A silencer earns its keep in a duct: between an engine and its tailpipe,
between a fan and the room it serves. Two working principles divide the
field. A **reactive** silencer attenuates by *reflecting* sound with
impedance discontinuities (chambers, side branches) and dominates at low
frequency, where a tone from a firing engine or a fan blade passage can be
targeted exactly; a **dissipative** silencer *absorbs* sound in a porous
lining and dominates broadband, at mid and high frequency. This guide
covers the reactive family phonometry implements with the engineering
theory of Bies, Hansen & Howard and Munjal's transfer-matrix formulation:
the four-pole method, the closed-form expansion chamber, the Helmholtz,
quarter-wave and extended-tube resonators, the independent FDTD
cross-check, and the design trade-offs against dissipative linings. The
rest of the installation, HVAC duct attenuation, flow noise and machine
enclosures, lives in
[Industrial noise control](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/).

## 1. Reactive silencers (four-pole method)

Reflection is computed one element at a time. Each acoustic element is a
2x2 **transfer matrix** relating the pressure $p$ and volume velocity $Su$ at
its two ends (Bies Eq. (8.133)), and a compound silencer is the ordered matrix
product of its elements (Bies §8.9). A straight duct of length $L$ and area $S$
is (Bies Eq. (8.143), no flow)

$$
\begin{bmatrix} \cos kL & j\,\tfrac{\rho c}{S}\sin kL \\[2pt]
j\,\tfrac{S}{\rho c}\sin kL & \cos kL \end{bmatrix},
\qquad k = \omega/c,
$$

and a side branch of impedance $Z_\mathrm{b}$ is the shunt
$\left[\begin{smallmatrix} 1 & 0 \\ 1/Z_\mathrm{b} & 1 \end{smallmatrix}\right]$
(Bies Eq. (8.144)). The **transmission loss** follows from the compound matrix $T$ with the port
impedances $Z_1 = \rho c/S_\text{in}$ and $Z_n = \rho c/S_\text{out}$
(Munjal Eq. (3.27); Bies Eq. (8.141) prints the `T11`/`T22` impedance
weights of this formula inverted and fails the sudden-expansion limit, see the
[errata registry](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md))

$$
\mathrm{TL} = 10\log_{10}\!\left[\frac{Z_n}{Z_1}\,\tfrac{1}{4}\left|\,T_{11}
+ \tfrac{T_{12}}{Z_n} + Z_1\,T_{21} + \tfrac{Z_1}{Z_n}\,T_{22}\right|^2\right],
$$

which for equal inlet/outlet areas $S$ reduces to (Bies Eq. (8.148))

$$
\mathrm{TL} = 20\log_{10}\!\left(\tfrac{1}{2}\left|\,T_{11}
+ \tfrac{T_{12}}{Z_\mathrm{c}} + Z_\mathrm{c}\,T_{21} + T_{22}\right|\right),
\qquad Z_\mathrm{c} = \frac{\rho c}{S},
$$

and the **insertion loss** for a source impedance $Z_\mathrm{s}$ and radiation impedance
$Z_\mathrm{r}$ is the extra attenuation over a direct connection.

### Expansion chamber

The simplest silencer, a chamber of area $S_\text{exp}$ and length $L$ between
pipes of area $S_\text{duct}$, has the closed-form transmission loss (Bies
Eq. (8.111)) with area ratio $m = S_\text{exp}/S_\text{duct}$

$$
\mathrm{TL} = 10\log_{10}\!\left[1 + \tfrac{1}{4}\left(m - \tfrac{1}{m}\right)^2
\sin^2 kL\right],
$$

peaking at $10\log_{10}[1 + \tfrac14(m-1/m)^2]$ when $kL = \pi/2, 3\pi/2, \dots$
and dropping to $0$ at $kL = n\pi$ where the chamber is a half-wavelength long
and transparent. The four-pole product reproduces this exactly.

```python
import numpy as np
from phonometry import noise_control

freqs = np.linspace(20.0, 2000.0, 2000)
res = noise_control.expansion_chamber(freqs, length=0.3, chamber_area=0.04, pipe_area=0.01)
print(round(res.transmission_loss.max(), 2))   # 6.55 dB peak (m = 4)
# The troughs at f = n c / 2L are exactly 0 dB (no dissipation).
print(round(float(res.transmission_loss[np.argmin(res.transmission_loss)]), 6))
```

The one-liner `res.plot()` draws the transmission loss of the chamber (and its
insertion loss when the source and radiation impedances are given). The figure
below sweeps the area ratio instead: a larger mismatch $m$ lifts every peak,
but the troughs stay at 0 dB and the peaks stay at the same frequencies, set
only by the chamber length.

![Expansion-chamber transmission loss against frequency for area ratios m = 2, 4, 8 and 16, showing periodic peaks rising with m at odd multiples of the quarter-wave frequency and troughs returning to 0 dB at every half-wavelength of the chamber length](https://docs.jmrp.io/phonometry/media/silencer_expansion_chamber.svg)

*Two design levers, and only one of them is cheap. The peak,
$10\log_{10}[1 + \tfrac14(m - 1/m)^2]$, grows only as the logarithm of the area
ratio: $m = 2$ buys 1.9 dB and $m = 16$ buys 18.1 dB, so quadrupling the
chamber cross-section is worth about 6 dB, while the trough frequencies
$n\,c/2L$ never move at all, because they depend on the length alone. A chamber
is lengthened to move the notch and widened to deepen the peak.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import noise_control

freqs = np.linspace(20.0, 2000.0, 2000)

# One line for one chamber: TL vs frequency, plus the insertion loss when the
# two acoustic impedances are given (Pa.s/m3 -- see the next subsection for
# where they come from). With both set to rho c / S = 4.14e4 for this 0.01 m2
# pipe the two curves coincide, which is what "anechoic ports" means.
noise_control.expansion_chamber(freqs, 0.3, 0.04, 0.01,
                                source_impedance=4.14e4, radiation_impedance=4.14e4).plot()
plt.show()

