# Errata in ISO 9614

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-9614/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-9614/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-10-28T03:12:25Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 9614: 7 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 7 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on UNE-EN ISO 9614-1:2010 and ISO 9614-1:1993, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## UNE-EN ISO 9614-1:2010, clause 9.1 (the sign dropped from "signed magnitude" in translation)

- **Location:** clause 9.1, the symbol list under Formula (11)
  $P_i = I_{\mathrm{n}i} \cdot S_i$, of UNE-EN ISO 9614-1 (March 2010), which
  declares itself "la versión en español de la Norma Europea EN ISO
  9614-1:2009", the European adoption of ISO 9614-1:1993.
- **The print:** "$I_{\mathrm{n}i}$ es el **módulo** de la componente de la
  intensidad acústica normal medida en la posición $i$ sobre la superficie de
  medida". The ISO original reads "$I_{\mathrm{n}i}$ is the **signed
  magnitude** of the normal sound intensity component measured at position $i$
  on the measurement surface".
- **The problem:** *módulo* is the absolute value, so the qualifier that
  carried the sign is gone, and the sign is what the rest of the method turns
  on. The Spanish print then contradicts itself twice over. The same clause 9.1
  gives, two paragraphs below that line, the conversion to apply when the level
  of a position is written $(-)\,XX$ dB:
  $I_{\mathrm{n}i} = -I_0 \times 10^{XX/10}$, a negative $I_{\mathrm{n}i}$.
  Clause 3.6.1, which defines the very quantity Formula (11) computes, calls
  $I_{\mathrm{n}i}$ "la componente normal, **con su signo**, de la intensidad
  acústica medida en la posición $i$", and A.2.3 calls it "el **valor
  algebraico** de la componente de intensidad acústica normal". And clause 9.2
  makes $\sum_i P_i$ *being negative* the condition that puts a frequency band
  outside the method, which no sum of magnitudes and positive areas can ever
  be. Read as a magnitude the method loses the one thing measurement at
  discrete points is for: separating the energy leaving the source from the
  energy flowing back in through part of the surface, which is what $F_3$
  (Formulae (A.6) and (A.7)) and $F_4$ (Formulae (A.8) and (A.9)) are built to
  quantify from the algebraic mean of the same $I_{\mathrm{n}i}$.
- **Evidence:** the two prints of the same symbol list, set side by side, and
  the three Spanish clauses read against one another. PDF pages 10, 18 and 22
  (printed pp. 10, 18 and 22) of UNE-EN ISO 9614-1:2010; PDF page 12 (printed
  p. 7) of ISO 9614-1:1993, where the qualifier is present.
- **Library behaviour:** implements the signed reading throughout, which is the
  ISO text.
  [`sound_power_intensity_points`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/_sound_power_intensity_points.py)
  sums signed partial powers, flags the bands whose sum is not positive as
  outside the method, and reports $F_3 - F_2$ as the excess the inward flow
  produces; `normal_intensity_from_levels` carries the $(-)$ of the print as a
  separate argument, because the printed level never holds it. Pinned by
  `test_a_genuinely_negative_partial_power_is_kept_and_summed` and the signed
  conversion tests in
  [`tests/emission/test_sound_power_intensity_points.py`](https://github.com/jmrplens/phonometry/blob/main/tests/emission/test_sound_power_intensity_points.py).
- **Status:** unreported (national translation, not the issuing body's text: a
  reader working from the ISO edition has nothing to work around).

