# Theory: Vibration

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/theory/vibration/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/theory/vibration/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-15
Updated: 2026-11-16T21:36:13Z
Standards: ISO/TS 7849-1:2009; ISO/TS 7849-2:2009
Verified: 3 conformance checks (ISO/TS 7849-1:2009; ISO/TS 7849-2:2009) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Human vibration weightings and metrics, the multiple-shock spinal model, and the point mobility and radiation efficiency of structure-borne sound.

---

This page collects the theory behind human vibration: the ISO 8041-1 frequency weightings, the whole-body and hand-arm metrics of ISO 2631-1 and ISO 5349, the action and limit values of Directive 2002/44/EC, and the ISO 2631-5 multiple-shock spinal model. It then turns from people to structures: the driving-point mobilities that govern how much power a point force injects into a plate, beam or rod, and the radiation efficiency that turns that vibration back into airborne sound (the pair EN 12354-5 and ISO 7849 rest on). It is part of the [theory reference](https://docs.jmrp.io/phonometry/reference/theory/).

## Human vibration (ISO 8041-1, ISO 2631-1/2, ISO 5349-1/2, Directive 2002/44/EC)

Human response to vibration depends on frequency, axis and body part, so
acceleration is filtered by the frequency weightings of ISO 8041-1:2017 before
any metric. Each weighting is the analog cascade
$H(s) = H_\mathrm{h}(s) H_\mathrm{l}(s) H_\mathrm{t}(s) H_\mathrm{s}(s)$ (Formula 5): two-pole Butterworth
band-limiting high-pass and low-pass stages (Formulae 1/2), an
acceleration–velocity transition (Formula 3, carrying the only non-unity gain,
$K = 1.024$ for Wb) and an upward step (Formula 4), with the Table 3 corner
frequencies and Q factors; a corner at infinity collapses its stage to unity
(Table 3 NOTEs). One cascade with nine parameter sets therefore produces the
whole family, and choosing the member is the first decision a vibration
measurement forces:

| Weighting | What it weights | Axis or contact point | Standard | Nominal range | Feeds |
| :--- | :--- | :--- | :--- | :--- | :--- |
| `Wk` | Vertical whole-body | z, seat surface or floor | ISO 2631-1 | 0.5–80 Hz | $a_\mathrm{w}$, VDV, $A(8)$ |
| `Wd` | Horizontal whole-body | x and y, seat surface or floor | ISO 2631-1 | 0.5–80 Hz | $a_\mathrm{w}$, VDV, $A(8)$ |
| `Wc` | Seat-back | x, backrest | ISO 2631-1 | 0.5–80 Hz | $a_\mathrm{w}$ (comfort) |
| `We` | Rotational | rx, ry, rz (per rad) | ISO 2631-1 | 0.5–80 Hz | $a_\mathrm{w}$ (comfort) |
| `Wj` | Recumbent, under the head | z | ISO 2631-1 | 0.5–80 Hz | $a_\mathrm{w}$ (comfort) |
| `Wm` | Building occupants | all axes | ISO 2631-2 | 1–80 Hz | $a_\mathrm{w}$ |
| `Wb` | Rail ride comfort | z | ISO 2631-4 | 0.5–80 Hz | $a_\mathrm{w}$ |
| `Wf` | Motion sickness | z | ISO 2631-1, clause 9 | 0.1–0.5 Hz | MSDV |
| `Wh` | Hand-transmitted | all three hand axes | ISO 5349-1 | 8–1000 Hz | $a_\mathrm{hv}$, $A(8)$ |

The nominal ranges are the ISO 8041-1 Table 1 columns, not the band-limiting
corners of Table 3: `Wh` is band-limited at 6.31 Hz and 1258.9 Hz but tabulated
from 8 Hz to 1 kHz, and the whole-body set is band-limited at 0.4 Hz and 100 Hz
and tabulated from 0.5 Hz to 80 Hz. Which weighting goes on which axis with
which multiplying factor is a posture question, answered by the posture map of
ISO 2631-1 Tables 1 and 2 reproduced in the
[Human Vibration guide](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/#which-weighting-on-which-axis).
All nine are implemented from the exact cascade: the filter is applied as the
exact complex response via FFT, magnitude *and* phase, not a bilinear-warped
digital approximation, and the ISO 8041-1 Annex B design-goal tables (B.1–B.9)
are reproduced to 0.1 %.

