# Emission Sound Pressure at a Work Station

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/emission/workstation-emission/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/emission/workstation-emission/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-06
Updated: 2026-11-16T21:36:13Z
Standards: ISO 11200:2014; ISO 11201:2010; ISO 11202:2010; ISO 11204:2010; ISO 11203:1995
Verified: 8 conformance checks (ISO 11200:2014; ISO 11204:2010) https://docs.jmrp.io/phonometry/reference/conformance/#emission-sound-pressure-level-iso-11200-group
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Emission sound pressure level at a work station by the ISO 11200 group: background and environmental corrections, K3, grades 2 and 3, ISO 4871 uncertainty.

---

The sound power level says how much noise a machine makes. It is the right
number for comparing machines and for feeding a room prediction, and it is the
wrong number for the person standing at the machine. What that person is
exposed to is the **emission sound pressure level**: the level at the work
station, with the background noise taken out and the room's reflections taken
out, so that what is left belongs to the machine.

It is the number a datasheet prints. The
[noise-emission declaration](https://docs.jmrp.io/phonometry/devices/emission/sound-power/) of
ISO 4871 carries $L_{p\mathrm{A}}$ beside $L_{W\mathrm{A}}$, and the EU
Machinery Directive requires it whenever it exceeds 70 dB(A). Five standards
determine it, and they differ in exactly one thing: how they get rid of the
room. ISO 11201 qualifies the environment until there is no room to get rid
of; ISO 11202 corrects for it approximately, by two routes; ISO 11204 corrects
for it accurately; ISO 11203 derives the level from the sound power level, so
nothing is measured at the work station itself; and ISO 11205 uses sound
intensity, a route this library does not implement.

![Five panels, one for each case of Clause 9. 9.1, operator present: the head seen from above with its centre plane dashed and the line of vision arrowed forward, and a microphone 0.20 m plus or minus 0.02 m to the side, on a line with the eyes and on the louder side. 9.2, a seat with nobody in it: a microphone 0.80 m plus or minus 0.05 m above the middle of the seat plane. 9.3, a standing position with nobody there: a microphone on a stand 1.55 m plus or minus 0.075 m above a reference point marked on the floor, the point below the centre of the operator's head. 9.4, an operator on a path: four microphones on stands above a dashed path on the floor, no more than 2 m apart, at that same height, with the levels averaged over the path. 9.5, no work station at all: a plan view of the reference box drawn around the machine with four microphone positions 1 m out from each side, at 1.55 m above the floor, of which the highest is the answer. Underneath, a note that the level at one of these positions is an emission level and not a sound power level, that the background correction K1 and the environmental correction K2 or K3 come off it, and that a peak level takes neither. At the foot, two boxes: the background at the position, with the source off at least 10 dB down for grade 1 and 6 dB for grade 2, K1 taken as zero more than 15 dB down and computed by Equation 5 when closer (5.4); and a repeated measurement, with the source turned off and on, the microphone taken away and set again, the same conditions, and the number of repetitions left to the noise test code (10.2.2).](https://docs.jmrp.io/phonometry/media/diagram_workstation_microphone.svg)

*The clause is short and those five cases are all of it: what changes is where
the microphone stands, never what is taken off what it reads.*

## 1. How the measurement goes

ISO 11201, ISO 11202 and ISO 11204 print one procedure, almost word for word,
and part company only over the room; ISO 11203 measures nothing at the work
station and has no procedure of this kind. The clause numbers below are those
of ISO 11201 and ISO 11204. ISO 11202 has one clause more ahead of the test
environment, so from clause 5 on its numbers are one higher.

