# Impedance Tube

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/materials/absorbers/impedance-tube/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/materials/absorbers/impedance-tube/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-28
Updated: 2026-11-01T10:32:36Z
Standards: ISO 10534-1:1996; ISO 10534-2:1998; ASTM E2611-19
Verified: 2 conformance checks (ISO 10534-1:1996; ISO 10534-2:1998) https://docs.jmrp.io/phonometry/reference/conformance/#materials-absorption-airflow-impedance
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Normal-incidence absorption and impedance in the tube: ISO 10534-1 standing wave, ISO 10534-2 two microphones and ASTM E2611 transmission loss.

---

The impedance tube is the materials laboratory shrunk to a bench: a rigid duct
a few centimetres across in which a loudspeaker drives a single plane wave
against a small sample, and everything the sample does to that wave is read
back from microphones in the tube wall. Because there is one wave and one
angle, the tube recovers what a reverberation room cannot: the **complex**
reflection factor and surface impedance at normal incidence, magnitude and
phase, from a specimen the size of a coffee-cup lid. Three standards share
the hardware and differ in method, and the library keeps their helpers
separate and never mixes them: the **standing-wave-ratio** method of
ISO 10534-1, the two-microphone **transfer-function** method of ISO 10534-2,
and the four-microphone **transfer-matrix** method of ASTM E2611 that adds
the transmission loss. The closing section runs the whole instrument, sample
included, inside the [FDTD solver](https://docs.jmrp.io/phonometry/simulation/fdtd-simulation/) and
recovers the analytic answer through the same reduction chains.

![ISO 10534-2 two-microphone impedance tube: a loudspeaker radiating a plane wave down the tube, two microphones flush in the wall at spacing s and distance x1 from the specimen face, the test specimen against a rigid backing, and the incident and reflected waves](https://docs.jmrp.io/phonometry/media/diagram_impedance_tube.svg)

## 1. The working frequency range

Everything the tube reports (ISO 10534-2, Clause 4) assumes the field inside is a single plane wave, and the geometry sets
both ends of the usable band. Above the cut-on of the first cross-sectional
mode the field stops being planar: a circular tube of diameter $d$ needs
$f\,d < 0.58\,c_0$ (Eq. (2); $f\,d < 0.50\,c_0$ for a rectangular tube,
Eq. (3)). The microphone spacing $s$ must also stay clear of the
half-wavelength singularity of the transfer-function method,
$f\,s < 0.45\,c_0$ (Eq. (4)). At the low end the opposite problem appears: a
spacing much shorter than the wavelength leaves almost no phase difference
between the microphones to measure, so the Clause 4.2 guideline keeps the
spacing above 5 % of the wavelength:

$$
\frac{c_0}{20\,s} \;<\; f \;<\;
\min\!\left(0.58\,\frac{c_0}{d},\ 0.45\,\frac{c_0}{s}\right).
$$

No single tube covers the building-acoustics range. A 100 mm tube with a
100 mm spacing works from roughly 170 Hz to 1.5 kHz; reaching the 5 kHz bands
takes a small tube (29 mm) with a close spacing, which in turn cannot see the
low bands. Laboratories therefore pair a large and a small tube (or one tube
with two spacings) and splice the spectra; the two must agree in the overlap
bands, and a mismatch there points at the sample cut or mounting, not at the
physics.

```python
from phonometry import materials

# A 100 mm tube with 100 mm spacing, and a 29 mm tube with 20 mm spacing.
f_l, f_u = materials.plane_wave_frequency_range(0.100, 343.2, diameter_m=0.100)
print(round(f_l, 1), round(f_u, 1))     # 171.6 1544.4
f_l, f_u = materials.plane_wave_frequency_range(0.020, 343.2, diameter_m=0.029)
print(round(f_l, 1), round(f_u, 1))     # 858.0 6864.0
```

![Horizontal bars on a shared logarithmic frequency axis from 100 Hz to 8 kHz with the one-third-octave grid marked: a 100 mm bore with 100 mm and 50 mm microphone spacings, a 29 mm bore with 20 mm spacing, and the same 100 mm bore under the ASTM E2611 limits, each bar labelled with the limit that binds it at either end, and the overlap between the large and the small tube hatched](https://docs.jmrp.io/phonometry/media/tube_working_ranges.svg)

*Which tube sees which bands. Each bar is a geometry, and each end is labelled
with the constraint that binds it: the low end is always the
$c_0/(20 s)$ phase-resolution floor, while the top end is the cut-on
$0.58\,c_0/d$ for a wide-spaced tube and the spacing singularity
$0.45\,c_0/s$ once the microphones are far apart. The 100 mm tube with 100 mm
spacing covers the 200 Hz to 1250 Hz one-third-octave bands and the 29 mm tube
with 20 mm spacing the 1 kHz to 5 kHz bands, so the pair splices in the
1 kHz to 1.25 kHz overlap, and even together they do not reach the 100 Hz,
125 Hz and 160 Hz bands, which is why low-frequency absorption data come from
the reverberation room and not from a tube. The ASTM bar is the same hardware
under E2611's constants: wider at the bottom (a 1 % of wavelength floor
instead of 5 %) and narrower at the top (a $0.40\,c$ spacing bound instead of
$0.45\,c$).*

**Show the code for this figure**

```python
for spacing, diameter_m in ((0.100, 0.100), (0.050, 0.100), (0.020, 0.029)):
    iso = materials.plane_wave_frequency_range(spacing, 343.2, diameter_m=diameter_m)
    astm = materials.plane_wave_frequency_range_astm_e2611(spacing, 343.2, diameter_m=diameter_m)
    print(f"{diameter_m * 1e3:.0f} mm bore, s = {spacing * 1e3:.0f} mm:",
          f"ISO {iso[0]:.0f}-{iso[1]:.0f} Hz, ASTM {astm[0]:.0f}-{astm[1]:.0f} Hz")
```

Those limits are easier to see on the hardware itself.
`plot_impedance_tube_geometry` draws a tube to scale with its plane-wave
band worked out, and a measured `two_microphone_impedance` result that was
given its geometry (`spacing_m`, `x1`, `diameter_m`) redraws its own setup with
`result.plot_geometry()`.