# By hand: the family of area ratios of the concept figure.
fig, ax = plt.subplots()
for m in (2.0, 4.0, 8.0, 16.0):
    res = noise_control.expansion_chamber(freqs, 0.3, m * 0.01, 0.01)
    ax.plot(freqs, res.transmission_loss, label=f"m = {int(m)}")
ax.set_xlabel("Frequency [Hz]"); ax.set_ylabel("Transmission loss [dB]")
ax.legend()
plt.show()
```

The numbers passed to `expansion_chamber` describe a real device, and
`.plot_geometry()` draws it: the same 0.3 m chamber with its 4:1 area ratio,
to scale and fully dimensioned.

![To-scale cross-section of the expansion-chamber silencer of the transmission-loss example: a 300 mm long chamber of 225.7 mm equivalent diameter inserted between inlet and outlet pipes of 112.8 mm equivalent diameter, with the chamber length and both diameters dimensioned](https://docs.jmrp.io/phonometry/media/expansion_chamber_geometry.svg)

*The chamber behind the curves above, to scale: the areas enter the four-pole
method only through the ratio $m$, and the drawing uses the equivalent
circular diameters $d = 2\sqrt{S/\pi}$ of the 0.04 and 0.01 m² cross-sections.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import noise_control

freqs = np.linspace(20.0, 2000.0, 2000)
res = noise_control.expansion_chamber(freqs, length=0.3, chamber_area=0.04, pipe_area=0.01)

# One line: the dimensioned cross-section of the chamber just computed.
res.plot_geometry()
plt.show()

# The same drawing without a result, from the free function:
noise_control.plot_silencer_geometry(
    "expansion chamber", {"length": 0.3, "chamber_area": 0.04, "pipe_area": 0.01}
)
plt.show()
```

### Transmission loss, insertion loss, and which one a datasheet quotes

Three quantities are in circulation and they are not interchangeable.
**Transmission loss** compares the incident power entering the element with the
power leaving it into a reflection-free termination, so it is a property of the
element alone, which is exactly why it can be computed from geometry, and why
the formula above sets $Z_1 = \rho c/S_\text{in}$ and $Z_n = \rho c/S_\text{out}$
without asking what the silencer is connected to. **Insertion loss** compares
the level at a fixed point with and without the element in place, so it depends
on the source and on what the duct radiates into, and the same chamber shows a
different insertion loss in two installations. **Noise reduction** is the plain
level difference across the element, which is what a two-microphone measurement
in a live duct returns.

A reactive element is where they diverge most, because it works by sending
energy back towards a source that may re-reflect it. Both impedances are
acoustic, in Pa·s/m³ (pressure per volume velocity), and they have a scale:
$\rho c/S$ for the 0.01 m² inlet pipe is $4.14 \times 10^{4}$, so a source far
above that approximates a constant-volume-velocity machine such as a
reciprocating engine and one far below it a constant-pressure source. The
termination is not a free choice at all; for a duct discharging into a room it
is the radiation impedance of the open end,
$Z_\mathrm{r} = (\rho c/S)(R_1 + jX_1)$, whose normalised $R_1$ and $X_1$ the
[radiating piston](https://docs.jmrp.io/phonometry/devices/electroacoustics/loudspeakers/#2-radiating-piston-radiation-impedance-and-directivity)
of the electroacoustics domain returns as `radiating_piston(...).resistance` and
`.reactance` (its `radiation_resistance` and `radiation_reactance` are the
*mechanical* impedance $\rho c S(R_1 + jX_1)$ in N·s/m, a factor $S^2$ away,
and an easy thing to feed in by mistake). The source impedance of a fan or an
engine, by contrast, is rarely known and strongly frequency dependent, which is
precisely why insertion loss is a *measured* quantity in practice.

![Attenuation against frequency from 20 to 880 Hz for one 0.3 m expansion chamber of area ratio 4. A thick curve gives the transmission loss, a smooth hump between 0 and 6.5 dB with a zero at 572 Hz. Two thinner curves give the insertion loss of the same chamber discharging through the radiation impedance of its open end, one for a source matched to the pipe and one for a source twenty times stiffer: both dip far below zero near 180 Hz, to minus 9.3 and minus 22.6 dB, dip again near 645 Hz to minus 2.9 and minus 8.5 dB, and rejoin the transmission loss at the top of the band](https://docs.jmrp.io/phonometry/media/silencer_insertion_loss.svg)

*The same chamber, three answers. Transmission loss never goes below zero,
because it is defined against a termination that reflects nothing. Insertion
loss can: near 180 Hz this chamber and the open end it discharges through
resonate together, and the installation is **louder** with the silencer in it
than without: 9.3 dB louder for a source matched to the pipe and 22.6 dB for a
stiff one, where the transmission loss reads a comfortable +5 dB. This is why a
catalogue publishes a dynamic insertion loss measured with the design airflow in
the design direction, and why a computed TL is a sizing tool rather than a
specification.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import special          # expansion_chamber: imported in section 1

freqs = np.linspace(20.0, 880.0, 1600)     # below the 890.8 Hz cut-on
rho, c, pipe_area = 1.206, 343.0, 0.01
z0 = rho * c / pipe_area                   # 41.4 kPa.s/m3

# The open end, as the baffled piston: R1(2ka) and X1(2ka). The same two
# numbers come out of radiating_piston(a, freqs).resistance / .reactance.
a = np.sqrt(pipe_area / np.pi)
x = 2.0 * (2.0 * np.pi * freqs / c) * a
z_r = z0 * ((1.0 - 2.0 * special.j1(x) / x)
            + 1j * (2.0 * special.struve(1, x) / x))

# One line: the result draws the insertion loss beside the transmission loss
# whenever both impedances are given.
noise_control.expansion_chamber(freqs, 0.3, 0.04, pipe_area,
                                source_impedance=z0, radiation_impedance=z_r).plot()
plt.show()

