# Errata in ISO 15186

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-15186/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-15186/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 15186: 2 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 2 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 15186-1 and ISO 15186-3:2002, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 15186-1, Clause 3.9, Formula (8) (sign of the 10 lg N term)

- **Location:** Clause 3.9, Formula (8) (printed p. 3), the intensity element
  normalized level difference for N small building elements measured together.
  The print read here is **BS EN ISO 15186-1:2003**, the identical-text
  British adoption; the entry previously carried the heading ":2000", the year
  of the ISO edition the library's docstrings cite, which is not the copy that
  was read.
- **The print:**
  $D_{I,n,e} = L_{p1} - 6 - (L_{In} + 10 \lg(S_m/A_0) + 10 \lg(N))$, i.e. the
  $10 \lg N$ term is subtracted.
- **The problem:** the subtracted sign cannot be derived. Measuring $N$
  identical units within one measurement surface raises the transmitted power
  (and hence $L_{In} + 10\log_{10} S_m$) by $10\log_{10} N$, so recovering the
  per-unit $D_{I,n,e}$ requires *adding* $10\log_{10} N$. The pressure-based
  equivalent, ISO 10140-2:2010 Formula (6), prints exactly that correction
  ($D_{n,e} = L_1 - L_2 + 10\log_{10}(nA_0/A)$), and ISO 15186-2:2010 Formula
  (12) prints Formula (8) without any $N$ term (the $N = 1$ case, with which
  both signs agree). As printed, installing more units would *lower* the
  per-unit rating by $20\log_{10} N$ relative to the derivable value.
- **Evidence:** derivation from the diffuse-field receiving-room relation
  $L_2 = L_W + 10\log_{10}(4/A)$ against ISO 10140-2:2010 Formula (6);
  cross-check against ISO 15186-2:2010 Formula (12) and Hopkins, *Sound
  Insulation* (2007), Eq. 3.45. Verified on PDF page 11 (printed p. 3) of BS
  EN ISO 15186-1:2003, with the cross-check read on PDF page 11 (printed p.
  11) of ISO 10140-2:2010. **Part 3 of the same series settles it in the
  series' own words:** ISO 15186-3:2002, Clause 3.9, Formula (8) states the
  same quantity as
  $D_{I,n,e} = L_{pS} - 9 - [L_{In} - 10 \lg(A_0/S_m) - 10 \lg N]$, whose
  bracket carries $10 \lg N$ with the opposite outer sign, i.e. the
  $+10\log_{10} N$ derived here. Read on PDF page 10 (printed p. 4) of BS EN
  ISO 15186-3:2010.
- **Library behaviour:** implements the derivable per-unit form
  (`intensity_element_normalized_difference`, $+10\log_{10} N$) and emits a
  warning whenever $n > 1$, where the result deviates from the print.
- **Status:** unreported.

## ISO 15186-3:2002, Annex A, Table A.1 (steel-sandwich column irreproducible from its own inputs)

- **Location:** Annex A (normative), A.2 and Table A.1, "Calculated sound
  reduction index (at 1 013 hPa and 23 °C)", the qualification example a
  laboratory checks its facility against. The print read here is **BS EN ISO
  15186-3:2010**, the identical-text British adoption of ISO 15186-3:2002,
  PDF page 18 (printed p. 12).
- **The print:** two columns of six one-third-octave values, 50 Hz to 160 Hz.
  The plaster-board column is headed "$10\ \text{kg/m}^2$" over a "Test opening $10\ \text{m}^2$"
  and reads 10,7 / 11,9 / 13,4 / 14,8 / 16,3 / 17,9. The steel column is
  headed "$17\ \text{kg/m}^2$" over a "Test opening 1,25 m × 1,50 m" and reads
  21,3 / 21,2 / 21,7 / 22,7 / 23,8 / 25,1. A.2 also states that "the
  dimensions of the free part of the panel are 1,162 m × 1,412 m".
- **The problem:** no reading of the inputs printed beside the steel column
  reproduces it. With the test opening ($1.875\ \text{m}^2$) and the stated mass, the six
  computed values fall 1.27 dB to 0.72 dB below the printed ones. The 0.55 dB
  spread between those two ends rules out any surface mass at that area,
  because a mass error shifts $R_0 = 20 \lg(\pi f m / \rho c)$ by the same amount
  in every band. With the free part of the panel ($1.640744\ \text{m}^2$) the residual is
  nearly flat, mean 0.562 dB, but it still spreads 0.102 dB end to end, which
  is the whole width of the printed decimal, so it is not the constant offset a
  wrong mass alone would leave either.

  No single input closes it to the 0.05 dB that one-decimal printing allows.
  The best surface mass alone, over the free part, is $18.13\ \text{kg/m}^2$ and leaves
  0.051 dB; the best static pressure alone is 950 hPa and leaves 0.051 dB; the
  best temperature alone, over the test opening, is 63 °C and leaves 0.052 dB.
  The last two contradict the caption, which fixes the climate at 1 013 hPa and
  23 °C, and the plaster-board column reproduces at exactly that climate, so the
  two columns cannot be read at different ones.

  The only reading that does reproduce all six values moves two inputs at once:
  an area of about $1.654\ \text{m}^2$, near the free part but not equal to it, together
  with a surface mass of about $18.16\ \text{kg/m}^2$. That mass is not available to the
  specimen described. Solid steel 2.2 mm thick is $16.9\ \text{kg/m}^2$ to $17.3\ \text{kg/m}^2$, and
  the leaf is a steel/resin/steel sandwich, so its surface mass is necessarily
  below that. The plaster-board column of the same table, from the same
  formulas at the same climate, reproduces all six of its values to within
  0.050 dB.
- **Evidence:** Formulas (A.1) to (A.5) evaluated at the stated 1 013 hPa and
  23 °C, read on PDF pages 17 and 18 (printed pp. 11 and 12) of BS EN ISO
  15186-3:2010. ISO 140-3:1995, C.2.4, which A.2 cites as the source of the
  specimen, describes the 2.2 mm steel/resin/steel leaf but states no surface
  mass, so the $17\ \text{kg/m}^2$ is not carried over from there. No corrigendum to
  Annex A was found.
- **Library behaviour:** `limp_panel_reduction_index` implements Formulas
  (A.1) to (A.5) as printed. The conformance suite anchors them on the
  plaster-board column alone; the steel column is deliberately not used as an
  oracle.
- **Status:** unreported.
