# Soundscape Analysis (ISO/TS 12913)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/environment/assessment/soundscape/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/environment/assessment/soundscape/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-24
Updated: 2026-11-16T21:36:13Z
Standards: ISO/TS 12913-3:2019; ISO/TS 12913-2:2018
Verified: 14 conformance checks (ISO/TS 12913-3:2019; ISO/TS 12913-2:2018) https://docs.jmrp.io/phonometry/reference/conformance/#soundscape-analysis-iso-ts-12913-3-2019-the-2025-edition-revises-annex-a
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Soundscape by ISO/TS 12913-2 and -3: questionnaire scales, pleasantness and eventfulness, correlations, binaural metrics and the reporting record.

---

A sound level tells how much sound arrives at a place. It does not tell whether
the people there find it pleasant, busy, calming or annoying, and two squares
at the same $L_\mathrm{Aeq}$ can be heard as opposite places. A **soundscape**
is the acoustic environment as a person perceives it, in context (ISO 12913-1),
and its study "relies primarily upon human perception and only then turns to
physical measurement" (ISO/TS 12913-2).

That makes this the first page of the library whose input is not a signal but
a **questionnaire**: the boxes people ticked on a soundwalk. ISO/TS 12913-2
prints the questionnaires and says what a study has to report; ISO/TS 12913-3
turns the ticks into numbers, places each site on a two-dimensional model of
how pleasant and how eventful it sounds, correlates the answers with the
acoustic measurements, and says how a binaural recording made at the same
place is analysed.

This page implements the **2019 edition of ISO/TS 12913-3**. ISO has published
a 2025 edition that revises Annex A, where the pleasantness and eventfulness
formulas are; it has not been read for this implementation, so a study that
cites the 2025 edition should check those formulas against it.

![Two panels. Left: the two-dimensional model of ISO/TS 12913-3 Figure A.1, pleasantness on the horizontal axis and eventfulness on the vertical one, both from minus 1 to plus 1, with the four main attributes on solid arrows and chaotic, vibrant, calm and monotonous on dashed diagonals; eleven London sites are plotted, most of them in the pleasant half, Regent's Park Japanese Garden furthest towards pleasant and slightly uneventful, Camden Town and Euston Tap on the annoying side and eventful. Right: the rank of each site's pleasantness against the rank of its LAeq, falling from upper left to lower right, titled r spearman = minus 0.638, p = 0.035, Formula (A.4), n = 11](https://docs.jmrp.io/phonometry/media/soundscape_pleasantness_eventfulness.svg)

*Eleven London sites of the International Soundscape Database on the model of
Figure A.1 (left), and the rank correlation of their pleasantness with their
level (right), both drawn by the results' own `.plot()`, with the two rank
axes named for what was ranked.*

The map below is the whole study on one sheet. The collection is
ISO/TS 12913-2: a soundwalk takes groups of up to five participants, led by a
moderator and walking in silence, to assessment sites fixed beforehand, until
each site has at least twenty independent observations (C.2.3). At each site
they listen for a set time, 3 min for example, and then answer: the four-part
questionnaire of Method A (C.3.1), or the sheet of Method B (C.3.2), with its
continuous scales, its list of up to eight sources from the most noticeable
down and its free comments. The binaural recording of Annex D is made where
they stand: the artificial head on a tripod, the entrance of its ear canal
1.6 m ± 0.1 m above the ground, 1 m or more from reflecting structures unless
the usual listener stands closer, facing where the participants look and not
moved while it measures (D.2, C.3.2.2.2); outdoors it wears a wind shield
(D.5). The analysis is ISO/TS 12913-3, one annex for each record, and it is
what the rest of this page computes.

