# Speech Transmission Index (STI)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/perception/speech/speech-transmission/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-10
Updated: 2026-11-16T21:36:14Z
Standards: IEC 60268-16:2020 (Edition 5); IEC 60268-16:2011
Verified: 14 conformance checks (IEC 60268-16:2020 (Edition 5); IEC 60268-16:2011) https://docs.jmrp.io/phonometry/reference/conformance/#speech-transmission-iec-60268-16
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: IEC 60268-16 speech transmission index (STI) in Python: modulation transfer function, the indirect method from an impulse response and direct STIPA.

---

A public-address system, an intercom, a reverberant lecture hall: each is a
*transmission channel* between a talker's mouth and a listener's ear, and each
degrades speech in its own way. The **Speech Transmission Index** (STI) of
IEC 60268-16 rates that channel with a single number in $[0, 1]$ by measuring
how much of the speech *envelope* survives the trip. This page covers the
modulation-transfer physics behind the index, the indirect method from a
measured room impulse response, and the direct STIPA measurement with its
standardized test signal.

**Note**

**STI vs SII.** The STI characterises a *transmission channel* (how much of
the speech modulation a room or sound system preserves) while the SII
predicts intelligibility from *audibility*: how much of the speech spectrum
clears the noise and the hearing threshold at the listener's ear. For the
latter, see the [Speech Intelligibility Index guide](https://docs.jmrp.io/phonometry/perception/speech/speech-intelligibility/).

## How do I compute the IEC 60268-16 Speech Transmission Index in Python?

From a measured room impulse response, call
`speech.sti_from_impulse_response(ir, fs, snr=25.0)`. The result gives `sti`
on the 0 to 1 scale, its Annex F `rating` letter and the seven octave-band
modulation transfer indices. For a direct measurement, play
`speech.stipa_signal(fs)` in the room and pass the recording to
`speech.stipa(recording, fs)`.

## 1. The modulation transfer function

Reverberation and noise do not muffle speech uniformly; they blur its
*envelope*: the slow (0.63–12.5 Hz) intensity modulations that carry
syllables. STI quantifies how much of that modulation survives from mouth
to ear, per octave band, as the **modulation transfer function** $m(F)$. A
delta-like channel keeps $m = 1$ (STI = 1); reverberation low-passes the
envelope following Schroeder's closed form, and steady noise scales it:

$$
m(F) = \frac{1}{\sqrt{1 + \left(2\pi F\,\frac{T_{60}}{13.8}\right)^2}}
\cdot \frac{1}{1 + 10^{-\mathrm{SNR}/10}}
$$

Modulation *depth* is the thing worth measuring because intelligibility rides
on the depth of the envelope valleys, not on the loudness of the peaks. A
talker alternates energy bursts (vowels) with near-silences (stop gaps,
fricative onsets) at syllable rate, and a listener segments speech by hearing
those dips. A reverberant tail fills the dips from behind, since late energy
smears into the gaps; steady noise raises their floor. In both cases the
received modulation depth shrinks, and with it the contrast between speech
sounds, even when the average level barely changes. The full method probes
$m(F)$ at 14 modulation frequencies (0.63 Hz to 12.5 Hz in one-third-octave
steps) in each of the 7 octave bands from 125 Hz to 8 kHz, converts each $m$ to
an effective signal-to-noise ratio clipped to ±15 dB, and combines the
results, band-weighted, into the index: the STI is an effective SNR of the
*envelope*, mapped onto $[0, 1]$.

That is a claim about a waveform, so it is worth watching on one. The clip
below sends a fully modulated 4 Hz envelope (one syllable-rate burst and gap
per quarter second) through the 1 kHz octave band of a room, and lets first
the reverberation time and then the noise take it apart. The received trace is
the probe convolved with the very $h_k^2(t)$ the Schroeder integral above runs
on, so the depth $(\max - \min)/(\max + \min)$ you can measure off the screen
*is* the $m$ the library returns. Both halves are drawn at a constant received
mean, which is the whole point: a sound level meter pointed at any frame of
this clip reads the same number, and the index does not.

**Video:** [Reverberation and noise taking apart a speech-rate envelope](https://docs.jmrp.io/phonometry/media/anim_modulation_transfer.webm): A fully modulated four-hertz intensity envelope is received through the one-kilohertz octave band of a room. As the reverberation time sweeps from 0.30 to 2.50 seconds the peaks fall and the valleys fill toward a mean line that never moves, and the measured modulation depth falls from 0.90 to 0.26; the modulation transfer curve beside it drops at every one of the fourteen modulation frequencies, the seven band modulation transfer indices fall with it and the speech transmission index walks from 0.84 down to 0.40. Then, at a fixed one-second reverberation time, the speech-to-noise ratio sweeps from 25 to 0 decibels: a shaded noise floor rises under the trace instead, the mean still does not move, and the depth falls again to 0.28 for a speech transmission index of 0.36.

Two mechanisms, one quantity. Reverberation smears energy across the gaps, so the envelope shrinks about its mean; steady noise fills the gaps from below, so a floor rises under it. Neither changes the average level, and both destroy the contrast a listener segments syllables by.

