# Multichannel and Performance

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/signals/filters/multichannel/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/signals/filters/multichannel/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-05
Updated: 2026-10-27T01:37:22Z
Standards: IEC 61260-1:2014; IEC 61672-1:2013
Verified: 69 conformance checks (IEC 61260-1:2014; IEC 61672-1:2013) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Per-channel processing of multichannel recordings: the (channels, samples) convention, calibrating an array capsule by capsule, and where the time goes.

---

Most real measurement sessions produce more than one channel: the two ears
of a dummy head, the microphone pair of an intensity probe, the several
positions of a room survey, the capsules of a beamforming array. The
convention for all of them is one array of shape `(channels, samples)`
processed in a single call: every function runs along the last (time) axis
and preserves the leading channel axis, so each row is analyzed exactly as
if it were the only one.

That per-channel guarantee is normative, not just convenient. The band
filters applied to each row are the IEC 61260-1 designs and the weightings
and detector ballistics are the IEC 61672-1 ones, unchanged from the
single-channel path; the vectorization batches the arithmetic across rows
(one filter design, one SciPy call) and never mixes them. This is the
textbook procedure for multiple data records (Bendat & Piersol 2010,
§10.4.2): analyze each record individually first, and compute anything
joint as a separate, explicit step.

Use this page when your channels are parallel recordings on the same clock
and you want per-channel spectra or levels. When the question is *between*
channels (what is the delay from A to B, how much of B is explained by A),
that is cross-channel analysis: see
[Correlation and delay](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/) and
[Multiple and partial coherence](https://docs.jmrp.io/phonometry/signals/spectra/miso-coherence/), the
implementations of the Bendat & Piersol cross-correlation and
multiple-input models.

## A stereo analysis in one call

![Stereo analysis: pink noise and logarithmic sweep resolved per channel in one-third-octave bands](https://docs.jmrp.io/phonometry/media/signal_response_multichannel.svg)

*One `octave_filter` call, two channels: pink noise on the left, a logarithmic
sweep on the right. Both come back flat in one-third-octave bands, pink noise
because its $1/f$ spectrum has constant energy per fractional-octave band, the
sweep because it spends proportionally equal time in each, and neither row is
affected by the other.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy.signal import chirp
from phonometry import filters

# Stereo test signal: pink noise left, logarithmic sine sweep right
fs, duration = 48000, 5
t = np.linspace(0, duration, fs * duration, endpoint=False)
rng = np.random.default_rng(42)
spec = np.fft.rfft(rng.standard_normal(t.size))
spec[1:] /= np.sqrt(np.arange(1, spec.size))   # 1/f shaping: pink noise
left = np.fft.irfft(spec, t.size)
right = chirp(t, f0=50, t1=duration, f1=10000, method="logarithmic")

x = np.stack([left, right])                    # (2, n_samples)
filtered = filters.octave_filter(x, fs, fraction=3, limits=[20, 20000])
spl, freq = filtered.levels, filtered.frequencies

fig, axes = plt.subplots(2, 1, figsize=(9, 7), sharex=True)
for ax, levels, name in zip(axes, spl, ["Left: pink noise", "Right: log sweep"]):
    ax.semilogx(freq, levels, marker="o", label=name)
    ax.set_ylabel("Level [dB]")
    ax.grid(True, which="both", alpha=0.3)
    ax.legend()
axes[-1].set_xlabel("Frequency [Hz]")
plt.show()
```

Read the figure row by row before moving on. The roll-offs at the two ends of
the right row are the sweep's own 50 Hz and 10 kHz limits, not a filter effect.
And two conclusions follow from the flatness. A flat fractional-octave spectrum
corresponds to a $1/f$ power spectral density, so *white* noise does not look
flat in this display: it rises at 3 dB per octave, because each band is 26 %
wider than the one below. And two signals with completely different time
structure (a stationary noise and a sweep that is at 50 Hz at one moment and
10 kHz five seconds later) map to the same spectrum, which is why the band
levels of this page answer "how much energy per band" and never "when". The
octave spectrogram of
[Integrated and Statistical Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) is the
tool that restores the time axis.

The convention is consistent across the whole library: time is always the
**last axis**. This applies to `octave_filter`, `OctaveFilterBank`,
`weighting_filter`, `time_weighting`, `leq`, `laeq`, `ln_levels` and
`spectrogram`.

