# Dynamic stiffness of resilient materials

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/materials/resilient/dynamic-stiffness/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/materials/resilient/dynamic-stiffness/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-11
Updated: 2026-10-21T12:42:46Z
Standards: EN 29052-1:1992 (ISO 9052-1:1989)
Verified: 3 conformance checks (EN 29052-1:1992 (ISO 9052-1:1989)) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Dynamic stiffness per unit area of resilient layers under floating floors by EN 29052-1:1992, and the floor's natural frequency.

---

A **floating floor** is a heavy floating slab resting on a resilient layer; the
two form a mass-spring system whose **natural frequency** governs how much the
floor improves impact and airborne insulation. **EN 29052-1:1992** (identical to
ISO 9052-1:1989) measures the **dynamic stiffness per unit area** $s'$ of the
resilient layer from the resonance of a standard load plate on a
200 mm × 200 mm specimen. $s'$ is the input to the floating-floor term of the
EN 12354-2 impact model covered in
[Predicting Sound Insulation (EN 12354)](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/). (ISO 16251-1 does not apply
here: its scope is limited to soft, locally-reacting floor coverings and
explicitly excludes floating floors.)

![Floating-floor natural frequency versus the resilient layer's dynamic stiffness per unit area for a light and a heavy floating floor, with a worked design point](https://docs.jmrp.io/phonometry/media/dynamic_stiffness.svg)

*The whole design problem in one chart: $f_0 = (1/2\pi)\sqrt{s'/m'}$, so the
natural frequency falls as the square root of the layer's dynamic stiffness
and rises as the square root of one over the slab's surface mass. Quartering
$s'$ halves $f_0$, and so does quadrupling the slab mass. A floating floor
only improves insulation well above $f_0$, which is why the design goal is a
soft layer under a heavy slab, and why the flat right-hand end of the curve
means that a stiffer layer costs less than it looks.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import materials

# The design curve for a light and a heavy floating floor (Formula 2).
s = np.logspace(np.log10(2.0), np.log10(100.0), 300)   # MN/m3
for m in (40.0, 120.0):
    plt.semilogx(s, materials.natural_frequency(s * 1e6, m), label=f"m' = {m:g} kg/m²")
plt.xlabel("Dynamic stiffness s' [MN/m³]"); plt.ylabel("Natural frequency f₀ [Hz]")
plt.legend(); plt.show()

# A measured determination draws the same curve with its own point marked;
# `floating_floor_resonance` and its arguments are the subject of section 2.
```

## 1. Dynamic stiffness and resonance

The dynamic stiffness per unit area is a dynamic force per area divided by the
resulting change in thickness (Formula 1): $s' = (F/S)/\Delta d$. The resiliently
supported floor is a resonator whose natural frequency (Formula 2) and, in the
laboratory arrangement, measured resonant frequency (Formula 3) are

$$
f_0 = \frac{1}{2\pi}\sqrt{\frac{s'}{m'}}, \qquad
f_\mathrm{r} = \frac{1}{2\pi}\sqrt{\frac{s'_\mathrm{t}}{m'_\mathrm{t}}},
$$

so the **apparent** dynamic stiffness follows from the resonance (Formula 4):

$$
s'_\mathrm{t} = 4\pi^2\,m'_\mathrm{t}\,f_\mathrm{r}^2 .
$$

![EN 29052-1 resonance rig in three panels: the three excitation arrangements of Figures 1 to 3, one on a rigid foundation with the load plate driven and measured, two on an isolated baseplate of at least 100 kg where both plates are measured and the exciter drives either the load plate or the baseplate; below, the specimen and load requirements with the plaster bed, the steel load plate and the petroleum-jelly fillet, and the mass-spring model whose response peak gives the resonant frequency](https://docs.jmrp.io/phonometry/media/diagram_dynamic_stiffness_rig.svg)

In the test arrangement the specimen lies between a base and a load plate
whose total mass per unit area, plate plus added load, is 200 kg/m² (8 kg on
the 0.04 m² specimen). That load reproduces the static preload of a typical
floating floor, about 2 kPa, and it is why the standard's scope stops at
loadings below 0.4 kPa and above 4 kPa. A vertical exciter drives the system,
an accelerometer picks up its response, and the fundamental vertical resonance
$f_\mathrm{r}$ of the plate-on-specimen system is read from the response peak;
Formula 4 turns it into $s'_\mathrm{t}$.

### 1.1 Getting $f_\mathrm{r}$

The library takes $f_\mathrm{r}$ as an input, and Clause 7 is how a laboratory produces
one. Three excitation signals are offered and declared **equivalent**:
sinusoidal, white noise and pulse. Sinusoidal is the reference method in case
of dispute; white-noise and pulse excitation are analysed as a frequency
response per ISO 7626-2 or by impact excitation. The three arrangements drawn
above differ in where the exciter sits and what is measured: on a rigid base
whose velocity is negligible against the load plate's, the load plate alone is
enough; on a baseplate of at least 100 kg carried on soft mounts, both plates
are measured. Whichever is used, the arrangement must permit vertical motion
only, without rotational components, and it is reported with the result.

The sinusoidal procedure is a sweep at **constant excitation force**. The catch
is that $f_\mathrm{r}$ often depends on that force, because a resilient layer is
non-linear: drive it harder and it softens, and the peak walks down in
frequency. So the standard does not ask for a resonance, it asks for the
resonance the material would have at vanishing amplitude:

1. Sweep at one force amplitude and read the peak.
2. Repeat at **at least three** force amplitudes inside the interval the
   expected stiffness selects: $0.2\ \text{N} \le F \le 0.8\ \text{N}$ for
   $s' > 50$ MN/m³, and $0.1\ \text{N} \le F \le 0.4\ \text{N}$ for
   $s' \le 50$ MN/m³.
3. Extrapolate the $(F, f_\mathrm{r})$ points linearly to zero force. **That
   intercept** is the $f_\mathrm{r}$ the library expects.

