# Sound Power in the Reverberation Room

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/emission/sound-power-reverberation/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/emission/sound-power-reverberation/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-28
Updated: 2026-11-16T21:36:14Z
Standards: ISO 3741:2010
Verified: 7 conformance checks (ISO 3741:2010) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Sound power in a qualified reverberation room by ISO 3741: the direct method with corrections, the comparison method, and a burst's energy level.

---

A reverberation room turns its main defect as a listening space into a
measuring instrument: because the field is diffuse, a handful of microphone
positions sample the whole radiated energy, and the sound power follows from
the mean room level and the room's absorption with no enveloping surface to
build. That is why ISO 3741 is a grade-1 (precision) method, and why it is
the laboratory route of choice for steady, broadband sources small enough to
travel to a qualified room. This guide covers the direct method through the
Sabine absorption area, the Waterhouse and meteorological corrections, the
comparison method against a reference sound source, the qualification
warnings, the accredited-style test fiche and, in section 4, the sound energy
level $L_J$ that the same two methods give a single event. Which route fits
which job, and the pressure and intensity alternatives, are weighed in
[Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/).

## 1. Reverberation room, precision grade (ISO 3741)

Both methods are defined over the **one-third-octave bands from 100 Hz to
10 kHz** (clause 8.1). Annex E extends that range down to 50 Hz informatively;
nothing extends it upwards. The lower bound is set by the room's mode density,
which is why Table 1 pairs the lowest band of interest with a minimum volume
(200 m³ at 100 Hz, 150 m³ at 125 Hz, 100 m³ at 160 Hz, 70 m³ from 200 Hz up)
and the upper bound is set by air absorption. The source under test must be no
larger than about **2 % of the room volume** (clause 1.2; up to 5 % only where a
noise test code says what that costs in uncertainty), so that it does not load
the field it is being measured in, and it must be steady over the measurement
interval: Eq. 20 energy-averages and reports a rate of energy flow, so it
characterises the machine only if the machine is time-invariant while it is
running. A single event, one press stroke or one door slam, is described by the
sound energy level $L_J$ of clause 9.2 instead, which section 4 covers.

The background must lie at least **6 dB** below the source level in the
one-third-octave bands at and below 200 Hz and at and above 6.3 kHz, and at
least **10 dB** below between 250 Hz and 5 kHz (clause 5.4.1.1), a tighter pair
of criteria than the flat 6 dB of the enveloping-surface methods, which is what
"the ISO 3741 criterion is frequency-dependent" in the parameter table below
means. Below those margins `sound_power_reverberation` clamps $K_1$ to the value
the criterion itself produces (1.26 dB and 0.46 dB respectively), warns, and the
band becomes an upper bound rather than a determination. A band whose corrected
A-weighted contribution is at least 15 dB below the largest may instead be
dropped from the range of interest altogether (clause 5.4.1.2).

In a qualified hard-walled **reverberation room** the field is diffuse, so a
handful of microphones sample the whole radiated energy and the method
reaches grade 1. The sound power comes from the mean room level
$L_p(\text{ST})$, the Sabine absorption area
$A = (55.26/c)\cdot(V/T_{60})$ and a chain of small corrections
(ISO 3741 Eq. 20):

$$
L_W = \bar{L}_p + 10 \log_{10}\frac{A}{A_0} + 4.34\ \frac{A}{S}
      + 10 \log_{10}\left( 1 + \frac{S c}{8 V f} \right) + C_1 + C_2 - 6 .
$$

The bracketed term is the **Waterhouse correction**: near the room
boundaries the sound energy density is higher than in the interior, and
this term (which vanishes as frequency grows) restores the energy the
interior microphones miss. $C_1$ (reference-quantity) and $C_2$
(radiation-impedance) carry the result to the reference meteorological
conditions of 23 °C and 101.325 kPa,

$$
C_1 = -10 \log_{10}\frac{p_\mathrm{s}}{p_{\mathrm{s}0}} + 5 \log_{10}\frac{273.15 + \theta}{314}, \qquad
C_2 = -10 \log_{10}\frac{p_\mathrm{s}}{p_{\mathrm{s}0}} + 15 \log_{10}\frac{273.15 + \theta}{296},
$$

with the speed of sound $c = 20.05\sqrt{273 + \theta}$.

