# Sound Power in Situ by Comparison (ISO 3747)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/emission/sound-power-in-situ/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/emission/sound-power-in-situ/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-02
Updated: 2026-11-16T21:36:14Z
Standards: ISO 3747:2010; ISO 3741:2010
Verified: 17 conformance checks (ISO 3747:2010; ISO 3741:2010) https://docs.jmrp.io/phonometry/reference/conformance/
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Sound power of a machine where it works, by comparison with a reference source (ISO 3747): background correction, grade and uncertainty.

---

Some machines never travel to a test room: a compressor bolted to the floor
of the plant, a press line, a packaging machine wired into the rest of the
line. ISO 3747 determines their sound power where they stand, by comparison.
A reference sound source (RSS) of calibrated band sound power is run in the
same room as the machine, the same three or four microphones listen to each
source in turn from the reverberant part of the room, and because both
sources see the same room the room cancels: the sound power of the source
under test is the calibrated power of the reference source carried across by
the difference of the two mean levels. The method reaches engineering
grade 2 where the field is reverberant enough and the source not too
directional, and survey grade 3 otherwise; an impulsive source gets a sound
energy level instead of a sound power level by the same route. This guide
covers the per-position background correction with its 6 dB and 15 dB rules,
the one- and several-location forms, the single-event path, the Table 2
grade, the clause 9 uncertainty and the Annex C reference conditions. Which
route fits which job is weighed in
[Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/).

## 1. The comparison in situ (ISO 3747)

The environment is the whole method, so the standard begins with it. The
microphone positions must lie where the field is **reverberant**, which the
standard measures as the excess of sound pressure level over the free field,
$\Delta L_f \ge 7$ dB (clause 4.1, Annex A): the level the reference source
produces at a microphone must be at least 7 dB above what it would produce
in a free field at that distance. Three or four positions are used, at
least 2 m apart, none closer than 0.5 m to any boundary, distributed as
evenly as possible round the machine, each of them either in sight of every
sound-emitting area or screened from all of them (clause 7.4.1); the
reference source goes as close to the acoustic centre as it can, for a
directional machine where it simulates the emission pattern, on top of it
where that is impractical and alongside only failing that, where positions
closer than 0.5 m to the reference box are to be avoided. One location is
normally enough; where the largest dimension of the reference box exceeds
the measurement distance the source is run at several, along the sides one
measurement distance apart when the machine is omnidirectional and one per
clearly definable emission area when it has them, and where that dimension
does not exceed the measurement distance and an omnidirectional machine
cannot take the source on top, four locations are used, one adjacent to each
vertical side of the box (clause 7.3). Both sources and the background are
read at the **same positions with the same microphone orientations**, the
reference source for 30 s (clause 7.5), and the whole determination is made
in **octave bands from 125 Hz to 8 kHz** (clause 3.11); Table D.1 tabulates
a 63 Hz row besides, for use only where the environment and the
instrumentation are satisfactory there (footnote a), which is why the API
accepts that band too.

The background is corrected **position by position** before anything is
averaged (clause 8.1, Eq. 7):

$$
K_{1i} = -10 \log_{10}\left(1 - 10^{-0.1\,\Delta L_{pi}}\right),
\qquad \Delta L_{pi} = L'_{pi(\mathrm{ST})} - L_{pi(\mathrm{B})},
$$

with three rules round it. A margin above 15 dB needs no correction at that
position. A margin between 6 dB and 15 dB takes Eq. 7, which runs from
1.26 dB at 6 dB to 0.14 dB at 15 dB. A margin **below 6 dB** caps the
correction at **1.3 dB** and reduces the accuracy of the result: the level
may still be reported, but as an upper bound, and the report must say that
the background requirement was not met. `sound_power_in_situ` applies all
three, returns the per-position $K_{1i}$ it used, and flags every band where
some margin fell below 6 dB in `background_requirement_met`, band by band,
so the flag can travel into the report with the level it qualifies; it marks
in `upper_bound` the bands where the machine's margin alone fell short, the
only ones 8.1 reads as upper bounds, since a short margin of the reference
source caps its own correction and lowers the level instead. The
reference source is corrected the same way, with the same background reading
unless it brought its own (clause 7.5 takes one reading for both), and the
corrected levels are energy-averaged over the positions (Eq. 8, 9):

$$
\overline{L_{p(\mathrm{ST})}} = 10 \log_{10}\left[\frac{1}{n}\sum_{i=1}^{n} 10^{0.1\,L_{pi(\mathrm{ST})}}\right],
\qquad L_{pi(\mathrm{ST})} = L'_{pi(\mathrm{ST})} - K_{1i}.
$$