```python
import numpy as np

# `materials` is imported by the block above. Three sinusoidal sweeps inside
# the 0.1-0.4 N interval (this layer is well under 50 MN/m3), each giving its
# own peak: the layer softens as it is driven harder, so f_r walks down.
force = np.array([0.10, 0.25, 0.40])          # N
peak = np.array([25.6, 25.0, 24.4])           # Hz, read from the response

slope, intercept = np.polyfit(force, peak, 1)
print(round(float(intercept), 2))             # 26.0  Hz at F -> 0
s_t = materials.apparent_dynamic_stiffness(resonant_frequency_hz=intercept,
                                           total_mass_per_area_kg_m2=200.0)
print(round(s_t / 1e6, 3))                    # 5.337  MN/m3
# Taking the hardest-driven sweep at face value instead gives 4.701 MN/m3,
# 12 % low, and a floating-floor f0 about 5 % low with it.
```

One material defeats the peak-reading altogether. When the internal damping is
high the vertical vibration maximum is not pronounced, and the standard's
answer is to stop looking at the magnitude: locate the resonance from the
**phase shift** between the excitation and the vibration signal instead. That
phase is not a fallback reading of the same thing; it is a sharper one, and
watching a sweep run through $f_\mathrm{r}$ shows why.

**Video:** [Sweeping an EN 29052-1 rig through its resonance](https://docs.jmrp.io/phonometry/media/anim_dynamic_stiffness_sweep.webm): A sinusoidal sweep from 8 Hz to 60 Hz drives the 8 kg load plate on its resilient specimen while the response magnitude and phase are tracked. Below the 25 Hz resonance the plate moves in phase with the force; at resonance the amplitude peaks and the motion falls a quarter cycle behind, crossing minus 90 degrees; above it the plate moves against the force towards antiphase. The plate is watched stroboscopically at the drive frequency and its motion is drawn on a compressed amplitude scale, so what moves on screen is the phase relationship rather than the 25 Hz oscillation itself.

The magnitude peak is broad (it is what the loss factor makes of it) while
the phase runs through $-90°$ steeply and crosses it at $f_\mathrm{r}$ whatever the
damping. That is the whole reason the standard offers the phase reading for
damped materials, and it is worth having on any rig, because a peak that is
2 Hz wide is a peak that can be read 2 Hz wrong.

### 1.2 Preparing the specimen and the rig

The measured $f_\mathrm{r}$ is decided by the bedding and by the rig tolerances at
least as much as by the material, and both are normative.

- **Specimens.** At least three, each 200 mm × 200 mm (Clause 6). Their
  surfaces count as smooth only if the irregularities are under 3 mm.
- **Bedding.** Cover the specimen with a waterproof plastic foil about
  0.02 mm thick, apply a thin paste of plaster of Paris and water at least
  5 mm deep so that any unevenness is covered, and bed the load plate onto it
  **before the plaster sets**. A dry or partial contact carries the load on
  part of the specimen area, stiffens the reading and biases $f_\mathrm{r}$ upward.
- **Closed-cell materials.** Seal the joint between the specimen and the base
  around the perimeter with a fillet of petroleum jelly. An unsealed perimeter
  changes what the enclosed gas of section 2 can do.
- **Plates.** The load plate is steel, (200 ± 3) mm square, and both it and
  the base have profile irregularities under 0.5 mm and are stiff enough to
  avoid bending waves in the frequency range of interest.
- **The load is a budget, not a plate.** The total load on the specimen is
  8 kg ± 0.5 kg **including all measuring and excitation equipment**, so the
  accelerometer, the stinger and anything else resting on the plate count
  against it.

