# Measuring a Silencer (ISO 7235 and ISO 11691)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/noise-control/silencer-measurement/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/noise-control/silencer-measurement/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-07
Updated: 2026-11-16T21:36:14Z
Standards: ISO 7235:2003; ISO 11691:1995; ISO 5135:1997
Verified: 23 conformance checks (ISO 7235:2003; ISO 11691:1995; ISO 5135:1997) https://docs.jmrp.io/phonometry/reference/conformance/#ducted-silencer-measurement-iso-7235-iso-11691
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Catalogue insertion loss of a silencer: the ISO 7235 substitution measurement, its survey sibling ISO 11691, the octave fold and repeatability.

---

Everything a silencer model computes comes from geometry. The figure a
supplier publishes does not. It is an **insertion loss measured by
substitution**: the same rig run twice, once with a plain duct where the
silencer will go and once with the silencer in it, and the difference between
the two receiving-side levels, band by band. Reading a catalogue without
knowing that is how a computed 8.9 dB and a published "25 dB" end up in the
same sentence.

Two standards describe the measurement, and they differ in scope as much as
in what they ask of the laboratory. **ISO 7235:2003** is the full procedure,
with a modal filter decoupling the source, a qualified receiving side and a
stated measurement uncertainty, and it covers silencers, air-terminal units
and other duct elements, with flow and without. **ISO 11691:1995** is six
printed pages carrying two equations, and it measures silencers and nothing
else, without flow and with none in the answer, up to a design velocity of
15 m/s. A measurement that needs flow, or an object that is not a silencer,
is outside ISO 11691 and belongs to ISO 7235.

![Three panels. Left: two groups of bars, one for a silencer that is flat across an octave and one whose worst third leaks, each showing the three one-third-octave insertion losses as pale bars, the octave that Equation (2) gives as a filled bar and the plain mean of the decibels as a dashed line; in the flat group the two agree and in the leaky one the octave sits twelve decibels under the mean. Middle: the open-end transmission loss of a 350 mm duct against frequency on a logarithmic axis, drawn for the three distinct solid angles of Table B.1 and for Long's rival closed form, all falling from about fifteen decibels at 50 Hz to nothing above 2 kHz, with the free-space curve the highest of the three. Right: the reproducibility standard deviations of both standards as step functions of frequency, the insertion-loss column dipping to one decibel in the middle of the range, the transmission-loss column flat at three, the sound-intensity column falling to one and stopping at 5 kHz, and the survey method stepping from two to three](https://docs.jmrp.io/phonometry/media/silencer_measurement.svg)

*The three things a measurement report carries beyond the numbers themselves:
how its octaves were folded, what its duct mouth was keeping in, and how far
any of it can be trusted.*

## 1. One subtraction, two numberings

![Two stacked runs on one duct axis. In the upper run, series one, a sealed and lined loudspeaker box feeds a modal filter, then a transition, then the test object, then a test duct with an anechoic wedge termination carrying three microphone positions on a line inclined to the duct axis. The lower run, series two, is identical except that the test object is replaced by an empty substitution duct. Dashed qualification planes are marked at the test object and at the receiving duct. Below, the insertion loss is given as the difference of the two receiving-side levels, third octave by third octave, with the modal-filter attenuation, the reflection-coefficient limit, the substitution-duct tolerance and the signal-to-background rule listed as the standard's own clause numbers](https://docs.jmrp.io/phonometry/media/diagram_silencer_iso7235.svg)

*The two series are the whole method: everything else in both standards is
about making sure nothing but the test object changed between them.*

The measurement is the same in both:

$$
D_\mathrm{i} = L_{W\mathrm{II}} - L_{W\mathrm{I}}
$$

with $\mathrm{I}$ the series that had the test object and $\mathrm{II}$ the
series that had the substitution duct. ISO 11691 writes the identical thing
as $D = L_{p1} - L_{p2}$, and numbers the two series **the other way round**:
its 1 is the substitution duct. Two standards for one measurement, with
opposite subscripts, is exactly the sort of thing that gets entered backwards,
so the arguments here are named for what was in the duct rather than for
either numbering.

```python
from phonometry import noise_control

substitution = [88.0, 90.0, 91.0, 92.0, 92.0, 91.0]   # dB, empty duct
with_silencer = [84.0, 83.0, 79.0, 72.0, 66.0, 63.0]  # dB, silencer fitted

d_i = noise_control.substitution_insertion_loss(substitution, with_silencer)
print(d_i)                        # [ 4.  7. 12. 20. 26. 28.] dB
```

