# Noise-induced hearing loss (ISO 1999)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/perception/hearing/noise-induced-hearing-loss/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/perception/hearing/noise-induced-hearing-loss/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-09
Updated: 2026-10-21T12:42:42Z
Standards: ISO 1999:2013
Verified: 6 conformance checks (ISO 1999:2013) https://docs.jmrp.io/phonometry/reference/conformance/#noise-induced-hearing-loss-iso-1999
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: ISO 1999:2013 noise-induced permanent threshold shift (NIPTS) by level, duration and frequency, combined with ISO 7029 age into HTLAN, 500 to 6000 Hz.

---

**ISO 1999:2013** estimates the hearing loss a population suffers from
occupational noise. It gives the **noise-induced permanent threshold shift**
(NIPTS), the extra hearing loss caused by the noise, on top of ageing, as a
function of the exposure level, the exposure duration and the audiometric
frequency, together with its spread across a population. It then combines the
noise component with the age component (the ISO 7029 threshold, "database A")
into the **hearing threshold level associated with age and noise** (HTLAN).
Both are defined at the six audiometric frequencies 500 Hz to 6000 Hz, where
noise damage concentrates (the characteristic 4 kHz notch).

![Two converging lanes: age, sex and a fractile give the age threshold H (HTLA, ISO 7029); the 8-hour-normalised level and duration give the median NIPTS N50 and then the fractile NIPTS N; the two combine into HTLAN = H + N - H\*N/120](https://docs.jmrp.io/phonometry/media/diagram_nihl.svg)

## 1. Noise-induced permanent threshold shift (clause 6.3)

The median NIPTS for exposure durations of 10 to 40 years grows with the square
of the excess of the noise exposure level over a frequency-dependent cut-off
$L_0$ (ISO 1999 clause 6.3.1, Formula 2, Table 1):

$$
N_{50} = \left[u + v\,\log_{10}\frac{t}{t_0}\right](L_\mathrm{EX,8h} - L_0)^2,
$$

with $t$ the exposure in years and $t_0 = 1$ year; below $L_0$ the effect is
zero. A population **fractile** follows from two half-Gaussians whose spreads
$d_\mathrm{u}$ (worse than the median) and $d_\mathrm{l}$ (better) are given by Formulae 6/7 and
Table 3: $N_{50} + z\,d$ with $z$ the standard-normal quantile, clamped at
zero (clause 6.3.2).

The `fractile` argument is the fraction of the population *below* the returned
value, so `fractile=0.9` is the most-susceptible tenth. Note that ISO 1999
writes its own percentage $Q$ the other way round: in Formulae (4)/(5) $Q$ is
the percentage with *worse* hearing, so that same tenth is $Q = 10\;\%$, which
is how the `.report()` fiche prints it and how the Annex D columns are headed.

```python
from phonometry import hearing

# Median NIPTS after 20 years at an 8 h-normalised level of 90 dB(A).
r = hearing.nipts(90.0, 20.0, fractile=0.5)
print(r.frequencies.astype(int))  # [ 500 1000 2000 3000 4000 6000]
print(r.median.round(1))          # [ 0.   0.1  4.1 10.2 12.9  8.5]

# The most-susceptible tenth of the population (90th percentile):
print(hearing.nipts(90.0, 20.0, fractile=0.9).value.round(1))
# [ 0.   0.1  7.7 16.2 17.8 13.6]

r.plot()   # the NIPTS spectrum with its fractile band (needs matplotlib)
```

The shift peaks near 4 kHz and deepens with both level and duration. Below the
cut-off (here 500 Hz, $L_0 = 93$ dB, and 1000 Hz, $L_0 = 89$ dB, at 90 dB)
the noise causes no permanent shift. For durations under 10 years the median is
extrapolated from the 10-year value (Formula 3); a subset of the frequencies
can be requested with `frequencies=`.

**What $L_\mathrm{EX,8h}$ must be.** The first argument is the A-weighted noise
exposure level normalised to a nominal eight-hour day, in practice the result
of an
[ISO 9612 survey](https://docs.jmrp.io/phonometry/perception/hearing/occupational-exposure/) of the
homogeneous exposure group, which is the standard ISO 1999 references
normatively for it. It is the level **at the unprotected ear**: the Scope says
in as many words that none of its levels account for hearing protectors, which
would both reduce the effective exposure and change the spectrum at the ear, so
feeding an attenuated or "effective" level is not a conservative shortcut but a
different quantity. Report the protector separately. The model also treats the
level as constant over the whole duration, so a career of changing jobs is
split into segments and each predicted on its own level rather than averaged
first: Formula (2) is quadratic in the excess over $L_0$, so averaging before
squaring under-predicts. And the duration is *exposure* years, not age and not
years of employment.

