# Theory: Materials and Surfaces

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/theory/materials-surfaces/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/theory/materials-surfaces/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-20
Updated: 2026-11-16T21:36:13Z
Standards: ISO 17497-1:2004+A1:2014; ISO 17497-2:2012; ISO 10534-2:1998; ASTM E2611-19; ISO 9053-1:2018
Verified: 10 conformance checks (ISO 17497-1:2004+A1:2014; ISO 17497-2:2012; ISO 10534-2:1998) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Surface scattering and diffusion, in-situ road-surface absorption and acoustic material characterisation behind phonometry.

---

This page collects the theory behind materials and surfaces: surface scattering and diffusion, in-situ road-surface absorption, and acoustic material characterisation from the weighted absorption rating to airflow resistance and the impedance tube. It is part of the [theory reference](https://docs.jmrp.io/phonometry/reference/theory/). The ISO 354 reverberation-room measurement that feeds the ISO 11654 rating is covered in [Rooms and Buildings](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/).

## Surface scattering and diffusion (ISO 17497-1, ISO 17497-2)

The two parts of ISO 17497 answer different questions about the same surface,
and their answers do not substitute for one another. Part 1 measures **how
much** of the reflected energy leaves the specular direction: one number per
band, which is exactly what a geometrical or ray-based room model consumes as
its scattering probability. Part 2 measures **how uniformly** the reflected
energy is spread over angle, which is what tells a designer whether a diffuser
works, and it is deliberately blind to how much energy was redirected at all.
The classic failure is to read one as the other: a set of battens that merely
sends the reflection off in a different direction scores a high scattering
coefficient and a low normalised diffusion coefficient, because redirection is
not dispersion (Cox & D'Antonio 3rd ed., §5.1 and Fig. 5.2). The measurement
conditions differ too: Part 1 is a random-incidence reverberation-room method
restricted to shallow samples that absorb little ($\alpha_\mathrm{s} \le 0.50$,
clause 6.3.4), Part 2 a free-field method with neither restriction, so a
surface can legitimately have only one of the two coefficients published.

Both run from 0 to 1, and neither reaches 1 in practice. Scattering rises with
frequency as the surface relief becomes comparable with the wavelength, and a
surface meant to be flat stays low across the band: ISO 17497-1 Table 1 caps
the base plate of the apparatus itself at 0.05 to 0.25, which is the standard's
own definition of "not scattering". Real diffusers rarely exceed a diffusion
coefficient of 0.7 (ISO 17497-2, definition 3.9, Note 1).

### Random-incidence scattering coefficient (ISO 17497-1)

A rough surface splits the reflected energy into a specular and a scattered
part; the scattering coefficient $s$ is the non-specular energy fraction.
ISO 17497-1:2004+A1:2014 measures it in a reverberation room with the test
sample on a turntable: four reverberation times, stationary and rotating,
each without and with the sample (Table 2), give the random-incidence
absorption $\alpha_\mathrm{s}$ (clause 8.1.1, Formula 1) and the *specular* absorption
$\alpha_\mathrm{spec}$ (clause 8.1.2, Formula 4). Rotation decorrelates the scattered
reflections between decays, so they average out and register as extra
"absorption", and the scattering coefficient follows (clause 8.1.3,
Formula 5):

$$
s = \frac{\alpha_\mathrm{spec} - \alpha_\mathrm{s}}{1 - \alpha_\mathrm{s}},
$$