![A map of a soundscape study in five panels. (a) The soundwalk in plan: a dashed route between buildings with four numbered assessment sites; the area and the sites are set beforehand, a moderator leads groups of up to five who walk in silence and all fill in the questionnaire at every site, with 20 or more independent observations of each site. (b) One site in elevation: three participants and, beside them, an artificial head on a tripod facing the same way, its ear 1.6 m plus or minus 0.1 m above the ground and at least 1 m from a reflecting structure; the participants listen in silence for a set time, for example 3 min, then answer on the spot, and the head is not moved while it measures. Below, three columns, each a card of what is collected with an arrow down to a card of what ISO/TS 12913-3 makes of it. (c) Method A: four parts of five boxes, sources heard, eight attributes, overall quality and appropriateness; Annex A gives the scale values of Table A.1, the median and range per site, P and E by Formulas A.1 and A.2 and Spearman's correlation against the levels. (d) Method B: continuous scales, up to eight sources by rank and free comments; Annex B gives the value from 1 to 5 to one decimal, the mean, deviation and 95 % interval, the median rank of each source and Pearson's correlation, with the comments left to a qualitative analysis. (e) The binaural recording: two channels, 3 min or longer, 44.1 kHz or more and uncompressed, a wind shield outdoors, equalized for the sound field; Annex D gives each metric of Table D.1 at each ear, the higher of the two ears' values as the representative value and a percentile ratio such as N5/N95 for the variation over time. A line from the last card feeds the two correlations: the acoustic data the answers are set against](https://docs.jmrp.io/phonometry/media/diagram_soundscape_study.svg)

*What a soundscape study collects under ISO/TS 12913-2 (the two drawings and
the upper cards) and what ISO/TS 12913-3 makes of each record (the lower
cards, each line with the function of the library that computes it). The
specification says where the head stands and which way it faces, not when it
records.*

## 1. The questionnaire and its scale values

Method A of ISO/TS 12913-2 (clause C.3.1) is a questionnaire in four parts,
every one on five boxes: which sources are heard and how much (Figure C.2, or
the three-source Figure C.3), how the place is perceived on eight attributes
(Figure C.4), how good the sound environment is overall (Figure C.5) and how
appropriate it is to the place (Figure C.6). The library publishes all of it,
every question, item and response category as printed, with the scale values
ISO/TS 12913-3 Table A.1 assigns:

```python
from phonometry import environment

part2 = environment.METHOD_A_SCALES[2]
print(part2.figure, part2.categories[0], part2.scale_values)  # C.4 Strongly agree (5, 4, 3, 2, 1)
print(environment.method_a_scale_values([1, 2, 5], part=2))  # [5. 4. 1.]
print(environment.method_a_scale_values([1, 2, 5], part=4))  # [1. 2. 5.]
```

The orientation is the thing to get right. Parts 1 and 4 run 1 to 5 from the
left-hand box, so "not at all" is 1; parts 2 and 3 run **5 to 1**, so
"strongly agree" and "very good" are 5. `method_a_scale_values` converts the
position of a ticked box, counted from the left, into the value of its part;
everything after it takes scale values, never box positions.

The tables keep the text as printed, including two slips of the page: the
questions of Figures C.2 to C.4 read "to what extend" and their instructions
"reponse alternative". A study that prints its questionnaire from them should
correct both; the [errata register](https://docs.jmrp.io/phonometry/reference/errata/) has the
entry.

## 2. Median and range per site

Every Method A scale is ordinal, so ISO/TS 12913-3 A.2 reports the **median**
of each item per site as its central tendency and the **range** as its
dispersion. A blank answer is left out of both:

```python
answers = {"pleasant": [5, 4, 4, 2, 5], "annoying": [1, 2, 1, 4, 1]}
summary = environment.method_a_summary(
    answers, part=2, sites=["park", "park", "park", "road", "road"]
)
print(summary.sites)              # ('park', 'road')
print(summary.medians.tolist())   # [[4.0, 1.0], [3.5, 2.5]]
print(summary.ranges.tolist())    # [[1.0, 1.0], [3.0, 3.0]]
```

A 2-D array `(responses, items)` is read in the order of the part's figure,
and `summary.plot()` draws each item's median with its range as a bar, site
beside site.

## 3. Pleasantness and eventfulness

The eight attributes of part 2 are not eight independent judgements. When
people describe how an environment feels, their answers fall on two
dimensions: how **pleasant** it is, and how **eventful**, how busy with human
and other activity. Rotating those two axes by 45 degrees gives the other two
pairs of attributes: vibrant is pleasant and eventful, chaotic eventful and
annoying, monotonous annoying and uneventful, calm uneventful and pleasant.
Formulas (A.1) and (A.2) project the eight answers onto the two main axes, with
$\cos 45^\circ$ weighting the diagonal ones:

$$
P = (p - a) + \cos 45^\circ\,(ca - ch) + \cos 45^\circ\,(v - m)
$$

$$
E = (e - u) + \cos 45^\circ\,(ch - ca) + \cos 45^\circ\,(v - m)
$$

with $p$ pleasant, $a$ annoying, $ca$ calm, $ch$ chaotic, $v$ vibrant, $m$
monotonous, $e$ eventful and $u$ uneventful, each a scale value from 1 to 5.
Every term is a difference, so a respondent who gives every attribute the same
answer sits at the origin, and the extremes are
$\pm(4 + \sqrt{32}) = \pm 9.66$: 4 from the main axis and $8\cos 45^\circ$
from the two diagonals. Dividing by $4 + \sqrt{32}$ maps the coordinates to
$\pm 1$.