The sound power level in each octave band is then the comparison itself
(clause 8.3.1, Eq. 11):

$$
L_W = L_{W(\mathrm{RSS})} - \overline{L_{p(\mathrm{RSS})}} + \overline{L_{p(\mathrm{ST})}} .
$$

Where the reference source was run at $m$ locations, its calibrated powers
and its per-location means are each energy-averaged over the locations first
(clause 8.3.2, Eq. 12), so a location that samples the room better does not
outvote one that samples it worse:

$$
L_W = 10 \log_{10}\left[\frac{1}{m}\sum_{j=1}^{m} 10^{0.1\,L_{Wj(\mathrm{RSS})}}\right]
- 10 \log_{10}\left[\frac{1}{m}\sum_{j=1}^{m} 10^{0.1\,\overline{L_{pj(\mathrm{RSS})}}}\right]
+ \overline{L_{p(\mathrm{ST})}} .
$$

Eq. 12 collapses to Eq. 11 when the locations are indistinguishable, and
the background correction of the reference source is evaluated per location
and per position, because the margin it comes from depends on both even
though the standard prints $K_{1i(\mathrm{RSS})}$ without the location index.

Table 1 of the standard is worth reading before placing anything, though it
is guidance and not arithmetic. It sorts the microphone positions by line of
sight: a position that sees the source under test but not the reference
source strongly overestimates the machine, one that sees the reference
source but not the machine strongly underestimates it, and where both are in
sight the sign of the error follows which of the two is nearer, vanishing
when the two measurement distances agree within 10 %. The positions to
choose are the ones in that last zone. Where they cannot all be there,
clause 7.4.3 balances the set instead, one position in a + zone, one in a
+/− zone and one or two in − zones, and Annex B recommends a single position
in the zone the machine screens. The library evaluates none of this: it
takes the levels it is given and assumes the positions were chosen well.

```python
import numpy as np
from phonometry import emission

# A floor-standing screw compressor, 2.2 m x 1.4 m x 1.8 m, that cannot
# leave the plant: four microphone positions 1.5 m from its reference box,
# one reference sound source location alongside, octave bands 125 Hz - 8 kHz.
freqs = np.array([125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0, 8000.0])
lw_rss = np.array([84.5, 88.0, 91.0, 92.5, 92.0, 90.5, 87.0])  # calibrated
st = np.array([  # L'pi(ST): one row per microphone position, dB
    [82.4, 84.9, 86.1, 85.3, 82.6, 78.4, 72.1],
    [80.9, 84.1, 85.4, 84.7, 81.8, 77.5, 71.3],
    [83.1, 85.6, 86.8, 85.9, 83.2, 79.0, 72.8],
    [81.7, 84.5, 85.8, 85.0, 82.3, 78.0, 71.7],
])
rss = np.array([  # L'pi(RSS): the reference source at the same positions
    [78.2, 81.8, 84.6, 86.0, 85.6, 84.1, 80.4],
    [77.5, 81.1, 84.0, 85.4, 85.0, 83.4, 79.8],
    [78.9, 82.4, 85.1, 86.5, 86.1, 84.6, 80.9],
    [78.0, 81.6, 84.4, 85.8, 85.4, 83.9, 80.2],
])
background = np.array([  # Lpi(B): the factory floor, loud at the low end
    [75.0, 74.0, 72.0, 70.0, 67.0, 62.0, 57.0],
    [76.5, 75.0, 73.0, 71.0, 68.0, 63.0, 58.0],
    [74.5, 73.5, 71.5, 69.5, 66.5, 61.5, 56.5],
    [75.5, 74.5, 72.5, 70.5, 67.5, 62.5, 57.5],
])

res = emission.sound_power_in_situ(
    st, rss, lw_rss, frequencies=freqs, background_levels=background,
    conditions=emission.GradeConditions(
        excess_levels=[8.2, 7.6, 8.9, 8.0],   # dLfA at each position (Annex A)
        directivity_range=4.0,                # +/-4 dB round the machine (7.2)
    ),
    sigma_omc_db=0.5,                        # a steady source (9.2 NOTE)
)
print(np.round(res.sound_power_level, 1))   # [88.8 91.5 92.6 91.8 88.9 84.7 78.6]
print(round(res.sound_power_level_a, 1))    # 96.1 dB(A)
print(res.background_requirement_met)       # [False  True  True  True  True  True  True]
print(res.upper_bound)                      # [False False False False False False False]
print(np.round(res.background_correction[1], 2))  # position 2: [1.3 0.57 0.26 0.19 0.18 0.16 0.21]
print(res.grade, res.sigma_r0, round(res.expanded_uncertainty, 1))  # engineering 1.5 3.2
```