Two of the five terms usually go unexplained. The **−6 dB** is the diffuse-field
relation itself: in a diffuse field the power a source feeds into the room
equals $\bar{p}^2 A/(4\rho c)$, and expressing that against the two reference
quantities leaves a constant, which for the references of these standards is
−6 dB. The **4.34 A/S** term is the first-order correction from the Sabine
absorption area towards the Eyring value; 4.34 is $10\lg e$ and $A/S$ is the
room's mean absorption coefficient, so the term is small in a hard room and
grows as the room is damped. In the example below, $A = 16.1$ m² against
$S = 220$ m², so it contributes **0.32 dB** in every band, negligible here, and
the first term to watch when the reverberation time sits near the qualification
floor. The Waterhouse term runs the other way, **1.68 dB at 100 Hz** and
0.02 dB at 10 kHz on the same data: the low bands are ruled by the boundary
energy the interior microphones miss, the high bands by the absorption area.

The right-hand panel of the clip below is the reverberation room. The same
source runs
in both rooms; in the anechoic room on the left the microphones see only what
the source sends their way, so the level falls with distance and the free-field
route has to integrate over a measurement surface, while in the reverberation
room on the right the reflected energy fills the space and the level stops
depending on where a microphone is. That is the whole reason Eq. 20 can
replace a surface integral with a handful of positions and a room constant,
and the reason the room, not the array, is what has to be qualified. Both
routes end on the same $L_W$, because sound power is a property of the source
and not of the room it is measured in.

**Video:** [Same source, two rooms, one sound power](https://docs.jmrp.io/phonometry/media/anim_power_two_rooms.webm): The same source in an anechoic room and in a reverberation room produces different microphone pressures, and the free-field and diffuse-field formulas converge to the same sound power level L_W.

### Where the microphones and the source go

![Two plans of the same ISO 3741 reverberation test room with skew hard walls. On the left the direct method: the source under test on the floor at least 1.5 m from every wall and placed asymmetrically, six numbered microphone positions each more than 1.0 m from every room surface and more than d_min from the source with a mutual spacing of at least half a wavelength, a hung diffuser, and a dashed circular path marking the continuous-traverse alternative. On the right the comparison method: the same six positions, the source under test left in place, and the reference sound source on the floor at least 1.5 m from the walls and from the source under test. A footer strip gives d_min = D1 sqrt(V/T60) worked for V = 200 cubic metres and T60 = 2 seconds, the five traverse conditions, the averaging times and the reverberation-time rule](https://docs.jmrp.io/phonometry/media/diagram_reverberation_power.svg)

Everything Eq. 20 does rests on the array being in the reverberant part of the
field, and the standard fixes that with one distance. The source sits **on the
floor, at least 1.5 m from any wall**, and in a rectangular room asymmetrically
(clause 7.3), so that it does not couple preferentially into one mode family.
The nearest microphone must then stand off by

$$
d_{\min} = D_1 \sqrt{\frac{V}{T_{60}}}, \qquad D_1 = 0.08 ,
$$

with $D_1 = 0.16$ strongly recommended below 5 kHz (clause 8.3, Eq. 8). For the
room of the example below, $V = 200$ m³ and $T_{60} = 2.0$ s, that is
$d_{\min} = 0.8$ m, or **1.6 m** at the recommended $D_1$, so a microphone
1 m from the source is already inside the near field this method is not
measuring.

If the room has not been qualified for discrete tones per Annex D, the array is
**six discrete positions**, each more than 1.0 m from any room surface, more
than $d_{\min}$ from the source, and separated from one another by at least half
a wavelength at the lowest band of interest (1.7 m at 100 Hz). A continuous
traverse may replace them for the levels themselves, provided every point on it
keeps $d_{\min}$ from the source and 1.0 m from any room surface, stays 0.5 m
clear of any diffuser, does not lie in a plane within 10° of a room surface,
and runs for at least $3\lambda$ or 10.3 m, whichever is the smaller. The six
discrete positions are still needed to estimate the standard deviations below.

Each level is time-averaged over at least **30 s** in the bands centred at and
below 160 Hz and at least **10 s** from 200 Hz up (clause 8.4.1): the low bands
need the longer interval because a diffuse field is a modal average, and there
are few modes down there to average over. A traversing microphone must cover at
least two full traverses. The background reading is taken immediately before or
immediately after the source reading, at the same positions and over the same
interval; that is what `background_levels` is, and a spectrum measured on
another day is not it.

