# Errata in IEC TS 61400

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iec-61400/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iec-61400/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in IEC TS 61400: 9 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 9 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on IEC TS 61400-11-2:2024, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## IEC TS 61400-11-2:2024, Table 7 (the 10 °C, 80 % row computed at −10 °C)

- **Location:** 12.5.2.4, Table 7 "Upper tone search frequencies based on a
  range of distance and meteorological conditions" (printed folio 45), the row
  "10 | 80".
- **The print:** 10, 5, 2,5 and 2 kHz at 100 m, 300 m, 600 m and 1 000 m.
- **The problem:** 12.5.2.4 puts the top of the tone search at the lowest
  one-third-octave band that ISO 9613-1 attenuates by 20 dB or more over the
  distance to the nearest turbine. At 10 °C and 80 % relative humidity that
  band is 10, 6.3, 5 and 4 kHz. The printed cells are what the same rule gives
  at −10 °C and 80 %, cell for cell. The other four rows reproduce at their own
  atmospheres (the "3,2" of the −10 °C, 100 % row is the 3.15 kHz band), so
  either the temperature of the row has lost its minus sign or its cells were
  computed at the wrong temperature. At the 10 °C and 80 % the row prints, it
  reads **10, 6.3, 5 and 4 kHz**.
- **Evidence:** the rule of 12.5.2.4 evaluated with ISO 9613-1 at the exact
  mid-band frequencies and 101.325 kPa for the twenty cells of the table.
  Table 7 read on PDF page 47 (printed p. 45) of IEC TS 61400-11-2:2024
  (Edition 1.0, 2024-03).
- **Library behaviour:** `upper_tone_search_frequency` applies the rule of
  12.5.2.4 and never reads Table 7, so no change was required. The conformance
  rows check the four rows that hold and the printed fourth row at −10 °C
  (`test_table_7_fourth_row_is_minus_10_degrees` in
  [`tests/environment/assessment/test_wind_turbine_receptor.py`](https://github.com/jmrplens/phonometry/blob/main/tests/environment/assessment/test_wind_turbine_receptor.py)).
- **Status:** unreported.

## IEC TS 61400-11-2:2024, 12.5.2.6 and 12.5.2.7 (ISO/TS 60025:2022 for ISO/TS 20065:2022)

- **Location:** 12.5.2.6 "Frequency grouping" (printed folio 46) and 12.5.2.7
  "Determination of mean audibility for each 1 min period" (printed folio 47).
- **The print:** 12.5.2.6 first cites "ISO method (ISO/TS 20065:2022), 5.3.8,
  Step 1 and Step 2", and then "ISO method (ISO/TS 60025:2022), 5.3.8,
  Step 3", "ISO method (ISO/TS 60025:2022), Figure D.4" and "ISO method
  (ISO/TS 60025:2022), 5.3.8, Step 1 and Step, in turn"; 12.5.2.7 cites "ISO
  method (ISO/TS 60025:2022), 5.3.9".
- **The problem:** 12.1 defines the "ISO method" as ISO/TS 20065, its NOTE 1
  cites ISO/TS 20065:2022, and the first sentence of 12.5.2.6 cites it
  correctly; there is no ISO/TS 60025. The
  four later citations read **ISO/TS 20065:2022**, and "Step 1 and Step" reads
  "Step 1 and Step 2", the two steps the first sentence names.
- **Evidence:** a comparison of the citations with each other and with 12.1.
  Read on PDF page 44 (printed p. 42), PDF page 48 (printed p. 46) and PDF
  page 49 (printed p. 47) of IEC TS 61400-11-2:2024 (Edition 1.0, 2024-03).
- **Library behaviour:** none needed. The frequency grouping of 12.5.2.6 and
  the 1 min mean of 12.5.2.7 are not implemented; the tonal audibility the
  library computes is that of ISO/PAS 20065:2016
  ([`_tone_audibility.py`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/psychoacoustics/quality/_tone_audibility.py)).
- **Status:** unreported.

