# Errata in published sources

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Defects in the standards, guidance and textbooks the library uses: misprints, worked examples contradicting their own clauses, and how each is handled.

---

Implementing a standard clean-room means re-deriving every formula, constant
and worked example from the source document rather than from anyone else's
code. Done across hundreds of documents, that process finds defects in the
sources themselves: a worked example that contradicts its own normative
clause, a constant with a digit dropped in typesetting, a cross-reference that
points at the wrong equation.

This is the registry of those findings. It covers every kind of published
source the library implements from: standards (ISO, IEC, EN), guidance
documents and technical reports (EASA, ECAC, NRL), textbooks and journal
papers. Non-normative sources are marked as such in their entry.

Each entry names the printed edition and the exact location, quotes what the
document says, shows why it cannot be right, gives the independent evidence,
and states which reading the library implements. Where that reading changes a
number the library reports, the entry names the check or regression test that
pins it; where the defect is a label, a cross-reference or a table the library
never reads, the entry records that no change was required. A defect listed
here is never a defect of the *method*: in every case the intended reading
could be established from the document itself or from physics.

Read it alongside the [conformance report](https://docs.jmrp.io/phonometry/reference/conformance/),
which shows the numbers the library computes; the registry explains the
handful of places where the printed expected value is the thing that is wrong.

Each entry lives on the page of the document it is about, one page per
document family: every part and edition of ISO 3743 on one page, a book on a
page named after its authors. Every entry is listed below under its document.
A link to an entry written as `/reference/errata/#entry`, from before the
registry was split, still lands on it.

The registry is maintained in
[`docs/ERRATA.md`](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md)
and its entries are transplanted into these pages at build time by
`make site-reports`, so the two cannot disagree.

Status legend: **unreported** (recorded here only) / **reported** (submitted
to the issuing body, with date and reference).

A claim that turns on the exact characters of a formula, constant,
coefficient, symbol, inequality or table cell is verified against **the page
as printed**, and its Evidence bullet cites that page by PDF page index and
printed folio. Extracted text may locate a page; it is never quoted as "the
print", because PDF text layers delete glyphs silently (most of the sources
cited here emit no `√` at all, so `f_T/√2` extracts as `f_T/2`). The page
offset of each document is established empirically, because it differs per
document and drifts between chapters of the same book. Entries that rest on
something else, a recomputation or a comparison of two sentences, say so
either in a leading notice or on the allowlist of
[`scripts/check_errata_evidence.py`](https://github.com/jmrplens/phonometry/blob/main/scripts/check_errata_evidence.py),
which is the check that enforces the rule; see
[CONTRIBUTING.md](https://github.com/jmrplens/phonometry/blob/main/CONTRIBUTING.md#6-filing-an-errata-entry).

A Spanish edition of this registry, translated entry for entry, is maintained
in [ERRATA.es.md](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.es.md). The wording here is the authoritative one,
and quoted print, mathematics and printed values are reproduced there
untranslated; `make site-reports` holds the two editions to the same entries
in the same order.

## Standards

One page per series, which gathers its parts, its editions and its national adoptions.

### [ISO 717](https://docs.jmrp.io/phonometry/reference/errata/iso-717/) (3 entries)

- ISO 717-2:2020, Annex C, example C.1 (CI of the bare floor)
- ISO 717-2:2020, Annex C, example C.2 (covered floor: 800 Hz value and CI chain)
- ISO 717-1:2020, Annex E, Figures E.3 and E.2 (reference curves drawn off Table E.1)

### [ISO/PAS 1996](https://docs.jmrp.io/phonometry/reference/errata/iso-1996/) (1 entry)

- ISO/PAS 1996-3:2022, Clause 5 (cross-references of r and d)

### [ISO 2631](https://docs.jmrp.io/phonometry/reference/errata/iso-2631/) (1 entry)

- ISO 2631-5:2018, Annex C worked examples (male displayed formula, female R)

### [ISO 3095](https://docs.jmrp.io/phonometry/reference/errata/iso-3095/) (3 entries)

- ISO 3095:2013, Table G.1 (the standard uncertainty of the 25 m microphone distance printed as 0.004 dB)
- ISO 3095:2013, Table G.1 against Table G.2 (the ground-level uncertainty at 7.5 m printed as 0.55 dB in one and 0.30 dB in the other)
- ISO 3095:2013, Table G.1 (the wind screen interval printed with its bounds out of order)

### [ISO 3382](https://docs.jmrp.io/phonometry/reference/errata/iso-3382/) (5 entries)

- ISO 3382-1:2009, A.2.1 (the same symbol names two different levels, a page apart)
- ISO 3382-1:2009, A.2.1 (a directivity survey "at every 12,5 degrees" that does not close the circle)
- ISO 3382-1:2009, C.2.1 and C.2.2 (the prose of both stage supports leaves out an integration limit)
- ISO 3382-1:2009, Table 1 and A.4 (the same limits are called maximum in one clause and minimum in the other)
- ISO 3382-1:2009, 4.2.1 (a gliding average whose window has no stated phase)

### [ISO 3743](https://docs.jmrp.io/phonometry/reference/errata/iso-3743/) (15 entries)

- ISO 3743-1:2010, 9.1, Equation (21) (the total standard deviation written $\sigma_\mathrm{TO}$)
- ISO 3743-1:2010, Table 3 (a one-third-octave range under an octave heading)
- ISO 3743-1:2010, C.4.2.5 (the altitude correction of another standard)
- ISO 3743-1:2010, C.4.2.8 and C.4.2.9 (the humidity band of ISO 3741 quoted at 30 % instead of 50 %)
- ISO 3743-2:2018, D.4.2.5 (the altitude correction of another standard)
- ISO 3743-2:2018, 11.3.2, Formula (14) (the total and the operating deviation added instead of subtracted)
- ISO 3743-2:2018, D.4.2.4 and D.4.2.12 (a background contribution that is not the product it names, and a budget that does not use it)
- ISO 3743-2:2018, D.4.2.11 and Table D.2 (a reverberation-time coefficient that is the derivative of neither)
- ISO 3743-2:2018, Formula (D.1) (a sum that starts at $j = i$)
- ISO 3743-2:2018, D.4.2.8 (the frequency of the formula defined as $F$)
- ISO 3743-2:2018, 3.1 (the designation written "ISO ISO 3743-2")
- ISO 3743-2:2018, 6.3, Figure 1 (a curve that runs above Formula (1) at the low end)
- ISO 3743-2:2018, Figure B.3 (the limiting curves widened at 6.3 kHz, where 6.3 widens them above it)
- ISO 3743-2:2018, B.5, EXAMPLE (a centring that puts the curve of Figure B.4 outside the limits)
- ISO 3743-2:2018, F.1 (Annex F tied to the direct method while 10.4 sends the comparison method to it)

