# Wind-turbine noise: sound power and tonal audibility

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/environment/sources/wind-turbine-noise/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/environment/sources/wind-turbine-noise/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-12
Updated: 2026-11-16T21:36:14Z
Standards: IEC 61400-11:2012+AMD1:2018 CSV
Verified: 4 conformance checks (IEC 61400-11:2012+AMD1:2018 CSV) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: IEC 61400-11 wind-turbine emission: apparent sound power level at the rotor centre, and the tonal-audibility chain that decides if a tone is audible.

---

IEC 61400-11 measures the acoustic emission of a wind turbine. This page covers
its two closed-form quantities: the **apparent sound power level** referred to
an equivalent point source at the rotor centre, and the **tonal audibility**
that decides whether a discrete tone (blade-passing, gearbox, generator) is
audible above the masking noise. Both are checked against the standard's
formulas, and the audibility also against a synthetic tone whose audibility is
worked out by hand.

## Apparent sound power level

With the reference microphone on a ground board at the horizontal distance
$R_0 = H + D/2$ (hub height $H$, rotor diameter $D$), the slant distance to
the rotor centre is $R_1 = \sqrt{H^2 + R_0^2}$ and the apparent sound power
level is $L_{W\mathrm{A},i} = L_{p,i} - 6 + 10\log_{10}(4\pi R_1^2/S_0)$ per band
($S_0 = 1\ \text{m}^2$), energy-summed over bands (Formula 27). The −6 dB accounts for the
ground-board pressure doubling.

![Side view of a horizontal-axis wind turbine with hub height H and rotor diameter D, a microphone lying on a flat ground board downwind at the horizontal distance R0 = H + D/2 from the tower centreline, the slant distance R1 from the rotor centre to the microphone with the board inclination angle phi between 25 and 40 degrees, and a met mast measuring wind speed and direction; a plan-view inset shows the Figure 3 pattern with the reference position downwind and three optional positions at plus and minus 60 degrees and upwind, and the annotations give R1 equals the square root of H squared plus R0 squared and the apparent sound power formula LWA,i = Lp,i minus 6 plus 10 lg(4 pi R1 squared over S0)](https://docs.jmrp.io/phonometry/media/diagram_wind_turbine_iec61400.svg)

```python
from phonometry import environment

# Background-corrected A-weighted one-third-octave band levels L_p,i (dB),
# here the 250 Hz to 1 kHz bands of a downwind ground-board measurement.
band_levels = [55.0, 58.0, 60.0, 57.0, 54.0]          # 250, 400, 500, 800, 1000 Hz
r1 = environment.slant_distance(hub_height_m=80.0, rotor_diameter_m=100.0)
print(round(r1, 2))                                   # 152.64 m
lwa = environment.apparent_sound_power_level(band_levels, r1)   # dB re 1 pW
print(round(float(lwa), 2))                           # 112.98 dB(A) re 1 pW
```

### The measurement position in practice

The −6 dB above is only the board's pressure doubling if the board really is a
board. IEC 61400-11:2012+A1:2018 fixes what that means, and a tripod microphone
or a small plate gives an incoherent reflection instead, which puts the apparent
sound power out by an unknown amount rather than a correctable one.

![Two panels of the IEC 61400-11 ground-board microphone mounting. Plan: the circular board with its minimum diameter of 1.0 m dimensioned, the microphone at the centre with its axis pointing at the turbine, and the optional split line drawn off the centre line and parallel to that axis with its maximum 1 mm gap called out. Section: the board edge with a soil fillet levelling the gap underneath, the board thickness annotated as at least 12.0 mm for plywood or hard chip-board and at least 2.5 mm for metal, the capsule with its diaphragm in the plane of the board and a diameter of at most 13 mm, the primary windscreen drawn as a half sphere of open-cell foam about 90 mm across centred on the diaphragm, and a ghosted secondary windscreen tagged as usable only in high wind and only if its insertion loss is documented and corrected band by band](https://docs.jmrp.io/phonometry/media/diagram_wind_turbine_board.svg)