## UNE-EN ISO 9614-1:2010, clause A.2.3 (modulus bars on the algebraic intensity level)

- **Location:** Annex A, clause A.2.3, the "donde" list under Formula (A.6)
  $F_3 = \overline{L_p} - \overline{L_{I_\mathrm{n}}}$.
- **The print:** the second entry of the list is typeset
  $\overline{L_{|I_\mathrm{n}|}}$, with the absolute-value bars, and reads "es
  el valor algebraico del nivel de intensidad acústica superficial, en
  decibelios, calculado a partir de la ecuación (A.7)". Formula (A.7), three
  lines below on the same page, is labelled $\overline{L_{I_\mathrm{n}}}$,
  without the bars.
- **The problem:** the barred symbol is A.2.2's, the level of the mean
  *magnitude* of Formula (A.5), which is exactly what $F_2$ subtracts. With the
  bars, $F_3$ and $F_2$ would be the same indicator and the whole of A.2.3
  would be redundant; the sentence beside the symbol says "valor algebraico"
  and points at (A.7), which takes the algebraic mean. The ISO original prints
  the same entry without the bars and describes it as "the surface normal
  signed intensity level", so the bars are the translation's own typesetting.
- **Evidence:** the symbol as set in the two editions, and the barless (A.7) on
  the same page as the barred entry. PDF page 22 (printed p. 22) of UNE-EN ISO
  9614-1:2010; PDF page 15 (printed p. 10) of ISO 9614-1:1993.
- **Library behaviour:** none required. `field_indicators` in
  [`intensity.py`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/intensity.py) forms $F_3$ from
  the algebraic mean of Formula (A.7) and $F_2$ from the mean magnitude of
  Formula (A.5), which is what makes $F_3 - F_2$ the inward-flow excess the
  Annex B gate is written on. Registered as a label defect.
- **Status:** unreported (national translation, not the issuing body's text).

## ISO 9614-1:1993, clause B.1.3 ($F_4$ cross-referenced to A.2.3, which defines $F_3$)

- **Location:** Annex B, clause B.1.3, the sentence introducing the two
  separate evaluations of $F_4$ that Formula (B.4) consumes.
- **The print:** "Calculate indicator $F_4$ separately according to **A.2.3**",
  over the two items "a) for the segment subset $N_\alpha$ having total area
  $S_\alpha$, and" and "b) for the remaining segments". The Spanish edition
  renders the same clause number: "Calcular el indicador $F_4$ separadamente
  de acuerdo al apartado A.2.3 para: a) el subconjunto de segmentos $N_\alpha$
  con área total $S_\alpha$, y b) los segmentos restantes."
- **The problem:** A.2.3 is "Negative partial power indicator", which defines
  $F_3$ by Formulae (A.6) and (A.7). $F_4$ is A.2.4, "Field non-uniformity
  indicator", Formulae (A.8) and (A.9). Followed as printed, the reference
  computes the wrong indicator for $F_4(\alpha)$ and $F_4(1-\alpha)$, and those
  are what size the new positions in Formula (B.4). Both editions carry the
  same clause numbering, so the defect is the issuing body's.
- **Evidence:** the reference and the headings of A.2.3 and A.2.4 read against
  each other. PDF pages 18 and 15 to 16 (printed pp. 13 and 10 to 11) of ISO
  9614-1:1993; the same sentence at PDF page 24 (printed p. 24) of UNE-EN ISO
  9614-1:2010.
- **Library behaviour:** follows the intended target. $F_4(\alpha)$ and
  $F_4(1-\alpha)$ are computed per A.2.4 in
  [`partial_power_concentration`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/_sound_power_intensity_points.py).
  The reference changes no number the library reports, so no other change was
  needed.
- **Status:** unreported (cross-reference defect, no numerical consequence).

