# Errata in ISO 9613

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-9613/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-9613/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 9613: 1 defect in the printed text, with the evidence and what phonometry does about it.

---

This is the entry of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 9613-2:1996. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 9613-2:1996, Table 2 (15 °C / 80 % / 1 kHz cell)

- **Location:** Table 2, "Atmospheric attenuation coefficient α for octave
  bands of noise", row 15 °C / 80 % relative humidity, column 1 kHz.
- **The print:** $\alpha = 4{,}1\ \text{dB/km}$.
- **The problem:** Table 2 is a rounded extract of ISO 9613-1, to which the
  clause itself defers ("For values of α at atmospheric conditions not covered
  in table 2, see ISO 9613-1"). Evaluating the ISO 9613-1 pure-tone formula at
  1 kHz, $15\ ^\circ\text{C}$, $80\ \%$ RH and $101.325\ \text{kPa}$ gives
  $4.1511\ \text{dB/km}$, which rounds to $4.2$, not the printed $4.1$.
  The neighbouring cells of the same row round correctly (2 kHz: $8.338$ ->
  printed $8.3$; 4 kHz: $23.86$ -> $23.7$ at the exact band centre), as
  do the 1 kHz cells of the other rows ($15\ ^\circ\text{C}$ / $50\ \%$:
  $4.164$ -> printed $4.2$), so the defect is confined to this cell.
- **Evidence:** independent evaluation of the ISO 9613-1 coefficient at both
  the nominal and the exact band-centre frequency ($4.1511\ \text{dB/km}$
  either way, 1 kHz being both).
- **Library behaviour:** unaffected. The library never reads Table 2: it
  computes $A_\text{atm}$ from the ISO 9613-1 formula directly
  ([`air_absorption.py`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/environment/propagation/air_absorption.py)),
  so it yields $4.15\ \text{dB/km}$ for this condition.
- **Status:** unreported.