The eleven London sites of the International Soundscape Database were surveyed
almost entirely with the English questionnaire of Method A; ten answers, at four
of the sites, were given on the Spanish version of the database's survey and
are counted too. Here are the site medians of their answers and the median
$L_\mathrm{Aeq}$ of their recordings:

```python
sites = ["Camden Town", "Euston Tap", "Marchmont Garden", "Pancras Lock",
         "Regent's Park Fields", "Regent's Park Japan", "Russell Square",
         "St Paul's Cross", "St Paul's Row", "Tate Modern", "Torrington Square"]
# Site medians of the eight attributes, in the order of Figure C.4:
# pleasant, chaotic, vibrant, uneventful, calm, annoying, eventful, monotonous.
medians = [
    [3, 4, 4, 2, 2, 3, 4, 3], [2, 4, 3, 3, 2, 3, 3, 3], [4, 2, 3, 3, 4, 2, 3, 2],
    [4, 3, 3, 2, 4, 2, 3, 2], [5, 2, 3, 3, 4, 1, 3, 2], [5, 1, 4, 3, 5, 1, 3, 2],
    [4, 2, 4, 2, 4, 1, 3, 2], [4, 2.5, 4, 2, 4, 2, 3, 2], [4, 3, 4, 2, 3, 2, 3, 3],
    [4, 3, 4, 2, 4, 2, 4, 2], [3, 4, 4, 3, 2, 3, 3, 2],
]
laeq_db = [69.96, 69.45, 55.14, 59.02, 53.12, 59.74, 66.12, 61.83, 63.34, 63.00, 63.51]

pe = environment.pleasantness_eventfulness(medians, sites=sites)
print(round(pe.normalized_pleasantness[5], 2), round(pe.normalized_eventfulness[5], 2))  # 0.85 -0.15
print(round(pe.normalized_pleasantness[0], 2), round(pe.normalized_eventfulness[0], 2))  # -0.07 0.43
print(round(environment.PLEASANTNESS_EVENTFULNESS_RANGE, 2))  # 9.66
```

Regent's Park Japanese Garden (index 5) comes out the most pleasant and
slightly uneventful, in the calm quadrant; Camden Town (index 0) is the most
eventful and a little on the annoying side. `pe.plot()` draws the model of
Figure A.1 with every site on it, the left panel of the figure at the top.

Given the answers of each respondent rather than site medians,
`pleasantness_eventfulness` returns both: every respondent's own coordinates
(`respondent_pleasantness`, `respondent_eventfulness`) and the site's. The site
point is the formulas applied to the **site median** of each attribute, since
A.2 makes the median the central tendency of the scale;
`central_tendency="mean"` uses the mean instead. When every respondent answered
all eight attributes, that mean point is also the mean of the respondents'
coordinates, the formulas being linear; a blank answer breaks the equality,
because each attribute mean then runs over the respondents who answered that
attribute. `pe.plot(respondents=True)` adds every respondent as a faint point
in the colour of their site.

Clause A.3 introduces the formulas as processing "the results from part 3".
The attributes they read are part 2, as Table A.1, the rest of Annex A and
ISO/TS 12913-2 Figure C.4 all say; part 3 is the single overall rating of
Figure C.5. The library applies them to part 2, and the
[errata register](https://docs.jmrp.io/phonometry/reference/errata/) has the entry.

