# Spherical ground effect and advanced barriers

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/environment/propagation/ground-barriers/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/environment/propagation/ground-barriers/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-18
Updated: 2026-11-16T21:36:14Z
Standards: EN 1793-1:2012; EN 1793-2:2012; EN 1793-3:1997; EN 16272-3-1:2012
Verified: 10 conformance checks (EN 1793-1:2012; EN 1793-2:2012; EN 1793-3:1997; EN 16272-3-1:2012) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Weyl-Van der Pol spherical-wave reflection over finite-impedance ground and wave-theory diffraction: Kurze-Anderson, rigid half-plane, thick barriers.

---

The [ISO 9613-2 general method](https://docs.jmrp.io/phonometry/environment/propagation/outdoor-propagation/) folds
the ground and barrier terms into tabulated, energy-based corrections. This page
covers the underlying wave acoustics in
`phonometry.environment.propagation.ground_barriers`: the **spherical-wave reflection
coefficient** of a finite-impedance ground (Weyl-Van der Pol) and the
**wave-theoretic diffraction** of a screen, both in a homogeneous
(non-refracting, non-turbulent) atmosphere. These are the physical core of the
Nord2000 / CNOSSOS ground and barrier models, and they resolve the
frequency-dependent interference structure the octave-band $A_\mathrm{gr}$/$D_z$
terms smooth away.

## 1. Spherical-wave ground effect (Weyl-Van der Pol)

The sound field of a point source above a locally reacting ground is the sum of
a direct wave and a reflected wave weighted by the **spherical-wave reflection
coefficient** $Q$ (Attenborough Eq. 2.40a; Salomons Eq. 3.2):

$$
p = \frac{\mathrm{e}^{ikR_1}}{4\pi R_1} + Q\,\frac{\mathrm{e}^{ikR_2}}{4\pi R_2},
$$

with $R_1$ the source-receiver distance and $R_2$ the image-source distance.
The coefficient (Attenborough Eq. 2.40c; Salomons Eq. D.58) corrects the
plane-wave coefficient $R_\mathrm{p}$ for the curvature of the wavefront:

$$
Q = R_\mathrm{p} + (1 - R_\mathrm{p})\,F(w), \qquad
R_\mathrm{p} = \frac{Z\cos\theta - 1}{Z\cos\theta + 1},
$$

$$
F(w) = 1 + i\sqrt{\pi}\,w\,\mathrm{e}^{-w^2}\operatorname{erfc}(-iw), \qquad
w = \sqrt{\tfrac{i k R_2}{2}}\left(\cos\theta + \tfrac{1}{Z}\right).
$$

Here $Z$ is the ground surface impedance normalized by $\rho c$, $\theta$ is
the angle of incidence from the ground normal
($\cos\theta = (h_\mathrm{s} + h_\mathrm{r})/R_2$), and the boundary-loss factor $F(w)$ is
written through the scaled complementary error function
$\mathrm{e}^{-w^2}\operatorname{erfc}(-iw)$, i.e. the Faddeeva function
`scipy.special.wofz`. The second term of $Q$ is the *ground wave* that keeps
the field finite at grazing incidence, where $R_\mathrm{p} \to -1$ and a plane-wave
model would predict silence
(Salomons Eqs. D.57, D.59, D.60).

The relative sound level (the *excess attenuation*, dB re free field) is
(Salomons Eq. 3.4):

$$
\Delta L = 20\log_{10}\!\left|\,1 + Q\,\frac{R_1}{R_2}\,\mathrm{e}^{i k (R_2 - R_1)}\,\right|.
$$

```python
import numpy as np
from phonometry import environment

bands = np.array([63., 125., 250., 500., 1000., 2000., 4000., 8000.])

# Grassland (effective flow resistivity sigma = 200 kPa.s/m^2), source 1 m and
# receiver 1.5 m high, 50 m apart. The impedance comes from the Delany-Bazley
# porous model of phonometry.materials (a semi-infinite ground).
# Argument order: frequencies, source_height_m, receiver_height_m, distance.
res = environment.ground_effect(bands, 1.0, 1.5, 50.0, flow_resistivity_pa_s_m2=2e5)
print(res.excess_attenuation)     # the ground dip (dB re free field)
print(res.reflection_coefficient) # complex Q per band
res.plot()                        # excess attenuation vs frequency
```

The ground impedance is either derived from an effective `flow_resistivity_pa_s_m2`
(via the `delany_bazley` or `miki` model of
[`phonometry.materials`](https://docs.jmrp.io/phonometry/materials/absorbers/porous-absorbers/), which model a
semi-infinite porous ground) or supplied directly as a normalized complex
`impedance` (a scalar, per-band array, or a `PorousMediumResult`). A plain
`impedance` value is taken in the $\mathrm{e}^{-i\omega t}$ convention of Salomons, in
which a passive ground has $\operatorname{Im}(Z) > 0$; the porous models of
`phonometry.materials` work in the opposite $\mathrm{e}^{+j\omega t}$ convention
($\operatorname{Im}(Z) < 0$), so anything obtained
from them (a `flow_resistivity_pa_s_m2` or a `PorousMediumResult`) is conjugated
internally before it enters the Weyl-Van der Pol formulas.