![To-scale side view of a 100 mm ISO 10534-2 impedance tube: the loudspeaker at the left end, microphones 1 and 2 flush in the wall at s = 50 mm spacing with microphone 1 at x1 = 150 mm from the specimen face, the specimen against the rigid backing at the right, the circular cross-section beside the tube and the plane-wave working range of 343 to 1991 Hz that this geometry sets](https://docs.jmrp.io/phonometry/media/impedance_tube_geometry.svg)

*Everything the working-range inequalities talk about, in one to-scale side
view: the 100 mm bore sets the 1991 Hz top end, the 50 mm spacing sets the
343 Hz bottom end, and the microphones sit at $s$ = 50 mm with the farther
one $x_1$ = 150 mm from the specimen face.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import materials

materials.plot_impedance_tube_geometry(spacing_m=0.05, x1=0.15, diameter_m=0.10)
plt.show()

# A measured result that retains its geometry draws its own tube:
#   res = materials.two_microphone_impedance(
#       h12, frequency=f, spacing_m=0.05, x1=0.15, diameter_m=0.10, ...)
#   res.plot_geometry()
```

### 1.1 Where the microphones may sit

The working range is set by $d$ and $s$; *where along the tube* the pair goes
is a separate set of constraints, and Clause 4.3 fixes both ends of it.

**Away from the source.** The loudspeaker radiates cross-modes as well as the
plane wave. Below the first cut-on they die out within about three tube
diameters, so the nearest microphone is recommended to be at least three
diameters from the source and shall in any case be no closer than one: 300 mm
and 100 mm respectively on the 100 mm tube of the figure above.

**Away from the specimen.** The specimen distorts the field near its face too,
and the minimum depends on what the specimen looks like: half a diameter for a
*non-structured* sample, one diameter for a *semi-laterally structured* one,
and two diameters for a *strongly asymmetrical* one. On a 100 mm tube that is
50 mm, 100 mm and 200 mm, so the $x_1$ = 150 mm of the figure above is
comfortable for a plain porous sample, adequate for a perforated facing and
too close for a strongly structured specimen such as a resonator array. Nothing
enforces this: `reflection_factor` only rejects $x_1 \le 0$, so an $x_1$ chosen
by eye can sit inside the evanescent near field of a perforated sample and
still return a perfectly plausible-looking spectrum.

**How well the distances must be known.** Fixed microphone positions to
±0.2 mm or better and traversing ones to ±0.5 mm (Clause 4.5); the reference
plane's position relative to microphone 1 reported to ±0.5 mm (Clause 7.1);
and the microphone diameter under 20 % of the spacing, and small against
$c_0/f_\mathrm{u}$, so the capsule averages a negligible piece of the wave
(Clause 4.4). The reference plane, $x = 0$, is normally the specimen surface,
but a profiled or laterally structured specimen has its reference plane placed
some distance *in front* of it, and $x_1$ is measured to that plane, not to
the sample holder.

The same helper covers square and rectangular tubes: pass `shape="square"` or
`shape="rectangular"` and the Eq. (3) factor replaces the circular one, with
$d$ the maximum side length. The four-microphone branch keeps its own limits
in `plane_wave_frequency_range_astm_e2611`: ASTM E2611 retains the unrounded
circular constant ($f\,d < 0.586\,c$, 6.2.4.1), the same rectangular
$f\,d < 0.500\,c$ (6.2.5), a slightly stricter spacing bound
$f\,s < 0.40\,c$ (6.5.4) and a laxer low end at 1 % of the wavelength
(6.2.3). Passing `diameter_m=` (and `shape=`) to `two_microphone_impedance`,
`wave_decomposition` or the `transfer_matrix_*` solvers turns the matching
check into an advisory warning, and for the Annex A attenuation estimate of a
rectangular tube `hydraulic_diameter(width_m, height_m)` supplies the $4A/P$
diameter that `tube_attenuation_constant` expects.

The whole tube, sample included, can also be simulated: section 5 runs this
exact measurement virtually inside the FDTD solver and recovers the analytic
absorption of the modelled sample through the same reduction chain.

## 2. Standing-wave-ratio method (ISO 10534-1)

![ISO 10534-1 standing-wave apparatus in side view: a loudspeaker sealed to the left end driven with one pure tone at a time through a narrowband analyser, a probe microphone on a graduated carriage running along the tube axis, the test specimen against the rigid backing at the right with its face marked x = 0, the standing-wave envelope drawn inside the tube with its maxima decaying away from the specimen, the level difference between the first maximum and the first minimum, and the first minimum dimensioned from the specimen face](https://docs.jmrp.io/phonometry/media/diagram_standing_wave_tube.svg)

A probe traverses the standing wave
and reads the level difference $\Delta L = L_\text{max} - L_\text{min}$ between a
pressure maximum and the adjacent minimum. The standing-wave ratio (written
$s$ in ISO 10534-1, the same letter Part 2 uses for the microphone spacing of
section 1; the two never appear in the same equation, and the code keeps them
apart as `swr` and `spacing_m`) follows in closed form together with the
reflection magnitude and the absorption:

$$
s = 10^{\Delta L/20}, \qquad |r| = \frac{s-1}{s+1}, \qquad
\alpha = 1 - |r|^2.
$$

![ISO 10534-1 standing-wave-ratio method: the absorption coefficient and the reflection factor magnitude as functions of the standing-wave level difference, showing that a 9.54 dB difference corresponds to a standing-wave ratio of 3, a reflection magnitude of 0.5 and an absorption of 0.75](https://docs.jmrp.io/phonometry/media/impedance_tube.svg)

*A small level difference means a near-perfect absorber; a level difference of
9.54 dB gives $s = 3$, $|r| = 0.5$ and $\alpha = 0.75$.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import materials

level_diff = np.linspace(0.5, 40.0, 300)    # L_max - L_min [dB]
swr = materials.standing_wave_ratio_from_level(level_diff)
fig, ax = plt.subplots()
ax.plot(level_diff, materials.standing_wave_absorption(swr),
        label=r"Absorption coefficient $\alpha$")
ax.plot(level_diff, materials.standing_wave_reflection_magnitude(swr), "--",
        label="Reflection factor magnitude |r|")
ax.set_xlabel(r"Standing-wave level difference $L_\mathrm{max} - L_\mathrm{min}$ [dB]")
ax.set_ylabel(r"$\alpha$, $|r|$")
ax.legend()
plt.show()
```

```python
from phonometry import materials

s = float(materials.standing_wave_ratio_from_level(9.542))   # level difference [dB] -> SWR
print(round(s, 2))                                  # 3.0
print(round(float(materials.standing_wave_absorption(s)), 2)) # 0.75
```

The ratio method predates the FFT analyser and survives because it is
self-contained. The apparatus is a **probe microphone** on a graduated
carriage: a thin tube sliding along the axis, sampling the interior field
point by point while the loudspeaker holds a single pure tone. At each
frequency the operator (or the stepper motor) locates one pressure maximum
and the adjacent minimum, reads the level difference, and moves on to the
next tone. Slow, but there is nothing to calibrate against anything else: one
microphone measures both levels, so its sensitivity cancels exactly, and
there is no inter-channel phase mismatch because there is only one channel.
That is why the standing-wave method remains the arbitration method when two
transfer-function tubes disagree.

The closed forms above use only the level *difference*; the *positions* of
the minima carry the rest of the information. With $x$ measured from the
sample face towards the source, the interior field of a wave with reflection
factor $r = |r|\,\mathrm{e}^{j\Phi}$ is

$$
p(x) = A\left(\mathrm{e}^{jkx} + |r|\,\mathrm{e}^{j\Phi}\mathrm{e}^{-jkx}\right), \qquad
|p|^2 = A^2\left(1 + |r|^2 + 2|r|\cos(2kx - \Phi)\right),
$$

so pressure minima sit where the cosine is $-1$, at

$$
2k\,x_{\min,n} - \Phi = (2n - 1)\,\pi, \qquad
\Phi = \frac{4\pi\,x_{\min,1}}{\lambda} - \pi ,
$$

with $x_{\min,1}$ the minimum nearest the sample. A minimum a quarter
wavelength from the face means $\Phi = 0$ (a hard-backed sample at
resonance); a minimum right at the face means $\Phi = -\pi$ (a rigid wall).
Magnitude from the ratio, phase from the position: together they give the
same complex $r$, and hence the same normalised impedance
$Z/\rho c_0 = (1+r)/(1-r)$, that the transfer-function method of section 3
computes from $H_{12}$ in one shot.