The two degradations look nothing alike on that curve, which is why the index
needs the whole $m(F)$ rather than one number:

![Two panels of the modulation transfer function in the 1 kHz octave band, m against the fourteen modulation frequencies from 0.63 to 12.5 Hz on a logarithmic axis. Left: reverberation times of 0.3, 0.9 and 2.5 seconds give three low-pass curves whose corner moves down in frequency as the decay lengthens, each matched by the dashed closed-form Schroeder prediction, with the two STIPA modulation frequencies of this band marked at 2 and 10 Hz. Right: at a fixed 0.9 second reverberation time, speech-to-noise ratios of 20, 10 and 0 dB scale the same noise-free curve down by a factor that does not depend on modulation frequency, the 0 dB curve sitting at about half the noise-free one](https://docs.jmrp.io/phonometry/media/sti_mtf_curves.svg)

*Reverberation and noise degrade the same quantity in two distinguishable ways.
A decay is a low-pass filter on the envelope, and lengthening it moves the
corner down (the dashed lines are the closed form above, which the measured
points follow closely). Steady noise instead multiplies the whole curve by
$1/(1 + 10^{-\mathrm{SNR}/10})$, which is flat in $F$: at 0 dB that factor is
exactly one half. A single modulation frequency cannot tell the two apart,
which is why the full method probes fourteen of them and STIPA still probes
two per band (marked on the left panel for this band).*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import speech

fs = 48000
rng = np.random.default_rng(0)

# The 14 full-STI modulation frequencies (0.63 Hz to 12.5 Hz, third-octave).
MOD_FREQS = np.array([0.63, 0.80, 1.00, 1.25, 1.60, 2.00, 2.50,
                      3.15, 4.00, 5.00, 6.30, 8.00, 10.0, 12.5])


def decay(t60):
    n = np.arange(int(2.5 * t60 * fs))
    return rng.standard_normal(n.size) * np.exp(-6.9078 * n / fs / t60)


fig, (ax_t, ax_n) = plt.subplots(1, 2, figsize=(12.6, 5.2))
for t60 in (0.3, 0.9, 2.5):
    mtf = speech.sti_from_impulse_response(decay(t60), fs).mtf[3]   # 1 kHz
    ax_t.semilogx(MOD_FREQS, mtf, "o-", label=f"T60 = {t60} s")
    closed = 1 / np.sqrt(1 + (2 * np.pi * MOD_FREQS * t60 / 13.8) ** 2)
    ax_t.semilogx(MOD_FREQS, closed, "--")

ir = decay(0.9)
for snr in (20.0, 10.0, 0.0):
    mtf = speech.sti_from_impulse_response(ir, fs, snr=snr).mtf[3]
    ax_n.semilogx(MOD_FREQS, mtf, "o-", label=f"SNR = {snr:g} dB")
ax_t.legend(); ax_n.legend()
plt.show()
```

![STI versus reverberation time with the IEC 60268-16 Annex F rating bands shaded](https://docs.jmrp.io/phonometry/media/sti_vs_t60.svg)

*The markers are full pipeline runs of `sti_from_impulse_response` on
synthesized decays; the dashed line is the analytic Schroeder prediction, so
their agreement is the indirect method's own sanity check. The shaded ladder
down the right margin is the Annex F qualification scale from U to A+, the
`rating` letter the result returns, so the curve reads directly as the class a
room of that reverberation time can reach.*

**Show the code for this figure**

```python
# Both features of the figure: the measured points against the closed form,
# and the Annex F ladder they are read against.
t60_points = [0.3, 0.5, 0.8, 1.2, 2.0, 3.0, 5.0]
alpha = np.array([0.085, 0.127, 0.230, 0.233, 0.309, 0.224, 0.173])  # Ed.5 male
beta = np.array([0.085, 0.078, 0.065, 0.011, 0.047, 0.095])


def analytic_sti(t60):
    m = 1 / np.sqrt(1 + (2 * np.pi * MOD_FREQS * t60 / 13.8) ** 2)
    snr_eff = np.clip(10 * np.log10(m / (1 - m)), -15.0, 15.0)  # the ±15 dB clip
    mti = np.full(7, ((snr_eff + 15.0) / 30.0).mean())
    return float(alpha @ mti - beta @ np.sqrt(mti[:-1] * mti[1:]))


measured = [speech.sti_from_impulse_response(decay(t), fs).sti
            for t in t60_points]
print(np.round(measured, 3))     # [0.83  0.738 0.652 0.557 0.436 0.368 0.27 ]

