# Silencers, Screens and Barriers In Situ

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/noise-control/in-situ-noise-control/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/noise-control/in-situ-noise-control/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-15
Updated: 2026-11-16T21:36:14Z
Standards: ISO 11820:1996; ISO 11821:1997; ISO 10847:1997
Verified: 50 conformance checks (ISO 11820:1996; ISO 11821:1997; ISO 10847:1997) https://docs.jmrp.io/phonometry/reference/conformance/#in-situ-measurement-of-silencers-screens-and-barriers
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Silencers (ISO 11820), removable screens (ISO 11821) and barriers (ISO 10847) measured in situ, and why their background corrections are never merged.

---

A laboratory measurement of a noise control device answers one question: what is
this product worth, under conditions chosen so that two products can be
compared. It is the right question when there is a catalogue to write. It is the
wrong one when the silencer is already welded into the duct, the screen has been
standing between the press and the bench for a year, and the barrier was built
before anyone thought of measuring it.

These three standards ask the other question. Each of them measures a device
**where it already stands**, in the installation it belongs to, with whatever is
around it.

![Three panels. Left: the decibels each of three standards removes from a measured level against the margin over the background, drawn as two staircases and one curve; the ISO 11820 table falls from three decibels at a margin of three to half a decibel at nine and ten, the ISO 10847 table from two decibels at four to one decibel from six to nine, and the ISO 11821 energy subtraction runs smoothly from about one and a quarter decibels at six down towards zero, with the regions under each table's own threshold shaded to mark the refusals. Middle: the four microphone distances a screen measurement uses against the screen height, four straight rays for a quarter, a half, once and twice the height, with the quarter-height ray flattened onto the one-metre floor below four metres and the half-height one below two, the band where either is held out shaded. Right: the height of the reference microphone of a barrier measurement against the distance from the near end of the source to the barrier, a curve that dips to five point seven metres near five metres and rises to seven at fifteen, where it drops back to the flat one point five metres above the four-metre top edge that holds at any greater distance](https://docs.jmrp.io/phonometry/media/in_situ_noise_control.svg)

*Three standards, three answers to the same question about background noise; the
microphone positions a screen measurement uses; and the one microphone whose
whole job is to hear the source rather than the device.*

## 1. What in situ costs, and what it buys

The laboratory buys two things: a controlled environment, and a **substitution**
measurement. ISO 7235 measures a duct silencer by running a source into a test
duct with the silencer in place, then with a straight replacement section of the
same length, so that the two runs differ by the silencer alone.

In situ neither is available. The environment is whatever room, duct or open
space the device sits in, and there is no replacement section to swap in. What
is left is the pair of levels the installation allows, and the arithmetic that
turns them into a quantity: the ratio of the two measurement areas, and the
difference of the two field corrections.

$$
D_\mathrm{ts} = D_{\mathrm{t}p\mathrm{s}} + 10 \lg \frac{S_2}{S_1} + K_2 - K_1
$$

That is Equation (19) of ISO 11820, and it is the whole idea of measuring in
situ. The level difference is what a meter reads. The area term converts each
side's mean level into the sound power it stands for, because the source side
may be a duct cross-section while the receiver side is a room. The field
corrections carry whatever the two sides do not share.

```python
from phonometry import noise_control

bands = [125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0]
source = [98.0, 99.0, 97.0, 95.0, 92.0, 88.0]     # dB, in the duct
receiver = [72.0, 68.0, 60.0, 54.0, 50.0, 49.0]   # dB, in the room it feeds

res = noise_control.in_situ_transmission_loss(
    source, receiver,
    source_area_m2=0.9,      # the duct cross-section
    receiver_area_m2=10.8,   # a quarter of the room absorption at 500 Hz
    frequencies=bands, case=2,
)
print(res.loss.round(1))        # [15.2 20.2 26.2 30.2 31.2 28.2] dB
print(res.area_term_db.round(1))   # [-10.8 -10.8 -10.8 -10.8 -10.8 -10.8] dB
```

The area term is negative here and that is not a mistake. A duct of 0.9 m²
discharging into a room whose quarter-absorption is 10.8 m² spreads the same
power over twelve times the area, so the room is already quieter than the duct
before the silencer does anything. Subtracting that is what stops the room being
credited to the silencer. The term comes back once per band even here, where
both areas were typed as single numbers, because the area of a room is not one
number: the next section shows why.

