# Sound Power by Pressure Methods

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/emission/sound-power-pressure/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/emission/sound-power-pressure/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-28
Updated: 2026-11-16T21:36:14Z
Standards: ISO 3744:2010; ISO 3745:2012; ISO 3746:2010
Verified: 7 conformance checks (ISO 3744:2010; ISO 3745:2012) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Sound power from sound pressure: ISO 3744 and ISO 3746 enveloping surfaces with K1 and K2, the ISO 3745 precision method, and a burst's energy level.

---

Of the standardised routes to the sound power level $L_W$, the pressure
methods are the ones that need nothing more exotic than a sound level meter:
sample the sound pressure on a surface that envelops the source, energy-average
it, correct it, and add the surface term. This guide covers the three of
them. The **enveloping-surface** methods of ISO 3744 (engineering grade) and
ISO 3746 (survey grade) work in situ, over one or more reflecting planes,
and clean the surface level with the background-noise correction $K_1$ and
the environmental correction $K_2$. The **precision method** of ISO 3745
moves the same idea into a qualified anechoic or hemi-anechoic room, where a
fixed microphone array samples the free field directly and the grade-1
corrections are meteorological rather than environmental. Section 3 renders
the determination as the accredited-style test fiche, and section 4 turns the
enveloping surface of ISO 3744 and ISO 3746 on a source that does not run
steadily at all, the noise burst whose descriptor is the sound energy level
$L_J$ of clause 8.3. That route is theirs alone: ISO 3745 defines no sound
energy level. Which
route fits which job, and the reverberation-room and intensity alternatives,
are weighed in [Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/).

## 1. Enveloping surface, sound pressure (ISO 3744 / ISO 3746)

Place the source on a reflecting plane and imagine a **measurement surface**
of area $S$ wrapping it: a hemisphere for a compact source, a box (right
parallelepiped) for a large or elongated one. Sample the sound pressure
level at an array of microphone positions on that surface, energy-average
them, and the sound power follows because a diffuse-enough surface captures
all the radiated energy:

$$
\overline{L'_p} = 10\log_{10}\left( \frac{1}{N_\mathrm{M}} \sum_i 10^{L'_{pi}/10} \right), \qquad
L_W = \overline{L'_p} - K_1 - K_2 + 10\log_{10}\frac{S}{S_0},\quad S_0 = 1\ \text{m}^2 .
$$

The prime marks what the average is taken over: here it is the **uncorrected**
position levels, and $K_1$ and $K_2$ are subtracted from the mean afterwards, so
$\overline{L'_p}$ is `mean_pressure_level` and $\overline{L'_p} - K_1 - K_2$ is
`surface_pressure_level`. Section 2's ISO 3745 average is built the other way
round and the primes are the only warning of it.

Two corrections clean up the surface level. The **background-noise
correction** removes the energy that would have been there with the source
switched off, from the margin $\Delta L_p$ between source-on and background
levels,

$$
K_1 = -10\log_{10}\left( 1 - 10^{-\Delta L_p/10} \right),
$$

and the **environmental correction** removes the reverberant build-up of the
test room from its equivalent absorption area $A$,

$$
K_2 = 10\log_{10}\left( 1 + \frac{4 S}{A} \right).
$$

The surface area is a closed form of the geometry: a hemisphere is
$S = 2\pi r^2$ over one reflecting plane (halved and quartered for two and
three planes), and a one-plane box is $S = 4(ab + bc + ca)$ with
$a = 0.5\,l_1 + d$, $b = 0.5\,l_2 + d$, $c = l_3 + d$ for measurement distance
$d$. ISO 3746 (survey) shares every formula but is coarser: fewer
microphone positions, a 3 dB background criterion instead of 6 dB, and
validity up to $K_2 \le 7\ \text{dB}$ instead of 4 dB.

### Sizing the surface

Neither $r$ nor $d$ is a free choice, and both are measured from the
**reference box**: the smallest right parallelepiped that just encloses the
source, of sides $l_1 \times l_2 \times l_3$, standing on the reflecting plane
(clause 7.1). Its origin $O$ is the centre of the box formed with its images in
the adjoining planes, and the **characteristic source dimension** $d_0$ is the
distance from $O$ to the farthest corner of the reference box:

$$
d_0 = \sqrt{(l_1/2)^2 + (l_2/2)^2 + l_3^2}
$$

over one reflecting plane, with $l_1$ un-halved over two planes and both $l_1$
and $l_2$ un-halved over three. That is the $d_0$ the figure below labels, and
the standard then bounds the surface with it: the hemisphere radius shall be at
least $2 d_0$, not less than 1 m and not more than 16 m (clause 7.2.3; 0.5 m is
allowed only for small products over a limited frequency range), and the box
measurement distance shall be at least 0.25 m and preferably 1 m or more
(clause 7.2.4, with a note that $d < 0.5$ m limits the low-frequency range).

Worked on a 1.4 × 0.9 × 1.1 m floor-standing machine:
$d_0 = \sqrt{0.7^2 + 0.45^2 + 1.1^2} = 1.38$ m, so a hemisphere needs
$r \ge 2.8$ m and $S = 2\pi r^2 = 49.3$ m². The same machine boxed at $d = 1$ m
gives $a = 1.7$ m, $b = 1.45$ m, $c = 2.1$ m and
$S = 4(2.47 + 3.05 + 3.57) = 36.3$ m² (a quarter less surface), and a surface
that stays inside a normal test hall. That is the usual reason a large or
elongated source is boxed rather than domed, and clause 7.2.3 makes it explicit:
where the required radius grows so large that the clause 4 environment
requirements no longer hold, a hemisphere should not be used at all.

Read backwards, this also bounds the examples on this page. The `radius=1.5`
below is legitimate for a source of $d_0 \le 0.75$ m (a benchtop appliance or a
small pump), and not for the 1.4 m machine just worked; the `radius=4.0` of the
report example in section 3 covers $d_0$ up to 2 m.

![Measurement surfaces of ISO 3744: a hemisphere of radius r enveloping a compact source on a reflecting plane, with the ten Annex B microphone positions marked, and a right parallelepiped (box) at measurement distance d around a large source](https://docs.jmrp.io/phonometry/media/diagram_sound_power_surfaces.svg)

The box surface carries its own array, and it is not the Annex B hemisphere
array: `measurement_positions` deliberately raises for a box, because
ISO 3744 defines those positions by **area subdivision** instead (Annex C,
normative). Each of the five planes of the measurement surface is considered on
its own and divided into equal partial areas whose side does not exceed $3d$;
the key positions are then the centre of every partial area plus its corners,
excluding the corners that intrude into the reflecting plane, which gives a
minimum of nine positions when one partial area covers each plane (clause C.1;
ten for a triangular subdivision). The survey method keeps only the partial-area
centres. The reference direction of each microphone is normal to its face,
except at a corner of the surface, where it points at the origin $O$ of the
reference box (clause 7.2.2).

![Top view and side view of the ISO 3744 parallelepiped measurement surface around a 1.4 by 0.9 by 1.1 metre reference box at a measurement distance of 1 m, giving 2a = 3.4 m, 2b = 2.9 m, c = 2.1 m and S = 36.3 square metres. Each visible face is divided by a dashed line into equal partial areas because the 3.4 m side exceeds the 3d limit, key microphone positions are marked at the partial-area centres and at their corners except those in the reflecting plane, one position carries an arrow normal to its face and one corner position an arrow aimed at the origin O of the reference box](https://docs.jmrp.io/phonometry/media/diagram_box_array.svg)

### Setting up the measurement

`levels_positions` is not any array of decibels: it is the per-position,
per-band **time-averaged** level with the source running in its declared
operating mode, taken through a chain the standard specifies. The whole
instrumentation system (microphones, cables and the windscreen if one is
fitted) shall meet IEC 61672-1 class 1, and the filters IEC 61260 class 1
(clause 5.1). A class 1 IEC 60942 sound calibrator is applied to each microphone
**before and after** each series to check the whole measuring chain, and, with
no adjustment in between, the two readings shall differ by no more than
**0.5 dB**; beyond that the series is discarded, not corrected (clause 5.2). The
system's own compliance is verified in a traceable laboratory at intervals not
exceeding two years, the calibrator's at intervals not exceeding one year. The
mechanics of that check are on
[Calibration](https://docs.jmrp.io/phonometry/signals/metrology/calibration/).

