# Catalogue of air attenuation

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/catalogues/air-attenuation/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/catalogues/air-attenuation/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
Summary: The air attenuation coefficient, band by band, for the six temperature and humidity conditions a building standard's room model tabulates, in neper per metre.

---

The six conditions the building standard's own room model tabulates the air
attenuation for, and the coefficient in each of them, band by band. A room
model needs one. The air in a hall absorbs, the absorption grows with frequency
and with dryness, and by 8 kHz it is no longer a correction to the surfaces but
a term that decides the answer, which is why the model has an air term at all.
So the standard prints a short table of two temperatures crossed with three
ranges of relative humidity, and names the one to assume when the room's own
temperature and humidity are not known. That row carries a note here saying so.

The coefficient is a power attenuation in neper per metre, which is what the
standard's own air term takes, and it is not the decibel per metre an outdoor
propagation model works in. The page prints it in thousandths of a neper per
metre and so does this table. Six rows is all there is: this is a table to look
a value up in and not a model to interpolate, and the standard says nothing
about a room at 15 °C and 60 % that would let a row be made for it.

A note mark after a name or a value points to the note the page makes about that row or cell, listed under the table.

| Condition | 125 Hz (mNp/m) | 250 Hz (mNp/m) | 500 Hz (mNp/m) | 1 kHz (mNp/m) | 2 kHz (mNp/m) | 4 kHz (mNp/m) | 8 kHz (mNp/m) | Source |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 10 °C, 30-50 % | 0.1 | 0.2 | 0.5 | 1.1 | 2.7 | 9.4 | 29 | EN 12354-6:2003 Table 1 |
| 10 °C, 50-70 % | 0.1 | 0.2 | 0.5 | 0.8 | 1.8 | 5.9 | 21.1 | EN 12354-6:2003 Table 1 |
| 10 °C, 70-90 % | 0.1 | 0.2 | 0.5 | 0.7 | 1.4 | 4.4 | 15.8 | EN 12354-6:2003 Table 1 |
| 20 °C, 30-50 % | 0.1 | 0.3 | 0.6 | 1 | 1.9 | 5.8 | 20.3 | EN 12354-6:2003 Table 1 |
| 20 °C, 50-70 %[^airAttenuation-1] | 0.1 | 0.3 | 0.6 | 1 | 1.7 | 4.1 | 13.5 | EN 12354-6:2003 Table 1 |
| 20 °C, 70-90 % | 0.1 | 0.3 | 0.6 | 1.1 | 1.7 | 3.5 | 10.6 | EN 12354-6:2003 Table 1 |

[^airAttenuation-1]: The condition clause 4.3 recommends when the room's own temperature and humidity are not known.

## References

- **European Committee for Standardization. (2003).** [*Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 6: Sound absorption in enclosed spaces*](https://knowledge.bsigroup.com/products/building-acoustics-estimation-of-acoustic-performance-of-buildings-from-the-performance-of-elements-sound-absorption-in-enclosed-spaces) (EN 12354-6:2003).
  Table 1: the source of the rows of the catalogue of air attenuation that cite it.