# Octave and Fractional-Octave Filter Banks

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/signals/filters/filter-banks/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/signals/filters/filter-banks/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-05
Updated: 2026-11-16T21:36:13Z
Standards: IEC 61260-1:2014; ANSI S1.11-2004; ISO 266:1997
Verified: 20 conformance checks (IEC 61260-1:2014; ANSI S1.11-2004) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Octave and fractional-octave band levels in Python: band mathematics, the octave_filter parameters, the parametric EQ, band signals and zero-phase filtering.

---

phonometry supports several filter types, each with its own transfer function
characteristic. Butterworth, Chebyshev II and Bessel place their **−3 dB points
on the ANSI S1.11 band edges**, so their band levels are directly comparable.
The two equiripple designs (Chebyshev I, Elliptic) do not: they take those edges
as the *ripple* edge instead, which widens the band and biases every band level
by a fixed few tenths of a decibel: see section 1, because the bias is
systematic and does not average out.

By the end of this page you can design a bank for any $1/b$ fraction, read
every argument off one table, cascade RBJ EQ sections, pull out per-band time
signals and filter with zero phase. Section 1 is the mathematics the design
rests on; if you only want to call the function, start at section 3. How the
five architectures differ is
[Filter Architecture Gallery](https://docs.jmrp.io/phonometry/signals/filters/filter-gallery/), and
what "class 1" means for the result is
[Filter Class Verification](https://docs.jmrp.io/phonometry/signals/filters/filter-compliance/).

## How do I compute octave or one-third-octave band levels in Python?

`result = filters.octave_filter(x, fs, fraction=3)` filters a signal `x`
sampled at `fs` hertz into one-third-octave bands (`fraction=1` gives octaves):
`result.levels` holds the level of each band in decibels and
`result.frequencies` the exact mid-band frequency of each.
[Section 2](#2-what-a-call-gives-back) calls it on a 1 kHz tone over noise
and draws the spectrum the result holds.

## 1. Fractional octave bands: the math

IEC 61260-1:2014 builds every band from the base-10 octave ratio
$G = 10^{3/10} \approx 1.99526$ (so "one octave" is *not* exactly 2). For
band fraction $1/b$, the mid frequencies and band edges follow (5.2-5.6):

$$
f_\mathrm{m} = 1000 \cdot G^{x/b}\ (b\ \text{odd}), \qquad
f_\mathrm{m} = 1000 \cdot G^{(2x+1)/2b}\ (b\ \text{even}), \qquad
f_1 = f_\mathrm{m} G^{-1/2b}, \quad f_2 = f_\mathrm{m} G^{+1/2b}
$$

so every 1/3-octave band spans $G^{1/3} \approx 1.2589 \approx 10^{1/10}$:
ten bands per decade, which is why the nominal frequencies (25, 31.5, 40 …)
repeat scaled by 10. phonometry designs each band as an SOS cascade on those
edges, but where the −3 dB point ends up depends on what the architecture means
by its design frequency, and only three of the five put it on $f_1$ and $f_2$.

The two forms exist so that the reference frequency 1000 Hz is a band **mid**
frequency when $b$ is odd and a band **edge** when $b$ is even (5.4, NOTE 2).
Either way the edges of the octave bands are edges of every fraction, so an
octave band is exactly two half-octave bands or three one-third-octave bands;
the edge formulas are the same in both cases.

![Three octaves about 1 kHz, from 354.8 Hz to 2818.4 Hz on a logarithmic frequency axis, cut into four rows of bands, each band carrying its exact mid-band frequency and, in bold, its label. Octave, b = 1: three bands centred on 501.2, 1000.0 and 1995.3 Hz, labelled 500, 1k and 2k. Half octave, b = 2: six bands, the two that meet at 1 kHz centred on 841.4 and 1188.5 Hz and labelled 841 and 1.19k. One-third octave, b = 3: nine bands from 398.1 to 2511.9 Hz, the middle one centred on 1000.0 Hz and the next one, 1258.9 Hz, labelled 1.25k. One-sixth octave, b = 6: eighteen bands, the two that meet at 1 kHz centred on 944.1 and 1059.3 Hz and labelled 940 and 1.06k. A dashed line marks the reference frequency of 1 kHz: it meets a mid-band frequency in the two rows of odd b and runs along a band edge in the two rows of even b, where no band is centred on it](https://docs.jmrp.io/phonometry/media/fractional_octave_band_ruler.svg)

The practical consequence is easy to trip over: a spectrum of an even fraction
(`fraction=2`, `6`, `12` or `24`) has no 1 kHz band at all, and comparing it
band by band against a one-third-octave table is meaningless. Its labels are
not preferred frequencies either. Only the octave and one-third-octave labels
are the nominal frequencies of Table E.1, which are the ISO 266 series. A
half-octave label is the exact centre rounded to three significant digits
(Annex E.2), and from 1/4 to 1/24 octave the label keeps three digits when the
leading digit is 1 to 4 and two when it is 5 to 9 (Annex E.3), which is how the
band centred on 1059.3 Hz comes to be labelled `1.06k`. Finer than 1/24 octave,
E.3.5 adds significant digits until no label repeats within a decade: one more
at 1/48 octave.