1. **Test the repeatability, then choose the part.** ISO 11200:2014 puts this
   first (Figure 2): read $L'_{p\mathrm{A}}$ several times at one of the
   positions and form the standard deviation $\sigma_\mathrm{omc}$ of
   Equation (C.1). Against it stands the $\sigma_{R0}$ of the method, 0.5 dB
   at grade 1, 1.5 dB at grade 2 and 3 dB at grade 3 (Table 1 of each part): a
   machine whose own emission wanders by more than that gains nothing from the
   more exact part. Figure 3 then chooses. With only a class 2 meter,
   ISO 11202; where the machine can be measured outdoors, in a hemi-anechoic
   room or in a large hall, ISO 11201; in a very reverberant room and with
   intensity equipment, ISO 11205; where the sound power level has to be
   determined anyway, ISO 11204; where one dominating source radiates towards
   the work station, method A.1 of ISO 11202, which needs no other microphone
   position; and otherwise method A.2 or ISO 11204.
2. **Check the instruments (clause 4).** The meter with its microphone, cable
   and windscreen is class 1 to IEC 61672-1, and any filters are class 1 to
   IEC 61260. ISO 11201 accepts nothing else; ISO 11202 and ISO 11204 let a
   class 2 meter in and make the result grade 3 for it (4.1). A class 1
   calibrator goes on each microphone before and after each series of
   measurements: with nothing adjusted in between, the two readings may differ
   by 0.5 dB at most, and a series that fails that is discarded (4.2).
3. **Mount and run the machine (clause 8).** As its noise test code says, and
   exactly as for the sound power determination. Where no code exists the
   clause lists the modes to choose from (a specified load, full load, idling,
   maximum speed, the noisiest condition representative of normal use, a
   simulated load, a characteristic work cycle) and asks for the machine to be
   stabilized, at a steady temperature, before the first reading (8.5). A
   machine whose noise follows the ambient temperature, one with a
   speed-controlled cooling fan for instance, is held at 23 °C ± 2 °C (8.1).
   What was chosen is recorded in numbers, with the operational periods and
   the cycle (12.3).
4. **Place the microphone (clause 9).** One of the five cases of the figure
   above. The reference direction of the microphone points at the dominant
   source, and whenever it is practical nobody attends the machine (9.1).
   Where the level changes strongly from point to point, 9.1 recommends the
   average over a small surface centred on the work station, 0.5 m by 0.5 m
   for example.
5. **Measure with the machine running (clause 10).** $L'_{p\mathrm{A}}$, and
   $L_{p\mathrm{C,peak}}$ if it is required, for at least 10 s when the noise
   is steady and over a whole number of cycles when the machine has one; in
   frequency bands, 30 s for the bands centred on 160 Hz and below and 10 s
   from 200 Hz up (10.1). The intervals are the ones used for the sound power
   level of the same machine. A cycle of unlike periods is measured period by
   period and summed as in *A cycle of operating periods* below. For a peak
   level the interval takes in at least ten impulsive events and the highest
   peak is the one kept (10.2.3).
6. **Measure the background (5.4).** The same position and the same meter,
   with the machine switched off. The difference between the two readings
   gives $K_1$, and decides between a determination and an upper bound, by the
   margins of *The background, and where a determination stops being one*. It
   is determined for each work station.
7. **Take the room out, the way the part allows.** These are the inputs of
   *The room, and the one ratio it comes down to*.
   - ISO 11201 allows no correction, so the room is qualified instead: indoors
     at grade 2, the environmental correction $K_{2\mathrm{A}}$ of the
     reference measurement surface through the work station is 2 dB at most,
     and the machine does not radiate mainly upwards or away from the work
     station (5.2.2.1).
   - Method A.1 of ISO 11202 measures nothing more:
     $K_3 = 10 \lg (1 + 4S/A)$ with $S = 2 \pi d^2$, where $d$ is the distance
     from the work station to the dominant source and $A = \alpha S_V$ comes
     from the mean absorption coefficient and the total surface of the room
     (A.1.2). Amendment 1:2020 makes $d$ the mean of the shortest and the
     longest distance to the radiating surface, and never less than 0.5 m.
   - Method A.2 of ISO 11202 adds a path round the machine on the reference
     measurement surface, at half the height of the source, with equally
     spaced positions, often one on each side. Their energy average, taken
     from the level at the work station, is the approximate directivity index
     of Equation (A.2), and $K_2$ of that same surface comes from ISO 3744 or
     ISO 3746 (A.2.2 and A.2.3).
   - ISO 11204 averages over the positions of an enveloping surface, and
     recommends the very positions of the ISO 3744 or ISO 3746 sound power
     determination (A.1.1), then takes $K_2$ of that surface or the ratio
     $A/S_M$ (A.2 and A.3).