| Requirement | Value | Clause |
| :--- | :--- | :--- |
| Measurement chain | IEC 61672 class 1; filters IEC 61260 class 1; 1/3 octaves from 20 Hz to 10 kHz determined simultaneously; narrowband over 20 Hz to 11 200 Hz | 6.1.2, 6.1.3, 6.1.4 |
| Microphone diaphragm | ≤ 13 mm, in a plane **normal to the board**, axis pointing at the turbine | 6.1.2, 6.1.5 |
| Board | Circular, diameter ≥ 1.0 m, acoustically hard: plywood or hard chip-board ≥ 12.0 mm, or metal ≥ 2.5 mm | 6.1.5 |
| A split board | Pieces level in one plane, gap < 1 mm, split off the centre line and **parallel** to the microphone axis | 6.1.5 |
| Seating | Flat on the ground, edges and gaps underneath levelled out with soil | 7.1 |
| Windscreen | Primary: half an open-cell foam sphere ≈ 90 mm across, centred on the diaphragm. Secondary only where a high wind makes the low-frequency signal-to-noise ratio inadequate, and then its frequency response must be documented and **corrected in 1/3-octave bands** | 6.1.5, Annex E |
| Direction | Within ±15° of the downwind direction at the time of measurement | 7.1 |
| Distance | $R_0$ to ±20 %, at most ±30 m, measured to ±2 %, and as close to $R_0$ as possible; using the tolerance has to be justified in the report | 7.1 |
| Inclination | $\varphi$ between 25° and 40°, adjusting the position inside the tolerances above if necessary | 7.1 |
| Reflections | The calculated influence of any reflecting structure < 0.2 dB | 7.1 |
| Calibration | Class 1 IEC 60942 calibrator on the microphone immediately **before and after** every session, and again whenever a microphone is disconnected and reconnected | 6.1.6, 7.2.2 |
| Traceable verification | Acoustic calibrator 12 months; microphone, sound level meter, recorder, anemometer, power and temperature transducers 24 months; spectrum analyser 36 months | 6.3 |

The causal chain is worth holding on to. The board is what makes the reflection
coherent, so the board decides whether the −6 dB is a constant or a guess; the
foam hemisphere is what keeps the wind that drives the emission from also
driving the microphone's own self-noise; and the secondary windscreen is the one
piece of the setup that changes the answer without changing the sound, which is
why the standard makes its insertion loss a documented, band-by-band correction
rather than an accepted loss. One measurement position is required and three
more are optional: the reference position is downwind and the others exist to
document how the emission varies around the machine, not to be averaged with it.

### Why "apparent"

$L_{W\mathrm{A}}$ is written like a sound power level, but it is not one in the
ISO 3744 sense of sampling the pressure field over an enveloping
surface. The
standard collapses the whole machine into an equivalent point source at the
rotor centre and asks what power that source would need, radiating
spherically, to reproduce the measured level at one downwind ground-board
position: by definition it is the power "giving the same sound emission in
the downwind direction as the wind turbine". Everything a 150 m rotor does
that a point source does not, the vertical and lateral directivity and the
blade-passing swish, is folded into the number and evaluated in a
single direction; the optional positions 2 to 4 of the plan-view pattern
exist precisely to document how the emission varies around the machine.
Apparent sound powers of different turbines are comparable because the
geometry scales with the machine ($R_0 = H + D/2$, so every rotor is seen
under a similar angle), which is the point of the definition, but an
$L_{W\mathrm{A}}$ fed into an ISO 9613-2 prediction carries its built-in downwind
bias with it. The ground board, in turn, is why the formula subtracts 6 dB:
a capsule lying on a hard plate receives a perfectly coherent reflection
(pressure doubling, $+6$ dB) instead of the uncontrolled height-dependent
interference pattern a tripod microphone would sample (see
[the image source behind the ground effect](https://docs.jmrp.io/phonometry/environment/propagation/outdoor-propagation/)).

### Wind-speed bins and standardized conditions

A turbine's noise emission rises with wind speed toward rated power, so a
single number would be meaningless without its operating point: IEC 61400-11
reports $L_{W\mathrm{A}}$ *as a function of wind speed*.