### Where each architecture's −3 dB point actually lands

Butterworth's SciPy design frequency *is* its −3 dB point, so it needs no
correction. Chebyshev II is designed through its stopband edges, mapped back
from the band edges analytically, and Bessel is normalized with `norm="mag"`
rather than SciPy's default phase normalization; both corrections exist so that
their −3 dB points land on the edges too. Chebyshev I and Elliptic are handed
the band edges directly, and for those two families SciPy reads them as the
*equiripple passband* edge: the response there is the ripple depth, not −3 dB.
Measured on the 1 kHz octave band at 48 kHz with order 6 and the default
`ripple=0.1`:

| Architecture | Response at $f_1$ and $f_2$ | Noise bandwidth / $(f_2 - f_1)$ | Band-level offset |
| :--- | :---: | :---: | :---: |
| `butter` | −3.01 dB | 1.003 | reference |
| `cheby2` | −3.01 dB | 1.003 | −0.02 dB |
| `bessel` | −3.01 dB | 0.971 | +0.05 dB |
| `cheby1` | **−0.10 dB** | 1.066 | **+0.33 dB** |
| `ellip` | **−0.10 dB** | 1.052 | **+0.25 dB** |

The first three columns are the 1 kHz octave band; the last is the median
band-level difference from Butterworth over a whole 1/3-octave bank analysing
20 s of white noise. That last column matters because it is a *bias*, not
scatter: it does not shrink with averaging time, it is larger than the whole
class 1 passband corridor (±0.4 dB), and it moves every band at once, so a
spectrum measured with `cheby1` sits bodily above one measured with `butter`.
Choose one architecture per campaign, and never mix architectures inside one
spectrum. Raising `order` shrinks the offset, because a narrower transition band
pulls the −3 dB point back toward the ripple edge; for `cheby1` the median goes
+0.76 dB at order 4, +0.33 dB at order 6, +0.16 dB at order 8 and +0.04 dB at
order 12. Lowering `design.ripple` does the opposite of what intuition suggests
and makes the offset *larger* (+0.62 dB at `ripple=0.02`), because at fixed
order a flatter passband buys a slower roll-off.

### Poles, zeros and stability

A digital band-pass filter is a constellation of poles and zeros in the
z-plane: zeros at or near DC and Nyquist pin the response down far from the
band (to the stopband floor, for equiripple designs), and the poles cluster
just inside the unit circle at the angles
$\omega = 2\pi f / f_\mathrm{s}$ the passband spans. Two intuitions follow. First,
selectivity is proximity: the closer the poles sit to the unit circle, the
sharper the band and the longer the filter rings (the group-delay peaks of
section 5 are that ringing, measured). Second, stability is a margin, not a
property of the architecture: an IIR filter is stable only while every pole
stays strictly inside the unit circle, and a narrow band at a high sample
rate pushes the poles outward (pole radius $\approx 1 - \pi B / f_\mathrm{s}$ for
bandwidth $B$) and squeezes them together, until double-precision
coefficients can no longer represent their positions accurately.
Second-order sections (SOS) defuse half of the problem: each pole pair keeps
its own coefficients, so rounding errors stay local instead of compounding
through one high-order polynomial. The other half, the tiny $B / f_\mathrm{s}$ ratio
itself, is what decimation fixes.

![Three panels for the 25 Hz one-third-octave band of a bank at 48 kHz. Left, the z-plane constellation of the band designed at the full rate: every pole is collapsed onto z = 1, with a zoom inset showing the six poles spread over less than a thousandth of the radius and the annotation 1 minus r equals 8.7e-05. Middle, the same band as the bank actually realizes it, at 906 Hz after decimating by 53: the poles have left z = 1 and sit just inside the unit circle in two tight groups about 10 degrees above and below the real axis, at 1 minus r equals 4.6e-03. Right, the largest pole radius of every band of the bank on log-log axes, the one-rate design rising steadily from 4e-05 at 12.5 Hz to 5e-02 at 16 kHz, while the multirate bank stays between 3.5e-03 and 4.6e-03 from 12.5 Hz to 630 Hz and, from 800 Hz up, where its bands run at the full rate, follows the one-rate curve](https://docs.jmrp.io/phonometry/media/pole_migration.svg)

*Selectivity is proximity, and the price is conditioning. At the full rate the
25 Hz band's poles sit less than $10^{-4}$ from the unit circle and on top of
each other; the same band realized at its decimated rate has them spread apart
and 53 times further away. The right panel is the design decision as one
curve: the multirate bank holds every decimated band at the same distance from
the unit circle, whatever its centre frequency, and the bands that run at the
full rate, from 800 Hz up, sit about as far from it or further.*

**How this figure was measured**

Both banks come from the parameter table of section 3, one with the default
`design` and one with `design=FilterDesign(resample=False)`. The pole positions
are read straight off the bank: `bank.sos[idx]` is the SOS cascade of band
`idx` and `scipy.signal.sos2zpk` turns it into zeros, poles and gain, so the
distance from the unit circle is `1 - abs(poles).max()`. For the 25.1 Hz band
of a 48 kHz one-third-octave bank that distance is **8.73e-05** at the full
rate and **4.62e-03** at the decimated rate the bank actually uses
(`bank.factor[idx]` is 53, the largest factor that keeps the band's processing
Nyquist frequency at least sixteen times its upper band edge, so the band runs
at 906 Hz). SciPy raises `BadCoefficients` while reading the full-rate design,
and not the decimated one: that warning is the argument of this section,
printed by the library that hit it.