### [ISO 3744](https://docs.jmrp.io/phonometry/reference/errata/iso-3744/) (3 entries)

- ISO 3744:2010, 8.3.4, Equation (21) (a time-integrated level compared with a time-averaged one)
- ISO 3744:2010, 8.3.4 (the correction named K_1i in the text and K_1 in Equation (21))
- ISO 3744:2010, H.4.2.7 (the altitude correction and the divisor under it)

### [ISO 3745](https://docs.jmrp.io/phonometry/reference/errata/iso-3745/) (1 entry)

- ISO 3745:2012/Amd.1:2017, A.2.4 against A.4.3 (two spatial resolutions for one traverse)

### [ISO 3747](https://docs.jmrp.io/phonometry/reference/errata/iso-3747/) (5 entries)

- ISO 3747:2010, E.4.2.6.2 (the sign of the direct-field level)
- ISO 3747:2010, E.4.2.5 (the altitude correction quoted against Annex C)
- ISO 3747:2010, Table E.2 (the excess that lost its delta)
- ISO 3747:2010, Table E.2 (the sampling coefficient its own clause contradicts)
- ISO 3747:2010, E.4.2.3 (the equation the derivative is taken of)

### [ISO 3891](https://docs.jmrp.io/phonometry/reference/errata/iso-3891/) (1 entry)

- ISO 3891:1978, Annex A, Table 9 (seven cells a unit above Table 10 where the humidity drops out)

### [ISO 4869](https://docs.jmrp.io/phonometry/reference/errata/iso-4869/) (3 entries)

- ISO 4869-2:2018, Table C.1 (the reprint that disagrees with the table it reprints)
- ISO 4869-6:2019, Table A.3 (the uncertainty rows are formed from the rounded row above them)
- ISO 4869-3:2007, 5.2.2 and Table 1 (a microphone index of exactly 5 dB in two rows)

### [ISO 5136](https://docs.jmrp.io/phonometry/reference/errata/iso-5136/) (8 entries)

- ISO 5136:2003, Table A.5, 5 000 Hz row (the leading digit of $a_3$ is missing)
- ISO 5136:2003, Annex D, Annex H and Annex I ($C_{3,4}$ "according to Equation (3)")
- ISO 5136:2003, Annex B, B.2 step 4 ($\Delta L_{\max}$ "given in Table C.1")
- ISO 5136:2003, Annex B, B.1 ("the determination of the combined mean flow velocity")
- ISO 5136:2003, clause 7.4 NOTE (the "hydraulic diameter" $D_\mathrm{h} = \sqrt{S_{\mathrm{f}2}/\pi}$)
- ISO 5136:2003, Table A.2, coefficient header (the $a_9$ column heads $a9_0$)
- ISO 5136:2003, Table A.6, 16 000 Hz row ($a_1$ printed with a doubled multiplication sign)
- ISO 5136:2003, Table I.2 (continued), 20 000 Hz row (the exponents of $a_8$ and $a_9$)

### [ISO 6926](https://docs.jmrp.io/phonometry/reference/errata/iso-6926/) (1 entry)

- ISO 6926:2016, Annex A, Formula (A.1) (d_0 as half of a length ISO 3745 already halves)

### [ISO 7235](https://docs.jmrp.io/phonometry/reference/errata/iso-7235/) (1 entry)

- ISO 7235:2003, Table 6 (the 160 Hz band belongs to no row)

### [ISO 8041](https://docs.jmrp.io/phonometry/reference/errata/iso-8041/) (4 entries)

- ISO 8041-1:2017, clause 12.7 ("the appropriate weighting factor (see Table 1)" for `Wf`)
- ISO 8041-2:2021, clause 12.7 ("the appropriate weighting factor (see Table 1)" for `Wf`, carried over from Part 1)
- ISO 8041-2:2021, clause 12.7 (time weightings graded against a row Table 2 no longer prints)
- ISO 8041-2:2021, clause 12.22 ("exited" for "excited")

### [ISO 8253](https://docs.jmrp.io/phonometry/reference/errata/iso-8253/) (4 entries)

- ISO 8253-1:2010, 11.1 (the filter standard cited as IEC 61620)
- ISO 8253-1:2010, Table 3, footnote a (the earphone names marked with the diffuse-field footnote)
- ISO 8253-1:2010, A.3.6 (a misspelt word in the masking-noise uncertainty)
- ISO 8253-2:2009, Annex B (Table B.1 announced from 200 Hz, printed from 125 Hz)

### [ISO 8297](https://docs.jmrp.io/phonometry/reference/errata/iso-8297/) (4 entries)

- ISO 8297:1994, 3.7 (a misspelt term in the heading of the definition)
- ISO 8297:1994, 9.1.1 b) (the aspect angle written with the symbol of the microphone's 3 dB angle)
- ISO 8297:1994, 10.4 (the area term written with a lower-case subscript)
- ISO 8297:1994, Table 3 (the 31.5 Hz octave printed as 31 Hz)

### [ISO 9053](https://docs.jmrp.io/phonometry/reference/errata/iso-9053/) (1 entry)

- ISO 9053-2:2020, Annex A.3 (two air properties credited to a document that does not print them)

### [ISO 9295](https://docs.jmrp.io/phonometry/reference/errata/iso-9295/) (2 entries)

- UNE-EN ISO 9295:2015, Tables 1 and 2 (forty-three cells where a 0 of Annex A is printed as another digit)
- UNE-EN ISO 9295:2015, Formula (A.5) (the oxygen relaxation frequency set with a digit zero)

### [ISO 9613](https://docs.jmrp.io/phonometry/reference/errata/iso-9613/) (1 entry)

- ISO 9613-2:1996, Table 2 (15 °C / 80 % / 1 kHz cell)

### [ISO 9614](https://docs.jmrp.io/phonometry/reference/errata/iso-9614/) (7 entries)

- UNE-EN ISO 9614-1:2010, clause 9.1 (the sign dropped from "signed magnitude" in translation)
- UNE-EN ISO 9614-1:2010, clause A.2.3 (modulus bars on the algebraic intensity level)
- ISO 9614-1:1993, clause B.1.3 ($F_4$ cross-referenced to A.2.3, which defines $F_3$)
- UNE-EN ISO 9614-1:2010, clause 10.5 c) (an equation number replaced by a chapter that is not there)
- ISO 9614-1:1993, Table B.3 (actions c and d both claim $F_3 - F_2 = 1$ dB)
- ISO 9614-1:1993, equations (A.1) and (A.8) (the normalizing intensity without its overbar)
- UNE-EN ISO 9614-1:2010, Note 11 to clause B.1.3 (half a level, and a recommendation made a requirement)

