# Advanced Loudness (ISO 532-2/-3, ECMA-418-2)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/perception/psychoacoustics/advanced-loudness/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/perception/psychoacoustics/advanced-loudness/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-29
Updated: 2026-11-16T21:36:10Z
Standards: ISO 532-2:2017; ISO 532-3:2023; ECMA-418-2:2025
Verified: 10 conformance checks (ISO 532-2:2017; ISO 532-3:2023; ECMA-418-2:2025) https://docs.jmrp.io/phonometry/reference/conformance/#psychoacoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: ERB_N and the Cam scale, Moore-Glasberg loudness (ISO 532-2), time-varying loudness (ISO 532-3), Sottek loudness (ECMA-418-2) and which model to choose.

---

The Zwicker method of ISO 532-1 is the reference route to loudness in sones
and lives in [Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/loudness/), together with the
ISO 226 equal-loudness contours. This page covers the newer model families
phonometry ships beside it: the **Moore-Glasberg** loudness of
ISO 532-2/532-3 and the **Sottek Hearing Model** loudness of
ECMA-418-2:2025, whose shared auditory front-end also powers the tonality
and roughness metrics of
[Sound Quality Metrics](https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/).

The page opens with the choice: which model fits which measurement, and why
the sone values of the four methods agree at the 1 kHz / 40 dB anchor yet
are not interchangeable digit for digit. Each model then gets its own
section with a worked example, its figure and its parameter table.

## Choosing a loudness model

| Model | Standard | Stationary / time-varying | Output | When to use |
| :--- | :--- | :--- | :--- | :--- |
| [Zwicker](https://docs.jmrp.io/phonometry/perception/psychoacoustics/loudness/) | ISO 532-1:2017 | both | sone | Reference method; one-third-octave input; fast and widely cited |
| Moore-Glasberg | ISO 532-2:2017 | stationary | sone | roex excitation pattern; better for tones and explicit binaural summation |
| Moore-Glasberg-Schlittenlacher | ISO 532-3:2023 | time-varying | sone (STL/LTL) | Time-varying loudness with short-/long-term traces and the peak $N_\text{max}$ |
| Sottek (Hearing Model) | ECMA-418-2:2025 | time-varying | sone_HMS | Shares one auditory front-end with the ECMA tonality and roughness metrics |

All four methods are anchored so a **1 kHz tone at 40 dB SPL is ≈ 1 sone**; the values
are not interchangeable digit-for-digit because the models differ in their
auditory filters and their loudness summation.

![Loudness of a 1 kHz tone as a function of level for the Zwicker, Moore-Glasberg and Sottek models, all passing close to 1 sone at 40 dB SPL](https://docs.jmrp.io/phonometry/media/loudness_models_comparison.svg)

*The three models pass through approximately 1 sone at the 40 dB anchor
(the Sottek front-end returns 0.9845 sone_HMS there) and diverge with level:
Zwicker doubles the sone value every +10 phon, while the Sottek model grows
more slowly (about 1.65× per 10 dB), an intrinsic difference between the
auditory summations, not a calibration error.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

# 1 kHz tone, 20..80 dB SPL: all three models pass close to 1 sone at 40 dB
fs = 48000
t = np.arange(fs) / fs
levels = np.arange(20.0, 81.0, 10.0)
zw, mg, ec = [], [], []
for spl in levels:
    x = np.sqrt(2) * 2e-5 * 10 ** (spl / 20) * np.sin(2 * np.pi * 1000 * t)
    zw.append(psychoacoustics.loudness_zwicker(x, fs, stationary=True).loudness)
    mg.append(
        psychoacoustics.loudness_moore_glasberg_from_spectrum([(1000.0, float(spl))]).loudness
    )
    ec.append(psychoacoustics.loudness_ecma(x, fs).loudness)

