# Errata in DIN 4150

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/din-4150/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/din-4150/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in DIN 4150: 16 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 16 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on DIN 4150-2:1999-06, E DIN 4150-2:2023-08 and DIN 4150-1:2001-06, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## DIN 4150-2:1999-06, Annex A, Formula (A.1b) (a clock maximum r.m.s. equated to a mean of squares)

- **Location:** Annex A, Formulae (A.1a) and (A.1b) on printed page 11 (PDF
  page 11 of the copy read here, which prints its folios without an offset).
- **The print:** Formula (A.1a) reads $KB_\mathrm{FTm,j} = \sqrt{\frac{1}{M_\mathrm{j}}
  \sum_{\mathrm{i}=1}^{M_\mathrm{j}} KB^2_\mathrm{FTi,j}}$ and, "oder", Formula (A.1b) reads
  $KB_\mathrm{FTm,j} = \frac{1}{Z\mathrm{j}} \sum_{\mathrm{i}=1}^{Z\mathrm{j}} KB^2_\mathrm{FTi,j}$, for the case
  that only $Z\mathrm{j}$ occupied clock intervals of class $\mathrm{j}$ were measured.
- **The problem:** the second formula has no root over its sum, so its left
  side is a clock maximum r.m.s. and its right side a mean of squares. The two
  formulas are printed as alternatives for the same quantity and differ in
  nothing but the count they average over, so both need the root or neither
  does; Formula (A.2) beneath them takes $KB^2_\mathrm{FTm,j}$ as the mean of the
  squares, which is what the right side of (A.1b) is, and the worked Example
  8 on printed page 17 applies (A.1b) with the root: $KB_\mathrm{FTm,1} =
  \sqrt{\tfrac{1}{3}(0.92^2 + 0.6^2 + 0.9^2)} = 0.82$ "aus Gleichung
  (A.1b)". Either the root was lost from (A.1b) or its left side should read
  $KB^2_\mathrm{FTm,j}$.
- **Evidence:** the two formulas on printed page 11 and the example on
  printed page 17. Verified on PDF page 11 (printed p. 11) and PDF page 17
  (printed p. 17) of DIN 4150-2:1999-06: the radical of (A.1a) is drawn and
  that of (A.1b) is absent on the page.
- **Consequence for the standard's own tables:** none; the example that uses
  the formula uses the correct one.
- **Library behaviour:**
  [`railway_takt_max_rms`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/people.py)
  takes the root, and the tests hold it to the 0.82 and 0.22 of Example 8.
- **Status:** unreported.

## E DIN 4150-2:2023-08, Annex B, Example 9 (the night assessed over 920 clock intervals instead of 960)

- **Location:** B.9.3.3, the two night-time formulas on printed page 44 (PDF
  page 44 of the copy read here, which prints its folios without an offset),
  against 6.5.3.2 on printed page 19.
- **The print:** $KB_\mathrm{FTr,nachts} = \sqrt{\tfrac{1}{920} \cdot (12 \cdot
  (0{,}9 \cdot 0{,}24)^2 + 18 \cdot (1{,}0 \cdot 0{,}44)^2)} = 0{,}066$ for the
  case without the project and, with the same divisor, $0{,}096 > 0{,}07$
  for the planned case; the daytime formulas on the same page divide by 1920.
- **The problem:** 6.5.3.2 fixes $N_\mathrm{r}$ of Formula (6) at 1920 clock
  intervals by day and 960 by night, which is what 8 h of 30 s intervals
  are. The two night results reproduce 920 exactly, 0.0663 and 0.0957, and
  with 960 they are 0.0649 and 0.0937, which print as 0.065 and 0.094. The
  25 % test that follows, $0.096 > 1.25 \cdot 0.066 = 0.082$, becomes
  $0.094 > 1.25 \cdot 0.065 = 0.081$ and reaches the same conclusion.
- **Evidence:** the divisor 920 in both night formulas on printed page 44
  and the definition of $N_\mathrm{r}$ on printed page 19. Verified on PDF page 44
  (printed p. 44) and PDF page 19 (printed p. 19) of E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none; the example's
  conclusion holds either way.
- **Library behaviour:**
  [`train_assessment_severity`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/train_categories.py)
  divides the night by the 960 of 6.5.3.2, and the conformance rows of
  Example 9 compare with 0.065 and 0.094, saying what the print gives.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, Annex B, Figure B.2 b) (clock maxima printed on the figure that do not give the 0.39 the example uses)

