# Special Weightings (G, B, D, AU)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/signals/levels/special-weightings/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/signals/levels/special-weightings/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-29
Updated: 2026-11-16T21:36:10Z
Standards: ISO 7196:1995; ANSI S1.4-1983; IEC 61012:1990; IEC 537:1976 (withdrawn); NASA CR-3406
Verified: 4 conformance checks (ISO 7196:1995; ANSI S1.4-1983; IEC 61012:1990; IEC 537:1976 (withdrawn)) https://docs.jmrp.io/phonometry/reference/conformance/#filters-weightings
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: G-weighting for infrasound (ISO 7196), historical B (ANSI S1.4-1983) and D (IEC 537), AU (IEC 61012) in the presence of ultrasound, and B and AU checks.

---

Beyond A, C and Z, the weighting family keeps four special-purpose curves,
each the right tool for a narrower job: the **G** curve of **ISO 7196:1995**
rates infrasound below 20 Hz the way A-weighting rates audible noise, the
historical **B** (ANSI S1.4-1983) reproduces measurements taken under older
national codes, the withdrawn aircraft-noise **D** (IEC 537) serves
comparisons with legacy data, and **AU** (IEC 61012), still in force like the
G curve, keeps ultrasonic components out of an audible-exposure reading.

All four share the machinery of the IEC 61672-1 curves (0 dB at 1 kHz where
applicable, multichannel and stateful block processing), and B, D and AU also
take the same default `high_accuracy` design: the analog prototype is fitted
at the sample rate rather than transformed blind, so the bilinear frequency
warping never reaches the response. For G that keeps its 0.25 Hz to 315 Hz
range within 0.0001 dB whatever the input rate, which matters exactly where G
is used: infrasound is often recorded at 1 kHz or 2 kHz, where 315 Hz sits
close to Nyquist and the warping grows quadratically. `high_accuracy=False`
gives the plain bilinear design instead, about a decibel low at 315 Hz at
fs = 2000 and exactly on the 0 dB reference at 10 Hz. Unlike before, the flag
is independent of `stateful`: block processing carries the fitted design too.
The A, C and Z curves themselves, where they come from, the
`high_accuracy` design and the class verification against IEC 61672-1
Table 3 are the subject of
[Frequency Weighting](https://docs.jmrp.io/phonometry/signals/levels/weighting/).

## 1. Infrasound: G-weighting (ISO 7196)

The **G frequency weighting** (ISO 7196:1995) rates infrasound the way A-weighting
rates audible noise. It is defined by a pole-zero configuration
normalized to 0 dB at 10 Hz, and it has three slopes, not two. Above 20 Hz the
response falls at 24 dB/octave, which keeps audible-range energy out of an
infrasound reading; between about 1 Hz and 20 Hz it *rises* at 12 dB/octave,
following the steep growth of infrasound perception; and below about 1 Hz it
rolls off again at 24 dB/octave, rejecting the near-static pressure
fluctuations (wind loading, barometric drift, building sway) that a
microphone records and nobody hears. Use it for sources with significant
energy below 20 Hz (wind turbines, HVAC, blasting):

```python
import numpy as np
from phonometry import filters

# recording: a calibrated microphone capture (Pa) — recorded through your measurement chain. Synthesized here so the guide runs standalone.
fs = 48000
recording = 0.2 * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs)

g_weighted = filters.weighting_filter(recording, fs, weighting='G')
```

![G-weighting frequency response from 0.1 Hz to 1 kHz with the ISO 7196 Table 2 nominal values overlaid](https://docs.jmrp.io/phonometry/media/g_weighting_response.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import filters

# Measure the G response: weight a centered unit impulse and take its
# spectrum. A long buffer gives the resolution the infrasound range
# needs (20 s -> 0.05 Hz).
fs = 4000
impulse = np.zeros(20 * fs)
impulse[impulse.size // 2] = 1.0
freqs = np.fft.rfftfreq(impulse.size, 1 / fs)
spectrum = np.fft.rfft(filters.weighting_filter(impulse, fs, weighting="G"))

