# building.measurement.laboratory_insulation

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/api/building/laboratory-insulation/
Language: en
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-15
Updated: 2026-11-11T17:49:27Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Laboratory sound insulation of building elements (ISO 10140).

---

Laboratory sound insulation of building elements (ISO 10140).

This is the **laboratory** counterpart of the field ISO 16283 family in
[`phonometry.building.measurement.insulation`](https://docs.jmrp.io/phonometry/reference/api/building/insulation/). In a qualified test facility flanking
transmission is suppressed, so the *direct* airborne sound reduction index
`R` (not the apparent `R'`) is the primary quantity, and the receiving
room's equivalent absorption area `A` is a property of the known facility.

**Airborne sound reduction index (ISO 10140-2:2010).** From the
energy-average sound pressure levels in the source room `L1` and receiving
room `L2` this module forms, per one-third-octave band,
$R = L_1 - L_2 + 10 \log_{10}(S/A)$ (Clause 3.1, Formula (2)) with the free
test
opening area `S` and the Sabine equivalent absorption area
$A = 0.16\,V/T$ (ISO 10140-4:2010, Clause 4.6.3, Formula (5)). The
single-number weighted rating `Rw` and the adaptation terms `C` / `Ctr`
follow ISO 717-1 (Clause 5.3) through the verified
[`phonometry.building.weighted_rating`](https://docs.jmrp.io/phonometry/reference/api/building/ratings/#weighted_rating) engine, reused unchanged.

**Impact sound pressure level (ISO 10140-3:2010).** With the standard
tapping machine exciting the floor under test this module forms, from the
energy-average impact sound pressure level `Li` in the receiving room, the
normalized impact sound pressure level $L_\mathrm{n} = L_\mathrm{i} + 10 \log_{10}(A/A_0)$
(Clause 3.2,
Formula (1)) with $A = 0.16\,V/T$ and the reference absorption area
$A_0 = 10$ m². The single-number weighted rating `Ln,w` and the term
`CI` follow ISO 717-2 (Clause 5.3) through
[`phonometry.building.weighted_impact_rating`](https://docs.jmrp.io/phonometry/reference/api/building/ratings/#weighted_impact_rating), reused unchanged.

**Background-noise correction (ISO 10140-4:2010, Clause 4.3, Formula (4)).**
The receiving-room levels must be corrected for background noise before the
insulation is formed. [`background_correction`](https://docs.jmrp.io/phonometry/reference/api/building/laboratory-insulation/#background_correction) implements the correction
$L = 10 \log_{10}(10^{L_\mathrm{sb}/10} - 10^{L_\mathrm{b}/10})$ for a signal-to-background
margin
between 6 dB and 15 dB, the fixed 1.3 dB correction (limit of measurement)
for a margin of 6 dB or less, and no correction for a margin of 15 dB or
more. The 6/15 dB criteria are the laboratory analogue of the 6/10 dB
criteria of ISO 16283-1 Clause 9.2; both cap the correction at 1.3 dB.

**Frequency range (ISO 10140-4:2010, Clause 4.1).** Quantities are measured
over the mandatory one-third-octave range 100 Hz to 5000 Hz (optionally down
to 50 Hz). The single-number rating uses the core 100 Hz to 3150 Hz (16
one-third-octave bands) / 125 Hz to 2000 Hz (5 octave bands) range of
ISO 717-1/2, so the automatic rating is formed only when exactly 16 or 5
per-band values are supplied.

> Auto-generated from the source docstrings by `scripts/generate_api_docs.py` (`make api-docs`). Do not edit by hand.

## background_correction

```python
background_correction(
    signal_and_background: float | np.floating[Any] | np.integer[Any],
    background: float | np.floating[Any] | np.integer[Any],
) -> float

background_correction(
    signal_and_background: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
    background: NumericArrayLike,
) -> NDArray[np.float64]

background_correction(
    signal_and_background: float | np.floating[Any] | np.integer[Any],
    background: Sequence[float] | Sequence[np.floating[Any]] | Sequence[np.integer[Any]] | NDArray[np.bool_ | np.integer[Any] | np.floating[Any]],
) -> NDArray[np.float64]

background_correction(
    signal_and_background: NumericArrayLike,
    background: NumericArrayLike,
) -> float | NDArray[np.float64]
```

Correct receiving-room levels for background noise (ISO 10140-4:2010).