### [ISO 10052](https://docs.jmrp.io/phonometry/reference/errata/iso-10052/) (1 entry)

- ISO 10052:2021, Table 4 volume-range header

### [ISO 10140](https://docs.jmrp.io/phonometry/reference/errata/iso-10140/) (3 entries)

- ISO 10140-1:2021, Annex H, Figure H.4 (a CI,r,50-2500 the reference floor cannot give)
- ISO 10140-1:2021, Annex J, Figure J.7 ("weighing curve" for "weighting curve")
- ISO 10140-1:2021, Annex J, Figure J.8 (the working range drawn as Δb and keyed as Δbn)

### [ISO 10846](https://docs.jmrp.io/phonometry/reference/errata/iso-10846/) (2 entries)

- ISO 10846-2:2008, 7.6.1 (the unidirectionality pre-run cross-referenced to 6.1, Inequality (1))
- ISO 10846-4:2003, 6.2 NOTE 1 (the bound of Inequality (3) printed as 05 dB)

### [ISO 10847](https://docs.jmrp.io/phonometry/reference/errata/iso-10847/) (2 entries)

- ISO 10847:1997, Table 1 (an upwind class printed with a positive lower bound)
- ISO 10847:1997, 8.2.2 (one prime asked to mean two different things)

### [ISO 10848](https://docs.jmrp.io/phonometry/reference/errata/iso-10848/) (1 entry)

- ISO 10848-1:2006, Clause 8.1.1, Formula (20) (spurious π in the critical frequency)

### [ISO 11200](https://docs.jmrp.io/phonometry/reference/errata/iso-11200/) (1 entry)

- ISO 11200:2014, Annex B (the two case studies compute the same standard deviation two different ways)

### [ISO 11546](https://docs.jmrp.io/phonometry/reference/errata/iso-11546/) (6 entries)

- ISO 11546-1:1995, 9.4 c) (a quantity cross-referenced to the uncertainty clause)
- ISO 11546-1:1995, clause 8 (a misspelt word in the uncertainty statement)
- ISO 11546-2:1995, Annex C, Table C.1 (a column headed with a standard that does not exist)
- ISO 11546-2:1995, definition 3.11 (an estimate that points at the wrong annex)
- ISO 11546-2:1995, Annex C, steps c) and d) (a subscript on the wrong half of a ratio)
- ISO 11546-2:1995, Annex C, first paragraph (a normative reference list with a misspelt word)

### [ISO 11690](https://docs.jmrp.io/phonometry/reference/errata/iso-11690/) (2 entries)

- ISO 11690-3:1998, Table C.2 (a value read off the edge of its own diagram)
- ISO 11690-3:1998, Annex B (two workstations whose positions and results are interchanged)

### [ISO 11819](https://docs.jmrp.io/phonometry/reference/errata/iso-11819/) (2 entries)

- ISO 11819-1:1997, Annex E (speed spreads that do not fit the regression printed beside them)
- ISO 11819-1:1997, Annex D (a table numbered after the next annex)

### [ISO 11820](https://docs.jmrp.io/phonometry/reference/errata/iso-11820/) (1 entry)

- ISO 11820:1996, Equations (20) and (22) (a temperature ratio the wrong way up)

### [ISO 11957](https://docs.jmrp.io/phonometry/reference/errata/iso-11957/) (4 entries)

- ISO 11957:1996, 6.2 (a low-frequency clearance that relaxes the rule above it)
- ISO 11957:1996, 6.2 (a diffuser clearance that restates the wall clearance)
- ISO 11957:1996, 6.7 (a correction method named by a word that is not one)
- ISO 11957:1996, 7.2.1 (a signal-to-background rule with two words transposed)

### [ISO/TS 12913](https://docs.jmrp.io/phonometry/reference/errata/iso-12913/) (7 entries)

- ISO/TS 12913-3:2019, Annex A.3 (the perceived affective quality called part 3)
- ISO/TS 12913-3:2019, Formula (A.3) (a stray factor 1)
- ISO/TS 12913-3:2019, Formula (A.4) (the where-list of the tie counts)
- ISO/TS 12913-3:2019, Formula (B.2) ($x_I$ for $x_i$)
- ISO/TS 12913-2:2018, A.3 f), NOTE (exponent 3 for a cube root)
- ISO/TS 12913-2:2018, C.3.2.3 against Figure C.7 (three scales in the text, four in the figure)
- ISO/TS 12913-2:2018, Figures C.2 to C.4 ("extend" for "extent", "reponse" for "response")

### [ISO 12999](https://docs.jmrp.io/phonometry/reference/errata/iso-12999/) (3 entries)

- ISO 12999-1:2020, Table 4 (missing 500 Hz row)
- ISO 12999-2:2020, Clause 8 wording vs Tables 4 and 5
- ISO 12999-2:2020, Table 5 (octave-band data under a one-third-octave header)

### [ISO 13474](https://docs.jmrp.io/phonometry/reference/errata/iso-13474/) (3 entries)

- ISO 13474:2009, Annex A.2 (the level of each class credited to Equations (7) and (8))
- ISO 13474:2009, Annex A.2 (the shift of Equation (22) printed as 1.04 dB)
- ISO 13474:2009, Annex A.2, Figure A.3 (exceedance levels that are not the roots of Equation (25))

### [ISO 14257](https://docs.jmrp.io/phonometry/reference/errata/iso-14257/) (4 entries)

- ISO 14257:2001, Annex C (an example that corrects one of its two results)
- ISO 14257:2001, Equation (5) against Equation (8) (a rounded logarithm)
- ISO 14257:2001, Equation (4) against Table 1 (a second rounded constant)
- ISO 14257:2001, Annex C, Tables C.11 and C.12 (results Equation (8) does not give)

### [ISO 15186](https://docs.jmrp.io/phonometry/reference/errata/iso-15186/) (2 entries)

- ISO 15186-1, Clause 3.9, Formula (8) (sign of the 10 lg N term)
- ISO 15186-3:2002, Annex A, Table A.1 (steel-sandwich column irreproducible from its own inputs)