![Excess attenuation (level re free field) against frequency on a log axis for four ground types. Fresh snow (10 kPa s/m2) dips deepest and lowest in frequency, near minus 18 dB around 150 Hz; forest floor (50 kPa s/m2) reaches about minus 15 dB near 290 Hz and grassland (200 kPa s/m2) about minus 12 dB near 540 Hz; asphalt (20000 kPa s/m2) hugs the plus 6 dB hard-ground enhancement limit until a deep dip near 2.4 kHz. A dotted line marks the plus 6 dB hard-ground limit and a solid line the 0 dB free field](https://docs.jmrp.io/phonometry/media/ground_effect_spherical.svg)

*Softer ground means a deeper dip at a lower frequency: the dip tracks the
effective flow resistivity across more than a decade, and only asphalt stays
near the +6 dB hard-ground limit across the speech range. Note the unit: the
flow resistivity is a resistivity in Pa·s/m², not a pressure.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import environment

freqs = np.geomspace(50.0, 4000.0, 400)
grounds = [
    ("Fresh snow (10 kPa·s·m⁻²)", 10e3, "#2ca02c"),
    ("Forest floor (50 kPa·s·m⁻²)", 50e3, "#9467bd"),
    ("Grassland (200 kPa·s·m⁻²)", 200e3, "#1f77b4"),
    ("Asphalt (20 000 kPa·s·m⁻²)", 20000e3, "#d62728"),
]
fig, ax = plt.subplots(figsize=(11, 6.4))
for label, sigma, color in grounds:
    res = environment.ground_effect(freqs, 1.0, 1.5, 50.0, flow_resistivity_pa_s_m2=sigma)
    ax.plot(freqs, res.excess_attenuation, color=color, label=label)
ax.axhline(6.0, color="k", ls=":", label="Hard-ground limit (+6 dB)")
ax.axhline(0.0, color="k", lw=0.8)
ax.set_xscale("log")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Level re free field [dB]")
ax.legend()
plt.show()
```

**Limits reproduced by the implementation** (each a pinned test or conformance
anchor): an acoustically hard ground ($|Z| \to \infty$) gives $R_\mathrm{p} \to 1$,
$|w| \to 0$, $F \to 1$ and $Q \to 1$, so $\Delta L$ reaches +6 dB in phase;
the effective flow resistivity $\sigma \to \infty$ tends to that hard ground;
grazing incidence ($h_\mathrm{s}, h_\mathrm{r} \to 0$) gives $R_\mathrm{p} \to -1$; and the ground
effect is reciprocal under an exchange of source and receiver heights.

The ground wave is easiest to see by taking the geometry towards grazing and
watching $R_\mathrm{p}$ and $Q$ come apart.

![Two panels against source and receiver height falling from 3 m to 0.02 m at 50 m range and 500 Hz over grassland. Left: the magnitude of the plane-wave reflection coefficient Rp rising to 1 while its phase runs to 180 degrees, and the magnitude of the spherical-wave coefficient Q departing upward from it and settling near 1.26, with the magnitude of the boundary-loss factor F(w) on a second axis. Right: the excess attenuation computed with Q, which flattens near minus 12 dB, against the same quantity computed with Rp alone, which falls through minus 40 dB towards the silence a plane-wave model predicts at grazing incidence](https://docs.jmrp.io/phonometry/media/ground_reflection_coefficient.svg)

*At 3 m of height the two coefficients agree to within a few per cent and the
ground wave is irrelevant. By 0.02 m, $R_\mathrm{p}$ has reached $-1$ (magnitude 0.993 at
179.6°) and a plane-wave model predicts $-40.1$ dB, near silence. The spherical
coefficient reaches $|Q| = 1.26$ instead and the field settles at $-11.9$ dB.
That 28 dB is what the Faddeeva term $F(w)$ buys, and it is why a grazing outdoor
path is audible at all.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `ground_effect` is imported by the snippet above.
heights = np.geomspace(3.0, 0.02, 60)
c0, f, d = 343.0, 500.0, 50.0
k = 2 * np.pi * f / c0
q_mag, rp_mag, dl_q, dl_p = [], [], [], []
for h in heights:
    res = environment.ground_effect([f], h, h, d, flow_resistivity_pa_s_m2=2e5, model="miki")
    rp = res.plane_reflection_coefficient[0]
    q = res.reflection_coefficient[0]
    phase = np.exp(1j * k * (float(res.r_reflected) - float(res.r_direct)))
    ratio = float(res.r_direct) / float(res.r_reflected)
    rp_mag.append(abs(rp))
    q_mag.append(abs(q))
    dl_q.append(20 * np.log10(abs(1 + q * ratio * phase)))
    dl_p.append(20 * np.log10(abs(1 + rp * ratio * phase)))

fig, (left, right) = plt.subplots(1, 2, figsize=(11, 4.6))
left.semilogx(heights, rp_mag, label="|Rp| (plane wave)")
left.semilogx(heights, q_mag, label="|Q| (spherical wave)")
left.invert_xaxis()
left.set(xlabel="Source = receiver height [m]", ylabel="Magnitude")
left.legend()
right.semilogx(heights, dl_q, label="with Q")
right.semilogx(heights, dl_p, label="with Rp only")
right.invert_xaxis()
right.set(xlabel="Source = receiver height [m]",
          ylabel="Level re free field [dB]")
right.legend()
plt.show()
```

### Choosing the ground impedance

Both one-parameter models are being evaluated far **below** their published fit
range for any outdoor ground, and the `PorousAbsorberWarning` these calls raise
says so: the range is $0.01 < X < 1$ with $X = \rho_0 f/\sigma$, and the
grassland above sits at $X = 3.8\times10^{-4}$ at 63 Hz and 0.024 at 4 kHz;
the asphalt curve of the figure never enters the range at all. Below the range the
Delany-Bazley regression is an extrapolation whose classic failure is a negative
real part of the surface impedance; **Miki** is the passivity-constrained refit
to prefer there (see the fit-range paragraph of
[Porous absorbers](https://docs.jmrp.io/phonometry/materials/absorbers/porous-absorbers/)). The
choice is not cosmetic: on the case above, `model="miki"` moves the excess
attenuation by up to 3.6 dB (250 Hz band: 0.43 dB with Delany-Bazley,
−3.18 dB with Miki).