Applies the correction of Clause 4.3 per band from the combined
signal-plus-background level `Lsb` and the background level `Lb`,
using the margin `Lsb - Lb`:

- $\mathrm{margin} \ge 15$ dB: the background is negligible and
  the level is
  returned unchanged (Clause 4.3, quality requirement).
- $6\,\mathrm{dB} < \mathrm{margin} < 15\,\mathrm{dB}$: the level
  is corrected with Formula (4),
  $L = 10 \log_{10}(10^{L_\mathrm{sb}/10} - 10^{L_\mathrm{b}/10})$.
- $\mathrm{margin} \le 6$ dB: the fixed 1.3 dB correction is
  applied
  ($L = L_\mathrm{sb} - 1.3$); such bands are the *limit of measurement*
  and a
  [`LaboratoryInsulationWarning`](https://docs.jmrp.io/phonometry/reference/api/building/laboratory-insulation/#laboratoryinsulationwarning) is emitted (Clause 4.3). A *negative*
  margin ($L_\mathrm{b} > L_\mathrm{sb}$, i.e. background above the measured
  signal) falls
  in this branch and is likewise capped at $L_\mathrm{sb} - 1.3$: the
  band is
  simply flagged as the limit of measurement rather than yielding a
  nonsensical (or `NaN`) corrected level.

This is the sound-insulation counterpart of
[`phonometry.emission.background_noise_correction`](https://docs.jmrp.io/phonometry/reference/api/power/sound-power/#background_noise_correction) (ISO 3744:2010):
both apply the same energy subtraction
$10 \log_{10}(10^{L_\mathrm{sb}/10} - 10^{L_\mathrm{b}/10})$, but
that routine returns the correction *offset* `K1` (to subtract from
`Lsb`), whereas this one returns the already-corrected levels `L`
directly.

**Parameters**

| Name | Description |
| :--- | :--- |
| `signal_and_background` | Combined signal-plus-background levels `Lsb` per band, in dB. |
| `background` | Background-noise levels `Lb` per band, in dB. |

**Returns:** The background-corrected levels per band, in dB. A `float` when `signal_and_background` and `background` are both numbers, an array when either is a sequence or an array, a zero-dimensional one included.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If the shapes differ or contain non-finite values. |
| TypeError | if `background` or `signal_and_background` holds a text or a value that is not a real number. |

## laboratory_airborne_insulation

```python
laboratory_airborne_insulation(
    l1: NumericArrayLike,
    l2: NumericArrayLike,
    t2: NumericArrayLike,
    *,
    area: float,
    volume: float,
) -> LaboratoryAirborneInsulationResult
```

Laboratory airborne sound reduction index per ISO 10140-2:2010.

Computes, per frequency band, the sound reduction index
$R = L_1 - L_2 + 10 \log_{10}(S/A)$ (Clause 3.1, Formula (2)) with the
free test
opening area `S` and the Sabine equivalent absorption area
$A = 0.16\,V/T$ (ISO 10140-4:2010, Formula (5)). When exactly 16
one-third-octave (100-3150 Hz) or 5 octave (125-2000 Hz) values are
supplied, the single-number weighted rating `Rw` with `C` / `Ctr`
is also formed via [`phonometry.building.weighted_rating`](https://docs.jmrp.io/phonometry/reference/api/building/ratings/#weighted_rating) (ISO 717-1).

`l1` and `l2` may be one value per band (already energy-averaged) or a
two-dimensional `(positions, bands)` array, in which case the positions
are energy-averaged (ISO 10140-4:2010, Formula (2)). The band levels are
assumed already corrected for background noise (see
[`background_correction`](https://docs.jmrp.io/phonometry/reference/api/building/laboratory-insulation/#background_correction)).

**Parameters**

| Name | Description |
| :--- | :--- |
| `l1` | Source-room sound pressure levels, in dB. |
| `l2` | Receiving-room sound pressure levels, in dB. |
| `t2` | Receiving-room reverberation time per band, in seconds. |
| `area` | Area `S` of the free test opening, in m². |
| `volume` | Receiving-room volume `V`, in m³. |

**Returns:** [`LaboratoryAirborneInsulationResult`](https://docs.jmrp.io/phonometry/reference/api/building/laboratory-insulation/#laboratoryairborneinsulationresult) with `r`, `absorption_area` and `rating`.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If the band counts of `l1`, `l2` and `t2` differ, if `area`/`volume`/`t2` are not positive, or if inputs are non-finite. |
| TypeError | if `area` or `volume` is not a single number, or `t2` holds a text or a value that is not a real number. |

## laboratory_impact_insulation

```python
laboratory_impact_insulation(
    li: NumericArrayLike,
    t2: NumericArrayLike,
    *,
    volume: float,
) -> LaboratoryImpactInsulationResult
```

Laboratory impact sound pressure level per ISO 10140-3:2010.