```python
from phonometry import materials

# Standard 8 kg load plate on the 0.04 m2 specimen -> m't = 200 kg/m2;
# the fundamental resonance is measured at 25 Hz.
s_t = materials.apparent_dynamic_stiffness(resonant_frequency_hz=25.0, total_mass_per_area_kg_m2=200.0)
print(round(s_t / 1e6, 3))                              # 4.935  MN/m3

# Installed on a 120 kg/m2 floating screed with s' = 10 MN/m3:
print(round(materials.natural_frequency(10e6, 120.0), 1))      # 45.9  Hz
```

That little oscillator is small enough to draw at true scale.
`plot_dynamic_stiffness_rig` puts the standard 200 mm specimen under the 8 kg
load plate with the exciter and accelerometer in place.

![To-scale section of the dynamic-stiffness rig: the dotted 200 mm resilient specimen, 20 mm thick, on the hatched rigid foundation, the grey 8 kg load plate on top with the accelerometer ball at its edge, and the exciter block above driving the plate through a red vertical arrow, the specimen side and thickness dimensioned](https://docs.jmrp.io/phonometry/media/dynamic_stiffness_rig_geometry.svg)

*The mass-spring system behind $s'$ at true scale: 20 mm of resilient layer
under the 8 kg plate is all it takes to reproduce the 2 kPa preload of a
floating floor.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import materials

# The standard rig: a 200 mm square specimen under the 8 kg load plate.
materials.plot_dynamic_stiffness_rig()
plt.show()
```

## 2. The enclosed-gas term and airflow resistivity

For an air-permeable material the enclosed pore air adds a parallel stiffness
from its isothermal compression (Formula 7):
$s'_\mathrm{a} = p_0/(d\,\varepsilon)$, with $p_0$ the atmospheric pressure, $d$ the
loaded thickness and $\varepsilon$ the porosity. The standard's worked NOTE
($p_0 = 0.1\ \text{MPa}$, $\varepsilon = 0.9$) is $s'_\mathrm{a} = 111/d$ MN/m³ for
$d$ in millimetres:

```python
from phonometry import materials

print(round(materials.enclosed_gas_stiffness(thickness_m=0.020, porosity=0.9) / 1e6, 2))
# 5.56  MN/m3   (the NOTE's 111/20 = 5.55 MN/m3)
```

That term is not a rounding correction. At 20 mm it is already larger than the
frame stiffness the rig measured, and below about 22 mm the pore air, not the
material, is the spring.

![Log-log plot of dynamic stiffness per unit area against loaded thickness from 5 to 60 millimetres: the frame stiffness is a horizontal line at 4.94 meganewtons per cubic metre, the enclosed-gas term falls as 111 over the thickness and crosses it near 22 millimetres, and their sum is the installed stiffness, with the worked determination marked at 20 millimetres and a right-hand axis giving the natural frequency of a 120 kilogram per square metre screed](https://docs.jmrp.io/phonometry/media/enclosed_gas_stiffness.svg)