![All nine human-vibration weightings in decibels from 0.05 Hz to 1.5 kHz on a log frequency axis, colour-grouped into the whole-body weightings Wk, Wd and Wc, the rotational and recumbent weightings We and Wj, the building and rail weightings Wm and Wb, the motion-sickness weighting Wf peaking at 0.17 Hz, and the hand-arm weighting Wh peaking near 11 Hz; three bars above the curves mark the band each part of the family is tabulated over, 0.1 to 0.5 Hz for Wf, 0.5 to 80 Hz for the whole-body weightings and 6.3 to 1250 Hz for Wh](https://docs.jmrp.io/phonometry/media/vibration_weighting_family.svg)

*The family the one cascade produces, a Table 3 parameter set per curve. `Wk`,
the vertical whole-body weighting quoted most often, is the flat-topped curve
peaking near 6 Hz and 21 dB down at 100 Hz; `Wd` peaks two and a half octaves
below it, because the body is far more compliant horizontally at low frequency;
`Wf` sits an order of magnitude lower in frequency again; and `Wh` extends three
decades above, which is why the three sets are tabulated over the three
different bands drawn above the curves.*

### Getting the acceleration right

None of this survives a transducer in the wrong place. Whole-body vibration is
measured at the interface where it enters the body (ISO 2631-1, 5.3.1): for a
seated person the seat surface beneath the ischial tuberosities, the seat back
at its principal area of support, and the feet; and on a resilient surface the
transducer is interposed between person and surface in a mount that does not
greatly alter the pressure distribution (5.3.2), the usual design being the
semi-rigid disc of ISO 10326-1. The three translational transducers at one
location sit orthogonally and as close together as practicable, with up to 15°
of misalignment tolerated where exact alignment is impracticable (5.2.2–5.2.3);
the location, the orientation of the axes relative to gravity and the
measurement duration are all reported (5.2.2, 5.3.1, 5.5).

Hand-arm vibration is measured at the middle of the gripping zone where that is
reachable, and otherwise either side of the hand or on the underside of the
handle adjacent to it, with two positions averaged where the vibration differs
across the hand; flexibly mounted side handles are the standard case
(ISO 5349-2, 6.1.3 as revised by Amd 1:2015). A percussive tool can reach
20 000 to 50 000 m/s², almost all of it outside the 6.3 Hz to 1250 Hz evaluation
band, and that overload drives a piezoelectric transducer into **DC-shift**: a
false low-frequency component, exactly where the weighting has most gain
(6.2.4). A mechanical filter prevents it (Annex C); the standard's check is to
convert the unweighted band r.m.s. acceleration to a displacement
$d = a/(40 f^2)$ and compare it with the motion of the transducer you can
actually see; and a record showing DC-shift is **discarded**, because the
distortion contaminates the whole spectrum and deleting the low-frequency bands
does not rescue it. Magnitudes are averaged over complete operations or work
cycles, with at least three samples per operation, a total measuring time of at
least one minute, and samples shorter than about 8 s avoided (5.4.1). The
[Human Vibration guide](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/#0-getting-the-numbers)
carries the mass, attachment and grip-force constraints and the rest of the
fault list.

![Left: a chain-saw front handle of 30 mm diameter gripped by a hand over a gripping zone of about 100 mm, with three numbered accelerometer positions (under the hand at the middle of the gripping zone, either side of the hand, and on the underside of the handle next to the hand), the cable taped to the handle near the transducer, the grip force, and the basicentric x_h y_h z_h frame rotated so y_h lies along the handle axis. Right: the evaluation chain from the three Wh-weighted axis magnitudes to the vibration total value a_hv, the partial exposures A_i(8) over the contact times, and A(8) against the exposure action value 2.5 and exposure limit value 5 m/s^2 of Directive 2002/44/EC, with a box giving the mass, averaging, sampling and range rules](https://docs.jmrp.io/phonometry/media/diagram_hand_arm_vibration.svg)