# By hand: the two source impedances of the figure against the same outlet.
fig, ax = plt.subplots()
ax.plot(freqs, noise_control.expansion_chamber(freqs, 0.3, 0.04, pipe_area).transmission_loss,
        label="Transmission loss")
for factor, label in ((20.0, "stiff source"), (1.0, "matched source")):
    res = noise_control.expansion_chamber(freqs, 0.3, 0.04, pipe_area,
                                          source_impedance=factor * z0, radiation_impedance=z_r)
    ax.plot(freqs, res.insertion_loss, label=f"Insertion loss, {label}")
ax.set_xlabel("Frequency [Hz]"); ax.set_ylabel("Attenuation [dB]")
ax.legend()
plt.show()
```

The rule that follows is short: **do not compare a computed transmission loss
with a published insertion loss.** Write requirements against insertion loss
with the termination stated, get the number from the supplier or from a test
(section 3), and treat the transmission loss this page computes as the tool that
tells you which geometry to ask for.

The clip below runs an $m = 4$ chamber of the same 0.30 m length in a 2D FDTD
duct at its two characteristic frequencies. At $kL = \pi$ the chamber is a
half-wave resonator and the tone crosses as if it were not there; at
$kL = \pi/2$ the two area jumps reflect in phase and send the wave back up the
inlet, the 6.5 dB peak of the four-pole curve above.

**Video:** [The expansion-chamber silencer in a 2D FDTD simulation](https://docs.jmrp.io/phonometry/media/anim_fdtd_expansion_chamber.webm): A 2D FDTD duct with a 0.30 m expansion chamber of area ratio 4, drawn as hardware between a loudspeaker and an anechoic termination, at two frequencies side by side. At 572 Hz the pressure envelope stays flat and the tone crosses the chamber unchanged with the annotated transmission loss of 0.0 dB; at 286 Hz a standing wave fills the inlet pipe and the outlet is left with less than half the amplitude, matching the annotated 6.5 dB peak.

### Side-branch and extended-tube resonators

A **Helmholtz resonator** (neck area $S_\mathrm{n}$, effective length $l_\mathrm{e}$, cavity
volume $V$) and a closed **quarter-wave tube** (length $l_\mathrm{e}$) each short the
duct at their tuning frequency, giving a sharp transmission-loss spike there:
$f_0 = \tfrac{c}{2\pi}\sqrt{S_\mathrm{n}/(l_\mathrm{e} V)}$ (Bies Eq. (8.46)) and $f = c/4l_\mathrm{e}$
(Eq. (8.44)). An **extended-tube chamber** buries quarter-wave side branches in
an expansion chamber to fill the plain chamber's troughs.

Both lengths are **effective** lengths, and both functions take them that way
(`neck_length` and `length` are documented as $l_\mathrm{e}$, end corrections included).
The air in a neck does not stop moving at the mouth: it drags a slug of air
along on each side, so the mass that resonates against the cavity belongs to a
tube longer than the one that was drilled. Add about $0.85a$ per flanged end
and about $0.61a$ per free end, for a neck of radius $a$, at both ends of a
Helmholtz neck and at the open (duct) end only of a quarter-wave stub. The
resonator drawn below is the case in point: its neck is 11.3 mm across
($a = 5.64$ mm) and 20 mm long, so $l_\mathrm{e} \approx 20 + 2 \times 4.8 =
29.6$ mm and the tuning falls from the 122.1 Hz the drilled length returns to
100.3 Hz, a 22 % error on a notch the figure below shows to be only a few
hertz wide. The shorter and wider the neck, the larger the correction in
relative terms, which is exactly the regime a compact resonator lives in, so
the practical procedure is to compute a nominal length, build it long, and
trim it against a measurement.

```python
import numpy as np
from phonometry import noise_control

f = np.linspace(20.0, 600.0, 4000)

hr = noise_control.helmholtz_resonator(f, duct_area=0.01, neck_area=1e-4,
                                       neck_length=0.02, cavity_volume=1e-3)
print(round(float(hr.resonances[0]), 1))       # 122.1 Hz, for le = 20 mm
hr.plot()   # TL spike at the tuning frequency (needs matplotlib)

qw = noise_control.quarter_wave_resonator(f, duct_area=0.01, length=0.3, branch_area=2e-3)
print(round(float(qw.resonances[0]), 1))       # 285.8 Hz = c / 4 le

# Bies Example 8.1, the published anchor: a 1.516 m stub at c = 343.24 m/s.
print(round(float(noise_control.quarter_wave_resonator(
    f, duct_area=0.01, length=1.516, branch_area=2e-3,
    speed_of_sound=343.24).resonances[0]), 1))  # 56.6 Hz

# The same stub in hot exhaust gas: c(500 degC) = 343*sqrt(773/293) = 557 m/s
# (see the caution below), which moves the notch by a factor 1.62.
f_hot = np.linspace(20.0, 900.0, 6000)
qw_hot = noise_control.quarter_wave_resonator(f_hot, duct_area=0.01, length=0.3,
                                              branch_area=2e-3, speed_of_sound=557.0)
print(round(float(qw_hot.resonances[0]), 1))   # 464.2 Hz, not 285.8

# Each extension is a quarter-wave stub, so its own length picks the trough
# it fills: L/4 = 0.1 m shorts the duct at c/4(L/4) = c/L, the chamber's
# second trough, and L/2 = 0.2 m would take the first one at c/2L.
et = noise_control.extended_tube_chamber(f, length=0.4, chamber_area=0.04, pipe_area=0.01,
                                         inlet_extension=0.1)
print(round(float(et.transmission_loss[np.argmin(abs(f - 428.75))]), 1))
# 0.6 dB at c/2L: the L/4 stub is tuned an octave above it
```

An extension is a quarter-wave stub buried inside the chamber, so its own
length decides which trough it fills: a stub of length $L_\text{ext}$ shorts
the duct at $c/4L_\text{ext}$. The plain 0.4 m chamber is transparent at
$c/2L = 429$ Hz and again at $c/L = 858$ Hz. The 0.1 m inlet extension ($L/4$)
is tuned to 858 Hz, so it shorts the second trough and leaves the first almost
untouched at 0.6 dB; the 0.2 m outlet extension ($L/2$) is the one tuned to
429 Hz, and the pair covers both. The trade is visible in the same figure: on
its own the inlet extension does not remove the trough it misses, it moves it,
to 444 Hz.

![Transmission loss from 20 to 880 Hz of a 0.4 m expansion chamber in three configurations: the plain chamber as a dashed pair of humps reaching 6.5 dB and falling to zero at 429 and at 858 Hz, the same chamber with a 0.10 m inlet extension which runs off the top of the plot at 858 Hz but reads only 0.6 dB at 429 Hz and keeps a trough there, moved to 444 Hz, and the chamber with both a 0.10 m inlet and a 0.20 m outlet extension which runs off the top at 429 and at 858 Hz and has no trough left in the band](https://docs.jmrp.io/phonometry/media/silencer_extended_tube.svg)

*What an internal extension buys, and what it costs. The plain chamber's 0 dB
troughs at every half wavelength are its fatal defect, and each extension
shorts exactly the one its own length tunes: $L/2$ takes the first, $L/4$ the
second. A single extension therefore moves the trough it misses rather than
removing it, which is why the extensions are sized in pairs and why an
extended-tube chamber is designed against the source spectrum rather than in
general.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# `f`, and extended_tube_chamber / expansion_chamber, as in section 1.
plain = noise_control.expansion_chamber(f, 0.4, 0.04, 0.01)
inlet = noise_control.extended_tube_chamber(f, 0.4, 0.04, 0.01, inlet_extension=0.1)
both = noise_control.extended_tube_chamber(f, 0.4, 0.04, 0.01, inlet_extension=0.1,
                                           outlet_extension=0.2)

# One line for one device:
inlet.plot()
plt.show()

fig, ax = plt.subplots()
for res, label in ((plain, "Plain chamber"), (inlet, "Inlet L/4"),
                   (both, "Inlet L/4 and outlet L/2")):
    ax.plot(f, res.transmission_loss, label=label)
ax.set_xlabel("Frequency [Hz]"); ax.set_ylabel("Transmission loss [dB]")
ax.set_ylim(0.0, 46.0)
ax.legend()
plt.show()
```