fig, ax = plt.subplots(figsize=(10, 6))
edges = [0.36, 0.40, 0.44, 0.48, 0.52, 0.56, 0.60, 0.64, 0.68, 0.72, 0.76]
letters = ["U", "J", "I", "H", "G", "F", "E", "D", "C", "B", "A", "A+"]
for lo, hi, letter in zip([0.15, *edges], [*edges, 0.95], letters):
    ax.axhspan(lo, hi, color=plt.get_cmap("RdYlGn")(letters.index(letter) / 11),
               alpha=0.18, lw=0, zorder=0)
    ax.text(1.005, (lo + hi) / 2, letter, transform=ax.get_yaxis_transform(),
            va="center", fontsize=8)
dense = np.logspace(np.log10(0.25), np.log10(6.0), 200)
ax.semilogx(dense, [analytic_sti(t) for t in dense], "--")
ax.semilogx(t60_points, measured, "o")
ax.set_xlabel("Reverberation time T60 [s]")
ax.set_ylabel("STI")
ax.set_ylim(0.15, 0.95)
plt.show()
```

## 2. Indirect and direct (STIPA) measurement

### Setting up the measurement

Both routes below start from a signal that travelled a real path, and clause 7
is specific about what produces it. The page covers two physically different
measurements: an unamplified talker in a room, and a sound system driven
electrically. The setup differs mainly in where the signal enters.

![Two panels of the physical STI measurement. Panel A, an unamplified talker: a room section with an artificial mouth on a stand at 1.5 m mouth height aimed along the speaking direction, a level callout of 60 dB(A) at 1 m in front of the mouth as the fallback when the operational speech level is not matched by the Annex J method, a measurement microphone at 1.2 m seated ear height with a keep-clear dimension from the nearest reflecting surface, a second ghosted receiver position further back, and a plan inset with several receiver positions spread over the seating. Panel B, a sound system: the same room with a ceiling loudspeaker line, an electrical injection arrow into the system input labelled level matched to speech by Annex J, microphones at listening height in two coverage zones, and an ambient-noise microphone with the system off. Both panels label the receiver omnidirectional, diffuse-field type, calibrated, and a footer strip reads: the rating of the space is the mean of the positions minus one standard deviation](https://docs.jmrp.io/phonometry/media/diagram_sti_setup.svg)

**The source.** For an unamplified talker, use an artificial mouth or mouth
simulator with head-and-mouth directivity (the standard points at ITU-T P.51),
because in a listening space intelligibility depends on the source directivity.
In its absence, a small single-source high-quality loudspeaker with a cone
diameter not exceeding 100 mm may be used, and it *shall* be described with the
results. Verify that the source's one-third-octave frequency response is within
±1 dB over the range the chosen signal needs (88 Hz to 11.3 kHz for a full-STI
or impulse-response signal, or octave band by octave band from 125 Hz to 8 kHz
for STIPA), measured in a free field, and equalize it if it is not. Then set it
on the axis of the microphone at the real talker position and distance, pointing
in the normal speaking direction (clause 7.2 a to c).

**The level.** Match the operational speech level with the Annex J procedure.
Where that match is not available, the standard's fallback is an equivalent
level of **60 dB(A) at 1 m in front** of the artificial mouth or test
loudspeaker. This is not a detail you can guess from the room: a close-talking
microphone sees a speech level of about 86 dB(A) to 94 dB(A) at 5 cm to 2 cm,
and a gooseneck about 80 dB(A) to 86 dB(A) at 10 cm to 5 cm (clause 7.2 d). For
a sound system the signal is injected electrically instead, as close to the
normal input as possible so that every equalizer, delay and processor in the
chain is included, and adjusted to the level of speech at that point by the
same Annex J method (clause 7.4).

**The receiver.** The measurement device (microphone, artificial ear, or head
simulator) shall be acoustically calibrated for sensitivity *and* frequency
response, and the measurement made at the listener's normal location and
listening height (about 1.2 m seated, 1.6 m standing). A single microphone
shall be omnidirectional and of diffuse-field type; a directional microphone
gives results that do not correlate with the STI model and is not advised
(clauses 4.1 and 7.3). For headsets, use an in-ear microphone or an artificial
ear. Measure the ambient noise at the same point with the source switched off,
so it can be entered through `ambient=` or as `snr=`.

**Before blaming the room**, verify the integrity of the test signal with a
loop-back measurement. This catches a corrupted or over-compressed file, and
the standard advises against digitally compressed formats, noting that schemes
of at least 128 kbit/s have been shown to work (clause 7.2 a).

```python
import numpy as np
from phonometry import speech

fs = 48000
# A measured room impulse response (synthesized decay so the example runs)
ir = np.random.default_rng(0).standard_normal(fs) * np.exp(-6.9 * np.arange(fs) / fs / 0.5)

# Indirect method: from a measured room impulse response
res = speech.sti_from_impulse_response(ir, fs, snr=25.0)
print(f"STI = {res.sti:.2f}  ({res.rating})")   # 0.73 (A)

# Direct STIPA measurement: play speech.stipa_signal() in the room, record it
test = speech.stipa_signal(fs, duration_s=18.0, level=80.0)
recording = test                       # in practice, the microphone signal after playback
res = speech.stipa(recording, fs)
res.plot()   # per-band modulation transfer index (MTI) bars, STI + rating in the title
```

**Where `snr=` comes from.** It is the second input of the indirect method and
it carries the whole noise degradation, so its provenance matters as much as
the impulse response's. For each octave band it is the band level of the speech
signal at the listener position minus the band level of the ambient noise
measured at that same position with the source switched off. This is why the
argument accepts a 7-vector: real ambient noise is rarely flat, and ventilation
noise concentrated at 125 Hz and 250 Hz costs the low bands far more than a
single broadband figure suggests. With `snr=None` the calculation assumes a
noise-free channel, so the result is the room's own limit and an *upper bound*
on what any listener will experience; quoting it as a measured STI is exactly
what makes a hall look acceptable on paper. Measure the ambient spectrum once,
measure or estimate the speech spectrum at the position, and pass the
band-by-band difference. Alternatively, when the absolute levels matter because
auditory masking and the reception threshold are in play, pass `levels=` and
`ambient=` instead so the level-dependent stages of the standard are applied
rather than a pure ratio.

Whichever route produced it, the result is worth reading band by band before
the single number is quoted: the STI is a weighted combination of seven
octave-band modulation transfer indices, and a room usually fails in a
particular part of the spectrum rather than uniformly.

![Modulation transfer index per octave band from 125 Hz to 8 kHz for a hall with a 0.9 s reverberation time and a 15 dB speech-to-noise ratio: the seven bars sit close together between about 0.54 and 0.60, giving STI = 0.58 with the Annex F rating E](https://docs.jmrp.io/phonometry/media/sti_band_mti.svg)

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from phonometry import speech

# A reverberant hall (T60 = 0.9 s) measured with a 15 dB speech-to-noise
# ratio: a synthesized exponential decay stands in for the measured IR.
fs = 48000
rng = np.random.default_rng(0)
n = np.arange(fs)
ir = rng.standard_normal(fs) * np.exp(-6.9078 * n / fs / 0.9)
res = speech.sti_from_impulse_response(ir, fs, snr=15.0)
print(round(res.sti, 3), res.rating)      # 0.584 E

# One line: the per-band MTI bars with the STI and its rating in the title.
res.plot()
plt.show()

# By hand, mirroring what STIResult.plot() draws:
bands = [125, 250, 500, 1000, 2000, 4000, 8000]
fig, ax = plt.subplots()
ax.bar(np.arange(len(bands)), res.mti)
ax.set_xticks(np.arange(len(bands)))
ax.set_xticklabels([f"{b}" for b in bands])
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Modulation transfer index MTI")
ax.set_ylim(0.0, 1.0)
ax.set_title(f"STI = {res.sti:.2f} (rating {res.rating})")
plt.show()
```