*The inversion that decides whether a thin layer can ever be soft. The frame
stiffness $s'_\mathrm{t}$ is a property of the material and does not care how thick the
layer is; the enclosed-gas term $s'_\mathrm{a} = p_0/(d\varepsilon)$ does, and it grows
without limit as the layer thins. Below the crossing near 22 mm the air in the
pores is the stiffer of the two springs, so a 10 mm permeable layer cannot be
soft however soft its frame is: 11 MN/m³ of gas alone puts $f_0$ back above
50 Hz on a 120 kg/m² screed. The right-hand axis is the same $s'$ read as that
natural frequency.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `materials` is imported above. The clause 8.2 sum against loaded thickness,
# the frame term held at the worked determination's 4.94 MN/m3.
d_mm = np.logspace(np.log10(5.0), np.log10(60.0), 300)
s_gas = np.array([materials.enclosed_gas_stiffness(thickness_m=d * 1e-3,
                                                   porosity=0.9) / 1e6
                  for d in d_mm])
fig, ax = plt.subplots()
ax.loglog(d_mm, np.full_like(d_mm, 4.935), "--", label="s't, frame")
ax.loglog(d_mm, s_gas, "-.", label="s'a, enclosed gas")
ax.loglog(d_mm, 4.935 + s_gas, "-", label="s' installed")
ax.set_xlabel("Loaded thickness d [mm]")
ax.set_ylabel("Dynamic stiffness per unit area [MN/m³]")
ax.legend()
plt.show()
```

The dynamic stiffness of the *installed* material is then set by the lateral
airflow resistivity $r$ (clause 8.2): $s' = s'_\mathrm{t}$ for
$r \ge 100\ \text{kPa}\cdot\text{s/m}^2$, $s' = s'_\mathrm{t} + s'_\mathrm{a}$ for
$10 \le r < 100\ \text{kPa}\cdot\text{s/m}^2$, and for
$r < 10\ \text{kPa}\cdot\text{s/m}^2$ the method only resolves $s' = s'_\mathrm{t}$
when the gas term is negligible.

**Why lateral resistivity decides anything.** Under the load plate the layer is
compressed, and the pore air has two ways out: it can be squeezed sideways out
of the layer, or it can be compressed in place with the frame. It is a spring
in parallel with the frame only in the second case, and the lateral airflow
resistivity is exactly what decides which happens. That maps onto the three
branches. At **high** $r$ the air is trapped both in the 200 mm specimen and
under a full floor, so the $s'_\mathrm{t}$ the rig measured already contains it and
nothing is added. At **intermediate** $r$ it escapes from the small specimen
but not from a floor several metres across, so the standard computes $s'_\mathrm{a}$
and adds it back. At **low** $r$ it escapes from both: there is no gas spring
to add, but the method can no longer separate the two contributions either.
In that third case report $s' = s'_\mathrm{t}$ with the reservation, and state the
estimated error of disregarding $s'_\mathrm{a}$: the standard asks for exactly that.
Note also where $r$ comes from: it is the same viscous property ISO 9053
measures, but along the layer rather than through it, and here it is an input
rather than something the method determines. Take the porosity $\varepsilon$
for $s'_\mathrm{a}$ as the standard's 0.9 unless it has been measured.

**Mind the prefix.** $r$ is the quantity ISO 9053 calls $\sigma$ and reports in
Pa·s/m², while EN 29052-1 writes it $r$ and thresholds it in **kPa·s/m²**. The
library follows the standard and puts the unit in the argument's name,
`airflow_resistivity_kpa_s_m2`, the one argument of the EN 29052-1 functions
that is not plain SI, and it takes it by name only, so that the unit is on
the line that passes it. A mineral wool measured at 50 000 Pa·s/m² goes in as `50.0`,
not `50000.0`; convert an
[ISO 9053 result](https://docs.jmrp.io/phonometry/materials/absorbers/airflow-resistance/) with
`sigma / 1000`. Passing the Pa·s/m² number would land in the
$r \ge 100$ branch, which drops the enclosed-gas term: for the determination
below that turns $s' = 10.49$ MN/m³ into 4.93 MN/m³ and the design natural
frequency from 47.1 Hz to 32.3 Hz, with no warning, because the wrong branch is
a valid branch. A `ResilientLayer` (below) takes the same resistivity as
`airflow_resistivity_pa_s_m2`, in the Pa·s/m² every catalogue of the library
holds it in, and converts it itself.

`floating_floor_resonance` chains the whole determination:

