# Spatial Sound Decay in Workrooms

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/rooms/workroom-sound-decay/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/rooms/workroom-sound-decay/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-15
Updated: 2026-11-16T21:36:14Z
Standards: ISO 14257:2001; ISO 11690-3:1998
Verified: 25 conformance checks (ISO 14257:2001; ISO 11690-3:1998) https://docs.jmrp.io/phonometry/reference/conformance/#spatial-sound-decay-and-prediction-in-workrooms
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Spatial sound decay in workrooms: the ISO 14257 curve, its descriptors DL2 and DLf, the Annex B correction and ISO 11690-3 prediction.

---

A reverberation time says what a room does to a decay in time. It says very
little about what a factory hall does to a worker standing 20 m from a press.
The question there is a question about **distance**: how much quieter does it
get as you walk away, and how much louder is it than open air would be?

ISO 14257 answers both with one measurement. A calibrated source stands where a
machine would, a microphone walks away from it along a straight path, and the
curve of level against distance is the room's own signature.

![Three panels. Left: the sound distribution value against distance from two to forty-eight metres, in three octave bands, each curve well above the dashed free-field line that falls six decibels per doubling, with the gap between the one-kilohertz curve and that line shaded. Middle: bar chart of the rate of spatial decay for three bands in the near, middle and far ranges, all of them under the dotted six-decibel free-field line, with the two-to-five-decibel band the design standard expects shaded across the middle. Right: the Annex B correction against distance for two bands, largest close to the source at about two decibels at one kilohertz and dying away with distance, while the four-kilohertz curve stays near zero until the last position](https://docs.jmrp.io/phonometry/media/workroom_spatial_decay.svg)

*The curve, what it yields range by range, and the correction that takes the
source's own directivity back out. The data is the shipyard hall of Annex C.*

## 1. The curve: a level referred to the power that made it

A level on its own cannot be compared between two rooms, because it depends on
how loud the source was. ISO 14257 therefore works with the **sound
distribution value**, Equation (1): the level at a position, less the sound
power level of the source that produced it.

$$
D_j(r) = L_{p,j}(r) - L_{W,j}
$$

In a free field that quantity is known exactly. A point source over a
reflecting plane gives Equation (2), which is the line every measured curve is
read against:

$$
D_{\mathrm{ref}}(r) = 20 \lg \frac{r_0}{r} - 11 \ \mathrm{dB}
$$

with $r_0 = 1$ m. The 11 dB is $10 \lg (4 \pi r_0^2)$, rounded.

```python
from phonometry import room

distances = [2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 12.0, 16.0, 24.0, 32.0, 48.0]
levels = [98.9, 95.1, 93.0, 92.0, 91.0, 87.9, 85.8, 83.5, 81.5, 77.0, 75.6]

d = room.sound_distribution_value(levels, 110.8)
print(d[:3].round(1))                                       # [-11.9 -15.7 -17.8]
print(room.reference_distribution_value([2.0, 4.0]).round(2))  # [-17.02 -23.04]
```

At 2 m the measured curve is already 5 dB above the free field, and the gap
grows with distance: that is the room, holding the level up long after the
direct sound has fallen away.

## 2. Two descriptors, and what each of them is for

Clause 6 reads two numbers off the curve, over a stated distance range.

**DL2, the rate of spatial decay per distance doubling**, Equation (5), is the
slope: the least-squares fit of $D$ against $\lg r$, converted from a decade to
a doubling and signed so that a decay is positive. A free field gives 6 dB. Any
room gives less, and how much less is the useful number.

**DLf, the excess over a free field**, Equations (6) to (8), is the height: how
far above open air the room sits. It is what tells a designer that a hall is
10 dB noisier than it needs to be at the far workstations.

```python
res = room.spatial_decay_curve(d, distances, region="middle", far_limit_m=24.0)
print(round(res.decay_rate_db, 2))    # 4.73 dB per doubling
print(round(res.mean_level_excess, 2))   # 7.33 dB
print(res.region)                     # middle
```

The two answer different design questions and they do not substitute for each
other. A room can decay steeply and still be loud, and a room with a healthy
absorbed ceiling can be quiet at the near workstations and decay hardly at all
past them.

