Summary: Effects of vibration on structures (DIN 4150-3:1999-02).

---

Effects of vibration on structures (DIN 4150-3:1999-02).

A pile driver, a passing tram or a blast puts vibration into the ground, and
the question the neighbours ask is whether the building will crack. DIN 4150-3
answers it the way an engineering practice can afford to: not with a stress
calculation, but with **guideline values** (*Anhaltswerte*) for one measured
quantity, the peak particle velocity, drawn from a large body of measurements
on real buildings. Keep under them and damage of the kind the standard defines
has not been observed; exceed them and it does not follow that damage occurs,
only that the cheap check no longer settles the question and Clauses 4.2 to
4.4 have to be done properly.

**What is measured** (5.1). At the foundation, the largest of the three
components $v_x$, $v_y$, $v_z$ of the particle velocity, as
a peak, each treated on its own; the standard calls it
$|v_i|_\mathrm{max}$ and then writes it $v_i$. In the topmost
floor plane, the larger of the two horizontal components, measured at the
outside wall, which is the building's horizontal answer to the foundation
excitation rather than a new excitation.

**Short-term vibration** (Clause 5) is vibration that does not occur often
enough for resonance to build up in the structure. Table 1 gives its
guideline values by building class, and at the foundation they depend on
frequency: a building tolerates a fast wiggle better than a slow one, so the
value rises from 1 Hz to 100 Hz. Between the printed frequencies the
guideline is read off Bild 1, which joins the corner values by straight lines
on a linear frequency axis; above 100 Hz the 100 Hz value may be used. In the
topmost floor plane one value covers all frequencies.

**Long-term vibration** (Clause 6, *Dauererschütterungen*) is the opposite
case: often enough for the structure to respond at its own frequencies. Table
3 drops to a single value per class in the topmost floor plane, roughly a
quarter of the short-term one, and prints no frequency dependence at all.

**Buried pipelines** (5.3) are judged on their own Table 2 by pipe material,
measured on the pipe, and long-term vibration halves those values (6.3).

Three sizing rules travel with the tables and are here because a reader who
has the tables needs them in the same breath:

* Ceilings and floors (5.2) are separately covered by a vertical
  $v_z \leq 20$ mm/s at the point of largest vibration, usually mid-span.
* Massive engineering structures such as reinforced-concrete abutments and
  block foundations may take twice the row 1 values of Table 1 (5.1).
* The lowest horizontal natural frequency of a building of five storeys or
  more is roughly $f_i \approx 10/n$ with $n$ the storey count
  (6.4), which is the estimate that tells you whether the topmost floor plane
  will be excited at all. DIN 4150-1 prints it as Formula (4) and ISO 4866 in
  D.2, and [`story_fundamental_frequency`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#story_fundamental_frequency) is the one function for all
  three.

Clause 6.2 turns a measured velocity into a bending stress for a beam or a
one-way slab vibrating in one mode, which is the bridge from this guideline
check to the stress calculation of 4.2:

$$
\hat{\sigma}_\mathrm{max} = 1.73 \left(E_\mathrm{dyn} \, \varrho \, \frac{G_\mathrm{ges}}{G_\mathrm{balken}}\right)^{0.5} k_n \, \hat{v}_\mathrm{max} \tag{1}
$$

The guideline values are not limits in the legal sense and not an acceptance
specification. They are where experience says the question stops being worth
asking.

> Auto-generated from the source docstrings by `scripts/generate_api_docs.py` (`make api-docs`). Do not edit by hand.

## assess_building_vibration

```python
assess_building_vibration(
    velocity_mm_s: float,
    *,
    building_class: Literal['commercial', 'residential', 'sensitive'],
    frequency_hz: float | None = None,
    location: Literal['foundation', 'top_floor'] = 'foundation',
    duration: Literal['short_term', 'long_term'] = 'short_term',
    massive_structure: bool = False,
) -> DamageAssessment
```

Compare one measured peak velocity with its guideline value.