## IEC TS 61400-11-2:2024, 13.6.2.2 against 13.6.3 (a 10 min period of exactly 30 valid blocks)

- **Location:** 13.6.2.2 "Valid data" (printed folio 51) and 13.6.3 "Signal
  analysis – 10 min results" (printed folio 54).
- **The print:** 13.6.2.2: the 90th percentile "is only calculated over the
  distribution of valid 10 s blocks, and only if the 10 min period contains at
  least 50 % valid blocks". 13.6.3: "where the n number is greater than 50 %
  (30 valid 10 s blocks), calculate the 90th percentile of the valid
  modulation depths" and "where the n number is less than 50 % (30 valid 10 s
  blocks), a modulation depth value of 0 is assigned to that 10 min period".
- **The problem:** a period of sixty blocks with exactly 30 valid is rated by
  13.6.2.2 ("at least 50 %") and falls under neither bullet of 13.6.3, whose
  "greater than" and "less than" both leave it out. The AMWG Final Report the
  clause implements (13.2) says "at least 50 % (i.e. 30) valid samples"
  (4.4.4), and the working group's reference code rates a period of 30. The
  bullets of 13.6.3 read **"at least 50 %"** and **"fewer than 50 %"**.
- **Evidence:** a comparison of the two subclauses and of the AMWG report.
  Read on PDF page 53 (printed p. 51) and PDF page 56 (printed p. 54) of
  IEC TS 61400-11-2:2024 (Edition 1.0, 2024-03), and 4.4.4 on PDF page 23
  (printed p. 20) of the IOA AMWG Final Report, Version 1 (9 August 2016).
- **Library behaviour:** `amplitude_modulation_period` rates a period of 30
  valid blocks, as 13.6.2.2 and the AMWG report do
  (`AM_MIN_VALID_BLOCKS`); the conformance rows pin the periods of 30 and
  29 valid blocks
  (`test_periods_agree_with_the_ioa_code_and_the_ts` in
  [`tests/environment/assessment/test_wind_turbine_modulation.py`](https://github.com/jmrplens/phonometry/blob/main/tests/environment/assessment/test_wind_turbine_modulation.py)).
- **Status:** unreported.

## IEC TS 61400-11-2:2024, Figure 1 ("Power specimen amplitude", "Initiate estimate")

- **Location:** 13.6.2.3, Figure 1 "Power spectrum for a 10 s block" (printed
  folio 54).
- **The print:** the vertical axis is labelled "Power specimen amplitude, $S$"
  and the legend reads "Initiate estimate of $f_1$ and $f_2$".
- **The problem:** the axis is the power spectrum of Equation (12), which the
  caption and 13.6.2.3 c) name; "specimen" reads **spectrum**. The dashed lines
  are the initial estimates of the harmonics, as the NOTE under the figure and
  the annotations inside it ("Initial $f_1$ estimate = 1,4 Hz") say;
  "Initiate" reads **Initial**.
- **Evidence:** Figure 1 and its NOTE on PDF page 56 (printed p. 54) of
  IEC TS 61400-11-2:2024 (Edition 1.0, 2024-03).
- **Library behaviour:** none needed; `ModulationBlock.plot()` labels the axis
  "Power spectrum $S_{xx}$" and the lines "Estimated harmonics".
- **Status:** unreported.

