# Prominent Discrete Tones (ECMA-418-1)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/perception/psychoacoustics/tone-prominence/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/perception/psychoacoustics/tone-prominence/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-10
Updated: 2026-11-16T21:36:13Z
Standards: ECMA-418-1:2024 (3rd ed.)
Verified: 2 conformance checks (ECMA-418-1:2024 (3rd ed.)) https://docs.jmrp.io/phonometry/reference/conformance/#prominent-discrete-tones-ecma-418-1
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: ECMA-418-1 tone-to-noise and prominence ratios: FFT verdicts for discrete tones, ECMA-74 positions and how to choose among four tonality metrics.

---

Tonal components in machinery noise are far more annoying than their level
suggests. ECMA-418-1:2024 (referenced by ECMA-74 Annex D) gives two FFT-based
methods to decide whether a discrete tone is *prominent*:
`tone_to_noise_ratio()` compares the tone level with the masking noise in its
critical band (clause 11), and `prominence_ratio()` compares the critical band
centred on the tone with the two contiguous bands (clause 12). Both return a
structured verdict against the frequency-dependent prominence criteria.

## 1. Tone-to-noise ratio and prominence ratio

```python
import numpy as np
from phonometry import psychoacoustics

fs = 48000
rng = np.random.default_rng(0)
t = np.arange(fs) / fs
x = np.sin(2 * np.pi * 1000 * t) + 0.05 * rng.standard_normal(fs)  # 1 kHz tone in noise
tnr = psychoacoustics.tone_to_noise_ratio(x, fs)            # highest peak, or tone_frequency=...
pr = psychoacoustics.prominence_ratio(x, fs, tone_frequency=1000.0)
print(round(tnr.ratio_db, 1), round(tnr.prominence_limit_db, 1), tnr.prominent)  # 45.6 8.0 True
print(round(pr.ratio_db, 1), round(pr.prominence_limit_db, 1), pr.prominent)     # 45.7 9.0 True

tnr.plot()   # the tone against its prominence criterion (needs matplotlib)
```

Three numbers, in that order: the ratio is the tone's excess over its masking
noise in decibels, the criterion is the frequency-dependent line it has to
clear, and `prominent` is the comparison of the two. Quote a result as
"TNR = 45.6 dB against an 8.0 dB criterion at 1 kHz, prominent by 37.6 dB",
never as a bare boolean: the margin is what tells a reviewer whether the
verdict survives the measurement uncertainty. (This synthetic tone is
absurdly prominent; the 250 Hz fan tone further down clears its criterion by
2.1 dB, which is the interesting case.)

The methods hinge on the **critical band**, the ear's analysis bandwidth,
$\Delta f_\mathrm{c} = 25 + 75\ [1 + 1.4(f/1000)^2]^{0.69}$ Hz (162 Hz at 1 kHz): a
tone is masked only by the noise *inside* its critical band, so both methods
focus on that band rather than the whole spectrum, but they use it
differently. The tone-to-noise ratio works within the band, separating its
spectral lines into tone and noise and subtracting their levels (clause 11,
Formulae 9–11); the prominence ratio instead compares the *whole* band centred
on the tone with the mean of its two contiguous critical bands (clause 12,
Formula 23):

$$
\mathrm{TNR} = L_\mathrm{t} - L_\mathrm{n}, \qquad
\mathrm{PR} = 10\,\log_{10}\!\frac{W_\mathrm{M}}{\tfrac{1}{2}(W_\mathrm{L} + W_\mathrm{U})}\ \text{dB},
$$

where $L_\mathrm{t}$ is the tone level (the energy sum of the tonal lines above the
band-edge baseline, Formula 9), $L_\mathrm{n}$ the level of the masking noise that
remains in the critical band, rescaled to the full critical bandwidth
(Formulae 10–11), and $W_\mathrm{M}$, $W_\mathrm{L}$, $W_\mathrm{U}$ the powers in the middle, lower and
upper critical bands (below $f_\mathrm{t} = 171.4$ Hz the truncated lower band is
rescaled to a 100 Hz bandwidth, Formula 24).