**Parameters**

| Name | Description |
| :--- | :--- |
| `velocity_mm_s` | The measured peak velocity, in millimetres per second; see [`DamageAssessment`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#damageassessment) for which component it is. Zero is accepted and keeps to every guideline value. |
| `building_class` | One of [`BUILDING_CLASSES`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#building_classes). One of `"commercial"`, `"residential"` or `"sensitive"`. |
| `frequency_hz` | Frequency of the dominant component, in hertz. Required for the short-term foundation case. |
| `location` | `"foundation"` (default) or `"top_floor"`. |
| `duration` | `"short_term"` (default) or `"long_term"`. |
| `massive_structure` | See [`guideline_velocity`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#guideline_velocity). |

**Returns:** The comparison, as a [`DamageAssessment`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#damageassessment).

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If the velocity is negative or not finite, or for any reason [`guideline_velocity`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#guideline_velocity) raises. |
| TypeError | if `velocity_mm_s` is not a single number, or `building_class`, `duration` or `location` is not a text. `frequency_hz` is refused the same way when it is not one real number. |

## bending_stress

```python
bending_stress(
    peak_velocity_m_s: float | np.floating[Any] | np.integer[Any],
    *,
    dynamic_modulus_pa: float,
    density: float,
    load_ratio: float = 1.0,
    mode_factor: float = 1.0,
) -> float

bending_stress(
    peak_velocity_m_s: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
    *,
    dynamic_modulus_pa: float,
    density: float,
    load_ratio: float = 1.0,
    mode_factor: float = 1.0,
) -> NDArray[np.float64]

bending_stress(
    peak_velocity_m_s: NumericArrayLike,
    *,
    dynamic_modulus_pa: float,
    density: float,
    load_ratio: float = 1.0,
    mode_factor: float = 1.0,
) -> float | NDArray[np.float64]
```

Peak bending stress from a peak velocity, Formula (1) of 6.2.

For a beam or a one-way slab of full rectangular section, constant
stiffness and uniform mass, vibrating in one mode, the peak bending
stress follows from the peak velocity alone:

$$
\hat{\sigma}_\mathrm{max} = 1.73 \left(E_\mathrm{dyn} \, \varrho \, \frac{G_\mathrm{ges}}{G_\mathrm{balken}}\right)^{0.5} k_n \, \hat{v}_\mathrm{max}
$$

The system dimensions do not enter, which is the point of the formula: a
velocity measured where the amplitude is largest is enough. The mode
factor $k_n$ lies between 1 and 1.3 in the technically important
cases, so it moves the answer by less than a third.

**Parameters**

| Name | Description |
| :--- | :--- |
| `peak_velocity_m_s` | Peak velocity over the beam length, in metres per second (scalar or array). Note the unit: the guideline tables are in millimetres per second and this formula is not. |
| `dynamic_modulus_pa` | Dynamic modulus of elasticity $E_\mathrm{dyn}$, in pascals. |
| `density` | Material density $\varrho$, in kilograms per cubic metre. |
| `load_ratio` | The load coefficient $G_\mathrm{ges}/G_\mathrm{balken}$, the beam's own weight plus any uniformly distributed load it carries over its own weight. 1 for a beam carrying nothing else. |
| `mode_factor` | The mode coefficient $k_n$, dimensionless. |

**Returns:** The peak bending stress, in pascals; a `float` for a number; an array for a sequence or an array, a zero-dimensional one included.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If a material property, the load ratio or the mode factor is not positive and finite, or a velocity is negative. |
| TypeError | if `density`, `dynamic_modulus_pa`, `load_ratio` or `mode_factor` is not a single number, or `peak_velocity_m_s` holds a text or a value that is not a real number. |

## BENDING_STRESS_CONSTANT

*Constant* (`float`).

```python
BENDING_STRESS_CONSTANT = 1.73
```

## BUILDING_CLASSES

*Constant* (`tuple`).

```python
BUILDING_CLASSES = ('commercial', 'residential', 'sensitive')
```

## BuildingDamageWarning

A DIN 4150-3 rule is used outside the range the standard offers it for.