```python
from phonometry import materials

res = materials.floating_floor_resonance(
    resonant_frequency_hz=25.0, total_mass_per_area_kg_m2=200.0,
    floor_mass_per_area_kg_m2=120.0,
    airflow_resistivity_kpa_s_m2=50.0,   # kPa.s/m2 (= 50000 Pa.s/m2 from ISO 9053)
    thickness_m=0.020, porosity=0.9,
)
print(round(res.dynamic_stiffness_n_m3 / 1e6, 2), round(res.natural_frequency, 1))
# 10.49 47.1

res.plot()   # the f0(s') design curve with this determination marked (needs matplotlib)
```

The `DynamicStiffnessResult` carries the apparent, enclosed-gas and installed
stiffnesses, the test resonance and the installed-floor natural frequency, and
its `.plot()` draws the $f_0(s')$ design curve.

### Test-report fiche

`DynamicStiffnessResult.report(path)` renders a one-page accredited
dynamic-stiffness test report (EN 29052-1:1992 = ISO 9052-1:1989): a metadata
header (specimen, the total mass per unit area $m'_\mathrm{t}$ used during the test, the
loaded thickness $d$ (in metres, shown in mm), test facility, climate), a compact metrics table (the
resonant frequency $f_\mathrm{r}$, the apparent stiffness $s'_\mathrm{t}$ of Formula 4, the
enclosed-gas term $s'_\mathrm{a}$ when it applies, the installed $s'$ of clause 8.2 and
the natural frequency $f_0$ of Formula 2) beside the $f_0(s')$ design curve, and
a boxed apparent dynamic stiffness $s'_\mathrm{t}$ with the installed $s'$ and the
resonance $f_\mathrm{r}$ alongside. Clause 9 rounds every stiffness to the nearest
MN/m³. It is a characterisation, so there is no pass/fail verdict;
`language="es"` renders the Spanish fiche. The fiche always embeds the
$f_0(s')$ design curve, so it needs both the report and plot extras
(`pip install "phonometry[report,plot]"`).

```python
from phonometry import ReportMetadata, materials

res = materials.floating_floor_resonance(
    resonant_frequency_hz=45.0, total_mass_per_area_kg_m2=200.0,
    floor_mass_per_area_kg_m2=110.0,
    airflow_resistivity_kpa_s_m2=50.0,   # kPa.s/m2 (= 50000 Pa.s/m2 from ISO 9053)
    thickness_m=0.020, porosity=0.9,
)
res.report(
    "dynamic_stiffness.pdf",
    metadata=ReportMetadata(
        specimen="20 mm mineral-wool resilient layer",
        mass_per_area=200.0, thickness_m=0.020,   # thickness d (20 mm)
        measurement_standard="EN 29052-1",
    ),
)   # one-page fiche (needs phonometry[report,plot])
```

**Report:** [EN 29052-1 dynamic-stiffness example report (PDF)](https://docs.jmrp.io/phonometry/media/en29052_dynamic_stiffness_example.pdf): One-page dynamic-stiffness fiche: a metadata header with the total mass per unit area and the loaded thickness, a metrics table of the resonant frequency, the apparent, enclosed-gas and installed dynamic stiffnesses and the natural frequency beside the f0(s') design curve, and the boxed apparent dynamic stiffness s't.

Dynamic-stiffness fiche (DynamicStiffnessResult.report): the resonance metrics and the f0(s') design curve.

### Published layers, when there is no declared value

Designing a floating floor starts from the manufacturer's $s'$, declared to
EN 29052-1 for that product. When there is none, fifteen measured layers are
published as `PUBLISHED_RESILIENT_LAYERS`, transcribed from Hopkins Table A3
(printed p. 610), whose caption states they were measured according to
ISO 9052-1. The column heading prints $s'$, which the book's own list of
symbols defines as the dynamic stiffness of the installed layer and keeps apart
from the apparent $s'_\mathrm{t}$, so every row holds `dynamic_stiffness_n_m3`
and its natural frequency needs nothing but the mass of the floor. Each layer
is a catalogue row like the rows of every other published table: it carries
the page it was read on, and the four rebond foams carry the second-level
attribution the printed cell gives them.

The key is `"<table>/<row>"`, as in every catalogue: the packaged table,
`hopkins-2007-table-a3`, and then which specimen the row is,
`<material>_<density>_<thickness>`, because four rock-wool rows and four
glass-wool rows differ only by those two numbers and the printed table
separates them by position under a name it prints once.