### [ISO/DIS 16032](https://docs.jmrp.io/phonometry/reference/errata/iso-16032/) (6 entries)

- ISO/DIS 16032:2023, Annex A, Table A.1 (the one-third-octave C-weighting at 25 Hz and from 1 600 Hz up)
- ISO/DIS 16032:2023, 7.6 (the background correction sent to Clause 8, the reverberation time)
- ISO/DIS 16032:2023, B.10 (the corner selection sent to Clause 6)
- ISO/DIS 16032:2023, 7.4.1 (no rule at a spread of exactly 6.0 dB or 9.0 dB)
- ISO/DIS 16032:2023, 4.8, Formula (5) (the S-weighted maximum level listed twice)
- ISO/DIS 16032:2023, 4.2 (the band definitions credited to "IEC 612604.3")

### [ISO 16283](https://docs.jmrp.io/phonometry/reference/errata/iso-16283/) (4 entries)

- ISO 16283-1:2014, Clause 6 (a source-room reverberation time)
- ISO 16283-1:2014, Clause 7.5.3 (a helix that ends "no more than 0,5 m from the ceiling")
- ISO 16283-2:2020, Clause 8.3 (a source room in an impact measurement)
- ISO 16283-2:2020, Clause 10.3 (a receiving room of exactly $25\ \text{m}^3$)

### [ISO 17208](https://docs.jmrp.io/phonometry/reference/errata/iso-17208/) (1 entry)

- ISO 17208-2:2019, Clause 5 uncertainty band coverage

### [ISO/TR 17534](https://docs.jmrp.io/phonometry/reference/errata/iso-17534/) (2 entries)

- ISO/TR 17534-3:2015, Table 20 (q credited to the wrong footnote of ISO 9613-2 Table 3)
- ISO/TR 17534-3:2015, Table 69 (the worked TRC form answers "yes" for a result below its lower limit)

### [ISO/PAS 20065](https://docs.jmrp.io/phonometry/reference/errata/iso-20065/) (1 entry)

- ISO/PAS 20065:2016, clause 5.3.4 (edge steepness of a distinct tone)

### [IEC 60118](https://docs.jmrp.io/phonometry/reference/errata/iec-60118/) (9 entries)

- IEC 60118-4:2014, 6.4 NOTE 2, and IEC 62489-1:2010, 5.4.8.2 NOTE 3 (the responses of the band-limiting filters exchanged)
- IEC 60118-4:2014, 6.4 (the filter order printed as "one-third-order")
- IEC 60118-4:2014, 6.6 and 8.2.1 (the meter cross-referenced to 5.1)
- IEC 60118-4:2014, Figure 2 a) (the outer radius keyed as 200 mm)
- IEC 60118-4:2014, Annex A.4 against 9.5 (+12 dB at 1.45 m for a counter)
- IEC 60118-4:2014, Figure E.2 a) (the vertical-field line drawn along the length)
- IEC 60118-4:2014, E.6 (the flux density of 1 A/m printed as 1.256 µT)
- IEC 60118-4:2014/A1:2017, 8.4 (cross-references to 10.2.7 left behind by the renumbering)
- IEC 60118-4:2014, 10.2.7, and IEC 60118-4:2014/A1:2017, 10.4.7 (a reference signal-to-noise ratio of exactly 47 dB)

### [IEC 60268](https://docs.jmrp.io/phonometry/reference/errata/iec-60268/) (15 entries)

- IEC 60268-1:1985, Appendix A, Figure A1 (last shunt capacitor printed as 41.47 nF)
- IEC 60268-1:1985, Appendix A, Table AII (lower-limit row slipped one column)
- IEC 60268-1:1985, Appendix A, Table AI (16 000 Hz tolerance printed as ±1.65)
- IEC 60268-3:2013, clause 14.12.9.2 f) (DIM denominator)
- IEC 60268-16:2011, Table M.1 (the beta row states the wrong redundancy term)
- IEC 60268-16:2011, Table M.1 (I_k tabulated a million times its neighbours)
- IEC 60268-16:2011, Table M.1 (step 3 I_am,k at 250 Hz)
- IEC 60268-7:2010, 8.7.3.3, Formula (3) ($U_{470}$ for the product at 460 Hz)
- IEC 60268-7:2010, 8.7.4.2 c), Formula (5) (a closing parenthesis with no opening one)
- IEC 60268-7:2010, 8.7.4.2 a) (the test signal sent to 8.7.3.1)
- IEC 60268-7:2010, Figure 3, NOTE (the head and torso simulator cited as IEC 60969)
- IEC 60268-7:2010, 8.6.3 to 8.6.5 (cross-references that miss their subclause)
- IEC 60268-7:2010, Table 1 (six clause numbers that name another subclause)
- IEC 60268-7:2010, 8.3.4.2 NOTE 1 (a crest factor credited to IEC 60268-1)
- IEC 60268-7:2010, 8.5.2 b) and 8.5.3 c) (two settings of the e.m.f. of 1 mW)

### [IEC 60534](https://docs.jmrp.io/phonometry/reference/errata/iec-60534/) (10 entries)

- IEC 60534-8-3:2010, Annex A (the piping geometry factor is printed rounded, and the annex did not use the rounded value)
- IEC 60534-8-3:2010, Table A.1 (an equivalent orifice diameter ten times too small, contradicted by the row below it)
- IEC 60534-8-3:2010, Table A.2 (two frequency factors whose exponent is one power of ten out)
- IEC 60534-8-4:2005, Equation (12) (the Strouhal number is printed one way in the clause and another in the annex)
- IEC 60534-8-4:2005, Table A.1 (a band transmission loss printed without its minus sign)
- IEC 60534-8-4:2005, 6.3.2 b) (a seat diameter formula whose constant is not in the unit its symbol is declared in)
- IEC 60534-8-4:2005, Equation (23b) (a stage inlet pressure computed from the next stage instead of the previous one)
- IEC 60534-8-4:2005, Equations (18a) and (18b) (two conditions that do not divide the domain between them)
- IEC 60534-8-4:2005, Equations (19a) and (19b) (a turbulent condition written against the wrong ratio, and two conditions that both claim the threshold and x_F = 1)
- IEC 60534-8-4:2005, Table A.1 (three printed intermediates its own equations do not reproduce)

### [IEC 61063](https://docs.jmrp.io/phonometry/reference/errata/iec-61063/) (1 entry)

- IEC 61063:1991, 8.3 ($L_{p\mathrm{A}I}$ for $L_{p\mathrm{A}i}$)

