sounds. Modern *international*
  practice rates impulsiveness with
  $L_\mathrm{Aeq}$ plus an adjustment (ISO 1996-1 Table A.1, or the onset analysis
  of [Impulsive-sound prominence](https://docs.jmrp.io/phonometry/environment/assessment/impulsive-sound/)) and assesses
  hearing-damage risk with $L_\mathrm{Cpeak}$, never with I-weighted levels. Some
  national rules still require the I weighting explicitly: the Spanish
  RD 1367/2007 grades its impulsive correction $K_\mathrm{i}$ on
  $L_\mathrm{AIeq} - L_\mathrm{Aeq}$ (see
  [Spanish Noise Regulation](https://docs.jmrp.io/phonometry/environment/assessment/spanish-noise-regulation/)),
  which is why `mode='impulse'` is a first-class option here and not a
  compatibility shim.

![Peak envelope level relative to the steady reading, in decibels, against tone-burst duration from one millisecond to two seconds on a logarithmic axis, with one measured curve per detector: Impulse highest, then Fast, then Slow. All three approach zero decibels for bursts of a second or more and fall steeply for short ones, reaching minus 18, minus 21 and minus 30 decibels at one millisecond. Open circles from IEC 61672-1 Table 4 Equation 7 sit exactly on the Fast and Slow curves, a vertical marker at 100 milliseconds annotates the 7.6 decibel gap between Fast and Slow there, and an annotation notes that even Impulse loses 18 decibels on a one-millisecond burst](https://docs.jmrp.io/phonometry/media/ballistics_vs_duration.svg)

*How much of an event each detector keeps, as a function of how long the event
lasts. The measured curves land on the Table 4 reference points, so the whole
table is one line of algebra. The gap between two curves at a given duration is
the reason a maximum level has to name its time weighting; and the absolute
loss is why very short impulses are rated with $L_\mathrm{Cpeak}$ instead: even
Impulse, the ballistics designed for impacts, is 18 dB low on a 1 ms burst.*

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt

fs = 48000
t = np.arange(int(3.0 * fs)) / fs
tone = np.sin(2 * np.pi * 4000 * t)
durations = np.geomspace(0.001, 2.0, 30)