If the receiving room's absorption moved between the two series, that
difference is not yet the insertion loss. Clause 6.3 puts it right with
$10\lg(T_2/T_1)$, where $T_2$ is the reverberation time measured with the
test object installed. A room that got **deader** while the silencer was in it
was flattering the silencer, and the correction takes that back:

```python
corrected = noise_control.substitution_insertion_loss(
    substitution, with_silencer, reverberation_times=(2.1, 1.8),
)
print(corrected.round(2))         # [ 3.33  6.33 11.33 19.33 25.33 27.33] dB
```

Clause 6.3 also allows $T_2 = T_1$ outright when the test object sits outside
the room, and then the pair can be left out.

## 2. What the number is not

It is not a transmission loss. It is measured against a particular
substitution duct in a particular rig, and it carries that rig with it in two
ways worth naming.

The first is the **limiting insertion loss**: sound flanks along the duct
walls rather than through the silencer, and no arrangement can measure past
what its own flanking lets round. ISO 7235 has the laboratory measure that
ceiling with the substitution duct acoustically blocked and record it as a
function of frequency (7.4). A very large catalogue figure is a claim about
the test arrangement as much as about the device.

The second is the receiving side, which decides how much of the sound the
microphones see at all. ISO 7235 allows three (5.2.4): a reverberation room
to ISO 3741 qualified at least down to the 125 Hz one-third octave, which is
preferred; a test duct with an anechoic termination whose reflection
coefficient is no greater than 0.3; or essentially free-field conditions at
the open end. ISO 11691 keeps only the reverberation room and the free-field
alternatives, and asks for 3.5 m of duct on each side of the silencer.

None of that is arithmetic, which is why the rest of this page is short. The
arithmetic that remains is the part a reader can get wrong on paper.

## 3. Octaves are folded on the energy, not on the decibels

A measurement is made in one-third octaves and often reported in octaves.
ISO 11691 Equation (2) says how, and it is not an average of the three
numbers:

$$
D_\mathrm{oct} = -10 \lg\left[\frac{1}{3}\left(
   10^{-D_1/10} + 10^{-D_2/10} + 10^{-D_3/10}
\right)\right]\ \text{dB}
$$

The average is taken on what the silencer **lets through**. That matters
because a silencer is rarely flat across an octave, and the band that leaks
decides the answer:

```python
thirds = [4.0, 7.0, 12.0, 20.0, 26.0, 28.0]
print(noise_control.octave_insertion_loss(thirds).round(2))
#                                 # [ 6.57 23.28] dB
```

The plain arithmetic means of the same two groups are 7.67 and 24.67 dB, so
reading the decibels rather than the energy would have overstated both
octaves by about a decibel. On a steeper silencer the gap is larger: three
thirds of 30, 30 and 5 dB give **9.7 dB** over the octave, not 21.7. Almost
all the transmitted sound is coming through the one band that does not work,
and Equation (2) is written out rather than described precisely so that this
cannot be got wrong.

ISO 11691 states the assumption it rests on: the sound pressure levels of the
three one-third octaves are taken to be equal in the series run with the
substitution duct, which is what lets their energies be weighted equally.

## 4. Three microphone positions, or five

In a test duct the spatial average comes from at least three microphone
positions equally spaced on a line across the duct, spanning at least a
quarter wavelength of the band, about half way along the duct. Three is
enough only if the three agree. ISO 7235 Table 6 says how closely, and if the
highest and lowest differ by more than that, five positions shall be used:

```python
levels = [70.0, 74.0, 79.0]       # dB at the three key positions
print(noise_control.microphone_spread_limit(125.0))     # 7.0 dB
print(noise_control.microphone_positions_required(levels, 50.0))    # 3
print(noise_control.microphone_positions_required(levels, 125.0))   # 5
```

The same three levels are acceptable at 50 Hz, where the limit is 10 dB, and
not at 125 Hz, where it is 7. The limit falls with frequency because a duct
at low frequency has a standing-wave pattern that three points sample badly,
and at high frequency does not.