- **Location:** Figure B.2 b) on printed page 33 (PDF page 33) and the text
  of B.4.3.3 on printed page 34.
- **The print:** the figure labels the ten clock intervals of hammer B with
  $KB_\mathrm{FTi}$ = 0,3; 0,41; 0,47; 0,43; 0,47; 0,37; 0,31; 0,04; 0,3; 0,41, and
  the text sets the 0,04 to zero and finds "$KB_\mathrm{FTmb}$ = 0,39".
- **The problem:** the r.m.s. of those ten values with the 0.04 as zero is
  $\sqrt{1.3759 / 10} = 0.371$, not 0.39. The labels of hammer A on the
  same figure do give the 0.16 the text uses. The 1999 edition's Figure C.3
  carried no labels and the 0.39 was inherited from it; the draft added the
  labels and they were not fitted to the number. Examples 4 and 5 use 0.39
  and their verdicts do not change with 0.37: 0.150 and 0.188 in place of
  0.154 and 0.195.
- **Evidence:** the ten labels on printed page 33 and, on printed page 34,
  the sentence "Somit ergibt sich aus Bild B.2." with the line
  "$KB_\mathrm{FTma}$ = 0,16 und $KB_\mathrm{FTmb}$ = 0,39" under it. Verified on PDF page 33 (printed p. 33) and PDF page 34
  (printed p. 34) of E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none; Examples 4 and 5
  conclude the same with either value.
- **Library behaviour:** the conformance rows of Examples 4 and 5 of the
  1999 edition, whose text and numbers the draft's Examples 4 and 5 repeat,
  take the 0.16 and 0.39 the text prints as inputs; nothing is read off the
  figure.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, Annex A, Figure A.1 (a decision drawn with its answer the wrong way round)

- **Location:** Figure A.1 on printed page 28 (PDF page 28), the diamond of
  the middle column below the dashed line, against the same figure of
  DIN 4150-2:1999-06, Figure B.1 on its printed page 12.
- **The print:** the diamond asks "KB-Werte > Stufe III?" and its "ja" exit
  leads to "Weiterer Betrieb ohne besondere Maßnahmen", its "nein" exit to
  "Weiterer Betrieb nur mit besonderen Maßnahmen".
- **The problem:** a value above stage III is the case that needs special
  measures, which is how the right-hand diamond of the same figure, with the
  same question, is drawn: "ja" to the special measures. The 1999 figure
  prints the middle diamond as "KB-Werte < Stufe III?" with the same exits,
  which reads correctly; the redrawn figure turned the comparison round and
  kept the exits.
- **Evidence:** the three diamonds below the dashed line on printed page 28
  of the draft and the middle diamond on printed page 12 of the 1999
  edition. Verified on PDF page 28 (printed p. 28) of E DIN 4150-2:2023-08
  and PDF page 12 (printed p. 12) of DIN 4150-2:1999-06.
- **Consequence for the standard's own tables:** none; the figure is a
  management flow and nothing in the standard is computed from it.
- **Library behaviour:** none; the flow of Annex A is not implemented.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, Annex B, B.9.3.1 (an extension assessed by the clause for a new line)

- **Location:** B.9.3.1 on printed page 42 (PDF page 42).
- **The print:** "Die Beurteilung erfolgt nach 6.5.3.5."
- **The problem:** 6.5.3.5 is the assessment of a line to be built new.
  Example 9 is the extension of an existing line by a second track, which
  is 6.5.3.6, and the example goes on to apply the 25 % rule of 6.5.3.6 to
  its Nullfall and Planfall.
- **Evidence:** the sentence on printed page 42, the heading of 6.5.3.5 on
  printed page 21 and of 6.5.3.6 on printed page 21. Verified on PDF page 42
  (printed p. 42) and PDF page 21 (printed p. 21) of E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none; the example applies
  the right clause.
- **Library behaviour:**
  [`assess_railway_change`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/train_categories.py)
  is 6.5.3.6 and its docstring names Example 9 as its worked case.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, 6.5.3.6 (requirements met when one condition holds, and an example that needs them all)