```python
import numpy as np
from phonometry import filters

# Two calibrated channels in Pa so the guide runs standalone
fs = 48000
t = np.arange(fs) / fs
left = 0.2 * np.sin(2 * np.pi * 1000 * t)
right = 0.1 * np.sin(2 * np.pi * 500 * t)

stereo = np.stack([left, right])          # (2, n_samples)
filtered = filters.octave_filter(stereo, fs, fraction=3)
spl, freq = filtered.levels, filtered.frequencies
# spl has shape (2, n_bands): one row per channel
```

## Accepted shapes, at a glance

![Array-shape flow: a 1-D (samples,) input reduces to a scalar and a 2-D (channels, samples) input reduces to (channels,), because the operation runs along the last axis while the channel axis is preserved](https://docs.jmrp.io/phonometry/media/diagram_multichannel.svg)

| Input | Interpreted as | Typical output |
| :--- | :--- | :--- |
| `(n,)` 1D array | one channel | scalar level / `(bands,)` |
| `(ch, n)` 2D array | `ch` channels, `n` samples each | `(ch,)` levels / `(ch, bands)` |
| list of floats | one channel (converted) | as 1D |
| `(ch, n)` into `spectrogram` | multichannel STFT-style | `(ch, bands, frames)` |

Everything vectorizes across the leading channel axis: one filter design is
applied to all channels in a single SciPy call. Convention: **channels
first**, like most DSP code (`soundfile` returns `(n, ch)`: transpose with
`x.T`). What that buys, and what it does not, is the subject of
[Performance](#performance-vectorization-and-caching) below.

## Per-channel semantics

Multichannel processing is strictly per channel: nothing is ever mixed,
summed or averaged across the channel axis. Three consequences worth
spelling out:

- **Combining channels is your decision.** Levels come back one per
  channel. If you need an array-average level (for instance the
  position-averaged levels of the room-acoustics standards), combine
  energies yourself: `10 * np.log10(np.mean(10 ** (spl / 10), axis=0))`,
  never the arithmetic mean of the dB values (see
  [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) for why).
- **One calibration factor means one sensitivity.** The scalar factor
  (`calibration=LevelCalibration(factor=...)` on a filter bank,
  `calibration_factor=` on `leq`, `laeq`, `ln_levels`, `lc_peak` and `sel`)
  multiplies every channel, which is correct only if all channels share the
  same sensitivity. For an array of microphones with individual calibrations,
  scale the rows first, `x * factors[:, None]`, and leave the factor at its
  default 1.0.
- **Stateful classes keep one state per channel.** In block processing the
  state array matches the channel count and a change of channel count
  resets it; see [Block Processing](https://docs.jmrp.io/phonometry/signals/filters/block-processing/).

![Upper panel: five thin grey one-third-octave curves from five positions in one room, together with a thick blue energy average and a dashed red arithmetic average of the decibel values. Above about 400 Hz the five positions agree within a decibel and the two averages coincide; below it, in the modal region, the positions scatter by up to fifteen decibels and the dashed red average runs below the blue one. Lower panel: the difference between them per band, zero above 400 Hz and rising to a worst under-read of 3.8 dB at 40 Hz](https://docs.jmrp.io/phonometry/media/survey_channel_average.svg)

*The two lines of code, on a realistic survey. Where the positions agree the
two averages are the same number; where they disagree, the modal region,
which is exactly where a room survey has several positions in the first place
, the arithmetic mean of the decibels under-reads by up to 3.8 dB. The error
is never negative, so it does not wash out over more positions.*

**Show the code for this figure**

```python
# Five positions of one room, band levels as a (5, bands) array. Here the
# positions are synthesized; in the field they are five rows of one capture.
rng = np.random.default_rng(7)
survey = np.stack([0.02 * (1 + 0.3 * rng.standard_normal())
                   * rng.standard_normal(2 * fs) for _ in range(5)])
survey_levels = filters.octave_filter(survey, fs, fraction=3).levels

energetic = 10 * np.log10(np.mean(10 ** (survey_levels / 10), axis=0))
arithmetic = np.mean(survey_levels, axis=0)
print(f"worst under-read {np.max(energetic - arithmetic):.2f} dB")
# worst under-read 2.12 dB
```

### Calibrating an array

The sensitivity vector in the bullet above is not arithmetic, it is a
procedure, and three things decide whether the result is right.