fig, ax = plt.subplots()
ax.plot(levels, zw, "o-", label="Zwicker (ISO 532-1)")
ax.plot(levels, mg, "s--", label="Moore-Glasberg (ISO 532-2)")
ax.plot(levels, ec, "^-.", label="Sottek (ECMA-418-2)")
ax.plot(40.0, 1.0, "o", color="k", markerfacecolor="none", markersize=10)   # the shared anchor
ax.set(xlabel="Sound pressure level [dB SPL]", ylabel="Total loudness N [sone]")
ax.legend()
plt.show()
```

## The ERB_N scale and the Cam axis

Every model on this page except Zwicker's is written on the **ERB_N
number** axis, so it is worth having the scale itself in hand. The cochlea
behaves as a bank of overlapping band-pass **auditory filters**; the width of
the one centred on a given frequency is summarised by its *equivalent
rectangular bandwidth*, the bandwidth of the rectangular filter that would pass
the same power with the same peak response. Fitting notched-noise data for
young listeners at moderate levels, Glasberg and Moore (1990) make it a
straight line in frequency (Moore, *An Introduction to the Psychology of
Hearing* 6e, p. 76):

$$
\mathrm{ERB}_N = 24.7\,(4.37\,F + 1)\ \text{Hz},\qquad F \text{ in kHz}.
$$

Integrating $df/\mathrm{ERB}_N(f)$ turns that into a frequency scale on which
one step is one auditory-filter width. The scale is the **ERB_N
number** and its unit is the **Cam**, after Cambridge:

$$
\mathrm{ERB}_N\ \text{number} = 21.4 \log_{10}(4.37\,F + 1)\ \text{Cam}.
$$

```python
from phonometry import psychoacoustics

cam = psychoacoustics.cam_from_frequency(1000.0)
print(round(psychoacoustics.erb_bandwidth(1000.0), 1))       # 132.4 Hz
print(round(cam, 2))                                         # 15.59 Cam
print(round(psychoacoustics.frequency_from_cam(cam), 1))     # 1000.0 Hz
```

The library states the same fit with one more significant digit,
$\mathrm{ERB}_N = 24.673\,(0.004368 f + 1)$ and
$21.366 \log_{10}(0.004368 f + 1)$, the precision the ISO 532-2 implementation
uses; the two forms agree to better than 0.2 % over the audible range, and the
extra digits are what make `frequency_from_cam` an exact inverse. These are not
private helpers of the loudness model: `loudness_moore_glasberg` calls the same
three functions, so a `MooreGlasbergLoudness.erb_number` grid and a Cam axis
you build yourself cannot drift apart.

![Auditory-filter bandwidth against centre frequency on log-log axes: the ERB_N line of Glasberg and Moore rising from about 30 Hz at 50 Hz to above 1 kHz at 16 kHz, the constant-percentage one-third-octave bandwidth crossing it near 500 Hz, the 1 kHz point annotated at 15.59 Cam, and a second top axis giving the Cam scale](https://docs.jmrp.io/phonometry/media/erb_bandwidth.svg)

*The ear's filter is not a constant fraction of frequency. Below about 500 Hz
it is markedly narrower than a one-third octave, which is why the "old"
critical-band function, flat at low frequency, fits the direct measurements so
poorly there; above that it is wider. The top axis counts the same curve in
Cams, so equal steps along it are equal numbers of auditory filters.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

f = np.geomspace(50.0, 16000.0, 400)
erb = psychoacoustics.erb_bandwidth(f)
third_octave = f * (2 ** (1 / 6) - 2 ** (-1 / 6))     # 23 % of f, for scale

fig, ax = plt.subplots()
ax.loglog(f, erb, label="ERB$_N$ (Glasberg & Moore, 1990)")
ax.loglog(f, third_octave, "--", label="One-third octave (23 % of f)")
ax.set(xlabel="Centre frequency [Hz]",
       ylabel="Equivalent rectangular bandwidth ERB$_N$ [Hz]")
ax.legend()

# The Cam axis on top: tick where whole ERB_N numbers fall.
cam_ticks = np.arange(5.0, 40.0, 5.0)
ax2 = ax.twiny()
ax2.set_xscale("log")
ax2.set_xlim(ax.get_xlim())
ax2.set_xticks(psychoacoustics.frequency_from_cam(cam_ticks))
ax2.set_xticklabels([f"{c:.0f}" for c in cam_ticks])
ax2.set_xlabel("ERB$_N$ number [Cam]")
plt.show()
```

### `erb_bandwidth()`, `cam_from_frequency()`, `frequency_from_cam()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `frequency` | float or array | Hz | ≥ 0 | `erb_bandwidth`, `cam_from_frequency` |
| `cam` | float or array | Cam | ≥ 0 | `frequency_from_cam` |

Each returns a float for a number and an array for a sequence or an array,
a zero-dimensional one included. The three
constants are exported as `ERB_C1_HZ`, `ERB_C2_PER_HZ` and `CAM_C`.