The extension is a real piece of pipe pushed into the chamber, and
`.plot_geometry()` draws it to scale like every other device on this page.

![To-scale cross-section of the extended-tube chamber: a 400 mm chamber of 225.7 mm equivalent diameter between inlet and outlet pipes of 112.8 mm equivalent diameter, with the inlet pipe pushed 100 mm into the chamber and the outlet pipe 200 mm, both dimensioned](https://docs.jmrp.io/phonometry/media/extended_tube_geometry.svg)

*The same 0.4 m chamber as above, with the inlet tube pushed 100 mm in and the
outlet 200 mm. Nothing is added on the outside: the two quarter-wave branches
are the annular spaces the extensions create.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# One line: the dimensioned cross-section of the device just computed.
noise_control.extended_tube_chamber(f, 0.4, 0.04, 0.01, inlet_extension=0.1,
                                    outlet_extension=0.2).plot_geometry()
plt.show()
```

![Transmission loss of a Helmholtz resonator and a closed quarter-wave tube on the same 10 cm2 duct: each side branch produces a sharp spike at its own tuning frequency, near 120 Hz for the Helmholtz volume and near 285 Hz for the 0.3 m tube, and is transparent elsewhere](https://docs.jmrp.io/phonometry/media/silencer_side_branch.svg)

*Each side branch shorts the duct at its own tuning frequency and is nearly
transparent elsewhere: the narrow spike is why resonators are matched to a
firing frequency or a fan blade-passing tone rather than used broadband.*

**Do not read the height of that spike.** Both branch models default to
`resistance=0.0`, so the branch is a perfect short at $f_0$ and the computed
transmission loss diverges there; what the figure shows is where the frequency
grid happened to land, which is why the by-hand code below has to clamp the axis
at 50 dB. What limits the peak in metal is the viscous loss in the neck, the
radiation from the cavity walls and any damping deliberately added. A well-made
resonator delivers something like 15 to 25 dB at its tuning frequency, over a
relative bandwidth set by its $Q$ and typically a few per cent, a fraction of
an octave. `resistance=` is where a measured or estimated acoustic resistance
goes, and adding it lowers and broadens the peak, which is the trade between
depth and tolerance to a tuning error. Read that beside the end-correction
warning above: a notch 22 % off its target is worth nothing, so the broader
damped design is usually the safer one.

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import noise_control

f = np.linspace(20.0, 600.0, 4000)
hr = noise_control.helmholtz_resonator(f, duct_area=0.01, neck_area=1e-4,
                                       neck_length=0.02, cavity_volume=1e-3)
qw = noise_control.quarter_wave_resonator(f, duct_area=0.01, length=0.3, branch_area=2e-3)

# One line for one device: TL vs frequency with the resonance marked.
hr.plot()
plt.show()

# By hand: both side branches on the same axes.
fig, ax = plt.subplots()
ax.plot(f, hr.transmission_loss, label="Helmholtz resonator")
ax.plot(f, qw.transmission_loss, "--", label="Quarter-wave tube")
for fr in (hr.resonances[0], qw.resonances[0]):
    ax.axvline(float(fr), ls=":", color="#2ca02c")
ax.set_xlabel("Frequency [Hz]"); ax.set_ylabel("Transmission loss [dB]")
ax.set_ylim(0.0, 50.0)
ax.legend()
plt.show()
```

Why is the notch only a few hertz wide at all? Because a resonator takes
time to work, and the clip below shows it doing so, on this page's own
0.30 m stub in a 2D FDTD duct. A side branch does not block the duct the
instant the tone arrives: it has to **charge**. Driven at the tuning
frequency, the pressure at the stub's closed end ratchets up over about six
periods to 8.2 times the incident wave (the lossless branch at exact
resonance would reach ten, twice the duct-to-branch area ratio); driven at
150 Hz the same stub settles at 1.5 times within a couple of periods and
never charges, which is the whole notch mechanism seen once; the charge
has the percent-wide bandwidth $f/Q$, while the lossless TL spike is
hertz-wide. The clip also
runs the trim procedure of the end-correction warning above on screen:
built at exactly the drilled 300 mm, the simulated device rings at
272.9 Hz rather than 285.8, an effective length $c/4f = 314$ mm, and it
still charges fully because the 4.7 % detuning sits inside the 13 % charge
bandwidth. No transmission loss is annotated anywhere on it: at the tuning
frequency the lossless model's TL is infinite, so a finite number there
would only be restating the frequency grid.

**Video:** [A quarter-wave side branch charging, on and off tune (2D FDTD)](https://docs.jmrp.io/phonometry/media/anim_fdtd_side_branch.webm): A 2D FDTD duct carrying the guide's 0.30 m closed quarter-wave stub, driven at the 285.8 Hz tuning frequency and at 150 Hz side by side, with the closed-end pressure of both runs traced below. On tune the pressure inside the stub ratchets up over about six periods to 8.2 times the incident wave; off tune it settles at 1.5 times immediately and never charges. An annotation reports that the built 300 mm stub rings at 272.9 Hz, an effective length of 314 mm, so a built device would be trimmed to tune.

Both branches are small hardware, and `.plot_geometry()` shows just how
small: the resonator of the 120 Hz spike is a 1 L cavity fed by a 1 cm²
neck only 2 cm long.