*Three accelerometer positions of 6.1.3 on one handle, here the front handle of
a chain saw. The numbers 1 to 3 are the drawing's, not the standard's: 6.1.3
numbers none, and Annex A of the same amendment calls two other places, those of
the emission standards, positions 1 and 2. Position 1, under the hand at the
middle of the gripping zone, is the most representative and the one that needs
an adaptor. Positions 2, either side of the hand, and 3, the underside of the
handle next to the middle of the hand, are together where 6.1.3 says most
practical measurements put the accelerometers, and on a side handle it
recommends one on each side of the hand and the average of the two. The cable is taped
to the handle near the transducer because a cable the vibration deforms produces
a signal of its own (6.2.3), and the frame is the basicentric one of ISO 5349-1
Figure 1, rotated so that $y_\mathrm{h}$ lies along the handle axis. The box
lists the rules a record has to keep: transducer and mount under 5 % of the mass
they are fixed to (6.1.5), linear averaging over complete work cycles (6.1.11),
the sampling rule of 5.4.1 above, and the lowest input range that does not
overload, found by trial (6.1.10). The chain on the right is the one the next
section writes out: three $W_\mathrm{h}$-weighted axes, the total value
$a_\mathrm{hv}$, one partial exposure per operation and their sum in quadrature
$A(8)$, read against 2.5 and 5 m/s².*

### Weighted metrics and daily exposure

The weighted metrics follow ISO 2631-1:1997: running rms with linear or
exponential integration (Eqs. 2/3), **MTVV** as its maximum (Eq. 4), the
fourth-power **VDV** $= (\int a_\mathrm{w}^4\, dt)^{1/4}$ in $\mathrm{m/s}^{1.75}$
(Eq. 5), and the vibration total value
$a_\mathrm{v} = \sqrt{\sum_j k_j^2 a_{\mathrm{w}j}^2}$ (Eq. 10), whose multiplying factors $k_j$
belong to the posture and axis rather than to the metric: for a seated person
assessed for health, 1.4 on `Wd`-weighted x and y and 1.0 on `Wk`-weighted z
(clause 7.2.3).

![Whole-body vibration measurement chain: a triaxial accelerometer at the seat/body interface of a seated person measures the x, y and z acceleration, with y pointing into the page, to the left side of the body; each axis is band-limited and frequency-weighted (Wk vertical, Wd horizontal) per ISO 8041-1, reduced to a weighted r.m.s. a_w and VDV per ISO 2631-1, and the highest frequency-weighted axis value max(1.4 a_wx, 1.4 a_wy, a_wz) is normalised to the daily exposure A(8) and assessed against the EAV and ELV of Directive 2002/44/EC](https://docs.jmrp.io/phonometry/media/diagram_human_vibration.svg)

*The whole-body chain on one seat. The triaxial accelerometer sits at the
seat/body interface, the only one of the three locations of 5.3.1 the drawing
shows (it draws no transducer on the seat back or under the feet); each axis is
band-limited and weighted, `Wd` on x and y and `Wk` on z, and reduced to a
weighted r.m.s. value and a VDV. The last box is where the factors of clause
7.2.3 act: the daily exposure is built on the largest of $1.4a_{\mathrm{w}x}$,
$1.4a_{\mathrm{w}y}$ and $a_{\mathrm{w}z}$, one axis and not the vector total,
which is the distinction the paragraphs below turn on.*

**The crest factor decides which of them to report.** It is the peak of the
weighted acceleration divided by its rms over the same interval (clause 6.2.1),
so it measures how much of the exposure is concentrated in short events: a
steady random vibration sits near 3 to 4, and a value approaching 9 means the
average is being set by transients the rms understates. ISO 2631-1 clause 6.2.2
treats the basic rms method as normally sufficient while the crest factor stays
at or below 9 and sends anything above it to the additional methods of clause
6.3, because occasional high peaks contribute little to an rms and a great deal
to a fourth-power dose. Two ratios decide the same question without relying on
the crest factor alone (clause 6.3.3): report the additional value as well once
$\mathrm{MTVV}/a_\mathrm{w}$ exceeds 1.5 or $\mathrm{VDV}/(a_\mathrm{w} T^{1/4})$ exceeds 1.75.
Both are measured over the actual evaluation interval, so splitting a record
into short blocks lowers the crest factor artificially; and where an additional
method is used, the basic value is still reported beside it (clause 5.6).