## 4. Linking the ratings to the acoustic data

A study then asks whether what people say goes with what was measured. For
ordinal data A.4 prescribes **Spearman's rank correlation**: without ties
Formula (A.3),

$$
r_\mathrm{spearman} = 1 - \frac{6\sum_{i=1}^{n} d_i^2}{n(n^2 - 1)},
$$

with $d_i$ the difference of the ranks of pair $i$, and with ties in either
variable Formula (A.4), which corrects the rank variances by the tie sums
$T = \sum_j (t_j^3 - t_j)/12$ and $U$ of the two variables and is Pearson's
coefficient of the average ranks. The site medians above have ties, so:

```python
rho = environment.spearman_rank_correlation(pe.pleasantness, laeq_db)
print(rho.formula, round(rho.coefficient, 3), round(rho.p_value, 3))  # (A.4) -0.638 0.035

r = environment.pearson_correlation(pe.pleasantness, laeq_db)
print(r.formula, round(r.coefficient, 3), round(r.p_value, 3))  # (B.1) -0.66 0.027
```

Across these eleven sites the louder places are the less pleasant ones, and
significantly so. Over all 26 locations of the database the rank correlation
is about $-0.51$ ($p < 0.01$). A.4 and B.3 ask for the probability value
without naming a test; both functions use the Student statistic
$r\sqrt{(n-2)/(1-r^2)}$ with $n - 2$ degrees of freedom, exact for Pearson's
coefficient of bivariate normal data and the usual approximation for
Spearman's.
`alternative="greater"` or `"less"` gives the one-sided value.

Three details of the page are worth knowing. Formula (A.3) is printed as
$1 - 1\,\tfrac{6\sum d_i^2}{n(n^2-1)}$, with a stray factor 1 that the library
reads as the typesetting remnant it is. The where-list under Formula (A.4)
defines $t_j$ as "the number of in $t_j$ tied ranks" and $k(x)$ as "the numbers
of tied ranks"; the library reads them as the size of each group of tied values
and the number of those groups, the usual tie correction. And Formula (B.2),
Pearson's covariance for interval data, divides by $n$; the standard deviations
of (B.1) are then taken with $n$ as well, which is what makes $r$ the usual
coefficient. The first two, and a stray capital in the where-list of (B.2), are
in the [errata register](https://docs.jmrp.io/phonometry/reference/errata/).
`rho.plot()` draws the ranked pairs, the right panel of the figure at the top.

## 5. Method B: continuous scales and the source ranking

Method B (ISO/TS 12913-2 C.3.2) is the soundwalk data collection: at each
stop the participants mark continuous scales, list the sources they noticed
from the most noticeable down, and write down what went through their mind. A
mark may fall anywhere along a scale; its value runs from 1 at the left-hand
tick to 5 at the right-hand one and is taken to one decimal (ISO/TS 12913-3
B.2). The level of measurement is interval, so B.2 reports the **mean**, the
**standard deviation** and the **95 % confidence interval** per site:

```python
print(environment.method_b_scale_values([0.0, 0.37, 1.0]))  # [1.  2.5 5. ]

ratings = {"How loud is it here?": [3.9, 4.2, 3.1, 4.4, 3.6, 4.0]}
b = environment.method_b_summary(ratings)
print(round(b.means[0, 0], 2), round(b.standard_deviations[0, 0], 2))       # 3.87 0.46
print(round(b.confidence_lower[0, 0], 2), round(b.confidence_upper[0, 0], 2))  # 3.38 4.35

ranking = environment.method_b_source_ranking(
    [["traffic", "voices", "birds"], ["traffic", "birds"], ["voices", "traffic"], ["traffic"]]
)
print(ranking.sources, ranking.median_ranks[0].tolist())  # ('traffic', 'voices', 'birds') [1.0, 1.5, 2.5]
```

The interval is the Student one about the mean with the sample standard
deviation; the median is reported beside it, as the "statistics for an
ordinal scale level" B.2 allows. The source ranking is ordinal too: the median
rank of each source and its range, over the participants who listed it.

The text of C.3.2.3 describes three scales labelled from "not at all" to
"extremely"; Figure C.7 prints four, the fourth ("How often would you like to
visit this place again?") labelled from "never" to "very often".
`METHOD_B_SCALES` holds the four as printed and `method_b_summary` takes a
table of three or four of them; the contradiction is in the
[errata register](https://docs.jmrp.io/phonometry/reference/errata/).