   With a correction, a room whose $K_{2\mathrm{A}}$ exceeds 7 dB is out of
   reach of both parts (5.2).
8. **Repeat, for $\sigma_\mathrm{omc}$.** A repetition is the whole act again
   (10.2.2): the machine switched off and on if that is feasible, the
   microphone taken away and set up again, then the same interval under the
   same conditions. For $\sigma_\mathrm{omc}$ the mounting and the operating
   conditions are readjusted each time as well, and the readings enter
   Equation (C.1) as measured, with no correction (11.2). No part prints how
   many repetitions: a noise test code may, and the case studies of ISO 11200
   Annex B use three and five.
9. **Correct, grade and report.** $L_p = L'_p - K_1 - K_3$ for the levels and
   nothing for the peak; the grade from the three gates of *What decides the
   grade*; and $U = k \sigma_\mathrm{tot}$. A value is rounded to one decimal
   place only after the last step of the calculation (12.1), and the report
   states the grade reached beside the level and its expanded uncertainty
   (clause 13).

## 2. One law, printed three times

Every measuring part of the group prints the same subtraction:

$$
L_p = L'_p - K_1 - K_3
$$

$L'_p$ is what the meter read. $K_1$ removes the background noise, $K_3$
removes the reflections the room sent back, and the difference is the machine.
ISO 11201 prints it without the $K_3$ term, not because the term is absent but
because its environment is qualified so that the term is negligible: an
essentially free field over a reflecting plane has nothing to send back.

![Two panels. On the left, the local environmental correction K3 against the dimensionless ratio z on a logarithmic axis from 0.05 to 3: a curve flat at 7 decibels up to z = 0.2, then falling as minus ten times the logarithm of z until it reaches zero at z = 1 and stays there. A dashed horizontal line marks the 4 decibel boundary between accuracy grade 2 and grade 3, with the region left of it shaded pink and the region right of it shaded green, and an annotation points at the corner to say the 7 decibel cap is minus ten times the logarithm of 0.2 to a tenth of a decibel. On the right, three bars for the worked example of a work station 1.6 metres from the source: a measured level of 76.9 decibels, a room correction of minus 3.7 floating between the other two, and the emission level of 73.2 that is left.](https://docs.jmrp.io/phonometry/media/workstation_emission.svg)

*The room correction is capped at 7 dB and vanishes above a ratio of one; where
it exceeds 4 dB the determination drops from grade 2 to grade 3.*

One rule is absolute and easy to get wrong: **a peak level takes no correction
at all**. ISO 11202 clause 8 and ISO 11204 clause 7 both say so.
$L_{p\mathrm{C,peak}}$ is reported exactly as measured, because both
corrections are derived from mean-square pressures and neither has a meaning
for a single largest excursion.

## 3. The background, and where a determination stops being one

The background correction is the same closed form the sound-power side uses,

$$
K_1 = -10 \lg \left( 1 - 10^{-0.1 \Delta L} \right), \qquad
\Delta L = L'_p - L_p(\mathrm{B})
$$

but this group puts its own thresholds around it. Past 15 dB of margin the
background is negligible and $K_1$ is taken as zero. Below 6 dB (grade 2) or
3 dB (grade 3) the correction is *held* at its value there, and the level stops
being a determination and becomes an upper bound. The library returns that fact
rather than raising, because the reading is still worth reporting; what it may
not do is go out unlabelled.

```python
from phonometry import emission

background = emission.background_noise_correction_at_workstation(79.0, 70.0)
print(round(background.correction, 1), background.upper_bound)
# 0.6 False
```

## 4. The room, and the one ratio it comes down to

Both ISO 11202 method A.2 and ISO 11204 print the same three lines, a function
of one dimensionless ratio $z$:

$$
K_3 = \begin{cases}
  7\ \mathrm{dB}, & z \le 0.2 \\
  -10 \lg z\ \mathrm{dB}, & 0.2 < z \le 1 \\
  0\ \mathrm{dB}, & z > 1
\end{cases}
$$

The 7 dB cap is not a separate rule bolted onto the curve: $-10 \lg 0.2$ is
6.99 dB, so the cap is the curve's own value rounded to the tenth of a decibel
the standard prints its corrections to. The upper branch is a floor for the
same reason a correction cannot be negative, since a room can only add to what
the microphone hears.