## Moore-Glasberg loudness (ISO 532-2)

### Which recording maps to which arguments

`field` and `presentation` are not preferences: they are descriptions of how
the sound reached the listener, and getting them wrong costs more than any
difference between the models on this page. ISO 532-2 clause 7.2 lists the
listening situations and the transfer function each needs, and clause 8.1
fixes what the two ears do with the result.

| How the sound was captured | `field=` | Why |
| :--- | :--- | :--- |
| One microphone at the centre of the position the absent listener's head would occupy, one frontal source | `'free'` | Table 1 column 2, the free-field transfer to the tympanic membrane |
| The same microphone in a reverberant room or in situ | `'diffuse'` | Table 1 column 3, the diffuse-field transfer; also the right choice for diffuse-field earphones |
| A probe microphone within 10 mm of the eardrum (5 mm when there are strong components above 3 kHz) | `'eardrum'` | Clause 7.2.4: the spectrum is already at the membrane, so no transfer function is applied |
| A head-and-torso simulator | `'eardrum'`, but only if the simulator is an accurate acoustical model of an average adult | Clause 7.2.5; otherwise it needs its own correction file, which this API cannot express. Equalize the recording to the free or diffuse field first and use the matching option |

![Four capture routes and the arguments each implies: a single microphone where the listener's head would be with one frontal source giving field free, the same microphone in a reverberant field giving field diffuse, a probe microphone within 10 mm of the tympanic membrane giving field eardrum with no transfer function, and a head-and-torso simulator giving field eardrum only if it is an accurate model of an average adult; a footer states that a diotic sound is about 1.5 times as loud as the same sound at one ear](https://docs.jmrp.io/phonometry/media/diagram_mg_capture_routes.svg)

*The four situations of clause 7.2, with the geometry that decides them. The
distances in scene 3 are the standard's own: 10 mm from the tympanic membrane,
5 mm when the sound has strong components above 3 kHz.*

**The failure mode is silent and large.** Applying a free-field transfer to a
signal that already contains the ear-canal resonance double-counts a gain of
about 15 dB near 3 kHz: a 3 kHz tone at 70 dB reads 13.8 sone (78.0 phon) with
`field="free"` and 5.0 sone (62.7 phon) with `field="eardrum"`, and nothing in
the result says which of the two was appropriate. In the other direction, a
free-field recording analysed as `'eardrum'` under-reads by the same amount.

**`presentation` is the other factor of two.** `monaural` computes one ear with
the other silent, `diotic` presents the identical signal to both ears (which
is what a single free-field microphone recording represents, since both ears
hear the same field), and `binaural` combines two independent ear signals
through the standard's inhibition stage. The definitional 1 kHz tone at 40 dB
is 1.000 sone diotically and 0.667 sone monaurally, the 1.5 ratio clause 8.1
states, and the inhibition is why two ears give about one and a half times one
ear rather than exactly twice. For a single-spectrum input `binaural` and
`diotic` coincide, so the distinction only bites for the two-channel input of
`loudness_moore_glasberg_time`. Note also that `loudness_ecma()` offers only
`'free'` and `'diffuse'`, so eardrum-referenced material has to be corrected
before it reaches the ECMA-418-2 model.

Where Zwicker uses fixed critical bands on the Bark scale, Moore-Glasberg builds
an **excitation pattern** with level-dependent rounded-exponential (roex)
auditory filters on the ERB-number ("Cam") scale, then applies a compressive
excitation → specific-loudness transform with $C = 0.0617\ \text{sone/Cam}$
(ISO 532-2:2017, Formula 7) and a binaural-inhibition stage. It reproduces the
tone and broadband cases of Annex B to a percent or two and, unlike ISO 532-1,
models binaural summation explicitly.

```python
import numpy as np
from phonometry import psychoacoustics

# The definitional anchor: one 1 kHz sinusoidal component at 40 dB SPL,
# free field, binaural -> 1 sone / 40 phon by construction of the sone.
res = psychoacoustics.loudness_moore_glasberg_from_spectrum([(1000.0, 40.0)], field="free")
print(f"N = {res.loudness:.3f} sone  ({res.loudness_level:.1f} phon)")   # 1.000 sone (40.0 phon)

# From a calibrated recording: the narrowband (FFT) line spectrum is formed
# (power-preserving normalization) and fed to the exact sinusoidal-component
# method (ISO 532-2 clauses 5.2/5.4).
fs = 48000
x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs)
res = psychoacoustics.loudness_moore_glasberg(x, fs, field="free", presentation="binaural")

res.plot()   # specific loudness N'(i) over the ERB-number (Cam) scale
```