## IEC TS 61400-11-2:2024, Table C.2 (the air attenuation of an 80 % atmosphere under a 70 % caption)

- **Location:** Annex C (informative), C.2, Table C.2 "Equation coefficients
  for a rural setting at 70 % humidity and 10 °C" (printed folio 64), the row
  "α [dB/km]", and the sentence under the table.
- **The print:** 0,0, 0,0, 0,0, 0,0, 0,02, 0,03, 0,05, 0,07, 0,11, 0,17,
  0,26, 0,41, 0,59 and 0,80 dB/km from 10 Hz to 200 Hz, and "The air
  absorption coefficient is calculated according to ISO 9613-1."
- **The problem:** ISO 9613-1 at the caption's 10 °C and 70 % relative
  humidity, at 101.325 kPa and the nominal band centres, gives to two decimals
  0.01, 0.01, 0.02 and 0.02 dB/km more than the table at 50 Hz, 63 Hz, 80 Hz
  and 100 Hz (0.08, 0.12, 0.19 and 0.28), and 0.01 dB/km where the table
  prints 0.0 at 12.5 Hz to 20 Hz; from 125 Hz to 200 Hz it gives the printed
  cells. The cells from 10 Hz to 100 Hz are those of the Danish statutory order
  on wind turbine noise, BEK nr. 135 of 7 February 2019, Table 1.4, which is
  set for **80 %** relative humidity and 10 °C, uses the Nord2000 attenuation
  rates and ignores air absorption below 25 Hz, as Plovsing (DELTA, 2011),
  Table 5, recommends; at 80 % ISO 9613-1 gives 0.07, 0.11, 0.17 and 0.25
  dB/km from 50 Hz to 100 Hz, within 0.01 dB/km of them. The row joins two
  atmospheres at 100 Hz, and a reader who recomputes it at the caption's
  cannot reproduce its lower half. The difference is at most 0.02 dB/km, a few
  hundredths of a decibel of Equation (C.1) at the distances Annex C is used
  for.
- **Evidence:** ISO 9613-1 evaluated at both humidities for the fourteen
  bands. Table C.2 read on PDF page 66 (printed p. 64) of IEC TS
  61400-11-2:2024 (Edition 1.0, 2024-03); Table 1.4 on PDF pages 13 and 14
  (printed pp. 12 and 13) of BEK nr 135 af 07/02/2019; Table 5 on PDF page 25
  (printed p. 25) of B. Plovsing, *Beregningsmetode for lavfrekvent støj fra
  vindmøller*, Miljøstyrelsen arbejdsrapport nr. 2, 2011.
- **Library behaviour:** `LOW_FREQUENCY_AIR_ATTENUATION_DB_PER_KM` holds the
  row as printed and is the default of `wind_turbine_low_frequency_level`,
  which reproduces the TS and the Danish order; a caller who wants ISO 9613-1
  at another atmosphere passes `air_attenuation_db_per_km`. The conformance
  rows check the row against both atmospheres
  (`test_table_c2_air_attenuation_to_100_hz_is_the_danish_order_at_80_percent`
  in
  [`tests/environment/assessment/test_wind_turbine_receptor.py`](https://github.com/jmrplens/phonometry/blob/main/tests/environment/assessment/test_wind_turbine_receptor.py)).
- **Status:** unreported.

## IEC TS 61400-11-2:2024, C.4 (uncertainty cross-referenced to 9.2, which is data sampling)

- **Location:** Annex C (informative), C.4 "Uncertainty" (printed folio 65).
- **The print:** "The principles from 9.2 on uncertainty can be applied to
  each 1/3-octave band individually."
- **The problem:** 9.2 is "Data sampling" of the non-acoustic measurements
  and says nothing about uncertainty. The principles are those of **10.3**
  "Uncertainty", to which 12.5.4 and 13.6.5 refer for the same purpose.
- **Evidence:** a comparison of the cross-reference with the table of contents
  and with 12.5.4 and 13.6.5. Read on PDF page 67 (printed p. 65), PDF page
  49 (printed p. 47) and PDF page 57 (printed p. 55) of IEC TS
  61400-11-2:2024 (Edition 1.0, 2024-03).
- **Library behaviour:** none needed; `wind_turbine_low_frequency_level`
  computes no uncertainty.
- **Status:** unreported.

