# Sound Quality Metrics

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/perception/psychoacoustics/sound-quality/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-15
Updated: 2026-11-16T21:36:12Z
Standards: DIN 45692:2009-08; ECMA-418-2:2025
Verified: 10 conformance checks (DIN 45692:2009-08; ECMA-418-2:2025) https://docs.jmrp.io/phonometry/reference/conformance/#psychoacoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Sharpness in acum (DIN 45692) and the ECMA-418-2 Sottek Hearing Model tonality (tu_HMS), roughness (asper) and fluctuation strength (vacil_HMS).

---

Two sounds of equal loudness can still differ in how *sharp*, how *tonal*,
how *rough* or how strongly *fluctuating* they are. This page covers the
sound-quality metrics that complement loudness: sharpness (DIN 45692) and the
ECMA-418-2 tonality, roughness and fluctuation strength of the Sottek Hearing
Model. Loudness itself lives in [Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/loudness/);
the ECMA-418-2 loudness that shares the same auditory front-end lives in
[Advanced Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/advanced-loudness/).

The four metrics form one family: a single calibrated signal splits across
two auditory front ends, and every branch is anchored to a reference sound
whose normative target is exactly 1. The diagram maps the family with the
values the library actually computes for each reference (rounded results
such as 0.9999 asper and 0.9957 vacil_HMS sit against that target of 1).

![Block diagram of the sound-quality metric family: a calibrated signal in pascals feeds two auditory front ends, the Zwicker specific loudness pattern over 24 Bark and the ECMA-418-2 Sottek Hearing Model with 53 auditory bands; the first drives the DIN 45692 sharpness whose critical-band-wide noise reference at 1 kHz and 60 dB reads 1.00 acum, the second drives the tonality, roughness and fluctuation strength, whose references, a 1 kHz tone at 40 dB and 1 kHz carriers fully amplitude-modulated at 70 Hz and 4 Hz at 60 dB, read 1.000 tu_HMS, 0.9999 asper and 0.9957 vacil_HMS; a closing note states that N5, sharpness, roughness and fluctuation strength feed the Fastl and Zwicker psychoacoustic annoyance](https://docs.jmrp.io/phonometry/media/diagram_sound_quality.svg)

## Recording the signal these metrics need

ECMA-418-2 is a calculation applied to a recording, and clause 2 makes the
recording part of conformance: measurements conform only if they are taken in
conformity with ECMA-74 and carried out at 48 kHz, or resampled to it. That
pulls in a test environment qualified to ISO 11201 accuracy grade 2, a declared
operating mode, and the microphone at the ECMA-74 positions (the operator
position 0.25 m from the reference box at 1.20 m seated or 1.50 m standing, or
at least four bystander positions 1.00 m out and 1.50 m up) with the
background noise measured with the equipment off and a calibrator applied
before and after. The positions are the same ones the
[tone-prominence guide](https://docs.jmrp.io/phonometry/perception/psychoacoustics/tone-prominence/)
works from, and it states them in full:

![ECMA-74 emission measurement positions: seated operator microphone at 0.25 m and 1.20 m, and the four bystander positions at 1 m](https://docs.jmrp.io/phonometry/media/diagram_tonality_positions.svg)

**How long the record has to be** is the question the three ECMA metrics answer
differently, and no snippet on this page would tell you: the measurement
interval must cover at least three operational cycles, or the complete sequence
for equipment that varies, and on top of that each metric has a settling time
of its own. Tonality settles within about a second for a steady tone, because
the autocorrelation works inside each block. Roughness needs a couple of
seconds: its single value is the 90th percentile of $R(l_{50})$ over the blocks
that survive the initial transient, and the trace drawn further down takes
about 0.5 s to reach its plateau. Fluctuation strength needs the longest
record, of the order of ten seconds, because it resolves modulation rates near
4 Hz. Its trace is still climbing at 3 s and only settles around 4 s, so a
two-second excerpt contains a handful of modulation periods and reads low.

Draw the consequence: values computed on short clips are biased low for $R$ and
$F$, so compare only values computed over comparable durations, and state the
analysis length beside the value as a matter of course. The snippets below use
1.2 s, 2.0 s and 8.0 s for exactly this reason.

**Caution**

A binaural or artificial-head recording must already be free-field or
diffuse-field equalized before it reaches `tonality_ecma`, `roughness_ecma` or
`fluctuation_strength_ecma`. Clause 5.1.3 assumes it: in an ideal field the two
equalized channels correspond to a microphone at the centre of the now absent
artificial head, which is what the `field=` filter is built for. Feeding an
unequalized manikin recording applies the outer-ear filter twice. Each channel
is analysed separately, since the binaural combinations are not implemented.