## UNE-EN ISO 9614-1:2010, clause 10.5 c) (an equation number replaced by a chapter that is not there)

- **Location:** clause 10.5 c), "Datos acústicos", the reporting requirement
  that accompanies the level of a band which does not satisfy criterion 2.
- **The print:** "Una referencia a la incertidumbre prevista en el nivel de
  potencia acústica determinada para cada banda de frecuencia en la que no se
  satisfaga el criterio 2 del anexo B, **de acuerdo a la ecuación (véase el
  capítulo B.3)**." The ISO original reads "A statement of the predicted
  uncertainty in the sound power level determined for each frequency band, in
  which criterion 2 of annex B is not satisfied, **according to equation
  (B.3)**."
- **The problem:** the number that identified the equation has been moved into
  a cross-reference and changed on the way. "De acuerdo a la ecuación ( )"
  names no equation, and what the parenthesis names instead is not part of the
  document: Annex B divides into B.1, with B.1.1 to B.1.5, and B.2, and stops
  there, so there is no chapter B.3 to look up. The requirement is unusable as
  printed unless the reader recognises Formula (B.3), the 95 % confidence
  interval $10 \lg (1 \pm 2 F_4 / \sqrt{N})$, which clause B.1.2 introduces
  with this very condition attached to it.
- **Evidence:** the two prints of the same item, and the divisions of Annex B
  as its headings run. PDF pages 20 and 23 to 26 (printed pp. 20 and 23 to 26)
  of UNE-EN ISO 9614-1:2010; PDF page 14 (printed p. 9) of ISO 9614-1:1993,
  where the equation number is present.
- **Library behaviour:** reports the interval of Formula (B.3) for every band,
  so the statement clause 10.5 c) asks for can be made about any band that
  needs it. `confidence_interval` on
  [`DiscretePointIntensityResult`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/_sound_power_intensity_points.py)
  carries the pair, and `criterion_2` says which bands the requirement applies
  to. The defect changes no number, only where a reader is sent to find the
  formula.
- **Status:** unreported (national translation, not the issuing body's text).

## ISO 9614-1:1993, Table B.3 (actions c and d both claim $F_3 - F_2 = 1$ dB)

- **Location:** Table B.3, "Actions to be taken to increase grade of accuracy
  of determination", the criterion cells of the action-c and action-d rows.
- **The print:** action c is conditioned on "Criterion 2 not satisfied and
  1 dB $\leq (F_3 - F_2) \leq$ 3 dB"; action d on "Criterion 2 not satisfied
  and $(F_3 - F_2) \leq$ 1 dB, and the procedure of 8.3.2 either fails or is
  not selected". Both inequalities are printed non-strict, in both editions.
- **The problem:** the two rows overlap at exactly $F_3 - F_2 = 1$ dB, where
  the table prescribes two different actions for one state: increase the
  density of positions uniformly (c), or move the surface out and keep the
  positions (d). A normative decision table is not implementable while that
  holds. The document settles it elsewhere: Figure B.1's fifth decision diamond
  is "$(F_3 - F_2) \leq$ 1 dB ?", and its **Yes** branch is the one that leads
  to the optional procedure and to action d, so 1 dB belongs to d and c begins
  above it. Clause 8.3.2 agrees, opening the optional procedure "if
  $F_3 - F_2 \leq$ 1 dB".
- **Evidence:** the two criterion cells, the diamond and its branches, and the
  clause 8.3.2 condition. PDF pages 19, 20 and 12 (printed pp. 14, 15 and 7) of
  ISO 9614-1:1993; the same three places at PDF pages 26, 27 and 17 (printed
  pp. 26, 27 and 17) of UNE-EN ISO 9614-1:2010.
- **Library behaviour:** follows Figure B.1 and clause 8.3.2. `required_actions`
  on
  [`DiscretePointIntensityResult`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/_sound_power_intensity_points.py)
  answers a band that fails criterion 2 with action c above 1 dB and action d
  at 1 dB and below, pinned at the boundary itself by
  `test_action_d_is_the_action_at_exactly_one_decibel` in
  [`tests/emission/test_sound_power_intensity_points.py`](https://github.com/jmrplens/phonometry/blob/main/tests/emission/test_sound_power_intensity_points.py).
- **Status:** unreported.