![ISO 532-2 specific loudness over the ERB-number scale for a 1 kHz tone at 40 dB SPL: a single rounded peak near 15 Cam whose area is the total loudness of 1 sone](https://docs.jmrp.io/phonometry/media/moore_glasberg_specific_loudness.svg)

*The ISO 532-2 pattern of the definitional 1 sone anchor. The peak is not a
spectral line but the excitation the roex filters produce around the tone, so
its width is the auditory filter, not the analysis resolution.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

# From a calibrated recording: the narrowband (FFT) line spectrum is formed
# (power-preserving normalization) and fed to the exact sinusoidal-component
# method (ISO 532-2 clauses 5.2/5.4).
fs = 48000
x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * np.arange(fs) / fs)
res = psychoacoustics.loudness_moore_glasberg(x, fs, field="free", presentation="binaural")

# One line — the specific-loudness pattern N'(i) straight from the result:
res.plot()
plt.show()

# Or draw it by hand from the ERB-number grid the result already carries:
fig, ax = plt.subplots()
ax.fill_between(res.erb_number, res.specific, alpha=0.3)
ax.plot(res.erb_number, res.specific)
ax.set_xlabel("ERB number [Cam]")
ax.set_ylabel("Specific loudness N' [sone/Cam]")
plt.show()
```

### From a one-third-octave spectrum (clause 5.5)

The exact method wants sinusoidal components, but clause 5.5 defines the input
a meter actually delivers: the levels of the 29 adjacent one-third-octave bands
from 25 Hz to 16 kHz on the IEC 61260-1:2014 nominal centres. Each band is
assumed flat and expanded internally into an equivalent set of components
before the exact method runs. Two constraints are worth stating plainly:
exactly 29 values and a fixed grid. A meter that logs 20 Hz to 20 kHz has to
be trimmed to it, and one that stops at 8 kHz cannot be used at all.

```python
# `psychoacoustics` is imported by the snippets above.
# A ventilation spectrum as a sound level meter logs it: 29 one-third-octave
# bands, 25 Hz to 16 kHz, in dB SPL.
band_levels = [42.0, 45.0, 48.0, 51.0, 54.0, 56.0, 57.0, 57.0, 56.0, 55.0,
               54.0, 53.0, 52.0, 51.0, 50.0, 49.0, 48.0, 47.0, 46.0, 45.0,
               43.0, 41.0, 39.0, 37.0, 34.0, 31.0, 28.0, 25.0, 22.0]

n_mg = psychoacoustics.loudness_moore_glasberg_from_third_octave(
    band_levels, field="diffuse")
print(f"{n_mg.loudness:.1f} sone  ({n_mg.loudness_level:.1f} phon)")  # 17.4 sone (81.3 phon)