The 125 Hz band is the one to read twice. At one of the four positions the
margin over the floor is below 6 dB for the machine, and it is below 6 dB at
every position for the quieter reference source, so both corrections take
their 1.3 dB cap there. The band fails the background requirement, which is
what the `False` says, but the 88.8 dB it reports is **no upper bound**: the
machine's capped $K_1$ reads high, the reference source's capped $K_{1i}$
reads low, and nothing says which wins, so `upper_bound` stays `False`. Every other band clears 6 dB everywhere, 250 Hz with
corrections of half a decibel that Eq. 7 evaluates rather than ignores, and
from 1 kHz up the margin passes 15 dB at two or three of the four positions,
where the correction is zero; the correction the others still take stays
below 0.25 dB.

![Two panels over the seven octave bands from 125 Hz to 8 kHz. The upper panel plots the sound pressure levels at the four microphone positions: the corrected levels of the source under test as filled blue circles with their energy mean as a blue line, the corrected levels of the reference source as green squares with their mean as a green line, the measured levels before the background correction as hollow circles joined to the corrected ones wherever the correction moved them, and the background at each position as grey crosses. A boxed note at 125 Hz says the margin is below 6 dB at that position and at every position for the reference source, both K1 are capped at 1.3 dB, and the band fails clause 8.1 and is no upper bound. The lower panel draws the resulting sound power level of the source under test as blue bars, the 125 Hz bar cross-hatched as failing the background requirement, with the calibrated sound power level of the reference source as a red dashed line with diamonds, and states in its title an A-weighted level of 96.1 dB(A), grade 2, and an expanded uncertainty of 3.2 dB with k = 2 and a 0.5 dB operating-condition deviation](https://docs.jmrp.io/phonometry/media/in_situ_sound_power.svg)

*The comparison position by position. Above, both sources at the four
microphones after the Eq. 7 correction, with the hollow markers showing
where each level was before it; the reference source sits below the machine
at the low end and above it from 1 kHz up, which is what the shape of the
calibrated curve below does to the result. Below, Eq. 11 band by band, with
the calibrated $L_{W(\mathrm{RSS})}$ beside it and the 125 Hz band, short of
the background requirement, cross-hatched.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# res is the InSituSoundPowerResult computed above. One line:
res.plot()   # LW bars, LWA in the title, the failing band cross-hatched
plt.show()

# By hand: both sources per position above, Eq. 11 below.
corrected_st = st - res.background_correction
corrected_rss = rss - res.reference_background_correction[0]
x = np.arange(freqs.size)
fig, (axt, axb) = plt.subplots(2, 1, figsize=(10, 8.4), sharex=True)
for i, offset in enumerate(np.linspace(-0.27, 0.27, st.shape[0])):
    axt.plot(x + offset, corrected_st[i], "o", color="#1f77b4")
    axt.plot(x + offset, corrected_rss[i], "s", color="#2ca02c")
    axt.plot(x + offset, background[i], "x", color="#9e9e9e")
axt.plot(x, res.mean_source_level, "-", color="#1f77b4", label="mean, source under test")
axt.plot(x, res.mean_reference_level, "-", color="#2ca02c", label="mean, reference source")
axt.set_ylabel("Sound pressure level [dB]")
axt.legend()
bars = axb.bar(x, res.sound_power_level, width=0.62, color="#1f77b4")
for bar, met, upper in zip(
    bars, res.background_requirement_met, res.upper_bound, strict=True
):
    if not met:
        bar.set_hatch("//" if upper else "xx")
axb.plot(x, res.reference_power_level, "D--", color="#d62728", label="calibrated LW(RSS)")
axb.set_xticks(x, [f"{f:g}" for f in freqs])
axb.set_xlabel("Frequency [Hz]")
axb.set_ylabel("Sound power level LW [dB re 1 pW]")
axb.legend()
plt.show()
```

A machine that is long relative to the measurement distance gets the
reference source at several locations along its sides (clause 7.3.3), and
the levels arrive as one grid per location:

