# Objective Intelligibility (STOI & ESTOI)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/perception/speech/objective-intelligibility/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/perception/speech/objective-intelligibility/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-19
Updated: 2026-11-16T21:36:10Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Correlation-based objective intelligibility of time-frequency weighted noisy speech: STOI (Taal et al. 2011) and ESTOI (Jensen & Taal 2016).

---

**STOI** and **ESTOI** are correlation-based objective intelligibility
measures. Each compares a clean reference to a degraded or processed version of
the same speech and returns a scalar with a monotonic relation to the fraction
of words a listener would understand: `1` when the degraded signal equals the
clean one, and near `0` for uncorrelated noise. They work directly on the two
waveforms, which makes them the standard yardstick for **time-frequency
weighted** speech: noise reduction, source separation and binary-mask
processing, where separating the clean speech from its distortion is not
straightforward. Neither measure is standardised: both are journal
algorithms, and the papers that define them (Taal et al. 2011 for STOI, Jensen
and Taal 2016 for ESTOI) are their normative text.

**Note**

**STOI/ESTOI vs STI vs SII.** STOI and ESTOI need the clean reference *and* the
degraded signal, and rate the processing between them. The
[Speech Transmission Index](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/) rates a
transmission channel from its impulse response, and the
[Speech Intelligibility Index](https://docs.jmrp.io/phonometry/perception/speech/speech-intelligibility/)
predicts audibility from speech, noise and hearing-threshold spectra. Use
STOI/ESTOI when you have a before/after pair.

**Caution**

`pystoi` (a public reimplementation of the authors' MATLAB) is used only as an
external cross-check in the test suite. phonometry reimplements both measures
from the two papers and never imports `pystoi` at runtime; the two agree to
well under `1e-3` on shared inputs.

## 1. The shared front end

Both measures run the same processing before they diverge (Taal et al. 2011,
Section II): resampling to **10 kHz**; a 256-sample (25.6 ms) Hann-windowed,
50 %-overlapping short-time transform zero-padded to 512 points; removal of the
frames whose *clean* energy is more than **40 dB** below the loudest clean
frame; a **15-band one-third-octave** grouping of the DFT magnitudes from a
lowest centre of 150 Hz; and **384 ms** (30-frame) analysis segments as the
unit of comparison, sliding one frame at a time and long enough to carry the
slow modulations that matter for intelligibility. The sample rate of the
inputs is free, the library resamples internally.

Both measures are defined for **running speech**, and the front end is where
that assumption bites: the 40 dB rule keys off the *clean* signal's dynamic
range, so it exists to stop the pauses between words from dominating the
correlation. A signal with no pauses (steady noise, a held tone, gapless
music) loses nothing to it and the index loses its meaning; a recording that
is mostly silence loses almost everything and the call raises rather than
returning a number. At least about **0.4 s of active speech** has to survive.

```python
import numpy as np
from phonometry import speech

fs = 10000
rng = np.random.default_rng(11)
n = 4 * fs
t = np.arange(n) / fs

# Speech-like material: band-limited noise under a 3.5 Hz syllabic envelope,
# so the front end's silent-frame rule has pauses to work on.
spectrum = np.fft.rfft(rng.standard_normal(n))
spectrum[(np.fft.rfftfreq(n, 1 / fs) < 200) | (np.fft.rfftfreq(n, 1 / fs) > 4000)] = 0
carrier = np.fft.irfft(spectrum, n)
clean = carrier * (0.15 + 0.85 * np.abs(np.sin(2 * np.pi * 3.5 * t)) ** 2)

noise = rng.standard_normal(n)
noise *= np.sqrt(np.mean(clean ** 2) / np.mean(noise ** 2))   # 0 dB SNR
degraded = clean + noise

d = speech.stoi(clean, degraded, fs)               # STOI, resampled to 10 kHz inside
print(round(d.value, 3))                    # 0.708
print(round(speech.stoi(clean, clean, fs).value, 6))   # 1.0  (a signal against itself)
```

Everything up to the 384 ms segments is shared; the two measures only part
ways at the correlation. The diagram lays the chain out with the numbers of
the flat-masker example.