The `SoundPowerWarning` at an inter-position spread of 1.5 dB is the entry point
to the escalation, not a defect in itself. Clause 8.4.2.2 computes the standard
deviation $s_\mathrm{M}$ of the six initial levels band by band (Eq. 10); above 1.5 dB in
any band the source is radiating significant discrete components for this room,
and the answer is *more sampling*, not a different formula: either qualify the
room per Annex D, or read the required number of positions from Table 4: six
stays six up to 160 Hz, but 400 Hz to 630 Hz goes to 12 positions for
$1.5 < s_\mathrm{M} \le 3$ dB and 24 above 3 dB, and 800 Hz upwards to 15 and 30, and
add source positions per Eq. 12 and Table 5. Averaging longer at six positions
buys nothing here, because the scatter is spatial. The number of positions, the
traverse geometry and the measurement time interval all belong in the test
report.

```python
import numpy as np
from phonometry import emission

# One-third-octave mean room SPL (dB), 100 Hz - 10 kHz, and the room's T60.
freqs = np.array([100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000,
                  1250, 1600, 2000, 2500, 3150, 4000, 5000, 6300, 8000, 10000],
                 dtype=float)
lp = np.linspace(80.0, 70.0, freqs.size)
t60 = np.full(freqs.size, 2.0)

rev = emission.sound_power_reverberation(
    lp, t60, volume=200.0, surface_area=220.0, frequencies=freqs,
    temperature_c=20.0, static_pressure_kpa=101.0,
)
print(round(rev.speed_of_sound, 1))                     # c = 343.2 m/s
print(round(float(rev.absorption_area[0]), 1))          # A = 16.1 m^2 at 100 Hz
print(round(float(rev.waterhouse_correction[0]), 2))    # 1.68 dB at 100 Hz
print(round(float(rev.sound_power_level[0]), 1))        # LW = 87.9 dB
print(round(rev.sound_power_level_a, 1))                # LWA = 92.1 dB

# Comparison method: a reference source of known LW measured at the same spots.
lw_rss = np.full(freqs.size, 85.0)
lp_rss = np.linspace(78.0, 69.0, freqs.size)
cmp = emission.sound_power_comparison(lp, lp_rss, lw_rss, frequencies=freqs, temperature_c=20.0)
print(round(float(cmp.sound_power_level[0]), 1), cmp.method)   # 86.9 comparison

rev.plot()   # reverberation-room LW spectrum, LWA in the title (needs matplotlib)
```

![The reverberation-room sound power level spectrum of the ISO 3741 example, one bar per one-third-octave band from 100 Hz to 10 kHz falling gently with frequency, with the A-weighted total of 92.1 dB(A) in the title](https://docs.jmrp.io/phonometry/media/sound_power_reverberation_result.svg)

*The mean room level carried through the absorption-area, Waterhouse and
meteorological terms of Eq. 20 gives the one-third-octave $L_W(f)$, and the
A-weighted energy sum across the 21 bands gives the $L_{W\mathrm{A}}$ in the title.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import emission

# One-third-octave mean room SPL (dB), 100 Hz - 10 kHz, and the room's T60.
freqs = np.array([100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000,
                  1250, 1600, 2000, 2500, 3150, 4000, 5000, 6300, 8000, 10000],
                 dtype=float)
lp = np.linspace(80.0, 70.0, freqs.size)
t60 = np.full(freqs.size, 2.0)
rev = emission.sound_power_reverberation(
    lp, t60, volume=200.0, surface_area=220.0, frequencies=freqs,
    temperature_c=20.0, static_pressure_kpa=101.0,
)

