# Swept-sine distortion and phase utilities

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/devices/electroacoustics/swept-sine-distortion/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-18
Updated: 2026-11-16T21:36:13Z
Standards: 108th AES Convention, Paris, preprint 5093
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Harmonic-distortion separation from one exponential sweep (Farina, Novak): THD against frequency, minimum phase, group delay and excess phase.

---

A single exponential sine sweep characterises the linear response and
every harmonic distortion order of a weakly nonlinear system at once.
After deconvolution, the distortion products of order $n$ pack
into separate impulse responses that *precede* the linear response by the
fixed advance (Farina 2000)

$$
\Delta t_n = T\,\frac{\ln n}{\ln (f_2/f_1)} = L \ln n ,
\qquad L = \frac{T}{\ln(f_2/f_1)} ,
$$

so windowing each arrival yields the **higher harmonic frequency responses**
$H_1(f), H_2(f), \dots, H_N(f)$ and, from them, the total harmonic distortion as
a function of the excitation frequency with one sweep instead of a
tone-by-tone stepping. This page covers that separation in
`phonometry.electroacoustics`, with the phase-coherent **synchronized
sweep** of Novak, Lotton & Simon (2015) as the default, and the companion
**phase utilities** in `phonometry.signals`: minimum phase from $|H|$,
group delay and excess phase.

## 1. One sweep, every harmonic

For an exponential sweep the instantaneous frequency rises as
$f(t) = f_1 \mathrm{e}^{t/L}$, so the moment the excitation passes $f$, the n-th
harmonic distortion product appears at $n f$: exactly where the sweep
itself will be $L\ln(n)$ seconds later. Deconvolving the recording against
the sweep therefore time-compresses each order into its own impulse
response, $L\ln(n)$ *before* the linear one. `swept_sine_distortion`
windows each arrival (with the exact fractional-sample alignment), Fourier
transforms it into $H_n(f)$, and reads the distortion of order $n$ at
excitation frequency $f$ from $|H_n(n f)|$:

$$
\mathrm{THD}(f) =
\frac{\sqrt{\sum_{n\ge 2} |H_n(nf)|^2}}{|H_1(f)|} .
$$

The chain is exactly the sketch below: play the sweep, record, convolve with
the inverse filter, and the harmonics land ahead of the linear response by
their fixed advances.

![Swept-sine distortion measurement chain: an exponential sweep from 20 Hz to 6 kHz in T equal to 4 s drives the weakly nonlinear device under test, the recording is deconvolved with the time-reversed inverse filter with its plus 6 dB per octave tilt, and on the resulting time axis the linear impulse response h1 sits at t equal to zero while the second, third and fourth harmonic responses appear as smaller pre-arrivals in their own dashed windows, advanced by L times ln n, 0.49 s for h2 and 0.77 s for h3 with L equal to 0.70 s](https://docs.jmrp.io/phonometry/media/diagram_swept_sine.svg)

*The advances are fixed by the sweep alone, $L = T/\ln(f_2/f_1) = 0.70$ s
here, and not by the device, which is why the same windows work for any
weakly non-linear system and why lengthening the sweep is what buys
separation.*

The sketch is the end state. The clip shows how the recording gets there:
while the sweep plays, the response draws one ridge per order on the
time-frequency plane, straight and parallel on a logarithmic frequency axis
and each $L\ln n$ ahead of the sweep, and the inverse filter then stands them
up into separate arrivals.

**Video:** [The harmonic ridges of a swept-sine recording and their collapse](https://docs.jmrp.io/phonometry/media/anim_sweep_harmonics.webm): An exponential sweep from 20 Hz to 6 kHz plays for 4 s while the spectrogram of the response builds on a logarithmic frequency axis: the fundamental ridge and, fainter and parallel to it, the ridges at twice, three and four times the frequency. Arrows then measure how far ahead of the sweep each harmonic ridge runs, 0.49 s, 0.77 s and 0.97 s. The inverse filter moves every frequency back by the time the sweep took to reach it, the four ridges stand up into vertical lines, and beside them the impulse response of each order appears 0.49 s, 0.77 s and 0.97 s before the linear one.