![Block diagram of the STOI and ESTOI processing chain: a clean reference and a degraded version, in the guide's example speech-like material in a flat masker at 0 dB signal-to-noise ratio, are resampled to 10 kilohertz with silent frames dropped, transformed by a short-time DFT of 256-sample Hann frames at 50 percent overlap grouped into 15 one-third-octave bands from 150 hertz, and compared in 384 millisecond segments; the chain then splits into the STOI clipped envelope correlation and the ESTOI row- and column-normalised spectral correlation, and the example reads STOI equal to 0.727, with the lowest band keeping 0.27 of the correlation and the bands above 1.9 kilohertz reaching 0.90](https://docs.jmrp.io/phonometry/media/diagram_objective_intelligibility.svg)

### Getting a valid pair

The two arguments are not just "two signals". They must be the **same
utterance**, the **same length**, and **sample-accurate in alignment**. That
last one is the failure that costs most scores in practice, because
nothing in the result distinguishes it from genuine degradation. Both measures
correlate short-time envelopes inside 384 ms segments, so a constant delay
decorrelates them directly. On the pair above, rolling the degraded signal by
20 ms takes the score from 0.708 to 0.329; on a *perfect* pair, the same 20 ms
takes 1.0 to 0.459 and 50 ms drives it negative. Half a syllable is enough to
turn a good enhancement into a bad one on paper.

The library enforces equal length and nothing else: it does no alignment, so
the caller compensates any algorithmic latency first. Cross-correlate the
broadband envelopes (or prepend a short marker chirp), shift, then trim both to
the common span. If the two signals passed through separate playback and
capture clocks, watch for *drift* as well: a fixed shift cannot correct a
sample-rate offset, so resample to the reference clock or record through one
device. The check worth running once on any new pipeline is the pair of lines
above: `stoi(x, x, fs).value` is 1.0, and `stoi(x, np.roll(x, k), fs)` collapses
quickly with `k`.

What you do *not* have to match is level: the per-segment normalisation makes
both measures invariant to the gain of the degraded signal. Alignment is the
thing to get right; gain is not.

Three conditions raise instead of returning a value, and they are worth
recognising: unequal length, non-finite samples, and fewer than 30 short-time
frames surviving the silent-frame removal, which is the ~0.4 s of active
speech mentioned above.

### Capturing the degraded signal through a real device

Everything above assumes the degraded signal was produced numerically. Once it
is captured acoustically (a hearing aid on an artificial ear in a test box, a
headset, a loudspeaker-and-microphone loop), four things become the caller's
responsibility:

- **The clean reference stays the original file.** Re-recording it through the
  same chain removes the very distortion under test, and it also breaks the
  silent-frame selection, which is derived from the clean signal alone.
- **The capture chain is scored as degradation.** Loudspeaker response,
  background noise in the test box and microphone self-noise all enter the
  measured index, so measure the loop once with the device bypassed and report
  that number as the floor of the comparison.
- **Play at the device's operating level.** The *index* is invariant to level;
  the *device* is not. A compressor or a noise reducer behaves differently at
  a different input level.
- **Repeat.** A single capture carries the run-to-run variability of the
  acoustic path; quote the spread over several captures, not one number.

![The bench for an acoustically captured pair. A clean speech file forks into two paths: the upper one goes straight to the comparison, labelled the original file and never a re-recording; the lower one goes through a calibrated playback amplifier and loudspeaker into a test box holding the device under test, a hearing aid on an artificial ear or a headset on a torso simulator, and out through a capture microphone and preamplifier. Both paths meet at an align-and-trim block whose callouts read cross-correlate the envelopes, equal length and one clock, and only then enter the STOI and ESTOI chain. A dashed callout under the lower path says to run it once with the device bypassed, because the loudspeaker, the box noise and the microphone are scored as degradation too, and a footer says to play at the device operating level and repeat the capture](https://docs.jmrp.io/phonometry/media/diagram_stoi_bench.svg)