The distance ranges are 6.2: **near** from 1 m to $d_1$, **middle** from $d_1$
to $d_2$, **far** beyond $d_2$, with 5 m and 16 m the typical pair. The middle
region is the one occupational work reads, and the clause asks for it to reach
24 m whenever the room is big enough, which is what `far_limit_m` above does.

```python
print(room.distance_region(12.0))         # middle
print(room.typical_decay_range("middle")) # (2.0, 5.0)
print(room.typical_excess_range("middle"))# (2.0, 10.0)
```

Those last two ranges are ISO 11690-3, 4.3: what a workroom usually gives. A
middle-range DL2 of 4.7 dB per doubling and an excess of 7.3 dB put this hall
inside both.

## 3. Where the numbers come from

![Section through a factory hall. A test source sits on the floor at least three metres from the wall, and a dashed path runs from it parallel to the floor at one metre fifty-five, with ten measurement points marked at two, three, four, six, eight, twelve, sixteen, twenty-four, thirty-two and forty-eight metres. One microphone on a stand and one standing person are drawn on the path, and the last point keeps one and a half metres of clearance from the far wall. Under the floor, three boxes mark the near, middle and far regions with d1 at five metres and d2 at sixteen. Two boxes at the foot carry the rate of spatial decay and the excess over a free field](https://docs.jmrp.io/phonometry/media/diagram_workroom_path.svg)

The path is 5.3.1: parallel to the floor, beginning on the source, at 1.55 m
for a standing workplace or 1.2 m for a seated one, with no obstacle on the
floor below it and nothing large within 1.5 m of either side. The points are
one of the two distributions 5.3.2 recommends, and the one used here is the
logarithmic one, which is what makes a least-squares fit against $\lg r$
sensible in the first place.

### How the measurement goes

Put the source where a machine would stand, with its acoustical centre either
on the floor or at least 0.5 m above it, and at least 3 m from any wall or
other reflecting object. Run it and check the margin over the background at
every position and in every one of the six octave bands from 125 Hz to 4 kHz:
10 dB or more needs no correction, between 6 dB and 10 dB takes the ISO 3744
correction, and under 6 dB there is no measurement to make. Walk the path from
the source outwards, taking a band spectrum at each of the recommended
distances, measured from the acoustical centre rather than from the cabinet.
Stop the last point at least 1.5 m short of any wall. Then, if the room allows
it, walk a second path at right angles to the first: one path describes a
direction, and two describe a room. Record the path height, the source
position, and any obstacle you could not avoid, because the report is what
makes the curve reproducible.

The margin is a judgement the library will make for you, one octave band at a
time, and it says which of the three cases each position falls in rather than
correcting anything: the correction 5.1.4 asks for between 6 dB and 10 dB is
the one ISO 3744 prints, and applying it here would move a measured level
behind your back.

```python
check = room.check_background_margin([80.0, 70.0, 66.0], 60.0)
print(check.margins_db)        # [20. 10.  6.]
print(check.unusable)          # [False False  True]
print(check.passes)         # False
```

Two other conditions are read where they can be seen rather than asked about. A
region that holds exactly the two positions a regression needs gives a rate that
is the line through them, with nothing left over to check either position
against, and 5.3.2 calls the count of its recommended distributions a minimum.
And `level_excess_at` reading the fitted line outside the distances it was
fitted over is an extrapolation, which is what the 30 m of 6.4.3 asks of a path
that stopped at 24 m. Both emit `SpatialDecayWarning`, so a result that came
out of one of them says so.

The source itself has to qualify first. Annex A asks for more than ISO 6926:
its directivity index must stay inside ± 2 dB up to 630 Hz, rising to ± 8 dB at
1 kHz and holding there to 5 kHz, its spectrum may not step more than 8 dB
between adjacent one-third octaves, and its output must be stable to 0.5 dB
over the measurement.

```python
print(room.omnidirectionality_tolerance(630.0))   # 2.0
print(room.omnidirectionality_tolerance(800.0))   # 5.0
print(room.omnidirectionality_tolerance(1000.0))  # 8.0
```

The 800 Hz value is a reading rather than a quotation: the clause says the
tolerance rises "linearly" between 630 Hz and 1 kHz without saying linear in
what, and the band index is the only reading on which both endpoints land on
printed bands.