Each microphone is oriented with its reference direction normal to the
measurement surface, and at a corner of a box surface pointing at the origin $O$
(clause 7.2.2), which is why a free-field capsule and a diffuse-field capsule
are aimed differently on the same stand.

Each level is time-averaged over a typical period of operation: the interval
**should be 20 s or longer and shall be at least 10 s**, and it has to be stated
in the test report (clause 8.2.1). A traversing microphone integrates over an
integer number of full traverses, and at least two. The background reading is
taken **immediately before or immediately after** the source reading, at the
same positions and over the same interval; so `background_levels` is a
same-day, same-array `(NM, NB)` measurement, not a spectrum copied from another
session, and pairing mismatched readings is the most common way a $K_1$ ends up
wrong.

```python
import numpy as np
from phonometry import emission

# Octave-band SPL (dB) at the 10 hemisphere positions of ISO 3744 (Annex B),
# with the source running, plus the background spectrum with it switched off.
freqs = np.array([63, 125, 250, 500, 1000, 2000, 4000, 8000])
base = np.array([70.0, 74.0, 78.0, 80.0, 79.0, 76.0, 72.0, 66.0])
rng = np.random.default_rng(0)
levels = base + rng.normal(0.0, 0.5, size=(10, 8))     # (positions, bands)
background = np.full((10, 8), 55.0)

# ISO 3744 Annex B microphone coordinates on a radius-1.5 m hemisphere.
mic_xyz = emission.measurement_positions("hemisphere", radius=1.5, n_reflecting_planes=1)
print(mic_xyz.shape)                                    # (10, 3)

res = emission.sound_power_pressure(
    levels, "hemisphere", radius=1.5, n_reflecting_planes=1,
    background_levels=background, frequencies=freqs,
    room=emission.RoomEnvironment(reverberation_time=0.6, volume=300.0),  # -> K2
)
print(round(res.surface_area, 2))                       # 14.14 m^2 (= 2*pi*1.5^2)
print(round(float(res.environmental_correction[0]), 2)) # K2 = 2.32 dB
print(round(res.sound_power_level_a, 1))                # LWA = 92.4 dB
print(round(res.uncertainty, 1))                        # U = 3.0 dB (2*sigma_R0)
print(np.round(res.sound_power_level, 1))               # per-band LW

res.plot()   # sound power level bars per band, LWA in the title (needs matplotlib)
```

![The enveloping-surface sound power level spectrum of the ISO 3744 hemisphere example, one bar per octave band from 63 Hz to 8 kHz peaking near 500 Hz, with the A-weighted total of 92.4 dB(A) in the title](https://docs.jmrp.io/phonometry/media/sound_power_pressure_result.svg)

*One bar per band: the energy-averaged surface pressure minus the background
($K_1$) and environmental ($K_2$) corrections plus the surface term
$10\log_{10}(S/S_0)$ gives $L_W(f)$, and the A-weighted energy sum across bands
gives the single-number $L_{W\mathrm{A}}$ in the title.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import emission

# Octave-band SPL (dB) at the 10 hemisphere positions of ISO 3744 (Annex B),
# with the source running, plus the background spectrum with it switched off.
freqs = np.array([63, 125, 250, 500, 1000, 2000, 4000, 8000])
base = np.array([70.0, 74.0, 78.0, 80.0, 79.0, 76.0, 72.0, 66.0])
rng = np.random.default_rng(0)
levels = base + rng.normal(0.0, 0.5, size=(10, 8))     # (positions, bands)
background = np.full((10, 8), 55.0)
res = emission.sound_power_pressure(
    levels, "hemisphere", radius=1.5, n_reflecting_planes=1,
    background_levels=background, frequencies=freqs,
    room=emission.RoomEnvironment(reverberation_time=0.6, volume=300.0),  # -> K2
)

# res is the SoundPowerResult computed above. One line:
res.plot()
plt.show()

# By hand: a bar spectrum of LW with the A-weighted total in the title.
freqs = res.frequencies
positions = np.arange(freqs.size)
fig, ax = plt.subplots()
ax.bar(positions, res.sound_power_level, width=0.7, color="#1f77b4")
ax.set_xticks(positions)
ax.set_xticklabels([f"{f:g}" for f in freqs], rotation=45, ha="right")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Sound power level LW [dB]")
ax.set_title(
    f"Enveloping-surface sound power (ISO 3744)  "
    f"LWA = {res.sound_power_level_a:.1f} dB(A)")
plt.show()
```

The A-weighted total $L_{W\mathrm{A}}$ is combined from the band powers with the
ISO 3744 Annex E A-weighting corrections, so it needs `frequencies`. Passing
a `RoomEnvironment` as `room` (`reverberation_time` + `volume`, or
`absorption_area`, or `mean_absorption_coefficient` + `room_surface`) enables
$K_2$; omit it and the field is treated as free ($K_2 = 0$). If the background margin drops below the
grade criterion or $K_2$ exceeds the validity limit, a `SoundPowerWarning`
flags that the levels are upper bounds; the determination still returns.

### K1 and K2 pitfalls

Both corrections subtract energy from the surface level, so overestimating
either one understates the emission. That is why the standards cap them, and
why most disputes over an enveloping-surface result trace back to one of
these habits:

- **$K_1$ has a cliff, not a slope.** At a 15 dB margin the correction is a
  negligible 0.14 dB; at the 6 dB engineering criterion it is already
  1.26 dB, the largest value the grade accepts. Below the criterion the
  standard does not let the formula run on: $K_1$ is capped and the result is
  reported as an upper bound. Never extrapolate the subtraction into a
  smaller margin; raise the margin (quieter site, closer surface) or switch
  to the intensity method.
- **$K_1$ assumes a stationary background.** The source-off reading must be
  taken at the same positions with the room in the same state, and the
  background energy must be the same during both readings. A ventilation
  system that cycles or a vehicle passing during either reading invalidates
  the pair; the energy subtraction also assumes source and background are
  incoherent, which holds for unrelated noise but not for the source's own
  reflections.
- **$K_2$ removes the average room build-up, not discrete reflections.** A
  nearby wall, a trolley or another machine just outside the surface adds a
  specular contribution concentrated at a few microphones. That imbalance
  shows up in the apparent directivity index $DI_i^*$, and no room-average
  correction can remove it: move the surface, remove the reflector or treat
  it with absorption.
- **$K_2$ is only as good as $A$.** With $A$ from Sabine ($0.16\,V/T$),
  errors in the reverberation time or the volume propagate directly. At the
  $K_2 = 4\ \text{dB}$ validity limit about 60 % of the measured energy is
  room, not source, and a 20 % error in $A$ still moves $L_W$ by about
  0.5 dB. Prefer a measured $T_{60}$ over a guessed absorption coefficient,
  and keep the measurement distance small enough that $K_2$ stays well under
  the limit.

![Two panels. Left: the background correction K1 against the source-to-background margin, falling steeply from 1.26 dB at the 6 dB engineering criterion through 0.46 dB at 10 dB to 0.14 dB at 15 dB, with the region below 6 dB shaded and labelled as capped and the ISO 3746 3 dB criterion marked. Right: the environmental correction K2 against 4S/A on a logarithmic axis, with the ISO 3744 4 dB and ISO 3746 7 dB validity limits drawn and annotated with the 60 % and 80 % of the measured energy that is room rather than source, and a band showing the shift when the absorption area A is known only to plus or minus 20 per cent](https://docs.jmrp.io/phonometry/media/k1_k2_corrections.svg)

*The two corrections have opposite shapes. $K_1$ is flat until the margin
closes and then rises steeply, which is why the standards cap it at the
criterion rather than let the formula run on; $K_2$ grows without bound as the
surface fills the room, and the ±20 % band shows what an estimated $A$ costs at
the validity limit.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# K1 is read out of sound_power_pressure itself, by sweeping the background
# under a fixed surface level; K2 is its own closed form.
margins = np.linspace(0.5, 20.0, 200)
k1 = [float(emission.sound_power_pressure(
          np.full((10, 1), 80.0), "hemisphere", radius=2.0,
          background_levels=np.full((10, 1), 80.0 - m),
          frequencies=np.array([1000.0])).background_correction[0])
      for m in margins]
ratio = np.geomspace(0.05, 10.0, 200)

fig, (axl, axr) = plt.subplots(1, 2, figsize=(12, 5))
axl.plot(margins, k1)
axl.axvline(6.0, linestyle="--")        # ISO 3744 criterion
axl.set(xlabel="ΔLp [dB]", ylabel="K1 [dB]", ylim=(0, 4.2))
axr.semilogx(ratio, 10.0 * np.log10(1.0 + ratio))
axr.axhline(4.0, linestyle="--")        # ISO 3744 validity limit
axr.set(xlabel="4S/A", ylabel="K2 [dB]")
plt.show()
```