## 2. STOI: envelope correlation with clipping

For every band and segment STOI normalises the degraded envelope to the clean
one, clips it at a lower signal-to-distortion bound ($\beta = -15$ dB) so a
fully degraded unit cannot drag the score below its floor, and takes the sample
correlation of the two envelopes (Taal et al. 2011, Eqs. 3-6):

$$
d_{j,m} = \frac{\sum_n (x_j(n) - \bar{x}_j)\,(\bar{y}_j(n) - \bar{\bar{y}}_j)}
               {\lVert x_j - \bar{x}_j \rVert\,\lVert \bar{y}_j - \bar{\bar{y}}_j \rVert}.
$$

where $x_j(n)$ is the clean short-time temporal envelope of band $j$ at frame
$n$ inside the 30-frame segment $m$; $\bar{y}_j(n)$ is the *degraded* envelope
after the per-segment gain normalisation and the $\beta = -15$ dB clipping, so
that accent marks the processing and not a mean; a bar over a whole quantity
($\bar{x}_j$, $\bar{\bar{y}}_j$) is its mean over the segment; and
$\lVert\cdot\rVert$ is the Euclidean norm over the same 30 frames. So
$d_{j,m}$ is an ordinary Pearson correlation in $[-1, 1]$.

The index is the average of those intermediate correlations over all bands $j$
and segments $m$ (Eq. 6). The two marginals of that average are what
`band_scores` and `segment_scores` expose. Because the normalisation divides out a per-segment
gain, STOI is **invariant to the overall playback level** of the degraded
signal, and higher SNR gives a monotonically higher score.

```python
from phonometry import speech

# The speech-like `clean` of section 1, degraded at four signal-to-noise
# ratios. Keep the reference speech-like: a flat Gaussian reference has no
# pauses, so the 40 dB rule removes nothing and the index loses its meaning.
for snr_db in (-10, 0, 10, 20):
    g = 10.0 ** (-snr_db / 20.0)
    noisy = clean + g * rng.standard_normal(clean.size)
    print(snr_db, round(speech.stoi(clean, noisy, fs).value, 3))
# -10 0.083 | 0 0.484 | 10 0.858 | 20 0.956
```

The `STOIResult` carries the per-band mean correlation (`band_scores`) and the
per-segment scores (`segment_scores`) that average to `value`, and its
`.plot()` draws the per-band intermediate correlation. That per-band view is
worth looking at before quoting the index: it shows *where* the degradation
bites, which the single number cannot.

![Mean intermediate correlation per one-third-octave band from 150 Hz to 3810 Hz for speech-like material in a flat masker at 0 dB signal-to-noise ratio: the lowest band keeps only about 0.27 of the envelope correlation and the value climbs steadily to about 0.9 in the consonant bands above 1.9 kHz, averaging to a STOI of 0.727](https://docs.jmrp.io/phonometry/media/stoi_band_scores.svg)

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from scipy.signal import butter, lfilter
from phonometry import speech

# Speech-like material: band-limited noise with a 3.5 Hz syllabic envelope,
# in a flat masker at 0 dB SNR.
fs = 10000
rng = np.random.default_rng(11)
t = np.arange(4 * fs) / fs
b, a = butter(2, [200 / (fs / 2), 4000 / (fs / 2)], btype="band")
carrier = lfilter(b, a, rng.standard_normal(t.size))
clean = carrier * (0.15 + 0.85 * np.abs(np.sin(2 * np.pi * 3.5 * t)) ** 2)
masker = rng.standard_normal(clean.size)
gain = np.sqrt(np.mean(clean ** 2)) / np.sqrt(np.mean(masker ** 2))
res = speech.stoi(clean, clean + gain * masker, fs)
print(round(res.value, 3))    # 0.727