Hand-arm exposure follows ISO 5349-1:2001: $a_\mathrm{hv}$ (Eq. 1, all $k = 1$), daily
exposure $A(8) = a_\mathrm{hv} \sqrt{T/T_0}$ with $T_0 = 8$ h (Eq. 2), partial
exposures combined in quadrature (ISO 5349-2:2001, Eqs. 1–3), and the Annex C
vascular-risk model $D_\mathrm{y} = 31.8\ A(8)^{-1.06}$ for the years to 10 %
white-finger prevalence (unrelated to the acceleration dose $D_\mathrm{z}$ below). The
Directive 2002/44/EC action and limit values are built in: hand-arm $A(8)$
2.5/5.0 m/s², whole-body $A(8)$ 0.5/1.15 m/s² or VDV 9.1/21.0
$\mathrm{m/s}^{1.75}$ (Article 3), the VDV route applying where a member state
has adopted it.

**The two limits are assessed on two differently built quantities.** Hand-arm
exposure is assessed on the vector total $a_\mathrm{hv}$, every $k = 1$. Whole-body
exposure is assessed on the *single dominant axis*: the largest of
$1.4a_{\mathrm{w}x}$, $1.4a_{\mathrm{w}y}$ and $a_{\mathrm{w}z}$ (Directive Annex Part B, with the clause
7.2.3 factors; ISO 2631-1 clause 7.2.2 assesses each axis independently), and
never on the vector total, which is the comfort quantity of clause 8.
`vibration.wbv_exposure_basis` builds the whole-body basis and
`vibration.vibration_total_value` the vector total; feeding the second to
$A(8)$ is the commonest error in an occupational assessment and always inflates
the answer. For the three axes 0.35, 0.28 and 0.62 m/s², the Directive basis is
0.62 m/s² and the health-weighted vector total 0.88 m/s², an overstatement of
42 %.

The ISO 5349-2 worked examples are reproduced (E.2.1: 7.4 m/s² for 2.5 h →
$A(8) = 4.1$ m/s²; E.3 forestry, three tools → 3.6 m/s²), as are the
ISO 5349-1 Table C.1 exposure-duration rows.

### Multiple shocks (ISO 2631-5)

Repeated shocks damage the lumbar spine through peak compression rather than
average energy, so ISO 2631-5:2018 replaces the Wk weighting with the
seat-to-spine transfer function of clause 5.2 (Formula 1: one complex zero and
six complex pole pairs, unity at DC, resonance near 5 Hz,
$|H| \approx 1.54$ at 5 Hz) and accumulates the positive spinal-response peaks with a
sixth-power (Palmgren-Miner) dose (clause 5.3, Formulae 3/4):

$$
D_\mathrm{z} = 1.07 \left( \sum_i A_{\mathrm{z},i}^6 \right)^{1/6}, \qquad
D_\mathrm{zd} = D_\mathrm{z}\ (t_\mathrm{d} / t_\mathrm{m})^{1/6}.
$$

Annex C converts the daily dose to a compressive stress $S_\mathrm{d} = m_\mathrm{z} D_\mathrm{zd}$
($m_\mathrm{z} = 0.029/0.025$ MPa per m/s² for the 82 kg male / 64 kg female), tracks
the age-declining ultimate strength $S_\mathrm{u} = 6.75 - S_\mathrm{age}(b + i)$ and forms
the cumulative stress variable $R$ (Formulae C.3/C.4), mapped to an injury
probability by the Table C.1 Weibull law $\Pi = 1 - \mathrm{e}^{-(R/\alpha)^\beta}$.
The spinal filter is evaluated analytically in the frequency domain and
validated against the Annex D 256 Hz digital-filter tabulation within the
clause 5.2 tolerance; the Annex C worked example (five 40 m/s² shocks per day
over 20 years) is reproduced: $D_\mathrm{zd} = 55.97$ m/s², $R = 1.22$,
$\Pi = 0.37$. The Annex A finite-element spinal model (distributed by ISO as
separate software) is out of scope.