each $\alpha$ being a two-condition Sabine difference
$55.3 (V/S) [1/(c_b T_b) - 1/(c_a T_a)] - 4 (V/S)(m_b - m_a)$ with
$c = 343.2 \sqrt{(273.15 + t)/293.15}$ (Formula 2) and $m$ from ISO 9613-1
via $m = \alpha_{dB}/(10 \log_{10} e)$ (Formula 3). The base plate itself must
scatter little: Table 1 caps its coefficient (Formula 6) at 0.05–0.25 across
100 Hz – 5 kHz (clause 6.2). Negative $s$ is truncated to zero for
presentation (clause 8.3), but values above 1 near grazing bands are kept
(clause 6.3.2). The Annex A uncertainty chain ($u_\alpha$, Formulae A.3/A.4;
$u_s$, Formula A.5; $U = 2 u_s$) is implemented. Since the standard prints no
worked example, the reference value is a synthetic end-to-end chain
($V = 200$ m³, $S = 10$ m², $T = 8.0/6.0/7.5/5.0$ s → $s = 0.093$) plus the
Formula A.5 hand value $u_s = 0.0297$.

**What the four decays require.** The mechanism only works if the rotation is
sampled properly and the sample is big enough to be a surface rather than an
object. At full scale ($N = 1$) the sample is circular with a diameter of at
least 3.0 m, or square with a 2.65 m edge on a base plate of at least 3.75 m
diameter, and its structural depth must stay below $d/16$ of the turntable
diameter or the method stops measuring roughness (clauses 6.3.1–6.3.2); no part
of the turntable comes closer than 1.0 m to a room wall (6.2), and a sample with
rotational symmetry is offset from the rotation axis by at least $d/8$ (6.3.3).
Every linear dimension, and the room volume of $V \ge 200$ m³, scales by $1/N$
(by $N^{-3}$ for the volume) in a scale model. Each of the four reverberation
times is the arithmetic mean over at least two source and three microphone
positions, six combinations in all (clause 7.3). The rotating decays are built
from $n$ phase-locked averages at equal steps of $360^\circ/n$ with
$60 \le n \le 120$, $n = 72$ (5°) preferred, and the excitation must be
identical from step to step (clause 7.3): it is precisely the angle-to-angle
decorrelation that registers as the extra "absorption" the coefficient is built
from, so a drifting signal fakes scattering. For the same reason the room must
be time-invariant across the whole set: diffusers fixed, no rotating vanes, no
ventilation or air circulation running (6.1.1), and temperature and relative
humidity measured before and after each of the four situations (7.4).

The arrangement of ISO 17497-1 draws that requirement: the turntable is the only
thing that moves, and the two loudspeaker and three microphone positions stay
fixed.

![ISO 17497-1 random-incidence scattering setup: a reverberation room with the test sample on a turntable and base plate at least 1 m from the walls, two fixed loudspeaker positions and three fixed microphone positions, the turntable the only thing that moves, and the Table 2 mapping of T1 to T4 onto the random-incidence and specular absorption coefficients from which the scattering coefficient is derived](https://docs.jmrp.io/phonometry/media/diagram_scattering_reverb.svg)

![The random-incidence scattering coefficient s of a diffusing surface over the 13 one-third-octave bands from 250 to 4000 Hz, rising smoothly from near zero at low frequency towards 0.84 at 4 kHz](https://docs.jmrp.io/phonometry/media/scattering_coefficient.svg)

*A random-incidence scattering coefficient rising with frequency as the surface roughness becomes comparable with the wavelength.*

### Directional diffusion coefficient (ISO 17497-2)

ISO 17497-2:2012 measures, in the free field, how uniformly a surface spreads
its reflected polar response over $n$ microphones. Those microphones map a
semicircle around the sample's reference point (a two-dimensional goniometer,
in an anechoic room or a reflection-free zone) for a single-plane surface, or a
hemisphere (three-dimensional goniometer) for one that scatters in both planes
(clause 4), at an angular resolution of 5° or finer in both azimuth and
elevation, which is where an arc of 37 receivers over 180° comes from.
Far-field conditions are taken as met when at least 80 % of the receivers lie
outside the specular zone, for which the standard's working geometry is a 10 m
source distance and a 5 m receiver radius (clause 6.2.2); nearer arrangements
are legitimate for a near-field application but must be reported with the
source and receiver locations and the sample dimensions (6.2.1), because $d$ is
a property of *that* surface at *that* size and distance, not a material
constant. Each
source-receiver pair needs the impulse response with the test surface present
and the one with it absent, which is subtracted to remove background
reflections, plus a source response measured on the reference point whenever
more than one source or microphone is used (clause 7.3); the reflection is then
time-windowed away from the direct sound and the edge diffraction before the
levels $L_i$ are formed. The flat-reference measurement that the normalisation
below removes is a further, complete run on a plane surface of the same size.