# One line: the per-band intermediate correlation behind the index.
res.plot()
plt.show()

# By hand, mirroring what STOIResult.plot() draws:
pos = np.arange(res.band_scores.size)
fig, ax = plt.subplots()
ax.bar(pos, res.band_scores)
ax.set_xticks(pos)
ax.set_xticklabels([f"{f:.0f}" for f in res.frequencies], rotation=45, ha="right")
ax.set_xlabel("One-third-octave band [Hz]")
ax.set_ylabel("Mean intermediate correlation")
ax.set_title(f"STOI = {res.value:.3f}")
plt.show()
```

The band profile is one marginal of the average; the other is time, and it
answers a question the band view explicitly cannot:

![Two stacked panels over four seconds. Top: the clean reference waveform with syllabic pauses, three of its 311 short-time frames shaded because they fall more than 40 dB below the loudest frame and are discarded, and a 0.35 second dropout region marked. Bottom: the per-segment STOI scores for two degradations of the same reference. Steady noise at 0 dB gives a flat series around 0.77 for a STOI of 0.772; a 0.35 second dropout leaves the series at 1.0 everywhere except a deep collapse to below zero across the dropout, and still averages to a higher STOI of 0.874](https://docs.jmrp.io/phonometry/media/stoi_segment_scores.svg)

*Two degradations of the same reference, and the scalar ranks them the wrong
way round: the dropout scores **0.874** against the steady masker's **0.772**,
because a short catastrophe averages away while a mild degradation everywhere
does not. The time marginal separates them immediately: one series is flat,
the other is perfect except for a handful of segments. That is the diagnostic to reach
for when a low STOI has no obvious cause: a transient, a dropout or a
processing artefact shows up here and nowhere else. The shaded frames at the
top are the ones the 40 dB rule discards, which is what "the input must have
speech dynamics" means concretely.*

**Show the code for this figure**

```python
# The same material as section 1 but with silence between the words, so some
# frames really do fall 40 dB below the loudest one.
fig_rng = np.random.default_rng(11)
freq = np.fft.rfftfreq(n, 1 / fs)
spec = np.fft.rfft(fig_rng.standard_normal(n))
spec[(freq < 200) | (freq > 4000)] = 0
env = np.abs(np.sin(2 * np.pi * 3.5 * t)) ** 2
ref = np.fft.irfft(spec, n) * np.where(env < 0.08, 0.0, env)

masker = fig_rng.standard_normal(n)
masker *= np.sqrt(np.mean(ref ** 2) / np.mean(masker ** 2))
steady = speech.stoi(ref, ref + masker, fs)

hole = np.ones(n)
hole[int(1.6 * fs):int(1.95 * fs)] = 0.0        # a 0.35 s dropout
dropout = speech.stoi(ref, ref * hole, fs)

print(round(steady.value, 3), round(dropout.value, 3))   # 0.772 0.874
print(round(float(dropout.segment_scores.min()), 3))     # -0.078
```

The flat masker costs the low bands most, because the speech spectrum falls
there while the masker does not, and the correlation recovers in the
consonant-bearing bands above 1 kHz. A band profile that is flat, or that
collapses only in one band, points at something other than broadband noise:
a notch filter, a resonance, or a processing artefact of the enhancement
under test.

## 3. ESTOI: spectral correlation for modulated maskers

ESTOI (`extended=True`) replaces the band-independent correlation with a joint
spectro-temporal one. Within each 384 ms segment it mean- and
variance-normalises the spectrogram **rows** (the band envelopes) and then its
**columns** (the per-frame spectra), and averages the correlation of the
normalised columns (Jensen and Taal 2016, Eqs. 4-8). Making the columns compete
means a masker that leaves quiet gaps, where the clean speech is briefly
audible, is credited for the speech glimpsed there, which STOI's per-band
average largely misses.