*The recording is the sweep of this section through the same memoryless
polynomial with a fourth-order term added, so that a fourth ridge exists. The
collapse is drawn as the shift the filter's group delay, $L\ln(f/f_1)$, applies
to each row of the recorded map; the arrivals on the right are the windowed
responses `swept_sine_distortion` returns, as envelopes in decibels.*

```python
import numpy as np
from phonometry import electroacoustics

fs, f1, f2, seconds = 48000, 20.0, 6000.0, 4.0
x = electroacoustics.synchronized_sweep_signal(fs, f1, f2, seconds)   # play this...
# ... record the device response into `y` (include the decay tail) ...
y = x + 0.12 * x**2 + 0.08 * x**3     # a memoryless cubic stands in for the recording
res = electroacoustics.swept_sine_distortion(y, fs, f1=f1, f2=f2, duration_s=seconds, n_harmonics=3)

res.harmonic_responses    # complex H1..H3 on res.frequencies
res.thd_ratio, res.thd_frequencies
res.distortion_ratios     # |Hn(n f)| / |H1(f)| per order
res.plot()                # |Hn| magnitudes + THD(f)
```

### 1.1 Playing and recording it

A THD(f) curve is a property of the device **at one drive level**, so it has
to be published with that level and, for an acoustic measurement, with the
sound pressure level it produced at the microphone. The same loudspeaker
measured 6 dB louder returns a curve several decibels higher *and differently
shaped*, because the mechanisms that dominate change with excursion. Choose
the level between two walls: high enough that the harmonics stand clear of the
background, because the deconvolution's processing gain helps the linear
response far more than it helps the pre-arrivals, and low enough that neither
the device nor any converter in the chain clips: a clipped record manufactures
exactly the odd-order harmonics being measured, in every window. Note also that
a sweep has a much lower crest factor than a tone burst, so at equal peak
amplitude it delivers more energy and pushes a device harder than a tone test
at the same nominal level.

Four things must be set before the first take:

```python
import numpy as np

# `synchronized_sweep_signal` and `swept_sine_distortion` as imported above.
x = electroacoustics.synchronized_sweep_signal(fs, f1, f2, seconds, amplitude=0.5, fade=0.02)
# ... play x, record y, and keep recording until the decay has died ...
y = x + 0.12 * x**2 + 0.08 * x**3     # the same cubic, now at the level played
res = electroacoustics.swept_sine_distortion(y, fs, f1=f1, f2=f2, duration_s=seconds, n_harmonics=3,
                                             amplitude=0.5, fade=0.02)
```

- **`amplitude`** is the reference the returned $H_1$ and every ratio are
  computed against, so it must be the level actually played, and the *same*
  value has to reach both calls: the analysis defaults to 1.0, so a sweep
  generated at 0.5 and analysed at the default returns a gain 6 dB low.
- **`fade`** applies a short half-Hann taper at both ends. It is 0 by default
  because the analysis is exact on the unfaded sweep, but an unfaded sweep
  starts and ends on a full-amplitude discontinuity that clicks through a real
  amplifier and loudspeaker and smears energy across the whole harmonic time
  axis. The same value must be passed to the analysis, or the deconvolution is
  mismatched; 20 ms reshapes only the extreme band edges.
- **Clipping.** Check every stage, not just the converter: the point of the
  measurement is destroyed by any element that clips before the one under test.
- **The tail.** Record the sweep *plus* its full decay, or the harmonic
  pre-arrivals wrap round the circular deconvolution into the end of the linear
  response.