## 2. The twenty installations

![Section through a duct run: the machine, the duct, the silencer with its splitters, and the room the duct discharges into. A dashed plane upstream of the silencer marks the source-side measurement surface, the duct cross-section, with three microphone positions across it; a second dashed plane downstream marks the receiver-side surface, a quarter of the room absorption, with three microphone positions in the room. The upstream distance is one and a half equivalent diameters and the downstream one is twelve times the root of the downstream area less ten times the root of the free area. A box at the foot carries the transmission loss as the level difference plus the ratio of the two areas plus the difference of the two field corrections](https://docs.jmrp.io/phonometry/media/diagram_silencer_in_situ.svg)

A silencer sits between two of four things: a duct, a room with a diffuse field,
a room without one, and open space. Sixteen pairs of those are transmission
measurements and four more are insertion measurements, and Figure 1 draws all
twenty. The area rule for each side follows from what that side is, and clause 9
states it.

```python
case = noise_control.installation_case(2)
print(case.source_side, case.receiver_side)   # duct diffuse_room
print(case.quantity)                          # transmission
print(case.receiver_area_rule)
# one-quarter of the absorption of the receiver room
```

Naming the case is not decoration. `in_situ_transmission_loss` refuses a case
that belongs to the insertion set and `in_situ_insertion_loss` refuses the
opposite, because Equations (19) and (21) are two quantities and Figure 1 is
what says which one an installation can give.

The room area itself comes from the reverberation time, through Equations (6),
(10) and (12), which are the same expression written three times:

```python
area = noise_control.reverberant_surface_area_m2(
    320.0, [1.6, 1.4, 1.2, 1.1, 1.0, 0.9],
)
print(area.round(1))   # [ 8.1  9.3 10.8 11.8 13.  14.4] m^2
```

It is a quarter of the Sabine equivalent absorption area, which is the factor
that turns a reverberant level into a sound power. A reverberation time is a
band quantity, so the area is one too, and the 10.8 m² of section 1 was only its
value at 500 Hz. Both loss functions take each area, and the field correction,
as one value for every band or as one value per band, so the array goes in as it
comes out:

```python
res = noise_control.in_situ_transmission_loss(
    source, receiver,
    source_area_m2=0.9, receiver_area_m2=area,
    frequencies=bands, case=2,
)
print(res.area_term_db.round(1))   # [ -9.6 -10.1 -10.8 -11.2 -11.6 -12.1] dB
print(res.loss.round(1))        # [16.4 20.9 26.2 29.8 30.4 26.9] dB
```

At 500 Hz nothing moves. Below it the room is more reverberant, its area smaller
and the silencer credited with more, by 1.2 dB at 125 Hz; above it the other way
round, by 1.3 dB at 4 kHz. The duct cross-section stays one number, because it
is one.

## 3. The silencer that is quiet and blocks the duct

A silencer has not been measured until the flow has been measured too. ISO 11820
devotes clause 9 to it, and the library carries the whole chain: the total
pressure loss of Equation (13), the static difference behind a change of area of
Equation (14), the velocity pressure and the velocity it stands for, the gas
density of Equation (29), and the velocity inside the silencer of Equation (31),
which is the one the regenerated noise answers to.

```python
print(round(noise_control.gas_density_kg_m3(temperature_c=120.0), 3))   # 0.887
print(round(noise_control.silencer_flow_velocity_m_s(
    8.0, upstream_area=0.9, free_area_m2=0.45), 1))                  # 16.0
```

The measurement surfaces have their own geometry. Upstream, one and a half
equivalent diameters of the measurement cross-section; downstream,
$12\sqrt{S_\mathrm{d}} - 10\sqrt{S_\mathrm{f}}$, which for a silencer whose free area is most of
the duct can fall to zero or below. The standard has its own escape for that, which is
agreement between the parties, and the case is reported rather than returned as
a distance nobody can stand at.