![Averaged spectrum of a tone in noise with the critical band shaded and the tone-to-noise ratio annotated against its prominence criterion](https://docs.jmrp.io/phonometry/media/tonality_spectrum.svg)

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from scipy.signal import welch
from phonometry import psychoacoustics

fs = 48000
rng = np.random.default_rng(21)
t = np.arange(30 * fs) / fs
x = (np.sqrt(2) * 0.1 * np.sin(2 * np.pi * 1000 * t)
     + 0.05 * rng.standard_normal(t.size))
res = psychoacoustics.tone_to_noise_ratio(x, fs)

# Averaged 1 Hz Hann spectrum (the clause 11.1 front end) and the
# critical band about the detected tone (edges approximated as +/- dfc/2):
f, p = welch(x, fs, window="hann", nperseg=fs, scaling="spectrum")
dfc = 25 + 75 * (1 + 1.4 * (res.frequency / 1000) ** 2) ** 0.69
sel = (f > 700) & (f < 1400)
plt.plot(f[sel], 10 * np.log10(p[sel]))
plt.axvspan(res.frequency - dfc / 2, res.frequency + dfc / 2, alpha=0.15)
plt.title(f"TNR = {res.ratio_db:.1f} dB (criterion {res.prominence_limit_db:.1f} dB)")
plt.xlabel("Frequency [Hz]"); plt.ylabel("Bin power [dB]")
plt.show()
```

The two methods cut the same spectrum in two different ways, and the cut is
what a hand check of a result has to reproduce. For the tone-to-noise ratio it
is made inside the critical band: the tone band is the run of lines between the
minima on either side of the peak, searched within 15 % of the critical
bandwidth, and only what stands above the straight line between its two end
lines counts as tone (clause 11.2, Formula 9).

![Two panels on the averaged spectrum of a 1 kHz tone in noise. Left, the critical band of the tone, 162.2 Hz wide from 922.2 Hz to 1084.4 Hz, shaded under the spectrum as the total level, with the window of 15 % of that width marked about the peak. Right, that window line by line, from 988 Hz to 1012 Hz: the tone band is the seven lines between the minima on either side of the peak, a dashed straight line joins its two end lines l1 and l2, and the area between that line and the spectrum is shaded as the tone. The heading gives a tone level of minus 28.0 dB, a masking noise level of minus 40.0 dB and a tone-to-noise ratio of 12.0 dB](https://docs.jmrp.io/phonometry/media/tone_to_noise_partition.svg)

For the prominence ratio the cut is made across three bands: the critical band
of the tone and the two that touch it, whose outer edges come from the fitted
Formulae 21 and 22. A tone at or below 171.4 Hz has its lower band cut at
20 Hz, and Formula 24 scales what is left of it to 100 Hz.

![Two panels, each an averaged spectrum cut into three shaded bands with the level of each written in it. Left, a 1 kHz tone: lower band from 782.5 Hz to 922.2 Hz at minus 40.5 dB, middle band from 922.2 Hz to 1084.4 Hz at minus 27.8 dB with the tone in it, upper band from 1084.4 Hz to 1261.5 Hz at minus 39.5 dB, and a prominence ratio of 12.2 dB by Formula 23. Right, a 120 Hz tone: the lower band is cut at 20 Hz and runs to 69.5 Hz, 49 Hz wide, at minus 45.0 dB, the middle band runs from 69.5 Hz to 170.5 Hz at minus 32.9 dB, the upper band from 170.5 Hz to 274.8 Hz at minus 42.0 dB, and the prominence ratio is 9.0 dB by Formula 24, which scales the lower band by 100 Hz over its width](https://docs.jmrp.io/phonometry/media/prominence_ratio_partition.svg)

A TNR at or above $8 + 8.33\log_{10}(1000/f_\mathrm{t})$ dB below 1 kHz (a flat 8 dB for
$f_\mathrm{t} \ge 1$ kHz) classifies the tone as *prominent*; the PR criterion is
$9 + 10\log_{10}(1000/f_\mathrm{t})$ dB below 1 kHz and 9 dB from there up, likewise
applied with $\ge$. Low frequencies get higher thresholds because wider
relative bands mask more.

`ToneAssessment.plot()` puts the verdict in its context: it draws the
criterion of the producing method over the whole 89.1 Hz to 11.2 kHz range of
interest and marks the assessed tone at its own frequency, so the margin that
decides the verdict is visible rather than implied.

![Tone-to-noise ratio of a 250 Hz fan tone plotted against the ECMA-418-1 prominence criterion: the criterion falls from about 17 dB at 89 Hz to a flat 8 dB above 1 kHz, and the assessed tone sits at 15.1 dB, 2.1 dB above the 13.0 dB criterion at 250 Hz, so it is prominent](https://docs.jmrp.io/phonometry/media/tone_prominence_assessment.svg)

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from phonometry import psychoacoustics

# A 250 Hz fan tone recorded in broadband machinery noise, 10 s at 48 kHz.
fs = 48000
rng = np.random.default_rng(4)
t = np.arange(10 * fs) / fs
x = (np.sqrt(2) * 0.011 * np.sin(2 * np.pi * 250.0 * t)
     + 0.03 * rng.standard_normal(t.size))
res = psychoacoustics.tone_to_noise_ratio(x, fs)
print(round(res.ratio_db, 1), round(res.prominence_limit_db, 1), res.prominent)
# 15.1 13.0 True

# One line: the tone against the criterion curve of its own method.
res.plot()
plt.show()

# By hand, mirroring what ToneAssessment.plot() draws:
f = np.logspace(np.log10(89.1), np.log10(11200.0), 400)
criterion = np.where(f < 1000.0, 8.0 + 8.33 * np.log10(1000.0 / f), 8.0)
fig, ax = plt.subplots()
ax.semilogx(f, criterion, color="#d62728", label="prominence criterion")
ax.plot([res.frequency], [res.ratio_db], "o", label="assessed tone")
ax.plot([res.frequency] * 2, [res.prominence_limit_db, res.ratio_db], ":", color="0.6")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Tone-to-noise ratio TNR [dB]")
ax.legend()
plt.show()
```