## 6. The binaural analysis

A soundscape study records the place with an artificial head at 1.6 m, for at
least 3 min, sampled at 44.1 kHz or more (ISO/TS 12913-2 Annex D), and
equalizes the recording to approximate a monaural measurement before it is
analysed. Every metric of ISO/TS 12913-3 Table D.1 is then determined **for
each ear**, and the higher of the two is the single representative value
"indicating the overall experience"; their mean may be reported as well (D.2).
`binaural_indicators` does that for a calibrated two-channel recording, left
ear first, with the library's own implementation of each metric. A synthetic
street, eight seconds with one vehicle passing left to right:

```python
import warnings

import numpy as np

fs = 48_000
rng = np.random.default_rng(12913)
t = np.arange(8 * fs) / fs
background = 0.02 * rng.standard_normal(t.size)
swell = np.exp(-0.5 * ((t - 4.0) / 0.9) ** 2)
vehicle = 0.08 * rng.standard_normal(t.size)
left = background + swell * vehicle
right = 0.9 * background + 10 ** (-3 / 20) * np.roll(swell, int(0.3 * fs)) * vehicle

with warnings.catch_warnings():
    # Eight seconds is short of the 3 min of ISO/TS 12913-2 D.3, which the
    # analysis would otherwise say with a SoundscapeWarning.
    warnings.simplefilter("ignore", environment.SoundscapeWarning)
    bi = environment.binaural_indicators(
        np.vstack([left, right]), fs, parameters=("sound_pressure_level", "loudness", "sharpness")
    )
laeq = bi.metrics["LAeq,T"]
print(round(laeq.left, 1), round(laeq.right, 1), round(laeq.representative, 1))  # 63.5 61.1 63.5
print(round(bi.representative("N5"), 1), round(bi.representative("N5/N95"), 2))  # 22.2 2.27
print(sorted(bi.not_implemented))  # ['S5', 'S95', 'Saverage']
```

Each row of the table comes from a function the library already has, and each
metric says which in its `method`:

| Table D.1 row | Metrics per ear | Computed with |
|:---|:---|:---|
| Sound pressure level (ISO 1996-1) | $L_{\mathrm{Aeq},T}$, $L_{\mathrm{Ceq},T}$, $L_{\mathrm{AF5},T}$, $L_{\mathrm{AF95},T}$ | `signals.laeq`, `signals.leq` of the C-weighted signal, `signals.ln_levels` with time weighting F |
| Loudness (ISO 532-1) | $N_5$, $N_\mathrm{average}$, $N_\mathrm{rmc}$, $N_{95}$, $N_5/N_{95}$ | `psychoacoustics.loudness_zwicker`, time-varying |
| Sharpness (DIN 45692) | $S_5$, $S_\mathrm{average}$, $S_{95}$ | not computed, see below |
| Psychoacoustic tonality (ECMA 74) | $T$ | `psychoacoustics.tonality_ecma` (ECMA-418-2:2025) |
| Roughness | $R_{10}$, $R_{50}$ | `psychoacoustics.roughness_ecma` (ECMA-418-2:2025) |
| Fluctuation strength | $F_{10}$, $F_{50}$ | `psychoacoustics.fluctuation_strength_ecma` (ECMA-418-2:2025) |

$N_\mathrm{rmc}$ is the root mean cube of the loudness over time, the cube
root of the mean of $N^3$, as the formula of the NOTE under ISO/TS 12913-2
A.3 f) prints it; the text of that NOTE calls the second step "the exponent 3"
where the formula applies $1/3$, and the
[errata register](https://docs.jmrp.io/phonometry/reference/errata/) has the entry. $N_5/N_{95}$ is
the variability ratio D.2 suggests. Table D.1 cites ECMA-74 for tonality; the
current edition of ECMA-74 refers its psychoacoustic tonality method to
ECMA-418-2 clause 6, which is what `tonality_ecma` implements. For roughness
and fluctuation strength the table cites a textbook, and ISO/TS 12913-2
Annex B noted in 2018 that no standardized method existed; the library uses the
hearing model of ECMA-418-2:2025 for both, and $R_{10}$ is the value that
model reports as its roughness (the value exceeded 10 % of the time).

The **sharpness row is left empty, on purpose**. $S_5$, $S_\mathrm{average}$
and $S_{95}$ are percentiles of a sharpness that varies in time. The library's
DIN 45692 sharpness is computed from the stationary specific loudness, and its
time-varying loudness does not publish the specific loudness over time a
time-varying sharpness needs, so `not_implemented` says why instead of a
stationary number appearing under a percentile's name.