### How the measurement goes

Choose the installation from Figure 1 and read off which area rule each side
takes. Place the source-side surface one and a half equivalent diameters
upstream of the silencer and the receiver-side surface at the distance Equation
(16) gives, or agree on one when that expression falls to zero. Run the machine,
measure the mean level on each surface, and measure the extraneous sound with
the switchable sources off if you can, because the energy route of Equations
(17) and (18) is better than the stepped table and both refuse under 3 dB
anyway. Record the temperature on both sides: where they differ, the field
correction of Equations (20) and (22) is not zero. Both equations print the
ratio of the two absolute temperatures the wrong way up: the correction turns a
squared pressure into a sound power, so the hotter side takes the larger one,
and the print gives the reciprocal. `temperature_field_correction` returns the
equations as printed, so that its number is the one the standard gives, and
[the errata registry](https://docs.jmrp.io/phonometry/reference/errata/) records the evidence and
the reading the characteristic impedance asks for. Then measure the flow, the
total pressure loss across the silencer and the flow velocities in the duct.
The two conditions of 9.2 are lines for the report, not for the measurement:
where the velocities close to the entrance of the silencer deviate from the
mean flow velocity by more than 10 %, or where the flow velocity measurements
of 8.3.3 show a comparably non-uniform distribution, report the actual
distribution, since such a flow may raise the pressure loss and the
regenerated sound.

## 4. The screen you can take away

![Section through a workshop: the machine on the left, the screen standing on the floor, and four microphones behind it at a quarter, a half, once and twice the screen height, the nearest one held out to the one-metre floor. An operator stands at the third position, and the microphone height is the operator height of one metre fifty-five plus or minus seven and a half centimetres. A box at the foot carries the attenuation as the difference between the run without the screen and the run with it](https://docs.jmrp.io/phonometry/media/diagram_screen_in_situ.svg)

ISO 11821 has the one thing the other two lack: the device can be removed for a
run. A removable screen is wheeled aside, the room is measured, the screen is
wheeled back, and the difference is the attenuation.

```python
res = noise_control.screen_attenuation(
    [78.0, 80.0, 81.0, 79.0, 76.0, 72.0],   # dB, screen away
    [74.0, 74.0, 72.0, 68.0, 63.0, 58.0],   # dB, screen in place
    frequencies=bands,
    a_weighted_unscreened_level=84.1,
    a_weighted_screened_level=74.6,
)
print(res.attenuation)             # [ 4.  6.  9. 11. 13. 14.] dB
print(res.a_weighted_attenuation)  # 9.5 dB
print(res.rounded)                 # [ 4  6  9 11 13 14] dB
print(res.rounded_a_weighted)      # 10 dB
```

7.4 c) reports both to the nearest whole decibel. `rounded` and
`rounded_a_weighted` give them that way, as integers, while `attenuation`
keeps the unrounded difference to compute with. An exact half goes to the even
decibel, as in the other in-situ results of the library, so the 9.5 dB above is
reported as 10 dB.

The A-weighted pair is clause 5.9, and it comes with a condition the library
enforces rather than mentions: it may not be obtained with an artificial source.
An A-weighted number weights a spectrum, and with a loudspeaker standing in for
the machine the spectrum weighted is the loudspeaker's. Asking for one anyway
raises `ValueError` rather than returning a number that would be reported as the
machine's.

An artificial source has a test of its own to pass first. Definition 3.10 reads
the directivity index at twelve positions evenly spaced on a horizontal circle
of about 1.5 m radius, as the logarithmic mean less the position, and 5.2.2
accepts the source while no position falls more than 8 dB below the mean.

Where the microphones stand is 5.5.2: a quarter, a half, once and twice the
screen height, never closer than 1 m. Under 4 m the quarter-height position
falls inside that floor and is pushed out to it, and at 2 m and under the
half-height one is pushed out too, so the two nearest positions coincide and
the measurement is made at three distances. That is the printed rule rather
than an oversight.

```python
print(noise_control.microphone_distances_m(3.0))   # [1.  1.5 3.  6. ] m
```

NOTE 2 says what the spread of those four answers means: the smallest
attenuation is found at the most remote position and the largest at the nearest,
which is why the standard asks for all four rather than for an average.