The level is also the variable a hearing-conservation decision acts on, and it
is the one the two figures on this page hold fixed:

![Two panels. Left: the median NIPTS after 40 years against the 8-hour-normalised exposure level from 75 to 100 dB(A), one curve per audiometric frequency; each curve leaves zero at its own cut-off level L0 of 93, 89, 80, 77, 75 and 77 dB, marked with a dot, and then grows quadratically, the 4000 Hz curve reaching about 41 dB at 100 dB(A). Right: the 4000 Hz curve alone for 10, 20, 30 and 40 years, with two arrows showing that a 3 dB step from 85 to 88 dB(A) adds 4.5 dB of shift while the same step from 95 to 98 dB(A) adds 8.4 dB](https://docs.jmrp.io/phonometry/media/nipts_level_growth.svg)

*Below its cut-off $L_0$ the model returns exactly zero, and above it the shift
is quadratic in the excess, so equal decibel reductions are worth
progressively more the louder the job. On the right, at 4 kHz over a 40-year
career, taking 3 dB off an 88 dB(A) job recovers 4.5 dB of median shift, while
taking the same 3 dB off a 98 dB(A) job recovers 8.4 dB. That asymmetry, not
the notch shape, is what a control measure is bought against.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `hearing` and the result `r` come from the first snippet on this page.
levels = np.arange(75.0, 100.5, 0.5)
fig, (ax_f, ax_t) = plt.subplots(1, 2, figsize=(12.5, 5.4))
for k, f in enumerate(r.frequencies):
    ax_f.plot(levels, [hearing.nipts(x, 40.0, 0.5).median[k] for x in levels],
              label=f"{f:g} Hz")
ax_f.legend()

for years in (10, 20, 30, 40):
    ax_t.plot(levels, [hearing.nipts(x, years, 0.5).median[4] for x in levels],
              label=f"{years} yr")     # index 4 is 4000 Hz
ax_t.legend()
plt.show()
```

A longer, louder career makes the shape unmistakable:

![ISO 1999 noise-induced permanent threshold shift after 40 years at an 8 h-normalised 95 dB(A), on an inverted audiogram axis from 500 Hz to 6000 Hz: the median is near zero at 500 Hz and deepens to about 26 dB at 4000 Hz before recovering at 6000 Hz, and the 10 to 90 percent fractile band around it reaches nearly 37 dB for the most susceptible tenth](https://docs.jmrp.io/phonometry/media/nipts_audiogram.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import hearing

# 40 years at an 8 h-normalised 95 dB(A), most-susceptible tenth.
res = hearing.nipts(95.0, 40.0, fractile=0.9)
print(res.median.round(1))    # the median N50
print(res.value.round(1))     # the 90 % fractile

# One line: the median, the fractile and the 10-90 % band.
res.plot()
plt.show()
```

The notch at 3 kHz to 4 kHz, with partial recovery at 6 kHz, is the signature
of noise damage and the reason audiometric surveillance tests those
frequencies. It comes out of the model rather than being imposed on it: the
cut-off level $L_0$ and the coefficients $u$, $v$ of Table 1 are lowest where
the ear is most vulnerable, so the same $L_\mathrm{EX,8h}$ buys far more shift at
4 kHz than at 500 Hz.

### Where the model applies

Formula (2) is a quadratic with no upper bound, so it keeps returning
plausible-looking numbers well outside the data that fitted it. Four limits
matter, and the library says so at three of them by raising
`NoiseInducedHearingLossWarning`:

- **Duration.** The median is specified for 10 to 40 years, with Formula (3)
  extrapolating down to 1 year. A six-month exposure or a fifty-year career is
  outside the fitted range and warns.
- **Level.** The Annex D worked examples span 85 dB to 100 dB, and Scope NOTE 4
  restricts validity to the stated ranges of levels; above 100 dB the guide
  warns, and use above 200 Pa (140 dB) is recognised as extrapolation by the
  Scope itself.
- **Fractile.** Clause 6.3.2 calls the tails below $Q$ = 5 % and above 95 %
  unreliable and says they should not be estimated, so the 0.9 / 0.1 pair used
  in the examples above already sits close to the practical edge, and anything
  beyond warns.
- **The character of the noise.** This one is silent, because no argument
  carries it. Scope NOTE 3 says the prediction method is based primarily on
  data collected with essentially **broadband, steady, non-tonal** noise, and
  the Scope covers noise below roughly 10 kHz that is steady, intermittent,
  fluctuating or irregular. An impulsive or strongly tonal exposure is
  therefore a use outside the evidence rather than a computation error, and the
  Introduction sets blast and high-impulse noise apart explicitly. NOTE 4 adds
  a second silent limit: the simplifications behind the data assume a daily
  exposure duration no longer than 12 h.