```python
# The same compressor with the reference source run at two locations, one
# along each long side; the second sits nearer a wall and reads 1.2 dB lower,
# and was calibrated in a similar position 0.4 dB lower.
two = emission.sound_power_in_situ(
    st, np.stack([rss, rss - 1.2]), np.stack([lw_rss, lw_rss - 0.4]), frequencies=freqs,
    background_levels=background,
)
print(two.reference_levels.shape)               # (2, 7): mean level per location (Eq. 10)
print(np.round(two.sound_power_level, 1))       # [89.1 92.  93.  92.2 89.3 85.1 78.9]
print(round(two.sound_power_level_a, 1))        # 96.5 dB(A)
```

### How the measurement goes

![Plan of a corner of a workroom, with a hatched wall along the top and down the left side. In the middle stands the machine inside its dashed reference box, 2.2 m by 1.4 m, with an arrow from its upper side marked main emission. A dotted ring 1 m out from the box marks the directivity survey, taken first at 1.5 m height, whose range of ±4 dB makes the machine directional. The reference sound source sits on that emitting side, at least 0.5 m clear of the box. Four numbered microphone positions stand 1.5 m from the box, each tagged with its zone from Table 1 of the standard. Position 1, above the right-hand corner, is joined by one dashed line to the box and another to the reference source, 1.5 m and 1.6 m, equal within 10 %, which is the plus-or-minus zone; position 2, on the same side but nearer the source, is a minus; position 3, out to the left of the machine, is nearer the machine than the source, a plus; position 4, below the machine, has its line to the source cut by the machine, the screened zone where Annex B recommends a single position. Positions 1 and 2 are at least 2 m apart, and position 3 keeps at least 0.5 m from the wall. Captions under the plan ask for three or four positions, each in sight of every emitting area or screened from all of them, and name the four zones. On the right, one panel lists the three readings taken at every position with the same orientation: the machine running, the reference source for 30 s, and the background just before or after. A second panel shows a machine longer than the measurement distance, with reference source locations along both sides one measurement distance apart, and gives the three rules for several locations: an omnidirectional machine takes locations along the sides one measurement distance apart, a machine with distinct emitting areas one location per area, and an omnidirectional machine whose largest dimension does not exceed the measurement distance, where nothing can go on top, one location by each vertical side; with a single emitting side, as here, one location does. A box at the foot carries Equation 11, the sound power level as the calibrated power of the reference source minus its mean level plus the mean level of the machine, and the Annex A excess over the free field, at least 7 dB where the microphones stand. Three lines under it give the background correction by margin, the class 1 instruments and calibration, and the conditions for grade 2](https://docs.jmrp.io/phonometry/media/diagram_sound_power_in_situ.svg)

Use class 1 instruments and filters, and a class 1 calibrator on every
microphone before and after each series, discarding the series if the two
readings differ by more than 0.5 dB. Listen to the machine first: where the
sound of one component predominates, the geometric centre of that component
is the acoustic centre and the reference box is drawn just round that
component, down to the floor it stands on; where no component sounds more
than any other, leave out every component that clearly emits nothing and take
the geometric centre and the box of what is left. Then survey the
directivity 1 m from the reference box, normally 1.5 m up and at 2 m
intervals or less along a side: within ±2 dB the machine counts as
omnidirectional, and beyond ±7 dB the result stays at survey grade. Put the
reference source as close to the acoustic centre as you can: for a
directional machine, where it simulates the emission pattern, otherwise on
top, and only failing that alongside, avoiding positions closer than 0.5 m to
the reference box. One location normally does. Where the largest dimension of
the reference box is greater than the measurement distance, use several:
along the sides, one measurement distance apart, for an omnidirectional
machine, and one per area for a machine with clearly definable emission
areas. Where that dimension does not exceed the measurement distance and an
omnidirectional machine cannot take the source on top, use four locations,
one adjacent to each vertical side of the box. Place three or four
microphones round the machine, at least 2 m apart and 0.5 m from every
boundary, where Annex A gives $\Delta L_f \ge 7$ dB, seeking positions as far
from the source as from the box, within 10 %; where they cannot all be there,
take one nearer the box, one equally far and one or two nearer the source. At
each position, with the same orientation, read the machine, the reference
source for about 30 s and the background just before or after, in octave
bands from 125 Hz to 8 kHz; an impulsive machine takes at least five events.
Correct each position for background: above 15 dB nothing, 6 dB to 15 dB by
Eq. 7, below 6 dB 1.3 dB at most, and that band fails the requirement, which
the report must flag, and is an upper bound where only the machine's margin
fell short. Record what the aural examination found, the dimensions of the
