# Enclosures and Cabins Measured (ISO 11546, ISO 11957)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/noise-control/enclosure-cabin-insulation/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/noise-control/enclosure-cabin-insulation/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-15
Updated: 2026-11-16T21:36:14Z
Standards: ISO 11546-1:1995; ISO 11546-2:1995; ISO 11957:1996; ISO 3741:2010; ISO 717-1:2020
Verified: 39 conformance checks (ISO 11546-1:1995; ISO 11546-2:1995; ISO 11957:1996; ISO 3741:2010; ISO 717-1:2020) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Machine enclosures (ISO 11546) and operator cabins (ISO 11957) measured: two determinations, substitute sources, the room check and acceptance.

---

A model says what an enclosure should be worth. It takes the transmission loss
of the panels, subtracts a penalty for the reverberant build-up in the cavity
and returns an insertion loss. It is a good number and it is not the one a
buyer can hold anybody to, because it knows nothing about the gap under the
door, the conduit that was run through the wall afterwards, or the fan that was
fitted to keep the machine cool.

These three standards measure what was built. The quantity is a **difference of
two runs**: determine the machine's sound power without the enclosure,
determine it again with the enclosure in place, and subtract band by band.

$$
D_W = L_{W,\text{without}} - L_{W,\text{with}}
$$

That is Equation (1) of both parts of ISO 11546, and nothing else in either
document is more complicated than it. The care is all in what "the same
determination twice" means.

![Three panels. Left: two octave-band sound power spectra of the same machine, one measured without the enclosure and falling from ninety-six to eighty-nine decibels, one measured with it and falling from eighty-eight to sixty-three, with the area between them shaded and the insertion loss drawn against a second axis rising from eight decibels at 125 Hz to twenty-six at 2 kHz, annotated with the A-weighted insertion loss of nineteen point three decibels. Middle: the area ratio a room must reach against its mean absorption coefficient, on logarithmic axes, drawn as two straight falling lines, one for the two-decibel environmental correction limit of the precision and engineering methods and one for the seven-decibel limit of the survey methods, with the seven room descriptions of Table C.2 marked on the upper line. Right: a staircase of the loudspeaker positions an in-situ cabin measurement requires against the largest deviation of the apparent insulation between any two of them, flat at three up to three decibels, stepping to four, five and six, and flat at six thereafter, with the region past six decibels shaded to mark where the excess is reported instead](https://docs.jmrp.io/phonometry/media/enclosure_cabin_insulation.svg)

*The insertion loss is the gap between two runs; the room has to be good enough
for the method that measured them; and in situ the number of source positions
is decided by the answer.*

## 1. Two parts, one procedure

![Two arrangements side by side. On the left, the same machine measured twice on the same dashed measurement surface, once standing free and once inside the enclosure, and the insertion loss is the difference of the two sound powers. On the right, a room driven by a loudspeaker with three microphones in it and an empty cabin inside it with two more, and the insulation is the difference of the two sound pressure levels. A box at the foot carries both equations](https://docs.jmrp.io/phonometry/media/diagram_enclosure_cabin_measurement.svg)

**ISO 11546-1** measures in a laboratory, for a **declaration**: the
manufacturer's figure, obtained under conditions a buyer can compare across
suppliers. **ISO 11546-2** measures the same thing **in situ**, for an
**acceptance**: the enclosure as installed, in the room it was installed in,
with the machine it was built for.

The two share their definitions, their equations, their reporting rules and
their artificial source word for word. What changes is the environment, the
base standard the levels come from, and, in part 2, an annex that asks whether
the room is good enough at all.

```python
from phonometry import noise_control

bands = [125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0]
without = [96.0, 98.0, 99.0, 97.0, 94.0, 89.0]   # dB, machine alone
with_box = [88.0, 86.0, 81.0, 74.0, 68.0, 63.0]  # dB, enclosure fitted

res = noise_control.enclosure_sound_power_insulation(
    without, with_box, frequencies=bands, fraction=1,
)
print(res.rounded)                    # [ 8 12 18 23 26 26] dB
print(round(res.a_weighted_insulation, 1))   # 19.3 dB
```

The A-weighted number is $D_{W\mathrm{A}}$ of Equation (2), and it is the single figure
a declaration carries. Clause 9.4 reports every band value rounded to the
nearest decibel, which is what `.rounded` holds.