fig, ax = plt.subplots(figsize=(9, 5))
ax.semilogx(freqs[1:],
            20 * np.log10(np.abs(spectrum[1:]) + np.finfo(float).eps))
ax.plot(10, 0, "o", color="tab:red", label="0 dB at 10 Hz")
ax.set(xlim=(0.1, 1000), ylim=(-90, 15),
       xlabel="Frequency [Hz]", ylabel="G-weighting response [dB]")
ax.grid(True, which="both", alpha=0.3)
ax.legend()
plt.show()
```

The implementation follows the ISO 7196 Table 1 pole/zero values exactly and is
verified in CI against every Table 2 nominal response value (0.25 Hz to 315 Hz).
`WeightingFilter(fs, "G")` supports the same multichannel and stateful block
processing as A/C, and streaming costs nothing: the design is the same cascade
of second-order sections either way, so stitched blocks reproduce a single
call exactly at any sample rate. Levels measured with the G curve are reported as
$L_{p\mathrm{G}}$ (or $L_\mathrm{Geq}$ for the equivalent level over time).

### Reading an LpG: the scale is not the dB(A) scale

A G-weighted level of 85 dB means nothing until you know what the scale looks
like, and it does not look like the audible one. ISO 7196's Introduction gives
the anchors: the normal threshold of perception at 10 Hz is about 100 dB re
20 µPa; sounds between 1 Hz and 20 Hz that are just perceptible to an average
listener yield G-weighted levels close to 100 dB; a very loud infrasound yields
a G-weighted level of the order of 120 dB, only 20 dB above; and G-weighted
levels below about 90 dB are not normally significant for human perception.

Two consequences follow. First, the useful range spans some 30 dB, not the
100 dB a reader is used to in dB(A), so **a few decibels matter far more here**:
an $L_{p\mathrm{G}}$ of 85 dB and one of 105 dB are not "similar", they are inaudible
and very loud. Second, because the growth of sensation with level is much more
rapid than in the audible range while the threshold itself varies between
individuals, a level near 100 dB(G) can be imperceptible to one person and
clearly perceived by another, which is why infrasound complaints are
investigated case by case. Compare an $L_{p\mathrm{G}}$ against these perception
anchors, never against an A-weighted limit, and never combine the two into one
number.

### Measuring infrasound, not just weighting it

The filter above is exact from 0.25 Hz. Almost no ordinary capture chain is,
and nothing in the code can tell. ISO 7196 Annex A specifies a chain, not only
a curve, and its first requirement (A.2) is a microphone with a substantially
constant or well-defined frequency response over at least 0.25 Hz to 160 Hz,
preferably to 315 Hz. A general-purpose measurement capsule cannot deliver
that: its static-pressure equalisation vent behaves as a first-order high-pass,
and a corner as high as 2 Hz already costs 7.0 dB at 1 Hz and 12.3 dB at
0.5 Hz. Any low-cut switch on the recorder removes the band being measured.
The one thing that does *not* matter is capsule size: Annex A notes there is
no practical limit on the microphone's dimensions, because directional effects
are negligible at infrasonic wavelengths.

Two actions follow. **Document the chain's own low-frequency corner** and
report $L_{p\mathrm{G}}$ only down to where the chain is flat; a level quoted to 0.25 Hz
from a chain that is 12 dB down at 0.5 Hz is not a measurement. **Choose an
averaging time long enough for the value to be representative**: Annex A.5
gives an integration time or time constant of 10 s as the usual choice, 1 s
when the upper part of the 1 Hz to 20 Hz band mainly contributes, and for
fluctuating noise a rectangular window of at least 1 min, whose result is
reported as the equivalent G-weighted sound pressure level. That is an order of
magnitude longer than the 125 ms readers bring from the Fast detector.

Outdoors there is a third problem, and below 20 Hz it is usually the largest:
the wind on the diaphragm generates more infrasound than the source. The
microphone therefore sits at the centre of a hard board on the ground, inside a
primary foam windscreen, with a secondary hemispherical screen added in wind
and its insertion loss documented and corrected.

![The infrasound measurement chain: a section view of a measurement capsule flush at the centre of a hard ground board with a callout on its static-pressure equalisation vent and the first-order corner that vent imposes, a primary foam windscreen over it and a secondary hemispherical screen around that, then the electrical chain as three boxes, a preamplifier whose corner is far below 0.25 Hz, a recorder with its low-cut switch off, and the G weighting followed by an integrator of at least 10 seconds; on the right an inset response plot from 0.1 Hz to 1 kHz showing the ISO 7196 G curve with its 0.25 to 315 Hz span shaded and the chain's own high-pass corner dashed across it, the overlap annotated as the usable band](https://docs.jmrp.io/phonometry/media/diagram_infrasound_chain.svg)

What has to be recorded for the result to be reportable is short: the chain's
own low-frequency corner, the board and the screens with their corrections, the
averaging time and window shape, and the $L_{p\mathrm{G}}$ with the analysis bandwidth
it was computed over.

## 2. Historical and special-purpose curves: B, D and AU

Three more curves complete the family. All three work in the audible range,
so they share one chart, drawn against the A curve because that is what each
of them is defined or described against: B as the curve between A and C, D as
the one with a hump A does not have, AU as A itself with a low-pass added.

![B, D and AU weighting curves measured at 96 kHz against a wide grey A-weighting reference, with the +11.5 dB D hump at 3.15 kHz and the AU cutoff 13 dB below A at 16 kHz annotated](https://docs.jmrp.io/phonometry/media/special_weighting_responses.svg)

*The three curves against the A reference (wide grey), measured at 96 kHz so
the axis reaches the 40 kHz where IEC 61012 still specifies the U low-pass.
B (green, dashed) discards less bass than A; D (purple) carries the +11.5 dB
hump at 3.15 kHz where jet turbomachinery whine annoys most; AU (orange) runs
inside the A reference up to 10 kHz and then falls away with U, reaching 13 dB
below A at 16 kHz. The infrasound G curve keeps its own chart in section 1,
and A, C and Z are in
[Frequency Weighting](https://docs.jmrp.io/phonometry/signals/levels/weighting/).*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import filters

# Measure each curve's response: weight a centered unit impulse and take its
# spectrum. 96 kHz, not 48 kHz: it reaches the 40 kHz top row of the
# IEC 61012 U-weighting table, which is the whole point of AU.
fs = 96000
impulse = np.zeros(fs)
impulse[fs // 2] = 1.0
freqs = np.fft.rfftfreq(fs, 1 / fs)

fig, ax = plt.subplots(figsize=(9, 5))
# A goes first and wide, as the reference the other three are read against.
for curve, width in (("A", 4.0), ("B", 1.8), ("D", 1.8), ("AU", 1.8)):
    spectrum = np.fft.rfft(filters.weighting_filter(impulse, fs, weighting=curve))
    ax.semilogx(freqs[1:], 20 * np.log10(np.abs(spectrum[1:]) + np.finfo(float).eps),
                label=curve, linewidth=width)
ax.set(xlim=(10, 40000), ylim=(-90, 18),
       xlabel="Frequency [Hz]", ylabel="Response [dB]")
ax.grid(True, which="both", alpha=0.3)
ax.legend()
plt.show()
```