### Multirate decimation

A 25 Hz one-third-octave band at 48 kHz spans about 5.8 Hz, 0.024 %
of Nyquist, with coefficients so stiff they go numerically unstable. The bank
avoids that by filtering low bands at a decimated rate:

![Multirate decimation: high bands filtered at the input rate, low bands after anti-alias low-pass and decimation so the SOS sections stay numerically healthy](https://docs.jmrp.io/phonometry/media/diagram_multirate.svg)

Decimating by $M$ rescales the problem: the same 5.8 Hz bandwidth becomes
$M$ times larger relative to the new Nyquist, the pole radius pulls away from
the unit circle, and the SOS coefficients return to a well-conditioned range.
The price is bookkeeping the bank pays internally: an anti-alias low-pass must
run before every decimation stage, because a component above the new Nyquist
that folds down lands *inside* the low bands being measured, and no later
filter can remove it. The bank's is a linear-phase Kaiser-windowed filter
sized for a 120 dB stopband, which keeps every image the decimation folds onto
a band more than 125 dB below it, and `verify_filter_class` grades those
images against Table 1 of IEC 61260.

### Aliasing pitfalls

The bank protects its own decimation stages, but it can only analyze what the
capture chain delivered:

- **Fold-down at the ADC.** Energy above $f_\mathrm{s}/2$ that reaches the converter
  without an analog anti-alias filter folds into the analysis range and is
  indistinguishable from real in-band sound. Sound cards filter this
  internally; custom instrumentation chains may not.
- **Cheap resampling.** Converting a 44.1 kHz recording to 48 kHz with a
  low-quality resampler leaves images that bias the highest bands. Use a
  polyphase resampler (`scipy.signal.resample_poly`) or, simpler, analyze at
  the native rate: every phonometry function takes `fs` directly.
- **Bands near Nyquist.** A band whose upper edge approaches $f_\mathrm{s}/2$ cannot
  realize its design response: the bilinear transform compresses the
  frequency axis there (the same warping the weighting filters cancel by
  fitting their prototype at the sample rate, which the bank does not do).
  Keep the top band edge comfortably below Nyquist or raise
  `fs`, and let `verify_filter_class` report how much margin is left.

### How long must the record be?

A band level is not read off a signal, it is *estimated* from it, and the
narrower the band the longer that takes. The bandwidth of a $1/b$-octave band
is $B = f_\mathrm{m}\,(G^{1/2b} - G^{-1/2b})$, which for one-third octaves is
$0.231\,f_\mathrm{m}$, and two consequences follow from it.

The filter has to **settle**: a band rings for a few times $1/B$, so that much
of the front of the record is transient rather than level and must be
discarded (about a second in the 12.5 Hz band, twelve milliseconds at 1 kHz).
And the estimate carries a **random error** of about $4.34/\sqrt{BT}$ dB on
noise-like sound, so a standard deviation of 0.4 dB needs $BT = 100$:

| Lowest band reported | $B$ [Hz] | $T$ for a 0.4 dB standard deviation |
| :--- | ---: | ---: |
| 12.5 Hz | 2.9 | 35 s |
| 125 Hz | 29 | 3.5 s |
| 1 kHz | 231 | 0.4 s |

The rule that follows is one line: **the lowest band you intend to report sets
the record length for the whole bank.** Analysing a 1 s clip down to 12.5 Hz
and reporting the result to one decimal is not a measurement of that band, and
neither `octave_filter` nor `OctaveFilterBank` warns you. The general
$1/\sqrt{BT}$ law is derived in
[Correlation, time delay and envelope](https://docs.jmrp.io/phonometry/signals/spectra/correlation-delay/);
the same arithmetic applied per frame instead of per record is the
`window_time` note of
[Integrated and Statistical Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/).

The band mathematics above is shared by every architecture. How the
architectures actually differ, the comparison at the −3 dB crossover, the
full 1/1 and 1/3 octave response gallery and the usage examples per
architecture, up to the Linkwitz-Riley crossover, is
[Filter Architecture Gallery](https://docs.jmrp.io/phonometry/signals/filters/filter-gallery/).

## 2. What a call gives back

Every call returns an `OctaveFilterResult`: the band `levels`, the
`frequencies` they sit on, and the per-band `bands` when the call asked for
them. The fields have names because the alternative was a tuple whose length
depended on a keyword, and a reader of `_, _, bands = ...` had to count commas
to find out what the first two were.

```python
import numpy as np
from phonometry import filters

fs = 48000
t = np.arange(fs) / fs
rng = np.random.default_rng(7)
noise = np.cumsum(rng.standard_normal(fs))
noise /= np.std(noise)
x = 0.4 * np.sin(2 * np.pi * 1000.0 * t) + 0.05 * noise

result = filters.octave_filter(x, fs, fraction=3, limits=[20.0, 20000.0])
print(len(result.frequencies), round(float(result.levels.max()), 1))
# 31 83.0
ax = result.plot()            # the spectrum below
```

![One-third-octave spectrum drawn by the result object itself: band level in decibels against band centre frequency on a log axis from 16 hertz to 20 kilohertz, with one marked point per band. A 1 kilohertz tone stands at 83 decibels, about forty decibels clear of a noise floor that runs near 43 decibels at the bottom of the range and falls steadily to 17 decibels at the top](https://docs.jmrp.io/phonometry/media/octave_band_levels.svg)

*The one-third-octave spectrum of a 1 kHz tone over noise. Any result in the
library redraws itself this way: `result.plot()` above produced exactly this
figure.*

