# Impulsive Sound Exposure Statistics (ISO 13474)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/environment/assessment/sel-distribution/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/environment/assessment/sel-distribution/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-24
Updated: 2026-11-16T21:36:14Z
Standards: ISO 13474:2009
Verified: 7 conformance checks (ISO 13474:2009) https://docs.jmrp.io/phonometry/reference/conformance/#impulsive-sound-exposure-distribution-iso-13474
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: ISO 13474:2009 distribution of a distant blast's sound exposure level: long-term and rating levels, turbulence spread and exceedance levels.

---

A blast, a shot or a detonation a few kilometres away is not heard at one
level. The same charge fired twice from the same place reaches the same
receiver ten decibels apart and more, because the wind, the temperature
profile and the ground between them change from one hour to the next, and at
long range they decide more of the level than the distance does. An
environmental assessment of a firing range or a quarry therefore cannot ask
how loud one event is. It asks **how often an event is how loud**.

ISO 13474:2009 answers with a statistical distribution. The weather is
described as a set of **replica atmospheres**, each one a combination of an
atmospheric-absorption class and an excess-attenuation class with its
probability of occurrence; the single-event sound exposure level is computed
for each; and the list of levels and probabilities is turned into a density,
spread for the turbulence the replicas leave out, from which the long-term
level and the level exceeded by any percentage of the events are read.

This page is that statistical core, run on the example the standard prints in
its Annex A: a TOW anti-tank missile launcher heard at 3 020 m under 27
excess-attenuation classes.

![Two panels for the TOW launcher of ISO 13474 Annex A. Left: the step density of the 27 classes before the turbulent spread, against the single-event sound exposure level from 27 to 47 dB; a tall narrow class near 30.8 dB reaches 1.24 per decibel, a second group of narrow classes sits near 31.8 dB, and low wide steps run out to 46 dB. Right: the same distribution spread by a normal distribution of 5 dB standard deviation, a smooth bell peaking near 30.5 dB at about 0.061 per decibel with a long tail towards high levels, and a dashed vertical line at the long-term level LT2 of 37.0 dB](https://docs.jmrp.io/phonometry/media/sel_distribution_density.svg)

*The classes of Annex A before the spread (left, Figure A.1 of the standard)
and after it (right, Figure A.2), with the long-term level LT2 marked.*

## 1. One number per replica atmosphere

Each replica atmosphere gives a band sound exposure level at the receiver, the
source level less the attenuation of every mechanism along the path (Equation
(4)). What the statistics work on is one frequency-weighted level per replica,
the energy sum over the bands of Equation (5):

$$
L_{E,\mathrm{w}} = 10\lg \sum_{j} 10^{0.1\left[L_E(j) + \mathrm{w}(j)\right]}~\text{dB}
$$

The weighting is whatever the assessment uses, A or C, given as one value per
band. Here it is applied to the octave-band source levels of the launcher that
Annex A prints in its Table A.1, with the A-weighting at the octave centres:

```python
from phonometry import environment

source_db = [115.0, 119.0, 134.0, 135.0, 134.0, 136.0, 133.0, 126.0]  # 31.5 Hz to 4 kHz
a_weighting_db = [-39.4, -26.2, -16.1, -8.6, -3.2, 0.0, 1.2, 1.0]
print(round(environment.frequency_weighted_sel(source_db, a_weighting_db), 1))  # 139.5
```

An array of shape `(N_atm, N_exc, n_bands)` holding the band levels of every
replica returns the `(N_atm, N_exc)` weighted levels in one call. The
probability of a replica is the product of the probabilities of its two
classes, which the standard takes as independent (Equation (14)):
`environment.replica_probabilities(p_atm, p_exc)` returns that product as the
same `(N_atm, N_exc)` grid.