## Sharpness in acum (DIN 45692)

Two sounds can be equally loud yet one feels "sharper" (hissy, metallic)
because its loudness sits higher on the Bark scale. Sharpness is the
$g(z)$-weighted first moment of the specific loudness pattern:

$$
S = k\,\frac{\int_0^{24} N'(z)\, g(z)\, z\ dz}{\int_0^{24} N'(z)\ dz}\ \text{acum}
$$

with $g(z) = 1$ up to 15.8 Bark and rising exponentially beyond, and $k$
normalized so the reference sound (critical-band-wide noise at 1 kHz,
60 dB) is exactly **1.00 acum** (DIN 45692 clause 6; the derived
$k = 0.108$ sits inside the normative window 0.105–0.115).

![DIN 45692 sharpness weighting g(z) against critical-band rate on a log axis, comparing the DIN, von Bismarck and Aures curves with the 15.8 and 15 Bark knees marked](https://docs.jmrp.io/phonometry/media/sharpness_weighting.svg)

*The three weightings. All are flat to about 15 Bark and rise exponentially
above it, which is what makes high-frequency loudness count for more; the
Aures curve, unlike the other two, moves with the total loudness.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# DIN 45692 sharpness weighting g(z): Eq. (1) plus the informative Annex B variants
z = np.arange(1, 241) * 0.1                     # Bark bins, 0.1 .. 24.0
g_din = np.where(z > 15.8, 0.15 * np.exp(0.42 * (z - 15.8)) + 0.85, 1.0)
g_bis = np.where(z > 15.0, 0.2 * np.exp(0.308 * (z - 15.0)) + 0.8, 1.0)
n = 4.0                                         # Aures depends on the total loudness (sone)
g_aures = 0.078 * np.exp(0.171 * z) / z * (n / np.log(n * 0.05 + 1.0))

fig, ax = plt.subplots()
ax.semilogy(z, g_din, label="DIN 45692 g(z)")
ax.semilogy(z, g_bis, "--", label="von Bismarck (Annex B)")
ax.semilogy(z, g_aures, "-.", label="Aures (Annex B, N = 4 sone)")
ax.axvline(15.8, linestyle=":", color="0.5")    # DIN knee: g rises beyond 15.8 Bark
ax.set(xlabel="Critical-band rate z [Bark]", ylabel="Weighting g(z)")
ax.grid(True, which="both", alpha=0.3)
ax.legend()
plt.show()
```

```python
import numpy as np
from phonometry import psychoacoustics

# A raw recording plus its calibration so the guide runs standalone
fs = 48000
x = 0.2 * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs)   # any recording (digital units)
sens = 1.0                                                # calibration_factor to pascals

s = psychoacoustics.sharpness_din(x, fs, calibration_factor=sens)      # acum
s_aures = psychoacoustics.sharpness_din(x, fs, method="aures")        # Annex B variant
print(f"S = {s:.2f} acum  (Aures {s_aures:.2f} acum)")                # 1.03 acum (Aures 1.23)
```

CI verifies the Table A.2 target values (0.38 acum at 250 Hz up to
2.82 acum at 4 kHz) within the standard's 5 % / 0.05 acum tolerance.

**Sharpness is a position, not a level.** Both the numerator and the
denominator of $S$ contain $N'(z)$, so the level cancels: what the ratio
answers is *where on the Bark axis this sound's loudness sits*. That is why
DIN 45692 clause 6 fixes the reference sound and every one of its verification
signals at the same loudness, 4 sone, and why comparing the sharpness of two
sounds of very different loudness is close to meaningless. The range is worth
memorising: a critical band of noise at 250 Hz reads about 0.4 acum, the 1 kHz
reference exactly 1 acum, a critical band at 4 kHz about 2.8 acum, and
broadband product noise usually lands between 1 and 3 acum, with the
hiss-dominated sounds customers call shrill above 2 acum.

![Left: two Zwicker specific-loudness patterns of equal total loudness, a 250 Hz critical band of noise centred at 3.4 Bark reading 0.37 acum and a 4 kHz critical band centred at 18.1 Bark reading 2.75 acum. Right: the DIN 45692 Table A.2 verification sweep from 250 Hz to 4 kHz, the computed sharpness curve running through the tabulated hearing-test targets inside a shaded band of 5 percent or 0.05 acum](https://docs.jmrp.io/phonometry/media/sharpness_pair_and_targets.svg)

*Equal loudness, seven times the sharpness. Both patterns integrate to 4 sone;
what differs is where they sit, and that is the whole content of the metric.
Right: the same computation against the standard's own hearing-test targets,
every point inside the permitted deviation.*

**Show the code for this figure**