Typical **effective** flow resistivities, the ranges the figure above
illustrates: fresh snow ≈ 10, forest floor ≈ 50, grassland and pasture
≈ 150-300, compacted soil and gravel ≈ 1000-3000, asphalt and
concrete > 20 000 kPa·s/m².

For a real site, fit $\sigma$ to a short-range level-difference measurement
between two microphone heights over the surface (the template method of
ANSI/ASA S1.18). The fitted value is an *effective, model-bound* parameter: it
must be quoted with the impedance model it was fitted with, and it is not the
EN 29053 airflow resistivity of the same material.

### A ground from a catalogue

A row of `environment.PUBLISHED_GROUND_SURFACES`, or of [a catalogue of your own](https://docs.jmrp.io/phonometry/io/material-catalogues/),
gives the impedance itself: `GroundSurface.medium` is the porous half-space
of its effective flow resistivity, by the Delany and Bazley or the Miki
model, which `ground_effect` takes as `impedance`, `barrier_insertion_loss`
as `ground_impedance` and `atmospheric_parabolic_equation` as `impedance`.
The resistivity is read through `printed()`, so a row that prints a range
is refused rather than averaged, and, because the fitted value is
model-bound, a row the page marks as fitted with one model goes into that
model only. Harmonoise class D, $\sigma$ = 200 kPa·s/m², gives the Miki
curve of the case above:

```python
octaves = [125.0, 250.0, 500.0, 1000.0]
pasture = environment.PUBLISHED_GROUND_SURFACES["bies-2017-table-5-2/normal_uncompacted_ground"]
ground = pasture.medium(octaves, model="miki")
over_pasture = environment.ground_effect(octaves, 1.0, 1.5, 50.0, impedance=ground)
print(over_pasture.excess_attenuation.round(2))   # [  3.84  -3.18 -13.19  -2.96]

field = environment.PUBLISHED_GROUND_SURFACES["cox-2017-table-6-7/sports_field_delany_bazley"]
try:
    field.medium(octaves, model="miki")
except ValueError as error:
    print(error)
# 'Sports field' is the row the page marks “Fitted using Delany and Bazley
# model” (Cox & D'Antonio 3e Table 6.7, PDF pages 257-258 (printed pp.
# 200-201)): its effective flow resistivity is a parameter of that model and
# not of 'miki'; ask for model='delany_bazley', or take
# row.printed('flow_resistivity_pa_s_m2') into another model yourself.
```

## 2. Advanced barrier diffraction

Three levels of screening beyond the ISO 9613-2 $D_z$ term are provided by
`barrier_insertion_loss` and its building blocks.

**Kurze-Anderson closed form.** The insertion loss of a thin screen as a
function of the Fresnel number $N = (2/\lambda)(A + B - d)$ (Bies Eq. 5.134,
with $A$ and $B$ the two segments of the shortest source-edge-receiver path
and $d$ the straight distance) is (Bies Eq. 5.138; Kurze & Anderson 1971):

$$
\Delta = 5 + 20\log_{10}\!\left(\frac{\sqrt{2\pi N}}{\tanh\sqrt{2\pi N}}\right)\;\text{dB},
$$

which tends to 5 dB at the shadow boundary $N \to 0$ and approximates Maekawa's
point-source curve within about 1.5 dB.

The clip below is that formula as a field. It is the
[2D FDTD solver](https://docs.jmrp.io/phonometry/simulation/fdtd-simulation/) run twice on one
12 × 7 m half-space over rigid ground with a thin rigid screen 2.5 m tall,
once at 100 Hz and once at 500 Hz, each with a barrier-free reference run over
the same ground so the annotated insertion loss is a true one. The geometry
fixes the path difference at 1.06 m for the receiver it marks, so the Fresnel
number is $N = 0.62$ at 100 Hz and $N = 3.1$ at 500 Hz (the same screen, a
factor of five apart in $N$ purely because $\lambda$ changed), and the field
shows what that buys: about 8 dB against about 17 dB. Two things are worth
watching for. The edge of the lit region running down from the top of the
screen is the shadow boundary, the $N \to 0$ locus where the formula bottoms
out at 5 dB; and inside the shadow the field is a cylindrical wave centred on
the top of the screen, which is what "the edge acts as a secondary source"
looks like. One caveat: the ground in the clip is perfectly rigid, so it shows
diffraction alone and none of the finite-impedance ground effect of section 1;
the coherent four-path model below adds that, and its curve swings tens of
decibels where this one is smooth.

**Video:** [Barrier diffraction at 100 Hz and 500 Hz (2D FDTD)](https://docs.jmrp.io/phonometry/media/anim_fdtd_barrier.webm): A 2D FDTD simulation of a point source behind a thin 2.5 metre rigid barrier on reflecting ground, at 100 Hz and 500 Hz side by side. The long wavelength diffracts over the edge and fills the shadow zone with an insertion loss near 8 dB, while the short wavelength is cast into a deep clean shadow of about 17 dB.