# rev is the ReverberationSoundPowerResult computed above. One line:
rev.plot()
plt.show()

# By hand: a bar spectrum of LW with the A-weighted total in the title.
freqs = rev.frequencies
positions = np.arange(freqs.size)
fig, ax = plt.subplots()
ax.bar(positions, rev.sound_power_level, width=0.7, color="#1f77b4")
ax.set_xticks(positions)
ax.set_xticklabels([f"{f:g}" for f in freqs], rotation=45, ha="right")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Sound power level LW [dB]")
ax.set_title(
    f"Reverberation-room sound power (ISO 3741)  "
    f"LWA = {rev.sound_power_level_a:.1f} dB(A)")
plt.show()
```

`levels` may be a 1D mean spectrum or a 2D `(NM, NB)` array averaged over
positions. When the room volume, its reverberation time or the microphone
count fail an ISO 3741 qualification criterion (Table 1 minimum volume, the
$V/S$ reverberation floor, fewer than 6 positions, or an inter-position
spread above 1.5 dB), an advisory `SoundPowerWarning` is emitted and the
result still returns.

The five terms of Eq. 20 discussed above are all fields of that same `rev`,
so the balance between them can simply be drawn:

![Stacked bars over the 21 one-third-octave bands from 100 Hz to 10 kHz showing what each term of ISO 3741 Eq. 20 contributes to the difference between the sound power level and the mean room level. The absorption-area term is a constant 12.1 dB, the 4.34 A over S term a constant 0.32 dB, the Waterhouse term falls from 1.68 dB at 100 Hz to almost nothing by 10 kHz, the meteorological terms are a fraction of a decibel and the constant minus 6 dB is drawn downwards; a line on top traces the resulting difference from 7.9 dB at 100 Hz to 6.2 dB at 10 kHz](https://docs.jmrp.io/phonometry/media/reverberation_correction_terms.svg)

*The whole of Eq. 20, band by band, on the example below. The absorption area
carries the determination; the Waterhouse term is the only one with real
frequency dependence and it lives entirely in the low bands; and the
meteorological pair is a fraction of a decibel at ordinary conditions, which
is precisely why it is worth stating that the term everyone omits, 4.34 A/S,
grows with the room's absorption rather than with frequency.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# Every term is a field of the result the first snippet of this page returns.
absorption = 10.0 * np.log10(rev.absorption_area)
eyring = 4.34 * rev.absorption_area / 220.0
terms = [("10 lg(A/A0)", absorption), ("4.34 A/S", eyring),
         ("Waterhouse", rev.waterhouse_correction),
         ("C1 + C2", np.full(freqs.size, rev.c1 + rev.c2)),
         ("-6 dB", np.full(freqs.size, -6.0))]

x = np.arange(freqs.size)
up = np.zeros(freqs.size)
down = np.zeros(freqs.size)
fig, ax = plt.subplots(figsize=(11, 5.6))
for label, values in terms:
    ax.bar(x, values, bottom=np.where(values >= 0.0, up, down), width=0.72,
           label=label)
    up = up + np.clip(values, 0.0, None)
    down = down + np.clip(values, None, 0.0)
ax.plot(x, rev.sound_power_level - lp, "o-", label="LW - Lp")
ax.set_xticks(x, [f"{f:g}" for f in freqs], rotation=60)
ax.set(xlabel="Frequency [Hz]", ylabel="Contribution to LW - Lp [dB]")
ax.legend()
plt.show()
```

### `sound_power_reverberation()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `levels` | 1D or 2D array | dB | per band, or `(NM, NB)` | Mean room SPL; 2D is energy-averaged over positions |
| `t60` | float or 1D array | s | > 0 | Room reverberation time (scalar broadcasts) |
| `volume` | float | m³ | > 0 | Room volume $V$ |
| `surface_area` | float | m² | > 0 | Total room surface $S$ (Waterhouse, $A/S$) |
| `frequencies` | 1D array | Hz | one per band | Required (Waterhouse needs $f$); enables $L_{W\mathrm{A}}$ |
| `background_levels` | 1D or 2D array | dB | matches `levels` | Per-band $K_1$ (frequency-dependent criterion) |
| `temperature_c` | float | °C | default `23.0` | Sets $c$, $C_1$, $C_2$ |
| `static_pressure_kpa` | float | kPa | default `101.325` | Sets $C_1$, $C_2$ |

Both this function and the comparison method of section 2 return a
`ReverberationSoundPowerResult`
(`sound_power_level`, `mean_pressure_level`, `absorption_area`,
`waterhouse_correction`, `background_correction`, `c1`, `c2`,
`speed_of_sound`, `sound_power_level_a`, `method`).

## 2. The comparison method (Eq. 21)

The comparison method replaces the absorption-area, Waterhouse and $C_1$ terms
by a **reference sound source** of known power $L_W(\text{RSS})$ run in the same
room, so the room itself never has to be characterised:

$$
L_W = L_W(\text{RSS}) + \left( L_p(\text{ST}) - L_p(\text{RSS}) + C_2 \right).
$$

A reference sound source is a small aerodynamic broadband source of stable
output whose band-wise sound power level has been calibrated to ISO 6926, and it
is that calibration, not the room, that the determination now rests on. The
calibrated $L_W(\text{RSS})$ is stated for reference meteorological conditions,
which is why $C_2$ survives in Eq. 21 while $C_1$ and the room terms cancel.

The procedure is two measurements and two backgrounds. The test source is
measured first, at the six positions or over the traverse of section 1. The RSS
is then run **in the same room, at the same microphone positions or the same
traverse**, with the source under test left standing where it was, and with its
own background reading (that is what `reference_background_levels` is for). The RSS
stands on the floor more than 1.5 m from the walls; the preferred position is
the one the source under test occupies, and where the source cannot be moved the
RSS goes as close to it as practicable but never closer than 1.5 m
(clause 8.6.1). One RSS position suffices even when the source under test needs
several. Both measurements must be made at the same temperature, pressure and
humidity (clause 8.6.2).