One correction the enveloping-surface formula does **not** carry is
meteorological. Eq. 18 assumes the reference characteristic impedance of air, so
the determination is a determination "for the meteorological conditions at the
time and place of the test" (clause 8.2.5). At altitudes above 500 m or
temperatures below 10 °C that becomes a bias, and clause 8.2.5 then requires the
result to be carried to reference conditions per **Annex G, which is
normative**: the same kind of term the ISO 3741 and ISO 3745 sections write out
explicitly as $C_1$ and $C_2$. The size of it: clause H.4.2.7 states that below
500 m no meteorological or radiation-impedance correction is required, that at
120 m and 23 °C the correction is zero, and that at 500 m it reaches 0.6 dB.
Two of those three hold. Annex G, which is the normative text that same clause
points at, puts the correction at 0.394 dB at 500 m and 23.0 °C, and the zero at
120 m comes out exact, which is what shows its equations are being read as the
standard intends. The 0.6 dB is a misprint, and it is recorded with the
arithmetic in the [errata registry](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md).
`sound_power_pressure` implements no such term and takes no temperature or
pressure argument at all, so a determination at a mountain plant or outdoors in
winter adds the Annex G correction afterwards: `reference_atmosphere_correction`
evaluates $C_1 + C_2$ from the temperature and the static pressure (or the
altitude, through Eq. G.2), and section 4 shows it applied, since Eq. G.1 adds
it to $L_W$ exactly as Eq. G.3 adds it to $L_J$.

### `sound_power_pressure()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `levels_positions` | 2D array | dB | `(NM, NB)` | One row per position, one column per band (or a single A-weighted column) |
| `surface` | str | — | `'hemisphere'` / `'box'` | Measurement-surface shape |
| `radius` | float | m | > 0 (hemisphere) | Hemisphere radius $r$ |
| `dimensions` | (float, float, float) | m | > 0 (box) | Reference-box $(l_1, l_2, l_3)$ |
| `distance` | float | m | > 0 (box) | Measurement distance $d$ |
| `n_reflecting_planes` | int | — | `1` / `2` / `3`, default `1` | Halves/quarters the hemisphere area |
| `background_levels` | 2D array or spectrum | dB | `(NM, NB)`, or `(NB,)` / `(1, NB)` | Enables $K_1$; a single spectrum broadcasts to every position |
| `frequencies` | 1D array | Hz | nominal band centres | Enables $L_{W\mathrm{A}}$ (Annex E) |
| `room` | `RoomEnvironment` or None | — | default `None` (free field) | The room data behind $K_2$; its fields are the three routes to $A$ below |
| `room.absorption_area` | float or 1D array | m² | > 0 | $A$ for $K_2$ (direct); per-band array → per-band $K_2$ |
| `room.reverberation_time`, `room.volume` | float/array, float | s, m³ | > 0 | $A = 0.16\,V/T$ for $K_2$; per-band $T$ → per-band $K_2$ |
| `room.mean_absorption_coefficient`, `room.room_surface` | float/array, float | -, m² | `(0,1]`, > 0 | $A = \alpha\,S_v$ (Eq. A.7); per-band $\alpha$ → per-band $K_2$ |
| `grade` | str | — | `'engineering'` (default) / `'survey'` | ISO 3744 vs ISO 3746 |
| `sigma_omc_db` | float | dB | default `0.0` | $\sigma_\text{omc}$, operating/mounting instability, folded into $U$ |

Returns a `SoundPowerResult`: `sound_power_level` (per-band $L_W$),
`surface_pressure_level` ($L_p$ after $K_1$/$K_2$), `mean_pressure_level`,
`background_correction`/`environmental_correction` ($K_1$/$K_2$),
`directivity_index` (apparent $DI_i^*$ per microphone position **and** frequency
band, shape `(NM, NB)`; ISO 3744 clause 8.4), `surface_area`,
`sound_power_level_a` ($L_{W\mathrm{A}}$), `uncertainty` (expanded, 95 %) and `grade`.
`measurement_positions('hemisphere', radius=…, n_reflecting_planes=…, tones=…,
grade=…)` returns the normative `(N, 3)` microphone coordinates (Table B.1 for
tonal sources, B.2 for broadband). The survey grade takes the reduced arrays of ISO 3746 clause 8.2.1, one array
whatever the source emits: positions 4, 5, 6 and 10 of ISO 3746 Table B.1 over
one plane (the broadband positions of those numbers in ISO 3744 Table B.2), and
positions 14, 15 and 18 (two planes) or 14, 21 and 22 (three planes) of
ISO 3746 Table B.2. Beside two or three reflecting planes both standards ask
for a radius of at least 3 m (clauses B.2 and B.3 of Annex B), which the
function does not check. Those coordinates plot directly with
`plot_microphone_positions`, which draws the array on its measurement surface
in 3-D and numbers the points 1 to N in the order given, so a reduced array
such as the survey's is numbered from 1 rather than with the standard's
position numbers.

![Three-dimensional view of the ISO 3744 microphone array: ten numbered microphones on a 2 m wireframe hemisphere standing on a shaded circular reflecting plane, with positions 1 and 2 close to the plane, the others staggered in height up to positions 9 and 10 near the top, and the x, y and z axes graduated in metres](https://docs.jmrp.io/phonometry/media/microphone_positions_hemisphere.svg)

*Where the ten Annex B microphones actually sit on the 2 m hemisphere: the
heights are staggered so the array samples the whole surface evenly, which
is what lets the plain energy average of the ten levels stand in for the
surface integral.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import emission

# The 10 ISO 3744 Annex B microphones on a 2 m hemisphere.
emission.plot_microphone_positions(emission.measurement_positions("hemisphere", radius=2.0),
                                   radius=2.0)
plt.show()
```

### How many positions, and when to add more

Ten is the count for **one** reflecting plane. Against two planes the array is
the five key positions 2, 3, 6, 7 and 9 of Table B.2; in a corner, against three
planes, it is the three positions 1, 2 and 3 of Table B.3 (clause 8.1.1). The
survey method uses coarser arrays again: four positions over one plane.

Those counts are a starting point, not a result. Clause 8.1.1 requires
**additional** positions if any one of three conditions holds:

- **a)** the range of the A-weighted levels across the key positions exceeds
  10 dB over one reflecting plane, 5 dB over two, or 3 dB over three;
- **b)** the apparent A-weighted directivity index exceeds 5 dB in any
  direction;
- **c)** a large source radiates from only a small part of itself: the openings
  of an otherwise enclosed machine being the standard's own example.

The two have different answers. Condition a) is met by adding positions 11 to 20
of the same table (or, equivalently, by repeating the key array with the source
rotated −60° for Table B.1 or 180° for Table B.2): the surface is still sampled
evenly, so the plain energy average still applies. Conditions b) and c) are met
by a **localized investigation**, extra positions concentrated around the
maximum numerically equal to the level range found, and those positions carry
*unequal* segment areas, so the mean must then be the area-weighted one of
clause 8.2.2.2 and not the equal-area average `sound_power_pressure` computes.
Note 3 adds a priority rule that saves a lot of wasted work: when the background
at any position is within 6 dB of the highest source level, reduce the
background *before* adding positions, because a background that close is what is
moving $DI_i^*$ in the first place.

Both gates are one line each on the result the page has already computed:

```python
import numpy as np

# The band-summed level per position (A-weight the bands first for the
# standard's own A-weighted range; here the source is broadband enough that it
# makes no difference to the verdict).
lp_a = 10.0 * np.log10(np.sum(10.0 ** (0.1 * levels), axis=1))
print(round(float(lp_a.max() - lp_a.min()), 2))       # 0.76 dB: condition a) clear
print(round(float(np.abs(res.directivity_index).max()), 2))   # 1.1 dB: b) clear
```

$DI_i^*$ is the apparent directivity index of clause 8.4, the excess of the
background-corrected level at position $i$ over the surface average, per position
*and* per band; it is what the $K_2$ pitfall above meant by "shows up in the
apparent directivity index". A machine that radiates 5 dB more towards one
microphone than the surface average does not have a broken array: it has a
directivity the ten positions cannot resolve.

## 2. Precision grade, anechoic room (ISO 3745)

When the highest accuracy is required, ISO 3745 measures sound power in a
qualified **anechoic** or **hemi-anechoic** room, where the free field lets a
fixed array of microphones sample the radiated sound pressure directly. It is the
grade-1 counterpart to the enveloping-surface method of Section 1, with
standardized microphone coordinates, a per-position background correction and an
explicit meteorological correction.

![ISO 3745 precision sound power in an anechoic room: wedge-lined walls, the device under test at the centre and a hemispherical array of microphones at a fixed radius, with the sound power level formed from the surface-averaged pressure plus the area, background and meteorological corrections](https://docs.jmrp.io/phonometry/media/diagram_precision_anechoic.svg)

The left-hand panel of the clip below is what that room is for. With the
boundaries absorbing, a microphone sees only what the source sends its way, so
the level falls with distance and the array has to sample a whole surface,
which is why the only geometry the method needs, once the room is qualified, is
the surface term $10\log_{10}(S/S_0)$. The right-hand panel is the
reverberation-room alternative of
[ISO 3741](https://docs.jmrp.io/phonometry/devices/emission/sound-power-reverberation/), and both
end on the same $L_W$.

**Video:** [Same source, two rooms, one sound power](https://docs.jmrp.io/phonometry/media/anim_power_two_rooms.webm): The same source in an anechoic room and in a reverberation room produces different microphone pressures, and the free-field and diffuse-field formulas converge to the same sound power level L_W.

**Sound power level (Clause 8).** The band sound power level is the
surface-averaged pressure level plus the surface term and the corrections:

$$
L_W = \overline{L_p} + 10\log_{10}\frac{S}{S_0} + C_1 + C_2 + C_3,
$$

with $S = 4\pi r^2$ over the sphere or $S = 2\pi r^2$ over the hemisphere,
$S_0 = 1\ \text{m}^2$. $C_1$ and $C_2$ are the meteorological corrections
(reference and radiation-impedance terms); $C_3$ accounts for air absorption over
the measurement radius. The microphone positions are the standardized
unit-vector arrays of Tables D.1 (sphere), E.1 (hemisphere) and E.2 (hemisphere,
broadband).

There is no separate $K_1$ term in that formula because $\overline{L_p}$
(unprimed, unlike section 1's) is the surface average of the levels **after**
each one has been background-corrected on its own,

$$
\overline{L_p} = 10\log_{10}\left[\frac{1}{N_\mathrm{M}} \sum_i
10^{0.1\left(L'_{pi} - K_{1i}\right)}\right]
$$

(clause 9.4.3.1). So the correction lives inside the average, one $K_{1i}$ per
position, rather than being subtracted from the mean the way ISO 3744 does it.
`mean_pressure_level` is the raw energy average and `surface_pressure_level` the
corrected one, which is the $\overline{L_p}$ of the formula above.

**The radius is not free** (clauses 8.1/8.2). It must satisfy $r \ge 2 d_0$ with
$d_0$ the distance from the acoustic centre to the furthest point of the source
(in a hemi-anechoic room, $r \ge 2 d_0$ or $r \ge 3 h_0$, whichever is larger,
$h_0$ being the height of the acoustic centre above the floor), $r \ge \lambda/4$
at the lowest frequency of interest, and $r \ge 1$ m (0.5 m only for a small,
low-noise source over a limited band) with the whole surface inside the region
qualified per Annex A or B. Worked: a 0.6 × 0.5 × 0.7 m benchtop source has
$d_0 = \sqrt{0.3^2 + 0.25^2 + 0.7^2} = 0.80$ m, so $r \ge 1.6$ m; at a lowest
band of 100 Hz, $\lambda/4 = 0.86$ m does not bind and neither does the 1 m
floor. The `radius=1.0` of the examples below therefore fits only a source under
about 0.5 m of characteristic dimension.

**The array is not free either.** Positions 1 to 20 are used first, and 21 to 40
are added only when the difference between the highest and lowest level in any
band of interest is not less than half the number of positions; a check on data
the reader already has, `levels.max(0) - levels.min(0) >= 0.5 * levels.shape[0]`.
If 40 positions still fail it, a localized investigation is required and the
positions then carry unequal areas, which is what `areas=` is for.

```python
import numpy as np
from phonometry import emission

# The 40 standardized hemisphere positions (unit vectors scaled by the radius).
pos = emission.precision_positions("hemisphere", radius=1.0, n_positions=40)
print(pos.shape)                      # (40, 3)

# Octave/third-octave band SPL (dB) at each of the 40 positions; here a uniform
# 74 dB in one band. The result carries S = 2*pi*r^2 and LW with C1+C2+C3.
levels = np.full((40, 1), 74.0)
res = emission.sound_power_anechoic(levels, "hemisphere", radius=1.0)
print(round(res.surface_area, 3))                 # 6.283  (2*pi*1^2)
print(np.round(res.sound_power_level, 2))         # [81.85]
```

![Two three-dimensional panels of the ISO 3745 microphone arrays on a 1 m radius. Left, the 40-position hemisphere of Table E.1 over its reflecting plane, with positions 1 to 20 in one colour and 21 to 40 in another to mark the escalation. Right, the 20-position full sphere of Table D.1 for the anechoic case, with no reflecting plane](https://docs.jmrp.io/phonometry/media/precision_positions_arrays.svg)

*The precision arrays, drawn from the same `precision_positions` call the
snippet above makes. The first twenty sample the surface on their own; the
second twenty are added only when the band level range triggers the escalation,
and a localized investigation after that carries unequal areas.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

fig, (axl, axr) = plt.subplots(1, 2, subplot_kw={"projection": "3d"})
emission.plot_microphone_positions(
    emission.precision_positions("hemisphere", radius=1.0, n_positions=40),
    ax=axl, radius=1.0)
emission.plot_microphone_positions(
    emission.precision_positions("sphere", radius=1.0, n_positions=20),
    ax=axr, radius=1.0)
plt.show()
```

**Background and meteorological corrections.** The $K_1$ background correction is
applied **per position** and floored where the signal-to-background difference is
small (Eq. 11); the meteorological correction is evaluated from the measured
temperature and static pressure.

```python
import numpy as np
from phonometry import emission

# K1 for a 6 dB signal-to-background difference in a <=200 Hz edge band: the
# floor is 1.26 dB (Eq. 11). Source and background levels are [positions, bands].
k1 = emission.precision_background_correction(
    np.array([[56.0]]), np.array([[50.0]]), frequencies=np.array([200.0]))
print(round(float(k1[0, 0]), 4))      # 1.2563

# Meteorological corrections at the 23 C, 101.325 kPa reference (Eq. 16):
mc = emission.meteorological_corrections(temperature_c=23.0, static_pressure_kpa=101.325)
print(round(mc.c1, 4), round(mc.c2, 4))   # -0.1282 0.0

# Expanded uncertainty (Clause 10.5 EXAMPLE): sigma_R0 = 0.5, sigma_omc = 2.0,
# k = 2 -> U = 4.1 dB.
print(round(emission.precision_uncertainty(0.5, 2.0, 2.0), 3))   # 4.123
```

The `MeteorologicalCorrection` is a pair of scalars (plus the per-band $C_3$
when the attenuation coefficient is supplied per band) rather than a
plottable spectrum: the corrections fold into the
`PrecisionSoundPowerResult` as its `c1`/`c2`/`c3` fields, and the `.report()`
fiche prints them on its measurement-basis strip.