- **Location:** 6.5.3.6 on printed page 22 (PDF page 22 of the copy read
  here, which prints its folios without an offset), against B.9.3.3 and
  B.9.4 on printed page 44.
- **The print:** "Falls eine der folgenden Bedingungen für den
  Prognoseplanfall vorliegt, gelten die Anforderungen dieses Dokuments als
  eingehalten:", followed by a) for $KB_\mathrm{Fmax}$ by day, b) for
  $KB_\mathrm{Fmax}$ by night and c) for $KB_\mathrm{FTr}$, each met either by
  keeping to its guide value or by an increase under 25 % against the case
  without the project.
- **The problem:** read as printed, one condition is enough. Example 9 has
  b) met, "Für den Prognosefall bleibt der $KB_\mathrm{Fmax}$-Wert
  unverändert bei 0,66", an increase of nought, and still concludes in B.9.4
  that mitigation is to be looked into because $KB_\mathrm{FTr}$ by night exceeds
  $A_\mathrm{r}$ and grows by more than 25 %. The three letters are three assessments
  of two quantities, and the example applies every one that fits the case;
  "eine der" says the opposite.
- **Evidence:** the sentence and its three letters on printed page 22, and
  the unchanged 0.66 with the conclusion on printed page 44. Verified on PDF
  page 22 (printed p. 22) and PDF page 44 (printed p. 44) of
  E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none; the example reaches
  the conclusion the clause is for.
- **Library behaviour:**
  [`assess_railway_change`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/train_categories.py)
  requires every condition that applies, as the example does, and its
  docstring says why.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, 6.5.3.6 a) and b) (a maximum at the upper value itself, which neither dash takes)

- **Location:** 6.5.3.6 items a) and b) on printed page 22 (PDF page 22),
  against the bullets of 6.3 on printed pages 14 and 15, 5.4 on printed page
  13 and 6.5.1.1 on printed page 17.
- **The print:** a) "Wenn der $KB_\mathrm{Fmax}$-Wert < $A_\mathrm{o}$ (nach
  Tabelle 1); oder" and "wenn $KB_\mathrm{Fmax}$-Wert > $A_\mathrm{o}$ und Zunahme
  des $KB_\mathrm{Fmax}$-Wertes um < 25 % im Vergleich des Prognoseplanfalls
  zum Prognosenullfall"; b) "Wenn der $KB_\mathrm{Fmax}$-Wert den
  $A_\mathrm{o}$-Wert wie folgt unterschreitet", and then "Oder wenn bei einer
  Überschreitung des anzuwendenden oberen Anhaltswert $A_\mathrm{o}$ die
  Zunahme des $KB_\mathrm{Fmax}$-Wertes um < 25 % [...] ist".
- **The problem:** a maximum exactly at $A_\mathrm{o}$ is taken by neither
  dash of a): the first asks for less than $A_\mathrm{o}$, the second for
  more. b) leaves the same gap between "unterschreitet" (falls below) and
  "Überschreitung" (exceedance). The draft compares a maximum with
  $A_\mathrm{o}$ both ways. The second bullet of 6.3 fails it only above:
  "Ist $KB_\mathrm{Fmax}$ größer als der obere Anhaltswert $A_\mathrm{o}$,
  dann ist die Anforderung dieses Dokuments nicht eingehalten", and 6.5.1.1
  meets a rare event "kleiner oder gleich dem (oberen) Anhaltswert
  $A_\mathrm{o}$". But the third bullet of 6.3 meets a rare event when
  "$KB_\mathrm{Fmax}$ kleiner als $A_\mathrm{o}$ ist (siehe 6.5.1)", the
  fourth takes frequent events "bei denen $KB_\mathrm{Fmax}$ größer als
  $A_\mathrm{u}$, aber kleiner als $A_\mathrm{o}$ ist", its ANMERKUNG says
  the same, and 5.4 limits a substitute measuring point to "Nachweis der
  Einhaltung der Anhaltswerte $KB_\mathrm{Fmax}$ < $A_\mathrm{o}$". So the
  gap of 6.5.3.6 recurs in 6.3 itself: its second bullet does not fail a
  maximum at $A_\mathrm{o}$ and its fourth does not take it, while the third
  bullet and the 6.5.1.1 it points to disagree on it. The reading that
  closes the gap is "at or below $A_\mathrm{o}$" in the first dash of a)
  and of b), as the second bullet of 6.3 and 6.5.1.1 have it.
- **Evidence:** a comparison of sentences, each read on its page: 6.5.3.6 on
  PDF page 22 (printed p. 22), the second bullet of 6.3 on PDF page 14
  (printed p. 14), its third and fourth bullets and their ANMERKUNG on PDF
  page 15 (printed p. 15), 5.4 on PDF page 13 (printed p. 13) and 6.5.1.1 on
  PDF page 17 (printed p. 17) of E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none; no maximum of
  Examples 8 and 9 sits at $A_\mathrm{o}$.
- **Library behaviour:**
  [`assess_railway_change`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/train_categories.py)
  meets the condition of a) and b) at or below $A_\mathrm{o}$, as the second
  bullet of 6.3 and 6.5.1.1 read the upper value; the railway categories guide and its drawing
  of the 25 % rule say so beside the printed "<".
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, Annex B, B.8.3.4 (a result that its own four-decimal inputs do not give)