reference box, the measurement distance, the positions, the source locations
and $\Delta L_f$, and report band and A-weighted levels to 0.1 dB with the
grade, $U$, its coverage factor and probability.

### `sound_power_in_situ()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `levels` | 2D array | dB | `(n, bands)` | Measured $L'_{pi(\mathrm{ST})}$, one row per microphone position, three or four positions (7.4.1) |
| `reference_levels` | 2D or 3D array | dB | `(n, bands)` or `(m, n, bands)` | The reference source at the same positions, one grid per location, corrected per its manufacturer for speed, temperature and pressure but not for background |
| `reference_sound_power_levels` | 1D or 2D array, or `ReferenceSourceCalibration` | dB | `(bands,)` or `(m, bands)` | Calibrated $L_{W(\mathrm{RSS})}$, per location when each was calibrated in its own similar position (Eq. 12); a [`ReferenceSourceCalibration`](https://docs.jmrp.io/phonometry/devices/emission/free-field-qualification/) is summed from its one-third octave bands into the octaves at `frequencies` |
| `frequencies` | 1D array | Hz | 63 Hz to 8 kHz octaves | Nominal octave mid-band frequencies of Table D.1; required. Clause 3.11 puts the general-purpose range at 125 Hz to 8 kHz; the 63 Hz row of Table D.1 carries footnote a, which allows it only where the test environment, the reference sound source and the instrumentation are satisfactory at that frequency |
| `background_levels` | 1D or 2D array | dB | `(bands,)` or `(n, bands)` | $L_{pi(\mathrm{B})}$; one spectrum serves every position. `None` warns and leaves `background_requirement_met` `False` in every band, since 7.5 measures it at each position and 8.1 needs the margin |
| `reference_background_levels` | 1D or 2D array | dB | same shapes | Background for the reference-source reading; `None` reuses `background_levels` (7.5) |
| `temperature_c` | float | °C | default `23.0` | Air temperature at the test, for $C_2$ |
| `static_pressure_kpa` | float | kPa | default `101.325` | Static pressure at the test, for $C_2$; see `static_pressure_from_altitude` |
| `conditions` | `GradeConditions` | | | The two conditions Table 2 reads together: `excess_levels`, the $\Delta L_{f\mathrm{A}}$ at each position `(n,)` in decibels (Annex A), and `directivity_range`, the half-width of the A-weighted directivity survey in decibels (7.2). Either one left out leaves the determination at survey grade |
| `sigma_omc_db` | float | dB | $\ge 0$ | Standard deviation of the operating and mounting conditions (9.2); `None` leaves the uncertainty `NaN` |
| `coverage_factor` | float | | default `2.0` | $k$ of Eq. 23; 1.6 for a one-sided comparison with a limit |

The function returns an `InSituSoundPowerResult`: `sound_power_level` (Eq. 11
or 12, at the conditions of the test), `mean_source_level` and
`mean_reference_level` (Eq. 8, 9), `reference_levels` per location (Eq. 10),
`reference_power_level`, `background_correction` per position and band,
`reference_background_correction` per location, position and band,
`background_requirement_met` and `upper_bound` per band, `c2`, `grade`, `sigma_r0`,
`sigma_omc_db`, `sigma_tot`, `expanded_uncertainty`, `coverage_factor`,
`sound_power_level_a` and `quantity`. `sound_power_level_at_reference_conditions` adds `c2` to
the level (section 3).

## 2. Impulsive sources: the sound energy level (Eq. 13 to 20)

A press stroke or a door slam has no steady power to report. Clause 8.4
measures the **single event level** $L_E$ at each position instead, either
one event at a time, at least five of them (clause 7.6), or once over a run
of $N$ successive events, and clause 8.5 turns the mean into a **sound energy
level** $L_J$ in dB re 1 pJ by the same comparison, with the reference source
still read time-averaged over 30 s. Measured one at a time, each event is
corrected for background with Eq. 14 (Eq. 7 with the event level in the
margin) and the corrected levels are energy-averaged into the mean single
event level of the position (Eq. 13, 15); measured once over $N$ events, the
level is corrected and reduced by $10 \log_{10} N$ to one event (Eq. 16, 17).
The per-position levels are energy-averaged over the positions (Eq. 18), and

$$
L_J = L_{W(\mathrm{RSS})} - \overline{L_{p(\mathrm{RSS})}} + \overline{L_{E(\mathrm{ST})}}
$$

(Eq. 19), or its several-location form (Eq. 20), which is Eq. 12 with the
event mean in the last term. `sound_energy_in_situ` takes the events as a
3D `(n, N, bands)` array for the one-at-a-time form or as a 2D `(n, bands)`
measurement with `n_events=N` for the other, and returns the same result type
with `quantity='energy'`, the level in `sound_energy_level` and the Annex D
total in `sound_energy_level_a`.

One line of Eq. 14 deserves a note. It subtracts the **time-averaged**
background level $L_{pi(\mathrm{B})}$ from a **time-integrated** event level,
and asks only that both be measured over the same integration time $T$. As
printed, the difference is a true signal-to-background margin for $T$ = 1 s;
for a longer $T$ the background holds $10 \log_{10}(T/T_0)$ dB more energy
over the event's interval than its time-averaged level says (clause 3.4,
NOTE 1), and the margin is overstated by that much. ISO 3741 and ISO 3744
print the same line for their single-event clauses, so it is the family's
convention and not a misprint of this part. The library applies Eq. 14 as
printed by default and offers `integration_time` to carry the background to
the event's interval first; the two agree at $T$ = 1 s.