Two accessors exist for the fields a call may not have filled.
`require_levels()` and `require_bands()` return the value or say what the call
would have had to ask for, which beats meeting a `None` several lines later:

```python
bands = filters.octave_filter(x, fs, sigbands=True).require_bands()
print(len(bands))
# 11

try:
    filters.octave_filter(x, fs).require_bands()
except ValueError as error:
    print(error)
# this result kept no band waveforms: call with sigbands=True to have them
```

## 3. `octave_filter()` / `OctaveFilterBank` parameters

The everyday arguments come first and positionally (`x`, `fs`, `fraction`,
`order`, `limits`), and everything else is grouped into four small frozen
dataclasses passed by keyword: `design` (`FilterDesign`), `calibration`
(`LevelCalibration`), `block_processing` (`BlockProcessing`) and
`response_plot` (`ResponsePlot`). Being frozen, they are hashable, which is
what lets equal option bundles hit the same design cache. The table below names
each option by the bundle it travels in.

Three call sites share this table, and they do not accept the same options, so
the **Where** column names the one each option belongs to: `octave_filter()` is
the one-shot function, `OctaveFilterBank(...)` is the constructor, and
`bank.filter()` is the per-call method.

| Parameter | Where | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- | :--- |
| `x` | function, `.filter()` | 1D or 2D array, or `Signal` | digital units, or Pa for a calibrated `Signal` | non-empty | 2D is `[channels, samples]`; a `dbfs` bank ignores the calibration and stays in digital units |
| `fs` | function, constructor | int | Hz | > 0; required by the constructor, and taken from the `Signal` by `octave_filter()` and `bank.filter()` | |
| `fraction` | function, constructor | int | — | default `1`; common `3`; any $b \ge 1$ | Bands per octave = $b$ |
| `order` | function, constructor | int | — | default `6` | SOS order per band |
| `limits` | function, constructor | list `[lo, hi]` | Hz | default `[12, 20000]`, trimmed to the bands $f_\mathrm{s}$ holds | Analysis range; limits past $f_\mathrm{s}/2$ lose their top bands with a `FilterBankWarning`, and a rate that holds none of the bands is refused |
| `design.filter_type` | function, constructor | str | — | `'butter'` (default), `'cheby1'`, `'cheby2'`, `'ellip'`, `'bessel'` | See the [Filter Architecture Gallery](https://docs.jmrp.io/phonometry/signals/filters/filter-gallery/) |
| `design.ripple` / `design.attenuation` | function, constructor | float | dB | `ripple` default `0.1`; `attenuation` default `72.0` | Passband ripple / stopband attenuation (cheby/ellip); `cheby2` needs `attenuation` $\ge 70$ for class 1, since scipy pins its equiripple floor at exactly this value |
| `design.resample` | function, constructor | bool | — | default `True` | Filter each band on a decimated rate (multirate) |
| `response_plot.show` | function, constructor | bool | — | default `False` | Plot the bank response (needs matplotlib) |
| `response_plot.file` | function, constructor | str or `None` | — | default `None` | Save the bank-response plot to this path |
| `calibration.factor` | function, constructor | float | — | default `1.0` | Scales the input to pascals (see the Calibration guide) |
| `calibration.dbfs` | function, constructor | bool | — | default `False` | Reference levels to digital full scale instead of 20 µPa |
| `block_processing.stateful` / `.steady_ic` | constructor only | bool | — | default `False` | Streaming state; see [Block Processing](https://docs.jmrp.io/phonometry/signals/filters/block-processing/) |
| `sigbands` | function, `.filter()` | bool | — | default `False` | Also return the per-band time signals |
| `mode` | function, `.filter()` | str | — | `'rms'` (default) or `'peak'` | Per-band statistic returned |
| `nominal` | function, `.filter()` | bool | — | default `False` | Return nominal band labels (e.g. `1000`) instead of exact centre frequencies |
| `detrend` | function, `.filter()` | bool | — | default `True` | Remove the input signal's DC offset once, before filtering (improves low-frequency accuracy) |
| `zero_phase` | `.filter()` only | bool | — | default `False` | Forward-backward filtering (offline); see section 6 |
| `calculate_level` | `.filter()` only | bool | — | default `True` | `False` returns the band signals without computing levels (use with `sigbands=True`) |

The split is not arbitrary: the one-shot `octave_filter()` designs a bank and
uses it once, so it carries the design-time options only. `zero_phase` and
`calculate_level` are decided per call and therefore live on
`OctaveFilterBank.filter()`, while `octave_filter(x, fs, zero_phase=True)` raises
`TypeError`. Streaming state is fixed when the bank is built.

`mode` has exactly two values. `'rms'` reports the energy-mean level of the band
over the whole record, which is what every standard means by "band level".
`'peak'` reports $20\log_{10}$ of the largest absolute sample inside the band,
against the same 20 µPa reference; it is an instantaneous band peak, not a
peak-hold reading, it is band-limited and unweighted so it is *not* the
C-weighted peak $L_\mathrm{Cpeak}$ of the
[Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) guide, and on impulsive signals it
is dominated by the filter's own ringing; it belongs to transient diagnostics,
not to level reporting. There is no `'sum'` mode: a total across bands is an
energy sum the caller performs, `10*np.log10(np.sum(10**(spl/10)))`, never an
arithmetic mean of decibels.