## 4. Taking the source's own curve back out

Close to the source, a good part of what the microphone hears is not the room:
it is the source's own directivity and the reflection off the floor under it.
Annex B removes both. It measures the same source over a reflecting plane
outdoors or in a large room, then swaps that measured curve for the theoretical
one of Equations (B.2) to (B.4):

$$
D_{\mathrm{floor,ref}}(r) = D_{\mathrm{ref}}(r)
+ 10 \lg \left( 1 + \frac{r^2}{r^2 + 4 h_\mathrm{S} h_\mathrm{P}} \right) \ \mathrm{dB}
$$

which for a source on the floor becomes the flat 3 dB of a half space.
Equation (B.1) then does the swap in energy.

```python
free_field = [98.8, 94.7, 92.3, 90.3, 88.7, 86.1, 82.6, 79.8, 75.7, 73.7, 67.8]
reference = room.sound_distribution_value(free_field, 110.8)
corrected = room.corrected_distribution_value(d, reference, distances)

fixed = room.spatial_decay_curve(corrected, distances, region="middle", far_limit_m=24.0)
print(round(fixed.decay_rate_db, 2))    # 4.39 dB per doubling
print(round(fixed.mean_level_excess, 2))   # 6.73 dB
```

The correction moves the slope by 0.3 dB per doubling and the level by 0.6 dB,
which is the general shape of it: it tilts a curve a little and shifts it a
lot, because it is largest where the measurement starts.

That difference is also how the library found an error in the annex. Annex C
prints 4.4 dB per doubling for this band and range, which is the **corrected**
figure, and 7.3 dB of excess, which is the **uncorrected** one. Applying the
correction to one descriptor and not to the other cannot be right, and 28 of
the 36 printed results in the annex leave their own rounding if the two are
swapped. The registry entry is in
[Errata](https://docs.jmrp.io/phonometry/reference/errata/).

## 5. One number for six bands

Six octave bands are six numbers, and a report often wants one. Equation (3)
weights the curve by the spectrum of the machine that will actually stand
there, and Equation (4) fixes that spectrum as A-weighted pink noise, Table 1,
so that two rooms can be compared without a machine in mind.

```python
by_band = [-11.9, -13.6, -12.5, -11.9, -12.4, -13.6]   # 125 Hz to 4 kHz
print(round(room.normalized_distribution_value(by_band), 2))   # -12.58
```

Clause 4.2.3 says why the fixed spectrum is a normalisation and not an average
machine: the spectra met in industry are too varied for an average of them to
mean anything.

## 6. From measurement to design

ISO 11690-3 is the other half of the subject: predicting, before the hall is
built, the curve ISO 14257 would measure in it. It sorts the ways of doing that
into four categories, one diffuse-field and three geometrical, and pairs each
with the level of detail it has to be fed.

```python
print(room.prediction_method("2b").family)          # geometrical
print(room.ROOM_DETAIL_LEVELS[1])
# the volume and the mean absorption coefficient of the surfaces

print(room.check_prediction_detail("1", room_detail=3,
                                   fitting_detail=3, source_detail=1).passes)   # False
print(room.check_prediction_detail("2b", room_detail=3,
                                   fitting_detail=3, source_detail=1).passes)   # True
```

Table E.1 reads in both directions, which is the useful part. A reader with
nothing but a volume and one mean absorption coefficient is limited to the
diffuse-field method, and a reader who wants to trace rays over the real shape
of the room has to go and gather a description at that level of detail first.

The fittings are part of the room, and 6.2.2 measures them by density,
$q = S/4V$, the surface of everything standing in the hall over four times its
volume. Annex C then answers the narrower question of what the room adds at the
workstation of the machine itself.

```python
print(round(room.fitting_density(480.0, 1200.0), 2))    # 0.1
print(round(room.workstation_level(sound_power_level=95.0,
                                   emission_level=85.0,
                                   absorption_area=200.0), 2))   # 85.79
print(round(room.total_workstation_level([86.0, 83.0, 80.0]), 2))   # 88.44
```

The increase is $10 \lg (1 + 4S/A)$, with $S$ the area the machine's own
emission implies. It is small in a well-absorbed hall and large in a bare one,
and it is the term that turns a catalogue of quiet machines into a noisy
workshop.