Because the RSS supplies the room constant, the minimum source-to-microphone
distance may also be taken from the RSS reading itself (clause 8.3, Eq. 9),
$d_{\min} = D_2 \cdot 10^{0.05 (L_{W\mathrm{r}} - L_{p\mathrm{r}})}$ with $D_2 = 0.4$ and 0.8
recommended below 5 kHz. On the example below, $L_{W\mathrm{r}} - L_{p\mathrm{r}} = 7$ dB in the
100 Hz band, so $d_{\min} = 0.90$ m, or 1.8 m at the recommended $D_2$, close
enough to the 0.8/1.6 m of Eq. 8 to be a useful cross-check.

What it buys and what it costs: no $T_{60}$, no volume, no surface area and no
Waterhouse term, so a room that has never been surveyed can still return a
determination, and correspondingly, `absorption_area`,
`waterhouse_correction` and `c1` come back `NaN`, because the method never
computes them. What it costs is that the result inherits the RSS calibration
whole, so a source whose ISO 6926 certificate has expired quietly biases every
band, and the RSS position has to sample the room the way the test source does
or the difference $L_p(\text{ST}) - L_p(\text{RSS})$ is measuring the two
positions rather than the two sources.

### `sound_power_comparison()` parameters

`sound_power_comparison(levels, reference_levels, reference_sound_power_levels, *, frequencies=None,
background_levels=…, reference_background_levels=…, temperature_c=23.0,
static_pressure_kpa=101.325)` takes the same room levels plus the reference
source's levels and known power.

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `reference_levels` | 1D or 2D array | dB | matches `levels` | Mean room SPL with the reference source (RSS) running |
| `reference_sound_power_levels` | 1D array or `ReferenceSourceCalibration` | dB | per band | Known sound power $L_W(\text{RSS})$ of the reference source, from its ISO 6926 calibration; a [`ReferenceSourceCalibration`](https://docs.jmrp.io/phonometry/devices/emission/free-field-qualification/) is read in the one-third octave bands at `frequencies` |
| `background_levels` | 1D or 2D array | dB | matches `levels` | Background for the test source; per-band $K_1$ on $L_p(\text{ST})$ |
| `reference_background_levels` | 1D or 2D array | dB | matches `reference_levels` | Background for the **reference** source; per-band $K_1$ on $L_p(\text{RSS})$ |

`reference_background_levels` background-corrects the reference-source room level
$L_p(\text{RSS})$ exactly as `background_levels` does for the test source;
both need `frequencies` (the ISO 3741 criterion is frequency-dependent).

## 3. The measurement report (`.report()`)

The reverberation-room result (`ReverberationSoundPowerResult`, ISO 3741)
writes a one-page PDF fiche laid out like a sound-power test sheet through
its own `.report()`, sharing the layout and the `ReportMetadata` container of
the [pressure-method fiche](https://docs.jmrp.io/phonometry/devices/emission/sound-power-pressure/#3-the-measurement-report-report).
The standard-basis line
names ISO 3741:2010 and the precision accuracy grade (grade 1) and states which
method was used, the direct method using the room equivalent absorption area
(Eq. 20) or the comparison method using a reference sound source (Eq. 21). The
per-band table lists the mean room sound-pressure level $L_p$ and the band
sound-power level $L_W$, and the boxed $L_{W\mathrm{A}}$ carries the total $L_W$ and the
determination method (the reverberation result has no expanded uncertainty $U$).
`verbose=True` adds the background correction $K_1$ and, for the direct method,
the equivalent absorption area $A$ and the Waterhouse boundary correction $C_\mathrm{w}$;
the basis strip states the correction model (Eq. 20 or Eq. 21), the applied
meteorological corrections $C_1$/$C_2$ and the speed of sound, and cites the
Annex F A-weighting.

```python
import numpy as np
from phonometry import ReportMetadata, emission

freqs = np.array([125, 250, 500, 1000, 2000, 4000, 8000], float)
# Octave-band mean room sound-pressure levels in a qualified
# reverberation room of V = 200 m3, S = 240 m2, with a uniform T60 = 2.0 s.
lp = np.array([80.0, 83.0, 85.0, 84.0, 80.0, 75.0, 68.0])
res = emission.sound_power_reverberation(
    lp, 2.0, volume=200.0, surface_area=240.0, frequencies=freqs,
    temperature_c=20.0, static_pressure_kpa=101.325,
)

res.report(
    "sound_power_reverberation.pdf",
    metadata=ReportMetadata(
        client="Example manufacturing plant",
        specimen="Hydraulic power pack (floor-standing)",
        test_room="Qualified reverberation room, V = 200 m3, T60 = 2.0 s",
        instrumentation="Class 1 sound level meter (IEC 61672-1), s/n 0042",
        laboratory="Phonometry reference example",
        report_id="EXAMPLE-3741",
        requirement=96.0,
    ),
)   # LWA = 94.3 dB(A) re 1 pW -> declared limit 96 dB(A): PASS
```