Two failure modes are silent rather than obvious. The method assumes the system
does not change during the sweep, so a running fan, a person moving, a warming
voice coil or a drifting room temperature decorrelates the later part of the
sweep from the earlier part and shows up as a raised noise floor around the
harmonic arrivals rather than as an evident failure, which is why long
measurements are averaged rather than lengthened indefinitely. And any impulsive
event in the recording is spread by the deconvolution across the whole time
axis, landing inside the harmonic windows where it is read as distortion: one
loud click can invent several percent of THD, so repeat the measurement rather
than trying to gate it out. Finally, the residual noise floor of the
deconvolution is the floor of the THD(f) curve: a 60 dB signal-to-noise
capture cannot show a 0.05 % harmonic however the windows are placed, so
report the measured noise floor beside the curve.

![Two benches for a sweep measurement: panel (a) an audio interface driving an electrical device under test with a second interface channel wired straight back from the output as a loopback reference that fixes t equal to zero; panel (b) a loudspeaker and a measurement microphone both 1.20 m over a hard floor and 1.00 m apart, with the reflected path of 2.60 m dashed and the resulting reflection-free time of 4.7 ms stated; below both, the sweep's own time axis with the linear arrival at t equal to zero, the second and third harmonic pre-arrivals at minus 0.49 and minus 0.77 seconds, the per-order window of 8192 samples and the closest arrival spacing L ln(3/2) equal to 0.28 s](https://docs.jmrp.io/phonometry/media/diagram_sweep_bench.svg)

![Total harmonic distortion and the second and third harmonic ratios of a cubic polynomial followed by a 3 kHz low-pass, against excitation frequency: each order sits exactly on its Chebyshev level at low frequency and rolls off where its own product crosses the filter corner](https://docs.jmrp.io/phonometry/media/swept_sine_thd.svg)

*The flat low-frequency plateaus are the Chebyshev levels $(a_2/2)/H_1$ and
$(a_3/4)/H_1$ of the memoryless polynomial, and each order bends down where its
own product $nf$ crosses the 3 kHz post-filter, so the knees are at 1.5 kHz
for $d_2$ and 1 kHz for $d_3$, on the excitation axis. That is the same oracle
the conformance tests pin.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import signal as sp_signal
from phonometry import electroacoustics

fs, f1, f2, seconds = 48000, 20.0, 6000.0, 4.0
a2, a3 = 0.12, 0.08
x = electroacoustics.synchronized_sweep_signal(fs, f1, f2, seconds)
b, a = sp_signal.butter(2, 3000.0, fs=fs)             # 3 kHz post-filter
y = sp_signal.lfilter(b, a, x + a2 * x**2 + a3 * x**3)
res = electroacoustics.swept_sine_distortion(y, fs, f1=f1, f2=f2, duration_s=seconds, n_harmonics=3)