The thin-screen methods share the same three geometric quantities: the two
diffracted segments over the edge and the straight path they replace. Drawn on
the 4 m screen of the snippets, they differ by just 0.15 m.

![Section of the barrier geometry: a loudspeaker source 1 m above the ground, a thin 4 m screen at 50 m and a microphone receiver 1.5 m high at 100 m, the blocked direct path of 100.00 m drawn dashed through the screen and the diffracted path bent over the edge in two segments A = 50.09 m and B = 50.06 m, with the resulting path difference of 0.15 m giving a Fresnel number of 0.44 and a Kurze-Anderson insertion loss of 10.0 dB at 500 Hz, rising to 15.5 dB at 2 kHz](https://docs.jmrp.io/phonometry/media/diagram_ground_barrier.svg)

```python
from phonometry import environment

environment.kurze_anderson_attenuation(0.0)     # 5.0 dB at the shadow boundary

# A 4 m barrier 50 m from a 1 m source, receiver 1.5 m high at 100 m.
il = environment.barrier_insertion_loss(bands, 1.0, 50.0, 4.0, 100.0, 1.5,
                                        method="kurze_anderson")
il.plot()                           # insertion loss vs frequency
```

**Exact rigid half-plane.** With `method="exact"` the wave-theoretic insertion
loss of a rigid thin screen is used: the compact Fresnel-integral form of the
MacDonald / Hadden & Pierce solution (Attenborough Eqs. 9.19-9.20), built from
the auxiliary Fresnel functions. It gives 6 dB at the shadow boundary (the
field is exactly halved, the flat-wedge limit) and tracks Kurze-Anderson through
the shadow zone.

**Thick barriers.** A `thickness_m` (top width $e$) moves the second diffraction
edge downstream and lengthens the diffracted path to $A + e + B$, the double-edge
Fresnel number $N = (2/\lambda)(A + B + e - d)$ of Bies Eq. 5.157. The
improvement is monotone but it is small, and the reason is geometric: $B$ is now
measured from the *far* edge, so most of what the top width adds it also gives
back. On the 4 m screen of this page, a 4 m top width is worth **0.08 dB** at
500 Hz and 0.14 dB at 8 kHz; even 30 m of width only reaches 1.2 dB.

![Two panels on what a thick barrier buys over a thin screen of the same height, for a 4 m barrier 50 m from a 1 m source with the receiver 1.5 m high at 100 m. Left: the insertion-loss gain over the thin screen against top width from 0 to 30 m at 250 Hz, 500 Hz and 1 kHz, staying below 1.5 dB across the whole sweep. Right: the same comparison run through the ISO 9613-2 screening term, where the double-diffraction factor C3 adds several decibels for the same widths, with the difference between the two answers annotated](https://docs.jmrp.io/phonometry/media/barrier_thickness_gain.svg)

*The path-length effect alone is worth a fraction of a decibel at road-traffic
distances. ISO 9613-2 credits a well-separated double edge with a separate
factor $C_3$ that rises from 1 towards 3, worth up to $10\log_{10}3 \approx
4.8$ dB, which the wave-theoretic model here does not include: for the same 4 m
top width $D_z$ goes from 7.6 dB to 9.0 dB at 500 Hz. Neither number licenses
building a berm and expecting the ISO bonus from this page's model.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `barrier_insertion_loss` is imported by the snippet above.
widths = np.linspace(0.0, 30.0, 40)
fig, ax = plt.subplots()
for freq in (250.0, 500.0, 1000.0):
    thin = float(environment.barrier_insertion_loss(
        [freq], 1.0, 50.0, 4.0, 100.0, 1.5, method="exact").insertion_loss[0])
    gain = [0.0 if e == 0.0 else float(environment.barrier_insertion_loss(
        [freq], 1.0, 50.0, 4.0, 100.0, 1.5, method="exact",
        thickness_m=e).insertion_loss[0]) - thin for e in widths]
    ax.plot(widths, gain, label=f"{freq:g} Hz")
ax.set_xlabel("Top width e [m]")
ax.set_ylabel("Gain over the thin screen [dB]")
ax.legend()
plt.show()
```

**Coherent barrier on the ground.** With a `ground_impedance` (or a
`ground_flow_resistivity_pa_s_m2`) the four source-image / receiver-image diffracted
paths are combined coherently, each ground reflection weighted by the
spherical-wave coefficient $Q$ above (Attenborough Ch. 9; Bies Sec. 5.3.5).
This exposes the ground-barrier interference structure that a purely energetic
sum of $A_\mathrm{gr}$ and $D_z$ cannot. As a first-order simplification a single
$Q$ (over the
overall source-receiver geometry) weights every bounce rather than a separate
coefficient per image path; the model is coherent and reciprocal but not a full
boundary-element solution.

![To-scale section of the coherent four-path barrier model: a source 1 m above the ground with its mirror image 1 m below, a 4 m screen at 50 m, and a receiver 1.5 m high at 100 m with its own mirror image below the ground. Four diffracted routes are drawn in four distinguishable strokes from the source or its image over the top edge to the receiver or its image, each labelled with the number of ground bounces and with the spherical reflection coefficient Q marked at every bounce; a side panel lists the four path lengths and the path-length differences that set the interference, and an inset repeats the two-edge geometry of a thick barrier with its top width e](https://docs.jmrp.io/phonometry/media/diagram_barrier_four_paths.svg)

