# Errata in ISO 10052

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-10052/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-10052/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-10-28T03:12:25Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 10052: 1 defect in the printed text, with the evidence and what phonometry does about it.

---

This is the entry of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 10052:2021. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 10052:2021, Table 4 volume-range header

- **Location:** Table 4 (reverberation-index estimator), volume-range header.
- **The print:** the header reads "60 ≤ V < 150" while the body text says the
  method applies to rooms "up to $150\ \text{m}^3$".
- **The problem:** the boundary $V = 150\ \text{m}^3$ is included by the text
  and excluded by the header.
- **Evidence:** direct comparison of header and clause text.
- **Library behaviour:** accepts $V = 150$ (follows the text), with the
  ambiguity noted.
- **Status:** unreported.