![ISO 17497-2 free-field diffusion goniometer: a test sample on a turntable, a fixed loudspeaker source, and a semicircular arc of receiver microphones sampling the reflected polar response, from which the autocorrelation diffusion coefficient is computed](https://docs.jmrp.io/phonometry/media/diagram_diffusion_goniometer.svg)

The autocorrelation-based coefficient (clause 8.1, Formula 5) is

$$
d_\theta = \frac{\left( \sum_i p_i \right)^2 - \sum_i p_i^2}{(n - 1) \sum_i p_i^2},
\qquad p_i = 10^{L_i/10},
$$

1 for a perfectly uniform response and tending to 0 for a single specular
lobe; Formula 6 is the area-weighted form with $N_i = A_i / A_\mathrm{min}$ from the
Formula 8 solid-angle factors ($A_i = (4\pi/\Delta\phi) \sin^2(\Delta\theta/4)$
at the zenith). Normalizing against a flat reference reflector of the same
size removes edge diffraction (clause 8.2, Formula 7):
$d_{\theta,\mathrm{n}} = (d_\theta - d_{\theta,\mathrm{r}})/(1 - d_{\theta,\mathrm{r}})$. The
random-incidence value averages over the source positions: for a
two-dimensional boundary measurement the preferred sources sit at 0°, ±30° and
±60° from the reference normal (clause 6.2.2) and are averaged with weights
1:3:3:3:3, the outer four standing in for the solid angle they represent, while
a hemispherical measurement averages the Table 1 source positions with equal
weights (clause 8.4).

![A polar plot of the predicted reflected sound-pressure level of a six-period N=7 quadratic-residue diffuser over 37 receivers from -90 to 90 degrees, the energy concentrated in a fan of discrete grating lobes, giving an autocorrelation diffusion coefficient d of about 0.11](https://docs.jmrp.io/phonometry/media/diffusion_polar.svg)

*The object the coefficient is computed from, in the presentation clause 8.5
prescribes: one polar response per one-third-octave band and source position,
on a semicircular plot with a decibel radial axis. This is the six-period
$N = 7$ quadratic-residue diffuser of the anchor below, at 1 kHz. Its energy
sits in a fan of discrete grating lobes rather than in one specular lobe, which
is why $d_\theta$ is 0.11 where the flat reference of the same size scores
0.005, and why it is still nowhere near 1: the numerator rewards an even
response, and a comb of lobes is not even.*

Reference values: the model-predicted 37-receiver arc of
the published six-period $N = 7$ QRD (Cox & D'Antonio 3rd ed., Appendix B;
Hargreaves et al. 2000, Table I) at 1000 Hz gives $d_\theta = 0.1099$, its
flat reference $0.0049$ and $d_{\theta,\mathrm{n}} = 0.1055$; the band-averaged model
predictions match the published Appendix B BEM normalised diffusion in the
200-400 Hz bands within 0.01 (a low-band anchor: the broadband 100-5000 Hz
mean absolute deviation is about 0.09); zenith area factor 1.5710.

See the [Diffusers guide](https://docs.jmrp.io/phonometry/materials/diffusers/diffusers/) for usage.