```python
il = environment.barrier_insertion_loss(bands, 1.0, 50.0, 4.0, 100.0, 1.5,
                                        method="exact", ground_flow_resistivity_pa_s_m2=2e5)
il.ground        # True: the four-path coherent ground model was applied
il.plot()
```

The three models side by side on the same geometry tell the whole story: the
Kurze-Anderson fit and the exact half-plane track each other to within about
1.5 dB across two decades of Fresnel number, while the coherent ground model
swings tens of decibels around them, up where the barrier removes the
ground-effect dip of the unscreened path, down where the four diffracted paths
interfere destructively.

![Barrier insertion loss against frequency on a log axis for a 4 m screen between a 1 m source at 50 m and a 1.5 m receiver at 100 m. The dashed Kurze-Anderson curve and the solid exact rigid half-plane curve rise together from about 6 dB at 50 Hz to 19 dB at 5 kHz, never more than about 1.5 dB apart; the coherent four-path ground curve oscillates around them, peaking above 45 dB near 230 Hz where the unscreened ground dip is removed and falling below minus 10 dB near 550 Hz, with the dotted Kurze-Anderson 5 dB grazing-limit line underneath](https://docs.jmrp.io/phonometry/media/barrier_insertion_loss_methods.svg)

*The two thin-screen models never separate by more than about 1.5 dB, so the
choice between them barely matters. The coherent ground curve is a different
kind of object: it swings from above +45 dB near 230 Hz, where the barrier
removes the unscreened path's own ground dip, to below −10 dB near 550 Hz, where
the four diffracted paths cancel. Both extremes are narrowband and neither is a
design value.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import environment

# The 4 m barrier of the snippets above, on a fine frequency grid.
freqs = np.geomspace(50.0, 5000.0, 240)
il_ka = environment.barrier_insertion_loss(freqs, 1.0, 50.0, 4.0, 100.0, 1.5,
                                           method="kurze_anderson")
il_ex = environment.barrier_insertion_loss(freqs, 1.0, 50.0, 4.0, 100.0, 1.5,
                                           method="exact")
il_gr = environment.barrier_insertion_loss(freqs, 1.0, 50.0, 4.0, 100.0, 1.5,
                                           method="exact", ground_flow_resistivity_pa_s_m2=2e5)
fig, ax = plt.subplots(figsize=(11, 6.4))
ax.semilogx(freqs, il_ka.insertion_loss, "--", label="Kurze-Anderson (thin screen)")
ax.semilogx(freqs, il_ex.insertion_loss, label="Exact rigid half-plane")
ax.semilogx(freqs, il_gr.insertion_loss, label="Exact + coherent ground (four paths)")
ax.axhline(5.0, color="k", ls=":", label="Kurze-Anderson grazing limit (5 dB)")
ax.set(xlabel="Frequency [Hz]", ylabel="Insertion loss [dB]")
ax.legend()
plt.show()
```

All three curves share the same base geometry, and `.plot_geometry()` draws
it to scale: at these road-traffic distances the 4 m screen is a sliver. For
the thin-screen curves the 0.15 m path difference combines with wavelength in
the Fresnel number; the coherent-ground curve also depends on ground
impedance and image-path interference.

![To-scale section of the barrier geometry of the insertion-loss curves: a source star 1 m above the hatched ground, a thin 4 m screen at 50 m, and a receiver triangle 1.5 m high at 100 m, with the dashed direct path cut by the screen, the solid diffracted path bent over its top edge, the path difference of 0.15 m annotated and the 50 m and 100 m distances dimensioned](https://docs.jmrp.io/phonometry/media/barrier_geometry.svg)

*Drawn to scale the screen almost vanishes: the diffracted path over the top
is only 0.15 m longer than the blocked direct path, and that difference is
the geometric input of the Fresnel number $N = (2/\lambda)(A + B - d)$ that the
thin-screen methods above key on.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import environment

freqs = np.geomspace(50.0, 5000.0, 240)
il = environment.barrier_insertion_loss(freqs, 1.0, 50.0, 4.0, 100.0, 1.5)