One thing to know about Table 6: its rows read 50, 63, 80, 100, 125 and then
`> 160` Hz, so the **160 Hz one-third octave belongs to no row** and is given
no limit at all. Every other row names a single band, and 160 Hz is a
one-third-octave centre like the rest, so it is read here as belonging to the
last row. The gap is in the [errata
register](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md).

## 5. How repeatable any of this is

Both standards answer, and neither answer is flattering.

ISO 11691 says outright that exact information on the precision of its method
cannot be given, that interlaboratory tests would be needed for a real
reproducibility standard deviation, and that this is what makes it a survey
standard. Its Table 1 offers an estimate only: 2 dB up to the 1.25 kHz
one-third octave and 3 dB above it.

ISO 7235 Table 7 has three columns, and the disagreement between them is the
useful part:

```python
for band in (50.0, 250.0, 1000.0, 4000.0):
    print(band, [
        noise_control.measurement_reproducibility(band, quantity=q)
        for q in ("insertion_loss", "transmission_loss", "intensity")
    ])
# 50.0   [1.5, 3.0, 3.0]
# 250.0  [1.0, 3.0, 1.5]
# 1000.0 [2.0, 3.0, 1.0]
# 4000.0 [3.0, 3.0, 1.0]
```

Insertion loss is measured best in the middle of the range and worst at the
top; the sound-intensity route runs the other way; transmission loss is a
flat 3 dB everywhere. Clause 7.9 explains why: only the insertion-loss column
came from tests, on 1 m long parallel-baffle silencers, and the other two rest
on experience. A column that does not move with frequency is the shape of an
estimate, not of a measurement.

What goes on the report is twice the table value, for a coverage probability
of 95 %:

```python
print(noise_control.measurement_expanded_uncertainty(250.0))    # 2.0 dB
print(noise_control.measurement_expanded_uncertainty(4000.0))   # 6.0 dB
```

A silencer quoted at 25 dB in the 4 kHz band is being quoted to within 6 dB.

## 6. The scope ISO 11691 draws round itself

The survey method is deliberately narrow, and its limits are published rather
than implied. The design velocity may not exceed 15 m/s, because the method
runs the rig with no flow at all and so includes none of the self-generated
noise. It is written for circular silencers from 80 mm to 2 m in diameter, or
rectangular ones of comparable area. And the test ducts have to be close in
cross section to what they feed, between 0.6 and 1.7 times the area of the
silencer or the substitution duct (4.5). Outside that, the joints reflect more
than the method allows for, and the library says so:

```python
print(noise_control.substitution_area_ratio(0.0962, 0.0962))    # 1.0
print(noise_control.SURVEY_MAX_VELOCITY_M_S)                    # 15.0
print(noise_control.SURVEY_AREA_RATIO_RANGE)                    # (0.6, 1.7)
```

## 7. The open end, and the two quantities that need it

A duct radiating into a room does not hand the room everything that reaches
its mouth. Well below the frequency at which the mouth is a wavelength across
it is a poor radiator, and most of the energy turns round and travels back up
the duct. Annex B.3 puts a number on it:

$$
D_\mathrm{td} = 10 \lg\left[1 +
   \frac{\Omega}{\left(\dfrac{4\pi f \sqrt{S}}{c}\right)^{2}}\right]\ \text{dB}
$$

The group $4\pi f \sqrt{S} / c$ is the mouth measured in wavelengths, and
$\Omega$ is the solid angle it radiates into. A 350 mm duct flush with a wall
holds back 11 dB at 63 Hz and 0.05 dB at 2 kHz, which is nothing:

```python
import numpy as np

bands = np.array([63.0, 125.0, 250.0, 500.0, 1000.0, 2000.0])
area = 0.0962                     # m2, a 350 mm circular duct

d_td = noise_control.open_end_transmission_loss(bands, area)
print(d_td.round(2))              # [11.23  6.14  2.5   0.77  0.21  0.05] dB
```

![Five cells in a row, one for each mounting configuration of ISO 7235 Table B.1. In each, a small square terminal sits at the origin of a shaded wedge that is the solid angle read in section: a half circle against a wall for A, a quarter circle in the corner of a wall and a floor for B, a full circle standing free for C, a half circle above a floor for D, and a full circle again for E. Below each, the solid angle: two pi, pi, four pi, two pi and four pi. Under the row, the formula written both as ISO 7235 prints it and as ISO 5135 prints it, a note that the two are one formula with the same five values, and the conclusion that the bigger the solid angle the more the mouth keeps in](https://docs.jmrp.io/phonometry/media/diagram_open_end_solid_angles.svg)