### [IEC 61094 and EN 61094](https://docs.jmrp.io/phonometry/reference/errata/iec-61094/) (9 entries)

- IEC 61094-5:2016, D.3 (a combined uncertainty its own components do not give)
- UNE-EN 61094-5:2017, Table D.1 and D.3 (six values dropped and the combined uncertainty misprinted in translation)
- IEC 61094-8:2012, 8.4 (an unresolved cross-reference)
- IEC 61094-8:2012, B.2.1 (the frequency range required of the transform over time)
- IEC 61094-8:2012, B.2.1 (the frequency increment said to set the time resolution)
- IEC 61094-8:2012, B.6.1, Formula (B.10) (the spectrum of a pulse of duration 2b called one of duration b)
- IEC 61094-2:2009, Tables B.1 and B.2 (a radius printed to four figures, a decimal point and a dropped digit)
- IEC 61094-3:2016, Formulas (8) and (9) (the factor −j of Formula (7) dropped)
- IEC 61094-3:2016, B.2 Step 1 (a coefficient of the saturation vapour pressure misprinted)

### [IEC 61183](https://docs.jmrp.io/phonometry/reference/errata/iec-61183/) (1 entry)

- IEC 61183:1994, note to A.1.8 (two equal-area angles that break the list's own symmetry)

### [IEC 61260 and EN 61260](https://docs.jmrp.io/phonometry/reference/errata/iec-61260/) (6 entries)

- IEC 61260-2:2016 / IEC 61260-3:2016, Annex A, Formula (A.2) (the coefficient of the frequency terms left unsquared)
- IEC 61260-3:2016, B.2.6 (an averaging period that ends 6 s to 7 s after the sweep passes 6.3 Hz)
- IEC 61260-2:2016, 7.2.4.3 and Formula (3), with IEC 61260-1:2014, 5.16 (the summation difference taken both ways round)
- EN 61260:1995, 3.2, NOTE 3 (the base-two octave ratio labelled base-ten)
- EN 61260:1995, 3.15 (the normalizing constant printed with a stray factor of ten)
- EN 61260:1995, 4.9 and 5.8.3, equation (19) (the summation difference taken both ways round)

### [IEC TS 61400](https://docs.jmrp.io/phonometry/reference/errata/iec-61400/) (9 entries)

- IEC TS 61400-11-2:2024, Table 7 (the 10 °C, 80 % row computed at −10 °C)
- IEC TS 61400-11-2:2024, 12.5.2.6 and 12.5.2.7 (ISO/TS 60025:2022 for ISO/TS 20065:2022)
- IEC TS 61400-11-2:2024, 13.6.2.2 against 13.6.3 (a 10 min period of exactly 30 valid blocks)
- IEC TS 61400-11-2:2024, Figure 1 ("Power specimen amplitude", "Initiate estimate")
- IEC TS 61400-11-2:2024, Table C.2 (the air attenuation of an 80 % atmosphere under a 70 % caption)
- IEC TS 61400-11-2:2024, C.4 (uncertainty cross-referenced to 9.2, which is data sampling)
- IEC TS 61400-11-2:2024, Table C.4 (the distance term added where Equation (C.1) subtracts it)
- IEC TS 61400-11-2:2024, G.3 (band ends of 3 200 Hz and 6 400 Hz, which are not band centres)
- IEC TS 61400-11-2:2024, K.4.9 (a sentence that stops at a comma)

### [IEC 61672](https://docs.jmrp.io/phonometry/reference/errata/iec-61672/) (1 entry)

- IEC 61672-1:2013, Table 3 (the class 1 lower limit at 6 300 Hz printed with a decimal point)

### [IEC 62489](https://docs.jmrp.io/phonometry/reference/errata/iec-62489/) (4 entries)

- IEC 62489-1:2010, Table B.1 (the counter loop's perimeter)
- IEC 62489-1:2010+A1:2014, 5.4.8.2 a) (the maximum output current cross-referenced to 5.4.5)
- IEC 62489-1:2010+A1:2014, 5.4.14.1 (the fall where the fields subtract printed as 0.72 dB)
- IEC 62489-1:2010+A1:2014, F.2.3 (the target response cross-referenced to a Figure 1)

### [IEC 62585](https://docs.jmrp.io/phonometry/reference/errata/iec-62585/) (3 entries)

- IEC 62585:2012, Table I.2 (a coverage factor its own degrees of freedom do not give)
- IEC 62585:2012, Table H.1 (the exponent of index 31)
- IEC 62585:2012, Formulas (E.4) to (E.6) (the two readings in the coupler exchanged)

### [EN 1793](https://docs.jmrp.io/phonometry/reference/errata/en-1793/) (6 entries)

- EN 1793-5:2016, Formula (1) against Formula (4) (a gain factor that multiplies)
- EN 1793-5:2016, Table B.2 (seven expanded uncertainties a hundredth below 1.96 times the printed $s_R$)
- EN 1793-5:2016, 5.5.7 against 5.8 (a low frequency limit read against the bands two ways)
- EN 1793-5:2016, Table 1 against Formula (7) (what $T_{W,BH}$ is the length of)
- EN 1793-5:2016, 5.5.5 ("microphones 1 to 3, microphones 4 to 6 and microphones 1 to 9")
- EN 1793-5:2016, Figure 15 Key (a distance from the loudspeaker named $d_M$, and a garbled item B)

### [ISO 12354 and EN 12354](https://docs.jmrp.io/phonometry/reference/errata/iso-12354/) (17 entries)

- EN 12354-1:2000 Formula (E.5) / ISO 12354-1:2017 E.3.4 (K24 clamp misprint)
- EN 12354-1:2000, Figure E.9 (E.7) (K24 stated in the figure-axis mass ratio)
- EN 12354-2:2000, Formula (3) vs Annex E.3 (standardized impact level)
- EN 12354-3:2000, Formula (5) (reduced form of the normalized level difference)
- EN 12354-3:2000, Formula (13) vs its own Annex F example (the "6" constant)
- EN 12354-3:2000, Annex F.1.3 (the 1 kHz and 2 kHz R' cells)
- EN 12354-5:2009, Table F.1 and clause F.4.2 (reference force printed as 1 pN)
- EN 12354-5:2009, Figure D.3 Key (three curves under one symbol)
- ISO 12354-1:2017 Table L.3 / ISO 12354-2:2017 Table G.3 (perimeter sums)
- ISO 12354-1:2017 Table L.3 / ISO 12354-2:2017 Table G.3 (external wall ηint)
- ISO 12354-1:2017, Table L.4 (second path block labelled 2d)
- ISO 12354-1:2017, Table L.1 (non-integer weighted ratings)
- ISO 12354-2:2017, Table G.1 (50 Hz to 80 Hz flanking columns)
- ISO 12354-2:2017, Table G.8 (junction Kij and m'i)
- ISO 12354-2:2017, Table G.6 (mislabelled row)
- ISO 12354-1:2017 Table L.10 / ISO 12354-2:2017 Table G.10 (element label)
- ISO 12354-1:2017, Table D.1 (1 600 Hz covered by two rows)