**How a bin is filled.** Sound and wind are logged in synchronized 10 s
averages, and every period is sorted into a wind-speed **bin 0.5 m/s wide
centred on integer and half-integer hub-height wind speeds**, with at least 10
periods of total noise and 10 of background (turbine parked) per bin. Within
each bin the spectra are averaged, interpolated to the bin centre and
background-corrected; a total-minus-background margin of 3 dB or less voids the
bin, between 3 and 6 dB flags it with an asterisk.

**Where the wind speed comes from.** Preferably not from an anemometer at all:
it is derived from the measured electric power through the turbine's power curve
(Clause 8.2.1), the most repeatable proxy for the wind the rotor actually sees,
with the nacelle anemometer and a met mast as fallbacks. The measured range must
at least cover 0.8 to 1.3 times the wind speed at 85 % of maximum power (roughly
6 to 10 m/s at 10 m height for a large machine).

**Why the abscissa is reported twice.** For comparability with consent
conditions and older editions, Formula (29) also maps each result to the wind
speed at 10 m height over a **reference roughness length** $z_{0\mathrm{ref}} = 0.05$ m
(a logarithmic wind profile), giving $L_{W\mathrm{A},10\mathrm{m}}$ at integer 10 m wind speeds
regardless of the site's actual terrain. The library implements the closed-form quantities of this pipeline
(slant distance, per-band apparent power, tonal audibility); the binning,
averaging and uncertainty machinery operates on whole measurement campaigns
and stays out of scope.

![The A-weighted apparent sound power level of an 80 m hub, 100 m rotor turbine against hub-height wind speed, one marker per 0.5 m per second bin from 4 to 12 m per second. The curve rises from about 98.6 dB at 4 m per second through its steepest part near 7 m per second and flattens at about 110 dB above 10 m per second as the machine reaches rated power. One low bin is shaded and struck through because its total minus background margin is under 3 dB, and a neighbouring bin carries an asterisk because its margin is between 3 and 6 dB. A twin abscissa above the plot repeats the same series against the Formula 29 wind speed at 10 m height over the reference roughness length of 0.05 m](https://docs.jmrp.io/phonometry/media/wind_turbine_apparent_power.svg)

*The quantity this standard reports is a curve, not a number: the same machine
is 98.6 dB(A) at 4 m/s and 109.9 dB(A) at 12 m/s. The shape is the machine's
control strategy: steepest where the rotor is accelerating, flat once it is at
rated power, so quoting a single $L_{W\mathrm{A}}$ without its wind speed says nothing.
The struck bin and the asterisked one are the standard's own bookkeeping: below
a 3 dB total-minus-background margin the bin is void, between 3 and 6 dB it is
reported with a flag. The upper axis is the same series against the Formula (29)
10 m reference wind speed, which is what a consent condition is usually written
in and is not the speed the rotor saw.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `environment` is imported by the snippet above. The per-bin band levels here
# are synthetic: a real campaign supplies them, background-corrected and
# interpolated to the bin centre.
r1 = environment.slant_distance(hub_height_m=80.0, rotor_diameter_m=100.0)
bins = np.arange(4.0, 12.5, 0.5)
shape = np.array([-4.0, -1.5, 0.0, -1.0, -3.0])   # 250 Hz to 1 kHz
lwa = [float(environment.apparent_sound_power_level(
    44.0 + 12.0 / (1.0 + np.exp(-(v - 7.0))) + shape, r1)) for v in bins]