```python
from phonometry import materials

layer = materials.resilient_layer("hopkins-2007-table-a3/mineral_wool_rock_60_30")
print(layer.name, layer.density_kg_m3, layer.thickness_mm)   # Mineral wool, rock 60.0 30.0
print(layer.source)
# Hopkins (2007) Table A3, PDF page 637 (printed p. 610)
print(round(layer.dynamic_stiffness_n_m3 / 1e6, 1))          # 10.0 MN/m3, as printed
print(round(layer.natural_frequency(mass_per_area_kg_m2=120.0), 1))   # 45.9 Hz under a 120 kg/m2 screed

rebond = materials.PUBLISHED_RESILIENT_LAYERS["hopkins-2007-table-a3/rebond_foam_64_20"]
print(rebond.attributed_to["row"])                           # Hopkins and Hall (2006)
print(round(rebond.natural_frequency(mass_per_area_kg_m2=120.0), 1))  # 43.6
```

These are measured specimens and not declared product values: they are the
order of magnitude to reason with while a product is chosen, not an input to a
compliance calculation. The softest row in the table, 40 mm glass wool at
7 MN/m³, puts the same screed at 38.4 Hz, and the stiffest, 5 mm closed-cell
polyethylene foam at 115 MN/m³, at 155.8 Hz; that spread is the whole design
question.

**A layer that gives only $s'_\mathrm{t}$.** A test report to EN 29052-1 gives
the apparent stiffness $s'_\mathrm{t}$ of its specimen and the enclosed-gas
stiffness $s'_\mathrm{a}$, and it gives $s'$ only "if possible" (clause 9 e));
a sheet that quotes $s'_\mathrm{t}$ alone gives less than the report it came
from. Either way $s'_\mathrm{t}$ is not the $s'$ that Formula 2 takes: for an
air-permeable layer the enclosed gas adds to it, and Hopkins notes that it
often forms a significant percentage of $s'$ (printed p. 360). A
`ResilientLayer` built from such a source holds it in
`apparent_dynamic_stiffness_n_m3`, and its `natural_frequency` refuses to go on
until it is given the lateral airflow resistivity, in Pa·s/m² as ISO 9053
reports it, and, below 100 kPa·s/m², the enclosed-gas stiffness: the
$s'_\mathrm{a}$ the report states, or Formula 7 on the thickness under the
test load, which clause 9 b) has the report state as well and which is not the
nominal thickness a product sheet prints. With them it takes the clause 8.2
branch that resistivity picks:

```python
from phonometry import materials

report = materials.ResilientLayer(
    name="Example layer",
    source="Example Acoustics Ltd test report 26-014, p. 2",
    apparent_dynamic_stiffness_n_m3=6.0e6,
)
try:
    report.natural_frequency(mass_per_area_kg_m2=120.0)
except ValueError as refusal:
    print(refusal)
# 'Example layer' gives the apparent dynamic stiffness s't of a test specimen,
# 6 MN/m3, and not the dynamic stiffness s' of the installed layer [...]: pass
# airflow_resistivity_pa_s_m2 and, below 100 kPa.s/m2 (100000 Pa.s/m2),
# gas_stiffness_n_m3, the enclosed-gas stiffness s'a of Formula 7 [...]