![Left: the seat-to-spine transmissibility rising to about 1.6 near a 5 Hz resonance then rolling off to near zero by 80 Hz. Right: the Weibull probability of lumbar injury versus the stress variable R for male and female, with the 10, 50 and 90 percent risk levels and the Annex C male example at R = 1.22, about 37 percent](https://docs.jmrp.io/phonometry/media/multiple_shock.svg)

*The two objects of the model. Left, the clause 5.2 seat-to-spine
transmissibility: unity at DC, peaking at $|H| \approx 1.54$ near 5 Hz and
rolling off above it, which is why $W_\mathrm{k}$ had to be replaced for shocks. Right,
the Table C.1 Weibull law $\Pi(R)$ with the Annex C worked example marked at
$R = 1.22$, $\Pi = 0.37$: the risk rises steeply over a narrow band of $R$, so
a dose that doubles does not double the probability.*

See the [Human Vibration guide](https://docs.jmrp.io/phonometry/vibration/human/human-vibration/) and the
[Multiple-Shock Vibration guide](https://docs.jmrp.io/phonometry/vibration/human/multiple-shock-vibration/) for usage.

## Point mobilities and radiation efficiency (Cremer 5, Hopkins 2.9)

The notation restarts here: $S$ is a cross-sectional area, $m'$ a mass per unit
length and $m''$ a mass per unit area, none of them the stress and dose symbols
of the human-vibration sections above.

The vibrational power a point force injects into a structure is
$W = \tfrac12 |F|^2\,\mathrm{Re}\{Y\}$ (Cremer Eq. 5.23), so the driving-point
**mobility** $Y$ (the reciprocal of the impedance) governs how much energy the
structure absorbs. For infinite structures these are closed forms (Cremer
Table 5.1): an infinite thin plate is a pure resistance $Z = 8\sqrt{B'\,m''}$
(real, frequency independent, with $B'$ the bending stiffness per unit width and
$m''$ the mass per unit area), an infinite beam has
$Y = (1-\mathrm{j})/(4 m' c_\mathrm{B})$ (a 45-degree phase, falling as $\omega^{-1/2}$
through the bending wave speed $c_\mathrm{B}$), and a longitudinal rod has
$Z = \rho c_\mathrm{L} S$. These supply the receiver mobility EN 12354-5 needs when no
measurement exists, and are the theoretical companions of the measured ISO 7626
mobilities.

**Where the substitution holds.** No real structure is infinite, and a finite
one does not have a smooth driving-point mobility: below and around its first
few modes the measured $|Y|$ swings by tens of decibels between resonance and
antiresonance. The closed form is the *average* about which it oscillates, so it
becomes meaningful only once several modes fall inside the analysis band, which
is why it is used with octave or one-third-octave inputs and never read at a
single frequency, and why it is defensible in the mid and high bands where
structure-borne power predictions are usually made and unreliable in the lowest
bands of a small or lightly damped element. The closed forms also assume
excitation far from any boundary: driving near an edge or a corner raises the
local stiffness and lowers the mobility, and driving a ribbed or otherwise
inhomogeneous plate invalidates the single $B'$ the plate formula rests on. Take
the receiver mobility from a measurement when the element is small, lightly
damped, or excited near a boundary.

![Two stacked panels against frequency from 0.5 Hz to 2 kHz on a log axis. Top: mobility magnitude for a single-degree-of-freedom resonator, which resonates, against three infinite-structure closed forms: a 140 mm concrete plate, flat at about 2.6 times ten to the minus six metres per newton-second; a 100 by 200 mm steel beam falling as the inverse square root of frequency; and a steel strut in longitudinal motion, flat. Bottom: the phase of each, zero for the plate and the rod, minus 45 degrees for the beam](https://docs.jmrp.io/phonometry/media/infinite_mobilities.svg)