```python
import numpy as np
from scipy import signal as sp_signal

# `psychoacoustics` is imported by the snippets above.
# One DIN 45692 Table A.1 critical band of noise, at a chosen band level.
def critical_band_noise(f_low, f_high, level):
    rng = np.random.default_rng(7)
    sos = sp_signal.butter(8, [f_low, f_high], btype="band", fs=48000, output="sos")
    band = sp_signal.sosfilt(sos, rng.standard_normal(48000 * 2))
    band /= np.sqrt(np.mean(band**2))
    return band * 2e-5 * 10 ** (level / 20)

# Table A.2 compares signals of equal loudness, so set each band to 4 sone.
def level_for_four_sone(f_low, f_high):
    low, high = 30.0, 95.0
    for _ in range(14):
        mid = (low + high) / 2
        loud = psychoacoustics.loudness_zwicker(
            critical_band_noise(f_low, f_high, mid), 48000, stationary=True).loudness
        low, high = (mid, high) if loud < 4.0 else (low, mid)
    return (low + high) / 2

for centre, f_low, f_high, target in [(250.0, 200.0, 300.0, 0.38),
                                      (4000.0, 3700.0, 4400.0, 2.82)]:
    band = critical_band_noise(f_low, f_high, level_for_four_sone(f_low, f_high))
    print(centre, round(float(psychoacoustics.sharpness_din(band, 48000)), 2), target)
#   250.0 0.37 0.38
#   4000.0 2.75 2.82
```

**Which variant.** The DIN weighting is loudness-independent, a good
approximation near the 4 sone it was calibrated at but under-reading the
sharpness listeners report for very quiet sounds; the informative Aures
weighting scales with the total loudness and is therefore the variant to reach
for when the sounds being compared differ markedly in loudness. Von Bismarck is
the historical curve with its knee at 15 Bark, kept for continuity with older
data. For a sound whose spectrum moves, DIN 45692 clause 6 recommends quoting
the percentile $S_{50}$ over the analysis rather than one instantaneous value.

### `sharpness_din()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D array | Pa (after calibration) | non-empty | The signal the specific-loudness pattern is computed from |
| `fs` | int | Hz | > 0 | |
| `field` | str | — | `'free'` (default) / `'diffuse'` | The ISO 532-1 sound-field correction, inherited from the loudness stage |
| `method` | str | — | `'din'` (default, clause 6) / `'bismarck'` / `'aures'` | The $g(z)$ weighting; the last two are Annex B |
| `calibration_factor` | float | Pa per digital unit | default `1.0` | From `sensitivity()` |

Unlike the three ECMA metrics below, `sharpness_din()` returns a plain float in
acum, not a result object with its own `.plot()`.

## Tonality (ECMA-418-2)

A tonal component (a whistle, a fan's blade-passing tone) stands out even at
low level. ECMA-418-2 quantifies it from the **autocorrelation function** (ACF)
of each band's rectified signal: a periodic (tonal) component keeps a high ACF
at nonzero lag, and the tonal-to-noise loudness ratio drives the specific
tonality $T'(z)$. The single value $T$ is in **tu_HMS**, calibrated so a
1 kHz/40 dB tone is $\approx 1$ tu_HMS; the result also tracks the tonal
frequency $f_\text{ton}$ per band.

```python
import numpy as np
from phonometry import psychoacoustics

fs = 48000
t = np.arange(int(1.2 * fs)) / fs
x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * t)

res = psychoacoustics.tonality_ecma(x, fs, field="free")
peak = int(np.argmax(res.specific_tonality))
print(f"T = {res.tonality:.3f} tu_HMS")                    # 1.000 tu_HMS
print(f"f_ton = {res.tonal_frequencies[peak]:.0f} Hz")     # 999 Hz

# Clause 6.3 for a stationary sound: T'(z) above 0.4 tu_HMS at a local maximum
# (the peak is one), with f_ton between F(z - 1) and F(z + 1), where F is the
# centre frequency of Formula 9 at a critical-band rate z in Bark_HMS; it is
# defined for any z, so the test holds at the first and last bands too.
def centre_frequency(z):
    return 81.9289 / 0.1618 * np.sinh(0.1618 * z)   # Formula 9, F(z) in Hz

z = res.bark[peak]
prominent = (
    res.specific_tonality[peak] > psychoacoustics.PROMINENT_TONALITY_TU_HMS
    and centre_frequency(z - 1) <= res.tonal_frequencies[peak] <= centre_frequency(z + 1)
)
print(prominent)   # True: a prominent tonal component (clause 6.3)