`verify_filter_class(bank)` checks the designed bank against the IEC 61260-1
Table 1 acceptance limits, the effective bandwidth and the summation of
adjacent outputs, and reports the class (`1`, `2` or `None` if outside both)
with per-band margins. The default octave and one-third-octave banks are
class 1 on all three, decimated or filtered at the full rate; Filter Class
Verification says why the decimation barely moves the summation.

### What `order` buys, and where it stops buying

`order` is the order of each band-pass section pair, so it sets how fast the
skirts fall away and therefore how much of a neighbouring band leaks into a
band level. Order 6 is the default because it clears the IEC 61260-1 mask with
room to spare for Butterworth, and the arithmetic is worth seeing: at 48 kHz on
a one-third-octave Butterworth bank, order 2 misses class 1 by 27.03 dB on the
far stopband, while orders 4, 6, 8 and 10 all pass the Table 1 mask with a
class 1 margin of exactly +0.40 dB.

That identical margin is not a coincidence and it is the useful half of the
rule. From order 4 upward the binding constraint has moved out of the stopband
and into the passband, where a maximally flat design sits at 0 dB deviation and
the class 1 corridor is ±0.4 dB; so raising the order further buys stopband
depth but no margin on the mask. What binds from there is the summation of
adjacent outputs, which IEC 61260-1:2014 grades too (5.16): order 4 misses
class 1 on it by 0.002 dB and is class 2 overall, while orders 6, 8 and 10
meet it by 0.04 dB, 0.08 dB and 0.07 dB. A higher order does cost: every
extra pole pair lengthens
the ringing (the group-delay peaks of section 5 grow with order), which is why
transient work and short-window spectrograms prefer low orders. The margin
arithmetic itself is
[Filter Class Verification](https://docs.jmrp.io/phonometry/signals/filters/filter-compliance/).

## 4. Parametric EQ (`ParametricEQ`)

Biquad equalizer sections per the **RBJ Audio EQ Cookbook**
(Bristow-Johnson): peaking (bell), low/high shelf, low/high-pass, band-pass
(constant 0 dB peak or constant skirt gain), notch and all-pass, each
parameterized by `fs`, `f0`, `gain_db` and one of `q`, `bw` (bandwidth in
octaves) or `slope` exactly as the cookbook defines them. Sections cascade
as a numerically robust SOS chain, and the design is closed-form exact: a
peaking section passes exactly `gain_db` at `f0` and exactly 0 dB at DC and
Nyquist, shelves land exactly on `gain_db` at their shelved end, and the
all-pass has unit magnitude everywhere (only the phase turns).

```python
import numpy as np
from phonometry import filters

fs = 48000
rng = np.random.default_rng(1)
x = rng.standard_normal(fs)                 # one second of noise

eq = filters.ParametricEQ(fs, [
    filters.EQSection(filter_type="lowshelf", f0=100.0, gain_db=4.0),
    filters.EQSection(filter_type="peaking", f0=1000.0, gain_db=-6.0, bw=1.0),  # one-octave cut
    filters.EQSection(filter_type="highshelf", f0=8000.0, gain_db=3.0),
])
y = eq.filter(x)              # apply the cascade
res = eq.response()           # frozen result carrying the SOS cascade
axes = res.plot()             # magnitude + phase of the cascade
```

For block processing pass `stateful=True` (the same convention as
`WeightingFilter`); the one-shot helper is `parametric_eq(x, fs, sections=...)`.

![Two stacked panels drawn by the result object itself. Above, the magnitude of the three-section cascade of the snippet: plus 4 dB below 100 Hz from the low shelf, a one-octave-wide minus 6 dB bell at 1 kHz, and plus 3 dB above 8 kHz from the high shelf, with each individual section drawn in light grey underneath the thick cascade line. Below, the phase of the same cascade in degrees, swinging about twenty degrees either side of zero around the shelf and bell frequencies](https://docs.jmrp.io/phonometry/media/parametric_eq_cascade.svg)

*The three sections of the snippet (grey) and the cascade they sum to; the
lower panel is the phase the magnitude costs. Any result in the library redraws
itself this way, `res.plot()` above produced exactly this figure.*

![Magnitude responses of the RBJ Audio EQ Cookbook biquad family: peaking, shelves, low/high-pass, band-pass and notch](https://docs.jmrp.io/phonometry/media/parametric_eq_family.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import filters

fs = 48000
family = [
    filters.EQSection(filter_type="peaking", f0=1000.0, gain_db=6.0, q=1.4),
    filters.EQSection(filter_type="lowshelf", f0=125.0, gain_db=6.0),
    filters.EQSection(filter_type="highshelf", f0=4000.0, gain_db=-6.0),
    filters.EQSection(filter_type="lowpass", f0=10000.0),
    filters.EQSection(filter_type="highpass", f0=50.0),
    filters.EQSection(filter_type="bandpass", f0=500.0, q=2.0),
    filters.EQSection(filter_type="notch", f0=2000.0, q=6.0),
]
fig, ax = plt.subplots(figsize=(10, 6))
for section in family:
    res = filters.ParametricEQ(fs, [section]).response(f_min=20.0, f_max=20000.0)
    ax.semilogx(res.frequencies, res.magnitude_db,
                label=f"{section.filter_type} @ {section.f0:g} Hz")
ax.set(xlim=(20, 20000), ylim=(-27, 9),
       xlabel="Frequency [Hz]", ylabel="Magnitude [dB]")
ax.grid(True, which="both", alpha=0.3)
ax.legend(loc="lower center", ncols=2, fontsize=9)
plt.show()
```

Everything above is design. Proving that a designed bank meets a
performance class of IEC 61260-1, band by band and with its margin in
decibels, is
[Filter Class Verification](https://docs.jmrp.io/phonometry/signals/filters/filter-compliance/): the
Table 1 acceptance mask, the stricter class 0 of the withdrawn 1995 edition,
what a class buys in a measurement, and the accredited compliance fiche.

## 5. Band signals and group delay

`sigbands=True` returns the per-band time signals alongside the levels, which
is what makes phase and transient behaviour visible, and what exposes the
group delay each architecture pays for its selectivity. Stability itself is
section 1's subject, under
[Poles, zeros and stability](#poles-zeros-and-stability); what this section
adds is the evidence, because a filter whose impulse response decays to zero is
a stable filter.