![The standing-wave envelope level in decibels along the first metre of a 100 mm tube at 500 Hz for three terminations: a rigid wall whose minima plunge off the axis with the first at the specimen face, the worked sample of reflection magnitude 0.5 whose first minimum sits 12 centimetres out at minus 6 decibels, and a near-anechoic termination that is almost flat. A dotted copy of the 0.5 case carries the ISO 10534-2 tube attenuation, and the levels of its first three minima are annotated](https://docs.jmrp.io/phonometry/media/standing_wave_envelope.svg)

*What the carriage actually traverses, drawn as the level the analyser shows
at 500 Hz in a 100 mm tube. The rigid wall ($|r| = 1$) has its minima on zero
pressure and the first of them at the face, $\Phi = -\pi$; the worked sample
($|r| = 0.5$) reads $\Delta L$ = 9.54 dB between the maximum and the adjacent
minimum, the first of them at $x_{\min,1}$ = 12 cm, and the
quarter-wavelength ruler converts that distance into $\Phi = -54.1°$; the
near-anechoic case ($|r| = 0.1$) modulates by only 1.74 dB, which is why the
method loses precision exactly where an absorber is good. The dotted curve is
the same $|r| = 0.5$ sample with the Eq. (A.18) tube attenuation: the further
from the face, the more the reflected wave has decayed, so the notches fill
in: the first three minima read −5.99, −5.92 and −5.85 dB. That drift is
small here because Eq. (A.18) is a lower bound; ISO 10534-1's approximate
extrapolation (Annex A.2.1.4) is offered while the first-to-second minimum
difference stays under 2 dB, and above that the attenuation has to be measured
on the empty tube. Either way it is why the operator reads the minimum
*nearest* the sample.*

**Show the code for this figure**

```python
# The interior field of section 2, for three reflection factors.
c0 = 343.2
x = np.linspace(0.0, 1.0, 800)
k = 2 * np.pi * 500.0 / c0
for magnitude, phi in ((1.0, -np.pi), (0.5, np.radians(-54.1)), (0.1, 0.0)):
    envelope = np.sqrt(1 + magnitude**2 + 2 * magnitude * np.cos(2 * k * x - phi))
    print(round(float(envelope.min()), 3), round(float(envelope.max()), 3))

# The attenuated variant uses the Eq. (A.18) lower-bound constant.
print(round(float(materials.tube_attenuation_constant(500.0, c0, 0.10)), 4))
```

Magnitude and position are the two halves of the reading, and the library
takes them together: `standing_wave_reflection(swr, x_min1, wavelength=lam)`
returns the complex $r$ (Eqs. (17)-(23)) and
`standing_wave_normalized_impedance` the ratio $Z/\rho c_0$ (Eqs. (24)-(26)).
Both accept arrays, so a stepper-motor traverse that logs $(\Delta L,
x_{\min,1})$ per tone reduces to two calls:

```python
import numpy as np
from phonometry import materials

# A three-tone traverse: the level difference and the first-minimum distance
# read at each frequency, which is all the method produces.
f = np.array([500.0, 1000.0, 2000.0])
c0 = 343.2
level_difference = np.array([9.542, 6.021, 3.522])   # L_max - L_min [dB]
x_min1 = np.array([0.120, 0.061, 0.030])             # first minimum [m]

swr = materials.standing_wave_ratio_from_level(level_difference)
lam = c0 / f
r = materials.standing_wave_reflection(swr, x_min1, wavelength=lam)
z = materials.standing_wave_normalized_impedance(swr, x_min1, wavelength=lam)
print(np.round(np.abs(r), 2))                  # [0.5  0.33 0.2 ]
print(np.round(np.degrees(np.angle(r)), 1))    # [-54.1 -52.  -54.1]
print(np.round(z, 2))                          # Z / rho c0
```

Two practical cautions from the standard's own text. The minima far from the
sample are shallower than the theory above says, because the travelling waves
decay along the tube (viscous and thermal losses at the wall); ISO 10534-1
has the operator read the minimum **nearest** the sample and, for precision
work, extrapolate the minimum levels to the sample face. And the method
leans on the purity of the tone: any harmonic distortion from a hard-driven
loudspeaker puts energy at frequencies whose minima sit elsewhere, partially
filling the notch being measured, so the analyser must be narrowband around
the drive frequency rather than a broadband level meter.

## 3. Transfer-function method (ISO 10534-2)

Two fixed microphones measure the
complex transfer function $H_{12}$; from it the reflection factor at the sample
face, the absorption and the normalised surface impedance follow (Eqs. (17)–(19)):

$$
r = \frac{H_{12} - H_\mathrm{I}}{H_\mathrm{R} - H_{12}}\,\mathrm{e}^{\,2 j k_0 x_1}, \qquad
\alpha = 1 - |r|^2, \qquad \frac{Z}{\rho c_0} = \frac{1+r}{1-r},
$$

with $H_\mathrm{I} = \mathrm{e}^{-j k_0 s}$, $H_\mathrm{R} = \mathrm{e}^{+j k_0 s}$, microphone spacing $s$ (the
Part 2 meaning of the letter again) and $x_1$ the distance from the reference
plane to the farther microphone.

**What an error in $x_1$ costs, and what it does not.** $x_1$ enters only
through $\mathrm{e}^{\,2 j k_0 x_1}$, a pure phase rotation. It therefore leaves
$|r|$ (and hence the absorption spectrum) completely untouched, while
rotating the real and imaginary parts of the surface impedance. At 1.5 kHz in
air a 2 mm error in $x_1$ rotates the reflection phase by about 6°, enough to
move a flow resistivity fitted from that impedance noticeably. The practical
consequences are two: measure $x_1$ to the *reference plane* (the specimen
face, or the plane in front of a profiled specimen) rather than to the sample
holder, since a specimen that does not sit where it was meant to moves $x_1$
with it; and read a healthy-looking $\alpha$ beside an implausible impedance
(a negative real part, say) as an $x_1$ or a mismatch fault, not as a material
result.