Annex A uses a single atmospheric-absorption class of probability 1, so its
replicas are its 27 excess-attenuation classes. Table A.3 gives the A-weighted
level of each at the receiver, and its probability by day and by night; the
07:00 to 19:00 period of the assessment is 80 % day and 20 % night:

```python
import numpy as np

levels = [30.5, 31.2, 31.3, 36.1, 38.3, 38.8, 39.2,
             30.8, 31.8, 31.8, 33.7, 40.2, 41.0, 41.6, 42.2, 42.4, 42.7, 43.1,
             28.4, 30.8, 32.2, 42.3, 43.6, 44.5, 45.2, 45.5, 46.1]
day = [0.0360, 0.0053, 0.0003, 0.0731, 0.0951, 0.0634, 0.0,
       0.2037, 0.1087, 0.0184, 0.0279, 0.0001, 0.0, 0.0549, 0.0482, 0.0209, 0.0039, 0.0003,
       0.0, 0.0356, 0.2042, 0.0001, 0.0, 0.0, 0.0, 0.0, 0.0]
night = [0.0, 0.0, 0.0, 0.0664, 0.0966, 0.0962, 0.0,
         0.1151, 0.0295, 0.0, 0.0268, 0.0084, 0.0, 0.0665, 0.0445, 0.0172, 0.0033, 0.0003,
         0.0069, 0.0798, 0.2310, 0.0215, 0.0260, 0.0263, 0.0194, 0.0153, 0.0030]
probabilities = 0.8 * np.asarray(day) + 0.2 * np.asarray(night)
```

## 2. The long-term level, and the rating level with K

The expectation of the energy over the replicas is the **long-term average
single-event sound exposure level** of Equation (7), and with the adjustment
$K$ for highly impulsive sound of ISO 1996-1 inside the sum it is the
**rating level** of Equation (8), the quantity the standard hands on to an
ISO 1996-1 assessment:

$$
\langle L_{E,\mathrm{w}}\rangle_\mathrm{LT} = 10\lg\left[\sum_{k}\sum_{l}
\wp_{\mathrm{atm},k}\,\wp_{\mathrm{exc},l}\,10^{0.1 L_{E,\mathrm{w},k,l}}\right]~\text{dB}
$$

```python
print(round(environment.long_term_sel(levels, probabilities), 1))  # 37.0
print(round(environment.long_term_sel(levels, probabilities, rating_adjustment=12.0), 1))  # 49.0
```

37.0 dB is the LT1 Figure A.3 prints. It sits well above the level half the
events exceed, 31.5 dB, because an energy mean is dominated by the loud
minority: the downwind classes above 40 dB hold 15 % of the events and more
than half of the energy.

## 3. Classes, boundaries and densities

To turn the list into a distribution, Equation (10) sorts the levels, and each
becomes a **class** whose boundaries lie half-way between it and its
neighbours (Equation (11)); the two outer boundaries mirror the nearest inner
one about the end level (Equations (12) and (13)). The probability of a class
spread evenly over its width is its density (Equation (15)):

$$
\rho_m = \frac{\wp_m}{g_{\mathrm{U},m} - g_{\mathrm{L},m}}
$$

```python
dist = environment.sel_distribution(levels, probabilities, sigma_db=5.0, n_subclasses=10)
print(dist.levels[:4])                         # [28.4 30.5 30.8 30.8]
print(dist.lower_bounds_db[:4].round(2))          # [27.35 29.45 30.65 30.8 ]
print([round(float(r), 4) for r in dist.class_densities_per_db[:4]])  # [0.0007, 0.024, 1.2399, 0.2222]
print(dist.replicas[2], dist.replicas[3])         # (7,) (19,)
```

That is Table A.4, and every one of its 27 rows comes out digit for digit.
Two things in it are worth seeing. The class densities are the full-precision
probabilities over the widths, not the rounded column printed beside them:
0.1860 over 0.15 dB would print 1.2400, and the table prints 1.2399. And two
pairs of classes share a level, 30.8 dB (Table A.3 rows 8 and 20) and 31.8 dB
(rows 9 and 10). Equation (11) puts their common boundary at that level and
each keeps its half on its own side, so the table keeps both, and
`replicas` says which input each came from. The standard names the case of
three consecutive equal levels, whose middle class has no width, and for it
tells you to combine classes of the same level; a pair at either end of the
list has the same problem through Equation (12) or (13), which the standard
does not mention and the library treats the same way. `sel_distribution`
combines exactly those runs and leaves every other pair as Annex A does.