Two roads reach $z$, and they are the same road. ISO 11202 Equation (A.4) and
ISO 11204 Equation (A.3) go through the environmental correction $K_2$ of the
test room and the directivity $D^*_{I,\mathrm{op}}$ the work station sees;
ISO 11204 Equation (A.6) goes through the equivalent absorption area directly.
ISO 11204 A.1.2 says the two rest on the same assumptions, and under the
ISO 3744 definition $K_2 = 10 \lg (1 + 4 S_M / A)$ they are identically equal:

```python
import math
from phonometry import emission

absorption, surface = 47.0, 16.0          # m^2, the room and the surface
k2 = 10.0 * math.log10(1.0 + 4.0 * surface / absorption)

by_k2 = emission.environmental_ratio_from_k2(k2)
by_area = emission.environmental_ratio_from_absorption(absorption, surface)
print(round(by_k2, 9) == round(by_area, 9))
# True
```

With no directivity to speak of the expression collapses to
$z = 10^{-0.1 K_2}$, so $K_3 = K_2$: a work station that sees the machine no
more strongly than the measurement surface does needs the very correction the
surface needed. Only up to the cap, though. At $K_2 = 7$ dB the ratio reaches
0.2 and the correction stops following: a room with $K_2 = 10$ dB still gets
$K_3 = 7$ dB, because the cap is on $K_3$ and not on the room.

## 5. What decides the grade

Three gates decide it and the worst one wins. A class 2 sound level meter makes
the result grade 3 whatever else is true. The background must clear 6 dB for
grade 2 and 3 dB for grade 3. And the local environmental correction must not
exceed 4 dB: ISO 11202 A.1.3 puts the boundary there directly, on the
correction worked out for the farthest point of the radiating area, and
ISO 11204 5.6 puts it there too. Method A.2 is stricter. Its Condition (A.6) is
that same inequality once (A.4) and (A.5) are substituted into it, with a
margin $\Delta D^*_I$ added to the directivity index because the index is only
approximate: 0.5 dB for a source up to 1 m in its largest dimension, 1 dB up to
3 m and 1.5 dB beyond (A.2.5). Written for $K_3$, that moves the boundary down
to 3.3 dB, 2.8 dB and 2.4 dB. `grade_from_local_correction` applies the 4 dB
boundary of A.1.3 by default; give it `largest_dimension_m`, the largest
dimension of the source, and it reads the margin from that length and applies
Condition (A.6) instead.

```python
from phonometry import emission

print(emission.grade_from_local_correction(3.7))
print(emission.grade_from_local_correction(5.2))
print(emission.grade_from_local_correction(3.7, largest_dimension_m=0.8))
print(emission.grade_from_local_correction(3.2, largest_dimension_m=0.8))
# engineering
# survey
# survey
# engineering
```

The same 3.7 dB is grade 2 by A.1.3 and grade 3 by method A.2 for a source
0.8 m across, whose margin of 0.5 dB stops grade 2 at 3.3 dB. The 4.7 dB of
the method A.2 example in ISO 11200:2014 Annex B, for a machine 3 m high, is
past both, and its table prints grade 3.

## 6. The worked example, end to end

ISO 11200:2014 Annex B prints four case studies with every intermediate value.
This is the second: a machine with a clearly identifiable dominating source in
an 11 m by 8 m by 4 m assembly workshop whose reverberation time is 1.2 s, with
the work station 1.6 m from that source.

```python
import math

import numpy as np
from phonometry import emission

surface = 2.0 * math.pi * 1.6**2            # the hemisphere around the source
absorption = 0.16 * (11.0 * 8.0 * 4.0) / 1.2

ratio = emission.environmental_ratio_from_absorption(absorption, surface)
k3 = emission.local_environmental_correction(ratio)

readings = np.array([77.5, 76.0, 77.2, 77.7, 75.9])
measured = 10.0 * np.log10(np.mean(np.power(10.0, readings / 10.0)))
level = emission.emission_sound_pressure_level(measured, local_correction=k3)

sigma = emission.total_standard_deviation(1.5, 1.0)
print(round(k3, 1), round(float(measured), 1), round(float(level), 1))
print(round(sigma, 1), round(emission.emission_expanded_uncertainty(sigma), 1))
# 3.7 76.9 73.2
# 1.8 2.9
```

Every one of those five numbers is printed in Table B.2, and six conformance
rows hold the library to them.

## 7. A cycle of operating periods

A machine that idles, cuts and returns spends a different length of time in
each state, and the level of the whole cycle is the energy average weighted by
duration rather than by count:

$$
L_p = 10 \lg \left[ \frac{1}{T} \sum_{i=1}^{N} T_i\, 10^{0.1 L_{p,T_i}} \right],
\qquad T = \sum_i T_i
$$

```python
from phonometry import emission

print(round(emission.subinterval_level([80.0, 90.0], [10.0, 1.0]), 1))
# 82.6
```

Ten seconds at 80 dB carry the same energy as one second at 90, so the cycle
lands at 82.6 dB. Counting the two states equally instead would give 87.4.