### NIPTS report (`.report()`)

`NIPTSResult.report(path)` renders a one-page PDF fiche laid out like the
noise-induced hearing loss prediction an occupational-hygiene service issues
for an exposure group, following **ISO 1999:2013** (clause 6.3): a
prediction-basis line, an optional metadata header block (company,
worker(s)/group, workplace and date of assessment), a table of the median
$N_{50}$ and the fractile NIPTS at the six audiometric frequencies beside the
result's own spectrum plot with its fractile band, the boxed shift averaged
over the 2/3/4 kHz hearing-handicap set together with the exposure conditions
($L_\mathrm{EX,8h}$, the duration in years and the population percentage $Q$), and the
notes that keep the fiche honest: the values are a statistical prediction for
the exposed population rather than anyone's audiogram, and ISO 1999 leaves the
choice of handicap frequencies to the user. `verbose=True` adds the spread
columns $d_\mathrm{u}$/$d_\mathrm{l}$; a `requirement` in the metadata is read as the maximum
acceptable representative NIPTS and adds a PASS/FAIL row (a smaller shift
passes). Rendering needs reportlab and matplotlib
(`pip install "phonometry[report,plot]"`); only `engine="reportlab"` is
supported, and `language="es"` renders a Spanish fiche.

```python
from phonometry import hearing, ReportMetadata

# The 90 dB(A) / 20 year case above, most-susceptible tenth.
res = hearing.nipts(90.0, 20.0, fractile=0.9)
res.report(
    "nipts_fiche.pdf",
    metadata=ReportMetadata(
        client="Example fabrication works",
        specimen="Welders (homogeneous exposure group, 4 workers)",
        test_room="Steel assembly hall, line 2",
    ),
)                                   # NIPTS averaged over 2/3/4 kHz (dB)
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [ISO 1999 NIPTS prediction example report (PDF)](https://docs.jmrp.io/phonometry/media/iso1999_nipts_example.pdf): One-page noise-induced hearing loss prediction fiche: a metadata header (company, worker group, workplace, date of assessment), a table of the median N50 and the NIPTS at the requested fractile from 500 Hz to 6000 Hz (12.9 dB and 17.8 dB at 4000 Hz), the spectrum plot with its 10-90 % fractile band, and the boxed predicted NIPTS averaged over 2/3/4 kHz = 13.9 dB for a noise exposure LEX,8h = 90 dB over 20 years at population fractile Q = 10 %.

NIPTS prediction fiche (NIPTSResult.report), the shift averaged over the 2/3/4 kHz hearing-handicap set.

## 2. Age and noise combined: HTLAN (clause 6.1)

The noise component does not simply add to the age component: ISO 1999
Formula (1) combines them with a compression term that matters once the total
exceeds about 40 dB:

$$
H' = H + N - \frac{H\,N}{120},
$$

where $H$ is the age threshold (HTLA, from ISO 7029 at the same fractile) and
$N$ the NIPTS. `htlan` evaluates both components and their combination.

```python
from phonometry import hearing

# A 60-year-old man, 30 years at 95 dB(A), median.
h = hearing.htlan(60, "male", 95.0, 30.0, fractile=0.5)
print(h.htla.round(1))       # [ 6.   7.8 12.5 16.6 20.2 25.9]  age alone
print(h.nipts.round(1))      # [ 0.5  3.  11.8 21.6 24.8 17.6]  noise alone
print(h.threshold.round(1))  # [ 6.5 10.7 23.  35.2 40.8 39.8]  age + noise