```python
# The steady-masker pair of the per-segment figure above, scored the other
# way: `extended=True` on the same call selects ESTOI.
estoi = speech.stoi(ref, ref + masker, fs, extended=True)
print(round(steady.value, 3), round(estoi.value, 3), estoi.extended)  # 0.772 0.417 True
```

On the same steady masker ESTOI reads well below STOI: the two indices are not
on one scale, so compare an ESTOI value with ESTOI values only.

![Two panels of intelligibility index versus SNR from -15 to 20 dB. Left (STOI): the stationary-masker and modulated-masker curves nearly overlap, so STOI barely separates the two maskers. Right (ESTOI): the modulated-masker curve sits clearly above the stationary one across the whole SNR range, so ESTOI credits the speech glimpsed in the masker's quiet gaps](https://docs.jmrp.io/phonometry/media/stoi_intelligibility.svg)

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from phonometry import speech

fs = 10000
rng = np.random.default_rng(20)
t = np.arange(3 * fs) / fs
# A speech-like clean signal: amplitude-modulated formant-ish tones.
clean = np.zeros_like(t)
for f0 in (200.0, 400.0, 700.0, 1100.0, 1800.0, 2600.0):
    depth = 0.5 * (1.0 + np.sin(2 * np.pi * rng.uniform(2.0, 6.0) * t + rng.uniform(0.0, 2 * np.pi)))
    clean += depth * np.sin(2 * np.pi * f0 * t + rng.uniform(0.0, 2 * np.pi))
p_clean = np.sqrt(np.mean(clean ** 2))

base = rng.standard_normal(clean.size)
gate = 0.5 * (1.0 + np.sign(np.sin(2 * np.pi * 5.0 * t)))   # 5 Hz on/off gate
modulated = base * (0.05 + 0.95 * gate)
snrs = np.arange(-15.0, 20.1, 5.0)

def curve(masker, extended):
    p_m = np.sqrt(np.mean(masker ** 2))
    return [speech.stoi(clean, clean + (p_clean / (p_m * 10.0 ** (s / 20.0))) * masker,
                        fs, extended=extended).value for s in snrs]

fig, (a, b) = plt.subplots(1, 2, figsize=(12, 5), sharey=True)
for ax, extended, title in ((a, False, "STOI"), (b, True, "ESTOI")):
    ax.plot(snrs, curve(base, extended), "o-", label="Stationary masker")
    ax.plot(snrs, curve(modulated, extended), "s--", label="Modulated masker")
    ax.set_title(title); ax.set_xlabel("SNR [dB]"); ax.set_ylim(0, 1); ax.legend()
a.set_ylabel("Intelligibility index")
plt.show()
```

### `stoi()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `clean` | 1-D array | any | non-empty | The clean reference; the measure is level-invariant, so calibration is irrelevant |
| `degraded` | 1-D array | any | same length as `clean` | Same utterance, same sample rate, sample-aligned |
| `fs` | int | Hz | > 0 | Sample rate of *both* signals; resampled to 10 kHz internally |
| `extended` | bool | — | default `False` | `True` selects ESTOI |

Returns a `STOIResult`: `value`, `band_scores` (15), `segment_scores`,
`frequencies` and `extended`. It raises on unequal lengths, on non-finite
input, and when fewer than 30 short-time frames survive the silent-frame
removal.

### Reading the value

The raw index has no absolute interpretation, and it is not meant to have one.
The mapping from $d$ to a percentage of words understood is a logistic fitted
to one corpus and one listener group (which the library deliberately does not
implement). So the same $d$ predicts different scores for different material,
and quoting "STOI = 0.73" as an intelligibility is a category error.

The working practice follows from that. Hold the material, the talkers, the
alignment and the analysis length fixed, and report the **difference** between
conditions (the ΔSTOI between a processor and its unprocessed input) together
with the number of utterances it was averaged over, because single-utterance
values scatter. Mind the shape as well: the index saturates near 1 for mild
degradations and flattens at the low end, so an improvement from 0.85 to 0.90
is worth far more in intelligibility than one from 0.35 to 0.40: monotonic
does not mean linear. And when two conditions score alike, the per-band and
per-segment views are the diagnostics that say whether they got there the same
way.

## 4. Which measure, and when

| | STOI | ESTOI |
| :--- | :--- | :--- |
| Intermediate quantity | Per-band envelope correlation, clipped | Row- and column-normalised spectral correlation |
| Level invariance | Yes (per-segment normalisation) | Yes (per-row and per-column normalisation) |
| Stationary maskers | Well validated | Well validated |
| Modulated maskers, competing talkers | Underrates the glimpsing benefit | Tracks it |
| Cost | Lower | A little higher |

For additive stationary noise the two measures are interchangeable and STOI is
the lighter default; when the interference fluctuates in time, or when
comparing processors that reshape the speech in time and frequency, prefer
ESTOI.