Both parts also measure a **sound pressure** insulation at a stated position,
Equations (3) and (4), through `enclosure_sound_pressure_insulation`. It is a different
quantity with the same arithmetic: it belongs to one microphone position, which
is why the standard makes the position reportable.

## 2. What the method may declare

Table 1 of both parts is the part that gets skipped, and it is the part that
decides what may be written on the data sheet. Not every way of determining a
sound power gives a spectrum: a survey-grade determination hands back an
A-weighted value and nothing per band, so $D_W$ cannot be declared from it at
all.

```python
for entry in noise_control.applicable_methods(condition="in-situ"):
    if not entry.band_values:
        print(entry.base_standard, entry.quantities)
# ISO 3746 ('D_WA',)
# ISO 11202 ('D_pA',)
```

Those two rows exist only in part 2. The laboratory table of part 1 admits no
survey-grade determination at all, and its own footnote goes further: where a
standard has a grade 3 variant, ISO 9614-1 and ISO 11204, that variant is
excluded. A declaration is the one place where the measurement has to be at
least an engineering one, and Table 1 is where the document says so.

The table also decides which substitute source is available. Where the machine
cannot be run, both parts replace it. Clause 1 draws the scope around the first
case rather than the substitutes: the part applies to a free-standing enclosure
smaller than 2 m³ without any restriction, and a larger one may still be
measured with its actual source while the base standard's own limit on volume
is met. The two substitutes are:

- the **reciprocity** method of part 1, 7.2, which puts the enclosure in a
  diffuse field and measures inside it, giving $D_{p\mathrm{r}}$. It exists in part 1
  only, and asking for it in situ is refused rather than approximated;
- an **artificial** source, the tapping machine of Annex A dropped on an
  undamped steel plate, used at several positions. The positions are averaged
  **arithmetically**, which is the standard's own word and not the energy mean
  used almost everywhere else in this library, so `enclosure_artificial_source_insulation`
  writes it out rather than borrowing one.

## 3. Is the room good enough?

Annex C of part 2 asks the question the emission standards ask backwards. They
ask what the environmental correction $K_2$ of a room is; the annex asks how
much room a method needs. Holding $K_2 = 10 \lg(1 + 4S/(\alpha S_V))$ at the
limit Table C.1 sets and solving for the room gives

$$
\frac{S_V}{S} = \frac{4}{\left(10^{K_2/10} - 1\right)\alpha}
$$

which is Figure C.1 in closed form: the curve the annex asks the reader to read
off by eye. `check_enclosure_test_environment` evaluates it and compares it with
the room in front of you.

```python
verdict = noise_control.check_enclosure_test_environment(
    base_standard="ISO 3744",
    mean_absorption_coefficient=0.15,
    room_surface_area_m2=520.0,
    measurement_surface_area_m2=14.1,
)
print(round(verdict.required_area_ratio, 1))  # 45.6
print(round(verdict.actual_area_ratio, 1))    # 36.9
print(verdict.passes)                     # False
```

That room cannot carry a precision determination. It can carry a survey one,
which asks 6.6 rather than 45.6, and the answer that comes back from it is an
A-weighted value with no spectrum behind it. The two facts belong together, and
reading Table 1 after Annex C is how they stay together.

Where nobody measured the absorption, Table C.2 gives seven room descriptions
and their coefficients, from 0.05 for an empty room with smooth hard walls to
0.5 for a room with large amounts of sound-absorbing material on ceiling and
walls. They are `ROOM_ABSORPTION_ESTIMATES`, transcribed from that table and
from no other. The 2010 editions of the sound power standards print a longer
table under the same title: Table A.1 of ISO 3744:2010 and of ISO 3746:2010 has
eight rows, adding 0.30 for a room with an absorbing ceiling and bare walls,
and words two of the seven differently.

### How the measurement goes

Pick the base standard first, because Table 1 decides what the result may be
called: a survey method gives an A-weighted number and nothing per band, and no
amount of care afterwards turns that into a spectrum. Fix the measurement
surface and keep it for both runs. Determine the machine's sound power without
the enclosure, fit the enclosure without moving the machine or the microphones,
and determine it again. Where the machine cannot be run twice, use the
reciprocity method or the artificial source of Annex A instead, and say which in
the report. In situ, run `check_enclosure_test_environment` on the room before
anything else: a room that cannot meet the environmental correction the base
standard asks for will not be rescued by a careful measurement.