**Video:** [Standing wave in the impedance tube (ISO 10534-2)](https://docs.jmrp.io/phonometry/media/anim_standing_wave_tube.webm): The incident and reflected waves travel inside a drawn impedance tube and their sum forms the standing-wave envelope; a rigid termination with deep envelope nodes is compared with a porous sample with shallow ones, sampled by the two flush wall microphones.

```python
import numpy as np
from phonometry import materials

f = np.array([500.0, 1000.0, 1800.0])
x1, spacing, c0 = 0.12, 0.03, 343.2
k0 = materials.tube_wavenumber(f, c0)

# A measured transfer function H12 (here synthesised from r = 0.3 - 0.4j)
target = 0.3 - 0.4j
x2 = x1 - spacing
h12 = (np.exp(1j*k0*x2) + target*np.exp(-1j*k0*x2)) / \
      (np.exp(1j*k0*x1) + target*np.exp(-1j*k0*x1))

r = materials.reflection_factor(h12, spacing_m=spacing, x1=x1, wavenumber=k0)
print(np.round(materials.absorption_from_reflection(r), 3))     # [0.75 0.75 0.75]
print(np.round(materials.normalized_surface_impedance(r), 2))   # Z / rho c0
# [1.15-1.23j 1.15-1.23j 1.15-1.23j]
print(np.round(materials.normalized_surface_admittance(r), 2))  # its reciprocal,
# [0.41+0.43j 0.41+0.43j 0.41+0.43j]     what an impedance boundary condition wants
```

The high-level `two_microphone_impedance` wraps this chain and returns an
`ImpedanceTubeResult` with absorption, reflection factor, surface impedance and
normalised impedance, applying the plane-wave frequency-range check and optional
tube attenuation. Its `.plot()` draws the absorption spectrum
$\alpha(f)$ with the reflection-factor magnitude $|r|$ overlaid, and
`normalized_surface_admittance(r)` gives the reciprocal quantity that a
locally-reacting boundary condition (an FDTD or BEM wall, the library's own
solver) consumes.

### 3.1 Correcting the channel mismatch (Clause 7.5)

A channel is a microphone plus its preamplifier plus its analyser input, and no
two are identical. ISO 10534-2 Clause 7.5 does not recommend correcting for
that, it **requires** it: "one of the following procedures … shall be used".
Annex E.1.2 is blunter still (with two microphones the phase mismatch "is
unavoidable and shall be compensated for") and E.1.3 adds that the amplitudes
should be within 0.3 dB of each other to begin with. The correction is a
complex division applied exactly where $|r|$ is small and the phase of
$H_{12}$ carries the whole answer, which is why the symptom of skipping it is
frequency-dependent wander rather than an offset: the snippet below leaves a
0.5 dB / 1° mismatch uncorrected on a specimen whose true absorption is 0.75
and gets 0.73, 0.78 and 0.72 in three neighbouring bands. On a near-perfect
absorber the same mismatch pushes the spectrum against the $\alpha = 1$
ceiling, which is where the classic uncorrected-tube signature (an absorption
just above 1 or just below 0) comes from.

Both permitted procedures use the same measurement, made twice:

1. Place an absorptive specimen in the tube and measure $H_{12}^{I}$ in the
   standard configuration.
2. **Physically interchange the two microphone cartridges**, so that A takes
   the exact position B occupied and vice versa, *without* moving the cables
   on the preamplifier or the analyser. Measure $H_{12}^{II}$.
3. Form $H_\mathrm{c} = \sqrt{H_{12}^{I}/H_{12}^{II}}$ (Eq. (10)) and divide the working
   transfer function by it.

The difference between the two procedures is only how often step 2 is done.
Clause 7.5.1 repeats the swap for *every* specimen, which suits a small number
of samples; Clause 7.5.2 determines $H_\mathrm{c}$ once against a calibration specimen
and keeps it for the whole series, which suits a production run, after which
the microphones must stay where they are. The one-microphone technique of
Annex B needs no correction at all, because there is only one channel: it buys
that with measurement time, and it is the same argument that makes the
standing-wave method of section 2 the arbitration method.

```python
# A channel pair mismatched by 0.5 dB and 1 degree, and its removal. The two
# configurations differ by exactly that factor, which is what Eq. (10) recovers.
mismatch = 10 ** (0.5 / 20) * np.exp(1j * np.radians(1.0))
h12_i = h12 * mismatch            # standard configuration
h12_ii = h12 / mismatch           # microphones physically interchanged

hc = materials.microphone_calibration_factor(h12_i, h12_ii)
print(round(float(np.abs(hc[0])), 4), round(float(np.degrees(np.angle(hc[0]))), 2))
# 1.0593 1.0 -- the mismatch itself, recovered
h12_corrected = materials.apply_microphone_calibration(h12_i, hc)
print(float(np.abs(h12_corrected - h12).max()) < 1e-12)   # True

# What the uncorrected data would have claimed, on a sample of alpha = 0.75:
bad = materials.reflection_factor(h12_i, spacing_m=spacing, x1=x1, wavenumber=k0)
print(np.round(materials.absorption_from_reflection(bad), 3))   # [0.732 0.775 0.718]
```

### 3.2 The rest of the instrument

The reduction chain above is a few lines; the conditions that make its inputs
trustworthy are most of ISO 10534-2. In the order they matter:

- **The air, measured rather than assumed (Clause 7.2).** $c_0$ and $\rho c_0$
  are not constants of the method, they are readings. The tube air temperature
  must be measured and held to ±1 K with a transducer accurate to ±0.5 K, and
  the atmospheric pressure to ±0.5 kPa (Clause 4.12); Eq. (5) turns the first
  into $c_0$ and Eq. (7) the pair into $\rho$. The library exposes both:
  `speed_of_sound_iso10534(temperature_c=...)` and
  `air_density_iso10534(temperature_c=..., static_pressure_kpa=...)`. The
  temperature is in degrees Celsius, like every other temperature in the
  library, and the pressure in kilopascals, as Clause 4.12 states it. Both
  equations are written in kelvin, and the conversion happens inside, so the
  printed 293 K stays literal against the page. The fiche snippet below
  feeds them straight into `two_microphone_impedance` instead of literals.
- **Excitation (Clause 4.10, 7.3).** A stationary signal with a flat spectral
  density over the range of interest: random, pseudo-random, periodic
  pseudo-random or chirp. The level must sit at least 10 dB above the
  background at *every* frequency of interest, and any frequency whose response
  is 60 dB below the maximum is rejected outright. The number of spectral
  averages follows from the accuracy wanted on $H_{12}$; a bandwidth-time
  product of 50 to 100 is the usual target (Annex E.2), and the record must be
  much longer than $2x_1/c_0$ or time aliasing corrupts it (Eq. (E.1)).
- **Warm-up (Clause 5).** At least 10 minutes of loudspeaker operation before
  the first measurement, so the tube air temperature has stopped drifting.
- **The source end (Clauses 4.9, 4.11).** The loudspeaker membrane covers at
  least two thirds of the tube cross-section, sits in an insulating box against
  airborne flanking to the microphones, and is elastically isolated from the
  tube: structure-borne excitation of the tube wall is a classic mimic of
  absorption. At least 200 mm of effective absorbent lining near the
  loudspeaker damps the air-column resonances.
- **The specimen end (Clause 4.7).** The back plate is rigid and tightly fixed,
  a metal plate of at least 20 mm being recommended, because it is the rigid
  termination most measurements rest on. A separate sample holder must match
  the tube bore to ±0.2 % and be sealed with vaseline rather than an elastic
  gasket.
- **The analyser (Clause 4.8).** More than 65 dB of dynamic range, and
  transfer-function errors from non-linearity, resolution, instability and
  temperature under 0.2 dB.