## In-situ road surface absorption (ISO 13472-1, ISO 13472-2)

### Extended surface method (ISO 13472-1)

ISO 13472-1:2002 (extended surface method) recovers the normal-incidence
absorption of a road surface in place, from one microphone above it: the
direct and reflected components of an impulse response are separated by the
**subtraction technique** and the **Adrienne window** (clause 6.4: a sharp
leading edge, a mandated 5 ms flat top and a Blackman-Harris trailing edge),
and

$$
\alpha(f) = 1 - \frac{1}{K_\mathrm{r}^2} \left| \frac{H_\mathrm{r}(f)}{H_\mathrm{i}(f)} \right|^2,
\qquad K_\mathrm{r} = \frac{d_\mathrm{s} - d_\mathrm{m}}{d_\mathrm{s} + d_\mathrm{m}} = \frac{2}{3}
$$

for the mandatory geometry $d_\mathrm{s} = 1.25$ m, $d_\mathrm{m} = 0.25$ m (clause 4.2,
Annex C); $K_\mathrm{r}$ is the spherical-spreading ratio between the direct and the
image path. Ratioing the road measurement against one on a highly reflective
reference surface cancels the entire electro-acoustic chain along with $K_\mathrm{r}$
(Annex B). The 5 ms window bounds the sampled area (Annex A closed form:
radius ≈ 1.34 m for the standard geometry) and the valid range is
250 Hz – 4 kHz in one-third octaves.

![ISO 13472-1 in-situ road absorption by the subtraction technique: a loudspeaker at 1.25 m and a microphone at 0.25 m above the road surface, with the direct and road-reflected ray paths and a free-field reference measurement, the reflected component isolated by an Adrienne time window](https://docs.jmrp.io/phonometry/media/diagram_insitu_subtraction.svg)

### Spot method (ISO 13472-2)

Where Part 1 works at a stand-off of about a metre in the open, ISO 13472-2:2010
presses a small impedance tube against the surface, trading the 250 Hz – 4 kHz
range for 250–1600 Hz and a sample the size of the tube mouth. It defers the
mathematics to the ISO 10534-2 transfer-function method below (its
clauses 4/5.7/6.6); the implementation reuses that module, adding the Part 2
geometry and validity limits ($f_\mathrm{u} = 0.58\ c_0/d$; microphone spacing bounds
$0.45\ c_0/f_\mathrm{max}$ and $0.05\ c_0/f_\mathrm{min}$, clause 5.4) and the Annex A
subtractive correction for internal system losses.

See the [In-situ Road-Surface Absorption guide](https://docs.jmrp.io/phonometry/materials/surfaces/road-absorption/) for usage.

## Acoustic material characterisation (ISO 11654, ISO 9053-1/2, ISO 10534-1/2, ASTM E2611)

### Weighted sound absorption (ISO 11654)

ISO 11654:1997 condenses an ISO 354 third-octave absorption curve into a
single number. The practical coefficient $\alpha_\mathrm{p}$ averages the three thirds
of each octave 250 Hz – 4 kHz and rounds to steps of 0.05 (clause 4.1). The
reference curve (0.80, 1.00, 1.00, 1.00, 0.90 at 250–4000 Hz) is then shifted
downward in 0.05 steps until the sum of unfavourable deviations, counted only
where the measurement falls *below* the shifted curve, is $\le 0.10$;
$\alpha_\mathrm{w}$ is the shifted curve at 500 Hz (clause 4.2). A shape indicator
flags excess absorption $\ge 0.25$ above the shifted curve: L at 250 Hz, M at
500/1000 Hz, H at 2000/4000 Hz (clause 4.3), and the informative Annex B maps
$\alpha_\mathrm{w}$ to the absorption classes A–E. Because every quantity is a multiple
of 0.05, the implementation does the whole grid arithmetic in integer
twentieths, making the shift search and class boundaries exact and
float-safe. The two Annex A worked examples are reproduced:
$\alpha_\mathrm{p} = (0.35, 0.70, 0.65, 0.60, 0.55)$ → $\alpha_\mathrm{w} = 0.60$, class C; and
raising 500 Hz to 1.00 keeps $\alpha_\mathrm{w} = 0.60$ but adds the indicator, "0.60(M)".