```python
# The same room, a press beside the compressor: six strokes measured one at a
# time at the four positions, each integrated over 4 s, with the same
# reference source reading and the same floor.
strokes = np.array([
    [96.3, 98.1, 99.4, 98.8, 96.0, 92.1, 86.4],
    [95.1, 97.4, 98.7, 98.0, 95.3, 91.4, 85.6],
    [97.0, 98.9, 100.1, 99.5, 96.6, 92.8, 87.0],
    [95.8, 97.9, 99.0, 98.4, 95.8, 91.9, 86.0],
])
events = np.stack([strokes + d for d in (-0.3, 0.2, 0.0, 0.4, -0.2, 0.1)], axis=1)
energy = emission.sound_energy_in_situ(
    events, rss, lw_rss, frequencies=freqs,                 # (4 positions, 6 events, 7 bands)
    background_levels=background, integration_time=4.0,
    conditions=emission.GradeConditions(excess_levels=[8.2, 7.6, 8.9, 8.0], directivity_range=4.0), sigma_omc_db=2.0,
)
print(energy.quantity)                            # energy
print(np.round(energy.sound_energy_level, 1))     # [103.7 105.3 106.1 105.3 102.4  98.6  93. ]
print(round(energy.sound_energy_level_a, 1))      # 109.7 dB(A) re 1 pJ
print(round(energy.expanded_uncertainty, 1))      # 5.0 dB: grade 2 with sigma_omc = 2 dB
```

The 125 Hz band fails the background requirement here too, and for the
reason the steady determination gave: the reference source's own margin over
the floor is below 6 dB there, and the flag follows both sources, so it is no
upper bound either. The 5.0 dB is the standard's
own example in clause 9.5, reproduced because the inputs are the same:
grade 2, $\sigma_\mathrm{omc}$ = 2.0 dB, $k$ = 2.

### `sound_energy_in_situ()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `event_levels` | 3D or 2D array | dB | `(n, N, bands)` or `(n, bands)` | $L'_{Ei,q(\mathrm{ST})}$ per event, or $L'_{Ei,N(\mathrm{ST})}$ of one measurement over $N$ events |
| `n_events` | int | | $\ge 1$ | $N$ for the 2D form (Eq. 17); must be `None` with the 3D form. Clause 7.6 asks for at least five events, so fewer than five warns and the determination is nonconforming, on either form |
| `integration_time` | float | s | $> 0$ | $T$ of the event measurement; `None` applies Eq. 14 as printed |
| `reference_levels`, `reference_sound_power_levels`, `frequencies`, `background_levels`, `reference_background_levels`, `temperature_c`, `static_pressure_kpa`, `excess_levels`, `directivity_range`, `sigma_omc_db`, `coverage_factor` | | | | As in `sound_power_in_situ()` |

## 3. Grade, uncertainty and reference conditions

**Grade (Table 2).** Engineering grade 2 needs the A-weighted excess
$\Delta L_{f\mathrm{A}} \ge 7$ dB at every microphone position and a source
directivity range within ±7 dB from the survey of clause 7.2, taken 1 m from
the reference box at intervals of 2 m or less; either indicator failing, or
not determined at all, gives survey grade 3. The table pairs each grade with
a typical upper bound of the reproducibility of the method, **1.5 dB** for
grade 2 and **4.0 dB** for grade 3, valid for a relatively flat spectrum in