**When the two ratios disagree.** Near the criteria the verdicts can differ,
because each ratio is fragile in a different situation. TNR has to *split*
the critical band into tonal and noise lines first, so it degrades when that
separation is ambiguous: a tone riding a steep noise slope, or closely
spaced components whose skirts overlap. PR needs no separation, which makes
it the robust, automatable choice when **several tones share the critical
band** (they all land in $W_\mathrm{M}$); in exchange it reads low when a
*neighbouring* band also carries a tone (the flanking bands are then not
noise) and is biased on sharply sloping spectra, where the two flanking
bands no longer estimate the masking at the tone. In practice: prefer TNR
for a clean, isolated tone, prefer PR for multi-tone complexes sharing a
band, and report both when they straddle their criteria.

![Left: the ECMA-418-1 tone-to-noise and prominence criteria over the 89.1 Hz to 11.2 kHz range of interest, with the 250 Hz fan tone marked at 15.1 dB above its 13.0 dB TNR criterion and at 14.9 dB just below its 15.0 dB PR criterion. Right: the tone-to-noise ratio and the prominence ratio of a 1 kHz tone as a second tone grows in the next critical band up, the TNR flat at about 9.2 dB while the PR falls from 9.9 dB through its 9 dB criterion down to below minus 8 dB](https://docs.jmrp.io/phonometry/media/tnr_pr_comparison.svg)

*Two criteria, two failure modes. Left: the PR criterion sits about 1 to 2 dB
above the TNR one below 1 kHz, which is enough for the same 250 Hz fan tone to
be prominent by TNR (15.1 dB against 13.0 dB) and not prominent by PR (14.9 dB
against 15.0 dB). Right: a tone in the neighbouring critical band leaves the
TNR untouched and destroys the PR, because the flanking bands it treats as
noise are no longer noise.*