```python
# One sensitivity per capsule, in Pa per digital unit. Each element comes from
# metrology.sensitivity(cal_tone[i], target_spl=94.0, fs=fs) on a calibration
# capture in which the calibrator was coupled to capsule i and nothing else
# was touched.
factors = np.array([0.01021, 0.00984, 0.01007, 0.00998])
survey = np.stack([left, right, left, right])      # your (4, n) capture
calibrated = survey * factors[:, None]
filtered = filters.octave_filter(calibrated, fs, fraction=3)
spl, freq = filtered.levels, filtered.frequencies
```

**Lock the gains before the first tone and do not touch them again**, because
every factor is only valid for the gain it was measured at. **Couple the
calibrator to each capsule in turn** rather than reusing one factor for the
array: capsules of the same model differ by a few tenths of a decibel, and that
difference lands directly in a position-averaged level. **Repeat the pass at
the end of the session** and treat the largest per-channel difference as the
array's drift bound. Then two invariants that no downstream check can recover
if they are wrong: every channel must come from **one converter clock** (two
interfaces are two clocks, and a slow relative drift destroys any
between-channel analysis), and the **row-to-position map must be written down
at capture time**, because a swapped pair produces perfectly valid levels
attributed to the wrong positions.

![A four-microphone array capture. On the left, four measurement microphones on tripods at room-survey spacing, labelled P1 to P4 with their capsules at 1.2 m above the floor and each stamped with its own sensitivity in millivolts per pascal; a sound calibrator is drawn coupled onto the P2 capsule with a dashed arrow showing it moved from capsule to capsule. In the middle, one four-channel preamplifier and one interface with a highlighted bar spanning all four inputs reading single sample clock, fs equals 48 kHz, and beside it a crossed-out second interface labelled two interfaces equals two clocks, not one array. On the right, the array x drawn as four stacked rows labelled ch0 equals P1 through ch3 equals P4 with the shape (4, N). A footer repeats the three invariants: one clock, locked gains, recorded row-to-position map](https://docs.jmrp.io/phonometry/media/diagram_multichannel_capture.svg)

The shape table above is the abstraction of that picture: each row of `x` is
one microphone, and the mapping from a row index back to a position on the
floor exists only in your notes.

## Performance: Vectorization and caching

Start with what batching does *not* buy. The arithmetic scales linearly with
channels, because each channel has to be filtered by each band, so eight
channels cost eight channels however the call is written. Measured at 48 kHz
on 5 s per channel through one reused one-third-octave bank:

| Channels | One call [ms] | Per-channel loop [ms] | Ratio |
| ---: | ---: | ---: | ---: |
| 1 | 193 | 173 | 0.90 |
| 2 | 337 | 352 | 1.04 |
| 8 | 1394 | 1721 | 1.23 |
| 32 | 5646 | 5208 | 0.92 |

The ratio hovers around one, which is the honest answer: what batching removes
is per-call Python overhead and the temptation to redesign the bank, and it is
the redesign that actually costs: building a fresh one-third-octave bank takes
about 33 ms, an order of magnitude more than a single band-filtering pass over
a short frame.

So the cost model is simple. One SOS filtering pass per band per channel
dominates, which means the time scales with the number of bands (a
one-third-octave bank is three times a one-octave one), with the record length
and with the channel count, and nothing else. The actionable rules that
follow: **build one `OctaveFilterBank` and reuse it**; pass all channels in one
array for clarity rather than for speed; and when a run is too slow, reach for
`fraction`, `limits` and record length, because those are the three terms in
the model.

`OctaveFilterBank` is the tool for repeated or streaming analysis: one bank
designs its filters once and applies them to every frame, and NumPy
broadcasting covers all channels of a frame in one filtering call per band,
with no Python loop over channels.