## 8. Where the standard argues with itself

The two case studies of Annex B compute the same standard deviation two
different ways. Equation (C.1), printed identically in ISO 11201, ISO 11202 and
ISO 11204, is the sample standard deviation with $1/(N-1)$; Table B.3 agrees
with it and Table B.1 divides by $N$ instead. It is not cosmetic, because the
value propagates: with the figure the equation gives, Table B.1's own expanded
uncertainty would be 2.5 dB rather than the 2.4 dB it prints. The library
follows the equation and
[the errata register](https://docs.jmrp.io/phonometry/reference/errata/) records the rest.

## What this guide covers

- **Covered.** The quantities the ISO 11200 group shares: the emission sound pressure level
  `L_p = L'_p - K_1 - K_3` of ISO 11201 Equation (7), ISO 11202 Equation (10) and
  ISO 11204 Equation (9); the background correction with this group's own
  negligible and minimum margins; the piecewise local environmental correction of
  ISO 11202 Equation (A.5) and ISO 11204 Equations (A.2) and (A.5), with both
  printed routes to the ratio it is a function of; the 4 dB grade boundary of
  ISO 11202 A.1.3 and the margin Condition (A.6) adds to it for method A.2; the
  total standard deviation and expanded uncertainty; and the duration-weighted
  summation of a cycle of operating periods.

- **Not covered yet.** The measurement is described here, and none of it is computed: the microphone
  positions of Clause 9 and the qualification of the ISO 11201 environment, the
  levels round the machine that give ISO 11202 method A.2 and ISO 11204 their
  directivity index, and the determination of `K_2` or `A` by ISO 3744 or
  ISO 3746 are carried out by the user, and the library takes their results. The
  measure of sound propagation `Q` of ISO 11203 and the intensity route of
  ISO 11205 are not implemented.

## See also

- [Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/): the standardized
  routes to the sound power level, and the ISO 4871 declaration that carries
  $L_{p\mathrm{A}}$ beside $L_{W\mathrm{A}}$.
- [Sound Power by Pressure Methods](https://docs.jmrp.io/phonometry/devices/emission/sound-power-pressure/):
  the ISO 3744 environmental correction $K_2$ that the first route to $z$ goes
  through.
- [Occupational Noise Exposure](https://docs.jmrp.io/phonometry/perception/hearing/occupational-exposure/):
  what the person at the work station accumulates over a day, the
  $L_{\mathrm{EX,8h}}$ of ISO 9612.

## References

- **International Organization for Standardization. (1995).** [*Acoustics — Noise emitted by machinery and equipment — Determination of emission sound pressure levels at a work station and at other specified positions from the sound power level*](https://www.iso.org/standard/21254.html) (ISO 11203:1995).
  The route that measures no sound pressure at the work station: L_p = L_W - Q, with Q the only printed expression the document carries.
- **International Organization for Standardization. (2010).** [*Acoustics — Noise emitted by machinery and equipment — Determination of emission sound pressure levels at a work station and at other specified positions applying accurate environmental corrections*](https://www.iso.org/standard/54906.html) (ISO 11204:2010).
  The accurate route: Equation (9), the piecewise K3 of Equations (A.2) and (A.5), and the second route to the ratio in Equation (A.6).
- **International Organization for Standardization. (2010).** [*Acoustics — Noise emitted by machinery and equipment — Determination of emission sound pressure levels at a work station and at other specified positions applying approximate environmental corrections*](https://www.iso.org/standard/54907.html) (ISO 11202:2010).
  Methods A.1 and A.2: Equation (10), the K3 of Annex A and the 4 dB boundary of A.1.3.
- **International Organization for Standardization. (2010).** [*Acoustics — Noise emitted by machinery and equipment — Determination of emission sound pressure levels at a work station and at other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections*](https://www.iso.org/standard/54908.html) (ISO 11201:2010).
  The free-field method: Equation (7), the background correction of 5.4.2 and the uncertainty of clause 11.
- **International Organization for Standardization. (2014).** [*Acoustics — Noise emitted by machinery and equipment — Guidelines for the use of basic standards for the determination of emission sound pressure levels at a work station and at other specified positions*](https://www.iso.org/standard/35377.html) (ISO 11200:2014).
  The selection guide for the whole group, and the four worked case studies of Annex B that every number on this page is checked against.