*The solid angle is the only term of Equation (B.3) a laboratory chooses
rather than measures, and the five choices are the same in both standards.*

The solid angle is Table B.1, and the same five values are Table 1 of
ISO 5135. It works the way round that surprises people: $\Omega$ sits in the
numerator, so a duct ending in the middle of the room keeps **more** sound in
than one flush with a wall, not less. A baffle is what makes an opening a good
radiator, because it stops the pressure relieving round the rim of the mouth,
and an unbaffled end of the same size sends more of the sound back up the
duct:

```python
free = noise_control.open_end_transmission_loss(
    bands, area, solid_angle_sr=noise_control.RADIATION_SOLID_ANGLES["C"],
)
print(free.round(2))              # [14.07  8.59  4.08  1.43  0.4   0.1 ] dB
```

Three more decibels at 63 Hz, and the reflection coefficient rises with it.

**Video:** [The open end of a duct in a 2D FDTD simulation](https://docs.jmrp.io/phonometry/media/anim_fdtd_open_end.webm): A 0.20 m duct flush in a rigid screen, radiating into the half space beyond it, driven at 100 Hz and at 800 Hz one above the other. At 100 Hz the duct fills with a standing wave and only a faint field escapes past the screen; the envelope beside it swings between a maximum and a minimum that give a reflection coefficient of 0.71. At 800 Hz the duct carries a nearly travelling wave and strong circular fronts leave the mouth into the half space, with an envelope that ripples only slightly and gives 0.19.

*Both carriers are below the 857 Hz cut-on of a duct that wide, so the field
inside it is the plane wave the whole of ISO 7235's duct arithmetic assumes.
The reflection coefficients read off the standing wave are the simulated
geometry's own, and not Equation (B.4): that closed form is a piston
approximation for a circular mouth, where this is a slit in a screen. What
the two share is the mechanism, and it is the mechanism that decides whether
a level measured in a room is the level in the duct behind it.*

Equation (B.4) says the same fact the other way round, as a pressure
reflection coefficient, and the two close exactly on the energy:
$D_\mathrm{td} = -10\lg(1 - r^2)$ at every frequency, area and solid angle.
That identity is the conformance anchor for both, because neither is printed
with a worked value. It also has a use of its own: 5.2.4 qualifies a test
duct as anechoic only below $r = 0.3$, which this bare open end reaches
somewhere between 500 Hz and 1 kHz.

```python
r = noise_control.open_end_reflection_coefficient(bands, area)
print(r.round(3))                 # [0.962 0.87  0.662 0.404 0.215 0.11 ]
```

The library carries a second closed form for the same physics, Reynolds' as
given by Long, in
[`end_reflection_loss_closed_form`](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/).
It raises the same argument to 1.88 rather than to 2, and for a circular duct
in free space the two read $10\lg[1 + (c/\pi f d)^2]$ against
$10\lg[1 + (c/\pi f d)^{1.88}]$. They agree closely where the argument is
near 1 and part company at the ends of the range.

Two quantities need it. Equation (6) turns the measured insertion loss of an
air-terminal unit into its transmission loss by putting back what the mouth
was keeping in anyway, so the two are the same number at the top of the range
and eleven decibels apart at the bottom:

```python
d_i = np.array([4.0, 7.0, 12.0, 20.0, 26.0, 28.0])
print(noise_control.measured_transmission_loss(d_i, d_td).round(2))
#                                 # [15.23 13.14 14.5  20.77 26.21 28.05] dB
```

And Equation (7) makes the flow noise a sound power,
$L_W = \overline{L_p} + D_\mathrm{td} + C$, where $C$ is the ISO 3741 level
difference between the power radiated into the room and the average pressure
in it. Clause 6.4 is explicit that $\overline{L_p}$ goes in **without** a
background correction: the two series are reported separately and the reader
subtracts them.