h1 = 1.0 + 3.0 * a3 / 4.0                              # Chebyshev gain
fig, ax = plt.subplots(figsize=(10, 6))
ax.loglog(res.thd_frequencies, 100.0 * res.thd_ratio, label="Total THD(f)")
ax.loglog(res.thd_frequencies, 100.0 * res.distortion_ratios[0],
          ls="--", label="2nd harmonic d2(f)")
ax.loglog(res.thd_frequencies, 100.0 * res.distortion_ratios[1],
          ls="--", label="3rd harmonic d3(f)")
ax.axhline(100.0 * (a2 / 2.0) / h1, ls=":",
           label="Chebyshev asymptote (a2/2)/H1")
ax.axhline(100.0 * (a3 / 4.0) / h1, ls=":",
           label="Chebyshev asymptote (a3/4)/H1")
ax.set_xlabel("Excitation frequency [Hz]")
ax.set_ylabel("Distortion re fundamental [%]")
ax.legend()
plt.show()
```

The oracle behind the implementation is the memoryless polynomial: driving
$y = x + a_2 x^2 + a_3 x^3$ with a unit sweep must return, by the Chebyshev
identities, $|H_1| = 1 + 3a_3/4$, $|H_2| = a_2/2$ (phase $-\pi/2$), $|H_3| = a_3/4$
(phase $\pi$) and $\mathrm{THD} = \sqrt{(a_2/2)^2 + (a_3/4)^2}/(1 + 3a_3/4)$. The test and
conformance suites pin all four, and the same THD measured tone by tone
with `phonometry.thd` agrees to 0.1 %.

What the method exists to produce, though, is not the scalar ratios (a stepped
tone sweep gives those too), but the **set of harmonic transfer functions**.
Each $H_n$ is a full frequency response over its own band $[n f_1, n f_2]$:

![The magnitudes of the three separated harmonic responses of a cubic polynomial followed by a 3 kHz low-pass, each drawn over its own band: H1 from 20 Hz to 6 kHz, H2 from 40 Hz to 12 kHz and H3 from 60 Hz to 18 kHz, each sitting on its dotted Chebyshev level at low frequency and rolling off at the same 3 kHz post-filter corner](https://docs.jmrp.io/phonometry/media/swept_sine_harmonic_responses.svg)

*Each order is a response, not a number, and here they are plotted against the
frequency of the harmonic itself: all three roll off at the same 3 kHz, because
the post-filter acts on the product and not on the excitation. The dotted lines
are the Chebyshev levels. `res.plot()` draws these magnitudes together with the
THD(f) panel above.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import signal as sp_signal

# `swept_sine_distortion` and `synchronized_sweep_signal` as imported above.
fs, f1, f2, seconds = 48000, 20.0, 6000.0, 4.0
a2, a3 = 0.12, 0.08
x = electroacoustics.synchronized_sweep_signal(fs, f1, f2, seconds)
b, a = sp_signal.butter(2, 3000.0, fs=fs)
y = sp_signal.lfilter(b, a, x + a2 * x**2 + a3 * x**3)
res = electroacoustics.swept_sine_distortion(y, fs, f1=f1, f2=f2, duration_s=seconds, n_harmonics=3)

for k in range(3):
    mag = np.abs(np.asarray(res.harmonic_responses[k]))
    plt.semilogx(res.frequencies, 20 * np.log10(np.maximum(mag, 1e-9)))
plt.show()
```

**Reading a real device.** On a measured driver the curve has a shape worth
recognising: distortion rising steeply below the fundamental resonance, where
excursion grows as the response falls; a local peak wherever a resonance is
being driven hard; and a floor of a fraction of a percent through the mid band
at moderate drive. Separating the orders is what makes the curve diagnostic: a
dominant **second** harmonic is asymmetry: a voice coil not centred in the gap,
a suspension stiffer in one direction than the other. A dominant
**third** is symmetric limiting, the suspension or the magnetic gap running out
at both extremes, and the two call for different fixes. For scale, below about
1 % through the mid band is unremarkable for a direct radiator at conversational
levels, 10 % is the conventional marker for the excursion limit that defines a
driver's usable low-frequency end, and any amplifier reaching 1 % below clipping
is broken. Remember that the abscissa is the *excitation* frequency: a feature
at 100 Hz on the $d_2$ trace is energy radiated at 200 Hz, which is where it
will be heard.

## 2. The synchronized sweep (Novak et al. 2015)

Windowing separates the harmonic *magnitudes* with any exponential sweep,
but the *phases* of $H_2 \dots H_N$ are only meaningful if delaying the sweep by
$L\ln(n)$ is exactly equivalent to generating its n-th harmonic. That holds
only for

$$
x(t) = \sin\!\big[2\pi f_1 L\, \mathrm{e}^{t/L}\big],
\qquad
L = \frac{1}{f_1}\,\mathrm{round}\!\Big(\frac{f_1\,\tilde T}{\ln(f_2/f_1)}\Big),
$$

the **synchronized swept-sine**: the rounding makes $f_1 L$ an integer, so
the sweep starts at zero phase and every harmonic copy lines up.
`synchronized_sweep_signal` generates it (the duration is quantized
slightly; when $f_2/f_1$ is an integer the sweep also ends at zero phase),
and `swept_sine_distortion(..., method="synchronized")`, the default,
deconvolves with the closed-form spectrum of the inverse filter,

$$
\tilde X(f) = 2\sqrt{f/L}\;
\mathrm{e}^{-j 2\pi f L\,(1 - \ln(f/f_1)) + j\pi/4},
$$

rather than an FFT of the signal. Besides being exact, the analytic
deconvolution extends the usable band of each $H_n$ to $[n f_1, n f_2]$
(Novak et al., Fig. 6): the second harmonic of a 6 kHz sweep is measured
up to 12 kHz.