**Show the code for this figure**

```python
import numpy as np

# `psychoacoustics` is imported by the snippets above.
fs = 48000
rng = np.random.default_rng(7)
t = np.arange(8 * fs) / fs

# A 1 kHz tone in broadband noise, plus a second tone at 1160 Hz: outside the
# 162 Hz critical band around 1 kHz, so inside the upper contiguous band the
# prominence ratio uses as its noise estimate.
primary = np.sqrt(2) * 0.012 * np.sin(2 * np.pi * 1000.0 * t)
noise = 0.05 * rng.standard_normal(t.size)
for relative_db in (-24.0, -12.0, 0.0, 12.0):
    second = np.sqrt(2) * 0.012 * 10 ** (relative_db / 20)
    y = primary + second * np.sin(2 * np.pi * 1160.0 * t) + noise
    tnr_y = psychoacoustics.tone_to_noise_ratio(y, fs, tone_frequency=1000.0)
    pr_y = psychoacoustics.prominence_ratio(y, fs, tone_frequency=1000.0)
    print(relative_db, round(tnr_y.ratio_db, 1), round(pr_y.ratio_db, 1))
#   -24.0 9.2  9.8
#   -12.0 9.2  8.7
#     0.0 9.2  2.5
#    12.0 9.2 -8.6
```

**A tone that will not hold still.** Both methods assume the tone stays at one
frequency for the whole average. A fan or pump whose speed drifts smears the
tone across many bins: the tone band widens, part of the tone is counted as
masking noise, and the TNR reads low, while the PR is affected less but still
sees a smeared band. Clause 11.2 gives the diagnostic rather than leaving it to
judgement: if the tone band is wider than 15 % of the critical bandwidth,
repeat the analysis with a finer resolution, and a tone band that *stays* wider
than 15 % through that iteration indicates a tone of time-varying frequency or
another phenomenon. At that point the assessment is invalid rather than merely
uncertain. The remedies are upstream: stabilise the operating point of the
equipment under test, shorten each average and average the ratios instead of
the spectra, or order-track the rotating source. Harmonic complexes deserve the
same care component by component with `tone_frequency=`, since a drifting
fundamental drifts proportionally more at every harmonic.

## 2. Where to measure (ECMA-74), and what the ratios need

ECMA-74 is the emission standard that delegates its tone assessments to
ECMA-418-1, and it also fixes where the microphone goes around a device: one
operator position and four bystander positions. Phonometry implements the
ECMA-418-1 assessments, not the ECMA-74 measurement procedure, so the diagram
below is context for reading an emission declaration rather than something the
library performs.

![ECMA-74 emission measurement positions: seated operator microphone at 0.25 m and 1.20 m, and the four bystander positions at 1 m](https://docs.jmrp.io/phonometry/media/diagram_tonality_positions.svg)

**Which position's numbers are reported.** ECMA-418-1 clause 6 is explicit. If
the equipment has an operator position, measure there: at the loudest of them
when there is more than one, judged by the A-weighted level. If it has none,
measure at the bystander position with the highest A-weighted level *and* at
every other bystander position within 0.5 dB of it. The geometry comes from
ECMA-74:2025 clause 8.6: the operator microphone 0.25 m ± 0.03 m horizontally
from the reference box at 1.20 m ± 0.03 m seated or 1.50 m ± 0.03 m standing
(0.50 m for table-top equipment tested without its detachable keyboard, and
0.125 m at 1.0 m for hand-held equipment); at least four bystander positions
1.00 m ± 0.03 m from the sides of the reference box at 1.50 m ± 0.03 m above
the floor, with more added at 1.0 m intervals when a side exceeds 2.0 m. Where
several positions are measured, clause 6 requires the *highest* TNR and PR to
be reported together with the position each came from.

**With what.** A class 1 microphone chain per IEC 61672-1 into an FFT analyser
with linear (not exponential) RMS averaging and a Hanning window, calibrated
directly in dB re 20 µPa; the microphone oriented so that the incidence angle
is the one for which its response is flattest, which ECMA-74 clause 8.6.4 takes
as 30° or 45° below the horizontal in most practical cases. The measurement
interval must cover at least three operational cycles, or the complete sequence
for equipment that runs a sequence of varying cycles (ECMA-74 clause 7.7.2 via
8.7.2), and the background noise is corrected as ISO 11201 accuracy grade 2
requires.