fig, ax = plt.subplots()
ax.plot(bins, lwa, "o-")
ax.set_xlabel("Hub-height wind speed [m/s]")
ax.set_ylabel("Apparent sound power level LWA [dB(A) re 1 pW]")
plt.show()
```

## Tonal audibility

From a narrowband spectrum (1–2 Hz resolution), the lines in the **critical
band** about the tone,
$\mathrm{CBW} = 25 + 75\,[\,1 + 1.4\,(f_\mathrm{c}/1000)^2\,]^{0.69}$ Hz, are
classified into masking noise and tone lines (the 70 %-lowest energy mean, the
+6 dB criteria; tone lines must additionally lie within 10 dB of the
*highest* line above the threshold, and that highest line is the frequency of
the tone, subclauses 9.5.3/9.5.4). The candidate itself must first pass the
9.5.2 *possible tone* screening: a local maximum more than 6 dB above the
band energy average excluding the maximum and its adjacent lines.

For a candidate between **20 and 70 Hz** the Zwicker expression is not
meaningful (it is at the bottom of the audible range) and subclause 9.5.3
replaces it with the fixed **absolute 20-120 Hz band**. The returned
`critical_bandwidth` is then 100 Hz for every such candidate and the band is
*not centred on the tone*, which is why a low-frequency
`WindTurbineTonalityResult` cannot be reconciled with the formula printed above.
For a wind turbine that is not a corner case: blade-passing harmonics and
low-speed gearbox tones live exactly there. The
masking-noise level $L_{p\mathrm{n}}$ follows Formula 31, the
tonality is $\Delta L_\mathrm{tn} = L_{p\mathrm{t}} - L_{p\mathrm{n}}$, and the tonal audibility is
$\Delta L_\mathrm{a} = \Delta L_\mathrm{tn} - L_\mathrm{a}$ with
$L_\mathrm{a} = -2 - \log_{10}\!\big[1 + (f/502)^{2.5}\big]$, reported when
$\Delta L_\mathrm{a} \ge -3\ \text{dB}$ and audible when $\Delta L_\mathrm{a} > 0$.

![Two panels against tone frequency on a logarithmic axis from 20 Hz to 10 kHz. Left: the IEC 61400-11 critical bandwidth, flat near 100 Hz through the low and mid bands and opening steeply above 500 Hz to 2 kHz wide at 10 kHz, with the fixed 20 to 120 Hz low-frequency band of subclause 9.5.3 drawn as a separate flat segment over the 20 to 70 Hz candidate range and the ISO 1996-2 Table C.1 bandwidth drawn as a stepped dashed line for contrast. Right: the audibility criterion La, which falls from minus 2 dB at low frequency to minus 4.5 dB at 5 kHz, redrawn as the tonality a tone must reach to be audible and to be reportable, so a 100 Hz tone needs about half a decibel more emergence than a 1 kHz one](https://docs.jmrp.io/phonometry/media/wind_turbine_audibility_criterion.svg)

*Left: two different critical bandwidths live on this page. The IEC 61400-11
Zwicker band is what `WindTurbineTonalityResult.critical_bandwidth` reports
(117.3 Hz for the 500 Hz tone of the fiche below), while
`environment.critical_bandwidth` is the **ISO 1996-2 Table C.1** band (100 Hz
up to 500 Hz and 20 % of $f_\mathrm{c}$ above it) used by the ISO tonal-audibility
route on the environmental-levels page. They are not interchangeable. Right: the
criterion is nearly flat below 500 Hz and then tightens, so a low-frequency tone
is judged on almost the same emergence as a mid-frequency one; the reportable
line sits 3 dB below the audible one everywhere.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `environment` is the module imported by the snippets above.
fc = np.geomspace(20.0, 10000.0, 400)
zwicker = 25.0 + 75.0 * (1.0 + 1.4 * (fc / 1000.0) ** 2) ** 0.69
la = -2.0 - np.log10(1.0 + (fc / 502.0) ** 2.5)

fig, (left, right) = plt.subplots(1, 2, figsize=(12, 4.4))
left.loglog(fc, zwicker, label="IEC 61400-11 critical band (Zwicker)")
left.loglog(fc, [environment.critical_bandwidth(float(f)) for f in fc], "--",
            label="ISO 1996-2 Table C.1")
left.plot([20.0, 70.0], [100.0, 100.0], lw=4,
          label="9.5.3: fixed 20-120 Hz band")
left.set(xlabel="Tone frequency fc [Hz]", ylabel="Critical bandwidth [Hz]")
left.legend(fontsize="small")

right.semilogx(fc, -la, label="Tonality needed to be audible")
right.semilogx(fc, -la - 3.0, "--", label="Tonality needed to be reportable")
right.set(xlabel="Tone frequency [Hz]",
          ylabel="Required tonality dLtn [dB]")
right.legend(fontsize="small")
plt.show()
```