*The three closed forms drawn against the finite resonator. The 140 mm concrete
plate is real and frequency-independent at $2.6 \times 10^{-6}$ m/(N·s); the
100 × 200 mm steel beam falls as $f^{-1/2}$, a factor 63 over the twelve
octaves shown, at a constant −45°; the longitudinal strut is real and flat.
None of them resonates, which is exactly the difference from a finite structure
and the reason the closed forms are band-average substitutes rather than
point-by-point predictions.*

How efficiently a bending plate then radiates the airborne power is its
**radiation efficiency** $\sigma$: the ratio of the power the plate actually
radiates to the power a large baffled piston ($ka \gg 1$, with $a$ its radius
and $k$ the wavenumber in air) of the same area, vibrating with the same
spatially averaged mean-square velocity, would radiate into the same half-space.
So $\sigma = 1$ is the fully coupled case, and a small value means the plate is
short-circuiting itself. Below the critical frequency $f_\mathrm{c}$ (the frequency at
which the bending wavelength in the plate matches the wavelength in air), the
bending wavelength is the shorter of the two, so adjacent half-cells of the
plate pump air back and forth into each other and radiation survives only where
that cancellation is interrupted, at the edges and the corners. Sub-critical
$\sigma$ therefore depends on the plate's perimeter and area as well as on its
material, and it is small: a 12.5 mm plasterboard sheet 4 × 3 m
($f_\mathrm{c} \approx 2.6$ kHz) runs from $\sigma = 0.0017$ at 31.5 Hz to 0.080 at
2 kHz, while a 100 mm concrete slab of the same size ($f_\mathrm{c} \approx 180$ Hz) is
already at 0.12 at 31.5 Hz. Above $f_\mathrm{c}$ the quoted limit
$\sigma \to (1 - f_\mathrm{c}/f)^{-1/2} \to 1$ (Leppington/Maidanik, Hopkins
Eqs 2.227-2.230) applies, but it is singular exactly at $f = f_\mathrm{c}$, so the
coincidence band is evaluated with the separate at-coincidence expression
(Eq. 2.230) and the peak just above $f_\mathrm{c}$ is finite (1.89 for that concrete
slab), set by the plate's size and damping. Because $\sigma$ is exactly the
radiation factor $\varepsilon$ of ISO 7849, predicting it closes the sound-power-
from-vibration chain without a power measurement, and it drives the resonant
transmission path of the
[panel sound insulation theory](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/#predicted-panel-sound-insulation-bies-72-hopkins-294310-cremer-5),
where $f_\mathrm{c}$ itself is defined.

The clip from the [Sound Power from Vibration guide](https://docs.jmrp.io/phonometry/devices/emission/vibration-sound-power/) runs the two regimes on one 10 mm steel plate in air ($f_\mathrm{c} = 1205$ Hz), driven along its whole length, once at $f_\mathrm{c}/2$ and once at $2f_\mathrm{c}$.

**Video:** [A steel plate driven below and above its coincidence frequency](https://docs.jmrp.io/phonometry/media/anim_elastic_radiation_efficiency.webm): A bending wave runs to the right along a steel plate with air above it. In the lower-frequency panel the plate ripples with a wavelength shorter than the sound wavelength and the pressure above it forms alternating lobes that cling to the plate and fade out within a few centimetres, so nothing leaves. In the higher-frequency panel the plate ripples with a longer wavelength and a plane beam of pressure departs at forty-five degrees along the whole driven span, growing as it goes.

*What the clip shows is the infinite-plate mechanism alone (Hopkins 2.9.2). At 602 Hz the bending wavelength, 0.40 m, is shorter than the 0.57 m of sound in air, no angle satisfies $\sin\theta = \lambda/\lambda_\mathrm{B}$, and the air carries only a skin of alternating lobes that decays with a height of $1/\sqrt{k_\mathrm{B}^2 - k_0^2} = 0.091$ m and takes no power away (Eq. 2.216); at 2410 Hz the bending wavelength, 0.20 m, is longer than the 0.14 m in air and a plane beam leaves at 45° (Eq. 2.203). It does not show the other half of the paragraph above: the scene is an effectively infinite plate, with no edge that radiates, so the sub-critical radiation that survives at the edges and corners of a finite plate, the part that makes a real $\sigma$ small and not zero, is not in it.*

See the [Predicting Panel Sound Insulation guide](https://docs.jmrp.io/phonometry/buildings/design/panel-sound-insulation/)
for usage.