**Resolution, in actionable terms.** Clause 7 asks for an FFT resolution below
1 % of the tone frequency, and recommends 0.25 % or better for the
tone-to-noise ratio, because experience has shown 1 % occasionally fails to
resolve the tone. At 250 Hz that is 0.63 Hz, so records of a second or more per
average; the library's 1 Hz default therefore satisfies the recommendation only
above about 400 Hz and is too coarse below it. Clause 11.2 adds the check that
matters at the far end: the tone band must not exceed 15 % of the critical
bandwidth, and if it does, the analysis is repeated finer.

**The weighting trap.** Clause 7 forbids any frequency weighting on the
analyser input, A-weighting included. Both ratios compare levels inside and
across critical bands, so a weighting curve tilts the comparison: harmless for
a TNR at 1 kHz, worth several tenths of a decibel for a PR at low frequency,
where the A-curve falls steeply across three consecutive critical bands. The
ratios are indifferent to *absolute* calibration but not to spectral shape,
which is why "calibration cancels out" is only half the story: the analyser
should still be calibrated absolutely, because the clause 8/9 threshold screen
below needs real sound pressure levels.

Proximate secondary tones in the same critical band are combined per
clause 11.6; for harmonic complexes assess each component (`tone_frequency=`).
Both methods work on Hann-windowed, RMS-averaged spectra and need no absolute
calibration for the ratio itself (the ratios are level differences).

### `tone_to_noise_ratio()` / `prominence_ratio()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D array | any (uncalibrated OK) | ≥ `fs/resolution_hz` samples | Ratios are level differences: calibration cancels out |
| `fs` | int | Hz | > 0 | |
| `tone_frequency` | float, optional | Hz | 89.1–11 200; default `None` | `None` assesses the highest peak in the range of interest |
| `resolution_hz` | float | Hz | > 0; default `1.0` | Tone band must stay within 15 % of the critical band (clause 11.2) |

Both return a `ToneAssessment(frequency, ratio_db, method)`, where `method`
says which ratio was taken (`"tone_to_noise_ratio"` or `"prominence_ratio"`);
`prominence_limit_db` and `prominent` are read from the standard's formula for that
ratio, so an assessment cannot carry another criterion.

## 3. Which tonality metric, and when

The library implements four tonality assessments, and they are not
interchangeable: each belongs to a different standard with its own purpose,
input and output.

| | TNR / PR | Tone audibility $\Delta L$ | Psychoacoustic tonality `T` | Wind-turbine tonal audibility |
| :--- | :--- | :--- | :--- | :--- |
| Standard | ECMA-418-1:2024, clauses 11 and 12 | ISO/PAS 20065:2016, adopted by ISO 1996-2:2017 Annex J | ECMA-418-2:2025, clause 6 | IEC 61400-11:2012, clause 9.5 |
| Question answered | Is this discrete tone prominent in the emission of a device? | Is the tone audible above the noise that masks it, and by how much? | How tonal does the sound feel? | Is a turbine tone audible at the reference position, wind bin by wind bin? |
| Input | One FFT spectrum, no calibration needed | Narrow-band spectra with the line spacing declared | The calibrated pressure signal, through the Sottek hearing model | Narrow-band spectra per wind-speed bin, with the reference distance |
| Output | A ratio in dB against a frequency-dependent criterion, plus a prominent / not prominent verdict | An audibility in dB, whose decisive and mean values feed the tonal adjustment `Kt` | A tonality in `tu_HMS`, a perceptual magnitude with no criterion | An audibility in dB per bin, reported with the turbine's sound power |
| Use it for | Declaring ITT equipment emission (ECMA-74 Annex D) | Environmental-noise rating: justifying, or refusing, a tonal penalty | Sound-quality work: comparing designs, not passing a limit | Type testing and acceptance of wind turbines |

Read the table as a decision: the *purpose of the report* picks the metric,
not the convenience of the input. A device emission declaration is an
ECMA-418-1 prominence verdict; a complaint about a tone from an installation
is an ISO 1996-2 rating, so it needs the audibility $\Delta L$ that maps to `Kt`
(the [tone-audibility guide](https://docs.jmrp.io/phonometry/perception/psychoacoustics/tone-audibility/));
a product comparison where nobody is being fined is where the ECMA-418-2
tonality earns its place, because it is a magnitude rather than a threshold
test (the [sound-quality guide](https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/)); and a
turbine is its own regime, with a measurement procedure in IEC 61400-11 that
fixes the geometry and the wind bins (the
[wind-turbine guide](https://docs.jmrp.io/phonometry/environment/sources/wind-turbine-noise/)).