The hearing-model metrics are expensive: on a 3 min recording tonality,
roughness and fluctuation strength take minutes each, tonality most of all.
`parameters` picks the rows to compute. A recording shorter than 3 min or
sampled below 44.1 kHz raises a `SoundscapeWarning`; the equalization, the
position and the calibration are the caller's.

![Two bar charts for the synthetic street recording, left ear in one colour and right ear in another, with a dark line across each pair at the higher of the two. Left: the sound pressure levels, LAeq,T about 63.5 and 61.1 dB, LCeq,T about 62.1 and 59.7 dB, LAF5,T about 69.4 and 66.5 dB, LAF95,T about 57.2 and 56.3 dB. Right: the loudness, N5 about 22.2 and 18.5 sone, N average about 13.3 and 11.7, N rmc about 14.7 and 12.7, N95 about 9.8 and 9.2, titled with the ratio N5/N95 of 2.27 at the left ear and 2.01 at the right](https://docs.jmrp.io/phonometry/media/soundscape_binaural_indicators.svg)

*Two rows of Table D.1 at both ears of the synthetic street, from
`bi.plot(parameter="sound_pressure_level")` and `bi.plot(parameter="loudness")`.
The left ear hears the vehicle first and louder, so it is the representative
ear for every metric.*

## 7. What the report has to say

ISO/TS 12913-2 Annex A (normative) lists the minimum a soundscape study
reports: who the participants were and how they were selected (A.2), the
acoustic environment with the results of its measurements (A.3), and how the
perception data were collected (A.4), with a copy of the questionnaire.
`SoundscapeReport` holds the three records and refuses to be built with a
required item missing, naming its clause; the seven results of A.3 f) come
straight from the binaural analysis:

```python
report = environment.SoundscapeReport(
    participants=environment.SoundscapeParticipants(
        selection="visitors approached at the entrance, one in three",
        residents_or_visitors="visitors",
        lay_or_expert="lay people",
        age_and_gender_distribution="18 to 74 years, 52 % women",
        other_relevant_information="self-reported normal hearing",
    ),
    acoustic_environment=environment.SoundscapeAcousticEnvironment(
        environment_type="real",
        sound_sources="road traffic in the background, a passing car in the foreground",
        weather_and_wind="dry, wind under 2 m/s",
        time_of_year_and_day="June, 14:00 to 16:00",
        measurement_points="kerbside, artificial head at 1.6 m facing the road",
        measurement_results=bi.reporting_results(),
        site_description="urban street, residential",
    ),
    data_collection=environment.SoundscapeDataCollection(
        methods="Method A questionnaire, parts 1 to 4",
        questions="Figures C.2 to C.6 of ISO/TS 12913-2, answers on paper",
        language="English, as printed in Annex C",
        instrument_copy="Appendix B",
        rating_scale_construction="five-category scales of Figures C.2 to C.6",
    ),
)
print(round(report.acoustic_environment.measurement_results["N5"], 1))  # 22.2
```

Each item is free text, because the annex says what is stated and not how. A
site description is required for a field study or recordings, the recording
and reproduction for a recorded or virtual environment; a record that exists
meets the minimum as far as a record can tell, and whether what it says is
true and sufficient stays with the author.

**Show the code for these figures**

```python
import matplotlib.pyplot as plt

fig, (ax_model, ax_rank) = plt.subplots(1, 2, figsize=(14.0, 6.6))
pe.plot(ax_model)    # Figure A.1 with the eleven sites
rho.plot(ax_rank)    # the ranked pairs of Formula (A.4)
ax_rank.set_xlabel(r"Rank of the site pleasantness $P$")
ax_rank.set_ylabel(r"Rank of the site $L_\mathrm{Aeq}$")
plt.tight_layout()   # room for the site legend under Figure A.1

fig, (ax_levels, ax_loudness) = plt.subplots(1, 2, figsize=(14.0, 5.8))
bi.plot(ax_levels, parameter="sound_pressure_level")
bi.plot(ax_loudness, parameter="loudness")
plt.tight_layout()
plt.show()
```

## What this guide covers

- **Covered.** **ISO/TS 12913-3:2019, the quantitative analysis:** the scale values of
  Table A.1 with the orientation of each part, the median and range per site and
  item (A.2), the pleasantness and eventfulness of Formulas (A.1) and (A.2) per
  respondent and per site, raw and normalised, with the model of Figure A.1 as
  the plot; Spearman's coefficient with Formulas (A.3) and (A.4) and Pearson's
  with (B.1) and (B.2), each with its probability value; the Method B scale
  values, mean, standard deviation, confidence interval and source ranking of
  Annex B; and the binaural analysis of Annex D, every metric of Table D.1 the
  library implements at each ear with the representative value of D.2 and the
  $N_5/N_{95}$ ratio. **ISO/TS 12913-2:2018:** the questionnaires of Annex C as
  published tables, the recording checks of Annex D (3 min, 44.1 kHz), and the
  minimum reporting requirements of Annex A as a record.