plt.figure()
for mode in ('fast', 'slow', 'impulse'):
    reference = filters.time_weighting(tone, fs, mode=mode)[int(2.5 * fs):].mean()
    peaks = []
    for t_b in durations:
        burst = np.zeros_like(t)
        stop = int(0.5 * fs) + int(t_b * fs)
        burst[int(0.5 * fs):stop] = tone[int(0.5 * fs):stop]
        peaks.append(10 * np.log10(
            filters.time_weighting(burst, fs, mode=mode).max() / reference))
    plt.semilogx(durations * 1e3, peaks, label=mode)
plt.axvline(100.0, linewidth=0.8)
plt.xlabel('Toneburst duration [ms]')
plt.ylabel('Peak level re the steady reading [dB]')
plt.legend()
plt.show()
```

## 3. `time_weighting()` / `TimeWeighting` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D or 2D array, or `Signal` | pressure (any scale) | non-empty | Squared internally; output is a mean-square envelope |
| `fs` | int | Hz | > 0; taken from `x` when `x` is a `Signal` | |
| `mode` | str | — | `'fast'` (default), `'slow'`, `'impulse'` | $\tau$ = 125 ms / 1 s / 35 ms attack + 1.5 s decay |
| `initial_state` | `None` / `'zero'` / `'first'` / float / array | mean square of $x$ | default `None` (= `'zero'`) | Integrator state $y[-1]$; see sections 5 and 6 |
| `TimeWeighting(fs, mode)` (class) | — | — | — | Stateful variant for streaming: `process(x)` carries the integrator state between blocks |
| `TimeWeighting.reset()` | — | — | — | Drops the carried state so the next `process()` starts from rest |

The output has the units of $x^2$: take `10*log10(y / p0**2)` for SPL or use
the level functions, which do it for you.

## 4. Verified ballistics (IEC 61672-1 Table 4)

Those reference values are not a lookup table with no formula behind it.
IEC 61672-1 gives them in Note 1 to Table 4 as Equation (7), the exact response
of the section 1 detector to an isolated 4 kHz toneburst of duration $T_\mathrm{b}$:

$$
\Delta_{\mathrm{ref}} = 10\log_{10}\left(1 - \mathrm{e}^{-T_\mathrm{b}/\tau}\right)\ \text{dB}
$$

Read it out loud and the whole table follows. On Fast ($\tau = 125$ ms) a
200 ms burst gives $-0.98$ dB, a 50 ms burst $-4.82$ dB and a 10 ms burst
$-11.14$ dB (the three panels below). A 100 ms burst gives $-2.59$ dB on Fast
and $-10.21$ dB on Slow, and that 7.6 dB is the number quoted in the
[choosing guidance](#choosing-f-s-or-i) above. The physics is one sentence: a
detector with memory $\tau$ cannot reach its steady value on an event shorter
than $\tau$, so **every meter under-reads every short event**, by an amount
that depends only on $T_\mathrm{b}/\tau$. That is why a maximum level is meaningless
without its ballistics, and why impulses short compared with 125 ms are rated
with $L_\mathrm{Cpeak}$ instead.

The Fast envelope's response to 4 kHz tonebursts lands exactly on the
standard's reference values: the example below verifies the three Table 4 rows
drawn in the figure; the CI suite covers the full table, from 1 s down to 1 ms
for F and 1 s down to 2 ms for S, at class 1 acceptance limits:

![Fast envelope responses to 200, 50 and 10 ms tone bursts peaking exactly at the IEC 61672-1 Table 4 reference values](https://docs.jmrp.io/phonometry/media/tone_burst_iec.svg)

*Fast envelope peaks at −1.0, −4.8 and −11.1 dB relative to the steady tone for
the 200, 50 and 10 ms bursts of Table 4; the CI suite checks the full table
from 1 s down to 1 ms.*

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from phonometry import filters

fs = 48000
t = np.arange(int(fs * 2)) / fs
tone = np.sin(2 * np.pi * 4000 * t)

# Steady-state Fast reference of the continuous tone
reference = filters.time_weighting(tone, fs, mode='fast')[int(1.5 * fs):].mean()

# The three Table 4 rows the published figure draws, with their targets
cases = [(0.200, -1.0), (0.050, -4.8), (0.010, -11.1)]
fig, axes = plt.subplots(len(cases), 1, sharey=True, figsize=(8, 8))
for ax, (t_b, target) in zip(axes, cases):
    burst = np.zeros_like(t)
    stop = int(0.5 * fs) + int(t_b * fs)
    burst[int(0.5 * fs):stop] = tone[int(0.5 * fs):stop]
    envelope = filters.time_weighting(burst, fs, mode='fast')
    env_db = 10 * np.log10(np.maximum(envelope / reference, 1e-6))
    ax.plot(t, env_db, label=f'Fast envelope, {t_b * 1e3:.0f} ms burst')
    ax.axhline(target, linestyle='--', label=f'IEC target {target} dB')
    ax.set_ylabel('Level re steady state [dB]')
    ax.legend(loc='upper right')
axes[-1].set_xlabel('Time [s]')
plt.show()
```

## 5. Initial state

The integrator needs a starting value for $y[-1]$, and there are four ways to
give it.

- **`None` (the default) and `'zero'` are the same thing**, a start from rest, so
  the level climbs through the settling ramp of section 1.
- **`'first'` seeds it with the square of the very first sample**, $x[0]^2$. That
  is an unbiased but extremely noisy estimate of the mean square (one degree of
  freedom) and for a tone it depends entirely on the phase at the cut. In the
  snippet below it is *exactly zero*, because a sine starting at $t = 0$ starts
  at a zero crossing, so `'first'` there is bit-identical to `'zero'`.
- **A float** resumes a state you saved yourself, which is what block processing
  does in section 6.
- **An array** broadcastable to the input shape without the time axis does the
  same per channel.