res.plot()   # average specific tonality T'(z) + time-dependent T(l)
```

![ECMA-418-2 average specific tonality over the 53 Bark_HMS bands for a 1 kHz tone at 40 dB SPL: the tonality is concentrated in a single peak at the tone's critical band around 9 Bark_HMS and falls to nearly zero elsewhere, integrating to T = 1.00 tu_HMS](https://docs.jmrp.io/phonometry/media/sottek_specific_tonality.svg)

*The calibration anchor seen band by band: a 1 kHz tone at 40 dB puts all of
its tonality in one critical band, which is what makes the tonal-to-noise
loudness ratio large there and negligible everywhere else.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

# The calibration anchor: a 1 kHz tone at 40 dB SPL is about 1 tu_HMS.
fs = 48000
t = np.arange(int(1.2 * fs)) / fs
x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * t)
res = psychoacoustics.tonality_ecma(x, fs, field="free")

# One line: passing an axes draws the specific-tonality panel alone.
fig, ax = plt.subplots()
res.plot(ax=ax)
plt.show()

# Or draw T'(z) by hand against the critical-band-rate scale:
fig, ax = plt.subplots()
ax.fill_between(res.bark, res.specific_tonality, alpha=0.3, color="#d62728")
ax.plot(res.bark, res.specific_tonality, color="#d62728")
ax.set_xlabel(r"Critical-band rate $z$ [$\mathrm{Bark}_\mathrm{HMS}$]")
ax.set_ylabel(r"Specific tonality $T'$ [$\mathrm{tu}_\mathrm{HMS}$]")
plt.show()
```

The concentration is what distinguishes a tonal sound from a broadband one of
the same loudness: the autocorrelation stage finds a periodic component in one
band and almost nothing in the others. A fan with a blade-passing tone and a
harmonic series shows several such peaks; a hiss shows a flat, low pattern.
Calling `.plot()` without an axes adds the time-dependent $T(l)$ panel, which
is where an intermittent tone shows up.

**Reading a tonality.** ECMA-418-2 clause 6.3 gives two prominence criteria,
both at the 0.4 tu_HMS that `psychoacoustics.PROMINENT_TONALITY_TU_HMS` holds,
and `tonality_ecma()` applies neither: it returns the values they are read
from. For a stationary sound, a tonal component in band
$z_\text{tonal}$ counts as prominent when the specific tonality
$T'(z_\text{tonal})$ exceeds 0.4 tu_HMS, is a local maximum along $z$, and
carries a tonal frequency between the centre frequencies $F(z_\text{tonal} - 1)$
and $F(z_\text{tonal} + 1)$; that statement is read from `specific_tonality` and
`tonal_frequencies`. For a non-stationary sound, the signal contains prominent
tonalities when the single value $T$ of Formula (63) exceeds 0.4 tu_HMS. The
test for one discrete tone against the noise around it is the ECMA-418-1
tone-to-noise and prominence ratio of
[Prominent Discrete Tones](https://docs.jmrp.io/phonometry/perception/psychoacoustics/tone-prominence/).

**Is the sound audible?** The fourth criterion of ECMA-418-2, the 0.01 sone_HMS
of clause 5.1.9 that `psychoacoustics.AUDIBILITY_THRESHOLD_SONE_HMS` holds,
reads none of the three metrics of this guide: it reads the total basis
loudness of Formula 26, the specific basis loudness summed over the 53 bands,
which `loudness_ecma()` returns block by block as `basis_loudness_vs_time`,
segmented as clause 5.1.5.1 prescribes for tonality and loudness (the block
sizes of Table 4). Roughness and fluctuation strength form a specific basis
loudness of their own, with the fixed blocks of clause 5.1.5.2 and the start
padding of clause 5.1.2.2, which differs from this one for a sound that
changes in time; clause 5.1.9 names no segmentation, so reading the criterion
on the one the loudness of Clause 8 is built on is the library's choice.
[Advanced Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/advanced-loudness/)
shows how the total is formed and why the comparison stops at
`last_evaluated_block`. No function applies the criterion. Clause 6.1.1 adds
that the tonality method needs no audibility screening before it, because
the threshold of hearing is built into the model; the comparison answers
whether the sound is heard at all.

```python
# `x` is the 1 kHz tone at 40 dB SPL of the tonality snippet above.
loud = psychoacoustics.loudness_ecma(x, fs, field="free")
n_basis = loud.basis_loudness_vs_time[: loud.last_evaluated_block + 1]
print((n_basis > psychoacoustics.AUDIBILITY_THRESHOLD_SONE_HMS).any())   # True: above it in a block
```