![To-scale cross-section of the side-branch Helmholtz resonator: a duct of 112.8 mm equivalent diameter with a narrow 11.3 mm neck, 20 mm long, opening into a 1 litre cavity drawn as its equal-volume cube on top of the duct, with the neck diameter, neck length and duct diameter dimensioned](https://docs.jmrp.io/phonometry/media/helmholtz_branch_geometry.svg)

*The whole 120 Hz notch hangs on a 1 L box and a 2 cm neck: the cavity is
drawn as its equal-volume cube, and the tuning moves as
$\sqrt{S_\mathrm{n}/(l_\mathrm{e} V)}$, so small errors in these dimensions shift the spike off
its target.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import noise_control

f = np.linspace(20.0, 600.0, 4000)
hr = noise_control.helmholtz_resonator(f, duct_area=0.01, neck_area=1e-4,
                                       neck_length=0.02, cavity_volume=1e-3)

# One line: the side branch drawn to scale, cavity as its equal-volume cube.
hr.plot_geometry()
plt.show()
```

The quarter-wave tube needs no cavity at all: the 285 Hz spike of the figure
above comes from a plain closed tube of the right length standing on the
same duct.

![To-scale cross-section of the quarter-wave side branch: a closed tube 300 mm long and 50.5 mm in equivalent diameter standing on a duct of 112.8 mm equivalent diameter, with the tube length, tube diameter and duct diameter dimensioned](https://docs.jmrp.io/phonometry/media/quarter_wave_geometry.svg)

*A quarter-wave stub is just a closed tube of the right length: 0.3 m of
pipe puts the spike at $c/4l_\mathrm{e} \approx 285\ \text{Hz}$, and the 20 cm² branch
area only sets how strongly the stub loads the duct.*

**Caution**

**Tune at the working temperature.**
Every frequency on this page is a wavelength condition, so all of them scale
directly with the speed of sound **in the working gas**: $kL = \pi/2$ for the
chamber, $c/4l_\mathrm{e}$ for the stub, and the $c$ in front of the Helmholtz square
root. For air, $c(T) = 343\sqrt{T/293}$ with $T$ in kelvin, so an exhaust at
500 °C (773 K) runs at about 557 m/s, a factor 1.62, and the 0.3 m stub cut for
285.8 Hz on cold-air values sings at 464 Hz once the pipe is hot. Pass the
working values: `speed_of_sound=` and `density=`, since the density scales
every characteristic impedance and therefore the insertion loss. The
`speed_of_sound=557.0` call in the section 1 snippet above is that retune, and
it prints 464.2 Hz for the same 0.3 m stub.

A mean flow shifts the notch further and lowers its depth, and the temperature
falls along a real tailpipe, so an exhaust resonator is checked at the hot and
cold extremes and accepted with margin rather than designed at one value.

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import noise_control

f = np.linspace(20.0, 600.0, 4000)
qw = noise_control.quarter_wave_resonator(f, duct_area=0.01, length=0.3, branch_area=2e-3)

# One line: the closed 0.3 m tube on its duct, to scale.
qw.plot_geometry()
plt.show()
```

Each returns a `ReactiveSilencerResult` with `transmission_loss`,
`insertion_loss` (when impedances are given), the compound `transfer_matrix`,
the `plane_wave_limit` of its widest cross section and `.plot()`. Layouts the four
constructors do not cover are chained element by element, either with the
bare `duct_matrix`, `shunt_matrix`, `cascade`, `transmission_loss` and
`insertion_loss`, or through `SilencerChain`, which makes the same calls and
keeps the geometry they were given.

That `plane_wave_limit` is the validity ceiling of everything on this page.
Above the first higher-order cut-on of the widest section several modes
propagate, each with its own axial wavenumber, and the computed peaks and
troughs do not survive; the result raises a `PlaneWaveWarning` when the analysis
grid runs past it. For the 0.04 m² chamber of the figures above the limit is
**890.8 Hz**, so the 2 kHz sweeps in the snippets are more than half outside the
model and the second and third peaks of the $m$-family figure should be read as
design shape rather than prediction. The cut-on analysis itself is on
[Duct-Borne Noise](https://docs.jmrp.io/phonometry/devices/noise-control/duct-path/#8-the-plane-wave-limit).

Three things about the hardware are outside the algebra and decide whether a
built device behaves like the curve. The **shell** of a chamber is a large
thin-walled radiator: if its own transmission loss is below the silencer's, the
sound leaves through the shell and the device delivers the shell's number, which
is the field version of the limiting insertion loss of section 3. The two
**area discontinuities carry end corrections**, exactly as a resonator neck
does, so the acoustic length exceeds the geometric one and the measured troughs
sit a little below the $c/2L$ printed here; cut-and-try tuning has to be
verified rather than trusted. And the expansion **regenerates flow noise at its
own outlet**, which puts a floor under the delivered spectrum that the
transmission loss says nothing about; that quantity is
`flow_noise_straight_duct` on the
[industrial noise-control page](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/)
and `silencer_self_noise` on the
[duct-path page](https://docs.jmrp.io/phonometry/devices/noise-control/duct-path/#4-what-the-system-puts-back).