Raised by [`story_fundamental_frequency`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#story_fundamental_frequency) below
[`STORY_FREQUENCY_MIN_STORIES`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#story_frequency_min_stories). The estimate is still returned:
DIN 4150-3 6.4 offers `10 / n` from about five storeys up, DIN 4150-1
Formula (4) for five and more, ISO 4866 D.2 for tall buildings, and below
five none of them says anything, so the number is an extrapolation
rather than the rule.

## DamageAssessment

```python
DamageAssessment(
    velocity_mm_s: float,
    building_class: Literal['commercial', 'residential', 'sensitive'],
    location: Literal['foundation', 'top_floor'],
    duration: Literal['short_term', 'long_term'],
    frequency_hz: float | None,
    *,
    massive_structure: bool = False,
)
```

One measured velocity against the guideline value it is judged by.

**Attributes**

| Name | Description |
| :--- | :--- |
| `velocity_mm_s` | The measured peak velocity, in millimetres per second: the largest of the three components at the foundation, or the larger of the two horizontal components in the topmost floor plane. |
| `building_class` | The row of Table 1 or Table 3 that was used. One of `"commercial"`, `"residential"` or `"sensitive"`. |
| `location` | Where the velocity was measured. One of `"foundation"` or `"top_floor"`. |
| `duration` | Which clause the guideline came from. One of `"short_term"` or `"long_term"`. |
| `frequency_hz` | The frequency the guideline was read at, or `None` where the guideline does not depend on frequency. |
| `massive_structure` | Whether the row 1 values were raised by [`MASSIVE_STRUCTURE_FACTOR`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#massive_structure_factor), the allowance 5.1 leaves to the assessor for a massive engineering structure. |

The guideline value (`guideline_mm_s`) is read from Table 1 or
Table 3 with those, so an assessment cannot be built against another
value.

### DamageAssessment.guideline_mm_s

*property*

The guideline value the velocity is compared with, in mm/s.

### DamageAssessment.plot()

```python
DamageAssessment.plot(
    ax: Axes | None = None,
    *,
    language: Literal['en', 'es'] = 'en',
    **kwargs: Any,
) -> Axes
```

Draw Bild 1 with this measurement on it.

The three foundation curves of Table 1 against frequency, and the
measured velocity as a point, so the margin is read rather than
computed.

Requires matplotlib (the `[plot]` extra); returns the
`Axes`.

**Parameters**

| Name | Description |
| :--- | :--- |
| `ax` | Existing axes, or `None` to create a figure. |
| `language` | Label language, `"en"` (default) or `"es"`. |
| `kwargs` | Forwarded to `phonometry._plot.vibration.plot_damage_assessment`. |

### DamageAssessment.ratio

*property*

The measured velocity as a fraction of the guideline value.

### DamageAssessment.within_guideline

*property*

Whether the measured velocity keeps to the guideline value.

True is the whole of what the standard promises: damage of the kind
4.5 defines has not, in the experience the tables are drawn from, been
observed. False is not the converse, and 5.1 says so: exceeding a
guideline value does not mean damage occurs, it means the question
has to be answered by 4.2 to 4.4 instead.

## FLOOR_VERTICAL_MM_S

*Constant* (`float`).

```python
FLOOR_VERTICAL_MM_S = 20.0
```

## FOUNDATION_FREQUENCIES_HZ

*Constant* (`tuple`).

```python
FOUNDATION_FREQUENCIES_HZ = (1.0, 10.0, 50.0, 100.0)
```

## foundation_guideline_curve

```python
foundation_guideline_curve(
    building_class: Literal['commercial', 'residential', 'sensitive'],
    frequency: NumericArrayLike | None = None,
) -> GuidelineCurve
```

Bild 1 as two arrays: frequency and guideline velocity.

The corner points of Table 1 by default, which is the polyline Bild 1
draws; pass *frequency* to sample the same polyline elsewhere.

**Parameters**

| Name | Description |
| :--- | :--- |
| `building_class` | One of [`BUILDING_CLASSES`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#building_classes). One of `"commercial"`, `"residential"` or `"sensitive"`. |
| `frequency` | Frequency or frequencies to sample at, in hertz, or `None` for the four corners of Table 1. |

**Returns:** The frequencies and the guideline velocities, as a [`GuidelineCurve`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#guidelinecurve).