```python
import numpy as np
from phonometry import filters

# 1. Generate a signal (Sum of 250Hz and 1000Hz)
fs = 48000
t = np.linspace(0, 0.5, int(fs * 0.5), endpoint=False)
y = np.sin(2 * np.pi * 250 * t) + np.sin(2 * np.pi * 1000 * t)

# 2. Compare architectures (Butterworth vs Chebyshev II)
filtered = filters.octave_filter(
    y, fs=fs, fraction=1, sigbands=True,
    design=filters.FilterDesign(filter_type='butter'))
spl_b, freq, xb_butter = filtered.levels, filtered.frequencies, filtered.bands
filtered = filters.octave_filter(
    y, fs=fs, fraction=1, sigbands=True,
    design=filters.FilterDesign(filter_type='cheby2'))
spl_c2, xb_cheby2 = filtered.levels, filtered.bands

# 'xb_butter' and 'xb_cheby2' contain the time-domain signals per band
```

![Time-domain band decomposition comparing Butterworth and Chebyshev II, including the impulse response](https://docs.jmrp.io/phonometry/media/signal_decomposition.svg)

*The top panel is the input, the middle panels are its band signals under
**Butterworth** (solid) and **Chebyshev II** (dashed), and the bottom panel is
the impulse response of the 1 kHz band of each. Both impulse responses decay to
zero (that is the stability check) but the Chebyshev II ring lasts visibly
longer, which is the transient price of its steeper skirt.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import filters

fs = 48000
t = np.linspace(0, 0.5, int(fs * 0.5), endpoint=False)
y = np.sin(2 * np.pi * 250 * t) + np.sin(2 * np.pi * 1000 * t)

bank_b = filters.OctaveFilterBank(fs=fs, fraction=1, order=6, limits=[100.0, 2000.0])
bank_c = filters.OctaveFilterBank(fs=fs, fraction=1, order=6, limits=[100.0, 2000.0],
                          design=filters.FilterDesign(filter_type="cheby2"))
filtered = bank_b.filter(y, sigbands=True)
freq, xb_butter = filtered.frequencies, filtered.bands
xb_cheby2 = bank_c.filter(y, sigbands=True).bands

# The published figure has two extra panels: the input on top and, at the
# bottom, the 1 kHz band of a unit impulse through each bank.
impulse = np.zeros_like(t)
impulse[0] = 1.0
imp_butter = bank_b.filter(impulse, sigbands=True).bands
imp_cheby2 = bank_c.filter(impulse, sigbands=True).bands
one_k = int(np.argmin(np.abs(np.asarray(freq) - 1000.0)))

fig, axes = plt.subplots(len(freq) + 2, 1, figsize=(9, 2 * (len(freq) + 2)),
                         sharex=True)
axes[0].plot(t, y)
axes[0].set_title("Original signal (250 Hz + 1000 Hz)")
for ax, fc, xb, xc in zip(axes[1:-1], freq, xb_butter, xb_cheby2):
    ax.plot(t, xb, label="Butterworth")
    ax.plot(t, xc, "--", label="Chebyshev II")
    ax.set_title(f"{fc:.0f} Hz band")
axes[-1].plot(t, imp_butter[one_k], label="Butterworth")
axes[-1].plot(t, imp_cheby2[one_k], "--", label="Chebyshev II")
axes[-1].set_title("Impulse response, 1 kHz band")
axes[1].legend()
axes[0].set_xlim(0, 0.04)
axes[-1].set_xlabel("Time [s]")
plt.tight_layout()
plt.show()
```

**Note**

**Why do the signals look shifted in time?**
Digital IIR filters (like Butterworth or Chebyshev) have **non-linear phase
responses**, which results in frequency-dependent **Group Delay**. In the 250 Hz
band, you can see that the Chebyshev II filter has a different propagation delay
compared to the Butterworth filter. This is a normal physical property of these
architectures: more aggressive frequency roll-offs usually come at the cost of
higher group delay and phase distortion.

### Group delay, quantified

The group delay $\tau_\mathrm{g}(\omega) = -\frac{d\phi(\omega)}{d\omega}$ of the
1 kHz octave band shows the trade-off directly: Bessel stays nearly flat across
the passband (transient shapes survive), while Chebyshev I and Elliptic pay for
their steep roll-off with strong delay peaks at the band edges.