`ReactiveSilencerResult` also files itself: `.report()` renders a one-page PDF
in the layout of a silencer performance sheet, with the method-basis line
naming the plane-wave four-pole method (Munjal Eq. (3.27); Bies §8.8-8.9), an
optional metadata header (client, device, test environment, instrumentation,
climate, date), the per-band table of the transmission loss (and of the
insertion loss when the impedances were given) beside those same curves, the
boxed mean transmission loss over the analysis bands together with the peak
value and the device kind, and an optional verdict against a declared minimum
mean transmission loss. Rendering needs reportlab and, for the embedded
figure, matplotlib (`pip install "phonometry[report,plot]"`); pass
`language="es"` for a Spanish fiche.

```python
import numpy as np
from phonometry import ReportMetadata, noise_control

# A 0.5 m chamber of area ratio m = 8, at the octave-band centres.
freqs = np.array([63.0, 125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0])
res = noise_control.expansion_chamber(freqs, length=0.5, chamber_area=0.08, pipe_area=0.01)
res.report(
    "silencer_fiche.pdf",
    metadata=ReportMetadata(
        specimen="Simple expansion-chamber muffler (m = 8, design case)",
        measurement_standard="Munjal Eq. (3.27) four-pole model",
        laboratory="Phonometry Reference Laboratory",
        requirement=6.0,            # minimum acceptable mean transmission loss
    ),
)                                   # mean and peak transmission loss (dB)
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [Reactive-silencer transmission-loss example report (PDF)](https://docs.jmrp.io/phonometry/media/reactive_silencer_example.pdf): One-page reactive-silencer fiche: a metadata header with the client, the expansion-chamber muffler of area ratio m = 8 as the noise source, the duct-system design study and the test date, the octave-band transmission-loss table running 7.5, 11.4, 9.9, 12.1, 3.2, 7.0 and 11.1 dB from 63 Hz to 4 kHz beside the same curve plotted against frequency, the boxed mean transmission loss TL = 8.9 dB with the peak transmission loss of 12.1 dB and the device named as an expansion chamber, a PASS verdict against the required minimum of 6.0 dB, and the note that the result is a plane-wave prediction from the declared geometry and not a measurement.

Reactive-silencer fiche (ReactiveSilencerResult.report), the mean transmission loss over the analysis bands with its peak value.

### Layouts of your own

Nothing above covers a two-chamber muffler, or a chamber with a stub welded
onto its inlet pipe. Those are cascaded element by element, and `SilencerChain`
does it through the same `duct_matrix`, `shunt_matrix` and `cascade` calls
while keeping what each element was handed, so the layout can be drawn as well
as computed and the drawing cannot drift from the model.

What such a drawing may show follows from what the elements declare, and the
two kinds of element declare very different amounts. `duct_matrix` is handed a
length and an area, so a duct is drawn to scale, dimensioned, and its steps
with it. `shunt_matrix` is handed an impedance, which fixes no length, no area
and no volume: the Helmholtz resonator and the quarter-wave stub of the
previous section present *the same kind of object* to the chain, and a
perforate or an open end would present another. So a branch is marked at the
station where it joins the run, lettered with its name and with the one thing
its impedance does say about itself, the frequency at which it is least, where
the branch bites hardest, and nothing about it is dimensioned. The ends of the
run are left open for the same reason: a chain is a list of elements, not a
statement about the pipes it sits between. Put those pipes in the chain as duct
elements and they are drawn too. A chain that holds no duct of positive length
has no geometry and no scale to draw at, so it raises rather than drawing one.

![To-scale cross-section of a hand-built silencer chain: 100 mm and 200 mm runs of 200 mm duct opening into a 400 mm shell 600 mm long and returning to 300 mm of 200 mm duct, with each run length, both bores and the 1200 mm overall length dimensioned, and two side branches marked by leaders at the stations where they join, one lettered as a quarter-wave stub with least impedance at 125 Hz and the other as a Helmholtz resonator at 242 Hz](https://docs.jmrp.io/phonometry/media/silencer_chain_geometry.svg)

*Every measurement on the page comes from what the chain was given: the four
duct lengths and their sum are the numbers themselves, and the two bores are
the areas it was handed, restated as the equivalent circular diameter
$d = 2\sqrt{S/\pi}$. The two branches carry no dimension at
all, because an impedance is not a shape.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import noise_control
from phonometry.noise_control import helmholtz_impedance, quarter_wave_impedance

freqs = np.linspace(20.0, 500.0, 481)
s_duct = np.pi * 0.100**2               # nominal 200 mm duct
s_shell = np.pi * 0.200**2              # nominal 400 mm shell

# The elements in order, inlet to outlet; each call keeps what it was given.
chain = (
    noise_control.SilencerChain(freqs)
    .duct(0.10, s_duct)
    .shunt(quarter_wave_impedance(freqs, 343.0 / (4.0 * 125.0), np.pi * 0.050**2),
           label="Quarter-wave stub")
    .duct(0.20, s_duct)
    .duct(0.60, s_shell)
    .shunt(helmholtz_impedance(freqs, np.pi * 0.025**2, 0.05, 2e-3),
           label="Helmholtz resonator")
    .duct(0.30, s_duct)
)

# One line: the chain drawn exactly as it was declared.
chain.plot_geometry()
plt.show()

# The same elements evaluated: `.result()` gives the compound matrix, the
# transmission loss, the plane-wave limit of the widest section, .plot() and
# .report(), and `.transfer_matrix` alone is what `cascade` would have built.
res = chain.result(inlet_area=s_duct, outlet_area=s_duct)
res.plot()
plt.show()
```

## 2. Reactive or dissipative?

Everything above works by reflection, and reflection has a shape: sharp,
periodic, frequency-selective. The complementary family, **dissipative**
silencers, replaces the impedance discontinuities with a duct section whose
walls are lined with porous material (often protected by a perforated
facing), so the grazing wave loses energy to viscous friction in the lining
instead of being sent back to the source. The behaviours differ where it
matters for selection:

- **Frequency reach.** A reactive chamber or resonator is strongest exactly
  where it is tuned and transparent elsewhere; a lined duct attenuates over
  a broad band that peaks where the lining depth is comparable with a
  quarter wavelength. At low frequency a practical lining is acoustically
  thin and does little, which is the regime where the reactive chamber
  wins; at high frequency the sound beams down the open airway and passes
  over the lining, so the attenuation of both families collapses and only
  splitter geometries (narrow airways, more lined perimeter per unit area)
  keep working.
- **Spectrum type.** A tonal source, an engine firing order or a
  blade-passing frequency, is a resonator's natural prey; broadband fan or
  flow noise wants the dissipative band. Production exhaust silencers
  routinely combine the two, packing an expansion chamber with fibre so the
  reflective troughs of the chamber are filled by absorption.
- **The medium.** A porous lining in a hot, sooty or pulsating exhaust
  clogs and degrades, one reason vehicle exhausts are predominantly
  reactive; clean HVAC air is where dissipative attenuators and lined
  plenums are the default. In either case the airflow adds its own floor:
  a silencer regenerates flow noise at its own outlet, and past a certain
  pressure drop the silencer becomes the noise source.

Those are three frequency-dependent claims, so here they are on one axis, every
curve computed from the shipped models rather than sketched.