## 8. Where higher-order modes start

The modal filter between the source and the test object exists to stop
higher-order modes reaching the silencer, and its requirement steps at the
frequency where those modes can propagate in the connected ducts: at least
3 dB of longitudinal attenuation of the fundamental at the low-frequency end,
and at least 5 dB above that frequency (5.2.2.3). NOTE 2 prints where it is:

```python
print(round(noise_control.modal_filter_cut_on(diameter_m=0.4), 1))          # 505.9 Hz
print(round(noise_control.modal_filter_cut_on(larger_dimension=0.5), 1))  # 343.0 Hz
```

The rectangular form, $0.5\,c/H$, is exact: the first mode of a rigid
rectangular duct is a half wavelength across the larger dimension. The
circular one, $0.59\,c/d$, is rounded. The exact coefficient is the first
zero of $J_1'$ over $\pi$, which is 0.58607, so Equation (4) sits 0.67 %
high: on the 0.4 m duct of the ISO 11691 sound source that is 505.9 Hz where
[`circular_duct_cut_on`](https://docs.jmrp.io/phonometry/devices/noise-control/duct-path/) gives
502.6 Hz. Three and a half hertz does not matter for choosing a modal filter,
and it is worth knowing which of the two numbers is the physics.

## 9. What the object costs to push air through

The third thing ISO 7235 measures has nothing to do with sound. A silencer
that works and costs a fan half its pressure is not a good silencer, so 6.5
measures the **total pressure loss coefficient**, and the whole point of the
coefficient rather than the loss is that a loss means nothing without the flow
it was measured at.

Start with the air. Equation (10) is the ideal gas law with the standard's own
constants, and the static pressure it takes is a gauge pressure against the
ambient, so the two add:

```python
rho = noise_control.normal_air_density(200.0, 101325.0, 20.0)
print(round(rho, 4))              # 1.2073 kg/m3

q_v = noise_control.volume_flow_rate(1.2, rho)
print(round(q_v, 4))              # 0.9939 m3/s
```

ISO 7235 prints $R = 287$ and writes the absolute temperature as
$\theta + 273\ ^\circ\text{C}$, neither of which is the accurate figure. The
offset alone puts the density 0.051 % high at 20 °C, and the gas constant adds
0.017 % to that, for 0.069 % in all. It does not cancel: the same density is
in the dynamic pressure of both test series, so the coefficient is **scaled**
by that one factor rather than shifted, and comes out 0.069 % low. That is far
under the uncertainty of a pressure-loss test, and using the printed constants
is what reproduces a result computed to the standard, so the library keeps
both. It is recorded in the [errata
register](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md) as
a property of the source rather than as a defect.

Equation (9) rather than (8) is used when the flow meter and the test object
are far enough apart in temperature or pressure that their density ratio
leaves 0.98 to 1.02: outside that window the meter is not measuring the flow
the test object sees.

The velocity head is Equation (13), and the coefficient is the loss divided by
it:

```python
p_d1 = noise_control.dynamic_pressure(q_v, 0.0962, rho)
print(round(p_d1, 2))             # 64.44 Pa

delta_p_t = noise_control.total_pressure_loss(45.0, p_d1, 0.0962, 0.0962)
print(round(noise_control.pressure_loss_coefficient(delta_p_t, p_d1), 3))
#                                 # 0.698
```

That number belongs to the object rather than to the test point, at least to
the extent the flow is dynamically similar: a loss grows as the square of the
velocity and so does the head it is divided by, so the algebra returns the
same coefficient at twice the flow. Real flow is not exactly similar, because
doubling the rate doubles the Reynolds number too, and that is the reason
6.5.2 measures at five rates and averages rather than trusting one. The drift
over a test range is small, and it is not zero.

Equation (12) is the part worth reading twice. Measuring static pressures on
both sides is not enough when the two sides are different sizes, because an
object that widens the duct converts velocity head back into static pressure
and a static difference alone would credit it with a recovery that is only
bookkeeping. The bracket $1 - (S_1/S_2)^2$ puts it back, and the NOTE to
Equation (14) says what usually happens to it: as a rule $S_1 = S_2$, and it
vanishes. Where it does not, it is not small:

```python
widening = noise_control.total_pressure_loss(45.0, p_d1, 0.0962, 2 * 0.0962)
print(round(noise_control.pressure_loss_coefficient(widening, p_d1), 3))
#                                 # 1.448, from the same 45 Pa of static loss
```

## 10. The substitution trick, again

The fundamental method of 6.5.2.2 measures the coefficient the way the
acoustic half measures insertion loss: run the rig with the test object, run
it again with the substitution duct, and the difference belongs to the object.
The computational route of 6.5.2.2.3 does the subtraction on the coefficients
rather than on the pressures, which means the two series need share neither
their flow rates nor even their number of points:

```python
import numpy as np

heads = np.array([20.0, 40.0, 60.0, 80.0, 100.0])   # Pa, five airflow rates
with_object = 2.5 * heads
without = 0.6 * heads

zeta = noise_control.average_pressure_loss_coefficient(
    with_object, heads, without, heads,
)
print(round(zeta, 3))             # 1.9
```