### How the measurement goes

Put the microphones on the line perpendicular to the screen, at a quarter, a
half, once and twice its height, and push the ones that fall inside 1 m out to
1 m. Set each of them at the operator height where the workplace does not fix
one. Run the machine with the screen in place, take the levels, wheel the screen
away without touching anything else, and take them again. Measure the background
with the machine off at the same positions: over 10 dB of margin needs no
correction, between 6 dB and 10 dB takes the boxed formula of 5.7, and under
6 dB the conditions are not acceptable and the answer is to come back on a
quieter day. For an impulsive source, at least three repeats with the S time
weighting, and the arithmetic mean of them.

## 5. The barrier that was built years ago

![Two sections of the same site. The upper one is the campaign before the barrier, with the source region on the left, a reference microphone standing where the top edge will be and a receiver microphone at one metre twenty or more; the lower one is the campaign after, with the barrier built, the reference microphone one and a half metres above its top edge, and the diffracted path curving over the top to the receiver. A box at the foot carries the insertion loss as the change at the reference less the change at the receiver, and the weather the two campaigns have to share](https://docs.jmrp.io/phonometry/media/diagram_barrier_in_situ.svg)

An outdoor barrier cannot be removed and usually cannot be measured before it
exists. ISO 10847 offers two ways out, and is honest about what each is worth.

The **direct method** needs the site before the barrier was built. Both
campaigns use the same receiver positions and the same reference microphone, and
the reference term normalises the source: whatever ran differently on the second
day, the reference microphone heard it too.

$$
D_\mathrm{IL} = \left(L_{\mathrm{ref},\mathrm{A}} - L_{\mathrm{ref},\mathrm{B}}\right)
       - \left(L_{\mathrm{r},\mathrm{A}} - L_{\mathrm{r},\mathrm{B}}\right)
$$

```python
from phonometry import environment

res = environment.measured_insertion_loss_direct(
    [76.0, 74.0, 71.0, 67.0, 62.0, 56.0],   # reference, before
    [78.0, 76.0, 73.0, 69.0, 64.0, 58.0],   # reference, after
    [63.0, 61.0, 58.0, 54.0, 49.0, 43.0],   # receiver, before
    [58.0, 53.0, 47.0, 41.0, 35.0, 29.0],   # receiver, after
    frequencies=bands,
)
print(res.insertion_loss)   # [ 7. 10. 13. 15. 16. 16.] dB
```

The source was 2 dB louder on the second day in every band, and the answer does
not contain those 2 dB. That invariance is the reason the reference microphone
exists.

The **indirect method** borrows the "before" campaign from a substitute site
judged equivalent in terrain, ground and source, which makes it an estimate and
the standard says so. Each campaign carries a correction for the kind of
receiver position, 0 dB in a hemi free field and 6 dB against a facade where the
pressure doubles. Clause 8.2.2 prints the second correction with a prime, the
same prime its equations give the "after" campaign, so read literally it would
tie each campaign to one kind of position; the NOTE that closes the clause asks
for positions where the two corrections are essentially the same, which only
makes sense if each campaign takes its own. `measured_insertion_loss_indirect` takes a
receiver type for each campaign, and
[the errata registry](https://docs.jmrp.io/phonometry/reference/errata/) gives the reading.

The reference microphone stands at least 1.5 m above the top edge of the
barrier, measured from its highest point where the top is not a straight edge,
and 7.2.2 says so with "shall". Where the near end of the source region is
closer than 15 m, the NOTE to 7.2.2 lets the microphone be raised further, until
it looks over the top edge by 10 degrees. The NOTE only ever raises it, so the
height is the higher of the two. A 4 m barrier 8 m from the source takes the
angle; a 3 m barrier 5 m from the source reaches its 10 degrees at 4.34 m and
keeps the 4.5 m of the clearance:

```python
print(round(environment.reference_microphone_height_m(
    4.0, source_to_barrier_m=8.0), 2))            # 5.93 m
print(environment.reference_microphone_height_m(
    3.0, source_to_barrier_m=5.0))                # 4.5 m
print(environment.reference_microphone_height_m(4.0))   # 5.5 m
```

Where the top of the barrier already stands 80 degrees or more above the near
end of the source region, no height reaches the 10 degrees at all. The
microphone then keeps the clearance, and a `BarrierInSituWarning` says the NOTE
could not be followed.