In this hall the seven indices sit within 0.06 of each other, the signature of
a decay that is uniform across the spectrum plus a broadband noise floor. A
profile that sags at 125 Hz and 250 Hz instead points at low-frequency
reverberation (too little bass absorption), while one that falls only at
4 kHz and 8 kHz usually means the loudspeaker is out of the listener's
direct-sound coverage, since air and directivity strip the top bands first.
Those are different remedies, and only the per-band view distinguishes them.

The direct measurement sends the STIPA signal along the full chain drawn below,
from the source through the room to the microphone and into the per-band
modulation analysis that yields the index.

![STI measurement chain: STIPA source signal through the room to the microphone and the MTF analysis](https://docs.jmrp.io/phonometry/media/diagram_sti_chain.svg)

`stipa` emits a `speech.STIWarning` when the recording is shorter than the
recommended 15 s (IEC 60268-16 STIPA practice, 15 s to 25 s): below that the
slow modulation components are averaged over too few periods and the STI is
biased low (an ideal loopback gives STI ≈ 0.956 at 5 s vs ≈ 0.998 at 18 s).

The implementation follows **Edition 5 (2020)**: Edition 4's normative PDF
is the base and every Ed. 5 change is source-attributed in the code; the
only numeric delta is the revised male speech spectrum of clause A.6.1.
CI checks the standard's own verification vectors: the six weighting-factor
band pairs to ±0.001 STI, the $m$ ↔ STI mapping table, the level-dependent
masking control points, and Schroeder-form decays at four $T_{60}$ values.

The analyzer is also verified end to end against the **IEC 60268-16 rev 5
verification test bench** signals from [stipa.info](https://stipa.info/)
(Embedded Acoustics BV): the direct-method modulation-depth staircase
(Annex C.3.2), the indirect-method exponential decays against the closed-form
Schroeder MTF (C.3.3), the filter-bank slope test with a +41 dB unmodulated
adjacent-octave tone (C.4.2, $m \ge 0.5$), the weighting-factor band pairs (A.2.2 of Edition 5)
and the filter-bank phase-distortion test with half-octave edge carriers
(A.3.1.2, |STI bias| < 0.01 over TI = 0.1–0.9). All five suites pass with the
level-dependent features disabled, as the bench prescribes. The 49 certified
WAVs stay local (third-party data, not committed); CI re-derives the same
signal constructions synthetically in the conformance suite.

### Reading the result: the Annex F bands

Every example on this page ends in a letter, and the letter is the part a
client reads. Annex F divides the scale into bands with edges at 0.36, 0.40,
0.44 … 0.76, and Annex G Table G.1 gives an example of what each band is used
for. `STIResult.rating` returns the letter; the nominal STI value below is the
centre of the band:

| Rating | STI range | Nominal | Typical use (Annex G Table G.1) |
| :--- | :--- | :--- | :--- |
| `A+` | ≥ 0.76 | — | Recording studios; excellent but rarely achievable |
| `A` | 0.72–0.76 | 0.74 | Theatres, speech auditoria, parliaments, courts, assistive hearing systems |
| `B` | 0.68–0.72 | 0.70 | Theatres, speech auditoria, teleconferencing |
| `C` | 0.64–0.68 | 0.66 | Complex messages with unfamiliar words |
| `D` | 0.60–0.64 | 0.62 | Lecture theatres, classrooms, concert halls |
| `E` | 0.56–0.60 | 0.58 | Concert halls, modern churches; high-quality PA |
| `F` | 0.52–0.56 | 0.54 | PA in shopping malls and public buildings, VA systems, cathedrals |
| `G` | 0.48–0.52 | 0.50 | **Target value for voice-alarm systems** |
| `H` | 0.44–0.48 | 0.46 | VA and PA in difficult acoustic environments; normal lower limit for VA |
| `I` | 0.40–0.44 | 0.42 | VA and PA in very difficult spaces |
| `J` | 0.36–0.40 | 0.38 | Not suitable for PA systems |
| `U` | < 0.36 | — | Not suitable for PA systems |

Three things follow. The familiar "STI ≥ 0.5" requirement of voice-alarm work
is band **G**, whose comment in Table G.1 is literally "target value for VA
systems"; Table G.1's own NOTE 1 adds that its values are minimum targets. The
scale is deliberately coarse (one band per 0.04 STI) because that spacing is
"based on the typical uncertainty of direct STI measurements", so a one-band
difference is the smallest worth arguing about and quoting three decimals of
STI is false precision. And 0.04 is *finer* than the ≈ 0.03 run-to-run scatter
of a single STIPA measurement noted below, so a letter can move between repeats
while the STI has not changed in substance. Annexes F and G are informative,
and Edition 5's Scope says outright that the document does not provide criteria
for certifying a transmission channel. Write a project requirement as a numeric
STI, and use the letter to report it.