### `tonality_ecma()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D array | Pa | non-empty | Calibrated pressure signal |
| `fs` | float | Hz | > 0 | Resampled to 48 kHz internally if needed |
| `field` | str | — | `'free'` (default) / `'diffuse'` | Outer/middle-ear filter |
| `f_low` | float, optional | Hz | default `None` | Lower edge of a user band for the $T(l)$ search |
| `f_high` | float, optional | Hz | default `None` | Upper edge of the user band |

Returns an `EcmaTonality`: `tonality` ($T$, tu_HMS), `specific_tonality`
($T'(z)$, 53 bands), `bark`, `frequencies`, `tonal_frequencies`
($f_{\text{ton},z}$), `times`, `tonality_vs_time` ($T(l)$),
`tonal_frequency_vs_time`,
`field`.

## Roughness in asper (ECMA-418-2)

Roughness is the harsh, buzzing sensation of fast amplitude modulation
(roughly 20–300 Hz, peaking near 70 Hz): the quality of a diesel idle or a
distorted loudspeaker. ECMA-418-2
extracts each band's envelope, weights its modulation spectrum by modulation
rate and depth, and correlates the modulation across bands; the result $R$ is
in **asper**. The reference sound (1 kHz carrier, 100 % amplitude-modulated at
70 Hz, overall level 60 dB SPL) is defined as 1 asper; this clean-room
implementation returns 0.9999 asper with the tabulated calibration constant
$c_\mathrm{R}$ (Formula 104) used **without** reverse-fitting to the target.

```python
import numpy as np
from phonometry import psychoacoustics

fs = 48000
t = np.arange(int(2.0 * fs)) / fs
x = (1.0 + np.cos(2 * np.pi * 70 * t)) * np.sin(2 * np.pi * 1000 * t)
x *= 2e-5 * 10 ** (60 / 20) / np.sqrt(np.mean(x**2))   # overall 60 dB SPL

res = psychoacoustics.roughness_ecma(x, fs, field="free")
print(f"R = {res.roughness:.4f} asper")   # 0.9999 asper (reference: 1 asper)
print(res.roughness > psychoacoustics.PROMINENT_ROUGHNESS_ASPER)   # True: prominent (clause 7.2)

res.plot()   # time-dependent roughness R(l50) + specific-roughness heatmap
```

![Two panels. Top: the ECMA-418-2 time-dependent tonality T(t) over two seconds for a 1 kHz tone in noise, holding near 1.19 tu_HMS, against pure noise flat at 0.02 tu_HMS. Bottom: the roughness of a 1 kHz carrier at 100 percent amplitude modulation against modulation frequency from 10 to 210 Hz, rising to a marked peak of 1.0 asper at 70 Hz and falling away on either side](https://docs.jmrp.io/phonometry/media/tonality_roughness_demo.svg)

*The two sensations, each read the way its clause defines it: tonality as a
time trace, which separates a tone in noise from the noise alone, and roughness
as a function of modulation rate, whose 70 Hz peak on a fully modulated 1 kHz
carrier at 60 dB is the calibration point of the asper.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

fs, p0 = 48000, 2e-5

# Top panel: tonality T(t) of a 1 kHz tone in noise against the noise alone,
# each component at 50 dB SPL over 2 s.
t = np.arange(int(2.0 * fs)) / fs
rng = np.random.default_rng(2026)
noise = rng.standard_normal(t.size)
noise *= p0 * 10 ** (50 / 20) / np.sqrt(np.mean(noise**2))
tone = p0 * 10 ** (50 / 20) * np.sqrt(2) * np.sin(2 * np.pi * 1000 * t)
tin = psychoacoustics.tonality_ecma(tone + noise, fs)
pn = psychoacoustics.tonality_ecma(noise, fs)

# Bottom panel: roughness of a 1 kHz carrier at 100 % AM, swept over the
# modulation frequency (1 s per point at 60 dB SPL).
tm = np.arange(fs) / fs
fmods = np.array([20.0, 30, 40, 50, 60, 70, 80, 100, 120, 150, 180, 200])
r = []
for fm in fmods:
    am = (1 + np.sin(2 * np.pi * fm * tm)) * np.sin(2 * np.pi * 1000 * tm)
    am *= p0 * 10 ** (60 / 20) / np.sqrt(np.mean(am**2))
    r.append(psychoacoustics.roughness_ecma(am, fs).roughness)