## 6. The weather is part of the measurement

Two campaigns separated by months are two different days of weather, and clause
6 spends most of its length on that. The wind enters as the vector component of
the average velocity on the line from the source to the receiver, positive
downwind. Table 1 gives a downwind class and a calm one over any distance, and
adds an upwind class over short distances alone. That upwind row is printed
"+ 1 to − 5", an interval whose ends run the wrong way and whose lower end is
where the downwind class begins; `wind_class` reads it as −5 m/s to −1 m/s, the
mirror of the downwind row, and
[the errata registry](https://docs.jmrp.io/phonometry/reference/errata/) gives the evidence.

```python
print(environment.wind_class(2.5))                        # downwind
print(environment.wind_class(-2.0, short_distance=True))  # upwind
print(environment.wind_class(-2.0))                       # None
```

Whether the geometry is a short distance is not a matter of opinion either. 6.3.1
prints one inequality for the "before" campaign and two for the "after" one, all
against the same ratio of 0.1, and the two campaigns can disagree:

```python
geometry = environment.check_short_distance(
    source_height_m=1.0, receiver_height_m=1.5, barrier_height_m=4.0,
    source_to_barrier_m=10.0, barrier_to_receiver_m=20.0,
)
print(geometry.before, geometry.after)   # False True
```

Above 5 m/s in absolute value no measurement is made at all, which is a refusal
rather than a class. The two campaigns must also agree within 2 m/s on the
component and within 10 °C on the temperature, and the cloud cover is recorded
in the four classes of Table 2, because the temperature gradient that bends a
ray outdoors is not measured directly and the sky is the best proxy available.

### How the measurement goes

Fix the receiver positions and the reference position first, and keep them for
both campaigns: the subtraction means nothing otherwise. Put the reference
microphone at least 1.5 m above the top edge of the barrier, on a vertical plane
through it, measured from the highest point where the top is not a straight
edge, and higher where the source region comes closer than 15 m and the
elevation rule of the NOTE asks for more. Record the wind component on the source-to-receiver line, the
temperature and the cloud cover for every run, and stop when the wind passes
5 m/s. Repeat at least three times. When the second campaign comes, check that
the weather still matches within 2 m/s and 10 °C before anything else, because
nothing downstream can repair a mismatch there.

## 7. One correction, three standards, three answers

All three documents face the same problem: the measured level contains sound
that did not come from the source. All three answer it differently, and the
differences are not rounding.

**ISO 11820** prints a stepped table, positive, to be **subtracted**: 3 dB at a
margin of 3 dB, falling to 0.5 dB at 9 and 10, nothing above, and under 3 dB the
measurements are invalid. **ISO 10847** prints a stepped table, negative, to be
**added**: 2 dB at a margin of 4 or 5, 1 dB from 6 to 9, nothing from 10 up, and
under 4 dB the results are not valid. **ISO 11821** prints no table at all and
boxes the energy subtraction, correcting only inside a window from 6 dB to 10 dB
and refusing anything narrower, because the background it names includes
wind-generated noise and the remedy for that is a quieter day.

```python
print(noise_control.silencer_background_correction([9.0]))   # [0.5] dB off
print(environment.barrier_background_correction([9.0]))      # [-1.] dB added
print(round(80.0 - noise_control.screen_background_corrected_level(
    [80.0], [71.0])[0], 2))                                     # 0.58 dB off
```

Three standards, one margin of 9 dB, three answers: 0.5 dB, 1 dB and 0.58 dB.
They are kept as three implementations for that reason, and a conformance check
holds them against each other at the margin where they part. The two tables and
their opposite signs are recorded in the errata registry as a difference that is
**not** an erratum, so that nobody merges them into one helper.