![ISO 11654 weighted sound absorption rating: the practical absorption spectrum plotted against the shifted reference curve over 250 Hz to 4000 Hz, with the unfavourable deviation at 250 Hz shaded and the weighted coefficient alpha_w read at 500 Hz](https://docs.jmrp.io/phonometry/media/absorption_rating.svg)

*The ISO 11654 rating: practical absorption against the shifted reference, with the unfavourable deviation shaded and the weighted coefficient read at 500 Hz.*

See the [Sound Absorption Measurement and Rating guide](https://docs.jmrp.io/phonometry/materials/absorbers/absorption-measurement/) for usage.

### Airflow resistance (ISO 9053-1/2)

Airflow resistivity $\sigma = R\,A/d$ is the key transport parameter of a
porous absorber: the Delany-Bazley and Miki regressions predict a material's
complex impedance and wavenumber from $\sigma$ alone, and the
Johnson-Champoux-Allard model takes it as the first of its five parameters.
What governs absorption, though, is the resistance of the **whole layer**,
$R_\mathrm{s} = \sigma d$, against the characteristic impedance of air: a rigidly backed
layer works best for $\rho_0 c_0 \lesssim \sigma d \lesssim 4 \rho_0 c_0$, so a
50 mm blanket wants roughly 8 to 33 kPa·s/m², which is where commercial
absorbers cluster. Below that window the layer is acoustically transparent and
above it the wave reflects off the front face before the pores can do any work.
Since a rigidly backed layer still needs about a quarter wavelength of depth to
develop its absorption, no resistivity buys absorption at frequencies whose
quarter wavelength exceeds the depth available, which is why a thin, very
resistive layer is a worse low-frequency absorber than a thick, moderately
resistive one; the
[Airflow Resistance guide](https://docs.jmrp.io/phonometry/materials/absorbers/airflow-resistance/#4-what-the-resistivity-feeds)
draws the window and gives the material ranges.

ISO 9053-1:2018 (static method) drives a steady flow through
the specimen and fits $\Delta p = a\,u + b\,u^2$ through the origin
(clause 7.5); since $R_\mathrm{s} = \Delta p / u = a + b\,u$, the linear coefficient is
the zero-velocity specific resistance, reported at the reference velocity
$u = 0.5$ mm/s.

![ISO 9053-1 static-method airflow resistance: the measured pressure drop against linear airflow velocity, fitted with a through-origin quadratic, with the specific airflow resistance evaluated at the 0.5 mm/s reference velocity](https://docs.jmrp.io/phonometry/media/airflow_resistance.svg)

*The fit, and the single abscissa it is read at. The curve is slightly
super-linear because the $b\,u^2$ term is real, but the reported quantity is the
linear coefficient $a$ (the fit extrapolated back to zero velocity), evaluated
at the 0.5 mm/s reference velocity, which is why the reference velocity has to
be stated with any resistivity that is quoted.*

ISO 9053-2:2020 (alternating method) replaces the flowmeter
with a ~2 Hz piston and a microphone in a closed cavity (clause 8.7,
Formula 2):

$$
R = \kappa'\ \frac{p_\mathrm{s}}{2 \pi f V}\ \frac{h_\mathrm{t}}{h_\mathrm{s}}\ 10^{(L_{p\mathrm{s}} - L_{p\mathrm{t}})/20}
$$

Only a level *difference* enters, so the sound-level device needs no
absolute calibration. The effective exponent $\kappa'$ (Annex A,
Formula A.7) corrects the adiabatic $\kappa$ for wall heat conduction through
the thermal boundary layer $\delta_h = \sqrt{2 c_0 l_\mathrm{h} / \omega}$
(Formulae A.4/A.5; ISO 9053-2 writes it $b$, renamed here to keep it apart from
the quadratic fit coefficient above).
The Annex A.3 worked example (100 mm closed cylinder at 2 Hz:
$\delta_h = 1.83$ mm,
$\kappa' = 1.370 = 0.978\,\kappa$) is reproduced, and the validity guards of
Formula 3 (transfer ratio < 0.3) and Formula 4 (10 dB background margin) are
enforced.