# One line: the section to scale, with the path-length difference annotated.
il.plot_geometry()
plt.show()
```

### `ground_effect()` and `barrier_insertion_loss()` parameters

Both entry points take their distances **along the ground from the source**, and
neither takes a distance from the barrier. That is the trap worth naming: in
`barrier_insertion_loss(bands, 1.0, 50.0, 4.0, 100.0, 1.5)` the receiver is
100 m from the *source*, i.e. 50 m past the screen, not 100 m past it. The two
functions also spell the same option differently (`model=` on `ground_effect`,
`ground_model=` on `barrier_insertion_loss`) and order their geometry
differently, which is why the two positional calls on this page are not
parallel.

| `ground_effect` parameter | Type / shape | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `frequencies` | scalar or 1D array | Hz | > 0 | Narrowband: no band smoothing |
| `source_height_m` | float | m | ≥ 0 | $h_\mathrm{s}$ |
| `receiver_height_m` | float | m | ≥ 0 | $h_\mathrm{r}$ (**before** the distance) |
| `distance` | float | m | > 0 | Horizontal source-receiver distance |
| `impedance` | array, `PorousMediumResult` or None | — | `None` | Normalized $Z$ in the $\mathrm{e}^{-i\omega t}$ convention |
| `flow_resistivity_pa_s_m2` | float or None | Pa·s/m² | `None` | Effective $\sigma$; feeds the porous model |
| `model` | `"delany_bazley"` \| `"miki"` | — | `"delany_bazley"` | Prefer `"miki"` below the fit range |
| `speed_of_sound` / `air_density` | float | m/s, kg/m³ | 343.0 / 1.205 | |

| `barrier_insertion_loss` parameter | Type / shape | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `frequencies` | scalar or 1D array | Hz | > 0 | |
| `source_height_m` | float | m | ≥ 0 | $h_\mathrm{s}$ |
| `barrier_distance` | float | m | > 0 | Source to the (near) edge, along the ground |
| `barrier_height_m` | float | m | > 0 | Edge height above the ground |
| `receiver_distance` | float | m | > `barrier_distance` (+ `thickness_m`) | Measured **from the source** |
| `receiver_height_m` | float | m | ≥ 0 | $h_\mathrm{r}$ (**after** the distance) |
| `method` | `"kurze_anderson"` \| `"exact"` | — | `"exact"` | `"exact"` is the rigid half-plane |
| `thickness_m` | float or None | m | `None` | Top width $e$; double edge |
| `ground_impedance` | array, `PorousMediumResult` or None | — | `None` | Selects the coherent four-path model |
| `ground_flow_resistivity_pa_s_m2` | float or None | Pa·s/m² | `None` | Same, from an effective $\sigma$ |
| `ground_model` | `"delany_bazley"` \| `"miki"` | — | `"delany_bazley"` | Note the name: not `model=` |
| `speed_of_sound` / `air_density` | float | m/s, kg/m³ | 343.0 / 1.205 | |

A ground argument requires `method="exact"`; `method="kurze_anderson"` with a
ground raises `ValueError`.

### Choosing a model, and what none of them models

**Which one to use.** Kurze-Anderson for an octave-band engineering estimate,
where its ±1.5 dB against the exact solution is far inside the uncertainty of
everything else in the chain. The exact rigid half-plane when the behaviour near
the shadow boundary matters (it gives 6 dB there against Kurze-Anderson's 5 dB,
and the 6 dB is the physically correct halved field). The coherent four-path
model only when the narrowband interference structure is the question: never
raw as a design value.

**The coherent curve must be averaged before it means anything.** It is a
coherent, narrowband, fully deterministic result. Real atmospheric turbulence
decorrelates the four paths, a real source has bandwidth, and a real receiver
moves; all three wash out the extremes. A +45 dB narrowband insertion loss is
not a barrier that removes 45 dB, it is a frequency at which the *unscreened*
path happened to sit in its own ground dip. Band-average the curve, or read it
as structure rather than as a level.

**All four models are two-dimensional endless screens.** A real barrier of
finite length lets sound flank around its ends, and two parallel barriers either
side of a road reflect between each other and lose several decibels of their
nominal performance. Neither effect exists in any model on this page.

**Diffraction is the screening limit, not the realised one.** The insertion loss
a built barrier delivers is the smaller of the diffraction result and the
transmission loss of the panel itself, and the obstacle has to qualify as a
barrier in the first place: surface density, a closed surface, and a horizontal
extent normal to the path larger than the wavelength. Those qualifying rules are
stated in the
["Barrier pitfalls" section of Outdoor Sound Propagation](https://docs.jmrp.io/phonometry/environment/propagation/outdoor-propagation/);
they apply here unchanged.

## 3. What the product declaration says (EN 1793)

Everything above is the barrier as physics. A barrier on sale is a product, and
what its declaration carries is two integers, neither of them a diffraction:
how much of the sound reaching it comes back across the road, and how much of
it goes through. Both are weighted by a spectrum nobody measures on site, the
**normalised traffic noise spectrum** of EN 1793-3: eighteen one-third octave
bands from 100 Hz to 5 kHz, peaking at 1 kHz and twelve decibels down at either
end.

![Three panels over the eighteen one-third octave bands of EN 1793-3. Left: the normalised traffic noise spectrum of EN 1793-3 as bars, running from minus twenty decibels at 100 Hz up to a minus eight decibel peak at 1 kHz and back down to minus eighteen at 5 kHz, with an annotation saying the peak carries the rating, and over them the normalised railway noise spectrum of EN 16272-3-1 as a marker line, lower at 100 Hz and flat from 1.25 to 2.5 kHz where the road one is already falling. Middle: the sound absorption coefficient of two devices, an absorptive cassette rising from 0.15 to 0.98 around 400 Hz and easing to 0.70, rating DL alpha 8 decibels in category A3, and a concrete panel flat at 0.05 rating 0 decibels in category A1. Right: the sound reduction index of two devices, a concrete panel rising from 30 to 53 decibels and rating DL R 42 decibels in category B4, and a metal cassette rising from 21 to 34 decibels and rating 29 decibels in category B3.](https://docs.jmrp.io/phonometry/media/road_device_ratings.svg)

*The weighting on the left decides everything, and there are two of them: a road
device is judged by what it does around 1 kHz, a railway one by what it does
between 1.25 and 2.5 kHz.*

**EN 1793-1** rates absorption as the energy the device does *not* send back:

$$
DL_\alpha = -10 \lg\left| 1 -
\frac{\sum_{i=1}^{18} \alpha_{\mathrm{S}i}\, 10^{0.1 L_i}}
     {\sum_{i=1}^{18} 10^{0.1 L_i}} \right|
$$

A reverberation-room $\alpha_\mathrm{S}$ can pass one band by band, which would
push the weighted ratio past 1 and leave the logarithm without an argument.
Clause 5 says so and fixes it: the ratio is limited to 0.99, so no device can
rate above 20 dB however absorptive it measures. `sound_absorption_rating`
warns when that limit is what answered instead of the measurement.

**EN 1793-2** rates airborne insulation with the same weighting, on the
transmitted energy instead:

$$
DL_R = -10 \lg\left|
\frac{\sum_{i=1}^{18} 10^{0.1 L_i}\, 10^{-0.1 R_i}}
     {\sum_{i=1}^{18} 10^{0.1 L_i}} \right|
$$