# The same measurement through ISO 532-1, which stops one band earlier:
n_zw = psychoacoustics.loudness_zwicker_from_spectrum(
    band_levels[:28], field="diffuse")
print(f"{n_zw.loudness:.1f} sone  ({n_zw.loudness_level:.1f} phon)")  # 13.8 sone (77.9 phon)
```

The two standards do not even agree on where the spectrum ends: ISO 532-2 takes
29 bands to 16 kHz, ISO 532-1 takes 28 to 12.5 kHz, which is why the slice is
needed. The rest of the gap is the models: roex excitation and explicit
binaural summation against the ISO 532-1 core loudness. Use `field="diffuse"`
for a room measurement made with a free-field-corrected meter; the field
argument is where band-level users most often go wrong.

### `loudness_moore_glasberg()` and its `_from_spectrum` / `_from_third_octave` variants

The three entry points differ only in how the spectrum is supplied and share
`field` and `presentation`.

| Parameter | Applies to | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- | :--- |
| `x` | `loudness_moore_glasberg` | 1D array | Pa | non-empty | Calibrated pressure signal |
| `fs` | `loudness_moore_glasberg` | int | Hz | > 0 | |
| `components` | `_from_spectrum` | list of `(f, L)` | Hz, dB SPL | — | Discrete sinusoidal components |
| `band_levels` | `_from_third_octave` | 29-vector | dB SPL | 25 Hz .. 16 kHz | IEC 61260-1 nominal centres; exactly 29 |
| `field` | all three | str | — | `'free'` (default) / `'diffuse'` / `'eardrum'` | Outer-ear transfer (clause 7.2) |
| `presentation` | all three | str | — | `'binaural'` (default) / `'diotic'` / `'monaural'` | Binaural summation (clause 8.1) |

Returns a `MooreGlasbergLoudness`: `loudness` ($N$, sone), `loudness_level`
(phon), `specific` ($N'(i)$, 372 bins of 0.1 Cam), `erb_number`,
`frequencies`, `field`, `presentation`.

## Time-varying loudness (ISO 532-3)

ISO 532-3 wraps the same excitation / specific-loudness model in a running
multi-resolution spectral analysis (six parallel FFTs, updated every 1 ms) and
two cascaded temporal integrators: the fast **short-term loudness** $S'(t)$
and the slower **long-term loudness** $S''(t)$. The peak long-term loudness
$N_\text{max}$ predicts the loudness of sounds up to about 5 s.

```python
import numpy as np
from phonometry import psychoacoustics

fs = 32000
t = np.arange(int(1.3 * fs)) / fs
x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * t)

res = psychoacoustics.loudness_moore_glasberg_time(x, fs, field="free")
print(f"N_max = {res.n_max:.3f} sone  ({res.loudness_level_max:.0f} phon)")   # 1.000 sone (40 phon)
print(f"long-term loudness exceeded 5% of the time: {res.percentiles[5.0]:.3f} sone")   # 0.999 sone

res.plot()   # short-term S'(t) and long-term S''(t) loudness vs time
```

The short-term loudness rises within a few tens of milliseconds and falls back
slowly, mimicking the ear's fast onset sensitivity and its slower recovery; the
long-term loudness integrates that trace again with a much longer time
constant, so it barely reacts to a single syllable and instead tracks the
overall level of an event. The peak of that slow trace, $N_\text{max}$, is the
standard's predictor of the loudness of a short sound, and its validity stops
at roughly 5 s because beyond that a listener stops judging the sound as one
event. That is also why the percentiles sit beside it: for a sound that
fluctuates without a clear event structure, a percentile of the long-term
loudness (typically the 5 % value) is the stable statistic, where
$N_\text{max}$ would be set by the single worst moment.

![Short-term and long-term Moore-Glasberg loudness traces for a 200 ms 1 kHz burst at 60 dB SPL inside an 0.8 s record: the short-term trace rises to a peak of 4.8 sone within the shaded burst window and releases quickly, while the long-term trace integrates to 3.6 sone and decays slowly after the burst ends](https://docs.jmrp.io/phonometry/media/moore_glasberg_time_loudness.svg)

*A 200 ms 1 kHz burst at 60 dB SPL: the short-term loudness reaches 4.8 sone
within a few tens of milliseconds and releases quickly, while the long-term
loudness integrates to 3.6 sone and decays slowly after the burst ends, the
pair of time constants ISO 532-3 clauses 7.8/7.9 define.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

# The figure is a burst, not a steady tone: 1 kHz at 60 dB SPL, gated on
# between 200 and 400 ms of an 0.8 s record.
fs = 48000
t = np.arange(int(0.8 * fs)) / fs
sig = np.zeros_like(t)
on = (t >= 0.2) & (t < 0.4)
sig[on] = np.sqrt(2) * 2e-5 * 10 ** (60 / 20) * np.sin(2 * np.pi * 1000 * t[on])
burst = psychoacoustics.loudness_moore_glasberg_time(sig, fs)
print(round(float(burst.short_term_loudness.max()), 1),
      round(float(burst.long_term_loudness.max()), 1))   # 4.8  3.6

# The result carries both traces on a 1 ms time axis:
burst.plot()
plt.show()

# Or draw the fast short-term and the slow long-term trace by hand:
fig, ax = plt.subplots()
ax.plot(burst.times, burst.short_term_loudness, label="Short-term S'(t)")
ax.plot(burst.times, burst.long_term_loudness, label="Long-term S''(t)")
ax.set_xlabel("Time [s]")
ax.set_ylabel("Loudness [sone]")
ax.legend()
plt.show()
```