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If the class is not one of the three, or a frequency is not positive and finite. |
| TypeError | if `building_class` is not a text, or `frequency` holds a text or a value that is not a real number. |

## guideline_velocity

```python
guideline_velocity(
    building_class: Literal['commercial', 'residential', 'sensitive'],
    frequency: float | np.floating[Any] | np.integer[Any] | None = None,
    *,
    location: Literal['foundation', 'top_floor'] = 'foundation',
    duration: Literal['short_term', 'long_term'] = 'short_term',
    massive_structure: bool = False,
) -> float

guideline_velocity(
    building_class: Literal['commercial', 'residential', 'sensitive'],
    frequency: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
    *,
    location: Literal['foundation', 'top_floor'] = 'foundation',
    duration: Literal['short_term', 'long_term'] = 'short_term',
    massive_structure: bool = False,
) -> NDArray[np.float64]

guideline_velocity(
    building_class: Literal['commercial', 'residential', 'sensitive'],
    frequency: NumericArrayLike | None = None,
    *,
    location: Literal['foundation', 'top_floor'] = 'foundation',
    duration: Literal['short_term', 'long_term'] = 'short_term',
    massive_structure: bool = False,
) -> float | NDArray[np.float64]
```

The guideline peak velocity of Table 1 or Table 3, in mm/s.

At the foundation for short-term vibration the guideline is a function of
frequency, read off Bild 1: constant below 10 Hz, then two straight
segments joining the corner values of Table 1 on a linear frequency axis,
and constant again above 100 Hz, since 5.1 allows the 100 Hz value to be
used for anything faster. Everywhere else Table 1 and Table 3 print one
number for all frequencies, and *frequency* is then not needed.

**Parameters**

| Name | Description |
| :--- | :--- |
| `building_class` | One of [`BUILDING_CLASSES`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#building_classes). One of `"commercial"`, `"residential"` or `"sensitive"`. |
| `frequency` | Frequency of the dominant component, in hertz (scalar or array). Required for the short-term foundation case, and refused for every other one, where the printed value is the same at every frequency and a frequency would govern nothing. |
| `location` | `"foundation"` (default) or `"top_floor"`. |
| `duration` | `"short_term"` (Table 1, default) or `"long_term"` (Table 3). |
| `massive_structure` | Raise the row 1 values by [`MASSIVE_STRUCTURE_FACTOR`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#massive_structure_factor), which is the most 5.1 allows a massive engineering structure. The allowance is written for row 1 of Table 1 alone, so it applies to the commercial class and to short-term vibration, and is refused anywhere else. |

**Returns:** The guideline peak velocity, in millimetres per second: a `float` without a frequency or for a number; an array for a sequence or an array, a zero-dimensional one included.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If a name is not one of its choices, if the short-term foundation case is asked for without a frequency, if a frequency is given for a case that does not read one, if a frequency is not positive and finite, or if *massive_structure* is asked for outside row 1 of Table 1. |
| TypeError | if `building_class`, `duration` or `location` is not a text, or `frequency` holds a text or a value that is not a real number. |

## GuidelineCurve

```python
GuidelineCurve(
    frequencies: NDArray[np.float64],
    velocities_mm_s: NDArray[np.float64],
)
```

A guideline velocity polyline of DIN 4150-3 Bild 1, sampled.

What [`foundation_guideline_curve`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#foundation_guideline_curve) returns: the frequencies and the
guideline velocities, named, where a `(frequency_hz, guideline_mm_s)`
tuple used to be unpacked by position.

**Attributes**

| Name | Description |
| :--- | :--- |
| `frequencies` | The frequencies, in hertz. |
| `velocities_mm_s` | The guideline velocity at each, in mm/s. |

## LONG_TERM_TOP_FLOOR_MM_S

*Constant* (`mapping`).

```python
LONG_TERM_TOP_FLOOR_MM_S = {'commercial': 10.0, 'residential': 5.0, 'sensitive': 2.5}
```

## MASSIVE_STRUCTURE_FACTOR

*Constant* (`float`).

```python
MASSIVE_STRUCTURE_FACTOR = 2.0
```

## pipeline_guideline_velocity

```python
pipeline_guideline_velocity(
    material: Literal['welded_steel', 'concrete_or_flanged_metal', 'masonry_or_plastic'],
    *,
    duration: Literal['short_term', 'long_term'] = 'short_term',
) -> float
```

The guideline peak velocity on a buried pipeline (Table 2), in mm/s.