- **Location:** the last formula of B.8.3.4 on printed page 39 (PDF page
  39), against Table B.1 on printed page 38.
- **The print:** $KB_\mathrm{FTr} = \sqrt{\tfrac{1}{1920} \cdot (144 \cdot (1{,}0
  \cdot 0)^2 + 144 \cdot (1{,}0 \cdot 0)^2 + 80 \cdot (0{,}7 \cdot 0{,}406\,1)^2 +
  80 \cdot (0{,}7 \cdot 0{,}567\,6)^2)} = 0{,}099\,8 > 0{,}07$.
- **The problem:** with the four-decimal 0.406 1 and 0.567 6 the formula
  gives 0.099 72, which prints as 0.099 7; the 0.099 8 printed is what the
  three-decimal 0.406 and 0.568 of Table B.1 give, 0.099 76. The passages of
  Table B.1 themselves give 0.099 72. One unit in the fourth decimal, and
  the verdict, 0.07 exceeded, does not depend on it.
- **Evidence:** the formula and its result on printed page 39 and the
  r.m.s. values of Table B.1 on printed page 38. Verified on PDF page 39
  (printed p. 39) and PDF page 38 (printed p. 38) of E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none.
- **Library behaviour:** the conformance row of Example 8 compares
  [`train_assessment_severity`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/train_categories.py)
  from the 47 passages with 0.099 7 at half a unit of the fourth decimal,
  and says what the print gives.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, Annex B, B.4.3.3 (the clock maximum r.m.s. attributed to Formula (2))

- **Location:** B.4.3.3 on printed page 34 (PDF page 34), against 4.2.5 on
  printed page 12 and 6.4.2 on printed page 16.
- **The print:** "Wegen der Annahme, dass Bild B.2 repräsentativ für die
  gesamten Teileinwirkungszeiten $T_\mathrm{ea}$ und $T_\mathrm{eb}$ sei, gilt nach
  Gleichung (2):", followed by $KB_\mathrm{FTma} = \sqrt{\tfrac{1}{10} \sum_{i=1}^{10}
  KB^2_\mathrm{FTia}}$ and the same for hammer B.
- **The problem:** that is Formula (1) of 4.2.5, the clock maximum r.m.s.
  over $N$ intervals. Formula (2) of 6.4.2 is the assessment vibration
  severity from partial exposures, which the example applies two lines
  later, and the draft renumbered the 1999 edition's Formula (3), which the
  1999 example cited, as its (1).
- **Evidence:** the sentence on printed page 34, Formula (1) on printed page
  12 and Formula (2) on printed page 16. Verified on PDF page 34 (printed
  p. 34), PDF page 12 (printed p. 12) and PDF page 16 (printed p. 16) of
  E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none; the arithmetic is
  that of Formula (1).
- **Library behaviour:** none to take.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, Annex B, B.3.2 (a note cited under the clause it was moved out of)