### From positions to a rating for the space

The STI is a property of one source-to-listener path, so verifying a hall or a
voice-alarm installation is a *set* of measurements, not one. Put the
microphone at ear height for the intended posture (about 1.2 m seated, 1.6 m
standing), spread the positions over the served area including the
acoustically worst corners rather than the convenient ones, and keep at least
one position in each loudspeaker coverage zone of a distributed system: clause
7.6.4 asks for "a representative number of locations".

The reduction rule is the part that is easy to get wrong. Clause 7.6.4 says
that taking a simple mean of the results **can be misleading**, and that a
better single figure, one that accounts for the spatial variation, is the
**mean minus one standard deviation** (sometimes called the *rating of the
space*), the value a given location has about an 84 % probability of
reaching if the results are Gaussian. Better still is to plot the whole
statistical distribution. The practical consequence for a fiche: when a
`requirement` is set, say whether the boxed number is one position, the worst
position, or the mean minus one standard deviation (as those are three
different verdicts against the same limit). The 0.04-wide Annex F bands are
the natural resolution at which to summarise the spread.

### Direct or indirect: choosing between them

Each route has failure modes the standard is explicit about:

- **Non-linear or time-variant channels.** The indirect method assumes a
  linear, time-invariant channel: an impulse response cannot represent
  clipping, compressors, automatic gain control or a vocoder. For a sound
  system with non-linear processing in the chain, measure directly: the STIPA
  signal at least travels through the real chain, and the FULL STI signal is
  the reliable choice where the distortion is severe (IEC 60268-16 clause 6.3
  and Table 3).
- **Level-dependent effects.** The STI is not level-invariant: auditory
  masking and the reception threshold act on the *absolute* band levels at the
  listener. Play the test signal at the system's operating level (the
  standard's Annex J practice sets it 3 dB above the $L_\mathrm{Aeq}$ of continuous
  speech at the position) and pass `levels=` and `ambient=` so the analysis
  includes them; an impulse response measured loud and rescaled afterwards
  misses these effects entirely. Section 3 moves a measurement made at one
  level and noise condition to another.
- **Impulsive and fluctuating background noise.** A dropped tool or babble
  during a direct measurement corrupts the measured modulation depths
  (clause 7.13). The standard's remedy is the indirect route: average the
  impulse response with MLS or sweeps for a noise-free MTF, then add the noise
  degradation back via `snr=` or `levels=`/`ambient=`. A quick sanity check is
  to run the analyzer with the source off; the residual STI should stay below
  0.20.
- **Statistical spread.** The STIPA signal is pseudo-random noise, so repeated
  direct measurements scatter by up to about 0.03 STI even in steady
  conditions (and more in fluctuating noise); repeat and compare rather than
  trusting a single run, and respect the minimum duration flagged by the
  `speech.STIWarning` above.

The level dependence is the one of those four that is easy to dismiss, so it is
worth seeing how large it is:

![The STI of one fixed impulse response with a 0.9 second reverberation time, plotted against the overall speech level at the listener from 40 to 100 dB SPL with a fixed ambient noise spectrum. With level and ambient supplied the curve rises steeply from 0.25 at 40 dB, reaches a broad maximum of about 0.60 near 72 dB and falls back to 0.55 at 100 dB; without them the result is a flat dashed line at 0.610. The reception threshold is annotated at the low end and auditory masking at the high end, and the standard's fallback level of 60 dB(A) at 1 m is marked](https://docs.jmrp.io/phonometry/media/sti_level_dependence.svg)

*Same room, same impulse response, one number that changes by more than a third
of the scale. Below about 55 dB the speech is barely clear of the room's own
noise and the reception threshold of Table A.3 bites; above about 80 dB the
auditory masking of Table A.2 lets the loud low bands mask the high ones. In
between there is a broad plateau, which is why measuring at the operating level
is not fussiness: an impulse response measured loud and rescaled afterwards
sits on the flat dashed line and is only valid for a level nobody recorded.*

**Show the code for this figure**

```python
# `ir` and `fs` are the reverberant hall of this section.
ambient = np.array([45.0, 40.0, 35.0, 30.0, 28.0, 25.0, 22.0])   # dB SPL
# The Ed.5 male speech spectrum of clause A.6.1, relative to the 500 Hz band.
shape = np.array([-2.5, 0.5, 0.0, -6.0, -12.0, -18.0, -24.0])
shape_total = 10 * np.log10(np.sum(10 ** (shape / 10)))

totals = np.arange(40.0, 100.5, 2.5)
curve = [speech.sti_from_impulse_response(
    ir, fs, levels=shape - shape_total + t, ambient=ambient).sti for t in totals]
print(round(min(curve), 3), round(max(curve), 3))          # 0.246 0.604
print(round(speech.sti_from_impulse_response(ir, fs).sti, 3))   # 0.61

fig, ax = plt.subplots()
ax.plot(totals, curve)
ax.axhline(speech.sti_from_impulse_response(ir, fs).sti, linestyle="--")
ax.set_xlabel("Overall speech level at the listener [dB SPL]")
ax.set_ylabel("STI")
plt.show()
```

### `sti_from_impulse_response()` / `stipa()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `ir` / `x` | 1D array | any / Pa | non-empty | IR (indirect) or STIPA recording (direct) |
| `fs` | int | Hz | > 0 | |
| `snr` | float or 7-vector, optional | dB | default `None` | Adds steady-noise degradation |
| `levels` | 7-vector, optional | dB SPL | default `None` | Enables auditory masking + reception threshold (Tables A.2/A.3) |
| `ambient` | 7-vector, optional | dB SPL | needs `levels` | Ambient noise band levels |
| `reference` | 1D array, optional (`stipa`) | — | default `None` | Measured source signal instead of the nominal $m = 0.55$ |

Both return `STIResult`: `sti`, `mti` (7 bands), `mtf` (7×14 or 7×2),
`band_levels` and `ambient_levels` (the two spectra the corrections used, and
what section 3 reads to move the result to another condition), `rating`
(Annex F letter `A+`…`U`).