### `loudness_moore_glasberg_time()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D or `(n, 2)` array | Pa | non-empty | Mono = diotic; two columns = left/right ears |
| `fs` | int | Hz | > 0 | |
| `field` | str | — | `'free'` (default) / `'diffuse'` / `'eardrum'` | Outer-ear transfer |
| `presentation` | str | — | `'binaural'` (default) / `'diotic'` / `'monaural'` | Binaural summation |
| `percentiles` | sequence | percent | default `(1, 5, 10, 50, 90, 95)` | Exceeded long-term loudness levels |

Returns a `MooreGlasbergTimeVaryingLoudness`: `times` (1 ms grid),
`short_term_loudness` / `long_term_loudness` (sone), their `_level` in phon,
`n_max`, `loudness_level_max`, a `percentiles` dict, `field`, `presentation`.

## Sottek Hearing Model loudness (ECMA-418-2)

ECMA-418-2:2025 specifies a single auditory front-end (outer/middle-ear
filtering, a 53-band gammatone-like filter bank on the Bark_HMS scale
with $z = 0.5\ ..\ 26.5$, half-wave rectification, block RMS and a compressive
nonlinearity, Formula 23) that is **shared** by its loudness, tonality and
roughness metrics. The loudness $N$ is reported in **sone_HMS**, and the same
1 kHz/40 dB anchor calibrates the front-end. The clean-room implementation
returns 0.9845 sone_HMS for that anchor rather than exactly 1: the 1.55 %
residual comes from the mandated Clause 6.2.3 band averaging across the
block-size-boundary bands excited by the tone's lower flank, near 800 to
900 Hz. Without any band averaging the chain reads 0.955, with averaging
restricted to same-block-size neighbours 0.996, and with the full
cross-group recomputation the standard requires 0.9845. The calibration
constant $c_\mathrm{N}$ is kept at its verbatim tabulated value rather than retuned,
which is why the deviation is visible at all; the
[`psychoacoustics.loudness.ecma` API reference](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/ecma/)
carries the full account.

```python
import numpy as np
from phonometry import psychoacoustics

fs = 48000
t = np.arange(int(1.2 * fs)) / fs
x = np.sqrt(2) * 2e-5 * 10 ** (40 / 20) * np.sin(2 * np.pi * 1000 * t)

res = psychoacoustics.loudness_ecma(x, fs, field="free")
print(f"N = {res.loudness:.4f} sone_HMS")   # 0.9845 sone_HMS
print(res.specific_loudness.shape)          # (53,) average specific loudness N'(z)

res.plot()   # average specific loudness N'(z) + time-dependent N(l) at 187.5 Hz
```

![Sottek Hearing Model average specific loudness N'(z) over the 53 Bark_HMS bands for a 1 kHz tone at 60 dB SPL totalling 2.8 sone_HMS, peaking at the tone's critical band near 9 Bark_HMS and falling away on both sides](https://docs.jmrp.io/phonometry/media/sottek_specific_loudness.svg)

*The 1 kHz tone at 60 dB SPL, N = 2.8 sone_HMS, a louder tone than the 40 dB
anchor of the snippet above, which gives 0.98 sone_HMS. The loudness is the
area under $N'(z)$, so a broadband sound spreading a low pattern over many
bands can outweigh this single peak.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import psychoacoustics

# The figure is the 60 dB tone, not the 40 dB anchor of the snippet above.
fs = 48000
t = np.arange(int(1.2 * fs)) / fs
x = np.sqrt(2) * 2e-5 * 10 ** (60 / 20) * np.sin(2 * np.pi * 1000 * t)
res = psychoacoustics.loudness_ecma(x, fs, field="free")
print(f"N = {res.loudness:.1f} sone_HMS")   # 2.8 sone_HMS