ISO 11820 offers a second route around extraneous sound, for the case where the
sources it works on can be switched off and measured on their own: the energy
subtraction of Equations (17) and (18), capped at 3 dB. Past the cap the quantity
is not determined, and what may be stated instead is the inequality of clause 4.
`extraneous_corrected_mean_level` returns the corrected level, the margin it was
read at and whether the correction went past the cap (`capped`), so that a capped number
cannot be written down as a determination. The cap is judged on the margin, where Table 1 draws it. At a
margin of exactly 3 dB the subtraction takes off 3.02 dB, which is the printed
3 dB unrounded and the correction Table 1 applies at that row, so the level is
still determined; under 3 dB it is not.

## What this guide covers

- **Covered.** **ISO 11820:1996** in full arithmetic: the level differences of Equations (1),
  (2) and (3); the sound power of Equations (5), (7), (9) and (11) with the
  reverberant area of Equations (6), (10) and (12); the transmission loss of
  Equation (19) and the insertion loss of Equation (21), with areas and field
  corrections one value or one per band, and the temperature field correction of
  Equations (20) and (22); the twenty installations of Figure 1 with
  the area rules of clause 9; the background table of clause 4 and the extraneous
  energy subtraction of Equations (17) and (18) with its 3 dB cap, judged on the
  margin; the octave fold
  of 9.1.5; the measurement distances of Equations (15) and (16); and the flow
  quantities of Equations (13), (14) and (27) to (31).

  **ISO 11821:1997**: the attenuation of 5.8 and the A-weighted attenuation of
  5.9, refused with an artificial source; the boxed background correction of 5.7
  with its own window; the directivity index of definition 3.10 and the acceptance
  limit of 5.2.2; the microphone geometry of 5.5.2 with its floor; the repeat rule
  of 5.6.2.1 for an impulsive source; the whole-decibel reporting of 7.4 c); and
  the printed thresholds of the operator
  sphere, the outdoor range and the standard deviation of reproducibility.

  **ISO 10847:1997**: the direct method of 8.2.1 and the indirect method of 8.2.2
  with its two receiver corrections; the background table of 6.4; the wind classes
  of Table 1 and the cloud cover classes of Table 2; the short-distance test of
  6.3.1; the reference microphone height of 7.2.2, raised where the elevation rule
  of its NOTE asks for more; the hemi-free-field clearance of 8.1.2; and the equivalent-site
  geometry of 6.1. One defect in the print of ISO 11820 and two in that of
  ISO 10847 are recorded in the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/),
  along with a note that the two stepped background tables are a difference and
  not an erratum.

- **Not covered.** Nothing here predicts. The insertion loss a barrier is designed to give and the
  attenuation a silencer is selected for are computed elsewhere, from geometry and
  from catalogue data; this page starts from levels that were measured on site.
  Nothing here qualifies an instrument or a test environment: the sound level
  meter classes, the windscreen, the calibration intervals and the microphone
  mounting are procedure. The equivalence of a substitute site is a judgement the
  standard asks two parties to make, and the radius and the sector it states are
  carried here as the numbers they are rather than as a test a program can run.
  The report templates are prose. No worked numeric example is printed in any of
  the three documents, so nothing here reproduces one.