- **Location:** the last bullet of B.3.2 on printed page 31 (PDF page 31),
  against the note under 6.3 on printed page 15.
- **The print:** "Es ist zu prüfen, ob das $A_\mathrm{r}$-Kriterium hier nicht zu
  berücksichtigen ist (siehe Anmerkung zu 6.2)."
- **The problem:** the note on the $A_\mathrm{r}$ criterion, the 4 h by day and 2 h
  by night above which a steady vibration makes $KB_\mathrm{FTr}$ not worth
  forming, is printed under 6.3 in the draft; 6.2 is the guide values. In
  the 1999 edition the same note stood under 6.2, the procedure, and the
  example's cross-reference was not moved with it.
- **Evidence:** the bullet on printed page 31, the note under 6.3 on
  printed page 15 and the heading of 6.2 on printed page 14. Verified on
  PDF page 31 (printed p. 31), PDF page 15 (printed p. 15) and PDF page 14
  (printed p. 14) of E DIN 4150-2:2023-08, and the note under 6.2 on PDF
  page 6 (printed p. 6) of DIN 4150-2:1999-06.
- **Consequence for the standard's own tables:** none.
- **Library behaviour:** none to take.
- **Status:** not reported; the document is a draft under comment.

## E DIN 4150-2:2023-08, 6.3 (a rare event met below the upper value in the prose and at it in the flowchart)

- **Location:** the fourth bullet of 6.3 on printed page 15 (PDF page 15),
  against 6.5.1.1 on printed page 17 and Figure 2 on printed page 15.
- **The print:** "Für selten auftretende, kurzzeitige Einwirkungen ist die
  Anforderung dieses Dokuments eingehalten, wenn $KB_\mathrm{Fmax}$ kleiner
  als $A_\mathrm{o}$ ist (siehe 6.5.1)"; 6.5.1.1 reads "wenn die maximale bewertete
  Schwingstärke $KB_\mathrm{Fmax}$ kleiner oder gleich dem (oberen)
  Anhaltswert $A_\mathrm{o}$ nach Tabelle 1 ist", and the diamond of Figure 2 asks
  "$KB_\mathrm{Fmax} \le A_\mathrm{o}$?".
- **The problem:** a rare event whose $KB_\mathrm{Fmax}$ equals $A_\mathrm{o}$ is
  met by the clause and the figure and not by the bullet that refers to
  them.
- **Evidence:** the bullet and the diamond on printed page 15 and the
  sentence of 6.5.1.1 on printed page 17. Verified on PDF page 15 (printed
  p. 15) and PDF page 17 (printed p. 17) of E DIN 4150-2:2023-08.
- **Consequence for the standard's own tables:** none.
- **Library behaviour:**
  [`assess_people_in_buildings`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/people.py)
  reads the boundary as the clause and the flowchart do, at or below.
- **Status:** not reported; the document is a draft under comment.

## DIN 4150-1:2001-06, Formulae (5) and (6) (a distance whose unit is printed as millimetres)

- **Location:** the symbol lists of Formula (5) on printed page 9 (PDF page
  9 of the copy read here, which prints its folios without an offset) and of
  Formula (6) on printed page 10.
- **The print:** "$R$ die Entfernung von der Sprengstelle, in mm;" under
  Formula (5) and "$R$ die Entfernung von der Fallstelle, in mm;" under
  Formula (6), each with "$R_0$ = 1 m (Bezugsgröße)" on the line below.
- **The problem:** the distance enters both formulas only as the ratio
  $R/R_0$ against a reference of 1 m, Formula (2) on printed page 5 defines
  $R$ "in m", and every distance axis of Annex A is in metres. A distance in
  millimetres against a reference in metres would put the ratio a thousand
  times too high.
- **Evidence:** the two symbol lists on printed pages 9 and 10 and the
  definition of $R$ under Formula (2) on printed page 5. Verified on PDF
  page 9 (printed p. 9), PDF page 10 (printed p. 10) and PDF page 5 (printed
  p. 5) of DIN 4150-1:2001-06.
- **Consequence for the standard's own tables:** none; the standard prints
  no values of $k$, $b$ or $m$ to compute anything with.
- **Library behaviour:**
  [`blast_peak_velocity_mm_s`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/vibration/immission/prediction.py)
  and `impact_peak_velocity_mm_s` take the distance in metres against the
  1 m reference, and their docstrings say the print has millimetres.
- **Status:** not reported.