The margins and the intervals behind those numbers are stricter than section 1's.
The background, averaged over all positions, shall be at least **6 dB** below the
source level in every band and at least **10 dB** below from 250 Hz to 5 kHz
(clause 5.2.1.1), a band that cannot reach it may instead be excluded from the
range of interest if its corrected A-weighted band power is at least 15 dB below
the highest (clause 5.2.1.2). Where the margin falls short anyway, clause 9.4.2
freezes $K_{1i}$ at the value the criterion produces, 1.26 dB for the bands at
and below 200 Hz and at and above 6.3 kHz, 0.46 dB from 250 Hz to 5 kHz, and
then *requires* the test report, and the tables and graphs in it, to state that
those bands are upper bounds. `precision_background_correction` applies exactly
that rule; declaring the omission is the reader's job.

The averaging is longer than ISO 3744's: at least **30 s** in the bands centred
at and below 160 Hz and at least **10 s** from 200 Hz up (clause 9.4.1), with the
interval stated in the report, and at least two full traverses when a traversing
microphone is used. The background is measured immediately before or immediately
after the source, at the same positions and over the same interval. Forty
positions at 30 s in the low bands is why a grade-1 run takes so much longer than
the grade-2 one of section 1: the cost of the grade is mostly time.

### `sound_power_anechoic()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `levels_positions` | 2D array | dB | `(NM, NB)` | One row per position, one column per band |
| `surface` | str | — | `'sphere'` / `'hemisphere'` | Anechoic or hemi-anechoic room |
| `radius` | float | m | > 0 | Measurement radius $r$; bounded by $2 d_0$, $\lambda/4$ and the 1 m floor above |
| `background_levels` | 2D array or spectrum | dB | matches `levels_positions` | Enables the per-position $K_{1i}$ of Eq. 11 |
| `frequencies` | 1D array | Hz | one per band | Enables $L_{W\mathrm{A}}$ and the per-band $C_3$ |
| `areas` | 1D array | m² | one per position | Unequal segment areas, for a localized investigation (clause 9.4.3.2); equal areas assumed when omitted |
| `temperature_c` | float | °C | default `23.0` | Sets $C_1$, $C_2$ |
| `static_pressure_kpa` | float | kPa | default `101.325` | Sets $C_1$, $C_2$ |
| `air_absorption_db_per_m` | float or 1D array | dB/m | default `None` | The $C_3$ air-absorption term; supplied, not computed |
| `sigma_omc_db` | float | dB | default `0.0` | Operating and mounting standard deviation, clause 10.5 |
| `coverage_factor` | float | — | default `2.0` | $k$ in $U = k\sqrt{\sigma_{R0}^2 + \sigma_\text{omc}^2}$ |

The last two are the whole uncertainty story, and the default hides it: left
alone, `sigma_omc_db = 0` claims a perfectly repeatable installation and the fiche
prints $U = 1.0$ dB. The 4.1 dB the example below reports is what the same
determination costs once the clause 10.5 EXAMPLE value $\sigma_\text{omc} = 2.0$
dB is admitted.

Over several bands `sound_power_anechoic` returns a plottable
`PrecisionSoundPowerResult` carrying the per-band $L_W$ and the A-weighted
total:

```python
import numpy as np
from phonometry import emission

# A mid-frequency-peaked machine measured over the 40-position hemisphere array
# (Annex E). levels_positions is the (40, NB) surface pressure spectrum: a base
# spectrum peaked near 1 kHz plus a small per-position spatial spread.
freqs = np.array([125, 250, 500, 1000, 2000, 4000, 8000], float)
base = 70.0 + 8.0 * np.exp(-(np.log2(freqs / 1000.0) ** 2) / 2.0)
rng = np.random.default_rng(7)
levels = base[None, :] + rng.normal(0.0, 1.0, (40, freqs.size))

# sigma_omc_db is the operating-and-mounting standard deviation of Clause 10.5;
# with the EXAMPLE value 2.0 dB and the default coverage factor k = 2 the
# expanded uncertainty U = k*sqrt(sigma_R0^2 + sigma_omc^2) is the 4.1 dB the
# fiche below prints. Left at its default of 0 it reports 1.0 dB.
result = emission.sound_power_anechoic(levels, "hemisphere", radius=1.0,
                                       frequencies=freqs, sigma_omc_db=2.0)
print(round(result.sound_power_level_a, 1))   # 89.3
print(round(float(result.uncertainty), 1))    # 4.1  dB
result.plot()   # LW spectrum, LWA in the title (needs matplotlib)
```

![The precision sound power level spectrum of a mid-frequency-peaked machine measured over the ISO 3745 hemisphere array, one bar per band peaking near 1 kHz, with the A-weighted total of 89.3 dB(A) in the title](https://docs.jmrp.io/phonometry/media/precision_anechoic_power.svg)

*One bar per band: the surface-averaged pressure plus the area, background and
meteorological corrections give $L_W(f)$, and the A-weighted energy sum across
bands gives the single-number $L_{W\mathrm{A}}$ in the title.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import emission

# A mid-frequency-peaked machine measured over the 40-position hemisphere array
# (Annex E). levels_positions is the (40, NB) surface pressure spectrum: a base
# spectrum peaked near 1 kHz plus a small per-position spatial spread.
freqs = np.array([125, 250, 500, 1000, 2000, 4000, 8000], float)
base = 70.0 + 8.0 * np.exp(-(np.log2(freqs / 1000.0) ** 2) / 2.0)
rng = np.random.default_rng(7)
levels = base[None, :] + rng.normal(0.0, 1.0, (40, freqs.size))
result = emission.sound_power_anechoic(levels, "hemisphere", radius=1.0, frequencies=freqs)

# result is the PrecisionSoundPowerResult computed above. One line:
result.plot()
plt.show()

# By hand: a bar spectrum of LW with the A-weighted total in the title.
freqs = result.frequencies
positions = np.arange(freqs.size)
fig, ax = plt.subplots()
ax.bar(positions, result.sound_power_level, width=0.7, color="#1f77b4")
ax.set_xticks(positions)
ax.set_xticklabels([f"{f:g}" for f in freqs], rotation=45, ha="right")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Sound power level LW [dB]")
ax.set_title(
    f"Precision sound power (ISO 3745)  LWA = {result.sound_power_level_a:.1f} dB(A)")
plt.show()
```

## 3. The measurement report (`.report()`)

A sound power determination ends as a *document*. Every result of this page
stays plottable while it is being worked on (`res.plot()` draws the same
$L_W$ spectrum interactively that the fiche typesets), and the report step
wraps it into the deliverable. Both the enveloping-surface
result (`SoundPowerResult`, ISO 3744/3746) and the precision result
(`PrecisionSoundPowerResult`, ISO 3745) expose a `.report()` method that writes
a one-page PDF fiche laid out like a sound-power test sheet: the standard-basis
line naming the applied method and accuracy grade, an optional metadata header
(client, noise source, test environment, instrumentation, climate, date), a
per-band table (nominal octave/one-third-octave frequency, the surface
sound-pressure level $L_p$ and the band sound-power level $L_W$), the
sound-power spectrum $L_W(f)$ with a nominal band axis, and a boxed A-weighted
sound power level $L_{W\mathrm{A}}$ (dB re 1 pW) with the total $L_W$, the expanded
uncertainty $U$ and the measurement surface area $S$ alongside.

The metadata is supplied through a `ReportMetadata`, whose applicable fields
here are the **source description** (`specimen`), the **test environment**
(`test_room`), the **client**, the **instrumentation**, the **temperature**,
**relative humidity** and **ambient pressure**, the **date of test**
(`test_date`) and the footer identity (`laboratory`, `operator`, `report_id`,
`notes`); the measurement surface area $S$ comes from the result itself and is
printed in the result box and the basis strip, together with the applied
corrections (the background $K_1$ and environmental $K_2$ for the ISO 3744/3746
surface method, or the meteorological $C_1$/$C_2$/$C_3$ for the ISO 3745
precision method). Supplying `requirement` adds a PASS/FAIL verdict against a
declared A-weighted sound-power limit (a sound-power emission is a quantity where
less is better, so the source passes at or below the limit). `verbose=True`
adds the energy-averaged level $L_p'$ to the table, and for the ISO 3744/3746
surface result it also adds the $K_1$/$K_2$ correction columns (the precision
result has no $K_2$ at all and folds its per-position $K_1$ into the surface
average, so the fiche prints $C_1$/$C_2$/$C_3$ on its basis strip in place of
those columns). `language="es"` renders the Spanish fiche with comma decimals.