## See also

- [Enclosures and cabins measured](https://docs.jmrp.io/phonometry/devices/noise-control/enclosure-cabin-insulation/):
  the same in-situ habit of mind applied to a box around a machine and a cabin
  around an operator.
- [Measuring a silencer](https://docs.jmrp.io/phonometry/devices/noise-control/silencer-measurement/):
  the laboratory method of ISO 7235, with the test duct and the substitution run
  that ISO 11820 does without.
- [Industrial noise control](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/):
  the predicted insertion loss of a screen or an enclosure, which is the quantity
  these standards measure rather than compute.
- [Outdoor sound propagation](https://docs.jmrp.io/phonometry/environment/propagation/outdoor-propagation/):
  the ISO 9613-2 barrier attenuation term a prediction computes for the barrier
  ISO 10847 measures.
- [Sound power in situ by comparison](https://docs.jmrp.io/phonometry/devices/emission/sound-power-in-situ/):
  the other way of determining a quantity in a room that was never built for it.
- [Errata in published sources](https://docs.jmrp.io/phonometry/reference/errata/): a temperature
  ratio of ISO 11820 Equations (20) and (22) printed the wrong way up, an upwind
  wind class printed with a positive lower bound, and one prime asked to mean two
  different things.
- API reference:
  [`noise_control.silencer_in_situ`](https://docs.jmrp.io/phonometry/reference/api/noise_control/silencer-in-situ/),
  [`noise_control.screen_in_situ`](https://docs.jmrp.io/phonometry/reference/api/noise_control/screen-in-situ/)
  and [`environment.propagation.barrier_in_situ`](https://docs.jmrp.io/phonometry/reference/api/environment/barrier-in-situ/).

## References

- **European Committee for Standardization. (2015).** *Railway applications – Track – Noise barriers and related devices acting on airborne sound propagation – Test method for determining the acoustic performance – Part 7: Extrinsic characteristics – In situ values of insertion loss* (CEN/TS 16272-7:2015).
  The railway counterpart of ISO 10847, which reprints its background table and wind classes: Table 4 and 7.3.7, the background correction and its smallest margin, are held against the barrier measured in situ.
- **International Organization for Standardization. (1995).** [*Acoustics – Measurement of sound insulation in buildings and of building elements – Part 3: Laboratory measurements of airborne sound insulation of building elements*](https://www.iso.org/standard/3958.html) (ISO 140-3:1995).
  Clause 6.5, the background correction of 1.3 dB for a 6 dB margin that the boxed formula of ISO 11821 5.7 gives too.
- **International Organization for Standardization. (1996).** [*Acoustics — Attenuation of sound during propagation outdoors — Part 2: General method of calculation*](https://www.iso.org/standard/20649.html) (ISO 9613-2:1996).
  The barrier attenuation term a prediction computes, which ISO 10847 measures instead.
- **International Organization for Standardization. (1996).** *Acoustics — Measurements of noise from silencers in situ* (ISO 11820:1996).
  The silencer measured in the installation it was fitted to: the twenty installations of Figure 1, the transmission loss of Equation (19), the insertion loss of Equation (21), the stepped background table of clause 4 and the flow quantities of clause 9. Read from BS EN ISO 11820:1997, which endorses it without modification.
- **International Organization for Standardization. (1997).** *Acoustics — In-situ determination of insertion loss of outdoor noise barriers of all types* (ISO 10847:1997).
  The barrier already built: the direct method of 8.2.1, the indirect method of 8.2.2 with its equivalent site, the wind and weather classes of clause 6, and the reference microphone of 7.2.2.
- **International Organization for Standardization. (1997).** *Acoustics — Measurement of the in situ sound attenuation of a removable screen* (ISO 11821:1997).
  The screen that can be taken away for one of the two runs: the attenuation of 5.8 and 5.9, the boxed background formula of 5.7, the directivity test an artificial source has to pass, and the microphone geometry of 5.5.2.
- **International Organization for Standardization. (1998).** [*Acoustics – Guidelines for noise control by silencers*](https://www.iso.org/standard/23775.html) (ISO 14163:1998).
  Table B.1, the worked example of three spectra and their octave-band attenuation that ISO 11820 also prints in 9.1.5.
- **International Organization for Standardization. (2003).** [*Acoustics — Laboratory measurement procedures for ducted silencers and air-terminal units — Insertion loss, flow noise and total pressure loss*](https://www.iso.org/standard/30385.html) (ISO 7235:2003).
  The laboratory method ISO 11820 exists as the alternative to: a test duct, a known termination and a substitution measurement.
- **International Organization for Standardization. (2009).** [*Quantities and units – Part 1: General*](https://www.iso.org/standard/30669.html) (ISO 80000-1:2009).
  Annex B, B.3 Rule A, the rounding of an exact half that ISO 10847 clause 10 c) leaves open.