### IEC 60268-16 report (`.report()`)

`STIResult.report(path)` renders a one-page PDF fiche laid out like a
voice-alarm / public-address intelligibility verification report: a
standard-basis line stating the measurement method (the full STI indirect
method from an impulse response, or the direct STIPA method on a recorded
signal), an optional metadata header block, a per-octave-band modulation
transfer index table beside the per-band MTI bars (the result's own `.plot()`),
the boxed `STI = X` single number with the Annex F qualification band, an
optional verdict row and a footer with the fixed disclaimer. It uses the same
`ReportMetadata` container and rendering engine as the
[ISO 717 insulation fiche](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/#iso-717-report-report);
a supplied `requirement` is read as the minimum required STI (a higher STI
passes). Rendering needs reportlab and, for the figure the fiche embeds,
matplotlib (`pip install "phonometry[report,plot]"`); only `engine="reportlab"`
is supported. Pass `language="es"` for a Spanish fiche.

```python
from phonometry import ReportMetadata, speech

res = speech.sti_from_impulse_response(ir, fs)
res.report(
    "sti_fiche.pdf",
    metadata=ReportMetadata(
        specimen="Concourse voice-alarm loudspeaker line",
        measurement_standard="IEC 60268-16",
        laboratory="Phonometry Reference Laboratory",
        requirement=0.5,             # minimum required STI (a higher STI passes)
    ),
)
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [IEC 60268-16 STI example report (PDF)](https://docs.jmrp.io/phonometry/media/iec60268_16_sti_example.pdf): One-page speech-transmission-index fiche: a metadata header, an octave-band modulation transfer index table, the per-band MTI bars, the boxed STI = 0.64 single-number result with the Annex F qualification band and a PASS verdict against a 0.5 minimum.

Speech transmission index fiche (STIResult.report), STI with the Annex F band.

## 3. Occupancy noise and a different speech level

A hall is measured out of hours, empty, with the test signal at whatever level
the amplifier happened to be set to. The rating it has to meet is for the hall
in use: an audience in the seats, and the announcement at its operational
level. Annex M of IEC 60268-16 moves the measurement to that condition
arithmetically, in four steps and without a second visit:

1. **Acquire.** The modulation transfer matrix as measured, with the noise,
   masking and threshold of the measurement still in it, together with the
   speech and background-noise octave-band levels present while it was made.
2. **Remove.** Divide out the correction those levels produce, stripping the
   background noise, the auditory masking of Table A.2 and the reception
   threshold of Table A.3 back out and leaving the transmission channel alone.
3. **Reapply.** Multiply by the correction the operational levels produce,
   putting the occupancy noise, masking and threshold of the simulated
   condition in.
4. **Process.** Run the resulting matrix through the A.5.4 to A.5.6 chain of Edition 4
   into the index.

Taking the old condition out before putting the new one in is not ceremony,
and it is not an approximation either. The measured matrix is a product of two
things, and only one of them survives the move: the transmission channel, the
room's decay and the system's response, is what the empty measurement and the
occupied prediction have in common, while the noise, the masking and the
threshold belong to the listening condition and go with it. Those three cannot
be updated from how far the levels moved, either, because none of them is a
function of the change. Auditory masking is a piecewise function of the
*absolute* combined level of the band below, changing slope at 63 dB and again
at 67 dB and 100 dB, and the reception threshold of Table A.3 is an absolute
intensity that does not move at all. Both have to be re-derived at the new
levels, and dividing the old correction out is what leaves something to derive
them for.

The shortcut the two steps exist to forbid is the tempting one: running the
noise correction over the measured matrix again with the occupancy levels
counts the noise twice, because the measurement's own noise is already in
there. Note also where the truncation goes. The channel step 2 recovers can
exceed 1.0 in a band whose correction was strong, and it is not clamped between
the steps: the $m > 1$ truncation of A.5.3 NOTE 1 of Edition 4 is for the matrix about to be
processed, which is the one step 3 produces. The annex's own example never
tests that, its recovered matrix peaking at 0.997, but a measurement whose
correction bites harder would.

For the library the two steps are also one piece of code, which is the other
reason to keep them apart. Step 2 divides by the same factor of Edition 4 clause A.5.3 a
forward measurement multiplies by and step 3 multiplies by it, so the masking
of Table A.2 and the threshold of Table A.3 have a single implementation and
the adjustment cannot drift away from the measurement it adjusts.