If the record is a continuation of a signal already running, seed the integrator
with something robust: the mean square of the first half second,
`initial_state=float(np.mean(recording[:fs // 2] ** 2))`, is a far better
estimate than a single sample. If the record is the *start* of the event, do not
seed at all: let it start from rest and discard the first $5\tau$ (0.6 s Fast,
5 s Slow), which is exactly what `ln_levels` does internally before computing
percentiles.

```python
import numpy as np
from phonometry import filters

# recording: a calibrated microphone capture (Pa) — recorded through your measurement chain. Synthesized here so the guide runs standalone.
fs = 48000
recording = 0.2 * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs)

# Robust seed: the mean square of the first half second, not one sample.
energy_envelope = filters.time_weighting(
    recording, fs, mode='fast',
    initial_state=float(np.mean(recording[:fs // 2] ** 2)))
```

## 6. Block processing

For block processing, pass the last output value from the previous block as the
next block's `initial_state` instead of resetting each block:

```python
from phonometry import filters

state = None

# audio_blocks: consecutive frames of your calibrated recording (Pa),
#   streamed from your sound card or read from a WAV in blocks.
for block in audio_blocks:
    energy_envelope = filters.time_weighting(block, fs, mode='fast', initial_state=state)
    state = energy_envelope[-1]
```

For multichannel blocks with time on the last axis, carry one state per channel:
use `state = energy_envelope[..., -1]`. A scalar `initial_state` is applied to
every channel, while an array must match or broadcast to the non-time shape,
such as `(n_channels,)` for input shaped `(n_channels, n_samples)`.

Or let the `TimeWeighting` class carry the state for you:

```python
from phonometry import filters

tw = filters.TimeWeighting(fs, mode='fast')
# audio_blocks: consecutive frames of your calibrated recording (Pa),
#   streamed from your sound card or read from a WAV in blocks.
for block in audio_blocks:
    energy_envelope = tw.process(block)
```

Concatenated block outputs are exactly equal to a single continuous call
(verified for all three modes, mono and multichannel). Call `tw.reset()` to
start from rest again.

## 7. Performance note

The `impulse` mode uses an asymmetric kernel that is JIT-compiled when
[numba](https://numba.pydata.org/) is installed (`pip install "phonometry[perf]"`).
Without numba a pure-Python fallback produces identical results, just slower.

See [Integrated and Statistical Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) for
$L_\mathrm{eq}$/$L_N$ metrics built on these envelopes, and
[Why phonometry](https://docs.jmrp.io/phonometry/start/why-phonometry/) for the IEC
61672-1 tone-burst verification.

## What this guide covers

- **Covered.** IEC 61672-1:2013's exponential time-weighting detector (clause 3.8) with the
  Fast and Slow time constants (clause 5.8.1), implemented as the recursive
  filter of `time_weighting` and the streaming `TimeWeighting` class, verified
  in CI against the class 1 tone-burst references of Table 4. The legacy
  asymmetric Impulse ballistics (35 ms attack, 1.5 s decay), carried into the
  international standards from the FAST/SLOW/IMPULSE characteristics of ANSI
  S1.4-1983.

- **Not covered.** IEC 61672-1's wider instrument chain (frequency weighting, level ranges,
  periodic tests) is not on this page; it is the subject of [Build a sound level
  meter](https://docs.jmrp.io/phonometry/signals/sound-level-meter/). ANSI S1.4-1983 is cited only
  for the historical origin of the F and S constants, not implemented as its own
  instrument specification. Modern impulsiveness rating ($L_\mathrm{Aeq}$ plus an
  adjustment, or onset analysis) is on the [Impulsive-sound
  prominence](https://docs.jmrp.io/phonometry/environment/assessment/impulsive-sound/) page, not
  built on the Impulse weighting here.