## 4. Spreading for turbulence

The replicas describe the average state of the atmosphere, not its random
perturbations, and field measurements show a spread of the level about each
replica that the standard models as a normal distribution with a standard
deviation of typically 5 dB. The convolution is carried out in two steps.
Each class is split into $N_\mathrm{sub}$ equal subclasses centred at
$\mu_{m,j}$ (Equations (17) and (18)), ten in Annex A; each subclass is then
replaced by a Gaussian carrying its probability (Equation (21)).

The Gaussian is not centred on the subclass. A level is a logarithm of an
energy, and a symmetric spread of the level raises the mean energy, so each
Gaussian is centred $\Delta\mu$ below the subclass to keep its energetic mean
where the subclass was (Equation (22)):

$$
\Delta\mu = 10\lg\left[\frac{1}{\sigma\sqrt{2\pi}}\int_{-\infty}^{\infty}
10^{0.1x}\,\mathrm{e}^{-x^2/(2\sigma^2)}\,\mathrm{d}x\right]
= \frac{\sigma^2\ln 10}{20}~\text{dB}
$$

```python
print(round(environment.turbulence_level_shift(5.0), 3))   # 2.878
print(round(dist.level_shift, 3))                       # 2.878
```

Annex A says the shift of its example was 1.04 dB. That is Equation (22) at a
standard deviation of 3 dB, not at the 5 dB of the same paragraph, and the
rest of the annex was computed with 2.878 dB: with 1.04 dB every level of the
distribution would move up by 1.84 dB and the long-term level of the next
section would read 38.8 dB, not 37.0 dB. The
[errata register](https://docs.jmrp.io/phonometry/reference/errata/) has the entry. The library
evaluates the integral in closed form, so the shift is not a parameter.

## 5. Exceedance levels, and the long-term level again

The spread density $\rho^{*}(x)$ is continuous, and everything is read from
it. The probability that an event exceeds $x$ is its upper tail (Equation
(24)), and the $n$-percent exceedance level is the level exceeded with
probability $n/100$ (Equation (25)):

$$
\mathrm{P_r}(L_{E,\mathrm{w}} > x) = \int_x^{\infty} \rho^{*}(x')\,\mathrm{d}x'
$$

```python
print(dist.exceedance_level([95.0, 50.0, 10.0, 5.0, 1.0]).round(1))  # [21.6 31.5 40.5 43.  47.5]
print(round(dist.exceedance(37.0), 3))                                 # 0.214
print(round(dist.long_term_level, 2), round(dist.distribution_long_term_level, 2))  # 37.01 36.96
```

The long-term level taken a second time, over the continuous density
(Equation (A.4), LT2), differs from LT1 only by where each class's energy sits
inside its width, and both print 37.0 dB, which is the agreement the annex
offers as its check. The probability that one event exceeds the long-term
level is 21 %: one event in five is louder than the level that stands for all
of them.

![The probability that the single-event sound exposure level of the TOW launcher exceeds x, falling from 1 below 15 dB to 0 above 50 dB, with five marked points: L95 at 21.6 dB, L50 at 31.5 dB, L10 at 40.5 dB, L5 at 43.0 dB and L1 at 47.5 dB, and a dashed vertical line at the long-term level LT2 of 37.0 dB](https://docs.jmrp.io/phonometry/media/sel_distribution_exceedance.svg)

*The exceedance curve of the Annex A example with the five percentiles Figure
A.3 lists, as Equation (25) gives them, from `dist.plot(view="exceedance")`.*

Figure A.3 prints those five levels as 21.7; 31.5; 40.6; 43.2 and 48.0 dB.
$L_{50}$ agrees; the other four are 0.1 dB to 0.5 dB higher in print, the more
so the rarer the level, and the annex does not say how it computed them. They
are consistent with a curve accumulated from 15 dB, where the drawn curve
begins (the axis starts at 10 dB), rather than from minus infinity, when that
curve is fed the 07:00 to 19:00 column of Table A.3 as printed: all five then
come out to the printed digit. Fed the full-precision probabilities that
reproduce Table A.4, as `dist` above is, the same reading gives 48.05 dB for
$L_1$, which would print 48.1 dB, so it stays a hypothesis. The
[errata register](https://docs.jmrp.io/phonometry/reference/errata/) has the entry, and the
library evaluates Equation (24) as written.