```python
import numpy as np

from phonometry import speech

# The reverberant hall of this section, measured empty: a 0.9 s decay at
# 48 kHz stands in for the measured impulse response.
fs = 48000
rng = np.random.default_rng(0)
ir = rng.standard_normal(fs) * np.exp(-6.9078 * np.arange(fs) / fs / 0.9)

# The Ed.5 male speech spectrum of clause A.6.1 at 68 dB overall, and the
# empty hall's own ventilation noise, both in dB SPL per octave band.
band_shape = np.array([-2.5, 0.5, 0.0, -6.0, -12.0, -18.0, -24.0])
speech_empty = band_shape - 10 * np.log10(np.sum(10 ** (band_shape / 10))) + 68.0
noise_empty = np.array([42.0, 36.0, 31.0, 28.0, 25.0, 23.0, 21.0])

empty = speech.sti_from_impulse_response(
    ir, fs, levels=speech_empty, ambient=noise_empty
)
print(f"{empty.sti:.2f} ({empty.rating})")            # 0.60 (D)

# The audience in, and the announcement left where it was.
noise_occupied = np.array([54.0, 50.0, 47.0, 44.0, 40.0, 35.0, 30.0])
occupied = empty.adjusted_for_levels(
    operational_levels=speech_empty, operational_ambient=noise_occupied
)
print(f"{occupied.sti:.2f} ({occupied.rating})")      # 0.56 (F)

# The same room with the announcement 6 dB louder.
louder = empty.adjusted_for_levels(
    operational_levels=speech_empty + 6.0, operational_ambient=noise_occupied
)
print(f"{louder.sti:.2f} ({louder.rating})")          # 0.59 (E)
```

The occupancy noise costs two rating letters, and six decibels more from the
talker buys
one of them back. That is the argument for doing this before the handover
rather than after the complaint: the empty hall passed.

`STIResult.adjusted_for_levels()` reads the measurement condition off the
result, which is why it needs only the operational one and why it refuses a
result computed without `levels=`: such a result carries at most the flat
`snr=` noise factor, none of the level-dependent masking and threshold, and
no spectra to re-derive them from, so dividing the full correction out would
silently lower the answer. Where the matrix
comes from somewhere else, `speech.sti_adjusted_for_levels()` takes all four
spectra beside it.

Every result the adjustment returns is an ordinary `STIResult`, so the per-band
reading of section 2 applies to it, and it is worth taking. The single number
says the hall lost two letters; the bands say where it lost them:

![Modulation transfer index per octave band for the same hall in three conditions: measured empty (STI 0.60, rating D), adjusted for the audience (STI 0.56, rating F) and adjusted for the audience with the talker 6 dB louder (STI 0.59, rating E); a lower panel shows the change from the measured index, largest at 125 Hz where the occupied condition loses 0.07](https://docs.jmrp.io/phonometry/media/sti_occupancy_adjustment.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import speech

fs = 48000
rng = np.random.default_rng(0)
n = np.arange(fs)
ir = rng.standard_normal(fs) * np.exp(-6.9078 * n / fs / 0.9)

shape = np.array([-2.5, 0.5, 0.0, -6.0, -12.0, -18.0, -24.0])
talker = shape - 10 * np.log10(np.sum(10 ** (shape / 10))) + 68.0
empty_noise = np.array([42.0, 36.0, 31.0, 28.0, 25.0, 23.0, 21.0])
full_noise = np.array([54.0, 50.0, 47.0, 44.0, 40.0, 35.0, 30.0])

measured = speech.sti_from_impulse_response(ir, fs, levels=talker, ambient=empty_noise)
occupied = measured.adjusted_for_levels(
    operational_levels=talker, operational_ambient=full_noise
)
louder = measured.adjusted_for_levels(
    operational_levels=talker + 6.0, operational_ambient=full_noise
)

# One line: the adjusted result is an STIResult, so it draws its own bars.
occupied.plot()
plt.show()

# By hand, the three conditions on one band axis:
positions = np.arange(7)
fig, ax = plt.subplots()
for i, res in enumerate((measured, occupied, louder)):
    ax.bar(positions + (i - 1) * 0.27, res.mti, width=0.27,
           label=f"STI {res.sti:.2f} ({res.rating})")
ax.set_xticks(positions)
ax.set_xticklabels(["125", "250", "500", "1k", "2k", "4k", "8k"])
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Modulation transfer index MTI")
ax.set_ylim(0.0, 0.95)
ax.legend()
plt.show()
```

The 125 Hz band gives up the most, because that is where the audience is
loudest and the talker has least margin: about 7 dB of speech-to-noise there
against 16 dB at 500 Hz. The extra 6 dB then gives back most where most was
lost, nearly nine tenths of the 125 Hz loss against about half of the 1 kHz
one. Neither of those is visible in the index.

### What the adjustment cannot tell you

- **It moves the listening condition, not the room.** The channel step 2
  recovers is carried through untouched, so nothing an audience does to the
  acoustics is in the answer. Bodies and clothing absorb: the occupied
  reverberation time is shorter than the empty one, and the occupied channel is
  in truth *better* than the one measured. An empty-hall measurement is
  pessimistic about the reverberation and optimistic about the noise, and this
  corrects only the second. Where the audience changes the absorption
  materially, the honest route is an impulse response for the occupied room,
  measured or predicted, with the adjustment applied to that.
- **The operational speech level is an input, not a forecast.** The annex says
  what the STI would be if the talker or the amplifier delivered those band
  levels. Whether they will is a different question: a live talker lifts their
  voice in noise, a chain with a limiter or automatic gain control does not
  simply scale, and a system asked for 6 dB more may clip instead of delivering
  it, at which point it is no longer the linear channel the measured matrix
  stands for.
- **The noise it models is steady.** Occupancy noise is babble, which
  fluctuates and, being speech-shaped, masks in ways an intensity added per
  octave band does not represent. The standard's caution about fluctuating
  noise (clause 7.13) applies to the condition being simulated as much as to
  the one being measured.
- **The measurement's own spectra are what step 2 removes.** A wrong
  `measured_levels` or `measured_ambient` takes out the wrong correction, and
  step 3 has no way to notice; the adjusted matrix is then wrong in a direction
  nothing downstream reports. That is why `STIResult.adjusted_for_levels()`
  reads them off the result instead of asking again.
- **It is still one listener position.** Every spectrum in it is the one at the
  microphone, so an occupancy-adjusted result answers for that seat and no
  other.