Five rates per series at least, spread evenly over the range (6.5.2.2.1).
The simplified method of 6.5.2.1, which measures the object alone, adds that
the lowest flow rate has to produce a pressure difference greater than 10 Pa,
so that the smallest number in the average is still a measurement rather than
the resolution of the manometer. The library says so on both counts: `average_pressure_loss_coefficient` warns below five points,
and `pressure_loss_coefficient` warns on a loss of 10 Pa or less, the
boundary included, because the clause reads *greater than*. The rig is drawn
below, with the rules of each method beside it.

![Two stacked runs on one duct axis, with the flow from left to right. In the upper run, series one, a fan feeds a flow meter and then a straight upstream duct, dimensioned as straight for five equivalent diameters or two metres, whichever is greater; a dashed plane 1 with pressure taps crosses that duct 1.5 equivalent diameters ahead of the test object, a silencer drawn with its baffles; and a dashed plane 2 crosses the downstream duct more than six baffle thicknesses past it. A manometer joins the two planes and reads the static pressure difference between them. The lower run, series two, is the same rig with the substitution duct in place of the object, on the same planes and the same manometer. Below, a square section of the duct at plane 1 shows a tap at the centre of each side joined by a ring, the two perpendicular survey axes, and a dashed margin by the walls. Beside it, the rules: four taps joined in a piezometric ring at plane 1; a velocity survey there at ten equally spaced positions along a pair of perpendicular axes, within plus or minus 10 % of the mean, leaving out the 15 mm by the walls; plane 2 more than six baffle thicknesses past the object, or the pressure of the reverberation room the duct opens into; for the fundamental method, both series at five flow rates or more each, spread evenly, and the loss coefficient from Equations 15 to 17 at a flow rate in the middle of the range; for the simplified method, five flow rates, the lowest giving a pressure difference above 10 Pa, and the flow rate corrected by Equations 9 and 10 when the density ratio is outside 0.98 to 1.02. A box at the foot, headed as the equations of the simplified method, carries Equation 11, the total pressure as the static pressure plus the dynamic pressure, Equation 12, the total pressure loss as the static difference plus the inlet dynamic pressure times one minus the squared area ratio, and Equation 14, the loss coefficient as the total loss over the inlet dynamic pressure. A second box below it, headed as the equations of the fundamental method at a flow rate q sub V n in the middle of the range, carries Equation 15, the total pressure loss at that flow rate as the difference of the static pressures of series one and series two at plane 1, Equation 16, the inlet velocity pressure as half the density times the square of the flow rate over the upstream duct area, and Equation 17, the loss coefficient as the one over the other; the running index n is set in italics in each.](https://docs.jmrp.io/phonometry/media/diagram_silencer_pressure_loss.svg)

*The rig of Figure 6 with the numbers of 6.5 on it. Everything upstream of the
object exists to hand it a settled, uniform flow; the two planes are where the
loss is read.*

What the flow has to be before any of that counts is a matter of geometry.
The upstream duct is straight for five equivalent diameters or two metres,
whichever is greater, so that the velocity profile has settled; it must be
uniform to ±10 % of the mean over the section, excluding the 15 mm nearest the
walls, surveyed ten points along each of two perpendicular axes about
$1.5\,d_\mathrm{e}$ upstream. The two length rules cross at a 0.4 m equivalent
diameter:

```python
print(round(noise_control.upstream_straight_length(0.0962), 2))   # 2.0 m
print(round(noise_control.upstream_straight_length(0.5), 2))      # 3.99 m
```

The static pressure of plane 1 is taken in that same section, 1.5 equivalent
diameters ahead of the object, through four taps joined in a piezometric ring:
one at the centre of each side of a rectangular duct, or equally spaced round
a circular one. It is read against a pressure downstream of the object, either
in the test duct, where the key of Figure 6 puts the taps more than six baffle
thicknesses past the object, or in the reverberation room the duct opens into.
The air temperature is measured at the flow meter and two equivalent diameters
ahead of the object, and may not drift by more than 3 K during the test.