```python
import numpy as np
from phonometry import ReportMetadata, emission

freqs = np.array([63, 125, 250, 500, 1000, 2000, 4000, 8000], float)
# Ten identical position spectra over a hemisphere of radius 4 m; background a
# uniform 10 dB below and an equivalent absorption area A = 1500 m^2 (so K1, K2
# are meaningful and within the engineering validity limit).
surface = np.array([72.0, 76, 80, 82, 81, 78, 73, 66])
res = emission.sound_power_pressure(
    np.tile(surface, (10, 1)), "hemisphere", radius=4.0,
    background_levels=np.tile(surface - 10.0, (10, 1)),
    frequencies=freqs, grade="engineering",
    room=emission.RoomEnvironment(absorption_area=1500.0),
)

res.report(
    "sound_power.pdf",
    metadata=ReportMetadata(
        client="Example manufacturing plant",
        specimen="Hydraulic power pack (floor-standing)",
        test_room="Hemi-anechoic room over a reflecting floor",
        instrumentation="Class 1 sound level meter (IEC 61672-1), s/n 0042",
        laboratory="Phonometry reference example",
        report_id="EXAMPLE-3744",
        requirement=105.0,
    ),
)   # LWA = 103.7 dB(A) re 1 pW -> declared limit 105 dB(A): PASS
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [ISO 3744 sound power determination example report (PDF)](https://docs.jmrp.io/phonometry/media/iso3744_sound_power_example.pdf): One-page ISO 3744 sound-power determination fiche: a header with the client, the noise source, the hemi-anechoic test environment and the instrumentation and climate, the octave-band table (63 Hz to 8 kHz) of surface sound-pressure levels Lp and band sound-power levels LW, the sound-power spectrum LW(f) with a nominal band axis, the boxed A-weighted sound power level LWA = 103.7 dB(A) re 1 pW with the total LW = 105.8 dB, the expanded uncertainty U = 3.0 dB and the measurement surface S = 100.53 m2, and a PASS verdict against the declared 105 dB(A) limit, closed by a basis strip stating the applied K1 = 0.5 dB and K2 = 1.0 dB corrections.

Sound power determination fiche (SoundPowerResult.report), an ISO 3744 engineering-grade hemisphere measurement with the K1/K2 corrections and the boxed LWA.

The precision result writes the same sheet from the ISO 3745 side, with the
meteorological corrections on its basis strip in place of the $K_1$/$K_2$ pair.
This is the 40-position hemisphere measurement of section 2, the one whose
spectrum is plotted above:

```python
from phonometry import ReportMetadata

result.report(
    "precision-sound-power.pdf",
    metadata=ReportMetadata(
        client="Example manufacturing plant",
        specimen="Mid-frequency-peaked machine",
        test_room="Qualified anechoic room, 40-position hemisphere array",
        measurement_standard="ISO 3745",
    ),
)   # LWA = 89.3 dB(A) re 1 pW, U = 4.1 dB
```

**Report:** [ISO 3745 precision sound power determination example report (PDF)](https://docs.jmrp.io/phonometry/media/iso3745_precision_power_example.pdf): One-page ISO 3745 precision sound-power fiche: a header with the client, the noise source and the qualified anechoic room with its 40-position hemisphere array, the octave-band table from 125 Hz to 8 kHz of surface sound-pressure levels Lp and band sound-power levels LW (78.0, 79.0, 82.6, 85.8, 82.6, 78.7 and 78.0 dB), the LW spectrum peaking at 1 kHz, and the boxed A-weighted sound power level LWA = 89.3 dB(A) re 1 pW with the total LW = 90.1 dB, the expanded uncertainty U = 4.1 dB and the measurement surface S = 6.28 m2, over a basis strip stating the applied meteorological corrections C1 = -0.13 dB, C2 = 0.00 dB and C3 = 0.0 dB.

Precision sound power fiche (PrecisionSoundPowerResult.report), the ISO 3745 anechoic determination with its meteorological corrections.

## 4. Sound energy level of a burst (clause 8.3)

Everything above describes a source that runs steadily for the whole averaging
interval: Eq. 18 reports a *rate* of energy flow, and it characterises the
machine only while the machine is time-invariant. A press stroke, a door slam
or a pneumatic exhaust radiates its energy in a fraction of a second and then
stops, so the standard gives it a quantity of its own, the **sound energy
level**

$$
L_J = 10\log_{10}\frac{J}{J_0}, \qquad J = \int_{t_1}^{t_2} P(t)\,\mathrm{d}t, \qquad J_0 = 1\ \text{pJ}
$$

(clauses 3.22 and 3.23): the energy the event radiates, in decibels re 1 pJ,
in place of the power it does not have. Its determination (clause 8.3, and
clause 8.4 of ISO 3746 for the survey grade) is the chain of section 1 with one
substitution. Each microphone records the **single event time-integrated sound
pressure level**

$$
L_E = 10\log_{10}\left[\frac{\int_{t_1}^{t_2} p^2(t)\,\mathrm{d}t}{E_0}\right], \qquad E_0 = (20\ \mu\text{Pa})^2\ \text{s}
$$

(clause 3.4) through a window that encompasses the whole burst, at every
position at once (a traversing microphone is not permitted, clause 8.3.1), and
$L_E$ then goes wherever $L_p$ went: the energy average over the positions of
8.2.2 (clause 8.3.3), the background correction $K_1$ (Eq. 21) and the
environmental correction $K_2$ (Eq. 22), the surface term (Eq. 23):

$$
L_J = \overline{L'_E} - K_1 - K_2 + 10\log_{10}\frac{S}{S_0}.
$$

The two quantities meet on a steady source. Over a window of duration $T$ the
integral of a constant $p^2$ is $T p^2$, so $L_E = L_{p,T} + 10\log_{10}(T/T_0)$
with $T_0 = 1$ s (clause 3.4 NOTE 1), and the energy a steady source radiates
in $T$ seconds is $L_J = L_W + 10\log_{10}(T/T_0)$: a machine of 90 dB running
for 10 s has put out $L_J = 100$ dB. That identity is what the figure below
draws, and what the library's own tests pin the sound energy chain to, field by
field.

![Two panels. Left, the running single event level of an impact burst and of a steady 80 dB source through a 10 s window: the burst starts at 2 s and its curve is flat at 90 dB within about a second, the steady source climbs as 10 lg(t/T0) and reaches the same 90 dB at the dashed line T = 10 s; two chips read that all of the burst's 90 dB is in the first second and that the steady source's L_E is L_p plus 10 lg(T/T0), 80 plus 10. Right, seven octave-band bars from 125 Hz to 8 kHz of the burst's sound energy level over a 2 m hemisphere, rising from 95 dB at 125 Hz to 103.5 dB at 1 kHz and falling to 91 dB at 8 kHz, with the A-weighted total of 107.7 dB(A) in the title](https://docs.jmrp.io/phonometry/media/sound_energy_burst.svg)