fig, (ax0, ax1) = plt.subplots(2, 1, figsize=(10, 8.5))
ax0.plot(tin.times, tin.tonality_vs_time,
         label=rf"Tone in noise ($T$ = {tin.tonality:.2f} $\mathrm{{tu}}_\mathrm{{HMS}}$)")   # 1.19
ax0.plot(pn.times, pn.tonality_vs_time,
         label=rf"Pure noise ($T$ = {pn.tonality:.2f} $\mathrm{{tu}}_\mathrm{{HMS}}$)")       # 0.02
ax0.set(xlabel="Time [s]", ylabel=r"Tonality $T$ [$\mathrm{tu}_\mathrm{HMS}$]")
ax0.legend()
ax1.plot(fmods, r, "o-", label="1 kHz carrier, 100 % AM")          # peak 1.0 asper
ax1.set(xlabel=r"Modulation frequency $f_\mathrm{mod}$ [Hz]", ylabel="Roughness $R$ [asper]")
ax1.legend()
plt.show()
```

**Reading a roughness.** Clause 7.2 gives a single criterion: a signal has
*prominent* roughness when the single value $R$, the 90th percentile of the
time-dependent $R(l_{50})$, not its mean, exceeds 0.2 asper, the
`psychoacoustics.PROMINENT_ROUGHNESS_ASPER` the snippet above compares it
with; no function applies it. The percentile matters: short bursts of
harshness are not averaged away, which also means the record has to be long
enough for that percentile to settle. The figure below is the reference sound
seen the two ways the result object carries it.

![Left: the ECMA-418-2 average specific roughness of the reference sound over the 53 Bark_HMS bands, a single peak of 0.37 asper per Bark_HMS at the carrier's band at 9 Bark_HMS. Right: the time-dependent roughness of the same signal rising from zero and reaching its plateau after about half a second, with the 90th percentile of 0.9999 asper drawn across it](https://docs.jmrp.io/phonometry/media/sottek_specific_roughness.svg)

*The reference sound, band by band and instant by instant. The single value is
the dashed line: a percentile of the trace on the right, integrated from the
pattern on the left. The half-second run-up is why a two-second record is the
practical minimum.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# `res` is the roughness result of the snippet above.
fig, (ax0, ax1) = plt.subplots(1, 2, figsize=(12, 4.8))
ax0.plot(res.bark, res.specific_roughness)
ax0.set(xlabel=r"Critical-band rate $z$ [$\mathrm{Bark}_\mathrm{HMS}$]",
        ylabel=r"Specific roughness $R'(z)$ [$\mathrm{asper}/\mathrm{Bark}_\mathrm{HMS}$]")
ax1.plot(res.times, res.roughness_vs_time)
ax1.axhline(res.roughness, linestyle="--")     # the 90th percentile
ax1.set(xlabel="Time [s]", ylabel="Roughness R [asper]")
plt.show()
```

### `roughness_ecma()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D array | Pa | non-empty | Calibrated pressure signal |
| `fs` | float | Hz | > 0 | Resampled to 48 kHz internally if needed |
| `field` | str | — | `'free'` (default) / `'diffuse'` | Outer/middle-ear filter |

Returns an `EcmaRoughness`: `roughness` ($R$, asper, the 90th percentile of
$R(l_{50})$), `specific_roughness` ($R'(z)$, 53 bands), `bark`,
`frequencies`, `times`, `roughness_vs_time` ($R(l_{50})$),
`specific_roughness_vs_time` ((n_times, 53) array), `field`.

## Fluctuation strength in vacil_HMS (ECMA-418-2)

Fluctuation strength is the slow, wobbling sensation of amplitude or
frequency modulation below about 20 Hz: a siren, beating tones, speech at
syllable rate. It is the slow counterpart of roughness: the same hearing
model splits envelope modulation into a slow band-pass peaking near 4 Hz
(fluctuation strength, in **vacil_HMS**) and a fast one peaking near 70 Hz
(roughness). ECMA-418-2 Clause 9 analyses each band's envelope with
High-resolution Spectral Analysis (HSA), a least-squares fit of
window-kernel spectral line pairs that resolves modulation rates far below
the DFT bin width, using envelope-dependent analysis windows that skip
quieter periods, then weights the dominant harmonic complex and scales it
with an HSA-based specific loudness. The reference sound (1 kHz carrier,
100 % amplitude-modulated at 4 Hz, overall level 60 dB SPL) is defined as
1 vacil_HMS; this clean-room implementation converges to 0.9958 vacil_HMS
by 12 s with the tabulated calibration constant $c_\mathrm{F}$ (Formula 163) used
**without** reverse-fitting to the target (the 8 s example below prints
0.9957). A signal whose single value $F$ exceeds 0.2 vacil_HMS,
`psychoacoustics.PROMINENT_FLUCTUATION_STRENGTH_VACIL_HMS`, has a *prominent*
fluctuation strength (Clause 9.2); no function applies the criterion, and it
holds for this metric only, not for the Osses `fluctuation_strength()` in
plain vacil.

```python
import numpy as np
from phonometry import psychoacoustics

fs = 48000
t = np.arange(int(8.0 * fs)) / fs
x = (1.0 + np.cos(2 * np.pi * 4 * t)) * np.sin(2 * np.pi * 1000 * t)
x *= 2e-5 * 10 ** (60 / 20) / np.sqrt(np.mean(x**2))   # overall 60 dB SPL

res = psychoacoustics.fluctuation_strength_ecma(x, fs, field="free")
print(f"F = {res.fluctuation_strength:.4f} vacil_HMS")   # 0.9957 vacil_HMS (reference: 1 vacil_HMS)
print(res.fluctuation_strength > psychoacoustics.PROMINENT_FLUCTUATION_STRENGTH_VACIL_HMS)   # True: prominent (clause 9.2)

res.plot()   # time-dependent F(l50) + specific-fluctuation-strength heatmap
```