![Attenuation from 40 Hz to 8 kHz for five devices. In blue, the reactive family: the 0.3 m expansion chamber, a broad hump reaching 6.5 dB with a zero at 572 Hz, and a Helmholtz branch tuned to 100 Hz, a spike a few hertz wide reaching 18 dB and nothing elsewhere. In green, 1.5 m of lined 36 by 24 inch duct with 25 mm and with 50 mm of lining, both rising through the mid bands to 12.6 and 13.6 dB and falling slowly above. In red, a five-airway splitter unit, from 10.7 dB at 63 Hz to 40 dB at 500 Hz and back to 12.1 dB at 8 kHz. A dotted vertical line at 891 Hz marks the first duct cut-on, beyond which the blue four-pole curves are not drawn](https://docs.jmrp.io/phonometry/media/silencer_selection.svg)

*The selection rule, drawn. The resonator wins only where the tone is, and is
transparent two semitones away. The chamber is worth a few decibels over a broad
low band and nothing at all at its own half-wave troughs. A practical lining
does almost nothing at 63 Hz (1.2 dB for 25 mm over 1.5 m) and doubling the
lining thickness buys 7 dB at 500 Hz and nothing above 1 kHz, because there the
sound already beams down the open airway. Only the splitter, which narrows the
airway and multiplies the lined perimeter, keeps 30 dB through the middle. The
blue curves stop at 891 Hz because that is where their model does.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# The reactive side, drawn only as far as its own validity ceiling.
chamber = noise_control.expansion_chamber(f, 0.3, 0.04, 0.01)
inside = f <= chamber.plane_wave_limit