### B (ANSI S1.4-1983, historical)

The middle curve of the original A/B/C level-switching scheme, drawn from
the ~70-phon equal-loudness contour. Analytically it is the C weighting with
one more zero at the origin and one extra real pole at
$f_5 = 158.49\ \text{Hz}$ (Appendix C of ANSI S1.4-1983), so it discards
less bass than A and more than C. It was dropped when IEC 61672-1 replaced
the older sound-level-meter standards; use it only to reproduce historical
data and measurements taken under older national codes (some legacy
automotive test procedures reported dB(B)). The implementation follows the
ANSI S1.4-1983 Appendix C constants and is pinned in CI against the Table IV
response values, within the strictest Table V mask (Type 0).

### D (IEC 537, withdrawn: aircraft noise)

The D weighting approximated the *perceived noisiness* contours used by the
perceived-noise-level (PNL) rating, so a plain sound level meter could
estimate aircraft noise: the +11.5 dB hump around 3.15 kHz is where jet
turbomachinery whine annoys most (it is deliberately *not* an equal-loudness
feature). NASA's aircraft-noise handbook gives the classic rule of thumb
$L_\mathrm{PN} \approx L_\mathrm{D} + 7\ \text{dB}$. IEC 537 was withdrawn and current
certification practice reports EPNL from one-third-octave analysis or plain
A-weighted levels, so `D` is provided for historical data and comparisons.
With the standard unavailable, the implementation uses the widely published
IEC 537 rational transfer function and is cross-checked against two
independent implementations (SQAT's zeros/poles and librosa's closed form,
which agree within 0.002 dB) and pinned in CI against the IEC 537 table
republished in NASA CR-3406.

```python
import numpy as np
from phonometry import filters, signals

# A 3.15 kHz whine sits right on the D-weighting hump: D rates it
# 10 dB *louder* than A does.
fs = 96000
t = np.arange(fs) / fs
whine = 0.1 * np.sin(2 * np.pi * 3150 * t)

ld = signals.leq(filters.weighting_filter(whine, fs, weighting="D"))
la = signals.leq(filters.weighting_filter(whine, fs, weighting="A"))
print(f"LD = {ld:.1f} dB   LA = {la:.1f} dB")
# LD = 82.5 dB   LA = 72.2 dB
```