## DIN 4150-1:2001-06, Clause 5.2.3 (a low working frequency written as a high one)

- **Location:** the first sentence on printed page 11 (PDF page 11), the
  third paragraph of Clause 5.2.3.
- **The print:** "Vibrationsbäre mit tiefer Arbeitsfrequenz ($f$ > 30 Hz)
  können …".
- **The problem:** a low working frequency cannot be one above 30 Hz, and
  the previous paragraph, on printed page 10, has just said that vibrators
  with high working frequencies, $f$ > 35 Hz, are the favourable ones. The
  sign is the wrong way round; the intended reading is a frequency below
  30 Hz.
- **Evidence:** the sentence on printed page 11 and the "$f$ > 35 Hz" of
  5.2.3 on printed page 10. Verified on PDF page 11 (printed p. 11) and PDF
  page 10 (printed p. 10) of DIN 4150-1:2001-06.
- **Consequence for the standard's own tables:** none.
- **Library behaviour:** none to take; the clause is prose.
- **Status:** not reported.

## DIN 4150-1:2001-06, Annex A, Figure A.2 (a legend that swaps two line styles)

- **Location:** Figure A.2 on printed page 18 (PDF page 18).
- **The print:** the legend reads "—— Ausgleichsgerade Z-Komponente" and
  "–·– Ausgleichsgerade X-Komponente", with ▽ for the Z and ○ for the X
  measurements.
- **The problem:** in the drawing the dash-dot line is the steepest of the
  three and runs through the ▽ markers, which are the Z values Figure A.1
  prints on printed page 17, from 6.90 mm/s at 270 m to 0.12 mm/s at
  1470 m; the continuous line is the flattest and runs through the ○
  markers of the X component. The dashed line and the □ markers of the Y
  component agree with their legend. The two styles are swapped between
  legend and drawing.
- **Evidence:** the lines and markers on printed page 18 against the Z
  peaks of printed page 17. Verified on PDF page 18 (printed p. 18) and PDF
  page 17 (printed p. 17) of DIN 4150-1:2001-06.
- **Consequence for the standard's own tables:** none; the figure is an
  illustration and Annex A says its numbers are not a basis for a
  prediction.
- **Library behaviour:** none to take.
- **Status:** not reported.

## DIN 4150-1:2001-06, Annex A, A.5.1 (an eccentric moment with the unit of a force)

- **Location:** the "Vorgang" line of A.5.1 on printed page 25 (PDF page
  25).
- **The print:** "Vibrator (Exzentermoment 320 N, Frequenz $f$ = 32 Hz)".
- **The problem:** an eccentric moment is a mass at a radius, in kg·m or
  N·m, which is how A.5.2 on printed page 27 prints its "statisches Moment
  5 kg · m"; a newton is a force. What was meant, 320 N·m or 32 kg·m,
  cannot be told from the page.
- **Evidence:** the line on printed page 25 and the moment of A.5.2 on
  printed page 27. Verified on PDF page 25 (printed p. 25) and PDF page 27
  (printed p. 27) of DIN 4150-1:2001-06.
- **Consequence for the standard's own tables:** none.
- **Library behaviour:** none to take; the case is an illustration.
- **Status:** not reported.

## DIN 4150-1:2001-06, Annex A, Figure A.18 (a point labelled all groups at the count of one hall)

- **Location:** Figure A.18 and its legend on printed page 33 (PDF page 33
  of the copy read here, which prints its folios without an offset),
  against Figure A.16 and A.8.1 on printed page 32.
- **The print:** the sixth measured point is drawn at about 110 machines and
  its legend reads "6) alle Gruppen"; A.8.1 says "Betrieb bis 252 Maschinen
  in zwei Maschinensälen", and the table of Figure A.16 counts 63, 7, 8, 6,
  57, 1, 23, 31, 12, 32, 4, 3 and 5 machines in the groups A to Ge, which is
  252.
- **The problem:** all groups are 252 machines, and 110 is what the groups
  E, F and G of the right-hand hall, the one nearest the measuring point,
  add up to (23, 31 and 56). The point before it, "Gruppen F und G", is at
  87 as those two add up, so the abscissa is the count of the groups
  running; the label of the sixth point is not.
- **Evidence:** the point and its legend on printed page 33, the sentence of
  A.8.1 and the table on printed page 32. Verified on PDF page 33 (printed
  p. 33) and PDF page 32 (printed p. 32) of DIN 4150-1:2001-06.
- **Consequence for the standard's own tables:** none; the text under the
  figure says the measured values stay put above about 60 machines because
  the groups switched on after that are farther off, which is what the
  figure shows either way.
- **Library behaviour:** none to take; the conformance rows of Figure A.18
  read the drawn curve, not the measured points.
- **Status:** not reported.