Computes, per frequency band, the normalized impact sound pressure level
$L_\mathrm{n} = L_\mathrm{i} + 10 \log_{10}(A/A_0)$ (Clause 3.2, Formula (1)) with the
Sabine
equivalent absorption area $A = 0.16\,V/T$ (ISO 10140-4:2010,
Formula (5)) and the reference absorption area $A_0 = 10$ m².
When exactly
16 one-third-octave (100-3150 Hz) or 5 octave (125-2000 Hz) values are
supplied, the single-number weighted rating `Ln,w` with `CI` is also
formed via [`phonometry.building.weighted_impact_rating`](https://docs.jmrp.io/phonometry/reference/api/building/ratings/#weighted_impact_rating) (ISO 717-2).

`li` may be one value per band (already energy-averaged) or a
two-dimensional `(positions, bands)` array, in which case the positions
are energy-averaged (ISO 10140-4:2010, Formula (2)). The band levels are
assumed already corrected for background noise (see
[`background_correction`](https://docs.jmrp.io/phonometry/reference/api/building/laboratory-insulation/#background_correction)).

**Parameters**

| Name | Description |
| :--- | :--- |
| `li` | Energy-average impact sound pressure levels, in dB. |
| `t2` | Receiving-room reverberation time per band, in seconds. |
| `volume` | Receiving-room volume `V`, in m³. |

**Returns:** [`LaboratoryImpactInsulationResult`](https://docs.jmrp.io/phonometry/reference/api/building/laboratory-insulation/#laboratoryimpactinsulationresult) with `l_n`, `absorption_area` and `rating`.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If the band counts of `li` and `t2` differ, if `volume`/`t2` are not positive, or if inputs are non-finite. |
| TypeError | if `volume` is not a single number, or `t2` holds a text or a value that is not a real number. |

## LaboratoryAirborneInsulationResult

```python
LaboratoryAirborneInsulationResult(
    r: NDArray[np.float64],
    absorption_area: NDArray[np.float64],
    rating: WeightedRatingResult | None,
)
```

Per-band laboratory airborne sound insulation (ISO 10140-2:2010).

**Attributes**

| Name | Description |
| :--- | :--- |
| `r` | Sound reduction index $R = L_1 - L_2 + 10 \log_{10}(S/A)$ per band, in dB (Clause 3.1, Formula (2)). |
| `absorption_area` | Equivalent sound absorption area $A = 0.16\,V/T$ per band, in m² (ISO 10140-4:2010, Formula (5)). |
| `rating` | Single-number weighted rating `Rw` with `C` / `Ctr` (ISO 717-1), or `None` when the number of bands is neither 16 (one-third octave) nor 5 (octave) and no rating can be formed. |

### LaboratoryAirborneInsulationResult.plot()

```python
LaboratoryAirborneInsulationResult.plot(
    ax: Axes | None = None,
    *,
    language: Literal['en', 'es'] = 'en',
    **kwargs: Any,
) -> Axes
```

Plot `R` against the shifted ISO 717-1 reference curve.

Delegates to the weighted-rating plot (measured `R` versus the
shifted reference, unfavourable deviations shaded). Requires the
automatic rating to be available (16 or 5 bands) and matplotlib
(the `[plot]` extra); returns the
`Axes`.

**Parameters**

| Name | Description |
| :--- | :--- |
| `language` | The language of the labels: `"en"` or `"es"`. |

### LaboratoryAirborneInsulationResult.report()

```python
LaboratoryAirborneInsulationResult.report(
    path: str | os.PathLike[str],
    *,
    metadata: ReportMetadata | None = None,
    engine: Literal['reportlab'] = 'reportlab',
    verbose: bool = False,
    language: Literal['en', 'es'] = 'en',
) -> str
```

Render an ISO 10140-2 laboratory airborne-insulation report to a PDF.

Writes the one-page laboratory test report of ISO 10140-2:2010: the
standard-basis line, an optional metadata header block (client,
specimen, mounting, room volumes, climatic conditions ...), the band
table (16 one-third-octave or 5 octave bands) beside the
measured-versus-shifted-reference curve, the boxed laboratory rating
`Rw (C; Ctr)` (evaluated per ISO 717-1), the laboratory-method
statement, an optional verdict row and a footer with the identity
block and disclaimer. The report requires the single-number `rating`
to be present on the result; it is formed automatically only for
exactly 16 one-third-octave (100 Hz to 3150 Hz) or 5 octave (125 Hz to
2000 Hz) bands, and a result carrying no rating (any other band count)
is rejected.