# d = 30 mm under the test load, from the report (clause 9 b)); an s'a the
# report states (clause 9 e)) goes in as gas_stiffness_n_m3 the same way.
gas = materials.enclosed_gas_stiffness(thickness_m=0.030, porosity=0.9)   # 3.7 MN/m3
f0 = report.natural_frequency(
    mass_per_area_kg_m2=120.0,
    airflow_resistivity_pa_s_m2=50_000.0,   # 50 kPa.s/m2: Formula 6, s' = s't + s'a
    gas_stiffness_n_m3=gas,
)
print(round(f0, 1))                                              # 45.3 Hz
```

Read as if it were $s'$, the same 6 MN/m³ would have put the screed at
35.6 Hz, almost 10 Hz too low.

## 3. What the resonance method assumes, and where it bites

The evaluation treats the rig as a single-degree-of-freedom system: the load
plate moves as a rigid piston on a massless spring. That holds while the
specimen is light against the plate and its first internal resonance sits
well above $f_\mathrm{r}$; a heavy or very thick layer starts to act as a distributed
system and the simple Formula 4 reading degrades. Three practical pitfalls
follow from the preload:

* **$s'$ is a stiffness *at the standard preload*.** Resilient layers are
  visibly non-linear in static load: mineral wool stiffens as it compresses,
  some foams soften. The 200 kg/m² load plate fixes the operating point, so
  the tabulated $s'$ strictly describes floors near that surface mass.
  Designing a much heavier screed with the same $s'$ extrapolates beyond the
  measurement.
* **Drive small.** The tangent stiffness is defined for small dynamic
  strains; driving the plate hard pushes the layer into its non-linear range
  and shifts the apparent resonance downward. Keep the excitation at the
  lowest level that gives a clean peak.
* **Respect the contact.** The standard seats the load plate on a thin
  bonding layer (a plaster paste) so the full specimen area carries the
  load. A dry, uneven contact concentrates the force, stiffens the response
  locally and biases $f_\mathrm{r}$ upward.

### 3.1 Reading $s'$, and what it buys

The natural frequency that matters in the end is not the rig's $f_\mathrm{r}$ but the
installed floor's $f_0$ from Formula 2. Two questions follow, and the page
owes both an answer.

**Is 10.5 MN/m³ a good number?** Resilient layers used under screeds run from
a few MN/m³ for soft elastomeric products and low-density mineral wools up to
several tens for stiffer boards, so the worked determination sits in the
middle of the usable range. The floor under it is the enclosed-gas term: for
a 90 % porous layer it alone contributes about $111/d$ MN/m³ with $d$ in
millimetres, so a thin permeable layer cannot be soft whatever its frame does.

**What does a low $f_0$ buy?** The floating floor improves impact insulation
by $\Delta L = 30\lg(f/f_0)$ for sand-cement and calcium-sulfate screeds
(ISO 12354-2 Formula (C.1)), and by $40\lg(f/f_0)$ for asphalt and dry floors.
So the 47 Hz of the worked determination gives about 31 dB at 500 Hz and
nothing at all at and below $f_0$. Halving $f_0$ buys roughly 9 dB
across the whole band, which is why the entire method exists. The practical
target is to keep $f_0$ below the lowest band of interest.

![Two panels: on the left the load-plate response of the rig against frequency, peaking at 25 hertz for a small excitation and at 22 hertz with a lower peak when over-driven; on the right the improvement of impact insulation against frequency for two resilient layers, rising as thirty times the logarithm of frequency over the natural frequency from 47 hertz and from 32 hertz, with the ideal mass-spring isolation curve showing the amplification below the square root of two times the natural frequency shaded in red](https://docs.jmrp.io/phonometry/media/floating_floor_transmissibility.svg)

*Left: the peak the operator reads off the rig, and what over-driving does to
it: the resonance walks down in frequency and flattens, which is the whole
reason for the extrapolation of section 1.1. Right: what the installed floor
does with the result. Nothing is gained below $\sqrt{2}\,f_0$; the shaded
region is where an undamped mass-spring floor would be worse than no floating
floor at all, and the ISO 12354-2 law truncates that to zero rather than
predicting the ideal peak, because a real screed on a real layer is damped.
Halving $s'$ moves $f_0$ down by $\sqrt{2}$ and lifts the whole curve by about
5 dB: 30.8 dB against 35.6 dB at 500 Hz for the two layers drawn.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `materials` is imported above. The ISO 12354-2 law in closed form for the
# worked determination and for a layer half as stiff; the library evaluates
# the same law, with its branches, in floating_floor_improvement_spectrum
# (see the resilient-layer prediction guide).
bands = np.array([50, 63, 80, 100, 125, 160, 200, 250, 315, 400, 500,
                  630, 800, 1000, 1250, 1600, 2000, 2500, 3150], float)
fig, ax = plt.subplots()
for stiffness in (10.49e6, 5.0e6):
    f0 = float(materials.natural_frequency(stiffness, 120.0))
    delta_l = np.maximum(30.0 * np.log10(bands / f0), 0.0)   # Formula (C.1)
    ax.semilogx(bands, delta_l, "o-", label=f"f0 = {f0:.0f} Hz")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Improvement of impact insulation [dB]")
ax.legend()
plt.show()
```

How much improvement that actually buys band by band, and what it becomes as a
weighted single number, is
[Predicting Resilient-Layer Performance](https://docs.jmrp.io/phonometry/buildings/design/resilient-layers/).