Everything the ISO 10534-2 report needs about the geometry is already in the
fiche's metadata block (tube diameter and shape, microphone spacing, mounting,
temperature and pressure), so that block reads as a report checklist rather
than decoration.

**Tube attenuation, and when to switch it on.** The plane wave in the tube is
not lossless: viscous and thermal boundary layers at the wall attenuate the
incident and the reflected wave over the distance $x_1$, and attenuation that
is not accounted for is read as sample absorption. `tube_attenuation_constant`
is the Eq. (A.18) estimate, $k_0'' = 1.94\times10^{-2}\sqrt{f}/(c_0 d)$, and
its scaling says where it matters: it grows as $\sqrt{f}$ and falls as $1/d$,
so a 29 mm tube suffers roughly three and a half times the loss of a 100 mm one
at the same frequency, and moving the microphone pair closer to the specimen
reduces it directly. It matters most for a near-perfect absorber, where the
reflected wave is already weak. Two cautions come with it. Clause A.2.1.5 says
plainly that this estimate ignores porous or dirty walls and any object in the
tube, so it is a **lower limit**: a large discrepancy is a sign to clean or
re-qualify the tube, not a number to trust. And the standard prefers the
measured route: determine the attenuation from the empty tube at mid and upper
frequencies (Eqs. (A.13)/(A.14), after every modification of the tube) and
extrapolate downwards.

![ISO 10534-2 two-microphone tube result for a 50 mm porous absorber: the normal-incidence absorption coefficient rising from about 0.2 at 200 Hz towards 0.97 above 1 kHz, with the reflection-factor magnitude falling as its mirror image](https://docs.jmrp.io/phonometry/media/impedance_tube_result.svg)

*A 50 mm porous absorber measured over the working band of a 100 mm tube:
the absorption climbs as the layer thickness grows against the wavelength,
and $|r|$ falls as its mirror image ($\alpha = 1 - |r|^2$).*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import materials

# A 50 mm porous absorber (Miki, sigma = 20 kPa s/m^2) in a 100 mm tube with
# 100 mm spacing (working band ~170 Hz to 1.5 kHz): the layer model supplies
# the true reflection factor, from which the transfer function H12 follows.
f = np.linspace(200.0, 1500.0, 260)
med = materials.miki(f, 20000.0)
layer = materials.layered_absorber(f, [materials.PorousLayer(thickness_m=0.05, medium=med)])
spacing, x1, c0 = 0.10, 0.20, 343.2
k0 = materials.tube_wavenumber(f, c0)
x2 = x1 - spacing
r_true = layer.reflection
h12 = (np.exp(1j*k0*x2) + r_true*np.exp(-1j*k0*x2)) / \
      (np.exp(1j*k0*x1) + r_true*np.exp(-1j*k0*x1))
result = materials.two_microphone_impedance(
    h12, frequency=f, spacing_m=spacing, x1=x1, speed_of_sound=c0,
    characteristic_impedance=407.0, diameter_m=0.10,
)

# One line: alpha(f) with |r| overlaid.
result.plot()
plt.show()

# By hand, from the result's fields:
fig, ax = plt.subplots()
ax.plot(f, result.absorption, label="Absorption alpha")
ax.plot(f, np.abs(result.reflection), "--", label="Reflection factor |r|")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Coefficient")
ax.legend()
plt.show()
```

### ISO 10534-2 report (`.report()`)

`ImpedanceTubeResult.report(path)` renders a one-page PDF fiche laid out like an
accredited normal-incidence impedance-tube test report (ISO 10534-2:2001): a
standard-basis line, a metadata header block, the per-frequency table (the
absorption coefficient $\alpha$ and the real and imaginary parts of the
normalised surface impedance $z = Z/\rho c_0$) beside the $\alpha(f)$ curve (the
result's own `.plot()`, on a continuous logarithmic frequency axis), a boxed
characterisation headline and a footer with the fixed disclaimer. ISO 10534-2 is
a characterisation, so the fiche carries no pass/fail verdict and no
single-number rating; the normal-incidence coefficient is not comparable to the
random-incidence $\alpha_\mathrm{s}$/$\alpha_\mathrm{w}$ of ISO 354 / ISO 11654. Setting
`verbose=True` inserts the reflection-factor magnitude $|r|$ column.

It uses the same `ReportMetadata` container and rendering engine as the other
fiches. The measured frequency range is taken from the result; the applicable
descriptive and geometric `ReportMetadata` fields are `client`, `manufacturer`,
`specimen`, `tube_diameter_m`, `tube_shape`, `microphone_spacing_m`, `mounting`,
`test_room`, `test_date`, `temperature_c`, `static_pressure_kpa`,
`measurement_standard`, `laboratory`, `operator`, `report_id` and `notes`
(`tube_diameter_m` and `microphone_spacing_m` are given in metres and printed in
millimetres). The `requirement` field is ignored (ISO 10534-2 has no verdict).
Rendering needs reportlab and, for the figure the fiche embeds, matplotlib
(`pip install "phonometry[report,plot]"`); only `engine="reportlab"` is
supported. The fiche renders in English by default; pass `language="es"` for a
Spanish fiche (translated fixed strings and a comma decimal separator).

The block below is the specimen of the fiche underneath it: a resistive facing
of normalised flow resistance $\theta = 1$ over an 86 mm rigidly-backed air
cavity, whose surface impedance $z = \theta - \mathrm{j}\cot(k_0 L)$ is known
in closed form, so the printed $\alpha$ can be checked by hand: 1.00 at the
1 kHz quarter-wave resonance, where the matched screen gives $z = 1$ and
$r = 0$; 0.80 at 500 Hz, where $k_0 L = \pi/4$ and $z = 1 - \mathrm{j}$.

```python
import numpy as np
from phonometry import ReportMetadata, fluids, materials

# 100 mm tube, s = 50 mm, far microphone at x1 = 100 mm, 20 degC / 101 kPa.
c0 = float(materials.speed_of_sound_iso10534(temperature_c=20.0))   # 343.29 m/s
rho_c = fluids.characteristic_impedance(
    float(materials.air_density_iso10534(
        temperature_c=20.0, static_pressure_kpa=101.0)), c0)   # 405.6 Pa.s/m
diameter_m, spacing, x1 = 0.100, 0.050, 0.100
theta, cavity = 1.0, c0 / (4.0 * 1000.0)          # quarter-wave at 1 kHz: 86 mm
freqs = np.array([400, 500, 630, 800, 1000, 1250, 1600], dtype=float)