# The result carries the average specific loudness over the 53 Bark_HMS bands:
res.plot()
plt.show()

# Or draw N'(z) by hand against the critical-band-rate scale:
fig, ax = plt.subplots()
ax.fill_between(res.bark, res.specific_loudness, alpha=0.3)
ax.plot(res.bark, res.specific_loudness)
ax.set_xlabel(r"Critical-band rate $z$ [$\mathrm{Bark}_\mathrm{HMS}$]")
ax.set_ylabel(r"Specific loudness $N'$ [$\mathrm{sone}_\mathrm{HMS}/\mathrm{Bark}_\mathrm{HMS}$]")
plt.show()
```

### `loudness_ecma()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `x` | 1D array | Pa | non-empty | Calibrated pressure signal |
| `fs` | float | Hz | > 0 | Resampled to 48 kHz internally if needed (Clause 5.1.1) |
| `field` | str | — | `'free'` (default) / `'diffuse'` | Outer/middle-ear filter (Clause 5.1.3) |

Returns an `EcmaLoudness`: `loudness` ($N$, sone_HMS), `specific_loudness`
($N'(z)$, 53 bands), `bark`, `frequencies`, `times`, `loudness_vs_time`
($N(l)$ at 187.5 Hz), `basis_loudness_vs_time` ($N_\text{basis}(l)$,
sone_HMS, at the same `times`), `last_evaluated_block` ($l_\text{end}$ of
Formula 40), `field`.

**Is the sound audible?** Clause 5.1.9 calls a signal audible when its total
basis loudness exceeds 0.01 sone_HMS, the
`psychoacoustics.AUDIBILITY_THRESHOLD_SONE_HMS` the package publishes. That
total, $N_\text{basis}$ of Formula (26), is the specific basis loudness
$N'_\text{basis}$ of Formula (25), the output of the front-end before any
tonal or noise split, summed over the 53 bands with $\Delta z = 0.5$.
`loudness_ecma()` returns it block by block as `basis_loudness_vs_time`, on
the 187.5 Hz grid of `times`: each band is computed at the block size Clause
5.1.5.1 gives it for loudness (Table 4) and resampled to that grid, as Clause
6.2.6 resamples the tonal and noise loudness. Clause 5.1.9 prints Formula (26)
without a time index and names no segmentation, so one value per block of
this segmentation is this library's reading; roughness and fluctuation
strength segment by Clause 5.1.5.2 instead, and for a sound that changes in
time they form a different total. No function applies the criterion. The
library compares it with every block up to `last_evaluated_block`, the
$l_\text{end}$ of Formula (40), and calls the sound audible when one of them
exceeds it, a reading of its own too, since Clause 5.1.9 says neither: the
blocks after $l_\text{end}$ hold the zero padding whose results Clause 6.2.6
removes, where a sound cut off abruptly leaves the auditory filters ringing.
Compare that total, not `loudness`, which is the $N$ of Formula (117),
assembled from the tonal and noise loudness of Clause 8. A tone at the edge of
hearing can leave $N$ below the criterion while its basis loudness clears it:

```python
# `np`, `fs`, `t` and `psychoacoustics` come from the snippet above.
# A 1 kHz tone at 0 dB SPL, at the edge of hearing.
quiet = np.sqrt(2) * 2e-5 * 10 ** (0 / 20) * np.sin(2 * np.pi * 1000 * t)
faint = psychoacoustics.loudness_ecma(quiet, fs, field="free")