See the [Airflow Resistance guide](https://docs.jmrp.io/phonometry/materials/absorbers/airflow-resistance/) for usage.

### Impedance tube (ISO 10534-1, ISO 10534-2, ASTM E2611)

A tube below its cut-on frequency ($f d < 0.58\ c_0$ circular,
$< 0.50\ c_0$ rectangular; microphone-spacing limits $f s < 0.45\ c_0$ and
$f > c_0/(20 s)$, where $s$ is the microphone spacing throughout this
subsection and not the scattering coefficient of the first section;
clauses 4.2–4.5) carries only plane waves, so the surface
reflection factor of a sample is fully observable. ISO 10534-2:1998
(transfer-function method: the clause and equation numbers here are that
edition's, and ISO 10534-2:2023 renumbers them) compares the measured
two-microphone transfer
function $H_{12}$ with the analytic incident and reflected ones
$H_\mathrm{I} = \mathrm{e}^{-j k_0 s}$, $H_\mathrm{R} = \mathrm{e}^{+j k_0 s}$ (Annex D) to give (clause 7,
Eq. 17):

$$
r = \frac{H_{12} - H_\mathrm{I}}{H_\mathrm{R} - H_{12}}\ \mathrm{e}^{2 j k_0 x_1}, \qquad
\alpha = 1 - |r|^2, \qquad \frac{Z}{\rho c_0} = \frac{1 + r}{1 - r},
$$

with the complex wavenumber's attenuation lower bound
$k_0'' = 1.94 \times 10^{-2} \sqrt{f}/(c_0 d)$ (Eq. A.18).

**$H_{12}$ as measured is not the $H_{12}$ this formula wants.** It carries the
amplitude and, far more damagingly, the phase mismatch of the two channels
(microphone, preamplifier and analyser channel together) and clause 7.5 requires
one of two corrections before anything above is evaluated: interchange the two
microphones for every specimen measurement and combine the two transfer
functions (7.5.1, Eq. 8), or measure a calibration factor $H_\mathrm{c}$ once, as the
geometric mean of the interchanged pair on an absorptive specimen, and divide it
out of every subsequent measurement (7.5.2, Eqs. 10 and 13), which is the route
`microphone_calibration_factor` and `apply_microphone_calibration` implement. It matters more
than it looks: the method infers a complex reflection factor from the small phase
difference between two positions a few centimetres apart, so at the
low-frequency end that difference is itself small and a residual channel phase
error of a fraction of a degree is indistinguishable from real specimen
reactance. The symptom is a low-frequency absorption curve that drifts below
zero or above unity and does not repeat between mountings.

The specimen mounting is part of the same contract (clause 6). The sample fits
snugly in the holder but is neither compressed nor squeezed until it bulges, its
edge is sealed against leaks, and its front face sits normal to the tube axis at
a position known to ±0.5 mm: the same tolerance the standard puts on the
reference plane's distance to the nearest microphone (7.1), because that
distance is $x_1$ in the formula above. An uneven back face is levelled with a
putty layer against the backing plate, since an unintended air gap turns a
porous layer into a resonant absorber and moves the whole curve; at least two
specimens are measured under identical mounting conditions, and more when the
material is laterally inhomogeneous. The two spacing bounds quoted above are
what force a wide-band measurement into two spacer positions.