```python
from phonometry import environment

# A cassette with mineral wool behind a perforated face, in the eighteen
# one-third octave bands of EN 1793-3 from 100 Hz to 5 kHz.
absorption = [0.15, 0.25, 0.40, 0.60, 0.80, 0.95, 0.98, 0.95, 0.92,
              0.90, 0.88, 0.85, 0.82, 0.80, 0.78, 0.75, 0.72, 0.70]
reduction = [21.0, 22.0, 23.0, 24.0, 25.0, 26.0, 27.0, 28.0, 29.0,
             30.0, 31.0, 31.0, 32.0, 32.0, 33.0, 33.0, 34.0, 34.0]

absorbed = environment.sound_absorption_rating(absorption)
print(absorbed.reported, absorbed.category)     # 8 A3

through = environment.airborne_insulation_rating(reduction)
print(through.reported, through.category)       # 29 B3
```

Both are reported rounded to the nearest integer (EN 1793-1 Clause 6.1,
EN 1793-2 Clause 7.1), and each has a normative ladder in its Annex A read off
that integer: A1 to A5 for absorption, B1 to B4 for insulation, with A0 and B0
reserved for "not determined". The ladders have no gaps between their steps
because the number they classify is already an integer.

The two are not comparable and a declaration carries both. A plain concrete
panel reflects almost everything across the road and is still the better wall;
an absorptive cassette that keeps the reflection down can be the weaker one.
Which of the two matters is a question about the site, not about the product:
absorption for a road in a cutting or between parallel barriers, insulation for
whatever is directly behind.

### The same two numbers beside a railway

A barrier beside a track is rated the same way and against a different noise.
**EN 16272-3-1:2012** prints the normalised railway noise spectrum over the
same eighteen bands, and its Clauses 5 and 6 are the two formulas above with
that table in the weights. Rolling noise sits higher up than a road: the
railway spectrum is flat within a decibel from 1.25 kHz to 2.5 kHz, where the
road one has already begun to fall away, so an absorber that improves with
frequency is worth more beside a track than beside a road.

```python
from phonometry import environment

# A thick porous absorber, still improving where rolling noise is loudest.
absorption = [0.10, 0.15, 0.22, 0.32, 0.45, 0.60, 0.72, 0.82, 0.88,
              0.92, 0.95, 0.96, 0.96, 0.95, 0.94, 0.93, 0.92, 0.90]