*Left, the running single event level of an impact burst and of a steady
80 dB source through a 10 s window: the burst's 90 dB is all there within a
second of the impact, the steady source climbs as $10\log_{10}(t/T_0)$ and
reaches the same 90 dB at $T$. Right, the octave-band $L_J$ of the same press
stroke measured over a 2 m hemisphere, with the A-weighted total in the
title.*

```python
import numpy as np
from phonometry import emission

# A press stroke measured at the 10 hemisphere positions of ISO 3744 (r = 2 m),
# five strokes one at a time: (events, positions, bands), octaves 125 Hz - 8 kHz.
bands = np.array([125, 250, 500, 1000, 2000, 4000, 8000], dtype=float)
stroke = np.array([84.0, 88.0, 91.0, 92.0, 90.0, 86.0, 80.0])   # single event levels, dB
rng = np.random.default_rng(83)
events = stroke + rng.normal(0.0, 0.8, size=(5, 10, bands.size))

burst = emission.sound_energy_pressure(
    events, "hemisphere", radius=2.0,
    background_levels=np.full((10, bands.size), 62.0),   # time-averaged over the same 10 s
    integration_time=10.0, frequencies=bands,
    room=emission.RoomEnvironment(reverberation_time=1.2, volume=900.0),   # -> K2
)
print(burst.n_events)                                        # 5 (Eq. 19 over the first axis)
print(round(float(burst.environmental_correction[0]), 2))  # K2 = 2.64 dB
print(np.round(burst.sound_energy_level, 1))               # per-band LJ, peaking at 103.5 dB at 1 kHz
print(round(burst.sound_energy_level_a, 1))                # LJA = 107.7 dB(A)

burst.plot()   # LJ per band, LJA in the title (needs matplotlib)
```

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# Left: the running single event level of the two sources. The burst decays
# with a 0.35 s time constant and holds an exposure of 90 dB; the steady
# source is 80 dB, so it reaches the same 90 dB at T = 10 s.
p0_sq = (20e-6) ** 2
e0 = p0_sq * 1.0
t = np.linspace(0.0, 10.0, 4001)
dt = t[1] - t[0]
burst_p2 = np.where(t >= 2.0, (e0 * 1e9 / 0.35) * np.exp(-(t - 2.0) / 0.35), 0.0)
steady_p2 = np.full_like(t, p0_sq * 1e8)
fig, (axl, axr) = plt.subplots(1, 2, figsize=(12.5, 5.4))
with np.errstate(divide="ignore"):
    axl.plot(t, 10 * np.log10(np.cumsum(burst_p2) * dt / e0), label="impact burst")
    axl.plot(t, 10 * np.log10(np.cumsum(steady_p2) * dt / e0), label="steady, 80 dB")
axl.set(xlabel="Time [s]", ylabel="Single event level LE(t) [dB]", ylim=(60, 94))
axl.legend()

# Right: the LJ spectrum is the result computed above.
burst.plot(ax=axr)
plt.show()
```

### Five events, one at a time or all at once

The standard asks for at least **five** events (clause 8.3.1), measured either
one at a time or as one reading that spans them all, and reduces both to the
level of *one* event at each position: the energy average of the $N_\mathrm{e}$
single readings,

$$
L'_{Ei} = 10\log_{10}\left[\frac{1}{N_\mathrm{e}}\sum_{q=1}^{N_\mathrm{e}} 10^{0.1 L'_{Ei,q}}\right]
\qquad \text{(Eq. 19)},
$$

or the one reading less the $10\log_{10} N_\mathrm{e}$ of the events it holds,

$$
L'_{Ei} = L'_{Ei,N_\mathrm{e}} - 10\log_{10} N_\mathrm{e} \qquad \text{(Eq. 20)}.
$$

`sound_energy_pressure` takes the three forms `levels_positions` comes in: a
`(Ne, NM, NB)` array of the events measured one at a time (Eq. 19, as in the
snippet above), an `(NM, NB)` reading of one measurement encompassing
`n_events=Ne` events (Eq. 20), or the `(NM, NB)` mean single event level already
formed. Fewer than five events are accepted with a `SoundPowerWarning`, and
`mean_single_event_level` exposes the same reduction on its own:

```python
five_at_once = emission.mean_single_event_level(np.full((10, 1), 97.0), n_events=5)
print(round(float(five_at_once[0, 0]), 2))          # 90.01 dB: 97 - 10 lg 5 (Eq. 20)
one_by_one = emission.mean_single_event_level(np.array([89.0, 91.0, 90.0, 90.5, 89.5]))
print(round(float(one_by_one), 2))               # 90.06 dB: the energy mean (Eq. 19)
```

### The background is compared over the same window

Clause 8.3.1 has the background measured as a *time-averaged* level over the
same integration time $T$ as the events, and Eq. 21 forms $K_1$ from
$\Delta L_E = \overline{L'_E} - \overline{L_{p(\mathrm{B})}}$. Those two levels
do not share a reference: $L_E$ is an energy re $E_0 = p_0^2 \cdot 1$ s and
$L_p$ a mean-square pressure re $p_0^2$, and $K_1$ subtracts one energy from
another. The energy the background contributes to a window of $T$ seconds is
its own exposure over that window, $L_{p(\mathrm{B})} + 10\log_{10}(T/T_0)$
(the same NOTE 1 identity), so that is what `sound_energy_pressure` compares
the event level with, and why `integration_time` is required whenever
`background_levels` is given. Read literally, a 62 dB background under a 78 dB
burst in a 10 s window would look 16 dB down and earn no correction; as an
energy it is 72 dB, the margin is the 6 dB engineering criterion, and $K_1$ is
its full 1.26 dB. The [errata registry](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md)
records the reading. With the background in place, the criteria and the clamp
are section 1's: 6 dB to 15 dB for the engineering grade, 3 dB to 10 dB for the
survey grade of ISO 3746, and a `SoundPowerWarning` when a band falls below
them.

```python
# 62 dB time-averaged over 10 s is 72 dB re E0; a 78 dB burst is then 6 dB above it.
k1 = emission.sound_energy_pressure(
    np.full((10, 1), 78.0), "hemisphere", radius=2.0,
    background_levels=np.full(1, 62.0), integration_time=10.0,
).background_correction
print(round(float(k1[0]), 2))    # K1 = 1.26 dB, the value at the 6 dB criterion
```

The identity with section 1 then holds to the last digit. The same ten
positions, background and room, with every level raised by $10\log_{10}(T/T_0)$
for a 10 s window, give $L_J$ exactly 10 dB above $L_W$ in every band, and the
same $K_1$, $K_2$ and expanded uncertainty, which clause 9.1 (Eq. 24) makes
common to both quantities:

```python
# The section 1 measurement read as a 10 s window: LJ = LW + 10 lg(T/T0) exactly.
octaves_hz = np.array([63, 125, 250, 500, 1000, 2000, 4000, 8000])
rng = np.random.default_rng(0)
ten_positions = np.array([70.0, 74.0, 78.0, 80.0, 79.0, 76.0, 72.0, 66.0]) + rng.normal(0.0, 0.5, size=(10, 8))
quiet = np.full((10, 8), 55.0)
workshop = emission.RoomEnvironment(reverberation_time=0.6, volume=300.0)
steady = emission.sound_power_pressure(
    ten_positions, "hemisphere", radius=1.5, n_reflecting_planes=1,
    background_levels=quiet, frequencies=octaves_hz, room=workshop,
)
ten_seconds = emission.sound_energy_pressure(
    ten_positions + 10.0, "hemisphere", radius=1.5, n_reflecting_planes=1,
    background_levels=quiet, integration_time=10.0, frequencies=octaves_hz, room=workshop,
)
print(np.round(ten_seconds.sound_energy_level - steady.sound_power_level, 6))   # 10.0 in every band
print(round(ten_seconds.sound_energy_level_a - steady.sound_power_level_a, 6))  # 10.0
```

### Reference meteorological conditions (Annex G)

Eq. 23 holds for the meteorological conditions of the test, and above 500 m of
altitude or below 10 °C clause 8.3.6 requires the level to be carried to the
reference 101.325 kPa and 23.0 °C by Annex G, $L_{J\mathrm{ref,atm}} = L_J + C_1 + C_2$
(Eq. G.3), with

$$
C_1 = -10\log_{10}\frac{p_\mathrm{s}}{p_{\mathrm{s},0}} + 5\log_{10}\frac{273.15 + \theta}{\theta_0}, \qquad
C_2 = -10\log_{10}\frac{p_\mathrm{s}}{p_{\mathrm{s},0}} + 15\log_{10}\frac{273.15 + \theta}{\theta_1},
$$

$\theta_0 = 314$ K and $\theta_1 = 296$ K. $C_1$ is the reference-quantity
correction through the characteristic impedance of the air (omitted when $K_2$
came from the absolute comparison test of A.2), $C_2$ the radiation-impedance
correction of a monopole. Where the static pressure was not measured, Eq. G.2
estimates it from the altitude, $p_\mathrm{s} = p_{\mathrm{s},0}(1 - aH_\mathrm{a})^b$.
Annex H.4.2.7's check that the correction vanishes at 120 m and 23 °C holds to
a ten-thousandth of a decibel.