## IEC TS 61400-11-2:2024, Table C.4 (the distance term added where Equation (C.1) subtracts it)

- **Location:** Annex C (informative), C.5, Table C.4 "Low frequency
  measurements reporting table" (printed folio 66), the third row.
- **The print:** the row is labelled "+ 10log ($l^2$ +$h^2$)", between the
  A-weighting row and the "− 11 dB" row.
- **The problem:** Equation (C.1) subtracts the term,
  $L_{p,\mathrm{LF}} = L_{W,\mathrm{LF}} - 10\lg(l^2 + h^2) - 11\ \mathrm{dB} +
  \Delta L_{\mathrm{g},\mathrm{LF}} - \Delta L_\mathrm{a} - \Delta L_\sigma$, and every other
  row of the table carries the sign with which it enters the equation. Filled
  in as labelled, the table adds twice the distance term to the level. The row
  reads **"− 10log ($l^2$ + $h^2$)"**.
- **Evidence:** Equation (C.1) on PDF page 65 (printed p. 63) and Table C.4 on
  PDF page 68 (printed p. 66) of IEC TS 61400-11-2:2024 (Edition 1.0,
  2024-03).
- **Library behaviour:** `wind_turbine_low_frequency_level` evaluates Equation
  (C.1) and reports the term it subtracts as `distance_terms_db`; the
  conformance row on Equation (C.1) checks the sign
  (`test_equation_c1_band_by_band` in
  [`tests/environment/assessment/test_wind_turbine_receptor.py`](https://github.com/jmrplens/phonometry/blob/main/tests/environment/assessment/test_wind_turbine_receptor.py)).
- **Status:** unreported.

## IEC TS 61400-11-2:2024, G.3 (band ends of 3 200 Hz and 6 400 Hz, which are not band centres)

- **Location:** Annex G (informative), G.3 "Higher frequency bands" (printed
  folio 73).
- **The print:** "These bands are suggested to include the seven 1/3-octave
  bands with centres of: Band 4: 400 Hz to 1 600 Hz; Band 5: 800 Hz to
  3 200 Hz; Band 6: 1 600 Hz to 6 400 Hz".
- **The problem:** 3 200 Hz and 6 400 Hz are not one-third-octave centre
  frequencies. Seven bands span two octaves, and the nominal centre two
  octaves above 800 Hz is 3 150 Hz, above 1 600 Hz it is 6 300 Hz; band 4
  ends right only because 1 600 Hz is both four times 400 Hz and a nominal
  centre. The ends read **3 150 Hz** and **6 300 Hz**.
- **Evidence:** the seven nominal one-third-octave centres counted from each
  lower end. Read on PDF page 75 (printed p. 73) of IEC TS 61400-11-2:2024
  (Edition 1.0, 2024-03).
- **Library behaviour:** `AM_FREQUENCY_BANDS_HZ` holds bands 5 and 6 with the
  nominal 3 150 Hz and 6 300 Hz bands as their seventh.
- **Status:** unreported.

## IEC TS 61400-11-2:2024, K.4.9 (a sentence that stops at a comma)

- **Location:** Annex K (informative), K.4.9 "Roughness length" (printed
  folio 85).
- **The print:** "Table K.3 is provided below as a reminder. Since this is a
  crude estimate, valid only for cloudy conditions and long-term average,",
  followed by blank lines and the next paragraph, "K.4.3 gives some guidance
  on how to determine an apparent roughness length ...".
- **The problem:** the sentence has a subordinate clause and no main clause;
  what the crude estimate implies is lost. The next paragraph suggests it was
  to send the reader to K.4.3 for a roughness length derived from the site.
- **Evidence:** K.4.9 on PDF page 87 (printed p. 85) of IEC TS
  61400-11-2:2024 (Edition 1.0, 2024-03).
- **Library behaviour:** none needed; `ROUGHNESS_LENGTHS_M` holds Table K.3
  and its docstring carries the TS's warning that the values are a crude
  estimate.
- **Status:** unreported.