Two practical notes from the paper are built in: the recording mean is
subtracted by default (`remove_dc=True`; a DC offset otherwise leaks a
scaled inverse filter into the impulse response), and the non-integer part
of each arrival $L\ln(n) f_\mathrm{s}$ is removed in the frequency domain, so the
harmonic phases carry no residual sub-sample skew.

## 3. Analysing classical exponential-sweep (ESS) recordings (`method="farina"`)

Recordings made with the plain **exponential sine sweep (ESS)** of
`phonometry.sweep_signal` (the ISO 18233 excitation used by
[`impulse_response`](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/)) are analysed with
`method="farina"`: the same windowing over the time-reversed,
amplitude-compensated inverse filter of Farina (2000). The harmonic
**magnitudes** and the THD are correct (the Chebyshev oracle passes
identically), but the sweep's `-1` phase term breaks the time-shift
equivalence, so the phases of $H_2 \dots H_N$ depend on the excitation and should
be ignored; the band of every $H_n$ is also capped at $f_2$ by the inverse
filter.

```python
from phonometry import electroacoustics, room

x = room.sweep_signal(fs, f1, f2, seconds)          # the ISO 18233 ESS
y = x + 0.12 * x**2 + 0.08 * x**3                   # the same cubic, recorded from the ESS
res = electroacoustics.swept_sine_distortion(y, fs, f1=f1, f2=f2, duration_s=seconds, method="farina")
res.plot()   # same |Hn| + THD(f) panels as the synchronized method (needs matplotlib)
```

The result is the same plottable `SweptSineDistortionResult` as the
synchronized method, so the `|Hn|` and `THD(f)` panels of the section-1
figure read identically; only the harmonic phases (and the top of each
order's band) differ between the two methods. Both differences are visible on
one recording:

![The second harmonic response of one recording of a memoryless cubic, analysed twice: in the upper panel the magnitudes coincide on the Chebyshev level a2 over 2 but the Farina curve stops dead at f2 equal to 6 kHz while the synchronized curve continues to 2 f2 equal to 12 kHz; in the lower panel the synchronized phase sits on the true value of minus pi over two at every frequency while the Farina phase drifts away above about 1 kHz](https://docs.jmrp.io/phonometry/media/swept_sine_methods.svg)

*Same recording, same magnitudes, two differences. The synchronized
deconvolution measures $H_2$ up to $2f_2$; the Farina inverse filter stops it
at $f_2$. And on a device whose true $H_2$ phase is exactly $-\pi/2$ at every
frequency (the memoryless cubic of the oracle), only the synchronized phase
reproduces it, which is why `method="farina"` returns phases that must be
discarded rather than read.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