One caveat on that example: it runs Eq. 20 on **octave** bands for compactness,
and that is not a conforming ISO 3741 determination. Both methods are defined on
one-third-octave bands, and octave-band results are formed afterwards by summing
the one-third-octave band powers per Annex F (Eq. F.1), not by feeding octave
levels into Eq. 20: the Waterhouse and absorption terms are frequency-dependent
and would then be evaluated at the octave mid-frequency instead of at each third.
Section 1's example, 100 Hz to 10 kHz in thirds, is the conforming shape.

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [ISO 3741 reverberation-room sound power example report (PDF)](https://docs.jmrp.io/phonometry/media/iso3741_reverberation_power_example.pdf): One-page ISO 3741 reverberation-room sound-power determination fiche: a header with the client, the noise source, the qualified reverberation test room and the instrumentation and climate, the octave-band table (125 Hz to 8 kHz) of mean room sound-pressure levels Lp and band sound-power levels LW, the sound-power spectrum LW(f) with a nominal band axis, the boxed A-weighted sound power level LWA = 94.3 dB(A) re 1 pW with the total LW = 96.7 dB and the direct determination method, and a PASS verdict against the declared 96 dB(A) limit, closed by a basis strip stating the Eq. 20 correction model with the Sabine absorption area, the Waterhouse boundary term and the meteorological corrections C1 and C2, and the Annex F A-weighting.

Reverberation-room sound power fiche (ReverberationSoundPowerResult.report), an ISO 3741 precision-grade direct-method determination with the Waterhouse and C1/C2 corrections and the boxed LWA.

## 4. Sound energy level of a single event (clause 9.2)

Both methods above energy-average the room level and report a rate of energy
flow, so a machine that fires once and falls silent has no $L_W$ to determine.
Clause 9.2 gives it the **sound energy level** $L_J = 10\log_{10}(J/J_0)$,
$J_0 = 1$ pJ (clause 3.18), and determines it by the same two routes with the
single event time-integrated sound pressure level $L_E$ (clause 3.4) in place of
the time-averaged $L_p$: Eq. 30 is Eq. 20 with $\overline{L_E(\text{ST})}$ where
$\overline{L_p(\text{ST})}$ stood, and Eq. 31 is Eq. 21 likewise,

$$
L_J = \overline{L_E(\text{ST})} + \left[10\log_{10}\frac{A}{A_0} + 4.34\ \frac{A}{S}
+ 10\log_{10}\left(1 + \frac{S c}{8 V f}\right) + C_1 + C_2 - 6\right], \qquad
L_J = L_W(\text{RSS}) + \left(\overline{L_E(\text{ST})} - \overline{L_p(\text{RSS})}\right) + C_2 .
$$

The measurement is clause 8.5: at least **five** events at each of the six
positions, either one at a time or as one reading encompassing them all, through
an interval that contains every significant part of the event *including its
decay*, and no moving microphone for a non-repetitive impulse. Clause 9.2.1
reduces both readings to the level of one event at each position (Eq. 22, the
energy mean of $N_\mathrm{e}$ single readings, or Eq. 23, one reading less
$10\log_{10} N_\mathrm{e}$; `mean_single_event_level` on the
[pressure-methods page](https://docs.jmrp.io/phonometry/devices/emission/sound-power-pressure/#five-events-one-at-a-time-or-all-at-once)
is the same pair). Clause 9.2.2 corrects each position for its own background
by the frequency-dependent criterion of 9.1.2 (Eq. 25/26), and clause 9.2.3
energy-averages the corrected positions (Eq. 27). The background is the
time-averaged level measured over the same integration time $T$ as the events,
and it is compared as its exposure over that window,
$L_{pi(\mathrm{B})} + 10\log_{10}(T/T_0)$, so that the energies Eq. 25 subtracts
share one reference; `integration_time` is therefore required with
`background_levels`. The reasons are spelled out on the pressure-methods page
and in the [errata registry](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md).