### `sti_adjusted_for_levels()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `mtf` | (7, n) array | — | ≥ 0, finite | The matrix as measured, noise and masking included; values above 1 are truncated to 1, and above 1.3 warn that the measurement is likely invalid (Edition 4, A.5.3 NOTE 1) |
| `measured_levels` | 7-vector | dB SPL | required | Speech band levels during the measurement |
| `measured_ambient` | 7-vector, optional | dB SPL | default `None` | Background-noise band levels during the measurement |
| `operational_levels` | 7-vector | dB SPL | required | Speech band levels of the condition simulated |
| `operational_ambient` | 7-vector, optional | dB SPL | default `None` | Occupancy-noise band levels of that condition |

**Caution**

**Which edition this is.** What the library implements is the Edition 4 (2011)
Annex M procedure, verified against the printed intermediates of its Table M.1
worked example rather than only against the STI it ends on: both 98-value MTF
matrices, every scalar row on the way to them, the effective SNRs, the band
MTI row and the index. The only prints not used as oracles are the step 4
clamp and transmission-index matrices, which the annex derives from its own
rounded SNR print. The Edition 5 foreword says greater information is given
in Annex M about these adjustments (item g), and its table of contents grows
the annex from three printed pages to ten; the body of the Edition 5 annex
could not be obtained, so what those pages add beside this procedure is not
known here.

## What this guide covers

- **Covered.** IEC 60268-16:2020 (Edition 5) for the male speech option, the only one Edition
  5 keeps: the modulation transfer function and the m to STI mapping (clauses
  A.5.2 to A.5.6 of Edition 4), the full-STI indirect method from a measured impulse response
  via `speech.sti_from_impulse_response()`, the direct STIPA method of Annex B
  via `speech.stipa_signal()` and `speech.stipa()`, the Ed.5 male test-signal
  spectrum of clause A.6.1, the level-dependent auditory masking and reception
  threshold corrections of Tables A.2 and A.3 (`levels=` and `ambient=`), the
  Annex F rating letters returned as `STIResult.rating`, and the Edition 4
  Annex M adjustment of a measured result to occupancy noise and another speech
  level via `speech.sti_adjusted_for_levels()` and
  `STIResult.adjusted_for_levels()`.

- **Not covered.** The direct full-STI measurement (the 14-modulation-frequency test signal
  played and recorded through the real chain, per clause 6.3 and Table 3,
  recommended above when distortion is severe) is not implemented: only the
  STIPA direct signal (`stipa_signal`/`stipa`) and the indirect full-STI
  computation from an impulse response are available. The female speech option
  is not missing from the library: Edition 5 itself removed it (foreword, item
  d), so there is nothing left to implement. Whatever Edition 5 added to Annex M
  (foreword, item g: alternative noise and level adjustments) is neither covered
  nor ruled out, because that text could not be obtained.

## See also

- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the measured impulse response the
  indirect method consumes, and the open-plan metrics (ISO 3382-3) built on
  per-position STI.
- [Speech Intelligibility Index](https://docs.jmrp.io/phonometry/perception/speech/speech-intelligibility/): the
  audibility-based ANSI S3.5 index that complements the STI.
- [Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/loudness/) and
  [Sound Quality Metrics](https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/): loudness, sharpness, tonality and
  roughness of the received sound.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/perception/): the modulation-transfer derivation and the $m$ ↔ STI
  mapping.
- API reference: [`speech.sti`](https://docs.jmrp.io/phonometry/reference/api/speech/sti/).
- Theory: [Modulation transfer and STI](https://docs.jmrp.io/phonometry/reference/theory/perception/#modulation-transfer-and-sti-iec-60268-16): the modulation transfer function, why m is a ratio of modulation depths, and how the octave-band m matrix collapses to one index.

## References

- **Houtgast, T., & Steeneken, H. J. M. (1985).** A review of the MTF concept in room acoustics and its use for estimating speech intelligibility in auditoria. *The Journal of the Acoustical Society of America*, *77*(3), 1069-1077. https://doi.org/10.1121/1.392224
  The modulation-transfer framework of section 1 and the m ↔ STI mapping the index is built on.
- **International Electrotechnical Commission. (2011).** *Sound system equipment — Part 16: Objective rating of speech intelligibility by speech transmission index* (IEC 60268-16:2011).
  The fourth edition, whose normative text the implementation is built on beside the fifth. The errata registry records three defects of its Annex M worked example, Table M.1.
- **International Electrotechnical Commission. (2020).** [*Sound system equipment — Part 16: Objective rating of speech intelligibility by speech transmission index*](https://webstore.iec.ch/en/publication/26771) (IEC 60268-16:2020 (Edition 5)).
  The modulation transfer function and the m ↔ STI mapping, the STIPA test signal and direct method, the indirect method from the impulse response, auditory masking and the reception threshold (Tables A.2/A.3), the revised male speech spectrum (clause A.6.1), the Annex F rating letters and the Annex M adjustment for occupancy noise and speech level. Edition 4's normative PDF is the base and every Ed. 5 change is source-attributed, the only numeric delta being the revised male speech spectrum of clause A.6.1.