### [EN 15461](https://docs.jmrp.io/phonometry/reference/errata/en-15461/) (1 entry)

- EN 15461:2008+A1:2010, 6.7 against Figure 2 (twenty-eight hammer positions in the text, twenty-nine in the drawing)

### [EN 15610](https://docs.jmrp.io/phonometry/reference/errata/en-15610/) (2 entries)

- EN 15610:2009, Annex B, B.9.2 (a spike-removal loop that asks for no change of sign and never ends on a bend)
- EN 15610:2009, Annex B, B.9.2 (Method B filters run forward and back, outside every class of EN 61260)

### [EN 15657](https://docs.jmrp.io/phonometry/reference/errata/en-15657/) (1 entry)

- UNE-EN 15657:2018, Clause 7.1, Formula (14) (reference mass dimensionally inconsistent with the quantity it normalises)

### [EN 16272](https://docs.jmrp.io/phonometry/reference/errata/en-16272/) (1 entry)

- EN 16272-3-1:2012, Clause 6 (a railway rating weighted by "the normalised traffic noise spectrum")

### [EN 61043](https://docs.jmrp.io/phonometry/reference/errata/en-61043/) (1 entry)

- UNE-EN 61043:1999, clause 6.1 (class 2 frequency range dropped in translation)

### [DIN 4150](https://docs.jmrp.io/phonometry/reference/errata/din-4150/) (16 entries)

- DIN 4150-2:1999-06, Annex A, Formula (A.1b) (a clock maximum r.m.s. equated to a mean of squares)
- E DIN 4150-2:2023-08, Annex B, Example 9 (the night assessed over 920 clock intervals instead of 960)
- E DIN 4150-2:2023-08, Annex B, Figure B.2 b) (clock maxima printed on the figure that do not give the 0.39 the example uses)
- E DIN 4150-2:2023-08, Annex A, Figure A.1 (a decision drawn with its answer the wrong way round)
- E DIN 4150-2:2023-08, Annex B, B.9.3.1 (an extension assessed by the clause for a new line)
- E DIN 4150-2:2023-08, 6.5.3.6 (requirements met when one condition holds, and an example that needs them all)
- E DIN 4150-2:2023-08, 6.5.3.6 a) and b) (a maximum at the upper value itself, which neither dash takes)
- E DIN 4150-2:2023-08, Annex B, B.8.3.4 (a result that its own four-decimal inputs do not give)
- E DIN 4150-2:2023-08, Annex B, B.4.3.3 (the clock maximum r.m.s. attributed to Formula (2))
- E DIN 4150-2:2023-08, Annex B, B.3.2 (a note cited under the clause it was moved out of)
- E DIN 4150-2:2023-08, 6.3 (a rare event met below the upper value in the prose and at it in the flowchart)
- DIN 4150-1:2001-06, Formulae (5) and (6) (a distance whose unit is printed as millimetres)
- DIN 4150-1:2001-06, Clause 5.2.3 (a low working frequency written as a high one)
- DIN 4150-1:2001-06, Annex A, Figure A.2 (a legend that swaps two line styles)
- DIN 4150-1:2001-06, Annex A, A.5.1 (an eccentric moment with the unit of a force)
- DIN 4150-1:2001-06, Annex A, Figure A.18 (a point labelled all groups at the count of one hall)

### [DIN 45669](https://docs.jmrp.io/phonometry/reference/errata/din-45669/) (2 entries)

- DIN 45669-1:2010-09, Table 9 (a peak-velocity row that contradicts Formula (5), and the $KB_\mathrm{F}$ row beside it)
- DIN 45669-2:2005-06, Clause 5.1.4 (a coupling clause cited by the wrong number)

### [DIN 45672](https://docs.jmrp.io/phonometry/reference/errata/din-45672/) (9 entries)

- DIN 45672-1:2009-12, Clause 4.5.1, Formulae (1) and (5) (the compression-wave speed of a thin rod, and a radicand short of a factor 2)
- DIN 45672-2:1995-07, Clause 4 (the start-up of the running r.m.s., quoted in mean square)
- E DIN 45672-3:2023-02, Annex C, C.3 (two assessment severities that weight by the factor once where Formula (11) squares it)
- E DIN 45672-3:2023-02, Annex C, Table C.1 (a sum level formed without the weighting Clause 7.1 prescribes)
- E DIN 45672-3:2023-02, Annex C, C.2 and Table C.1 (a floor transfer that comes from no table of Annex A, and a figure cited by the wrong number)
- E DIN 45672-3:2023-02, Annex A, Table A.6 (a lower deviation printed above the mean it deviates from)
- E DIN 45672-3:2023-02, Figures 5, 6 and 7 (legends that name the wrong table and the wrong quantity)
- E DIN 45672-3:2023-02, 5.4.4 (an annex called normative where it is printed informative)
- E DIN 45672-3:2023-02, Formula (11) (the assessment sum printed without the rule that zeroes a quiet category)

### [DIN 45681](https://docs.jmrp.io/phonometry/reference/errata/din-45681/) (2 entries)

- DIN 45681:2005-03, Anhang I, Tabelle I.6, row "6 FG"
- DIN 45681:2005-03, Anhang I, Tabellen I.2 and I.10 (wrong spectrum index in a column header)

### [ANSI S1.4](https://docs.jmrp.io/phonometry/reference/errata/ansi-s1-4/) (1 entry)

- ANSI S1.4-1983, Table V, 20 Hz type 2 cell (a plus sign that lost its bar)

### [ANSI S3.5](https://docs.jmrp.io/phonometry/reference/errata/ansi-s3-5/) (2 entries)

- ANSI S3.5-1997, Annex C worked examples (official WG S3-79 errata)
- ANSI S3.5-1997, captions of Tables 1 to 4 (official WG S3-79 erratum)

### [ECMA-418](https://docs.jmrp.io/phonometry/reference/errata/ecma-418/) (11 entries)

- ECMA-418-1:2024 (3rd edition), clause 4.1.1 NOTE 2 (upper limit of the discrete-tone range)
- ECMA-418-1:2024 (3rd edition), Formula (21) (repeated constant term)
- ECMA-418-1:2024 (3rd edition), clause 11.3 (unresolved field references)
- ECMA-418-1:2024 (3rd edition), clause 12.4 (the upper band edge sent to Formula (21))
- ECMA-418-1:2024 (3rd edition), Formula (23) (the condition of Formula (24) printed beside it)
- ECMA-418-1:2024 (3rd edition), clause 12.5 (the truncation of the lower band cross-referenced to 12.4)
- ECMA-418-2:2025 (4th edition), clause 5.1.5.2 (last block index)
- ECMA-418-2:2025 (4th edition), clause 9.1.4, Formula (127) (HSA kernel phase)
- ECMA-418-2:2025 (4th edition), clause 9.1.5, Formula (144) (bin offset)
- ECMA-418-2:2025 (4th edition), clause 9.1.7 (units of the fine-tuning constants)
- ECMA-418-2:2025 (4th edition), clause 9 introduction (broken cross-reference)