![ISO 10534-2 two-microphone impedance tube: a loudspeaker radiating a plane wave down the tube, two microphones flush in the wall at spacing s and distance x1 from the specimen face, the test specimen against a rigid backing, and the incident and reflected waves](https://docs.jmrp.io/phonometry/media/diagram_impedance_tube.svg)

![ISO 10534-2 two-microphone tube result for a 50 mm porous absorber: the normal-incidence absorption coefficient rising from about 0.2 at 200 Hz towards 0.97 above 1 kHz, with the reflection-factor magnitude falling as its mirror image](https://docs.jmrp.io/phonometry/media/impedance_tube_result.svg)

*What the formula returns: $\alpha$ and $|r|$ for a 50 mm porous absorber over
the working band of a 100 mm tube. The two curves are the same information
($\alpha = 1 - |r|^2$), so the figure is really one measurement drawn twice, and
the rise with frequency is the layer thickness growing against the wavelength.*

ISO 10534-1:1996
(standing-wave-ratio method) is the closed-form classic:
$|r| = (\mathrm{SWR} - 1)/(\mathrm{SWR} + 1)$ from the max/min ratio
$\mathrm{SWR} = 10^{\Delta L/20}$ and the
phase from the first-minimum position (Eqs. 12–26); an SWR of 3 gives exactly
$|r| = 0.5$ and $\alpha = 0.75$. (The standard writes the ratio $s$; it is
spelled out here to keep it apart from the microphone spacing above.)
ASTM E2611-19 adds transmission: four
microphones decompose the up- and downstream fields into the $A, B, C, D$
waves (Eqs. 17–20) and a two-load (or symmetric one-load) solve yields the
specimen's 2×2 **transfer matrix** $[p; u]_0 = T\,[p; u]_d$ (Eqs. 16/22–24),
from which the anechoic-backing normal-incidence transmission loss is
(Eqs. 25/26)

$$
TL = 20 \log_{10} \frac{\left| T_{11} + T_{12}/\rho c + \rho c\ T_{21} + T_{22} \right|}{2},
$$

plus the hard-backed reflection coefficient
$r_{hb} = (T_{11} - \rho c\,T_{21})/(T_{11} + \rho c\,T_{21})$ (Eq. 27, written
$R$ there; renamed here because $R$ is the airflow resistance two subsections
above), the
material wavenumber $\arccos(T_{11})/d$ (Eq. 29) and the characteristic
impedance $\sqrt{T_{12}/T_{21}}$ (Eq. 30). The three standards deliberately
keep their own sign ansatz and temperature units (ISO in kelvin, ASTM in
Celsius), and near-singular load solves raise a warning. Since neither
standard prints a numeric example, the reference values are physics identities
that must hold exactly: the
analytic air-layer matrix ($\det T = 1$, $T_{11} = T_{22}$,
$TL = 0\ \text{dB}$, hard-backed $|r_{hb}| = 1$), synthetic round-trips that
recover a known $r$, and
two-load recovery of an asymmetric reciprocal specimen.

![ASTM E2611 four-microphone transmission-loss tube: a sound source, two microphones upstream and two downstream of the test specimen at spacings s1 and s2 and offsets l1 and l2, an adjustable termination for the two-load method, the upstream A and B and downstream C and D travelling waves, and the transfer matrix and transmission-loss relations](https://docs.jmrp.io/phonometry/media/diagram_astm_tube.svg)

![ASTM E2611 transfer-matrix quantities of a 50 mm porous layer: the normal-incidence transmission loss rising from about 6.6 dB at 200 Hz to over 9 dB at 1.6 kHz on the left axis, and the hard-backed absorption coefficient rising from 0.19 to about 0.97 on the right axis](https://docs.jmrp.io/phonometry/media/transfer_matrix_tl.svg)

*The same four-pole entries answering two different questions: how much sound
the free-standing layer lets through (the transmission loss above) and how much
the same layer absorbs once it is backed rigidly. A material can be a good
absorber and a poor barrier at once, which this pair makes plain.*

See the [Impedance Tube guide](https://docs.jmrp.io/phonometry/materials/absorbers/impedance-tube/) for usage.