`sound_energy_reverberation` and `sound_energy_comparison` take `levels` in the
forms the sound power functions take, plus one: a 3D `(Ne, NM, NB)` array of the
events measured one at a time, or a 1D/2D reading with `n_events=Ne` for one
measurement of several. The room of section 1 and the reference source of
section 2 serve for both:

```python
import numpy as np
from phonometry import emission

# Five door slams recorded at the six positions of the room of section 1, one at
# a time: (events, positions, bands), the 21 one-third octaves 100 Hz - 10 kHz.
thirds = np.array([100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250,
                   1600, 2000, 2500, 3150, 4000, 5000, 6300, 8000, 10000], dtype=float)
t60_thirds = np.full(thirds.size, 2.0)
slam = np.linspace(88.0, 76.0, thirds.size)      # single event level, dB re E0
rng = np.random.default_rng(3741)
slams = slam + rng.normal(0.0, 0.6, size=(5, 6, thirds.size))

slam_lj = emission.sound_energy_reverberation(
    slams, t60_thirds, volume=200.0, surface_area=220.0, frequencies=thirds,
    background_levels=np.full(thirds.size, 45.0),   # time-averaged over the same 4 s
    integration_time=4.0, temperature_c=20.0, static_pressure_kpa=101.0,
)
print(slam_lj.n_events, slam_lj.method)                    # 5 direct
print(np.round(slam_lj.sound_energy_level[:3], 1))       # [96.  94.9 94.2] dB re 1 pJ
print(round(slam_lj.sound_energy_level_a, 1))            # LJA = 99.0 dB(A)

# Comparison method: the reference source of section 2, run steadily.
slam_cmp = emission.sound_energy_comparison(
    slams, lp_rss, lw_rss, frequencies=thirds, temperature_c=20.0,
)
print(round(float(slam_cmp.sound_energy_level[0]), 1), slam_cmp.method)   # 95.0 comparison

slam_lj.plot()   # LJ per one-third octave, LJA in the title (needs matplotlib)
```

The identity with the steady chain is exact here too: the mean room level of
section 1 read as a 10 s window, $L_E = L_p + 10\log_{10}(T/T_0)$ at every
position, gives $L_J = L_W + 10$ dB in every band through the same absorption
area, Waterhouse term and $C_1$/$C_2$, which is why Eq. 30 states $L_J$ under
the reference meteorological conditions exactly as Eq. 20 states $L_W$:

```python
lp_thirds = np.linspace(80.0, 70.0, thirds.size)     # the mean room SPL of section 1
steady = emission.sound_power_reverberation(
    lp_thirds, t60_thirds, volume=200.0, surface_area=220.0, frequencies=thirds,
    temperature_c=20.0, static_pressure_kpa=101.0,
)
ten_seconds = emission.sound_energy_reverberation(
    lp_thirds + 10.0, t60_thirds, volume=200.0, surface_area=220.0, frequencies=thirds,
    temperature_c=20.0, static_pressure_kpa=101.0,
)
print(np.round(ten_seconds.sound_energy_level - steady.sound_power_level, 6)[:3])   # 10.0
```

### Octave bands and the A-weighted total (Annex F)

Both methods are defined on one-third-octave bands, and Annex F forms the
octave-band and A-weighted levels afterwards, for sound power (Eq. F.1, F.2) and
sound energy (Eq. F.4, F.5) alike. The A-weighted total is the
`sound_energy_level_a` of every result above; the octave bands are the energy
sum of the three thirds $k = 3i - 2$ to $3i$ that Table F.1 assigns to octave
$i$, numbered from $k = 1$ at 50 Hz, which `octave_band_levels` applies to any
band spectrum whose thirds come in complete triplets:

```python
bands = emission.octave_band_levels(slam_lj.sound_energy_level, frequencies=thirds)
octaves, lj_octave = bands.frequencies, bands.levels
print(octaves)                        # [ 125.  250.  500. 1000. 2000. 4000. 8000.]
print(np.round(lj_octave, 1))         # [99.8 ... 87.7] dB, three thirds summed per octave
```