![Group delay of the 1 kHz octave band for the five architectures: Bessel nearly flat, Chebyshev and Elliptic peaking at the band edges](https://docs.jmrp.io/phonometry/media/group_delay_comparison.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy.signal import group_delay
from phonometry import filters

fs = 48000
w = np.logspace(np.log10(500), np.log10(2000), 1024)
fig, ax = plt.subplots(figsize=(9, 5))
for ftype in ("butter", "cheby1", "cheby2", "ellip", "bessel"):
    bank = filters.OctaveFilterBank(fs, fraction=1, order=6, limits=[800, 1200],
                            design=filters.FilterDesign(filter_type=ftype))
    idx = int(np.argmin(np.abs(np.array(bank.frequencies) - 1000)))
    fsd = fs / bank.factor[idx]
    # Group delay of an SOS cascade = sum of the sections' group delays
    gd = sum(group_delay((sec[:3], sec[3:]), w=w, fs=fsd)[1]
             for sec in bank.sos[idx])
    ax.semilogx(w, gd / fsd * 1000, label=ftype)
ax.set(xlim=(500, 2000), xlabel="Frequency [Hz]", ylabel="Group delay [ms]")
ax.grid(True, which="both", alpha=0.3)
ax.legend()
plt.show()
```

## 6. Zero-phase filtering

For offline analysis you can eliminate group delay entirely:
`OctaveFilterBank.filter(…, zero_phase=True)` filters each band
forward-backward (`scipy.signal.sosfiltfilt`), keeping band signals
time-aligned with the input. It is a per-call option on the bank, not an
argument of the one-shot `octave_filter()`. The effective attenuation doubles and the
effective passband narrows, lowering the measured broadband band level by
about 0.4 dB per band (filtering twice squares the magnitude, and an order-6
Butterworth band then passes 11/12 of its noise bandwidth, −0.38 dB; a pure
in-band tone is unaffected); prefer forward
filtering when the absolute band SPL must match single-pass conventions, and
reserve zero-phase for when the temporal envelope matters (e.g. reverberation
decay). The option is incompatible with stateful (block) processing.

```python
import numpy as np
from phonometry import filters

fs = 48000
t = np.linspace(0, 0.5, int(fs * 0.5), endpoint=False)
y = np.sin(2 * np.pi * 250 * t) + np.sin(2 * np.pi * 1000 * t)

bank = filters.OctaveFilterBank(fs=48000, fraction=3)
filtered = bank.filter(y, sigbands=True, zero_phase=True)
spl, freq, xb = filtered.levels, filtered.frequencies, filtered.bands
```

![Causal versus zero-phase filtering of a tone burst: the zero-phase output stays time-aligned with the input](https://docs.jmrp.io/phonometry/media/zero_phase_comparison.svg)

*Causal filtering delays the burst by the filter's group delay; zero-phase
filtering keeps it aligned with the input.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import filters

fs = 48000
t = np.linspace(0, 0.15, int(fs * 0.15), endpoint=False)
x = np.zeros_like(t)                      # 250 Hz tone burst mid-frame
start, end = int(0.05 * fs), int(0.10 * fs)
x[start:end] = np.sin(2 * np.pi * 250 * t[start:end]) * np.hanning(end - start)

bank = filters.OctaveFilterBank(fs=fs, fraction=1, order=6, limits=[200.0, 300.0])
fwd = bank.filter(x, sigbands=True, calculate_level=False).bands
zp = bank.filter(x, sigbands=True, calculate_level=False,
                       zero_phase=True).bands

fig, ax = plt.subplots(figsize=(9, 4.5))
ax.plot(t, x, color="gray", alpha=0.5, label="Input burst (250 Hz)")
ax.plot(t, fwd[0], label="Causal (group delay)")
ax.plot(t, zp[0], "--", label="zero_phase=True (aligned)")
ax.set(xlabel="Time [s]", ylabel="Amplitude")
ax.legend()
plt.show()
```

## Coming from PyOctaveBand

phonometry was published as PyOctaveBand until 3.0.0, and this filter bank is
where that package began. Code written for it changes in these places:

| PyOctaveBand | phonometry 4.0 |
| --- | --- |
| `from pyoctaveband import octavefilter` | `from phonometry import filters` |
| `spl, freq = octavefilter(x, fs, fraction=3)` | `result = filters.octave_filter(x, fs, fraction=3)`, then `result.levels` and `result.frequencies` |
| `spl, freq, xb = octavefilter(x, fs, fraction=3, sigbands=True)` | the same call with `sigbands=True`, then `result.bands` for the band signals |
| `spl, freq = bank.filter(x)` on an `OctaveFilterBank` | `result = bank.filter(x)`, read the same way |
| `f_cen, f_low, f_high, labels = getansifrequencies(fraction=3)` | `bands = filters.nominal_frequencies(3)`, then `bands.frequencies`, `bands.lower_edges`, `bands.upper_edges` and `bands.labels` |
| `normalizedfreq(3)` | `filters.normalized_frequencies(3)` |
| `filter_type=`, `ripple=`, `attenuation=` | `design=filters.FilterDesign(filter_type=..., ripple=..., attenuation=...)` |
| `filter_type="cheby2"` or `"ellip"` with the default `attenuation`, 60 dB | the default has been 72 dB since 3.1, which makes the default `cheby2` bank class 1; `design=filters.FilterDesign(filter_type=..., attenuation=60.0)` gives the old numbers |
| `calibration_factor=`, `dbfs=` | `calibration=filters.LevelCalibration(factor=..., dbfs=...)` |
| `show=`, `plot_file=` | `response_plot=filters.ResponsePlot(show=..., file=...)` |

The transition package `pyoctaveband` pins `phonometry>=3.0.0,<4`, so
`import pyoctaveband` works on 3.x only: code moves to the names above by
changing its import, not by updating that package.
[Upgrading from 3.3 to 4.0](https://docs.jmrp.io/phonometry/start/upgrading/) lists the rest of
what 4.0 changed, and the
[changelog](https://github.com/jmrplens/phonometry/blob/main/CHANGELOG.md) what 3.0
to 3.3 changed after PyOctaveBand 2.0.0.