![A wind-turbine narrowband spectrum with a discrete tone near 200 Hz standing above a shaped broadband floor, the critical band about the tone shaded, the masking-noise level drawn as a horizontal line, and the tonal audibility annotated](https://docs.jmrp.io/phonometry/media/wind_turbine_tonality.svg)

*What the method actually compares. The 200 Hz line stands 22 dB above the
shaped floor, but the verdict is not that number: inside the 102.9 Hz critical
band the classified tone lines sum to $L_{p\mathrm{t}}$ = 62.2 dB and the masking noise
to $L_{p\mathrm{n}}$ = 55.6 dB, so the tonality is 6.6 dB. Only after subtracting the
audibility criterion $L_\mathrm{a} = -2.0$ dB at this frequency does the reportable
quantity appear, $\Delta L_\mathrm{a}$ = 8.6 dB, well over the 0 dB that makes the tone
audible. The shaded band, not the line height, is what sets it.*

**Show the code for this figure**

```python
import numpy as np
from phonometry import environment

df = 2.0
freqs = np.arange(50.0, 400.0 + df, df)
levels = 42.0 - 6.0 * np.log10(freqs / 100.0)
levels[int(np.argmin(np.abs(freqs - 200.0)))] += 22.0   # blade-passing-style tone
environment.wind_turbine_tonality(levels, frequencies=freqs, tone_frequency=200.0).plot()
```

```python
import numpy as np
from phonometry import environment

# A uniformly-spaced narrowband spectrum (2 Hz resolution): a flat 30 dB floor
# with a discrete 60 dB tone at 500 Hz.
frequencies = np.arange(440.0, 562.0, 2.0)
levels = np.full(frequencies.size, 30.0)
levels[np.argmin(np.abs(frequencies - 500.0))] = 60.0

res = environment.wind_turbine_tonality(levels, frequencies=frequencies)
print(res.tone_frequency, res.tonality, res.tonal_audibility, res.is_audible)
res.plot()   # spectrum + critical band + masking level (needs matplotlib)
```

`wind_turbine_tonality` returns a `WindTurbineTonalityResult` with the
`critical_bandwidth`, `tone_level`, `masking_level`, `tonality`,
`audibility_criterion`, `tonal_audibility`, `is_audible` and
`has_identified_tone`. When the candidate fails the 9.5.2 screening or no
line classifies as "tone", `has_identified_tone` is `False`: the numeric
fields are non-standard fallbacks and such spectra must be **excluded** from
the 9.5.1 energy averaging of $\Delta L_\mathrm{a}$ over the spectra of a wind-speed bin
(`is_audible` also requires an identified tone). The tone frequency and the
$L_\mathrm{a}$ criterion anchor to the highest classified tone line, not the probed
candidate. The audibility formula coincides with ISO 1996-2 Annex C; what is
specific to IEC 61400-11 is the determination of the tone and masking levels
and the Zwicker critical band from the spectrum. IEC 61400-11 stops at
$\Delta L_\mathrm{a}$ and prescribes no adjustment, so which mapping gives the rating
adjustment $K_\mathrm{t}$ depends on the edition the assessment is made under. The
9.5.1 energy average over the spectra of a wind-speed bin is a *mean*
audibility, which is the quantity ISO 1996-2:2017 Table J.1 was written for:
[`tonal_adjustment_from_mean_audibility`](https://docs.jmrp.io/phonometry/environment/assessment/environmental-levels/),
integer 0-6 dB (or `coarse=True` for the 0/3/6 ladder of its note). The
piecewise (C.4)-(C.6) law of `tonal_adjustment` is the 2007 Annex C mapping and
applies to one spectrum's $\Delta L_\mathrm{ta}$, and the two differ by 1 to 2 dB on
the same input: $\Delta L = 5$ dB gives $K_\mathrm{t} = 3$ by Table J.1 and 1.0 dB by
Annex C, $\Delta L = 9$ dB gives 4 dB and 5.0 dB. The notation differs too:
this page's $\Delta L_\mathrm{a}$ is that page's $\Delta L_\mathrm{ta}$, and the two printings
carry the criterion with opposite signs.