## 4. The cabin is the inverse problem

An enclosure keeps noise **in**. A **cabin** keeps it **out**, and ISO 11957
measures that as the difference between the level in the room and the level
inside the empty cabin.

$$
D_p = (L_p)_{\text{room}} - (L_p)_{\text{cabin}}
$$

Equation (1) is the laboratory quantity, measured in a reverberation room to
ISO 3741. Equation (2) is the same arithmetic **in situ**, where no requirement
is placed on the room at all, and the answer carries a prime to say so:
$D'_p$. The prime is not decoration. Definition 3.6 exists because a number
measured in a room that was never qualified cannot be compared with one that
was, and clause 4 says outright that only data from the same method may be used
when comparing cabins.

```python
room = [88.0, 90.0, 91.0, 89.0, 86.0, 82.0]    # dB, level in the room
inside = [76.0, 72.0, 66.0, 59.0, 52.0, 47.0]  # dB, level in the cabin

cab = noise_control.cabin_insulation(
    room, inside, frequencies=bands, fraction=1,
    method="in-situ-loudspeaker",
)
print(cab.symbol, cab.rounded)   # D'_p [12 18 25 30 34 35] dB
```

There is a third method, and it is the one a workplace usually wants: drive the
room with the noise that is actually there. That is the only method for which
the standard defines an A-weighted difference, $D'_{p\mathrm{A}}$ of Equation (3), and
`cabin_insulation` refuses to compute one under any other, because a figure
labelled $D'_{p\mathrm{A}}$ that came from a loudspeaker is a claim the document does
not make.

## 5. The count that is read off the answer

Almost every number in a measurement standard is fixed before the measurement:
six microphone positions, 2 m from the cabin, 3 m apart. Clause 7.2.1 of
ISO 11957 has one that is not. The number of loudspeaker positions **shall be
at least the largest deviation, in decibels, of $D'_p$ between any two of
them**, read in octave bands, starting at three and stopping at six.

It is a criterion that judges the measurement by how much it disagreed with
itself. A room where moving the loudspeaker changes the answer by four decibels
is a room where three positions were not enough to average it out.

```python
by_position = [
    [12.0, 16.0, 25.0, 30.0, 34.0, 35.0],
    [13.5, 18.0, 27.5, 32.0, 36.5, 36.0],
    [11.0, 14.5, 23.0, 28.5, 33.0, 34.0],
]
check = noise_control.check_source_positions(by_position)
print(check.max_octave_spread_db)   # 4.5
print(check.n_required_positions)     # 5
print(check.passes)                   # False
```

Two more positions, and the clause adds that the three used first should not be
used again. Past six decibels the excess is stated in the report instead, which
`exceeds_max` marks.

The other numeric rules of the two clauses are here too. `check_band_flatness`
is the requirement that the three one-third-octave levels inside an octave
differ by at most 6 dB at 125 Hz, 5 dB at 250 Hz and 4 dB above, which is what
makes an octave-band result mean what the standard says it means.
`min_cabin_clearance_m` is the clearance of 6.2, written exactly as printed
including the low-frequency sentence that relaxes it rather than tightening it.
`internal_noise_level` is the noise the cabin's own fans make, corrected for the
background only while the margin stays between 6 dB and 10 dB, which is a
different rule from the one 6.4 applies to the insulation itself.

### How the measurement goes

Drive the room with a loudspeaker, or let the actual noise do it where the
A-weighted insulation is wanted, since Equation (3) is defined for nothing else.
Check the driving spectrum with `check_band_flatness` before trusting an
octave-band result. Take the level in the room and the level inside the empty
cabin, both corrected for their own background by the ISO 3741 rule, and keep
the cabin empty: what is being measured is the cabin, not the equipment in it.
In situ, start at three loudspeaker positions, compute the spread of the answer
between them with `check_source_positions`, and add positions until the count
the clause asks for is reached. Measure the internal noise level separately,
with the room quiet, because a cabin with its own fans has a floor of its own.