```python
import numpy as np
from phonometry import filters

# Two calibrated channels in Pa so the guide runs standalone
fs = 48000
t = np.arange(fs) / fs
left = 0.2 * np.sin(2 * np.pi * 1000 * t)
right = 0.1 * np.sin(2 * np.pi * 500 * t)
stereo = np.stack([left, right])          # (2, n_samples)

bank = filters.OctaveFilterBank(
    fs=48000, fraction=3, design=filters.FilterDesign(filter_type='butter'))

# Access computed properties
# bank.frequencies (center), bank.lower_edges (lower), bank.upper_edges (upper), bank.sos (coefficients)

# Process multiple signals efficiently
stream = [stereo]                 # your sequence of multichannel frames
for frame in stream:
    # detrend=True (default) removes DC offset to improve low-freq accuracy
    filtered = bank.filter(frame, detrend=True)
    spl, freq = filtered.levels, filtered.frequencies
```

Additional performance notes:

- **Design cache**: `octave_filter()` reuses filter bank designs across calls
  with identical parameters (LRU cache, 32 entries), so calling it in a loop
  does not redesign the bank each time. `OctaveFilterBank` gives you explicit
  control over the design lifetime.
- **Multirate decimation**: low-frequency bands are filtered at a decimated
  rate, which is both faster and numerically more stable (see
  [Theory](https://docs.jmrp.io/phonometry/reference/theory/signal-analysis/)).
- **Optional numba**: the `impulse` time weighting kernel is JIT-compiled when
  numba is installed (`pip install "phonometry[perf]"`).

## What this guide covers

- **Covered.** IEC 61260-1:2014 and IEC 61672-1:2013 as far as they constrain each row of a
  `(channels, samples)` array: the band filters, weightings and detector
  ballistics applied per channel are the unchanged single-channel designs, and
  multichannel support adds no normative content of its own. The convention
  itself follows Bendat & Piersol's procedure for multiple data records (Section
  10.4.2): analyze each record individually first, and treat anything joint as a
  separate, explicit step.

- **Not covered.** Cross-channel questions, such as the delay between two channels or how much of
  one channel a second one explains, are deliberately left out: `octave_filter`,
  `weighting_filter` and `time_weighting` never mix or combine rows. See
  [Correlation and delay](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/) and
  [Multiple and partial coherence](https://docs.jmrp.io/phonometry/signals/spectra/miso-coherence/)
  for the cross-channel tools built on Bendat & Piersol's cross-correlation and
  multiple-input models.

## See also

- [Correlation and delay](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/): the cross-channel time-domain questions (delay, alignment) the per-channel path deliberately leaves to you.
- [Multiple and partial coherence](https://docs.jmrp.io/phonometry/signals/spectra/miso-coherence/): which of several correlated channels actually drives a response (Bendat & Piersol Ch. 7).
- [Block Processing](https://docs.jmrp.io/phonometry/signals/filters/block-processing/): the streaming counterpart, with one filter state per channel.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): the per-channel level metrics, and why dB values are combined energetically.
- API reference: [`phonometry`](https://docs.jmrp.io/phonometry/reference/api/filters/phonometry/) and [`filters.core`](https://docs.jmrp.io/phonometry/reference/api/filters/core/).

## References

- **Bendat, J. S., & Piersol, A. G. (2010).** *Random data: Analysis and measurement procedures* (4th ed.). Wiley. https://doi.org/10.1002/9781118032428
  Section 10.4.2 (the procedure for analyzing multiple data records: individual per-record analysis first, joint cross-record analysis as a separate, deliberate step) and Chapter 7 (the multiple-input/output models that joint step leads to). ISBN 978-0-470-24877-5.
- **International Electrotechnical Commission. (2013).** [*Electroacoustics — Sound level meters — Part 1: Specifications*](https://webstore.iec.ch/en/publication/5708) (IEC 61672-1:2013).
  The weighting and time-integration semantics applied per channel, exactly as the single-channel standard prescribes.
- **International Electrotechnical Commission. (2014).** [*Electroacoustics — Octave-band and fractional-octave-band filters — Part 1: Specifications*](https://webstore.iec.ch/en/publication/5063) (IEC 61260-1:2014).
  The band definitions each channel is filtered with; the multichannel path batches them unchanged. Multichannel support adds no normative content of its own: each channel is filtered exactly as the single-channel standard prescribes, and the vectorization only batches the computation across the channel axis.