## See also

- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): the percentile levels defined on the detector's output, and the integrated metrics that bypass it.
- [Build a sound level meter](https://docs.jmrp.io/phonometry/signals/sound-level-meter/): the complete IEC 61672-1 instrument chain around this detector.
- [Frequency Weighting](https://docs.jmrp.io/phonometry/signals/levels/weighting/): the A/C/Z filters applied before the detector.
- [Block Processing](https://docs.jmrp.io/phonometry/signals/filters/block-processing/): streaming the detector over frames without state discontinuities.
- [Impulsive-sound prominence](https://docs.jmrp.io/phonometry/environment/assessment/impulsive-sound/): the onset-based rating of impulses that the international standards moved to.
- [Spanish Noise Regulation](https://docs.jmrp.io/phonometry/environment/assessment/spanish-noise-regulation/): a rating in force that still requires the I weighting, through the $L_\mathrm{AIeq} - L_\mathrm{Aeq}$ impulsive correction $K_\mathrm{i}$.
- [Calibration and dBFS](https://docs.jmrp.io/phonometry/signals/metrology/calibration/): the IEC 61672-3 periodic tests, in which these ballistics are spot-checked against the class limits on a real instrument.
- API reference: [`filters.weighting`](https://docs.jmrp.io/phonometry/reference/api/filters/weighting/).
- Theory: [Time Integration](https://docs.jmrp.io/phonometry/reference/theory/signal-analysis/#time-integration): the first-order equation the exponential detectors solve, and what integrating it over a fixed block instead would change.

## Quick answers

### Which time weighting should I use, and which is the default?

`filters.time_weighting(x, fs)` and `TimeWeighting` use Fast unless `mode`
names another, and Fast is what nearly every current method expects: percentile
levels, event detection, community noise and the level-against-time plot. Slow
suits quasi-stationary sources and the procedures that prescribe it, aircraft
certification among them. Impulse is legacy: IEC 61672-1 dropped it from its
requirements and current practice rates impulsiveness on $L_\mathrm{Aeq}$ with
an adjustment, but the Spanish RD 1367/2007 still grades its impulsive
correction on $L_\mathrm{AIeq} - L_\mathrm{Aeq}$, which is why
`mode='impulse'` stays. The time constants are in
[The three time weightings](#2-the-three-time-weightings).

## References

- **American National Standards Institute. (1983).** [*Specification for sound level meters*](https://webstore.ansi.org/standards/asa/ansis11983r20064a1985) (ANSI S1.4-1983).
  The classic analog meter specification: the FAST/SLOW dynamic characteristics the F and S constants descend from, and the IMPULSE characteristic that IEC 61672-1 no longer specifies, defined in clause 2.7 as a 35 ms exponential-time-averaging constant for increasing portions of the signal and a 1500 ms constant for decreasing portions.
- **Bies, D. A., Hansen, C. H., & Howard, C. Q. (2017).** *Engineering noise control* (5th ed.). CRC Press. https://doi.org/10.1201/9781351228152
  Sections 3.2 and 3.6 (sound level meters and the measurement of time-varying sound: what the F/S/I readouts mean in instrument practice). ISBN 978-1-4987-2405-0.
- **International Electrotechnical Commission. (2013).** [*Electroacoustics — Sound level meters — Part 1: Specifications*](https://webstore.iec.ch/en/publication/5708) (IEC 61672-1:2013).
  The exponential time-weighting detector (clause 3.8) with the F and S design-goal time constants and decay rates (clause 5.8.1), the maximum time-weighted sound level (clause 3.7) and its hold feature (clause 5.1.14), and the 4 kHz toneburst reference responses of Table 4 and its Equation (7) (class 1 acceptance limits) the ballistics are verified against in CI.