# `synchronized_sweep_signal` and `swept_sine_distortion` as imported above.
x = electroacoustics.synchronized_sweep_signal(48000, 20.0, 6000.0, 4.0)
y = x + 0.12 * x**2 + 0.08 * x**3            # the memoryless oracle
actual = len(x) / 48000                       # the generator quantizes T
for method in ("synchronized", "farina"):
    res = electroacoustics.swept_sine_distortion(y, 48000, f1=20.0, f2=6000.0, duration_s=actual,
                                                 n_harmonics=3, method=method)
    plt.semilogx(res.frequencies,
                 np.unwrap(np.angle(np.asarray(res.harmonic_responses[1]))))
plt.show()
```

## 4. Sizing the sweep

Before recording anything, three numbers have to agree: the sweep duration $T$,
the number of harmonic orders $N$ and the top frequency $f_2$. The rules below
govern **both** methods.

- **The window against the arrival spacing.** The closest pair of arrivals is
  spaced $L\ln\bigl(N/(N-1)\bigr)$ seconds apart, so the per-order window
  (`ir_length`, default the largest power of two that fits, capped at 8192
  samples) must not exceed it. Lengthen the sweep or lower `n_harmonics` for a
  reverberant system whose tail needs a longer window.
- **The Nyquist ceiling.** Keep $N f_2$ below $f_\mathrm{s}/2$: distortion products above
  it fold back in any real recording and are then counted at the wrong
  frequency.
- **The amplitude reference.** The analysis is referenced to the excitation
  `amplitude`, so $H_1$ is the linear gain and the THD is level-referenced
  exactly as driven.

Worked for the sweep this page uses: $f_1 = 20$ Hz, $f_2 = 6$ kHz, $T = 4$ s
give $L = T/\ln(f_2/f_1) = 0.70$ s, so the $H_3$-to-$H_2$ spacing is
$0.70\ln(3/2) = 0.28$ s and the 8192-sample default window (0.17 s at 48 kHz)
fits inside it with room to spare. At $N = 3$ and $f_2 = 6$ kHz the ceiling
$N f_2 = 18$ kHz is comfortably below the 24 kHz Nyquist frequency.

## 5. Phase utilities: minimum phase, group delay, excess phase

For a causal, stable, minimum-phase system the log-magnitude and phase of
the frequency response are a Hilbert-transform pair (Bendat & Piersol,
Sec. 13.1.4): the phase is fully determined by $|H(f)|$. The
`phonometry.signals` utilities compute that reconstruction with the real
cepstrum and decompose any measured response into its invertible and
all-pass parts:

```python
import numpy as np
from scipy import signal as sp_signal
from phonometry import signals

gain_a = 10.0 ** (6.0 / 40.0)          # the measured device: a +6 dB peaking EQ
w0 = 2.0 * np.pi * 1000.0 / fs         # at 1 kHz, Q = 1, through a 2.5 ms latency
alpha = np.sin(w0) / 2.0
b = np.array([1 + alpha * gain_a, -2 * np.cos(w0), 1 - alpha * gain_a])
a = np.array([1 + alpha / gain_a, -2 * np.cos(w0), 1 - alpha / gain_a])
imp = np.zeros(16384)
imp[int(0.0025 * fs)] = 1.0
ir = sp_signal.lfilter(b / a[0], a / a[0], imp)

H = np.fft.rfft(ir)                    # one-sided response, DC..Nyquist
h_min = signals.min_phase(np.abs(H))       # phase from the magnitude alone
tau_g = signals.group_delay(H, fs)             # -(1/2pi) dphi/df, seconds
phi_x = signals.excess_phase(H)                # unwrap(arg H) - phi_min

res = signals.phase_decomposition(H, fs)       # everything on one axis
res.excess_group_delay                 # the all-pass part, in seconds
res.plot()                             # magnitude, phases, group delays
```

![Three stacked panels of the minimum-phase / all-pass decomposition of a +6 dB peaking equalizer measured through a 2.5 ms latency: the magnitude bump at 1 kHz, the measured phase diving with frequency while the minimum phase stays small and the excess phase carries the linear delay ramp, and the group delays where the excess group delay reads a flat 2.5 ms](https://docs.jmrp.io/phonometry/media/phase_decomposition.svg)

*A +6 dB peaking equalizer measured through a 2.5 ms processing latency: the
minimum-phase part carries only the small phase wiggle an equalizer could
invert, the excess phase is the pure $-2\pi f t_0$ ramp of the delay, and the
excess group delay reads the latency directly as a flat 2.5 ms line.*

**In an acoustic measurement that flat part is not latency, it is distance.**
The time of flight from loudspeaker to microphone is about 2.9 ms per metre, so
a response measured at 1 m carries a 2.9 ms excess group delay that has nothing
to do with the electronics, and a reader who reads it as processing latency
will try to compensate a delay that does not exist. Remove it first: trim the
impulse response to its arrival, or subtract the known distance, because
nothing else in the excess phase can be interpreted until it is gone. What
remains after the removal is the part that matters: an all-pass residue no
equalizer can invert, produced by genuinely non-minimum-phase behaviour such as
a strong reflection arriving later than the direct sound, or a crossover whose
drivers' acoustic centres are not aligned. That is the design question
`phase_decomposition` is actually asked in loudspeaker and room correction: a
response that is minimum phase once the delay is removed can be corrected in
magnitude and phase together by a single filter; one that is not, cannot.

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy import signal as sp_signal
from phonometry import signals

fs = 48000.0
delay = int(0.0025 * fs)                      # a 2.5 ms processing latency
gain_a = 10.0 ** (6.0 / 40.0)                 # +6 dB peaking EQ at 1 kHz, Q = 1
w0 = 2.0 * np.pi * 1000.0 / fs
alpha = np.sin(w0) / 2.0
b = np.array([1 + alpha * gain_a, -2 * np.cos(w0), 1 - alpha * gain_a])
a = np.array([1 + alpha / gain_a, -2 * np.cos(w0), 1 - alpha / gain_a])
imp = np.zeros(16384)
imp[delay] = 1.0
ir = sp_signal.lfilter(b / a[0], a / a[0], imp)

res = signals.phase_decomposition(np.fft.rfft(ir), fs)
res.plot()   # |H|, the three phases and the group delays
plt.show()
```