### AU (IEC 61012, current: audible sound in the presence of ultrasound)

The only one of the three still in force. `AU` is the A weighting cascaded
with the **U** low-pass filter of IEC 61012:1990 (six poles, Table 2): flat
relative to A up to 10 kHz, then a steep cutoff (-13 dB at 16 kHz, -61.8 dB
at 40 kHz for U alone). Use it when strong ultrasonic components (ultrasonic
cleaners and welders, rodent repellers, some public-space deterrents) would
otherwise leak into an A-weighted reading through the meter's imperfect
high-frequency roll-off and overstate the *audible* exposure:

```python
import numpy as np
from phonometry import filters, signals

# 1 kHz tone (audible) buried under a strong 25 kHz ultrasonic component.
fs = 96000
t = np.arange(fs) / fs
audible = 0.1 * np.sin(2 * np.pi * 1000 * t)
x = audible + 1.0 * np.sin(2 * np.pi * 25000 * t)

la = signals.leq(filters.weighting_filter(x, fs, weighting="A"))
lau = signals.leq(filters.weighting_filter(x, fs, weighting="AU"))
la_ref = signals.leq(filters.weighting_filter(audible, fs, weighting="A"))
print(f"LA = {la:.1f} dB   LAU = {lau:.1f} dB   audible alone = {la_ref:.1f} dB")
# LA = 79.3 dB   LAU = 71.0 dB   audible alone = 71.0 dB
print(f"the ultrasound inflates LA by {la - la_ref:.1f} dB")
# the ultrasound inflates LA by 8.4 dB; AU recovers the audible level
```

Ultrasound only reaches a digital filter when the sample rate captures it,
so measure at 96 kHz or more (at 48 kHz there is nothing above 24 kHz to
reject); the AU design is fitted over the whole 10 Hz to 40 kHz range of
IEC 61012 Table 1, which keeps the
steep U roll-off accurate. Levels are reported as $L_\mathrm{AU}$. The
implementation follows the Table 2 pole locations exactly (they reproduce
every Table 1 nominal value within 0.05 dB) and is verified in CI against
the Table 1 tolerances up to 40 kHz.

The sample rate is only the second requirement. The first is the microphone,
and the arithmetic above holds only if the capsule and the interface really
delivered the 25 kHz component with a known response. IEC 61012's Introduction
puts the problem plainly: a meter whose response happens to extend to the
operating frequency of the ultrasonic equipment gives *inflated* readings of
the audible part, which is what U exists to prevent, and where the ultrasonic
component itself has to be quantified, the same Introduction calls for a
microphone system known to have a frequency response extending at least to that
operating frequency. In practice that means a 1/4 inch or 1/8 inch capsule
rather than the 1/2 inch capsule used for audible work: a 1/2 inch capsule is
already rolling off and strongly directional above 20 kHz, so it, and not the U
filter, would decide the reading. Check the converter too: an interface that
runs at 96 kHz but anti-alias filters at 20 kHz measures nothing to reject. And
because the near field of a cleaner or a welder changes by several decibels
over a few centimetres, take the reading at the operator's head position and
record it. Report $L_\mathrm{AU}$ together with the unweighted level of the ultrasonic
component and the capsule type: separating those two is the entire point of the
AU weighting.

## 3. Class verification: B and AU yes, G and D no

Only two of the four curves on this page can return a class verdict, because
only two have published tolerance tables. The `verify_weighting_class` verifier, described in section 6 of
[Frequency Weighting](https://docs.jmrp.io/phonometry/signals/levels/weighting/), also covers the curves
of this guide that have published tolerance tables. For `B` it uses
ANSI S1.4-1983 (Table IV design goals, Table V
limits) and the "class" verdicts read as the standard's instrument **Types**
1 and 2, or with `edition="1979"`, the IEC 651:1979 Table V limits, whose
footnote makes one mask govern every weighting characteristic and which add
the laboratory-grade Type 0 (the two Type 0 columns are *not* the same mask:
ANSI is two-sided and stricter at 10/12.5/16 Hz where IEC 651 is upper-only).
For `AU` it uses IEC 61012:1990 Table 1 (nominal A + nominal U with
the separate-unit tolerances, zero at the 1 kHz reference); IEC 61012
publishes a single tolerance set, so both margin slots agree and the verdict
is simply complies (1) or not (`None`); note that checking the rows above
20 kHz needs `fs` ≥ 96 kHz (below that they are dropped and the verdict is
`range_limited`). `G` and `D` are rejected: ISO 7196 defines one ±1 dB
tolerance with no class structure, and the withdrawn IEC 537 left no
tolerance table behind (both curves are pinned numerically in the CI
conformance report instead).