![ECMA-418-2 slow vs fast modulation perception: fluctuation strength forms a band-pass over modulation frequency peaking near 4 to 6 Hz while roughness of the same 1 kHz amplitude-modulated tones peaks near 70 Hz](https://docs.jmrp.io/phonometry/media/hms_modulation_bandpass.svg)

*Two band-passes on the same envelope. The same modulated carrier is heard as
fluctuation below about 20 Hz and as roughness above it, which is why the two
metrics divide the modulation axis between them rather than competing on it.*

![Left: the ECMA-418-2 average specific fluctuation strength of the reference sound over the 53 Bark_HMS bands, a single peak of 0.38 vacil_HMS per Bark_HMS at the carrier's band at 9 Bark_HMS. Right: the time-dependent fluctuation strength of the same signal climbing for about four seconds before settling, with the 90th percentile of 0.9957 vacil_HMS drawn across it](https://docs.jmrp.io/phonometry/media/sottek_specific_fluctuation.svg)

*The same two views for the slow sensation, and the reason this metric needs
the longest record on the page: the trace is still climbing at 3 s. A
two-second excerpt of this very reference sound would read well below
1 vacil_HMS.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

fs = 48000
t = np.arange(int(3.0 * fs)) / fs
carrier = np.sin(2 * np.pi * 1000 * t)

def am_tone(fmod):
    # 100 % AM at an overall level of 60 dB SPL (the Clause 7/9 convention)
    x = (1.0 + np.sin(2 * np.pi * fmod * t)) * carrier
    return x * 2e-5 * 10 ** (60 / 20) / np.sqrt(np.mean(x**2))

fm_slow = [0.5, 1, 2, 4, 8, 16, 32]
fm_fast = [20, 40, 70, 100, 150, 200]
f_vals = [psychoacoustics.fluctuation_strength_ecma(am_tone(fm), fs).fluctuation_strength
          for fm in fm_slow]
r_vals = [psychoacoustics.roughness_ecma(am_tone(fm), fs).roughness for fm in fm_fast]