The decomposition $H = H_\text{min} H_\text{ap}$ splits what an equalizer can invert
($H_\text{min}$, minimum phase, causal and causally invertible) from what it never
can ($H_\text{ap}$, the all-pass excess: latency plus non-minimum-phase zeros such
as reflections). The excess phase is $0$ for a minimum-phase response and
exactly $-2\pi f t_0$ for a pure latency $t_0$; its group delay reads the
latency in seconds.

Numerical contract, pinned by the tests: on a strictly minimum-phase biquad
sampled on a dense grid the reconstructed phase matches the true phase to
better than $10^{-12}$ rad; the group delay of a first-order allpass matches
the closed form $(1-a^2)/(1+2a\cos\omega+a^2)$ to $10^{-5}$ samples; the excess group
delay of a delayed biquad returns the delay to $10^{-6}$ samples. The
precautions are documented with the API: the response must be sampled
uniformly from DC to Nyquist inclusive (the `rfft` layout) and densely
enough that the underlying impulse response fits the implied record;
magnitude zeros (band-pass edges, notch bottoms) are floored and are not
representable by a minimum-phase system; the `oversample` factor
(trigonometric interpolation of the magnitude before the cepstrum)
mitigates the cepstral aliasing that near-circle zeros cause on coarse
grids.

## Relation to other tools

- [`impulse_response`](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) recovers the
  *linear* IR from the same sweep recording and simply discards the
  negative-time distortion products; `swept_sine_distortion` is the tool
  that reads them.
- [`thd` / `harmonic_analysis`](https://docs.jmrp.io/phonometry/devices/electroacoustics/electroacoustics/)
  measure distortion from a steady tone at one frequency; the sweep
  separator returns the same ratios as a continuous function of frequency,
  from one measurement. Speed is the least of the reasons to prefer it.
  Deconvolving a sweep of duration $T$ concentrates the whole excitation into
  one impulse, so the signal-to-noise ratio of the result exceeds that of the
  raw recording by roughly $10\log_{10}$ of the time-bandwidth product, which
  is how a sweep measures a quiet device in a room a stepped tone could not
  work in. And the separation is *in time, not in frequency*: no notch filter
  is applied and no bin has to be declared a harmonic, which is what keeps
  THD(f) meaningful where a device's own harmonics fall outside its passband.
  The counterpart is that a reverberant tail outlasting the spacing
  $L\ln(N/(N-1))$ contaminates the neighbouring order, which is what the sizing
  rules of section 4 exist to prevent.
- The phase utilities operate on any one-sided *complex* response: an
  `rfft` of a measured IR, or the `response` of a
  [`transfer_function`](https://docs.jmrp.io/phonometry/devices/electroacoustics/electroacoustics/) estimate on a
  uniform grid. `min_phase` alone also accepts a plain magnitude
  array, e.g. a design target for equalization.