## What this guide covers

- **Covered.** ISO 7196:1995 for the G curve (Table 1 pole/zero values, verified against
  every Table 2 nominal response). ANSI S1.4-1983 for the historical B curve
  (Appendix C definition, Table IV design goals, Table V tolerance limits). IEC
  61012:1990 for AU (the U low-pass of Table 2 cascaded with A, verified against
  Table 1). IEC 537:1976 for the withdrawn aircraft-noise D curve, implemented
  from its published transfer function and cross-checked against two independent
  implementations.

- **Not covered.** `verify_weighting_class` does not produce a class verdict for G or D: ISO 7196
  defines a single ±1 dB tolerance with no class structure, and the withdrawn
  IEC 537 left no tolerance table behind. Both curves are pinned numerically
  against their published tables in the CI conformance report instead, not
  through this public verifier. B and D are provided for historical data and
  older national codes only; neither is current practice (IEC 61672-1 replaced
  B, and aircraft-noise certification now reports EPNL or plain A-weighted
  levels instead of D).

## See also

- [Frequency Weighting](https://docs.jmrp.io/phonometry/signals/levels/weighting/): the A, C and Z
  curves, the `high_accuracy` design and the IEC 61672-1 Table 3 class
  verification these curves build on.
- API reference: [`filters.weighting`](https://docs.jmrp.io/phonometry/reference/api/filters/weighting/) and [`filters.compliance`](https://docs.jmrp.io/phonometry/reference/api/filters/compliance/).
- Theory: [G-weighting (ISO 7196)](https://docs.jmrp.io/phonometry/reference/theory/signal-analysis/#g-weighting-iso-7196): the G curve of ISO 7196 and where its normalisation comes from.

## Quick answers

### Which weighting should I use for infrasound below 20 Hz?

Use the G frequency weighting of ISO 7196:1995, which rates infrasound the way A-weighting rates audible noise. Normalized to 0 dB at 10 Hz, it rises at 12 dB/octave between about 1 Hz and 20 Hz, falls at 24 dB/octave above 20 Hz and rolls off again at 24 dB/octave below about 1 Hz. Apply it to sources such as wind turbines, HVAC and blasting, and report levels as $L_{p\mathrm{G}}$ (or $L_\mathrm{Geq}$ for the equivalent level over time). Read the result against the ISO 7196 perception anchors, never against an A-weighted limit: about 100 dB(G) is the normal threshold, below about 90 dB(G) infrasound is not normally significant, and a very loud infrasound is about 120 dB(G).

## References

- **American National Standards Institute. (1983).** [*Specification for sound level meters*](https://webstore.ansi.org/standards/asa/ansis11983r20064a1985) (ANSI S1.4-1983).
  The historical B weighting: Appendix C analytic definition (Formula C2), Table IV design goals and Table V tolerance limits checked by verify_weighting_class in section 3.
- **Bennett, R. L., & Pearsons, K. S. (1981).** [*Handbook of Aircraft Noise Metrics*](https://ntrs.nasa.gov/citations/19810013341) (NASA CR-3406). NASA.
  Republishes the IEC 537 D-weighting table (Table SLD-I) used to pin the D response in CI.
- **International Electrotechnical Commission. (1976).** *Frequency weighting for the measurement of aircraft noise (D-weighting)* (IEC 537:1976 (withdrawn)).
  The D weighting, implemented from its published rational transfer function and cross-checked against two independent implementations and the tabulated curve republished in NASA CR-3406 (Table SLD-I).
- **International Electrotechnical Commission. (1990).** [*Filters for the measurement of audible sound in the presence of ultrasound*](https://webstore.iec.ch/en/publication/4296) (IEC 61012:1990).
  The AU weighting: U-weighting pole locations (Table 2), nominal responses and tolerances (Table 1) and the combined AU definition of subclause 2.2.
- **International Organization for Standardization. (1995).** [*Acoustics — Frequency-weighting characteristic for infrasound measurements*](https://www.iso.org/standard/13813.html) (ISO 7196:1995).
  The G-weighting pole/zero definition (Table 1), verified against every Table 2 nominal response value (0.25 Hz to 315 Hz).