road = environment.sound_absorption_rating(absorption)
rail = environment.sound_absorption_rating(absorption, spectrum="railway")
print(road.reported, rail.reported)          # 8 10
print(road.category, rail.category)          # A3 None
```

The railway parts print no category ladder: their annexes are guidance notes
on using the rating, so a railway rating is the number and nothing more, and
the result says so by carrying `None` where a road device carries its letter.
Clause 6 also carries a slip worth knowing about, since it changes what a
reader goes looking for: it says the sound reduction indices are weighted by
"the normalised traffic noise spectrum defined in Table 1", while Table 1 of
that standard is the railway spectrum and the symbol list under the formula
says railway. It is the road wording of EN 1793-2, left in place when the
clause was copied.

### The reflection, measured where the barrier stands

Both road numbers come from a laboratory, on a sample and in a diffuse field.
EN 1793-5 measures the reflection of the barrier as built, in the direct field
of a loudspeaker in front of it, and weights it by the same spectrum into a
third number, $DL_{RI}$. It has its own page, [Sound reflection of a noise
barrier in situ](https://docs.jmrp.io/phonometry/environment/propagation/barrier-reflection/), because most of the work is in getting from nine
impulse responses to the index; the rating itself is
`environment.sound_reflection_rating`, beside the two above, and returns the
same `RoadDeviceRating`.

## Relation to ISO 9613-2

The Kurze-Anderson insertion loss written $\Delta$ here is the same quantity
ISO 9613-2 calls $D_z$, and the two diffracted segments called $A$ and $B$ here
are its $d_\mathrm{ss}$ and $d_\mathrm{sr}$. The tabulated $A_\mathrm{gr}$ and $D_z$ of the
[ISO 9613-2 method](https://docs.jmrp.io/phonometry/environment/propagation/outdoor-propagation/) are octave-band,
energy-based engineering fits; `ground_effect` and `barrier_insertion_loss` are
their narrowband wave-acoustic counterparts. Over hard ground both agree on the
+6 dB enhancement and the 5 dB grazing barrier floor, but only the wave
models resolve the interference dips that move with geometry, frequency and
ground impedance, which is why they are the natural infrastructure for the
meteorological schemes of Nord2000 and CNOSSOS.

## What this guide covers

- **Covered.** The Weyl-Van der Pol spherical-wave ground reflection coefficient
  (`ground_effect`, Attenborough Eq. 2.40a/c, Salomons Eq. 3.2/D.58, the
  Faddeeva-function boundary-loss factor), with its hard-ground +6 dB,
  grazing-incidence and reciprocity limits pinned as tests. Wave-theoretic
  barrier diffraction (`barrier_insertion_loss`): the Kurze-Anderson closed form
  (`kurze_anderson_attenuation`, Bies Eq. 5.138), the exact rigid half-plane
  (MacDonald / Hadden & Pierce, Attenborough Eqs. 9.19-9.20), thick barriers
  through the double-edge Fresnel number (Bies Eq. 5.157), and the coherent
  four-path barrier-on-ground model weighted by the `ground_effect` reflection
  coefficient.

- **Not covered.** Both models assume a homogeneous, non-refracting, non-turbulent atmosphere; a
  vertical sound-speed gradient is the subject of the separate [atmospheric
  refraction](https://docs.jmrp.io/phonometry/environment/propagation/atmospheric-refraction/) guide
  instead. The coherent barrier-on-ground model weights all four diffracted
  paths with a single reflection coefficient $Q$ computed over the overall
  source-receiver geometry rather than a separate coefficient per image path, so
  it is coherent and reciprocal but not a full boundary-element solution.

## See also

- [Outdoor Sound Propagation](https://docs.jmrp.io/phonometry/environment/propagation/outdoor-propagation/): the octave-band ISO 9613-2 fits these models sit underneath, and the rule an obstacle has to satisfy to be a barrier at all.
- [Atmospheric refraction: rays and the GFPE](https://docs.jmrp.io/phonometry/environment/propagation/atmospheric-refraction/): the vertical sound-speed gradient both models here assume away.
- [Porous absorbers](https://docs.jmrp.io/phonometry/materials/absorbers/porous-absorbers/): the Delany-Bazley and Miki models behind `flow_resistivity_pa_s_m2`, and their fit range.
- Theory: [Outdoor propagation](https://docs.jmrp.io/phonometry/reference/theory/environment-transport/#outdoor-propagation-iso-9613-12): the ground and barrier terms of ISO 9613-2 in the context of the whole attenuation sum.
- API reference: [`environment.propagation.ground_barriers`](https://docs.jmrp.io/phonometry/reference/api/environment/ground-barriers/).
- [Published catalogues](https://docs.jmrp.io/phonometry/reference/catalogues/ground-surfaces/): the
  flow resistivity and the model parameters the books print for grass, snow,
  asphalt and the rest of the ground surfaces.

## References

- **Attenborough, K., & Van Renterghem, T. (2021).** *Predicting outdoor sound* (2nd ed.). CRC Press. https://doi.org/10.1201/9780429470806
  Chapter 2 (spherical-wave reflection over an impedance ground, the Weyl-Van der Pol equation and the boundary-loss factor) and Chapter 9 (outdoor noise barriers, the MacDonald and Hadden & Pierce diffraction solutions). ISBN 978-1-4987-4007-4.
- **Bies, D. A., Hansen, C. H., & Howard, C. Q. (2017).** *Engineering noise control* (5th ed.). CRC Press. https://doi.org/10.1201/9781351228152
  Sections 5.2.3 (spherical-wave ground reflection) and 5.3.5-5.3.7 (Fresnel number, Kurze-Anderson, thin- and thick-barrier diffraction). ISBN 978-1-4987-2405-0.
- **European Committee for Standardization. (1997).** *Road traffic noise reducing devices — Test method for determining the acoustic performance — Part 3: Normalized traffic noise spectrum* (EN 1793-3:1997).
  Table 1, the eighteen relative A-weighted one-third octave band levels both single-number ratings are weighted by. Read from the BS EN 1793-3:1998 edition.
- **European Committee for Standardization. (2012).** *Railway applications — Track — Noise barriers and related devices acting on airborne sound propagation — Test method for determining the acoustic performance — Part 3-1: Normalized railway noise spectrum and single number ratings for diffuse field applications* (EN 16272-3-1:2012).
  Table 1, the normalized railway noise spectrum, and the single-number ratings of Clauses 5 and 6 weighted by it, for a barrier beside a track. Read from the BS EN 16272-3-1:2012 edition.
- **European Committee for Standardization. (2012).** *Road traffic noise reducing devices — Test method for determining the acoustic performance — Part 1: Intrinsic characteristics of sound absorption under diffuse sound field conditions* (EN 1793-1:2012).
  Clause 5, the single-number rating DLalpha and its 0.99 ratio limit; Clause 6.1, reporting to the nearest integer; Annex A, the A1 to A5 categories. Read from the BS EN 1793-1:2012 edition.
- **European Committee for Standardization. (2012).** *Road traffic noise reducing devices — Test method for determining the acoustic performance — Part 2: Intrinsic characteristics of airborne sound insulation under diffuse sound field conditions* (EN 1793-2:2012).
  Clause 5.2, the single-number rating DLR; Clause 7.1, reporting to the nearest integer; Annex A, the B1 to B4 categories. Read from the BS EN 1793-2:2012 edition.
- **Hadden, W. J., & Pierce, A. D. (1981).** Sound diffraction around screens and wedges for arbitrary point source locations. *The Journal of the Acoustical Society of America*, *69*(5), 1266-1276. https://doi.org/10.1121/1.385809
  The exact wedge-diffraction solution whose flat-wedge (thin-screen) limit the barrier insertion loss uses.
- **Kurze, U. J., & Anderson, G. S. (1971).** Sound attenuation by barriers. *Applied Acoustics*, *4*(1), 35-53. https://doi.org/10.1016/0003-682X(71)90024-7
  The closed-form fit to Maekawa's chart in the Fresnel number.
- **Salomons, E. M. (2001).** *Computational atmospheric acoustics*. Kluwer Academic Publishers. https://doi.org/10.1007/978-94-010-0660-6
  Chapter 3 and Appendix D: the two-ray field, the plane- and spherical-wave reflection coefficients, and the numerical distance (Eqs. D.57-D.60). ISBN 978-1-4020-0390-5.