# N_basis(l) of the blocks that hold the signal, l = 0 to l_end (Formula 40).
n_basis = faint.basis_loudness_vs_time[: faint.last_evaluated_block + 1]
audible = n_basis > psychoacoustics.AUDIBILITY_THRESHOLD_SONE_HMS
print(f"N = {faint.loudness:.4f} sone_HMS")           # 0.0034 sone_HMS: N of Formula 117
print(f"max N_basis = {n_basis.max():.4f} sone_HMS")  # 0.0118 sone_HMS
print(audible.any())   # True: above the criterion in a block, the library's reading
```

## What this guide covers

- **Covered.** The Glasberg and Moore (1990) ERB_N bandwidth and Cam scale of Moore
  6e pp. 76-77, via `erb_bandwidth()`, `cam_from_frequency()` and
  `frequency_from_cam()`. ISO 532-2:2017 (Moore-Glasberg): the roex excitation
  pattern of clause 7 and the binaural inhibition of clause 8, via
  `loudness_moore_glasberg()` and its `_from_spectrum`/`_from_third_octave`
  variants. ISO 532-3:2023 (Moore-Glasberg-Schlittenlacher): the short-term
  loudness of clause 7.8, the long-term loudness of clause 7.9 and its peak
  $N_\text{max}$, via `loudness_moore_glasberg_time()`. ECMA-418-2:2025 (Sottek
  Hearing Model): the loudness assembly of Clause 8, and the total basis
  loudness of Formula 26 that the audibility criterion of Clause 5.1.9 reads,
  via `loudness_ecma()`.

- **Not covered.** ECMA-418-2's binaural combination (Formula 118, Clause 8.1.5) is not
  implemented: `loudness_ecma()` is monaural, so analyse each ear channel
  separately. The audibility criterion of Clause 5.1.9 is published as a
  constant and applied by no function: compare the total basis loudness with
  it, block by block up to `last_evaluated_block`. ISO 532-3 Clause 5
  prescribes resampling the input to 32 kHz before the running FFT analysis.
  This implementation processes at the native sampling rate instead, a
  documented deviation that stays inside the standard's expanded uncertainty.
  Resample to 32 kHz first if strict clause-by-clause conformance matters.

## See also

- [Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/loudness/): the Zwicker reference method
  (ISO 532-1), its accredited fiche and the ISO 226 equal-loudness contours.
- [Sound Quality Metrics](https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/): the tonality,
  roughness and fluctuation strength built on the same ECMA-418-2 front-end.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/perception/): the equations behind the loudness models.
- API reference: [`psychoacoustics.loudness.moore_glasberg`](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/moore-glasberg/), [`psychoacoustics.loudness.moore_glasberg_time`](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/moore-glasberg-time/) and [`psychoacoustics.loudness.ecma`](https://docs.jmrp.io/phonometry/reference/api/psychoacoustics/ecma/).
- Theory: [Advanced loudness models and sound quality](https://docs.jmrp.io/phonometry/reference/theory/perception/#advanced-loudness-models--sound-quality): what the Moore-Glasberg and Sottek models change relative to Zwicker, and why the three disagree where they do.

## Quick answers

### Which loudness model should I choose: Zwicker, Moore-Glasberg or Sottek?

The Zwicker method (ISO 532-1:2017) is the reference: stationary and time-varying, one-third-octave input, fast and widely cited. Moore-Glasberg (ISO 532-2:2017) is stationary, builds roex excitation patterns and models binaural summation explicitly; ISO 532-3:2023 adds time-varying short- and long-term loudness with the peak $N_\text{max}$. The Sottek model (ECMA-418-2:2025) reports sone_HMS and shares its auditory front-end with the ECMA tonality and roughness metrics.

## References

- **Ecma International. (2025).** [*Psychoacoustic metrics for ITT equipment — Part 2 (methods for describing human perception based on the Sottek Hearing Model)*](https://ecma-international.org/publications-and-standards/standards/ecma-418/) (ECMA-418-2:2025).
  The Sottek Hearing Model loudness (sone_HMS), in the 4th edition of June 2025.
- **International Organization for Standardization. (2017).** [*Acoustics — Methods for calculating loudness — Part 2: Moore-Glasberg method*](https://www.iso.org/standard/63078.html) (ISO 532-2:2017).
  Stationary loudness from roex excitation patterns on the ERB-number scale, with explicit binaural summation.
- **International Organization for Standardization. (2023).** [*Acoustics — Methods for calculating loudness — Part 3: Moore-Glasberg-Schlittenlacher method*](https://www.iso.org/standard/69856.html) (ISO 532-3:2023).
  Time-varying short-term and long-term loudness and the peak N_max.
- **Moore, B. C. J. (2013).** *An introduction to the psychology of hearing* (6th ed.). Brill. https://doi.org/10.1163/9789004252424
  The ERB_N auditory-filter bandwidth and the Cam (ERB_N number) scale of Glasberg and Moore (1990), pp. 76-77.