```python
# A determination at 1 200 m and 8 C, carried to 101.325 kPa and 23 C (Eq. G.3).
corr = emission.reference_atmosphere_correction(8.0, altitude=1200.0)
print(round(corr.static_pressure_kpa, 1))    # 87.7 kPa, from Eq. G.2
print(round(corr.c1, 3), round(corr.c2, 3), round(corr.total, 2))   # 0.386 0.291 0.68 dB
lj_ref = burst.sound_energy_level + corr.total    # Eq. G.3; Eq. G.1 adds the same to LW
```

### `sound_energy_pressure()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `levels_positions` | 2D or 3D array | dB | `(NM, NB)` or `(Ne, NM, NB)` | Single event levels: per-event on the first axis (Eq. 19), one reading of `n_events` events (Eq. 20), or the mean of one event |
| `surface`, `radius`, `dimensions`, `distance`, `n_reflecting_planes` | as in section 1 | | | The same measurement surface and minimum position counts |
| `n_events` | int or None | | `>= 1`, default `None` | $N_\mathrm{e}$ encompassed by one reading (Eq. 20); at least 5 without a warning |
| `background_levels` | 2D array or spectrum | dB | `(NM, NB)`, or `(NB,)` / `(1, NB)` | Time-averaged background over the same window; enables $K_1$ (Eq. 21) |
| `integration_time` | float | s | > 0, required with `background_levels` | The window $T$; the background is compared as its exposure $L_{p(\mathrm{B})} + 10\log_{10}(T/T_0)$ |
| `frequencies` | 1D array | Hz | nominal band centres | Enables $L_{J\mathrm{A}}$ (Eq. E.2) |
| `room` | `RoomEnvironment` or None | | default `None` (free field) | The room data behind $K_2$, as in section 1 |
| `grade` | str | | `'engineering'` (default) / `'survey'` | ISO 3744 clause 8.3 vs ISO 3746 clause 8.4 |
| `sigma_omc_db` | float | dB | default `0.0` | $\sigma_\text{omc}$, folded into $U$ as for $L_W$ |

Returns a `SoundEnergyResult`: `sound_energy_level` (per-band $L_J$),
`surface_event_level` ($\overline{L_E}$ after $K_1$/$K_2$, Eq. 22),
`mean_event_level` ($\overline{L'_E}$), `background_correction`/
`environmental_correction`, `directivity_index` (per position and band),
`surface_area`, `sound_energy_level_a` ($L_{J\mathrm{A}}$), `uncertainty`,
`grade`, `n_events` ($N_\mathrm{e}$, or `None` when the means were supplied) and
`integration_time`. `reference_atmosphere_correction(temperature_c,
static_pressure_kpa=…, altitude=…)` returns a `ReferenceAtmosphereCorrection`
with
`c1`, `c2`, their `total` and the `static_pressure_kpa` used.

## What this guide covers

- **Covered.** The ISO 3744/3746 enveloping-surface determination (`sound_power_pressure`):
  the hemisphere and box surface areas, the $K_1$ background and $K_2$
  environmental corrections with their validity limits, the Annex B microphone
  positions (`measurement_positions`, `plot_microphone_positions`) and the Annex
  E A-weighted total. The ISO 3745 precision determination
  (`sound_power_anechoic`): the Annex D/E fixed arrays (`precision_positions`),
  the per-position background correction (`precision_background_correction`, Eq.
  11), the meteorological corrections $C_1$/$C_2$/$C_3$ and the Clause 10.5
  expanded uncertainty (`precision_uncertainty`). Both results render the
  accredited-style sound-power fiche through `.report()`. The sound energy level
  $L_J$ of a noise burst over the same enveloping surface
  (`sound_energy_pressure`, ISO 3744 clause 8.3 and ISO 3746 clause 8.4): the
  single event levels of $N_\mathrm{e}$ events one at a time or in one reading
  (`mean_single_event_level`, Eq. 19/20), the $K_1$ of Eq. 21 with the background
  compared over the same window, $K_2$, Eq. 23 and the Annex E $L_{J\mathrm{A}}$,
  and the Annex G correction to reference meteorological conditions
  (`reference_atmosphere_correction`, Eq. G.1/G.3).

- **Not covered.** Neither determination performs the facility qualification it rests on: the
  free-field qualification of the anechoic or hemi-anechoic room is its own
  step, by ISO 26101 against the amended ISO 3745 Annex A, in
  [Free Field and Reference Sources](https://docs.jmrp.io/phonometry/devices/emission/free-field-qualification/),
  whose verdict `sound_power_anechoic` takes as `room_qualification` and warns
  on, and ISO 3744's $K_2$ validity only warns. ISO
  3744's **Annex G** correction to reference meteorological conditions, required
  above 500 m of altitude or below 10 °C (clauses 8.2.5 and 8.3.6), is evaluated
  by `reference_atmosphere_correction` but never applied inside a determination:
  `sound_power_pressure` and `sound_energy_pressure` take no temperature or
  pressure argument, and the sum is added by hand. ISO 3745 defines no sound
  energy level of its own, so a burst in the precision anechoic room has no
  route here. The $C_3$
  meteorological correction of ISO 3745 needs an air-absorption coefficient the
  caller supplies (`air_absorption_db_per_m=`); this module does not compute
  it from ISO 9613-1 itself. Choosing among the seven routes, and the ISO 4871
  declaration a result feeds, live in [Sound
  Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/).

## See also

- [Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/): choosing among the seven
  determination routes, the accuracy grades and the ISO 4871 noise-emission
  declaration.
- [Sound Power in the Reverberation Room (ISO 3741)](https://docs.jmrp.io/phonometry/devices/emission/sound-power-reverberation/):
  the precision-grade diffuse-field alternative when the source can travel
  to a qualified room.
- [Sound Power by Intensity Scanning (ISO 9614)](https://docs.jmrp.io/phonometry/devices/emission/sound-power-intensity/):
  the routes that tolerate the steady background noise a pressure method
  cannot subtract.
- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the reverberation
  time and equivalent absorption area that feed $K_2$.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): energy averaging and the A-weighting
  behind $L_{W\mathrm{A}}$.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/environment-transport/): the $K_1$/$K_2$
  and $C_1$/$C_2$ derivations.
- API reference: [`emission.sound_power`](https://docs.jmrp.io/phonometry/reference/api/power/sound-power/).
- Theory: [Sound power determination](https://docs.jmrp.io/phonometry/reference/theory/environment-transport/#sound-power-determination-iso-374437453746-iso-3741-iso-9614-123): the enveloping-surface derivation of ISO 3744/3746 and the environmental correction it needs.

## References

- **Beranek, L. L., & Mellow, T. J. (2012).** *Acoustics: Sound fields and transducers*. Academic Press. https://doi.org/10.1016/C2011-0-05897-0
  ISBN 978-0-12-391421-7. Radiation and sound fields: the free-field relations between pressure and power that the enveloping-surface and anechoic methods rest on.
- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering methods for an essentially free field over a reflecting plane*](https://www.iso.org/standard/52055.html) (ISO 3744:2010).
  The enveloping-surface method of section 1: hemisphere and box surface areas, the K1/K2 corrections, the Annex B microphone positions and the Annex E A-weighting.
- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Survey method using an enveloping measurement surface over a reflecting plane*](https://www.iso.org/standard/52056.html) (ISO 3746:2010).
  The survey grade of section 1, sharing the enveloping-surface formulae with coarser criteria.
- **International Organization for Standardization. (2012).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms*](https://www.iso.org/standard/45362.html) (ISO 3745:2012).
  The precision anechoic-room method of section 2: the Clause 8 power level, the per-position background correction (Eq. 11), the meteorological corrections and the standardized microphone arrays.