h.plot()   # the three curves of the figure below: HTLA, NIPTS and HTLAN
```

At 4 kHz the age component (20.2 dB) and the noise component (24.8 dB) combine
to 40.8 dB rather than their 45.0 dB sum; the compression term removes 4.2 dB.

![Two panels. Left: the median NIPTS at 95 dB for 10, 20, 30 and 40 years on an inverted audiogram axis with the 10 to 90 percent band around the 40-year curve, deepening toward 4 kHz. Right: for a 60-year-old man exposed 30 years at 95 dB, the age (HTLA), noise (NIPTS) and combined HTLAN curves, the HTLAN lying below the simple sum](https://docs.jmrp.io/phonometry/media/noise_induced_hearing_loss.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import hearing

# One line for the NIPTS spectrum with its fractile band:
result = hearing.nipts(95.0, 40.0, 0.9)
result.plot()
plt.show()
f = result.frequencies   # the six audiometric frequencies of the standard

# By hand, both panels:
fig, (ax1, ax2) = plt.subplots(1, 2, figsize=(12.5, 5.6))
for yr in (10, 20, 30, 40):
    ax1.plot(f, hearing.nipts(95.0, yr, 0.5).median, "o-", label=f"{yr} yr")
ax1.set_xscale("log"); ax1.invert_yaxis(); ax1.legend()

h = hearing.htlan(60, "male", 95.0, 30.0, 0.5)
ax2.plot(f, h.htla, "o-", label="Age (HTLA)")
ax2.plot(f, h.nipts, "^-", label="Noise (NIPTS)")
ax2.plot(f, h.threshold, "s--", label="Age + noise (HTLAN)")
ax2.set_xscale("log"); ax2.invert_yaxis(); ax2.legend()
plt.show()
```

**Three quantities, kept distinct.** It is worth being precise about what each
symbol means, because they are easy to conflate:

- **NIPTS** ($N$) is the *noise-induced permanent threshold shift*: the extra
  loss the noise causes, and nothing else. It is what an ideal hearing-
  conservation programme would prevent. On its own it is not an audiogram.
- **HTLA** ($H$) is the *age* threshold alone (the ISO 7029 component of the
  [hearing-threshold](https://docs.jmrp.io/phonometry/perception/hearing/hearing-threshold/) guide), the loss
  the same person would have with no occupational noise.
- **HTLAN** ($H'$) is the *total* threshold: age **and** noise combined by
  Formula (1). This is what an audiometer measures, and the only one of the
  three you can compare against a real audiogram.

The non-linear combination $H' = H + N - HN/120$ is why you cannot simply read
NIPTS off a measured audiogram by subtracting an age table: near-total losses
would otherwise exceed the ~120 dB physiological ceiling, so the standard
compresses the sum. Because the correction $HN/120$ scales with the *product*
of the two components, it can already shave a few dB while $H + N$ is below
40 dB; 40 dB is only a rough marker for where the effect becomes noticeable,
not a hard boundary, and the correction grows steadily in the regime of a
long, loud exposure where both terms are large.

![A filled contour map of the decibels removed by the HN/120 term over the plane of the age component H from 0 to 60 dB against the noise component N from 0 to 60 dB. The removed amount is a hyperbolic family growing from 0 in the bottom-left corner to about 30 dB at H = N = 60 dB. The dashed line where H + N equals 40 dB crosses contours of between about 2 and 3 dB rather than following one, and the worked case at H = 20.2 and N = 24.8 dB is marked, where 4.2 dB is removed from the 45.0 dB sum](https://docs.jmrp.io/phonometry/media/htlan_compression.svg)

*The correction is a product, so it has no threshold: the dashed $H + N = 40$ dB
line cuts across the contours instead of following one. A large age component
makes a modest noise component compress, and the other way round: 4.2 dB is
already gone at the worked case, and a worker with 40 dB from each cause loses
13.3 dB from the sum.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `hearing` is the import of the first snippet on this page.
grid = np.linspace(0.0, 60.0, 121)
h, n = np.meshgrid(grid, grid)
removed = h + n - hearing.age_and_noise_threshold(h, n)
print(round(float(removed[-1, -1]), 1))          # 30.0 dB at H = N = 60