**Show the code for these figures**

```python
import matplotlib.pyplot as plt

fig, (ax_classes, ax_density) = plt.subplots(1, 2, figsize=(13.5, 5.4))
dist.plot(ax_classes, view="classes")   # Figure A.1: the step density
dist.plot(ax_density)                   # Figure A.2: the spread density
dist.plot(view="exceedance")            # Figure A.3: the exceedance curve
plt.show()
```

## What this guide covers

- **Covered.** **ISO 13474:2009, the statistical core:** the frequency-weighted
  single-event level of Equation (5) from band levels, for any weighting; the
  probability of each replica atmosphere as the product of its two class
  probabilities (Equation (14)); the long-term average single-event level of
  Equation (7) and the rating level with $K$ of Equation (8); the ordered
  classes, their boundaries and densities of Equations (10) to (16), with the
  combination of equal levels where a class would have no width; the subclasses
  and the Gaussian spread of Equations (17) to (23), with the shift of Equation
  (22) in closed form; the exceedance probability and the $n$-percent exceedance
  level of Equations (24) and (25); and the long-term level over the continuous
  density of Equation (A.4). Table A.4 of Annex A is reproduced digit for digit
  from Table A.3, and LT1, LT2 and $L_{50}$ match Figure A.3.

- **Not covered.** The levels of the replica atmospheres are an input. The propagation that
  produces them is not implemented here: the attenuation terms of clause 6
  (divergence, atmospheric absorption, screening, terrain and the excess
  attenuation from a parabolic-equation model), the classification of the
  atmosphere of clause 7, the probability of each class from meteorological
  data of clause 8, the ground impedances of Table 1, and the source
  descriptors of clause 9. The equivalent level over an assessment period of
  Equation (9) is not given a function of its own, and the uncertainty budget of
  Annex B is not modelled. The atmospheric refraction guide below computes the
  excess attenuation of one sound speed profile, which is where a replica level
  would start.

## See also

- [Impulsive-sound prominence (NT ACOU 112)](https://docs.jmrp.io/phonometry/environment/assessment/impulsive-sound/):
  the other assessment of impulsive sound, which rates how prominent an
  impulse is at a receiver rather than how its level is distributed.
- [Environmental Levels (ISO 1996-1/-2)](https://docs.jmrp.io/phonometry/environment/assessment/environmental-levels/):
  the rating framework the long-term rating level is offered to, and the
  adjustment for highly impulsive sound it takes $K$ from.
- [Atmospheric refraction: rays and the GFPE](https://docs.jmrp.io/phonometry/environment/propagation/atmospheric-refraction/):
  sound speed profiles, rays and the GFPE, the excess attenuation of one
  replica atmosphere.
- [Integrated and Statistical Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/):
  the sound exposure level of a measured event and the percentile levels of a
  record, which this page predicts rather than measures.
- [Errata in published sources](https://docs.jmrp.io/phonometry/reference/errata/): the shift
  Annex A prints as 1.04 dB and the five exceedance levels of Figure A.3.
- API reference: [`environment.assessment.exposure_distribution`](https://docs.jmrp.io/phonometry/reference/api/environment/exposure-distribution/).

## References

- **International Organization for Standardization. (2009).** *Acoustics — Framework for calculating a distribution of sound exposure levels for impulsive sound events for the purposes of environmental noise assessment* (ISO 13474:2009).
  The implemented statistical core: the frequency-weighted level of Equation (5), the long-term average and rating level of Equations (7) and (8), the ordered classes of Equations (10) to (16), the subclasses and Gaussian spread of Equations (17) to (23), the exceedance of Equations (24) and (25), and the long-term level of Equation (A.4). Read from BS ISO 13474:2009, the UK implementation of the standard, whose pages carry the ISO 13474:2009(E) text; its Annex A is the worked example this page runs.
- **International Organization for Standardization. (2016).** [*Acoustics — Description, measurement and assessment of environmental noise — Part 1: Basic quantities and assessment procedures*](https://www.iso.org/standard/59765.html) (ISO 1996-1:2016).
  Where the rating level adjustment K for highly impulsive sound comes from, and the assessment the long-term rating level of ISO 13474 is offered to.