## 6. One number, and what it is worth

All three documents delegate their single number to ISO 717-1, putting their
own quantity where that standard writes the sound reduction index.

```python
rating = noise_control.weighted_cabin_insulation(
    cab.insulation[:5], method=cab.method, fraction=1,
)
print(rating.rating, rating.c, rating.ctr)   # 28 -1 -5
```

Clause 4 of ISO 11957 calls $D_{p,\mathrm{w}}$ the preferred single number and then
warns, in the same paragraph, against reading too much into it: what a cabin is
worth depends on the spectrum it stands in. The annexes answer that objection
directly. Given a spectrum, the estimated insulation is

$$
D_{p\mathrm{A},\mathrm{e}} = L_\mathrm{A} - 10 \lg \sum_i 10^{0.1\left(L_i - A_i - D_{pi}\right)}
$$

with $L_\mathrm{A}$ the A-weighted total of the same spectrum. The sign of $A_i$ is the
trap: the annex prints an attenuation, positive where the weighting takes level
away, while a library's band corrections are the correction itself. Both terms
are built here from the same table, so the answer cannot disagree with its own
inputs, and an insulation of zero returns exactly zero.

```python
spectrum = [92.0, 94.0, 95.0, 93.0, 90.0, 85.0]   # dB, the actual noise
print(round(noise_control.estimated_cabin_noise_insulation(
    spectrum, cab.insulation, frequencies=bands,
), 1))                                             # 25.6 dB
```

Against that spectrum the cabin is worth 25.6 dB(A), where its rating is 28. The
two numbers answer different questions, and the rating is not the one to put in
a hearing-conservation calculation.

## 7. What the report has to say, and what it cannot

Clause 10 of ISO 11957 is unusually candid. In the laboratory the uncertainty of
ISO 3741 carries over from 250 Hz to 10 kHz, and only while the room is at least
twenty times the volume of the cabin. The loudspeaker method in situ adds about
2 dB to the standard deviation. For the actual-noise method the clause states
nothing at all and sends a declared value to ISO 4871.

```python
u = noise_control.uncertainty_conditions(
    room_volume_m3=520.0, cabin_volume_m3=18.0, method="in-situ-loudspeaker",
)
print(round(u.volume_ratio, 1), u.ratio_satisfied)   # 28.9 True
print(u.excess_standard_deviation_db)                # 2.0
```

A measurement whose room is too small for the cabin still returns a number.
What it does not return is the uncertainty statement, and a report that quotes
one anyway is quoting a clause that excluded it.

## What this guide covers

- **Covered.** The arithmetic of all three documents. From ISO 11546-1 and -2: Equations (1)
  to (5) through `enclosure_sound_power_insulation`, `enclosure_sound_pressure_insulation`,
  `enclosure_reciprocity_insulation` and `enclosure_artificial_source_insulation`, the last
  averaging its source positions arithmetically as the clause says; Table 1 as
  data through `applicable_methods`, including the quantities each row may
  declare and the rows that give no spectrum; the ISO 717-1 rating of clause 7
  through `weighted_enclosure_insulation`; the estimate of Annex C and Annex D through
  `estimated_a_weighted_enclosure_insulation`; the leak, seal and fill ratios of the
  definitions; the source clearance of 7.2; and the whole of Annex C of part 2,
  with Table C.1, Table C.2 and Figure C.1 in closed form through
  `check_enclosure_test_environment`, cross-checked against the environmental
  correction of ISO 3744. From ISO 11957: Equations (1), (2) and (3) through
  `cabin_insulation`, with the prime of definition 3.6 and the refusal to name
  an A-weighted insulation outside the actual-noise method; the ISO 717-1 rating
  of clause 8; the estimate of Annex A; the source-position criterion of 7.2.1
  through `check_source_positions`; the flatness rule of 6.4 through
  `check_band_flatness`; the clearance of 6.2; the internal noise level of 6.7
  with its own background window; and the conditions clause 10 attaches its
  uncertainty statement to. The background correction all three hand to ISO 3741
  is `emission.reverberation_background_correction`. Ten defects in the print of
  the three documents are recorded in the
  [errata registry](https://docs.jmrp.io/phonometry/reference/errata/).