### `sound_energy_reverberation()` and `sound_energy_comparison()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `levels` | 1D, 2D or 3D array | dB | per band, `(NM, NB)` or `(Ne, NM, NB)` | Single event levels: per event on the first axis (Eq. 22), one reading of `n_events` events (Eq. 23), or the mean of one event |
| `t60`, `volume`, `surface_area`, `frequencies` | as in section 1 | | | Direct method only. `frequencies` is required there; the comparison method takes it only when `background_levels` is given, since the correction is per band |
| `reference_levels`, `reference_sound_power_levels`, `reference_background_levels` | as in section 2 | | | Comparison method only; the reference source is steady and keeps the 9.1.2 correction |
| `n_events` | int or None | | `>= 1`, default `None` | $N_\mathrm{e}$ encompassed by one reading (Eq. 23); at least 5 without a warning |
| `background_levels` | 1D or 2D array | dB | matches `levels` | Time-averaged background over the same window; per-position $K_{1i}$ (Eq. 25/26) |
| `integration_time` | float | s | > 0, required with `background_levels` | The window $T$; the background is compared as $L_{pi(\mathrm{B})} + 10\log_{10}(T/T_0)$ |
| `temperature_c`, `static_pressure_kpa` | float | °C, kPa | defaults `23.0`, `101.325` | Set $c$, $C_1$, $C_2$ as in section 1 |

Both return a `ReverberationSoundEnergyResult` (`sound_energy_level`,
`mean_event_level`, `absorption_area`, `waterhouse_correction`,
`background_correction`, `c1`, `c2`, `speed_of_sound`, `sound_energy_level_a`,
`method`, `n_events`, `integration_time`), with the same `NaN` fields for the
comparison method as its sound power twin, and the same qualification
warnings.

## What this guide covers

- **Covered.** The ISO 3741 reverberation-room determination (`sound_power_reverberation`):
  the direct method (Eq. 20) through the Sabine absorption area, the Waterhouse
  boundary correction and the $C_1$/$C_2$ meteorological corrections, and the
  comparison method against a reference sound source (`sound_power_comparison`,
  Eq. 21), both with per-band background correction and the Annex F A-weighted
  total, rendered as the accredited-style sound-power fiche through `.report()`.
  The sound energy level $L_J$ of a single event by the same two methods
  (`sound_energy_reverberation`, Eq. 30; `sound_energy_comparison`, Eq. 31):
  the $N_\mathrm{e}$ events reduced to one (Eq. 22/23), the per-position $K_{1i}$
  of Eq. 25 with the background compared over the same window, the Eq. 27 mean,
  and the Annex F octave-band (`octave_band_levels`, Eq. F.1/F.4) and A-weighted
  (Eq. F.2/F.5) levels.

- **Not covered.** The single event results carry no `.report()` fiche, and the averaging over
  several source positions of Eq. 24 (and Eq. 13 for $L_W$) is left to the
  caller, who supplies levels already averaged over the positions of clause
  8.4.2.4. The reverberation-room qualification
  itself (Annex C/D, eigenfrequency counting or a reference-source comparison)
  is assumed, not performed; the library only warns on the coarse advisory
  criteria ISO 3741 states explicitly (the Table 1 minimum volume, the $V/S$
  reverberation floor, fewer than 6 positions, an inter-position spread above
  1.5 dB). Choosing among the seven routes, and the ISO 4871 declaration a result
  feeds, live in [Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/).

## See also

- [Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/): choosing among the seven
  determination routes, the accuracy grades and the ISO 4871 noise-emission
  declaration.
- [Sound Power by Pressure Methods (ISO 3744 / ISO 3746 / ISO 3745)](https://docs.jmrp.io/phonometry/devices/emission/sound-power-pressure/):
  the in-situ enveloping surface and the precision anechoic array.
- [Sound Power by Intensity Scanning (ISO 9614)](https://docs.jmrp.io/phonometry/devices/emission/sound-power-intensity/):
  the routes that tolerate steady background noise.
- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): measuring the
  reverberation time $T_{60}$ that sets the Sabine absorption area.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): energy averaging and the A-weighting
  behind $L_{W\mathrm{A}}$.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/environment-transport/): the
  Waterhouse and $C_1$/$C_2$ derivations.
- API reference: [`emission`: sound power in a reverberation room](https://docs.jmrp.io/phonometry/reference/api/power/sound-power-reverberation/).
- Theory: [Sound power determination](https://docs.jmrp.io/phonometry/reference/theory/environment-transport/#sound-power-determination-iso-374437453746-iso-3741-iso-9614-123): the ISO 3741 comparison and direct methods derived from the diffuse-field relation.

## References

- **Beranek, L. L., & Mellow, T. J. (2012).** *Acoustics: Sound fields and transducers*. Academic Press. https://doi.org/10.1016/C2011-0-05897-0
  ISBN 978-0-12-391421-7. Radiation and sound fields: the diffuse-field relation between pressure and power that the reverberation-room method rests on.
- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for reverberation test rooms*](https://www.iso.org/standard/52053.html) (ISO 3741:2010).
  The direct (Eq. 20) and comparison (Eq. 21) methods of this guide, with the Waterhouse and meteorological corrections and the Table 1 qualification criteria.