**Parameters**

| Name | Description |
| :--- | :--- |
| `path` | Destination path of the PDF file. |
| `metadata` | Optional [`ReportMetadata`](https://docs.jmrp.io/phonometry/reference/api/building/insulation/#reportmetadata); `None` produces a lightweight fiche (body, rating, statement and disclaimer only). |
| `engine` | Rendering back end; only `"reportlab"` is supported. |
| `verbose` | When `True`, the table annexes the per-band equivalent sound absorption area `A` beside the reported `R`. |
| `language` | Fiche language: `"en"` (default, English) or `"es"` (Spanish, with a comma decimal separator). |

**Returns:** The written `path` as a `str`.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If `engine` is unknown, `language` is not one of the supported values, or the result carries no single-number rating (its band count is neither 16 one-third-octave nor 5 octave, so the ISO 717-1 rating the fiche needs was not formed). |
| ImportError | If reportlab is not installed (the `[report]` extra), or matplotlib is missing for the embedded rating figure (the `[plot]` extra). |

## LaboratoryImpactInsulationResult

```python
LaboratoryImpactInsulationResult(
    l_n: NDArray[np.float64],
    absorption_area: NDArray[np.float64],
    rating: ImpactRatingResult | None,
)
```

Per-band laboratory impact sound insulation (ISO 10140-3:2010).

**Attributes**

| Name | Description |
| :--- | :--- |
| `l_n` | Normalized impact sound pressure level $L_\mathrm{n} = L_\mathrm{i} + 10 \log_{10}(A/A_0)$ per band, in dB (Clause 3.2, Formula (1)). |
| `absorption_area` | Equivalent sound absorption area $A = 0.16\,V/T$ per band, in m² (ISO 10140-4:2010, Formula (5)). |
| `rating` | Single-number weighted rating `Ln,w` with `CI` (ISO 717-2), or `None` when the number of bands is neither 16 (one-third octave) nor 5 (octave) and no rating can be formed. |

### LaboratoryImpactInsulationResult.plot()

```python
LaboratoryImpactInsulationResult.plot(
    ax: Axes | None = None,
    *,
    language: Literal['en', 'es'] = 'en',
    **kwargs: Any,
) -> Axes
```

Plot `Ln` against the shifted ISO 717-2 reference curve.

Delegates to the weighted impact-rating plot. Requires the automatic
rating to be available (16 or 5 bands) and matplotlib
(the `[plot]` extra); returns the
`Axes`.

**Parameters**

| Name | Description |
| :--- | :--- |
| `language` | The language of the labels: `"en"` or `"es"`. |

### LaboratoryImpactInsulationResult.report()

```python
LaboratoryImpactInsulationResult.report(
    path: str | os.PathLike[str],
    *,
    metadata: ReportMetadata | None = None,
    engine: Literal['reportlab'] = 'reportlab',
    verbose: bool = False,
    language: Literal['en', 'es'] = 'en',
) -> str
```

Render an ISO 10140-3 laboratory impact-insulation report to a PDF.

Writes the one-page laboratory test report of ISO 10140-3:2010: the
standard-basis line, an optional metadata header block, the band table
(16 one-third-octave or 5 octave bands) beside the
measured-versus-shifted-reference curve, the boxed laboratory rating
`Ln,w (CI)` (evaluated per ISO 717-2), the laboratory-method
statement, an optional verdict row and a footer with the identity
block and disclaimer. The report requires the single-number `rating`
to be present on the result; it is formed automatically only for
exactly 16 one-third-octave (100 Hz to 3150 Hz) or 5 octave (125 Hz to
2000 Hz) bands, and a result carrying no rating (any other band count)
is rejected.

**Parameters**

| Name | Description |
| :--- | :--- |
| `path` | Destination path of the PDF file. |
| `metadata` | Optional [`ReportMetadata`](https://docs.jmrp.io/phonometry/reference/api/building/insulation/#reportmetadata); `None` produces a lightweight fiche (body, rating, statement and disclaimer only). |
| `engine` | Rendering back end; only `"reportlab"` is supported. |
| `verbose` | When `True`, the table annexes the per-band equivalent sound absorption area `A` beside the reported `Ln`. |
| `language` | Fiche language: `"en"` (default, English) or `"es"` (Spanish, with a comma decimal separator). |

**Returns:** The written `path` as a `str`.

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | If `engine` is unknown, `language` is not one of the supported values, or the result carries no single-number rating (its band count is neither 16 one-third-octave nor 5 octave, so the ISO 717-2 rating the fiche needs was not formed). |
| ImportError | If reportlab is not installed (the `[report]` extra), or matplotlib is missing for the embedded rating figure (the `[plot]` extra). |

## LaboratoryInsulationWarning

A laboratory insulation measurement at the limit of what it can show.

Emitted at the limit-of-measurement conditions of ISO 10140-4, and by the
ISO 15186-1 element-normalized intensity difference when it counts more
than one element unit, where it departs from the printed sign of
Formula (8) (see `docs/ERRATA.md`).