# Errata in ISO 12999

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-12999/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-12999/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-10-28T03:12:25Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 12999: 3 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 3 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 12999-1:2020 and ISO 12999-2:2020, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 12999-1:2020, Table 4 (missing 500 Hz row)

- **Location:** Table 4 (in-situ uncertainties per band).
- **The print:** the 2020 edition's table omits the 500 Hz row that the 2014
  edition prints (situation B 1,2 dB / situation C 0,8 dB).
- **The problem:** likely an editorial omission; the surrounding rows are
  unchanged between editions and the text does not mention removing the band.
- **Evidence:** side-by-side comparison of the 2014 and 2020 prints.
- **Library behaviour:** follows the 2020 print as published, with the
  omission documented in the module.
- **Status:** unreported.

## ISO 12999-2:2020, Clause 8 wording vs Tables 4 and 5

- **Location:** Clause 8 **"Reporting uncertainties"** (printed pp. 5-6), the
  where-list under Formula (10), against the worked Tables 4 and 5 (printed p.
  7). An earlier revision of this entry called the clause "expression of
  results", which is not its printed title.
- **The print:** the where-list defines $u$ as "the standard uncertainty
  determined in accordance with Clause 5, Clause 6 or Clause 7 **rounded to
  two decimal digits for absorption coefficients** or one decimal digit for
  all other quantities", and Formula (10) then forms $U = k \cdot u$.
- **The problem:** the document's own Tables 4 and 5 only reproduce when $U$
  is computed from the unrounded $u$ and rounded last. Neither table prints a
  $u$ column at all (each has only the coefficient $\alpha_s$ or $\alpha_p$
  and $\pm U$ with $k = 2$), so the printed $U$ values are the whole of the
  evidence, and 11 of the 25 are unreachable under the literal clause wording.
- **Evidence:** recomputation of all 25 entries (Table 4: 20 rows, Table 5: 5
  rows) from Formula (1) with the Table 1 constants and from Formula (4) with
  the Table 2 constants, under both conventions. Round-last reproduces 25 of
  25; round-first misses 11 of 25 (63, 125, 160, 200, 250, 1250, 1600, 2000,
  3150 and 4000 Hz of Table 4, and 250 Hz of Table 5). An earlier revision of
  this entry quoted the count as "10 of 20", which is neither the right
  numerator nor the right number of entries. Verified on PDF pages 9 (printed
  p. 3), 10 (printed p. 4), 11 (printed p. 5) and 13 (printed p. 7) of ISO
  12999-2:2020.
- **Library behaviour:** rounds last, matching the tables; the convention is
  documented and tested.
- **Status:** unreported.

## ISO 12999-2:2020, Table 5 (octave-band data under a one-third-octave header)

- **Location:** clause 8, Table 5 "Example for the practical sound absorption
  coefficient, αp, and its expanded uncertainty under reproducibility
  conditions" (printed p. 7).
- **The print:** the frequency column of Table 5 is headed **"One-third octave
  midband frequency / Hz"** and its rows are 250, 500, 1 000, 2 000 and 4 000
  Hz.
- **The problem:** those five frequencies are the **octave**-band series of
  ISO 11654, which is what the practical sound absorption coefficient
  $\alpha_p$ is defined over; they are not a one-third-octave series, and no
  one-third octave band is missing between them. The document contradicts
  itself on the same quantity two pages earlier: Table 2, which supplies the
  $m$ and $n$ constants of Formula (4) for exactly these five frequencies, is
  headed "Octave midband frequency". The same header text stands over Table 4
  on the same page, where it is correct: that table carries a genuine
  one-third-octave series, 63 Hz to 5 000 Hz in 20 rows.
- **Evidence:** the five tabulated frequencies themselves, and the "Octave
  midband frequency" header of Table 2 for the same $\alpha_p$ constants.
  Verified on PDF page 13 (printed p. 7) and PDF page 11 (printed p. 5) of ISO
  12999-2:2020.
- **Library behaviour:** `_TABLE2` in
  [`uncertainty.py`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/materials/absorbers/uncertainty.py) is
  keyed by *octave* midband frequency, following Table 2 and the ISO 11654
  definition of $\alpha_p$ rather than the Table 5 header.
- **Status:** unreported.