## What this guide covers

- **Covered.** EN 29052-1:1992 (identical to ISO 9052-1:1989) for materials under floating
  floors: the dynamic stiffness per unit area of Formula 1, the resonance
  relations of Formulae 2-4 (`apparent_dynamic_stiffness`, `natural_frequency`),
  the enclosed-gas term of Formula 7 (`enclosed_gas_stiffness`), and the clause
  8.2 airflow-resistivity regimes of Formulae 5-6
  (`installed_dynamic_stiffness`), chained end to end by
  `floating_floor_resonance`. `DynamicStiffnessResult.report` renders the clause
  9 test-report fiche. `ResilientLayer.natural_frequency` applies Formula 2 to a
  published or user-built layer, through clause 8.2 when the layer gives only
  $s'_\mathrm{t}$.

- **Not covered.** Clause 7's measurement procedure, extracting the resonant frequency $f_\mathrm{r}$ from
  the raw excitation-response signal by sinusoidal, white-noise or pulse
  methods, is not implemented: pass an already-extrapolated $f_\mathrm{r}$, obtained as
  section 1.1 describes (the extrapolation itself is a straight-line fit, which
  section 1.1 shows). The lateral airflow resistivity $r$ of clause 8.2 is
  likewise taken as an input rather than measured; ISO 9053's static and
  alternating methods are implemented separately, in
  `materials.absorbers.airflow_resistance`, and they report $\sigma$ in Pa·s/m²,
  the unit `ResilientLayer.natural_frequency` takes, while
  `airflow_resistivity_kpa_s_m2` is in kPa·s/m². Clause 6's
  specimen-selection requirement (at least three 200 mm × 200 mm specimens) is
  not enforced, and neither is the Clause 9 report content: the fiche below
  carries the excitation arrangement and the signal type only if they are
  supplied in the metadata.

## See also

- [Predicting Resilient-Layer Performance](https://docs.jmrp.io/phonometry/buildings/design/resilient-layers/):
  what the design side does with $s'$, from the mass-spring resonance to the
  improvement laws above it and their weighted single number.
- [Predicting Sound Insulation (EN 12354)](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/):
  the floating-floor term this measurement feeds.
- [Airflow Resistance](https://docs.jmrp.io/phonometry/materials/absorbers/airflow-resistance/): the
  ISO 9053 determination of the lateral resistivity $r$ that clause 8.2 needs,
  reported there as $\sigma$ in Pa·s/m².
- [Resilient layers overview](https://docs.jmrp.io/phonometry/materials/resilient/): where this
  measurement sits among the materials guides.
- API reference: [`materials.resilient.dynamic_stiffness`](https://docs.jmrp.io/phonometry/reference/api/materials/dynamic-stiffness/).
- Theory: [Point mobilities and radiation efficiency](https://docs.jmrp.io/phonometry/reference/theory/vibration/#point-mobilities-and-radiation-efficiency-cremer-5-hopkins-29): the mass-spring resonance the EN 29052-1 rig measures, seen as a mobility.

## References

- **International Organization for Standardization. (1989).** [*Acoustics — Determination of dynamic stiffness — Part 1: Materials used under floating floors in dwellings*](https://www.iso.org/standard/16620.html) (EN 29052-1:1992 (ISO 9052-1:1989)).
  EN 29052-1:1992 is the identical European adoption of ISO 9052-1:1989 and is the designation this page uses throughout; the ISO URL is the citable one. The method implemented here: the dynamic stiffness per unit area (Formula 1), the resonance relations (Formulae 2-4), the enclosed-gas term (Formula 7, clause 8.2 NOTE s'a = 111/d MN/m³) and the airflow-resistivity regimes (Formulae 5-6). Conformance is anchored on the standard's own numeric NOTE plus hand-computed closed-form values of the resonance relations.
- **Vigran, T. E. (2008).** *Building acoustics*. CRC Press. https://doi.org/10.1201/9781482266016
  Floating-floor design and the role of the resilient layer's dynamic stiffness in the impact-sound improvement. ISBN 978-0-415-42853-8.