## What this guide covers

- **Covered.** Farina's exponential-sweep deconvolution (AES preprint 5093, 2000) and the
  phase-coherent synchronized swept-sine of Novak, Lotton & Simon (2015): the
  harmonic separation, the closed-form inverse-filter spectrum and the
  fractional-sample de-skewing, implemented by `swept_sine_distortion` and
  `synchronized_sweep_signal`. The acquisition conditions the result depends on:
  the drive level and its `amplitude` reference, the `fade` that must reach both
  calls, the clipping and tail requirements, the time-variance and
  impulsive-noise failure modes, and the sizing rules that relate $T$, $N$ and
  $f_2$. The phase utilities `min_phase`, `group_delay`, `excess_phase` and
  `phase_decomposition` implement the Hilbert-transform relation of Bendat &
  Piersol Section 13.1.4 through the real cepstrum.

- **Not covered.** Intermodulation and dynamic intermodulation distortion (IEC 60268-3, clauses
  14.12.7-10) are measured from steady tones on the
  [electroacoustics](https://docs.jmrp.io/phonometry/devices/electroacoustics/electroacoustics/)
  page, not from a sweep; this page separates harmonic orders only. Müller &
  Massarani's sweep monograph is cited for background practice (fades,
  inverse-filter technique), not for a specific implemented formula. With
  `method="farina"`, the harmonic phases of $H_2 \dots H_N$ are returned but
  should be ignored: the plain exponential sweep breaks the time-shift/harmonic
  equivalence the synchronized method relies on. Nothing here checks the
  acquisition conditions of section 1.1 either: the functions take the arrays
  they are given, so the drive level, the absence of clipping and the length of
  the tail are the operator's to keep and to report.

## See also

- [Electroacoustics](https://docs.jmrp.io/phonometry/devices/electroacoustics/electroacoustics/): the
  steady-tone $\mathrm{THD}$, THD+N and intermodulation set of IEC 60268-3
  that this sweep complements, and the operating point they are all defined at.
- [Loudspeaker Characterisation (IEC 60268-5)](https://docs.jmrp.io/phonometry/devices/electroacoustics/loudspeakers/):
  the THD(f) curve produced here is the distortion panel of that
  rated-characteristics report.
- [Room acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): `impulse_response`,
  which is the linear half of the same recording.
- API reference: [`electroacoustics.swept_sine`](https://docs.jmrp.io/phonometry/reference/api/electroacoustics/swept-sine/)
  and [`signals.phase`](https://docs.jmrp.io/phonometry/reference/api/signals/phase/).

## References

- **Bendat, J. S., & Piersol, A. G. (2010).** *Random data: Analysis and measurement procedures* (4th ed.). Wiley. https://doi.org/10.1002/9781118032428
  Section 13.1.4: the Hilbert-transform relation between log-magnitude and phase behind the minimum-phase reconstruction. ISBN 978-0-470-24877-5.
- **Farina, A. (2000).** [*Simultaneous measurement of impulse response and distortion with a swept-sine technique*](https://www.aes.org/e-lib/browse.cfm?elib=10211) (108th AES Convention, Paris, preprint 5093).
  The exponential-sweep deconvolution and the L·ln(n) packing of each distortion order ahead of the linear impulse response.
- **Müller, S., & Massarani, P. (2001).** [Transfer-function measurement with sweeps](https://aes.org/publications/elibrary-page/?id=10189). *Journal of the Audio Engineering Society*, *49*(6), 443-471.
  The sweep-measurement monograph behind the practice notes: inverse filters, fades and the rejection of distortion from the linear impulse response.
- **Novak, A., Lotton, P., & Simon, L. (2015).** Synchronized swept-sine: Theory, application and implementation. *Journal of the Audio Engineering Society*, *63*(10), 786-798. https://doi.org/10.17743/jaes.2015.0071
  The synchronization condition that makes harmonic phases system properties, the closed-form inverse-filter spectrum used for the deconvolution and the fractional-sample separation.