which the 250 Hz to 4 kHz octaves carry the A-weighted level; a source
dominated by bands below 500 Hz reproduces worse than that. The excess itself
is Annex A (Eq. A.1),

$$
\Delta L_f(r) = L_{p(\mathrm{RSS}),r} - L_{W(\mathrm{RSS})} + 11\ \mathrm{dB} + 20 \log_{10}\frac{r}{r_0},
\qquad r_0 = 1\ \mathrm{m},
$$

measured along a line of sight from the reference source at varying $r$,
and it is zero in a free field: `excess_sound_pressure_level` evaluates it
and broadcasts, so one calibrated power serves a whole traverse.

**Uncertainty (clause 9).** The standard deviation of reproducibility of the
method and the deviation of the operating and mounting conditions of the
source, $\sigma_\mathrm{omc}$, combine in quadrature (Eq. 22) and the
expanded uncertainty follows with the coverage factor (Eq. 23):

$$
\sigma_\mathrm{tot} = \sqrt{\sigma_{R0}^2 + \sigma_\mathrm{omc}^2},
\qquad U = k\,\sigma_\mathrm{tot},
$$

with $k$ = 2 for the two-sided 95 % interval the standard assumes, or 1.6
for a one-sided comparison with a limit value. $\sigma_\mathrm{omc}$ is the
user's number, from repeated determinations under the conditions of clause
9.2 and E.3; the NOTE of 9.2 puts it near 0.5 dB for a steady source, 2 dB
for one with material flow and 4 dB for stone breaking, metal cutting or a
press under load. The standard's own example (clause 9.5), grade 2 with
$\sigma_\mathrm{omc}$ = 2.0 dB and $k$ = 2, gives
$U = 2\sqrt{1.5^2 + 2^2}$ dB = 5 dB, which the energy example above
reproduces. Without a `sigma_omc_db` the result carries `sigma_r0` and leaves
`sigma_tot` and `expanded_uncertainty` `NaN` rather than reporting a method
uncertainty as if it were the whole.

**Reference conditions (Annex C).** Eq. 11 gives the level at the
meteorological conditions of the test. Annex C carries it to 101.325 kPa and
23.0 °C with the radiation-impedance correction

$$
C_2 = -10 \log_{10}\frac{p_\mathrm{s}}{p_{\mathrm{s},0}} + 15 \log_{10}\frac{273.15 + \theta}{\theta_\mathrm{ref}},
\qquad \theta_\mathrm{ref} = 296\ \mathrm{K},
$$

the same $C_2$ as ISO 3741 clause 9.1.4 (the library evaluates it through
that module), valid for a monopole and a mean value for other sources, and
estimates the static pressure from the altitude of the site when no barometer
was read (Eq. C.2): $p_\mathrm{s} = p_{\mathrm{s},0}\,(1 - a H_\mathrm{a})^b$
with $a$ = 2.2560 × 10⁻⁵ m⁻¹ and $b$ = 5.2553. The result exposes `c2` and
the properties `sound_power_level_at_reference_conditions` and `sound_energy_level_at_reference_conditions`
(Eq. C.1, C.3); the A-weighted total under reference conditions is
`sound_power_level_a + c2`, since the shift is the same in every band. One
detail of the annex is worth knowing: $\theta_\mathrm{ref}$ is printed as
296 K beside a reference temperature of 23.0 °C, which is 296.15 K, so at
exactly the reference conditions $C_2$ is +0.003 3 dB and not zero. ISO 3741
and ISO 3744 print the same 296 K, so it is the family's rounding and the
library keeps it.