### Assessment report (`.report()`)

Tonal audibility is the part of a wind-turbine assessment that ends in a
document handed to a regulator, and the result writes that document:
`WindTurbineTonalityResult.report(path)` renders a one-page PDF fiche laid out
like the tonality assessment of an environmental-noise laboratory, following
**IEC 61400-11:2012+A1:2018** (subclauses 9.5.2 to 9.5.8): a standard-basis
line, an optional metadata header block (source/situation, client, measurement
position, instrumentation and date), a critical-band analysis table (tone
frequency, critical bandwidth, tone level $L_{p\mathrm{t}}$, masking-noise level
$L_{p\mathrm{n}}$, tonality $\Delta L_\mathrm{tn}$, audibility criterion $L_\mathrm{a}$ and tonal
audibility $\Delta L_\mathrm{a}$) beside the narrowband-spectrum plot with the critical
band, the masking level and the tone marked, the boxed tonal audibility
$\Delta L_\mathrm{a}$ together with the tone frequency and the audibility decision, an
optional PASS/FAIL verdict row and a note on how $\Delta L_\mathrm{a}$ is built, and a
footer with the fixed disclaimer.

It uses the same `ReportMetadata` container and rendering engine as the
[ISO 532-1 loudness fiche](https://docs.jmrp.io/phonometry/perception/psychoacoustics/loudness/#iso-532-1-report-report);
a supplied `requirement` is read as the maximum acceptable tonal audibility
$\Delta L_\mathrm{a}$ in dB (a less audible tone passes). Rendering needs reportlab and,
for the figure the fiche embeds, matplotlib (`pip install
"phonometry[report,plot]"`); only `engine="reportlab"` is supported. The fiche
renders in English by default; pass `language="es"` for a Spanish fiche
(translated fixed strings and a comma decimal separator), e.g.
`res.report("tonality_fiche_es.pdf", language="es")`.

```python
from phonometry import environment, ReportMetadata

# The 500 Hz gearbox tone over the flat 30 dB floor of the snippet above.
res = environment.wind_turbine_tonality(levels, frequencies=frequencies)
res.report(
    "tonality_fiche.pdf",
    metadata=ReportMetadata(
        specimen="Horizontal-axis wind turbine, gearbox tone",
        measurement_standard="IEC 61400-11",
        laboratory="Phonometry Reference Laboratory",
        requirement=6.0,            # maximum acceptable tonal audibility (dB)
    ),
)                                   # tonal audibility (dB) and the decision
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [IEC 61400-11 wind-turbine tonal audibility example report (PDF)](https://docs.jmrp.io/phonometry/media/iec61400_wind_turbine_tonality_example.pdf): One-page wind-turbine tonal-audibility fiche: a metadata header, a critical-band analysis table (tone frequency 500.0 Hz, critical bandwidth 117.3 Hz, tone level Lpt = 60.0 dB, masking-noise level Lpn = 45.9 dB, tonality ΔL_tn = 14.1 dB, audibility criterion La = -2.3 dB) beside the narrowband-spectrum plot with the critical band shaded and the masking level drawn, the boxed tonal audibility ΔL_a = 16.4 dB at the 500.0 Hz tone with the decision that the tone is audible, and a FAIL verdict against a maximum acceptable audibility of 6.0 dB.

Wind-turbine tonal-audibility fiche (WindTurbineTonalityResult.report), tonal audibility ΔL_a in dB with the audibility decision.

## What this guide covers

- **Covered.** The closed-form quantities of IEC 61400-11:2012+A1:2018: `slant_distance`
  (Formulae 1 and 2), `apparent_sound_power_level` (Formula 26) and the
  tonal-audibility chain of subclauses 9.5.2 to 9.5.8 through
  `wind_turbine_tonality`, with its `.report()` fiche. The Formula (29) mapping
  of a 10 m wind speed to hub height over $z_{0\mathrm{ref}} = 0.05$ m is
  `environment.logarithmic_wind_speed`, on the
  [receptor page](https://docs.jmrp.io/phonometry/environment/sources/wind-turbine-receptor/). The