- **Not covered.** The 2025 edition of ISO/TS 12913-3, which revises Annex A, is not implemented.
  The time-varying sharpness $S_5$, $S_\mathrm{average}$ and $S_{95}$ of Table
  D.1 is not computed. The qualitative analyses (the Grounded Theory and content
  analysis of clause 6 and Annex C, the free comments of Method B, the interview
  guideline of Method C), the triangulation of Annex E, the laboratory studies of
  Annex F, the clustering and psychoacoustic mapping of D.2 and D.3, the
  unexplained variance of D.1 and the coefficient of variation of repeated
  measurements are not modelled. The equalization of the binaural recording and
  the binaural measurement protocol of ISO/TS 12913-2 D.7 are the caller's.

## See also

- [Environmental Levels (ISO 1996-1/-2)](https://docs.jmrp.io/phonometry/environment/assessment/environmental-levels/):
  the rating framework the sound pressure levels of Table D.1 are defined in.
- [Integrated and Statistical Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/):
  $L_\mathrm{Aeq}$, $L_\mathrm{Ceq}$ and the percentile levels the binaural
  analysis reads at each ear.
- [Loudness](https://docs.jmrp.io/phonometry/perception/psychoacoustics/loudness/):
  the ISO 532-1 time-varying loudness behind $N_5$, $N_{95}$ and $N_\mathrm{rmc}$.
- [Sound Quality Metrics](https://docs.jmrp.io/phonometry/perception/psychoacoustics/sound-quality/):
  the DIN 45692 sharpness and the ECMA-418-2 tonality, roughness and
  fluctuation strength of Table D.1.
- [Errata in published sources](https://docs.jmrp.io/phonometry/reference/errata/): part 3 for
  part 2, the stray factor of Formula (A.3), the where-lists of (A.4) and
  (B.2), the exponent of the $N_\mathrm{rmc}$ NOTE, three scales for four,
  and the misspellings of the questionnaire.
- API reference: [`environment.assessment.soundscape`](https://docs.jmrp.io/phonometry/reference/api/environment/soundscape/)
  and [`environment.assessment.soundscape_binaural`](https://docs.jmrp.io/phonometry/reference/api/environment/soundscape-binaural/).

## References

- **International Organization for Standardization. (2014).** *Acoustics — Soundscape — Part 1: Definition and conceptual framework* (ISO 12913-1:2014).
  The definition of soundscape and the terms the other two parts use.
- **International Organization for Standardization. (2018).** *Acoustics — Soundscape — Part 2: Data collection and reporting requirements* (ISO/TS 12913-2:2018).
  The questionnaires of Annex C transcribed as published tables, the binaural measurement requirements of Annex D the analysis checks, and the minimum reporting requirements of Annex A as a record.
- **International Organization for Standardization. (2019).** *Acoustics — Soundscape — Part 3: Data analysis* (ISO/TS 12913-3:2019).
  The analysis implemented: the scale values and ordinal statistics of Annex A (Table A.1), the pleasantness and eventfulness of Formulas (A.1) and (A.2) with the model of Figure A.1, Spearman's coefficient of Formulas (A.3) and (A.4), the Method B statistics and Pearson's coefficient of Annex B, and the binaural metrics and representative values of Annex D (Table D.1). This is the first edition. ISO has since published ISO/TS 12913-3:2025, which revises Annex A; it has not been read for this implementation.
- **Mitchell, A., Oberman, T., Aletta, F., & et al. (2024).** [*The International Soundscape Database (ISD), v1.0*](https://doi.org/10.5281/zenodo.10672568). Zenodo.
  Licensed CC BY 4.0. The eleven London sites of this page are derived from its survey data: the median of each of the eight attributes per site and the median LAeq of the site's recordings. Used as real data for the examples and as a consistency check of the formulas, not as a calibration reference.