# The transfer function the tube would measure, synthesised from the known r.
k0 = materials.tube_wavenumber(freqs, c0)
z = theta - 1j / np.tan(2 * np.pi * freqs / c0 * cavity)
r_known = (z - 1.0) / (z + 1.0)
x2 = x1 - spacing
h12_fiche = (np.exp(1j*k0*x2) + r_known*np.exp(-1j*k0*x2)) / \
            (np.exp(1j*k0*x1) + r_known*np.exp(-1j*k0*x1))

fiche = materials.two_microphone_impedance(
    h12_fiche, frequency=freqs, spacing_m=spacing, x1=x1,
    speed_of_sound=c0, characteristic_impedance=rho_c, diameter_m=diameter_m,
)
print(np.round(fiche.absorption, 2))    # [0.68 0.8  0.9  0.97 1.   0.96 0.68]

fiche.report(
    "alpha_fiche.pdf",
    metadata=ReportMetadata(
        specimen="Resistive facing over an 86 mm rigidly-backed air cavity",
        tube_diameter_m=diameter_m,        # m (printed as 100 mm)
        microphone_spacing_m=spacing,           # m (printed as 50 mm)
        measurement_standard="ISO 10534-2",
        laboratory="Phonometry Reference Laboratory",
    ),
)                       # normal-incidence alpha and impedance over the tube band
```

**Report:** [ISO 10534-2 impedance-tube example report (PDF)](https://docs.jmrp.io/phonometry/media/iso10534_impedance_tube_example.pdf): One-page normal-incidence impedance-tube fiche: a metadata header (client, specimen, tube diameter d, microphone spacing s, the measured frequency range, mounting, test facility, temperature and pressure), the per-frequency table of the absorption coefficient alpha and the real and imaginary parts of the normalised surface impedance z beside the alpha curve on a logarithmic frequency axis, and the boxed characterisation headline over the tested frequency range.

Normal-incidence impedance-tube fiche (ImpedanceTubeResult.report), the alpha spectrum with the surface impedance.

## 4. Transmission loss (ASTM E2611)

With four microphones (two upstream, two
downstream of the sample) a two-load (or one-load) measurement recovers the
sample's transfer matrix, whose entries give the normal-incidence transmission
loss, reflection and wavenumber:

$$
\mathrm{TL} = 20\log_{10}\left|\frac{T_{11} + T_{12}/\rho c
             + \rho c\,T_{21} + T_{22}}{2}\right|.
$$

**What a "load" is, and why there are two of them.** A load is a downstream
termination. The matrix has four unknowns, and one measurement of the four
microphone transfer functions supplies only two independent equations, so the
general method changes the termination and repeats the whole measurement:
E2611 Clause 8.5.4.1 solves the two sets together (Eq. (22)). In practice the
tube ends in a weakly anechoic termination (a wedge or pyramid of glass fibre
about 30 cm long) and Clause 6.2.8 asks for it to be *easily removable*
precisely so that an open or a blocked end can provide the second load. All
four transfer functions of each load are referenced to one common channel, and
each of them carries the same switched-configuration mismatch correction as
section 3 (Clause 8.5.3): the four-microphone method does not escape that
requirement, it multiplies it. The source end is sealed and isolated from the
tube (Clause 6.4.2), as in Part 2.

**The one-load method is not the general method with fewer steps.** Clause
8.5.4.2 closes the system instead by *assuming* the specimen is geometrically
symmetric ("presenting the same physical properties to the sound field on
either side") so that reciprocity gives $T_{11} = T_{22}$ and
$T_{11}T_{22} - T_{12}T_{21} = 1$ (Eq. (23)), and one termination, preferably
the anechoic one, is enough. That holds for a homogeneous layer and fails for
any asymmetric build-up: a facing on one side, a gradient density, a mounted
membrane, a stack of unequal layers (which is most of what people actually put)
in a transmission tube. `transfer_matrix_one_load` does not and cannot detect
the asymmetry: it warns about the plane-wave range and about an ill-conditioned
denominator, and otherwise returns a plausible, wrong matrix, and with it a
wrong transmission loss. The rule is simple: if the specimen has a front and a
back, use two loads. If you believe it is symmetric, run both solvers and
compare. None of this touches the hard-backed absorption route of section 3,
which needs only the surface impedance.

![ASTM E2611 four-microphone transmission-loss tube: a sound source, two microphones upstream and two downstream of the test specimen at spacings s1 and s2 and offsets l1 and l2, an adjustable termination for the two-load method, the upstream A and B and downstream C and D travelling waves, and the transfer matrix and transmission-loss relations](https://docs.jmrp.io/phonometry/media/diagram_astm_tube.svg)

To scale it looks like this. A `TransferMatrix` recovered by the two-load or
one-load solvers retains `l1`, `s1`, `l2`, `s2` and the specimen thickness,
so `tm.plot_geometry()` redraws the tube a measurement was taken in.

![To-scale side view of a 100 mm ASTM E2611 transmission tube: the loudspeaker at the left, microphones 1 and 2 upstream at s1 = 50 mm spacing and l1 = 100 mm from the specimen, the 50 mm specimen in the middle of the tube, microphones 3 and 4 downstream at s2 = 50 mm spacing and l2 = 200 mm, the changeable termination of the two-load method at the right, the circular cross-section beside the tube and the plane-wave working range of 69 to 2011 Hz](https://docs.jmrp.io/phonometry/media/transmission_tube_geometry.svg)

*Where the four microphones of the transfer-matrix method actually sit
around a 50 mm specimen in a 100 mm tube: $s_1 = s_2$ = 50 mm,
$l_1$ = 100 mm, $l_2$ = 200 mm, and the changeable termination that
provides the second load. The ASTM working range for this geometry is
69 to 2011 Hz.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import materials

materials.plot_transmission_tube_geometry(
    l1=0.10, s1=0.05, l2=0.20, s2=0.05, thickness_m=0.05, diameter_m=0.10,
)
plt.show()

# A TransferMatrix from transfer_matrix_two_load / _one_load retains its
# geometry, so tm.plot_geometry() redraws the tube it was measured in.
```

```python
import numpy as np
from phonometry import materials

# An air layer is a known transfer matrix; TL = 0 dB (nothing is lost)
f = np.array([500.0, 1000.0, 2000.0])
k0 = 2*np.pi*f / 343.2
rho_c = 1.186 * 343.2
tm = materials.air_layer_transfer_matrix(thickness_m=0.05, wavenumber=k0,
                               characteristic_impedance=rho_c)
print(np.round(tm.transmission_loss(rho_c), 6))   # [0. 0. 0.]
```