  instrumentation and position requirements of clauses 6 and 7 are documented
  above as the conditions those formulae assume, and the measurement-position
  tolerances are drawn.

- **Not covered.** The measurement campaign itself: the 10 s averaging, the 0.5 m/s wind-speed
  binning with its 10 + 10 periods, the background correction, the interpolation
  to bin centres and the uncertainty budget of clause 9.3 all operate on whole
  campaigns and are the user's. The declaration route of IEC TS 61400-14, which turns a batch of
  measured machines into the single number a planning authority receives, is not
  implemented either. And two things a wind-turbine reader often arrives looking
  for are outside IEC 61400-11 altogether: **amplitude modulation** (the
  "swish", which is folded into $L_{W\mathrm{A}}$ and rated nowhere in this standard) and
  **infrasound**. Both are listed in 7.2.1 as *optional* measurements with no
  rating method attached. Amplitude modulation at a dwelling is rated by clause
  13 of IEC TS 61400-11-2, on the
  [receptor page](https://docs.jmrp.io/phonometry/environment/sources/wind-turbine-receptor/);
  infrasound falls to national guidance, and the psychoacoustic route to both
  starts at [Fluctuation strength and
  roughness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/) and at
  [Special weightings](https://docs.jmrp.io/phonometry/signals/levels/special-weightings/) for the
  G-weighted infrasound level.

## See also

- [Environmental noise levels](https://docs.jmrp.io/phonometry/environment/assessment/environmental-levels/): the ISO 1996-2 rating adjustment this page's $\Delta L_\mathrm{a}$ feeds.
- [Tone audibility](https://docs.jmrp.io/phonometry/perception/psychoacoustics/tone-audibility/): the same tonal-audibility idea outside the wind-turbine context.
- [Outdoor Sound Propagation](https://docs.jmrp.io/phonometry/environment/propagation/outdoor-propagation/): the chain that carries $L_{W\mathrm{A}}$ from the rotor to a dwelling.
- [Wind turbine sound at a dwelling](https://docs.jmrp.io/phonometry/environment/sources/wind-turbine-receptor/): IEC TS 61400-11-2, what arrives at the receptor, with its amplitude modulation rating and the low frequency level indoors.
- API reference: [`environment.sources.wind_turbine`](https://docs.jmrp.io/phonometry/reference/api/environment/wind-turbine/).

## References

- **International Electrotechnical Commission. (2005).** [*Wind turbines — Part 14: Declaration of apparent sound power level and tonality values*](https://webstore.iec.ch/en/publication/5432) (IEC TS 61400-14:2005).
  How a manufacturer turns IEC 61400-11 measurements of a batch of turbines into declared values with a stated uncertainty, the number a planning authority actually receives.
- **International Electrotechnical Commission. (2018).** [*Wind turbines — Part 11: Acoustic noise measurement techniques*](https://webstore.iec.ch/en/publication/63367) (IEC 61400-11:2012+AMD1:2018 CSV).
  The implemented edition: the measurement geometry and the tonal-audibility chain (apparent sound power Formula 26, critical bandwidth Formula 30, masking level Formula 31, tonality/audibility Formulae 32-34). The full measurement pipeline, with its wind-speed binning, its regression to standardised wind speeds and its uncertainty budgets, is out of scope here.
- **International Organization for Standardization. (2017).** [*Acoustics — Description, measurement and assessment of environmental noise — Part 2: Determination of sound pressure levels*](https://www.iso.org/standard/59766.html) (ISO 1996-2:2017).
  The tonal-audibility criterion the IEC method reuses comes from the Annex C of its 2007 edition (the 2017 edition carries the tonal methods in Annexes J and K), and its Table J.1 mapping, tonal_adjustment_from_mean_audibility, is the one that consumes the bin-mean audibility.