## 11. The third standard, and the formula it shares

ISO 5135:1999 measures something else again: the sound power an air-terminal
device, air-terminal unit, damper or valve radiates, determined in a
reverberation room to ISO 3741. What a designer needs is not that but what
the device puts into the duct behind it, and Equation (1) is the step between
them:

$$
L_{W\mathrm{duct}} = L_W + \Delta L_\mathrm{r}
$$

The correction $\Delta L_\mathrm{r}$ is Equation (2) of ISO 5135, and it is
worth writing both printings side by side:

$$
\Delta L_\mathrm{r} = 10\lg\left[1 +
   \left(\frac{c}{4\pi f}\right)^{2}\frac{\Omega}{S}\right]
\qquad
D_\mathrm{td} = 10\lg\left[1 +
   \frac{\Omega}{\left(\dfrac{4\pi f\sqrt{S}}{c}\right)^{2}}\right]
$$

Expand either and both become $10\lg[1 + \Omega c^2 / (16\pi^2 f^2 S)]$.
They are one formula, their two solid-angle tables agree entry for entry, and
`open_end_transmission_loss` is both. That is why nothing new appears here for
the correction itself:

```python
d_lr = noise_control.open_end_transmission_loss(bands, area)
lw_room = np.array([58.0, 60.0, 61.0, 59.0, 55.0, 50.0])
print(noise_control.duct_sound_power_level(lw_room, d_lr).round(2))
#                                 # [69.23 66.14 63.5  59.77 55.21 50.05] dB
```

A device measured in a room is understated in the duct by eleven decibels at
the bottom of the range and by nothing at the top. The NOTE to Table 1 offers
a way round the correction rather than a second formula for it: fit a
transmission element to ISO 7235 and no correction is applied at all.

## 12. Reading a level at a duty nobody measured

A device is not tested at the one operating point a designer will use it at.
ISO 5135 5.5.2 fits a straight line by least squares through the levels
against $\lg q_V$ when the tests were made at a constant pressure loss
coefficient, or against $\lg \Delta p_\mathrm{t}$ when they were made at a
constant flow rate. The same fit serves the band levels and the A-weighted
one:

```python
duty = np.array([0.05, 0.1, 0.2, 0.4, 0.8])          # m3/s
levels = np.array([38.0, 44.5, 50.0, 56.5, 62.0])    # dB(A)

line = noise_control.fit_operating_line(duty, levels)
print(round(line.slope, 2))               # 19.93 dB per decade
print(round(line.max_deviation, 2))   # 0.3 dB
print(round(line.level_at(0.3), 1))       # 53.7 dB(A)
```

Two rules keep that honest, and the library says so on both rather than
refusing: a fit that is not a straight line is still a fit, and a level read
past the range is still a number, and what the standard asks is that a report
be honest about them. The measured points have to sit within 3 dB of the line,
because past that the levels are not a straight line in this variable and
reading the line off means nothing. And the line may be extended down to half
the smallest duty measured and up to twice the largest, and no further, which
for these five points is 0.025 to 1.6 m³/s. Either one out of range raises a
`SilencerMeasurementWarning`:

```python
print(line.valid_range)           # (0.025, 1.6)
```

Clause 8 k) closes the loop: a report gives the fully corrected levels to the
nearest half decibel and has to state which of them were extrapolated rather
than measured directly. `.plot()` draws that distinction, shading the two ends
of the range that are extrapolation.

## What this guide covers

- **Covered.** The arithmetic of the substitution measurement: Equation (1) of both
  standards through `substitution_insertion_loss`, with the reverberation-time
  correction of ISO 7235 6.3; the octave fold of ISO 11691 Equation (2) through
  `octave_insertion_loss`; ISO 7235 Table 6 and the three-or-five rule of 6.2.1
  through `microphone_spread_limit` and `microphone_positions_required`; the
  reproducibility of ISO 11691 Table 1 and of all three columns of ISO 7235
  Table 7, with the expanded uncertainty of 7.9; and the scope ISO 11691 draws
  in 1.1 and 4.5, including the area-ratio check that warns outside it. The
  open end of the duct: Equations (B.3) and (B.4) through
  `open_end_transmission_loss` and `open_end_reflection_coefficient`, with the
  five solid angles of Table B.1; the transmission loss of Equation (6) and the
  flow-noise sound power of Equation (7); and the cut-on frequencies of
  Equations (4) and (5) that the modal-filter requirement of 5.2.2.3 steps at.
  And the flow half of 6.5: the gas law of Equations (10), (21) and (22), the
  volume flow rate of (8) and (9), the velocity head of (13), (16), (19) and
  (20), the total pressure of (11), the area-change correction of (12), the
  pressure loss coefficient of (14) and (17), the substitution average of (18),
  and the settling length of 6.5.2.2.1. From ISO 5135: the duct sound power
  level of Equation (1); Equation (2), which is Equation (B.3) of ISO 7235
  written out again and is served by the same function; and the least-squares
  operating line of 5.5.2 through `fit_operating_line`, with the 3 dB limit on
  the fit, the half-to-twice range it may be read over, and a `.plot()` that
  shades the part of that range which is extrapolation.