`transfer_matrix_two_load` / `transfer_matrix_one_load` build the
`TransferMatrix` from the four measured microphone transfer functions
`(H1, H2, H3, H4)` of each load; its methods
(`transmission_loss`, `reflection_hard_backed`, `absorption_hard_backed`,
`characteristic_impedance_material`, `material_wavenumber`) then read off the
ASTM E2611 quantities, and its `.plot()` draws the transmission loss with
the hard-backed absorption overlaid (a matrix built by the solvers retains
$\rho c$ and, when supplied, the frequency vector, so only a hand-built
matrix needs them as arguments). The matrix does
not have to come from a measurement: the
[multilayer solver](https://docs.jmrp.io/phonometry/materials/absorbers/porous-absorbers/) exposes the chain
matrix of any modelled stack in the same convention, so a predicted specimen
can be read out exactly like a measured one.

```python
import numpy as np
from phonometry import materials

# The chain matrix of a modelled 50 mm porous layer, read back through the
# ASTM E2611 machinery: TL and hard-backed absorption of the same specimen.
f = np.linspace(200.0, 1600.0, 300)
med = materials.miki(f, 20000.0)
layer = materials.layered_absorber(f, [materials.PorousLayer(thickness_m=0.05, medium=med)])
chain = layer.transfer_matrix                       # shape (2, 2, len(f))
tm = materials.TransferMatrix(t11=chain[0, 0], t12=chain[0, 1],
                              t21=chain[1, 0], t22=chain[1, 1])
print(np.round(float(tm.transmission_loss(407.0)[-1]), 1))   # 9.7 dB at 1.6 kHz
# TL(f) with the hard-backed absorption overlaid
tm.plot(frequencies=f, characteristic_impedance=407.0)
```

![ASTM E2611 transfer-matrix quantities of a 50 mm porous layer: the normal-incidence transmission loss rising from about 6.6 dB at 200 Hz to over 9 dB at 1.6 kHz on the left axis, and the hard-backed absorption coefficient rising from 0.19 to about 0.97 on the right axis](https://docs.jmrp.io/phonometry/media/transfer_matrix_tl.svg)

*The same four-pole entries answer two different questions: how much sound
the free-standing layer lets through (the transmission loss, Eq. (26)) and
how much the rigidly-backed layer absorbs (Eq. (28)).*

**A tube TL is not a sound reduction index.** The fiche of section 3 warns
that the normal-incidence $\alpha$ is not the random-incidence $\alpha_\mathrm{s}$; the
same warning applies on the transmission side and is missed more often. What
the tube measures is the transmission loss of a specimen a few centimetres
across, for one plane wave at one angle, with the specimen edges clamped by
the tube wall. What the
[sound reduction index $R$](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/) is,
is a diffuse-field quantity measured on a full-size element with its real
mounting, and it carries the element's own bending waves, its edge conditions
and its coincidence dip, none of which exist inside a tube. Expect the
normal-incidence value to sit *above* a field-incidence estimate for a
mass-controlled layer, and expect the tube to miss the resonance and
coincidence dips of a real panel entirely. Use the tube TL to compare
materials and to fit and verify a transfer-matrix model; then predict the
construction with the model, or with
[EN 12354](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/), and never by
carrying the tube number into a partition calculation.

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import materials

f = np.linspace(200.0, 1600.0, 300)
med = materials.miki(f, 20000.0)
layer = materials.layered_absorber(f, [materials.PorousLayer(thickness_m=0.05, medium=med)])
chain = layer.transfer_matrix                       # shape (2, 2, len(f))
tm = materials.TransferMatrix(t11=chain[0, 0], t12=chain[0, 1],
                              t21=chain[1, 0], t22=chain[1, 1])

# One line: TL(f) on the left axis, hard-backed absorption on the right.
tm.plot(frequencies=f, characteristic_impedance=407.0)
plt.show()

# By hand, from the matrix methods:
fig, ax = plt.subplots()
ax.plot(f, tm.transmission_loss(407.0), label=r"Transmission loss $\mathrm{TL}_\mathrm{n}$")
twin = ax.twinx()
twin.plot(f, tm.absorption_hard_backed(407.0), "--", color="gray",
          label="Hard-backed absorption alpha")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel(r"Transmission loss $\mathrm{TL}_\mathrm{n}$ [dB]")
twin.set_ylabel("Hard-backed absorption alpha")
plt.show()
```

## Mounting pitfalls

Most bad tube data are made at the sample holder, long
before the signal processing. The recurring failures:

- **Perimeter gaps.** A specimen cut slightly undersize leaves an air sliver
  along the tube wall. Sound short-circuits around and behind the sample, and
  the gap itself resonates, so the measured absorption grows a spurious
  low-to-mid-frequency hump. Cut for a snug slide fit and seal the rim (a thin
  film of petroleum jelly is the classic remedy) without loading the front
  face.
- **Compression.** A specimen cut oversize and forced in is denser than the
  product it is supposed to represent: the flow resistivity rises, a limp
  frame is stiffened, and the absorption curve shifts and flattens. The result
  is repeatable and wrong.
- **Hidden back cavity.** If the specimen does not sit flush on the rigid
  backing, the unintended air layer acts as a quarter-wavelength cavity and
  moves the absorption peak down in frequency, flattering the material.
  Backing air gaps are perfectly legitimate mountings, but only when they are
  deliberate, dimensioned and reported with the result.
- **Face not plane.** A bulging, tilted or torn front face scatters into
  cross-sectional modes below the nominal cut-on and breaks the
  normal-incidence assumption the equations rest on. Cut with a sharp tool;
  do not tear fibrous materials to size.
- **One specimen is not the material.** Porous products are inhomogeneous at
  the scale of a tube sample. Measure several cuts and average; a spread
  between specimens is product variance worth reporting, not measurement noise
  to hide.

## 5. The virtual tube: the solver measured by the standards

A three-row rigid-walled domain of the
[2D FDTD solver](https://docs.jmrp.io/phonometry/simulation/fdtd-simulation/) is a plane-wave tube,
and with the per-cell `damping` map a porous sample becomes an equivalent
fluid (density, speed and loss maps). That closes a remarkable loop: the FDTD probe histories can
be reduced through the library's own ISO 10534-2 and ASTM E2611 chains as
if they were measurements, and the recovered spectra agree with the exact
analytic answer for the same lossy layer to within 0.035 in absorption and
0.1 dB in transmission loss (the `tests/simulation` cross-checks run this
on every commit).

```python
import numpy as np
from phonometry.materials import two_microphone_impedance
from phonometry.simulation import FDTD2D