Two consequences worth keeping in mind. First, the numbers do not convert:
a TNR of 12 dB is not an audibility of 12 dB, because the masking model, the
band definition and the reference differ. Second, the metrics can disagree
about the same sound, and legitimately so. A tone can be prominent by
ECMA-418-1 in the near field of the machine and inaudible at the dwelling
where the ISO 1996-2 assessment is made, while a hearing-model tonality
stays moderate throughout because it rates the whole sound and not one
spectral line. Report the metric the assessment calls for, and quote any
other only as supporting evidence.

## What this guide covers

- **Covered.** ECMA-418-1:2024 (3rd edition): the tone-to-noise ratio (clause 11, Formulae 9
  to 12) and prominence ratio (clause 12, Formulae 23 to 26) methods on
  Hann-windowed, RMS-averaged spectra, the clause 10 critical-band model, the
  frequency-dependent prominence criteria, and the clause 11.6 combination of
  secondary tones sharing a band, all through `tone_to_noise_ratio()` and
  `prominence_ratio()`. The clause 6 microphone positions and clause 7
  instrumentation requirements are documented in §2 as the conditions the two
  ratios are defined under.

- **Not covered.** The `prominent` verdict these functions return is the numeric criterion only.
  The standard also requires a prominent tone to be confirmed by aural
  examination (clauses 11.8/12.8) and to pass the clause 8/9
  lower-threshold-of-hearing screen, which needs calibrated absolute levels:
  both checks are left to the caller. ECMA-74:2025 is covered only as the
  standard that delegates its tone assessments to ECMA-418-1; its own Annex D
  measurement procedure and operator/bystander positions (shown above for
  context) are not implemented here.

## See also

- [Environmental Levels](https://docs.jmrp.io/phonometry/environment/assessment/environmental-levels/): the ISO 1996-1 rating levels and their Table A.1
  tonal adjustments, whose Kt is justified by the ISO/PAS 20065 audibility
  route; these prominence verdicts are complementary emission screening.
- [Sound Quality Metrics](https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/): the ECMA-418-2 psychoacoustic
  tonality T in tu_HMS, the hearing-model counterpart of these FFT ratios.
- [Objective audibility of tones in noise](https://docs.jmrp.io/phonometry/perception/psychoacoustics/tone-audibility/): the
  ISO/PAS 20065 audibility ΔL that the ISO 1996-2 tonal adjustment Kt is read from.
- [Wind-turbine noise](https://docs.jmrp.io/phonometry/environment/sources/wind-turbine-noise/): the IEC 61400-11 tonal
  audibility, the same question asked per wind-speed bin.
- [Impulsive-sound prominence](https://docs.jmrp.io/phonometry/environment/assessment/impulsive-sound/): the NT ACOU 112
  counterpart for impulsive (rather than tonal) character.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/perception/): the critical-band model and criteria derivation.
- API reference: [`psychoacoustics.quality.tonality`](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/tonality/).
- Theory: [Tone prominence: TNR and PR](https://docs.jmrp.io/phonometry/reference/theory/perception/#tone-prominence-tnr-and-pr-ecma-418-1): the critical-band construction behind TNR and PR, and the criteria that make a tone prominent.

## References

- **Ecma International. (2024).** [*Psychoacoustic metrics for ITT equipment — Part 1: Prominent discrete tones*](https://ecma-international.org/wp-content/uploads/ECMA-418-1_3rd_edition_december_2024.pdf) (ECMA-418-1:2024 (3rd ed.)).
  The implemented standard, freely downloadable (the linked PDF is the free download): the tone-to-noise ratio (clause 11) and prominence ratio (clause 12) methods, the critical-band model and the frequency-dependent prominence criteria of section 1.
- **Ecma International. (2025).** [*Measurement of airborne noise emitted by information technology and telecommunications equipment*](https://ecma-international.org/wp-content/uploads/ECMA-74_22nd_edition_december_2025.pdf) (ECMA-74:2025 (22nd ed.)).