## ISO 9614-1:1993, equations (A.1) and (A.8) (the normalizing intensity without its overbar)

- **Location:** Annex A, clause A.2.1, equation (A.1) for the temporal
  variability indicator $F_1$, and clause A.2.4, equation (A.8) for the field
  non-uniformity indicator $F_4$.
- **The print:** both equations open with the factor $1/I_\mathrm{n}$, an
  unbarred symbol, while the deviation inside the sum is written against a
  clearly overbarred $\overline{I_\mathrm{n}}$:
  $F_1 = \frac{1}{I_\mathrm{n}} \sqrt{\frac{1}{M-1}\sum_k (I_{\mathrm{n}k} -
  \overline{I_\mathrm{n}})^2}$ and
  $F_4 = \frac{1}{I_\mathrm{n}} \sqrt{\frac{1}{N-1}\sum_i (I_{\mathrm{n}i} -
  \overline{I_\mathrm{n}})^2}$. Both editions set them the same way.
- **The problem:** the symbol lists that follow define only the overbarred one
  ("$\overline{I_\mathrm{n}}$ is the mean value of $I_\mathrm{n}$ for $M$
  short-time-average samples", A.2.1; "$\overline{I_\mathrm{n}}$ is the surface
  normal sound intensity calculated from equation (A.9)", A.2.4). The unbarred
  $I_\mathrm{n}$ is clause 3.4's normal intensity at a point, so as printed a
  coefficient of variation is divided by an unspecified single value rather
  than by the mean its own numerator is taken about. Both indicators are
  coefficients of variation and admit no other normalization.
- **Evidence:** the two equations and the symbol lists beneath them, where the
  bar is absent above the divisor and unbroken above the symbol inside the sum.
  PDF pages 15 and 16 (printed pp. 10 and 11) of ISO 9614-1:1993; the same two
  equations at PDF pages 21 and 22 (printed pp. 21 and 22) of UNE-EN ISO
  9614-1:2010.
- **Library behaviour:** none required. The coefficient of variation behind
  `field_indicators` and `temporal_variability_indicator` in
  [`intensity.py`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/intensity.py) divides by the
  algebraic mean, and refuses a mean that is not positive rather than dividing
  by it. Registered as a typographic defect.
- **Status:** unreported (typographic).

## UNE-EN ISO 9614-1:2010, Note 11 to clause B.1.3 (half a level, and a recommendation made a requirement)

- **Location:** Note 11, immediately after the Formula (B.4) block of clause
  B.1.3, which qualifies the choice of the Table B.2 factor $C$ for an
  A-weighted determination.
- **The print:** "Si la contribución total al **nivel de** potencia acústica
  ponderado A de las bandas de tercio de octava en el margen de frecuencias de
  800 Hz a 5 000 Hz es menos de la mitad del **nivel total**, entonces **deben**
  usarse los valores de $C$ para las bandas de tercio de octava de 200 Hz a
  630 Hz." The ISO original reads "If the total contribution to the A-weighted
  sound **power** from the one-third-octave bands in the frequency range 800 Hz
  to 5 000 Hz is less than half the total **power**, then the values of $C$ for
  the one-third-octave band 200 Hz to 630 Hz **should** be used."
- **The problem:** two departures in one sentence. Half of a *level* is not a
  defined operation, so the Spanish print states a condition that cannot be
  evaluated as written; the original conditions on half the *power*, which is a
  contribution 3 dB or more below the total and is decidable. And *should*, a
  recommendation under the ISO/IEC drafting rules, becomes *deben*, which reads
  as a requirement, so the two prints do not even agree on whether the
  substitution is optional.
- **Evidence:** the two prints of the same note. PDF page 25 (printed p. 25) of
  UNE-EN ISO 9614-1:2010; PDF page 18 (printed p. 13) of ISO 9614-1:1993.
- **Library behaviour:** implements the power reading, and applies the
  substitution whenever the condition holds rather than leaving it to the
  caller, which satisfies both prints. `_a_weighted_factor` in
  [`_sound_power_intensity_points.py`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/_sound_power_intensity_points.py)
  compares the summed A-weighted contribution of the 800 Hz to 5 kHz bands with
  half the total contribution and reads the 200 Hz to 630 Hz row of Table B.2
  when it falls short.
- **Status:** unreported (national translation, not the issuing body's text).