- **Not covered.** Nothing here builds a test facility or checks one: the modal-filter
  attenuation, the anechoic termination's reflection coefficient, the
  substitution duct's dimensional tolerance and the limiting insertion loss are
  described but not computed, and Equation (7) is given the room correction
  rather than deriving it. The flow measurement itself is not modelled: the
  differential-pressure devices of ISO 5167-1, the velocity survey and the
  piezometric ring are procedure rather than arithmetic. Nothing here builds a
  reverberation room or qualifies one: the ISO 3741 determination both
  standards hand their receiving side to is a separate page, and the background
  corrections, the discrete-tone check and the room qualification belong to it.
  ISO 11820, which measures a silencer in situ where the substitution trick is
  usually impossible, is not computed here either: it has
  [a page of its own](https://docs.jmrp.io/phonometry/devices/noise-control/in-situ-noise-control/).

## See also

- [Silencers](https://docs.jmrp.io/phonometry/devices/noise-control/silencers/): the reactive
  four-pole models this measurement is the counterpart of, and the rig it is
  made on, described in full.
- [Duct-Borne Noise: Fan to Room](https://docs.jmrp.io/phonometry/devices/noise-control/duct-path/):
  where a measured insertion loss goes once it has been bought.
- [HVAC Noise the German Way (VDI 2081)](https://docs.jmrp.io/phonometry/devices/noise-control/vdi2081-air-systems/):
  the splitter-silencer insertion loss predicted from geometry, for comparison
  with what a laboratory would measure.
- [Industrial noise control](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/):
  the rival closed form for the end reflection, and the air-terminal
  corrections a diffuser is selected with.
- [Errata in published sources](https://docs.jmrp.io/phonometry/reference/errata/): the gap Table 6
  of ISO 7235 leaves at 160 Hz, and the two printed gas-law constants.
- API reference:
  [`noise_control.silencer_measurement`](https://docs.jmrp.io/phonometry/reference/api/noise_control/silencer-measurement/).

## References

- **International Organization for Standardization. (1995).** *Acoustics — Measurement of insertion loss of ducted silencers without flow — Laboratory survey method* (ISO 11691:1995).
  The survey-grade sibling: its Equations (1) and (2), Table 1, and the scope it draws in 1.1 and 4.5. Read from BS EN ISO 11691:2009, which endorses it without modification.
- **International Organization for Standardization. (1997).** [*Acoustics – Determination of sound power levels of noise from air-terminal devices, air-terminal units, dampers and valves by measurement in a reverberation room*](https://www.iso.org/standard/22490.html) (ISO 5135:1997).
  The sound power of an air-terminal device in a reverberation room: Equation (1), the end reflection loss of Equation (2) with the solid angles of Table 1, and the straight-line fit of 5.5.2. Read from BS EN ISO 5135:1999, which is identical with it and dates this guide's citations of it.
- **International Organization for Standardization. (2003).** [*Acoustics — Laboratory measurement procedures for ducted silencers and air-terminal units — Insertion loss, flow noise and total pressure loss*](https://www.iso.org/standard/30385.html) (ISO 7235:2003).
  The measurement itself: Equation (1), the reverberation correction of 6.3, Table 6 and the rule of 6.2.1, and Table 7 with the coverage factor of 7.9. Read from BS EN ISO 7235:2009, which endorses it without modification.
- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for reverberation test rooms*](https://www.iso.org/standard/52053.html) (ISO 3741:2010).
  The sound power determination both standards hand the receiving side to, and the source of the reverberation times the correction of 6.3 needs.