fig, ax = plt.subplots()
ax.semilogx(fm_slow, f_vals, "o-", label=r"Fluctuation strength $F$ [$\mathrm{vacil}_\mathrm{HMS}$]")
ax.semilogx(fm_fast, r_vals, "s-", label="Roughness R [asper]")
ax.set(xlabel="Modulation frequency [Hz]", ylabel=r"$F$ [$\mathrm{vacil}_\mathrm{HMS}$] / $R$ [asper]")
ax.legend()
plt.show()
```

### `fluctuation_strength_ecma()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D array | Pa | non-empty | Calibrated pressure signal |
| `fs` | float | Hz | > 0 | Resampled to 48 kHz internally if needed |
| `field` | str | — | `'free'` (default) / `'diffuse'` | Outer/middle-ear filter |

Returns an `EcmaFluctuationStrength`: `fluctuation_strength` ($F$, vacil_HMS,
the 90th percentile of $F(l_{50})$), `specific_fluctuation_strength`
($F'(z)$, 53 bands), `bark`, `frequencies`, `times`,
`fluctuation_strength_vs_time` ($F(l_{50})$),
`specific_fluctuation_strength_vs_time` ((n_times, 53) array), `field`.

The Fastl & Zwicker fluctuation-strength models (closed form for AM
broadband noise and the Osses 2016 signal model) live in
[Psychoacoustic Annoyance](https://docs.jmrp.io/phonometry/perception/psychoacoustics/psychoacoustic-annoyance/);
this Clause 9 metric is the normative Sottek-model counterpart.

See [Prominent Discrete Tones](https://docs.jmrp.io/phonometry/perception/psychoacoustics/tone-prominence/) for the
ECMA-418-1 TNR/PR prominence verdicts,
[Speech Transmission Index](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/) for
STI/STIPA, and [Theory](https://docs.jmrp.io/phonometry/reference/theory/perception/) for the underlying math.

## What this guide covers

- **Covered.** DIN 45692:2009-08 through `sharpness_din()`: the clause 6 weighting over the ISO
  532-1 specific-loudness pattern, plus the informative Annex B von Bismarck and
  Aures variants, with the Table A.2 targets checked in CI. ECMA-418-2:2025 on
  the shared clause 5 auditory front-end: the clause 6.2 tonality output stages
  (`tonality_ecma()`), the clause 7 roughness chain (`roughness_ecma()`) and the
  clause 9 HSA fluctuation strength (`fluctuation_strength_ecma()`). Each uses
  the standard's tabulated calibration constant, not a reverse fit to the
  reference sound.

- **Not covered.** The three ECMA-418-2 entry points are monaural: the binaural quadratic-mean
  combinations of Formula 112 (clause 7.1.11) and Formula 170 (clause 9.1.15)
  are not implemented, so analyse each channel separately. The optional entropy
  weighting of clause 7.1.6 needs an external rotational-speed signal and is
  left out, as is the ±0.25 % adjustment of $c_\mathrm{F}$ that footnote 47 permits. The
  ECMA-418-2 loudness that shares this front-end lives in [Advanced
  Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/advanced-loudness/), and the
  Fastl and Zwicker fluctuation-strength models in [Psychoacoustic
  Annoyance](https://docs.jmrp.io/phonometry/perception/psychoacoustics/psychoacoustic-annoyance/).

## See also

- API reference: [`psychoacoustics.quality.sharpness`](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/sharpness/), [`psychoacoustics`: tonality (Sottek model)](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/tonality-ecma/), [`psychoacoustics`: roughness (Sottek model)](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/roughness-ecma/) and [`psychoacoustics`: fluctuation strength (Sottek model)](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/fluctuation-strength-ecma/).
- Theory: [Advanced loudness models and sound quality](https://docs.jmrp.io/phonometry/reference/theory/perception/#advanced-loudness-models--sound-quality): the specific-loudness pattern the sharpness, roughness and fluctuation-strength metrics are all built on.

## Quick answers

### Above what values does ECMA-418-2 call tonality, roughness or fluctuation strength prominent?

ECMA-418-2 sets one threshold per metric, and the library holds each as a
constant: `psychoacoustics.PROMINENT_TONALITY_TU_HMS` is `0.4` tu_HMS
(clause 6.3), `PROMINENT_ROUGHNESS_ASPER` is `0.2` asper (clause 7.2) and
`PROMINENT_FLUCTUATION_STRENGTH_VACIL_HMS` is `0.2` vacil_HMS (clause 9.2).
Roughness and fluctuation strength compare their single value $R$ or $F$ with
it. Tonality compares the specific tonality of a band that is a local maximum,
with its tonal frequency between $F(z - 1)$ and $F(z + 1)$, for a stationary
sound, and the
single value $T$ for one that varies in time.

```python
from phonometry import psychoacoustics

print(psychoacoustics.PROMINENT_TONALITY_TU_HMS)                 # 0.4 tu_HMS
print(psychoacoustics.PROMINENT_ROUGHNESS_ASPER)                 # 0.2 asper
print(psychoacoustics.PROMINENT_FLUCTUATION_STRENGTH_VACIL_HMS)  # 0.2 vacil_HMS
```

## References

- **Deutsches Institut für Normung. (2009).** [*Messtechnische Simulation der Hörempfindung Schärfe*](https://www.dinmedia.de/en/standard/din-45692/117635111) (DIN 45692:2009-08).
  Sharpness in acum: the clause 6 weighting, the Annex B von Bismarck and Aures variants and the Table A.2 targets.
- **Ecma International. (2025).** [*Psychoacoustic metrics for ITT equipment — Part 2 (methods for describing human perception based on the Sottek Hearing Model)*](https://ecma-international.org/publications-and-standards/standards/ecma-418/) (ECMA-418-2:2025).
  The Sottek Hearing Model tonality (tu_HMS, clause 6), roughness (asper, clause 7) and fluctuation strength (vacil_HMS, clause 9, the HSA-based envelope analysis).
- **Fastl, H., & Zwicker, E. (2007).** *Psychoacoustics: Facts and models* (3rd ed.). Springer. https://doi.org/10.1007/978-3-540-68888-4
  The psychoacoustics of the sensations quantified on this page: the high-frequency emphasis behind sharpness and the fast-modulation percept behind roughness.