Both answer a narrower question than the two standardised speech metrics of
the library, and the choice between the three families is really a choice of
what you can measure. STOI and ESTOI need a *clean reference* and the
degraded signal, so they belong to processing work: noise reduction, source
separation, codecs, hearing-aid algorithms. The
[STI](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/) (IEC 60268-16) needs no clean
reference, only the channel, so it is what rates a room or a public-address
system. The [SII](https://docs.jmrp.io/phonometry/perception/speech/speech-intelligibility/)
(ANSI S3.5-1997) needs neither signal, only spectra, so it is what predicts
audibility for a listener with a given hearing threshold. When more than one
is available, they answer different questions rather than confirming each
other: a processor can raise STOI while the room keeps the STI poor.

## What this guide covers

- **Covered.** Taal et al. 2011 (STOI) and Jensen & Taal 2016 (ESTOI), the two
  correlation-based measures `stoi()` implements: the shared front end of 10 kHz
  resampling, 256-sample Hann frames, 15 one-third-octave bands, 384 ms segments
  and 40 dB silent-frame removal (Taal et al. 2011, Eqs. 1-4); the per-band
  envelope correlation and averaged index (Eqs. 5-6); and, with `extended=True`,
  the row- and column-normalisation of the spectrogram and the
  spectral-correlation index (Jensen & Taal 2016, Eqs. 4-8).

- **Not covered.** Taal et al. 2011 also fits a logistic function mapping the index $d$ to a
  predicted percentage of words understood, calibrated on specific
  listening-test corpora. `stoi()` returns only $d$, as `STOIResult.value`, not
  that percentage: the API has no percent-correct output or fitted coefficients.
  The 2010 ICASSP paper is cited only as the short conference version of the
  same algorithm, adding nothing implemented beyond the 2011/2016 equations
  above.

## See also

- [Speech Transmission Index](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/): rates a
  transmission channel from its impulse response or a STIPA recording.
- [Speech Intelligibility Index](https://docs.jmrp.io/phonometry/perception/speech/speech-intelligibility/):
  predicts intelligibility from speech, noise and hearing-threshold spectra.
- [Filter Banks](https://docs.jmrp.io/phonometry/signals/filters/filter-banks/): the one-third-octave bands
  the front end groups the DFT into.
- API reference: [`speech.objective_intelligibility`](https://docs.jmrp.io/phonometry/reference/api/speech/objective-intelligibility/).
- Theory: [Modulation transfer and STI](https://docs.jmrp.io/phonometry/reference/theory/perception/#modulation-transfer-and-sti-iec-60268-16): the modulation-transfer derivation the intrusive measures on this page are compared against.

## References

- **Jensen, J., & Taal, C. H. (2016).** An algorithm for predicting the intelligibility of speech masked by modulated noise maskers. *IEEE/ACM Transactions on Audio, Speech, and Language Processing*, *24*(11), 2009-2022. https://doi.org/10.1109/TASLP.2016.2585878
  ESTOI: the row- and column mean- and variance-normalisation of the short-time spectrogram (Eqs. 4-7) and the spectral-correlation intermediate index (Eq. 8).
- **Taal, C. H., Hendriks, R. C., Heusdens, R., & Jensen, J. (2010).** A short-time objective intelligibility measure for time-frequency weighted noisy speech. *2010 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)*, 4214-4217. https://doi.org/10.1109/ICASSP.2010.5495701
  The short conference version of STOI.
- **Taal, C. H., Hendriks, R. C., Heusdens, R., & Jensen, J. (2011).** An algorithm for intelligibility prediction of time-frequency weighted noisy speech. *IEEE Transactions on Audio, Speech, and Language Processing*, *19*(7), 2125-2136. https://doi.org/10.1109/TASL.2011.2114881
  STOI: the shared front end (10 kHz, 256-sample Hann frames, 15 one-third-octave bands, 384 ms segments), the normalisation and signal-to-distortion clipping (Eqs. 1-4), the per-band envelope correlation (Eq. 5) and the averaged index (Eq. 6).