Measured on the pipe itself; a substitute measurement at the ground
surface above it only estimates the value (5.3, D.1). Long-term vibration
halves the table, which is what 6.3 allows without further evidence.

**Parameters**

| Name | Description |
| :--- | :--- |
| `material` | One of [`PIPELINE_MATERIALS`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#pipeline_materials). One of `"welded_steel"`, `"concrete_or_flanged_metal"` or `"masonry_or_plastic"`. |
| `duration` | `"short_term"` (default) or `"long_term"`. |

**Returns:** The guideline peak velocity, in millimetres per second.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If a name is not one of its choices. |
| TypeError | if `duration` or `material` is not a text. |

## PIPELINE_LONG_TERM_FACTOR

*Constant* (`float`).

```python
PIPELINE_LONG_TERM_FACTOR = 0.5
```

## PIPELINE_MATERIALS

*Constant* (`tuple`).

```python
PIPELINE_MATERIALS = ('welded_steel', 'concrete_or_flanged_metal', 'masonry_or_plastic')
```

## PIPELINE_MM_S

*Constant* (`mapping`).

```python
PIPELINE_MM_S = {'welded_steel': 100.0, 'concrete_or_flanged_metal': 80.0, 'masonry_or_plastic': 50.0}
```

## SHORT_TERM_FOUNDATION_MM_S

*Constant* (`mapping`).

```python
SHORT_TERM_FOUNDATION_MM_S = {'commercial': (20.0, 20.0, 40.0, 50.0), 'residential': (5.0, 5.0, 15.0, 20.0), 'sensitive': (3.0, 3.0, 8.0, 10.0)}
```

## SHORT_TERM_TOP_FLOOR_MM_S

*Constant* (`mapping`).

```python
SHORT_TERM_TOP_FLOOR_MM_S = {'commercial': 40.0, 'residential': 15.0, 'sensitive': 8.0}
```

## STORY_FREQUENCY_MIN_STORIES

*Constant* (`int`).

```python
STORY_FREQUENCY_MIN_STORIES = 5
```

## STORY_FREQUENCY_NUMERATOR_HZ

*Constant* (`float`).

```python
STORY_FREQUENCY_NUMERATOR_HZ = 10.0
```

## story_fundamental_frequency

```python
story_fundamental_frequency(n_stories: int | np.integer[Any]) -> float
```

The rough lowest horizontal natural frequency of a building.

`f ~ 10 / n`, offered for buildings from about five storeys up. Three
documents print the same estimate: DIN 4150-3:1999-02 6.4 (the
`Stockwerkgleichung`, from about five storeys), DIN 4150-1:2001-06
Formula (4) (five storeys and more) and ISO 4866:2010 D.2 (the simplest
of the empirical formulae for tall buildings), so this is the one
function for all three. It is a rough estimate and the standards say so;
its use is to tell whether the excitation is anywhere near the frequency
at which the topmost floor plane will answer.

**Parameters**

| Name | Description |
| :--- | :--- |
| `n_stories` | The number of storeys `n`. |

**Returns:** The estimated lowest horizontal natural frequency, in hertz.

**Raises**

| Exception | When |
| :--- | :--- |
| TypeError | If `n_stories` is a bool, a text or an array rather than a number. |
| ValueError | If the storey count is not a whole number of at least 1. |

**Warns**

| Warning | When |
| :--- | :--- |
| BuildingDamageWarning | Below [`STORY_FREQUENCY_MIN_STORIES`](https://docs.jmrp.io/phonometry/reference/api/vibration/building-damage/#story_frequency_min_stories), where the estimate is an extrapolation of a rule the standard offers for taller buildings. |