## References

- **Allard, J. F., & Atalla, N. (2009).** *Propagation of sound in porous media: Modelling sound absorbing materials* (2nd ed.). Wiley. https://doi.org/10.1002/9780470747339
  ISBN 978-0-470-74661-5. The porous-material theory linking the airflow-resistance and impedance-tube quantities of the characterisation section.
- **ASTM International. (2019).** [*Standard test method for normal incidence determination of porous material acoustical properties based on the transfer matrix method*](https://store.astm.org/e2611-19.html) (ASTM E2611-19).
  The four-microphone transfer-matrix decomposition and its transmission loss. The edition implemented here; since revised as ASTM E2611-24 (https://store.astm.org/e2611-24.html).
- **Cox, T. J., & D'Antonio, P. (2017).** *Acoustic absorbers and diffusers: Theory, design and application* (3rd ed.). CRC Press. https://doi.org/10.1201/9781315369211
  ISBN 978-1-4987-4099-9. Absorber and diffuser measurement and design, by the authors behind the ISO 17497-2 diffusion-coefficient method.
- **International Organization for Standardization. (1998).** [*Acoustics — Determination of sound absorption coefficient and impedance in impedance tubes — Part 2: Transfer-function method*](https://www.iso.org/standard/22851.html) (ISO 10534-2:1998).
  The two-microphone transfer-function method of the impedance-tube section. Adopted in Europe as EN ISO 10534-2:2001; since revised as ISO 10534-2:2023 (https://www.iso.org/standard/81294.html).
- **International Organization for Standardization. (2004).** [*Acoustics — Sound-scattering properties of surfaces — Part 1: Measurement of the random-incidence scattering coefficient in a reverberation room*](https://www.iso.org/standard/31397.html) (ISO 17497-1:2004+A1:2014).
  The edition implemented here: the turntable scattering-coefficient method and its Annex A uncertainty chain.
- **International Organization for Standardization. (2012).** [*Acoustics — Sound-scattering properties of surfaces — Part 2: Measurement of the directional diffusion coefficient in a free field*](https://www.iso.org/standard/55293.html) (ISO 17497-2:2012).
  The free-field directional diffusion coefficient and its solid-angle area weighting.
- **International Organization for Standardization. (2018).** [*Acoustics — Determination of airflow resistance — Part 1: Static airflow method*](https://www.iso.org/standard/69869.html) (ISO 9053-1:2018).
  The static airflow-resistance method and its reference velocity.
- **Jiménez, N., Cox, T. J., Romero-García, V., & Groby, J.-P. (2017).** Metadiffusers: Deep-subwavelength sound diffusers. *Scientific Reports*, *7*, 5389. https://doi.org/10.1038/s41598-017-05710-5
  Open access. Deep-subwavelength panel diffusers whose slow-sound resonant slots reach the diffusion of a Schroeder or quadratic-residue diffuser in a fraction of the depth; co-authored with Cox, behind the ISO 17497-2 diffusion-coefficient method.
- **Jiménez, N., Groby, J.-P., Pagneux, V., & Romero-García, V. (2017).** Iridescent perfect absorption in critically-coupled acoustic metamaterials using the transfer matrix method. *Applied Sciences*, *7*(6), 618. https://doi.org/10.3390/app7060618
  Open access. A transfer-matrix-method tutorial for rigidly-backed resonant absorbers with the critical-coupling condition for perfect absorption, using the same layer machinery as the multilayer impedance-tube prediction here.
- **Jiménez, N., Romero-García, V., & Groby, J.-P. (2018).** Perfect absorption of sound by rigidly-backed high-porous materials. *Acta Acustica united with Acustica*, *104*(3), 396-409. https://doi.org/10.3813/AAA.919183
  The critical-coupling condition applied to a rigidly-backed layer of ordinary high-porosity absorber, connecting the porous-material models of the characterisation section to perfect single-frequency absorption.