fig, ax = plt.subplots(figsize=(8.2, 6.4))
cs = ax.contourf(h, n, removed, levels=np.arange(0.0, 31.0, 2.0), cmap="YlOrRd")
fig.colorbar(cs, ax=ax)
ax.plot([0.0, 40.0], [40.0, 0.0], "--")          # H + N = 40 dB
plt.show()
```

### Comparing with a measured audiogram

HTLAN is comparable only with an audiogram taken the way the underlying
databases were taken, and ISO 1999 makes the technique part of the comparison
rather than an implementation detail: clause 6.2.3 states that because
audiometric measurement techniques affect threshold measurements, the same
technique should be used to establish the HTLA database as is used to obtain or
verify the threshold of the noise-exposed population. Change the earphone or
the threshold procedure and the offset between measured and predicted moves.
In practice that means:

- **Pure-tone air conduction.** Annex A.1 says database A *is* the ISO 7029
  distribution of the normal threshold of hearing by air conduction, so a bone
  conduction threshold is not the quantity being predicted.
- **A declared, calibrated earphone.** dB HL is transducer-specific: 0 dB HL is
  the reference equivalent threshold sound pressure level of ISO 389-1
  (supra-aural), ISO 389-2 (insert) or ISO 389-8 (circumaural) for the earphone
  actually fitted. Record which, and its calibration.
- **A stated threshold procedure.** ISO 8253-1:2010 clause 6.2.3 specifies two
  manual procedures, ascending and bracketing, which differ only in the
  sequence of presentations and, properly carried out, give substantially the
  same thresholds. Record which one, and note that a procedure outside that
  clause can move the threshold by several decibels on average.
- **The same six frequencies.** `nipts` and `htlan` return 500, 1000, 2000,
  3000, 4000 and 6000 Hz. An audiogram that omits 3 kHz or 6 kHz cannot be
  compared where the noise notch lives.
- **A fixed ear convention.** Worse ear, better ear or the two-ear average are
  three different comparisons against the same prediction, and ISO 1999 leaves
  the choice to the user, so it belongs in the report rather than in the
  analyst's head.
- **A noise-free interval before the test.** NIPTS is *permanent* shift, and it
  is preceded by a reversible temporary threshold shift; ISO 8253-1 clause 5.1
  says significant noise exposure before audiometry shall be avoided or else
  noted. A mid-shift audiogram measures TTS on top of the permanent loss and
  will exceed the predicted HTLAN for a reason the model does not describe.
  Record the elapsed time since the last exposure.

One caution that applies to the whole comparison: the Scope states that the
standard is based on statistical data and cannot be applied to the prediction
or assessment of an individual's hearing loss except in terms of statistical
probabilities. A single audiogram sitting above the median is not evidence of
anything; a *distribution* of audiograms sitting above the predicted fractiles
is.

**Fence caveats.** ISO 1999 gives thresholds and their distribution; it does
*not* define a "hearing handicap" or a compensable fence. A **fence** is a
policy line (commonly a 25 dB average over selected frequencies) above which
hearing is deemed impaired, and it lives in national regulation, not in this
standard. Two cautions follow. First, the fence frequencies matter: averaging
over 0.5/1/2 kHz (a classic speech fence) barely sees the 3–6 kHz noise notch,
so it under-reports early noise damage that a 3/4/6 kHz average would catch.
Second, NIPTS and HTLAN answer different fence questions: NIPTS asks "how much
did the noise add", HTLAN "is this ear, age included, over the line"; and a
population's *percentage beyond fence* depends on the fractile spread, not just
the median, so it must be read from the distribution, never from the median
threshold alone.

The `NIPTSResult` carries the `median` ($N_{50}$), the
`spread_upper`/`spread_lower`
and the `value` at the requested fractile; the `HTLANResult` carries `htla`,
`nipts` and the combined `threshold`. Both expose `.plot()`. The age component
alone is the subject of the
[hearing-threshold](https://docs.jmrp.io/phonometry/perception/hearing/hearing-threshold/) guide.

### HTLAN report (`.report()`)

`HTLANResult.report(path)` renders the companion fiche for the combined
threshold, following **ISO 1999:2013** clause 6.1: the same prediction-basis
line and metadata header as the NIPTS fiche, but a table that carries the age
component $H$, the noise component $N$ and the combined $H'$ at each
audiometric frequency, beside the three-curve plot, with the boxed threshold
averaged over the 2/3/4 kHz hearing-handicap set and the listener and exposure
conditions (age and sex, $L_\mathrm{EX,8h}$ over the exposure years, and the
population percentage $Q$). Its notes add the one that matters here: the age
component is database A evaluated from ISO 7029:2017, whose values differ from
the illustrative Table A.3 selection of ISO 1999, which derives from an earlier
edition. `verbose=True` adds the compression term $HN/120$ as its own column,
and a `requirement` in the metadata is read as the maximum acceptable
representative HTLAN.