c0, rho0, dx = 343.0, 1.2, 0.005
nx, d_cells = 280, 20                     # 1.4 m tube, 10 cm sample
c = np.full((3, nx), c0); rho = np.full((3, nx), rho0)
sigma = np.zeros((3, nx))
c[:, -d_cells:] = 0.6 * c0                # the sample: slower,
rho[:, -d_cells:] = 3.0 * rho0            # denser and lossy
sigma[:, -d_cells:] = 600.0
sim = FDTD2D(c=c, dx=dx, rho=rho, damping=sigma,
             edge_impedance={"left": rho0 * c0})   # anechoic source end
sim.add_plane_wave("right", center_m=0.35, half_width_m=0.05)
mics = (219, 229)                         # the ISO microphone pair
records = np.zeros((2, 9000))
for n in range(records.shape[1]):
    sim.step()
    records[:, n] = sim.p[1, mics]
spec = np.fft.rfft(records, axis=1)
freqs = np.fft.rfftfreq(records.shape[1], sim.dt)
band = (freqs > 300.0) & (freqs < 1200.0)
result = two_microphone_impedance(
    spec[1, band] / spec[0, band], frequency=freqs[band],
    spacing_m=0.05, x1=(nx - d_cells) * dx - (mics[0] + 0.5) * dx,
    speed_of_sound=c0, characteristic_impedance=rho0 * c0)
result.plot()   # the absorption the virtual tube "measured"
```

The two clips below run exactly this experiment. In the impedance tube a
sustained plane tone builds the standing wave the two microphones read:
against the rigid end the minima are deep, in front of the sample they stay
shallow. In the transmission tube a carrier packet crosses an anechoic
duct: the empty tube passes it unchanged, the lossy layer splits it into a
reflection and an attenuated transmission that the four ASTM microphones
resolve.

**Video:** [The virtual impedance tube in a 2D FDTD simulation](https://docs.jmrp.io/phonometry/media/anim_fdtd_impedance_tube.webm): A loudspeaker drives a sustained 850 Hz plane tone into a 1.2 metre rigid-walled virtual impedance tube, drawn as the real instrument with its two flush microphones and rigid end plug. Against the rigid plug the standing-wave envelope grows deep minima, while a 10 cm lossy sample in front of the same plug leaves the minima shallow; the recovered absorption of 0.54 is annotated.

**Video:** [The virtual transmission tube in a 2D FDTD simulation](https://docs.jmrp.io/phonometry/media/anim_fdtd_transmission_tube.webm): The loudspeaker end fires a carrier packet down a 1.6 metre rigid-walled virtual transmission tube drawn as the real instrument, with its four flush microphones and hatched anechoic termination. The empty tube passes the packet unchanged; a 10 cm lossy layer mid-tube splits it into a reflected train and an attenuated transmission, with the 3.1 dB transmission loss annotated.

## What this guide covers

- **Covered.** The impedance-tube trio. The ISO 10534-1 standing-wave-ratio method
  (`standing_wave_ratio_from_level`, `standing_wave_reflection_magnitude`,
  `standing_wave_absorption`, and the position half of the reading in
  `standing_wave_reflection` and `standing_wave_normalized_impedance`). The ISO
  10534-2 transfer-function method with its Clause 4 frequency-range check
  (`two_microphone_impedance`, `plane_wave_frequency_range`,
  `reflection_factor`, `absorption_from_reflection`,
  `normalized_surface_impedance`, `normalized_surface_admittance`, the Clause
  7.2 air properties `speed_of_sound_iso10534` and `air_density_iso10534`, the Clause 7.5
  mismatch pair `microphone_calibration_factor` and `apply_microphone_calibration`, and
  `tube_attenuation_constant`). The ASTM E2611 four-microphone transfer-matrix
  method (`transfer_matrix_two_load`, `transfer_matrix_one_load`,
  `TransferMatrix`, `plane_wave_frequency_range_astm_e2611`, `hydraulic_diameter`),
  with the to-scale geometry drawings of both tubes. The virtual FDTD tubes of
  section 5, whose recovered spectra are cross-checked against the analytic
  answer on every commit.

- **Not covered.** Two editions cited only as later revisions are not implemented: ISO
  10534-2:2023 (the code follows the 1998/2001 transfer-function method) and
  ASTM E2611-24 (the code follows E2611-19). ISO 10534-1:1996 is implemented as
  its European adoption BS EN ISO 10534-1:2001, not read directly from the 1996
  ISO text; its probe-traverse refinements (extrapolating the minimum levels to
  the sample face, probe-body corrections) are described in section 2 but not
  automated. Neither are the equipment and procedure clauses of sections 1.1 and
  3.2: the near-field distances of Clause 4.3, the position tolerances of Clause
  4.5, the signal-to-noise floor of Clause 7.3 and the warm-up of Clause 5 are
  stated for the operator, and nothing in the library checks that any of them
  was met. `tube_attenuation_constant` implements only the Eq. (A.18) estimate,
  which the standard itself calls a lower limit; the measured determination of
  Eqs. (A.13)/(A.14) from the empty tube is not implemented. The
  random-incidence $\alpha_\mathrm{s}$ of the reverberation room is a different quantity
  with its own guide: [Sound Absorption Measurement and
  Rating](https://docs.jmrp.io/phonometry/materials/absorbers/absorption-measurement/).

## See also

- [Sound Absorption Measurement and Rating](https://docs.jmrp.io/phonometry/materials/absorbers/absorption-measurement/):
  the random-incidence reverberation-room coefficient, its ISO 11654 rating,
  and when the tube or the room is the right instrument.
- [Airflow Resistance](https://docs.jmrp.io/phonometry/materials/absorbers/airflow-resistance/): the ISO 9053
  flow resistivity that anchors the models a tube measurement is fitted
  against.
- [Porous and Multilayer Absorbers](https://docs.jmrp.io/phonometry/materials/absorbers/porous-absorbers/): the
  equivalent-fluid models and the multilayer solver whose chain matrix reads
  out through the same ASTM E2611 machinery as a measured specimen.
- [FDTD Simulation](https://docs.jmrp.io/phonometry/simulation/fdtd-simulation/): the 2D solver behind
  the virtual tubes of section 5.
- [Calibration](https://docs.jmrp.io/phonometry/signals/metrology/calibration/): microphone calibration ahead
  of the two-microphone transfer function.
- API reference: [`materials.absorbers.impedance_tube`](https://docs.jmrp.io/phonometry/reference/api/materials/impedance-tube/).
- Theory: [Acoustic material characterisation](https://docs.jmrp.io/phonometry/reference/theory/materials-surfaces/#acoustic-material-characterisation-iso-11654-iso-9053-12-iso-10534-12-astm-e2611): the transfer-function derivation of ISO 10534-2 and the ASTM E2611 four-microphone extension.

## References

- **Allard, J. F., & Atalla, N. (2009).** *Propagation of sound in porous media: Modelling sound absorbing materials* (2nd ed.). Wiley. https://doi.org/10.1002/9780470747339
  The porous-material theory behind the measured quantities: the surface impedance and absorption the tube recovers, and the models fitted to them. ISBN 978-0-470-74661-5.
- **ASTM International. (2019).** [*Standard test method for normal incidence determination of porous material acoustical properties based on the transfer matrix method*](https://store.astm.org/e2611-19.html) (ASTM E2611-19).
  The four-microphone transfer-matrix method of section 4 behind the transmission-loss helpers. The edition implemented here; since revised as ASTM E2611-24 (https://store.astm.org/e2611-24.html).
- **International Organization for Standardization. (1996).** [*Acoustics — Determination of sound absorption coefficient and impedance in impedance tubes — Part 1: Method using standing wave ratio*](https://www.iso.org/standard/18603.html) (ISO 10534-1:1996).
  The standing-wave-ratio method of section 2; the edition implemented here is its European adoption BS EN ISO 10534-1:2001.
- **International Organization for Standardization. (1998).** [*Acoustics — Determination of sound absorption coefficient and impedance in impedance tubes — Part 2: Transfer-function method*](https://www.iso.org/standard/22851.html) (ISO 10534-2:1998).
  The two-microphone transfer-function method of section 3 and its plane-wave frequency-range limits. Adopted in Europe as EN ISO 10534-2:2001, the edition implemented here; since revised as ISO 10534-2:2023 (https://www.iso.org/standard/81294.html).