![Normalized receptance, mobility and accelerance magnitudes of a single-degree-of-freedom resonator on a log-log frequency axis, all peaking at the resonance](https://docs.jmrp.io/phonometry/media/mechanical_mobility.svg)

*Not one of the closed forms above: this is a **finite** one-degree-of-freedom
resonator, receptance, mobility and accelerance being the same resonance seen
through the three kinematic quantities. It is here as the contrast: the
infinite-structure results are frequency-independent or smoothly falling,
while anything finite resonates.*

![Driving-point mobility magnitude of a single-degree-of-freedom resonator on log-log axes, climbing along the stiffness line below resonance, falling along the mass line above it, and peaking at one over the damping coefficient at the resonance](https://docs.jmrp.io/phonometry/media/mobility_result_lines.svg)

*The same point read as a diagnosis: below resonance the magnitude climbs the
**stiffness line** $\omega/k$, above it it falls along the **mass line**
$1/(\omega m)$, and the peak height is set by the damping alone. A real
structure has many such resonances, and the infinite-structure closed forms
above are the average the measured mobility oscillates about, not the value it
takes at a given frequency, which is why they are used with octave or
third-octave inputs and are least trustworthy in the lowest bands of a small
or lightly damped element.*

## References

- **Cremer, L., Heckl, M., & Petersson, B. A. T. (2005).** *Structure-borne sound: Structural vibrations and sound radiation at audio frequencies* (3rd ed.). Springer. https://doi.org/10.1007/b137728
  ISBN 978-3-540-22696-3. The driving-point power W = (1/2) \|F\|^2 Re{Y} (Eq. 5.23) and the closed-form infinite-structure mobilities and impedances (Table 5.1) of the point-mobility section.
- **Griffin, M. J. (1996).** [*Handbook of human vibration*](https://shop.elsevier.com/books/handbook-of-human-vibration/griffin/978-0-12-303041-2). Academic Press.
  ISBN 978-0-12-303041-2. The biodynamic and health-effect evidence behind the ISO 8041-1 weightings, the rms/MTVV/VDV dose measures and the spinal-injury rationale of the multiple-shock model.
- **Hopkins, C. (2007).** *Sound insulation*. Butterworth-Heinemann. https://doi.org/10.4324/9780080550473
  ISBN 978-0-7506-6526-1. The bending-plate radiation-efficiency theory (Eqs 2.227-2.230, the Leppington/Maidanik high-frequency limit) behind the radiation-efficiency section.
- **International Organization for Standardization. (2009).** [*Acoustics — Determination of airborne sound power levels emitted by machinery using vibration measurement — Part 1: Survey method using a fixed radiation factor*](https://www.iso.org/standard/40537.html) (ISO/TS 7849-1:2009).
  The radiation factor that equals the radiation efficiency, closing the sound-power-from-vibration chain of the radiation-efficiency section (survey method, fixed radiation factor).
- **International Organization for Standardization. (2009).** [*Acoustics — Determination of airborne sound power levels emitted by machinery using vibration measurement — Part 2: Engineering method including determination of the adequate radiation factor*](https://www.iso.org/standard/40538.html) (ISO/TS 7849-2:2009).
  The engineering method of the same sound-power-from-vibration chain, determining the adequate radiation factor from measurement.
- **International Organization for Standardization. (2011).** [*Mechanical vibration and shock — Experimental determination of mechanical mobility — Part 1: Basic terms and definitions, and transducer specifications*](https://www.iso.org/standard/50426.html) (ISO 7626-1:2011).
  The measured driving-point mobilities that the closed-form infinite-structure results of the point-mobility section are the theoretical companions of.
- **Mansfield, N. J. (2004).** [*Human response to vibration*](https://www.routledge.com/Human-Response-to-Vibration/Mansfield/p/book/9780415282390). CRC Press.
  ISBN 978-0-415-28239-0. A compact modern walkthrough of the ISO 2631-1 whole-body and ISO 5349 hand-arm evaluation chains summarised on this page.