### [ITU-R BS.468](https://docs.jmrp.io/phonometry/reference/errata/itu-r-bs-468/) (1 entry)

- ITU-R BS.468-4, Table 2, 5 ms upper limit (the dB cell should read −6.7)

### [VDI 2081](https://docs.jmrp.io/phonometry/reference/errata/vdi-2081/) (6 entries)

- VDI 2081 Blatt 1:2001, Section 6.7.3 (the symbol list of Equation (36) sends A back to Equation (36))
- VDI 2081 Blatt 1:2001, Section 6.7.3 (the English column calls a hemispherical propagation spherical)
- VDI 2081 Blatt 1:2001-07, Section 6.4 (the English column says the opposite of the German)
- VDI 2081 Blatt 2:2005-05, Table 1, element 2 (the hydraulic diameter it prints is not the one it computes with)
- VDI 2081 Blatt 2:2005-05, Table 1, element 14 (the element's own row contradicts the one above it)
- VDI 2081 Blatt 2:2005-05, Table 1, element 2 (a cross-reference to the wrong clause)

## Guidance, regulations, books and papers

One page per document, named after its authors or its issuer.

### [Ainslie (2010)](https://docs.jmrp.io/phonometry/reference/errata/ainslie/) (2 entries)

- Ainslie (2010), Equation (4.6) vs its own folio 177, and the exponent of Equation (4.13)
- Ainslie, Principles of Sonar Performance Modelling (2010), Eq. (9.57)

### [Allard & Atalla (2009)](https://docs.jmrp.io/phonometry/reference/errata/allard-atalla/) (8 entries)

- Allard & Atalla, Propagation of Sound in Porous Media 2e (2009), Eq. (6.85)
- Allard & Atalla 2e (2009), Eq. (11.48) and Table 11.1 (poroelastic layer)
- Allard & Atalla 2e (2009), Sect. 6.6.3 (thickness of the second sample)
- Allard & Atalla 2e (2009), Sect. 6.5.4 (the frame-borne velocity ratio)
- Allard & Atalla 2e (2009), Table 11.7 (the figure its caption names)
- Allard & Atalla 2e (2009), Table 11.8 (the thickness of the glass wool)
- Allard & Atalla 2e (2009), Table 11.9 (the thickness of the plate)
- Allard & Atalla 2e (2009), Table 13.2 (the Young's modulus of the rockwool)

### [ASHRAE (2019)](https://docs.jmrp.io/phonometry/reference/errata/ashrae/) (1 entry)

- ASHRAE (2019) HVAC Applications Handbook, Chapter 49, folio 49.31 (the sentence that introduces the break-in tables swaps two of them)

### [Attenborough & Van Renterghem (2021)](https://docs.jmrp.io/phonometry/reference/errata/attenborough-van-renterghem/) (3 entries)

- Attenborough & Van Renterghem, Predicting Outdoor Sound 2e (2021), Eq. (4.35)
- Attenborough & Van Renterghem, Predicting Outdoor Sound 2e (2021), Table 5.1
- Attenborough & Van Renterghem, Predicting Outdoor Sound 2e (2021), Eq. (5.13)

### [Barham, Barrera-Figueroa & Avison (2014)](https://docs.jmrp.io/phonometry/reference/errata/barham-barrera-figueroa-avison/) (1 entry)

- Barham, Barrera-Figueroa & Avison (2014), Metrologia 51, 129, Formulas (1), (2) and (4) (a model that does not give its own Table 2)

### [Bies, Hansen & Howard (2017)](https://docs.jmrp.io/phonometry/reference/errata/bies-hansen-howard/) (4 entries)

- Bies, Hansen & Howard, Engineering Noise Control 5e (2017), Eq. (8.141)
- Bies 5e (2017), Table C.1 (three speeds that do not follow from the two columns they are said to be calculated from)
- Bies 5e (2017), Table C.2 (four molar masses that do not belong to the gas in the row)
- Bies 5e (2017), Table C.2 (two ratios of specific heats that no gas can have)

### [Cox & D'Antonio (2017)](https://docs.jmrp.io/phonometry/reference/errata/cox-dantonio/) (3 entries)

- Cox & D'Antonio, Acoustic Absorbers and Diffusers 3e (2017), Appendix D (two rows the table cannot tell apart)
- Cox & D'Antonio, Acoustic Absorbers and Diffusers 3e (2017), Appendix B (a width in centimetres that its own geometry makes metres)
- Cox & D'Antonio, Acoustic Absorbers and Diffusers 3e (2017), Table 6.7 (six porosities printed in per cent in a column of fractions)

### [Directive (EU) 2015/996](https://docs.jmrp.io/phonometry/reference/errata/directive-eu-2015-996/) (6 entries)

- Commission Directive (EU) 2015/996, Annex II 2.2.1 (octave-band range of the road source)
- Directive (EU) 2015/996, Annex II 2.3.2 (roughness conversion in km/h)
- Directive (EU) 2015/996, Appendix G, Table G-1, second table (wrong symbol)
- Directive (EU) 2015/996, Appendix G, Table G-5, 6 350 Hz row (50 dB notch)
- Directive (EU) 2015/996, Appendix G, band and wavelength labels
- Directive (EU) 2015/996, Annex II 2.3.2, curve squeal (unassigned endpoints)

### [ECAC Doc 29](https://docs.jmrp.io/phonometry/reference/errata/ecac-doc-29/) (5 entries)

- ECAC Doc 29, 5th ed., Volume 2, Appendix B, Eq. (B-41) (descent deceleration)
- ECAC Doc 29, 5th ed., Volume 2, Appendix B, Eq. (B-18) (runway gradient)
- ECAC Doc 29, 5th ed., Volume 2, Appendix B, Eq. (B-21) (mid-step airspeed)
- ECAC Doc 29, 5th ed., Volume 2, Appendix D, Table D-6c (the last row is the last row of Table D-6b)
- ECAC Doc 29, 5th ed., Volume 2, Appendix D, text under Table D-2 (Tables D-3b and D-3c paired with the wrong methods)

### [Harris (1995)](https://docs.jmrp.io/phonometry/reference/errata/harris/) (2 entries)

- Harris 3e (1995), Tables 32.1 to 32.8 (nineteen double-unit pairs whose two halves are not each other)
- Harris 3e (1995), Table 30.2 (five pile weights whose two halves are not each other)