```python
# A plant 640 m above sea level, at 27 degC, with no barometer on site.
ps = emission.static_pressure_from_altitude(640.0)
print(round(ps, 2))                                 # 93.87 kPa (Eq. C.2)
high = emission.sound_power_in_situ(
    st, rss, lw_rss, frequencies=freqs, background_levels=background,
    temperature_c=27.0, static_pressure_kpa=ps,
)
print(round(high.c2, 3))                            # 0.423 dB
print(round(float(high.sound_power_level[3]), 2), round(float(high.sound_power_level_at_reference_conditions[3]), 2))
# 91.76 at the test conditions, 92.18 under the reference conditions (1 kHz)

# Annex A along a line of sight from the reference source, A-weighted.
print(np.round(emission.excess_sound_pressure_level([81.0, 76.5, 73.8], 92.5, [1.5, 3.0, 6.0]), 2))
# [3.02 4.54 7.86]: reverberant enough for grade 2 only from about 6 m out
```

**A-weighted totals (Annex D).** $L_{W\mathrm{A}}$ and $L_{J\mathrm{A}}$ are the
energy sums of the band levels plus the Table D.1 corrections $C_k$, which
are −26.2, −16.1, −8.6, −3.2, 0.0, 1.2, 1.0 and −1.1 dB from 63 Hz to 8 kHz,
the ISO 3744 Annex E octave values digit for digit; the library reads them
from the shared table and requires every entry of `frequencies` to be one of
those eight nominal centres, distinct and in ascending order; the 63 Hz row
is for use only where the environment and the instrumentation are
satisfactory there (Table D.1, footnote a).

## What this guide covers

- **Covered.** The ISO 3747 comparison in situ (`sound_power_in_situ`): the per-position
  background correction of clause 8.1 with its 6 dB and 15 dB rules and the
  1.3 dB cap, the mean corrected levels of clause 8.2, the sound power level
  for one (Eq. 11) or several (Eq. 12) reference-source locations, the
  single-event levels of clause 8.4 in both forms and the sound energy level
  of clause 8.5 (`sound_energy_in_situ`), the Table 2 grade with its
  $\sigma_{R0}$, the clause 9 uncertainty (Eq. 22, 23), the Annex A excess of
  sound pressure level (`excess_sound_pressure_level`), the Annex C reference
  conditions with Eq. C.2 (`static_pressure_from_altitude`) and the Annex D
  A-weighted totals.

- **Not covered.** The Annex E uncertainty budget (Table E.2 and its sensitivity coefficients)
  is documented but not modelled: $\sigma_{R0}$ is the typical upper bound of
  Table 2 by grade, not a machine-specific value from a round robin (9.3.2) or
  from the model of 9.3.3. The zoning of Table 1, the directivity survey of
  clause 7.2 and the placement rules of clause 7.3 are the operator's
  decisions, made before the levels exist; the library takes the levels and the
  two indicators the grade needs. The reference source's own corrections for
  speed, temperature and static pressure are its manufacturer's, applied before
  the levels arrive. The other in situ routes are their own guides:
  [Sound Power by Pressure Methods](https://docs.jmrp.io/phonometry/devices/emission/sound-power-pressure/)
  for the enveloping surface, [Sound Power by Intensity Scanning](https://docs.jmrp.io/phonometry/devices/emission/sound-power-intensity/)
  for the probe.

## See also

- [Sound Power](https://docs.jmrp.io/phonometry/devices/emission/sound-power/): choosing among the
  determination routes, the accuracy grades and the ISO 4871 noise-emission
  declaration.
- [Sound Power in the Reverberation Room](https://docs.jmrp.io/phonometry/devices/emission/sound-power-reverberation/):
  the precision comparison of ISO 3741 in a qualified room, whose $C_2$ this
  guide shares.
- [Sound Power by Pressure Methods (ISO 3744 / ISO 3746 / ISO 3745)](https://docs.jmrp.io/phonometry/devices/emission/sound-power-pressure/):
  the enveloping surface for a source that can be measured in its direct field.
- [Sound Power by Intensity Scanning (ISO 9614)](https://docs.jmrp.io/phonometry/devices/emission/sound-power-intensity/):
  the routes that tolerate steady background noise without a reference source.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): energy averaging, the single
  event level and the A-weighting behind $L_{W\mathrm{A}}$.
- API reference: [`emission`: sound power in situ](https://docs.jmrp.io/phonometry/reference/api/power/sound-power-in-situ/).

## References

- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering/survey methods for use in situ in a reverberant environment*](https://www.iso.org/standard/46426.html) (ISO 3747:2010).
  The comparison method of this guide: the background correction of clause 8.1, the mean levels and the sound power and sound energy levels of clauses 8.2 to 8.5, the Table 2 grades, the clause 9 uncertainty and Annexes A, C and D.
- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for reverberation test rooms*](https://www.iso.org/standard/52053.html) (ISO 3741:2010).
  The precision comparison method of a qualified room, whose Eq. 21 is Eq. 11 of this guide plus the same radiation-impedance correction C2 (clause 9.1.4), reused here for Annex C.