```python
from phonometry import hearing, ReportMetadata

# The 60-year-old machine operator of this section, median.
res = hearing.htlan(60, "male", 95.0, 30.0, fractile=0.5)
res.report(
    "htlan_fiche.pdf",
    metadata=ReportMetadata(
        client="Example fabrication works",
        specimen="Machine operator (60 years, 30 years in role)",
        test_room="Steel assembly hall, line 2",
    ),
)                                   # HTLAN averaged over 2/3/4 kHz (dB HL)
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [ISO 1999 HTLAN prediction example report (PDF)](https://docs.jmrp.io/phonometry/media/iso1999_htlan_example.pdf): One-page hearing threshold level prediction fiche for age and noise: a metadata header, a table of the age component H, the noise component N and the combined threshold H' from 500 Hz to 6000 Hz (20.2, 24.8 and 40.8 dB at 4000 Hz), the plot of the three curves, and the boxed predicted hearing threshold level averaged over 2/3/4 kHz = 33.0 dB HL for a 60-year-old male listener exposed at LEX,8h = 95 dB over 30 years at population fractile Q = 50 %.

Age-plus-noise threshold fiche (HTLANResult.report), the HTLAN averaged over the 2/3/4 kHz hearing-handicap set.

## What this guide covers

- **Covered.** ISO 1999:2013 as implemented by `nipts` and `htlan`: the median NIPTS of
  clause 6.3.1 (Formula 2, extrapolated below 10 years by Formula 3, Table 1)
  and its population fractile of clause 6.3.2 (Formulae 4-7, Tables 2-3),
  together with the HTLAN combination of clause 6.1 (Formula 1) run by
  `age_and_noise_threshold`, all validated against the Annex D worked examples.
  The age component is database A, evaluated from ISO 7029:2017, the edition
  clause 6.2.2 references undated.

- **Not covered.** Clauses 6.2.3 and 6.2.4 let the user substitute a database B for database A:
  an age threshold measured on a control population of the country under
  consideration. Only database A is implemented, so `htlan` always draws its age
  component from ISO 7029:2017. `age_and_noise_threshold` accepts an external HTLA
  array for that case, but computing database B itself is not phonometry's job.
  ISO 1999 does not define a "hearing handicap" or a compensable fence: that
  line is set by national regulation, and nothing here applies one, so you must
  supply and check it yourself.

## See also

- [Occupational noise exposure](https://docs.jmrp.io/phonometry/perception/hearing/occupational-exposure/): the
  ISO 9612 survey that produces the $L_\mathrm{EX,8h}$ this model consumes, and the
  uncertainty that comes with it.
- [Hearing threshold](https://docs.jmrp.io/phonometry/perception/hearing/hearing-threshold/): the ISO 7029 age
  component $H$ this model adds the noise component to, and the ISO 389-7 zero
  the dB HL scale is referred to.
- [Speech Intelligibility Index](https://docs.jmrp.io/phonometry/perception/speech/speech-intelligibility/): what a
  shifted threshold costs in speech audibility, which is the consequence a
  worker actually notices.
- API reference: [`hearing.noise_induced_hearing_loss`](https://docs.jmrp.io/phonometry/reference/api/hearing/noise-induced-hearing-loss/).
- Theory: [Noise-induced hearing loss (ISO 1999)](https://docs.jmrp.io/phonometry/reference/theory/perception/#noise-induced-hearing-loss-iso-1999): the ISO 1999 threshold-shift model, its median and its percentile spread.

## References

- **International Organization for Standardization. (2013).** [*Acoustics — Estimation of noise-induced hearing loss*](https://www.iso.org/standard/45103.html) (ISO 1999:2013).
  The implemented model: the HTLAN combination (clause 6.1, Formula 1), the median NIPTS (clause 6.3.1, Formulae 2-3, Table 1) and its statistical distribution (clause 6.3.2, Formulae 4-7, Tables 2-3), validated against the worked examples of Annex D. The age component (database A) is ISO 7029:2017.
- **National Institute for Occupational Safety and Health. (1998).** [*Criteria for a recommended standard: Occupational noise exposure — Revised criteria 1998*](https://www.cdc.gov/niosh/docs/98-126/pdfs/98-126.pdf) (DHHS/NIOSH Publication No. 98-126). https://doi.org/10.26616/NIOSHPUB98126
  A freely available criteria document (the linked PDF is the free download) reviewing the same exposure-response evidence and the fence and hearing-conservation issues discussed on this page.
- **Passchier-Vermeer, W. (1974).** Hearing loss due to continuous exposure to steady-state broad-band noise. *The Journal of the Acoustical Society of America*, *56*(5), 1585-1593. https://doi.org/10.1121/1.1903482
  One of the field studies whose exposure-response data underpin the NIPTS relations later codified in ISO 1999.