- **Not covered.** Nothing here predicts an insulation: the panel transmission loss and the
  interior correction that give a designed insertion loss are a separate page,
  and this one starts from levels that were measured. Nothing here builds or
  qualifies a test environment: the reverberation room of ISO 3741, the
  hard-walled room of ISO 3743-1 and the microphone arrays of the ISO 11200
  series belong to their own standards, and the applicability annex reads their
  requirements rather than checking a room against them. The artificial source
  of Annex A is a hardware drawing, and its plate, drop and standoff are
  constants here and nothing more. Mounting, sealing, operating every movable
  part ten times, the instrumentation classes and the report template are
  procedure, not arithmetic; the one piece of the reporting clauses that
  computes is the rounding to the nearest decibel. No worked numeric example is
  printed in any of the three documents, so nothing here reproduces one.

## See also

- [Industrial noise control](https://docs.jmrp.io/phonometry/devices/noise-control/noise-control/):
  the predicted insertion loss of a machine enclosure, which is the quantity
  this page measures rather than computes.
- [Measuring a silencer](https://docs.jmrp.io/phonometry/devices/noise-control/silencer-measurement/):
  the same distinction for a ducted silencer, and the substitution measurement
  behind a catalogue figure.
- [Sound power in a reverberation room](https://docs.jmrp.io/phonometry/devices/emission/sound-power-reverberation/):
  the determination the cabin laboratory method is carried out in, and the
  background correction all three documents delegate to.
- [Sound power in situ by comparison](https://docs.jmrp.io/phonometry/devices/emission/sound-power-in-situ/):
  one of the base standards Table 1 allows an in-situ enclosure measurement to
  rest on.
- [Airborne sound insulation ratings](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/):
  the ISO 717-1 machinery all three documents borrow for their single number.
- [Errata in published sources](https://docs.jmrp.io/phonometry/reference/errata/): a column
  headed with a standard that does not exist, a definition that points at the
  wrong annex, and a clearance rule that relaxes the one above it.
- API reference:
  [`noise_control.enclosure_insulation`](https://docs.jmrp.io/phonometry/reference/api/noise_control/enclosure-insulation/)
  and [`noise_control`: cabin insulation](https://docs.jmrp.io/phonometry/reference/api/noise_control/cabin-insulation/).

## References

- **International Organization for Standardization. (1995).** [*Acoustics — Determination of sound insulation performances of enclosures — Part 1: Measurements under laboratory conditions (for declaration purposes)*](https://www.iso.org/standard/19500.html) (ISO 11546-1:1995).
  The laboratory measurement a manufacturer declares from: Equations (1) to (5), Table 1, the reciprocity and artificial-source methods of clause 7, and the estimate of Annex C. Read from BS EN ISO 11546-1:2009, which endorses it without modification.
- **International Organization for Standardization. (1995).** [*Acoustics — Determination of sound insulation performances of enclosures — Part 2: Measurements in situ (for acceptance and verification purposes)*](https://www.iso.org/standard/21033.html) (ISO 11546-2:1995).
  The same quantities measured where the enclosure was installed, plus Annex C, which asks whether the room is good enough for the base standard at all. Read from BS EN ISO 11546-2:2009, which endorses it without modification.
- **International Organization for Standardization. (1996).** *Acoustics — Determination of sound insulation performances of cabins — Laboratory and in situ measurements* (ISO 11957:1996).
  The cabin: Equations (1), (2) and (3), the source-position criterion of 7.2.1, the flatness and background rules of 6.4 and 6.7, and the estimate of Annex A. Read from BS EN ISO 11957:2009, which endorses it without modification.
- **International Organization for Standardization. (2009).** [*Quantities and units – Part 1: General*](https://www.iso.org/standard/30669.html) (ISO 80000-1:2009).
  Annex B, B.2 and B.3, the rounding to the nearest integer that ISO 11546-1 9.4 asks of every result.
- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for reverberation test rooms*](https://www.iso.org/standard/52053.html) (ISO 3741:2010).
  The background-noise correction all three documents hand their measurements to, and the reverberation room the cabin laboratory method is carried out in.
- **International Organization for Standardization. (2013).** [*Acoustics – Rating of sound insulation in buildings and of building elements – Part 1: Airborne sound insulation*](https://www.iso.org/standard/51968.html) (ISO 717-1:2013).
  Annex C, Table C.1, the printed rating the cabin's single number of ISO 11957 clause 8 and its Annex A estimate are checked against, in the edition the cabin checks were read from.
- **International Organization for Standardization. (2020).** [*Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation*](https://www.iso.org/standard/77435.html) (ISO 717-1:2020).
  The single-number rating all three documents delegate to, with their own quantity written where it writes the sound reduction index.