## What this guide covers

- **Covered.**

  - **ISO 14257:2001**: the sound distribution value of Equation (1) and the
    free-field reference of Equation (2); the single numbers of Equations (3)
    and (4) with the Table 1 weightings; the rate of spatial decay of
    Equation (5); the excess of Equations (6), (7) and (8) with the evaluation
    distances of 6.4.3; the distance ranges of 6.2; the source requirements of
    Annex A; the correction of Annex B, Equations (B.1) to (B.4); and the
    conditions of clause 5 as constants.
  - **ISO 11690-3:1998**: the detail levels of Tables 1, 2 and 3; the four
    categories of Table 4 with the pairing of Table E.1; the typical ranges of
    4.3; the fitting density of 6.2.2; and the workstation increase of Annex C.
  - The worked example of Annex C of ISO 14257 is reproduced band by band in the
    [conformance evidence](https://docs.jmrp.io/phonometry/reference/conformance/).

- **Not covered.**

  - Predicting the curve itself. ISO 11690-3 describes what a prediction method
    must model and how much detail it needs; it does not print one, and neither
    ray tracing nor a radiosity solver is implemented here.
  - The reverberation-room calibration of the source, which is ISO 6926 and
    ISO 3741, and the directivity survey of Annex A, which needs a turntable
    rather than a formula.
  - The full reporting checklist of clause 7, which is a list of what a report
    says rather than a quantity to compute.

## See also

- [Open-Plan Office Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/open-plan-acoustics/):
  the same shape of measurement, a line of positions and a spatial decay rate,
  asked about speech rather than about machinery.
- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): what a room
  does to a decay in time, which is the other half of the description.
- [Image Sources and the Steady-State Room Field](https://docs.jmrp.io/phonometry/buildings/rooms/room-image-sources/):
  the room constant and the critical distance, the classical model this
  measurement so often contradicts.
- [Suspended Ceilings](https://docs.jmrp.io/phonometry/materials/absorbers/suspended-ceilings/):
  the product test code behind the absorption a workroom ceiling is sold on.
- [Errata](https://docs.jmrp.io/phonometry/reference/errata/): the Annex C correction defect
  described above, with the page it was read on, and the two constants of
  Equations (5) and (8), the printed 0.3 against $\lg 2$: one conversion
  written twice to different precision.
- API reference: [`room.spatial_decay`](https://docs.jmrp.io/phonometry/reference/api/rooms/spatial-decay/)
  and [`room.workroom_prediction`](https://docs.jmrp.io/phonometry/reference/api/rooms/workroom-prediction/).

## References

- **International Organization for Standardization. (1998).** *Acoustics — Recommended practice for the design of low-noise workplaces containing machinery — Part 3: Sound propagation and noise prediction in workrooms* (ISO 11690-3:1998).
  What to expect of the two descriptors (4.3), the four categories of prediction method of Table 4, the detail levels of Tables 1 to 3 with the pairing of Table E.1, and the workstation increase of Annex C.
- **International Organization for Standardization. (2001).** *Acoustics — Measurement and parametric description of spatial sound distribution curves in workrooms for evaluation of their acoustical performance* (ISO 14257:2001).
  The measurement and the two descriptors: the sound distribution value of Equation (1), the free-field reference of Equation (2), the single numbers of Equations (3) and (4), the rate of spatial decay of Equation (5), the excess of Equations (6) to (8), the distance ranges of 6.2, the source requirements of Annex A and the correction of Annex B. Read from BS EN ISO 14257:2001.
- **International Organization for Standardization. (2010).** [*Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering methods for an essentially free field over a reflecting plane*](https://www.iso.org/standard/52055.html) (ISO 3744:2010).
  The background-noise correction ISO 14257 calls for when the margin falls between 6 dB and 10 dB.
- **International Organization for Standardization. (2012).** [*Acoustics — Measurement of room acoustic parameters — Part 3: Open plan offices*](https://www.iso.org/standard/46520.html) (ISO 3382-3:2012).
  The same idea for speech in an office: a line of positions, a rate of spatial decay, and a level at a fixed distance.
- **International Organization for Standardization. (2016).** *Acoustics — Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels* (ISO 6926:2016).
  The calibration of the source, which Annex A of ISO 14257 then tightens for directivity and stability.