fig, ax = plt.subplots()
ax.semilogx(f[inside], chamber.transmission_loss[inside],
            label="Expansion chamber, m = 4")
ax.semilogx(f[inside], hr.transmission_loss[inside],
            "--", label="Helmholtz branch")
ax.set_xlabel("Frequency [Hz]"); ax.set_ylabel("Attenuation [dB]")
ax.legend()
plt.show()
```

The dissipative curves come from the installation models of the
[HVAC methods](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/), not from this
module: `hvac.lined_rectangular_duct_attenuation(bands, 36 in, 24 in, 1.5 m, t,
include_unlined=True)` for the two linings, and
`hvac.splitter_silencer_insertion_loss(bands, 24 in, 5 ft, [4 in] * 5, 8 in)`
for the splitter unit.

phonometry models the reactive family in closed form on this page. The
dissipative side enters at installation level, through the
[HVAC methods](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/): the lined-elbow
insertion loss read from tabulated ASHRAE data and the lined plenum
attenuation from Wells' closed form, neither of them a liner model. The
porous physics that
a first-principles liner calculation needs, the equivalent-fluid models fed
by the airflow resistivity, is the same material theory as
[Porous and Multilayer Absorbers](https://docs.jmrp.io/phonometry/materials/absorbers/porous-absorbers/).

## 3. How a silencer is measured (ISO 7235)

Everything above is computed from geometry. The figure a supplier publishes is
not: it is an **insertion loss measured by substitution**, and ISO 7235:2003
(published in Europe as EN ISO 7235:2009) is the method behind it. Reading the
page's fiche without knowing that is how a computed 8.9 dB and a catalogue
"25 dB" end up in the same sentence.

![Two stacked runs on one duct axis. In the upper run, series one, a sealed and lined loudspeaker box feeds a modal filter, then a transition, then the test object, then a test duct with an anechoic wedge termination carrying three microphone positions on a line inclined to the duct axis. The lower run, series two, is identical except that the test object is replaced by an empty substitution duct. Dashed qualification planes are marked at the test object and at the receiving duct. Below, the insertion loss is given as the difference of the two receiving-side levels, third octave by third octave, with the modal-filter attenuation, the reflection-coefficient limit, the substitution-duct tolerance and the signal-to-background rule listed as the standard's own clause numbers](https://docs.jmrp.io/phonometry/media/diagram_silencer_iso7235.svg)

The rig has four parts and each of them carries a requirement. The **source**
is a random-noise generator and amplifier driving loudspeakers in an
acoustically sealed, absorbent-lined box, with pressure-equalisation openings
for flow tests, powerful enough that every measurement point sits at least 6 dB
and preferably 10 dB above the background (clause 5.2.2.2). A **modal filter**
follows: a duct section with absorptive or reactive elements that attenuates the
fundamental a little and higher-order modes a lot, at least 3 dB on the
fundamental at the low-frequency end and at least 5 dB above the cut-on of
higher-order modes, which also decouples the source from the test object
(5.2.2.3). A rigid **transition element** joins them without radiating breakout
noise (5.2.2.4). And the **substitution duct** is non-absorbent, ideally the
empty housing of the test object itself, otherwise matched to its inlet and
outlet within 5 % in every linear dimension (5.2.3).

The receiving side is one of three (5.2.4). A **reverberation room** to
ISO 3741, qualified at least down to the 125 Hz third octave, is the preferred
arrangement. A **test duct with an anechoic termination** is the fallback: at
least half a wavelength of the lowest band long and at least four times the
maximum cross dimension, with a reflection coefficient no greater than 0.3, and
microphones plus fixtures obstructing under 5 % of the duct area. **Essentially
free-field conditions** at the open end are allowed when the direct sound
exceeds the strongest reflection by 10 dB, which holds when the nearest
reflecting surface is more than twice as far away as the microphone.

The procedure is then two series with nothing else changed. $L_{p\mathrm{I}}$ is
determined with the test object installed, $L_{p\mathrm{II}}$ with the substitution duct
in its place, at identical points or paths and with an unchanged source
spectrum, and the insertion loss is $D_\mathrm{i} = L_{p\mathrm{II}} - L_{p\mathrm{I}}$ third octave by
third octave (6.2.1). In a test duct the spatial average takes **at least three
equally spaced positions** on a line inclined to the duct axis at about half its
length, spanning at least a quarter wavelength of the lowest band, going to five
when the spread between the three exceeds the Table 6 limits: 10 dB at 50 and
63 Hz, 8 dB at 80 and 100 Hz, 7 dB at 125 Hz and 6 dB above 160 Hz. The chain is
class 1 with IEC 61260 third-octave filters (5.2.4.6) and is verified with a
class 1 calibrator to $\pm 0.3$ dB before and after each series (6.1).

Two consequences travel with the number. First, what is reported is an
**insertion loss against a substitution duct**, not a transmission loss, so it
is not the quantity this page computes and the two must not be compared
directly. Second, every facility has a **limiting insertion loss**, the ceiling
set by flanking along its own duct walls, measured with the substitution duct
acoustically blocked, and recorded as a function of frequency (7.4). A very
large catalogue figure is a claim about the test arrangement as much as about
the device, which is why the arrangement is reportable at all. For orientation
on how repeatable any of this is, the standard's own reproducibility standard
deviations for insertion loss are 1.5 dB from 50 to 100 Hz, 1 dB from 125 to
500 Hz, 2 dB from 630 Hz to 1.25 kHz and 3 dB above (Table 7), with the expanded
uncertainty twice those values.

Two neighbouring standards complete the picture: **ISO 11691** is the survey-
grade laboratory method without flow, and **ISO 11820** measures a silencer in
situ, where the substitution trick is usually impossible. The arithmetic of
the first two, the subtraction itself and the tables that go with it, is on
[Measuring a Silencer](https://docs.jmrp.io/phonometry/devices/noise-control/silencer-measurement/).

## Cross-check against the FDTD solver

That cross-check is the clip embedded in section 1, and it is worth returning
to it now with the algebra in hand. The four-pole expansion chamber is checked
against the independent 2D
[FDTD wave solver](https://docs.jmrp.io/phonometry/simulation/fdtd-simulation/), which shares no
formula and no assumption with the transfer-matrix product beyond the wave
equation itself: a plane-wave duct that widens into the same 0.30 m, $m = 4$
chamber and narrows back transmits far less at the four-pole TL peak
($kL = \pi/2$, here 286 Hz) than at the transparent trough ($kL = \pi$,
572 Hz). The amplitude ratio measured downstream in the field is the
transmission loss annotated on the clip, 6.5 dB at 286 Hz and 0.0 dB at
572 Hz, against the 6.55 dB the closed form gives for $m = 4$. Agreement that
close rules out an algebra error on either side. The two must eventually part
company above the duct's first cut-on frequency, where higher-order modes
propagate: the two-dimensional solver keeps working there and the plane-wave
algebra does not.

## What this guide covers

- **Covered.** Reactive silencers by the four-pole transfer-matrix method (Bies §8.8-8.9,
  Munjal Eq. (3.27)): the closed-form `expansion_chamber` (Eq. (8.111)),
  `helmholtz_resonator` and `quarter_wave_resonator` (Eqs. (8.46), (8.44)),
  `extended_tube_chamber`, and the `duct_matrix`/
  `shunt_matrix`/`cascade`/`transmission_loss`/`insertion_loss` building blocks
  for arbitrary element chains, gathered by `SilencerChain` into a chain that
  keeps its geometry; the to-scale `.plot_geometry()` drawing on each of the
  four constructors' results and on a chain, and the expansion chamber
  cross-checked against the independent FDTD solver; the
  `plane_wave_limit` that bounds all of them; and, as prose rather than as code,
  the ISO 7235 substitution measurement that produces the insertion loss a
  supplier publishes, whose arithmetic is on [its own
  page](https://docs.jmrp.io/phonometry/devices/noise-control/silencer-measurement/).

- **Not covered.** Only reactive elements are computed: dissipative (absorptive, duct-lining)
  silencers are discussed for selection but not modelled from the liner
  properties, and in the [HVAC
  methods](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/) the lined-elbow
  figure is a table lookup (Bies Table 8.11) and the plenum attenuation is
  Wells' closed form driven by a declared mean absorption; neither is a liner model.
  Mean-flow effects (convection,
  temperature gradients, flow-dependent impedance of perforates) are outside the
  no-flow element matrices used here. Nothing on this page is a measurement: the
  arithmetic of ISO 7235 has [a page of its
  own](https://docs.jmrp.io/phonometry/devices/noise-control/silencer-measurement/), the shell
  breakout and the end corrections at the area jumps are not modelled, and the
  branch models are lossless unless a `resistance` is supplied.

## See also

- [Duct-Borne Noise: Fan to Room](https://docs.jmrp.io/phonometry/devices/noise-control/duct-path/): the
  end-to-end fan-to-room calculation these silencers sit inside, and the
  higher-order-mode cut-on above which the four-pole method describes the
  plane-wave mode alone.
- [Industrial noise control](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/): the rest
  of the installation: HVAC duct attenuation and flow noise, plenums, end
  reflection and machine enclosures.
- [2D FDTD wave simulation](https://docs.jmrp.io/phonometry/simulation/fdtd-simulation/): the
  independent solver behind the expansion-chamber cross-check.
- [Porous and Multilayer Absorbers](https://docs.jmrp.io/phonometry/materials/absorbers/porous-absorbers/):
  the equivalent-fluid material theory behind dissipative linings.
- [Loudspeaker Characterisation (IEC 60268-5)](https://docs.jmrp.io/phonometry/devices/electroacoustics/loudspeakers/):
  the radiating piston, the companion radiator model of a duct's open end.
- API reference: [`noise_control.silencers`](https://docs.jmrp.io/phonometry/reference/api/noise_control/silencers/).

## References

- **Bies, D. A., Hansen, C. H., & Howard, C. Q. (2017).** *Engineering noise control* (5th ed.). CRC Press. https://doi.org/10.1201/9781351228152
  The muffler four-pole method, the expansion-chamber TL and the resonator tuning formulas (§8.8-8.9) of this guide.
- **International Organization for Standardization. (2003).** [*Acoustics — Laboratory measurement procedures for ducted silencers and air-terminal units — Insertion loss, flow noise and total pressure loss*](https://www.iso.org/standard/30385.html) (ISO 7235:2003).
  The substitution measurement of section 3: the source, modal filter, transition and substitution duct of Clause 5.2, the three receiving-side arrangements of 5.2.4, the two series of 6.2.1 with the Table 6 spread limits, and the limiting insertion loss of Clause 7.4 and Annex C. Europe adopts it unchanged as EN ISO 7235:2009.
- **Munjal, M. L. (2014).** *Acoustics of ducts and mufflers* (2nd ed.). Wiley. https://doi.org/10.1002/9781118443767
  The transfer-matrix formulation, the element matrices and the transmission loss from the compound matrix (Eq. (3.27)), and the reference treatment of dissipative and combined mufflers.
- **Vér, I. L., & Beranek, L. L. (2006).** *Noise and vibration control engineering: Principles and applications* (2nd ed.). Wiley. https://doi.org/10.1002/9780470172568
  The companion treatment of reactive and dissipative silencers.