### [ICAO Annex 16](https://docs.jmrp.io/phonometry/reference/errata/icao-annex-16/) (1 entry)

- ICAO Annex 16, Volume I, 8th edition (2017), Appendix 2, 4.4.2 (the minus sign of the bandsharing adjustment missing)

### [Jarvis (1996)](https://docs.jmrp.io/phonometry/reference/errata/jarvis/) (1 entry)

- Jarvis (1996), NPL Report CIRA(EXT) 010, Appendix B (the imaginary unit of the first microphone's mass missing from the published scan)

### [Jiménez et al. (2017)](https://docs.jmrp.io/phonometry/reference/errata/jimenez/) (2 entries)

- Jiménez, Groby, Pagneux & Romero-García (2017), Appl. Sci. 7(6), 618, Eqs. (7)-(8)
- Jiménez et al. (2017), Appl. Sci. 7(6), 618 / Sci. Rep. 7, 5389, slit-radiation term

### [Long (2014)](https://docs.jmrp.io/phonometry/reference/errata/long/) (4 entries)

- Long, Architectural Acoustics 2e (2014), Eq. (18.24) (sign of the microphone directivity)
- Long, Architectural Acoustics 2e (2014), Eq. (17.53) (constant of the communication bound)
- Long, Architectural Acoustics 2e (2014), Table 14.7 (round elbow rows)
- Long, Architectural Acoustics 2e (2014), Eq. 13.28 (units of U_G)

### [Maa (1998)](https://docs.jmrp.io/phonometry/reference/errata/maa/) (1 entry)

- Maa (1998), "Potential of microperforated panel absorber", JASA 104(5), Eq. (5b)

### [Mechel (2008)](https://docs.jmrp.io/phonometry/reference/errata/mechel/) (1 entry)

- Mechel (2008), Table 3 (a wall impedance its own Equation (11) does not give)

### [Medwin & Clay (1998)](https://docs.jmrp.io/phonometry/reference/errata/medwin-clay/) (2 entries)

- Medwin & Clay, Fundamentals of Acoustical Oceanography (1998), Eq. (3.4.30) (boric-acid coefficient)
- Medwin & Clay (1998), Eq. (3.4.30) (sound speed printed as q)

### [NMFS (2024)](https://docs.jmrp.io/phonometry/reference/errata/nmfs/) (1 entry)

- NMFS (2024) Updated Technical Guidance v3.0, Table 5 / Table ES2 (otariid C)

### [NORAH2 rotorcraft guidance](https://docs.jmrp.io/phonometry/reference/errata/norah2/) (8 entries)

- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), Eq. (27)
- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), Eq. (21)
- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), §A.3.1 triangulation
- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), Eq. (46)
- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), §A.4.5 cross-references
- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), §A.3.5 Approach 3 (full-rpm idle base)
- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), §A.3.5 taxi assignment
- NORAH2 rotorcraft guidance SC01.D1.5d (EASA.2020.FC.06), Table 3 offsets vs the shipped corrections

### [Norton & Karczub (2003)](https://docs.jmrp.io/phonometry/reference/errata/norton-karczub/) (5 entries)

- Norton & Karczub, Fundamentals of Noise and Vibration Analysis for Engineers 2e (2003), Eq. (6.56)
- Norton & Karczub 2e (2003), problem 6.13 answer (eta_21 column)
- Norton & Karczub 2e (2003), problem 6.10 (platform area)
- Norton & Karczub 2e (2003), problem 3.14 (structural loss factor)
- Norton & Karczub 2e (2003), Appendix 4 (the Young's modulus of cork, three powers of ten too large)

### [Osses, García & Kohlrausch (2016)](https://docs.jmrp.io/phonometry/reference/errata/osses-garcia-kohlrausch/) (1 entry)

- Osses, García & Kohlrausch (2016), fluctuation-strength model, Eq. (3)

### [RANDI 3.1 Physics Description](https://docs.jmrp.io/phonometry/reference/errata/randi/) (1 entry)

- RANDI 3.1 Physics Description (NRL, Breeding et al.), Table 2

### [Real Decreto 1367/2007](https://docs.jmrp.io/phonometry/reference/errata/real-decreto-1367-2007/) (2 entries)

- Real Decreto 1367/2007, Annex IV A.3.3 (Kf and Ki threshold tables)
- Real Decreto 1367/2007, Article 30.1 and 30.2 (the metrology Order credited to the Ministerio de Fomento)

### [Rossing (2014)](https://docs.jmrp.io/phonometry/reference/errata/rossing/) (6 entries)

- Rossing (2014), Table 15.5 (a relative scaling factor that its own row does not give)
- Rossing (2014), Table 11.4 ("Open-plane" for an open-plan office)
- Rossing (2014), Table 8.3 (the 1-pentanol line printed twice)
- Rossing (2014), Table 8.1 (a year its own reference list contradicts)
- Rossing (2014), Table 8.4 ("at atmospheric pressure" for six gases above their boiling point)
- Rossing (2014), Table 6.5 ("Flourite" for fluorite)

### [Southall et al. (2019)](https://docs.jmrp.io/phonometry/reference/errata/southall/) (1 entry)

- Southall et al. (2019), Aquatic Mammals 45(2), Table 7 (impulsive peak SPL)

### [Ver & Beranek (2006)](https://docs.jmrp.io/phonometry/reference/errata/ver-beranek/) (4 entries)

- Ver & Beranek 2e (2006), TABLE 14.1 (three moduli whose e-notation is corrupted in the printing)
- Ver & Beranek 2e (2006), TABLE 14.1 (a transition modulus printed below the smallest modulus of its own row)
- Ver & Beranek 2e (2006), TABLE 8.5 (mass per unit area of the finest mesh, ten times too large in pounds)
- Ver & Beranek 2e (2006), TABLE 8.6 (the two surface-density columns disagree by one wrong factor on every row)

### [Vigran (2008)](https://docs.jmrp.io/phonometry/reference/errata/vigran/) (3 entries)

- Vigran, Building Acoustics (2008), Figure 8.37 caption (carpet stiffness exponent)
- Vigran, Building Acoustics (2008), Eq. (9.18) (receiving-side coefficient)
- Vigran (2008), Table 3.1 (a Poisson ratio whose second endpoint has lost its decimal point)

## Properties that are not errata

Properties of the sources that look like misprints and are not, recorded so that nobody corrects the library to match them.

### [Source properties that are not errata](https://docs.jmrp.io/phonometry/reference/errata/not-errata/) (1 entry)

- Related source properties that are not errata