## What this guide covers

- **Covered.** IEC 61260-1:2014's band-edge mathematics (clauses 5.2-5.6), its nominal band
  labels (Annex E) and the ISO 266:1997 preferred-frequency series behind the
  octave and one-third-octave labels of `nominal_frequencies`. The library
  designs each band as an SOS cascade across five architectures (Butterworth,
  Chebyshev I/II, Elliptic, Bessel), plus the RBJ Audio EQ Cookbook's
  `ParametricEQ`, with band decomposition and zero-phase filtering.

- **Not covered.** The compared responses of the five architectures, the full 1/1 and 1/3 octave
  gallery and the per-architecture usage examples, including the Linkwitz-Riley
  crossover, are [Filter Architecture
  Gallery](https://docs.jmrp.io/phonometry/signals/filters/filter-gallery/). The Table 1 class
  acceptance masks and their verification have moved to [Filter Class
  Verification](https://docs.jmrp.io/phonometry/signals/filters/filter-compliance/). Near Nyquist,
  the bilinear transform warps the frequency axis and the bank has no correction
  for it (unlike `WeightingFilter`'s fitted `high_accuracy` design): keep the top band
  edge comfortably below Nyquist or raise `fs`, and confirm the margin with
  `verify_filter_class`.

## See also

- [Filter Architecture Gallery](https://docs.jmrp.io/phonometry/signals/filters/filter-gallery/): the
  five architectures compared at the band edges, the full response gallery
  and per-architecture usage, with the Linkwitz-Riley crossover.
- [Filter Class Verification (IEC 61260-1)](https://docs.jmrp.io/phonometry/signals/filters/filter-compliance/):
  the Table 1 acceptance mask, class 0 and the compliance fiche of the banks
  designed here.
- API reference: [`phonometry`](https://docs.jmrp.io/phonometry/reference/api/filters/phonometry/), [`filters.core`](https://docs.jmrp.io/phonometry/reference/api/filters/core/) and [`filters.weighting`](https://docs.jmrp.io/phonometry/reference/api/filters/weighting/).
- Theory: [Octave Band Frequencies](https://docs.jmrp.io/phonometry/reference/theory/signal-analysis/#octave-band-frequencies-ansi-s111--iec-61260): where the base-10 midband grid and the band edges come from, and why the bank is designed on them rather than on nominal labels.

## Quick answers

### How are fractional-octave centre frequencies and band edges defined?

IEC 61260-1:2014 (clauses 5.2-5.6) builds every band from the base-10
octave ratio $G = 10^{3/10} \approx 1.99526$, so one octave is not exactly
2. Mid frequencies follow $f_\mathrm{m} = 1000 \cdot G^{x/b}$ for odd $b$ and
$f_\mathrm{m} = 1000 \cdot G^{(2x+1)/2b}$ for even $b$ (so 1 kHz is a band mid
frequency in the odd fractions and a band *edge* in the even ones), and the
edges are $f_1 = f_\mathrm{m} G^{-1/2b}$ and $f_2 = f_\mathrm{m} G^{+1/2b}$ in both cases; every
one-third-octave band spans $G^{1/3} \approx 1.2589$, ten bands per decade.

## References

- **American National Standards Institute. (2004).** [*Specification for octave-band and fractional-octave-band analog and digital filters*](https://webstore.ansi.org/standards/asa/ansis1112004) (ANSI S1.11-2004). Acoustical Society of America.
  The band-edge convention on which every bank of this guide places its −3 dB points.
- **Bristow-Johnson, R. (2021).** [*Audio EQ Cookbook*](https://www.w3.org/TR/audio-eq-cookbook/). W3C Working Group Note (ed. R. Toy), 8 June 2021.
  The biquad coefficient recipes and the Q / bandwidth / shelf-slope parameterization behind ParametricEQ (section 4).
- **International Electrotechnical Commission. (2014).** [*Electroacoustics — Octave-band and fractional-octave-band filters — Part 1: Specifications*](https://webstore.iec.ch/en/publication/5063) (IEC 61260-1:2014).
  The band-edge mathematics of section 1 (base-10 mid frequencies and band edges, clauses 5.2-5.6) and the nominal band labels behind every bank designed here.
- **International Organization for Standardization. (1997).** [*Acoustics — Preferred frequencies*](https://www.iso.org/standard/1350.html) (ISO 266:1997).
  The preferred-frequency series behind the octave and one-third-octave band labels reported by nominal_frequencies.
- **Oppenheim, A. V., & Schafer, R. W. (2010).** [*Discrete-time signal processing*](https://openlibrary.org/isbn/9780131988422) (3rd ed.). Pearson.
  The pole-zero, stability and multirate theory condensed in section 1: SOS cascades, the bilinear transform and decimation (ISBN 978-0-13-198842-2).
- **Smith, J. O. (n.d.).** [*Introduction to digital filters with audio applications*](https://ccrma.stanford.edu/~jos/filters/). Center for Computer Research in Music and Acoustics (CCRMA), Stanford University.
  A free online-book companion treatment of digital-filter design and analysis, from pole-zero geometry to filter stability.